VS513Z Hot Sheet

 Balboa Instruments
 System PN 55839-01

 System Model # VSP-VS513Z-YCAH
 Software Version # 43
 EPN # 2720


 Base PCBA - PN 55840-01
 PCB VS500Z - PN 22972 Rev D

 Base Panels
 VL400 – PN 55129




 Template used: 40600_P.pdf 01/07/2008
 55839-01_97_A.pdf 02/21/2008



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                             55839-01_97_A
System Revision History
System PN EPN           Date      Requested By                             Changes Made
55839        2532    08.01.2007   Balboa         Production release
55839        2566    08.24.2007   Balboa         Update to v41 software, Blower and P2 now 120V
55839        2531    09.20.2007   Balboa         Software set back to v39
55839        2531    10.17.2007   Balboa         Correction to SSID page 6
55839        2531    10.29.2007   Balboa         System now 48A - YCAH
55839-01     2720    02.21.2008   Balboa         Software update to v43




      http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                      Page 2                                      920-925-3094
                                                                                                       55839-01_97_A
Basic System Features and Functions

 Power Requirements



 System Outputs
 Setup 1 (As Manufactured)




 Optional Devices




                                                                                                                             FUSE
 Additional Options                             K8                                   W2
                                                                                                          K5
                                                                              W3
                                                                     J1 J1A
                                                                                                                      J10



                                                                            J2A
                                                                                                                            J18




                                                                                                          2 3
                                                                                                     1
                                                                                                U4       J12

                                                     J2



                                                                                                                            J13
                                                                                         BALBOA INSTRUMENTS, INC. 2-SPD
                                                  J60      J22                       J44 VS500Z                   EXT RLY
                                                                    J7       J8
                                                                                         P/N 22972 REV D


                                                 EXT.     AUX. F                     VAC MADE IN U.S.A
                                                 RLY               SEN. A   SEN. B        COPYRIGHT 2005




http://www.MyPoolSpas.com    Wholesale Pool and Spa Parts
                                       Page 3                                                                   920-925-3094
                                                                                                                     55839-01_97_A
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                       Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                                 three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                                        a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                                         configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                                  “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                         “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                        “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                  TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                          J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                   PUMP                  OZONE
                               K1                                                                                                                                                                                                                      J23                 J29
                                                                                                                                                                F1                                                                                                                                                                        F5, F3A 250V                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                   G




                                                                                                                                                                                                                                                                      G




                                                                                                                                                                                                                                                                                           K5
                                                                                                                                                                                              J90




                                                                                                                                                                                                                                                                                                                                                                       G     C
                                                                                                                                                                                                                                                   C




                                                                                                                                                                                                                                                                      C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                              J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                                               J12
                              W1                                                        K8                                                     K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                          K4      K1
                                                                                                                                                                                                                                                   SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                                                J18
                                                                                                                                                                                                                                                         F2                                                                                                           U4
                                                                                                                                                                                                                                                                                                                                               J13




                                                                                                                    J2A                                                                                       T0.25A 250V
                                                                                                                                                                                                                                                   NEUTRAL
                                                                                                                                                                                                                                                                      WHT AC                                                                                                     J1
                                                                                                                                                                     J18




                                                                                                                                                                                                    W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                               K3
                                                                                                                                         U4   J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                           VS100
                                                                                                                                                                                                                      P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                            J26                                                                                                 F4
                                                                                                                                                                                                                  Balboa




                                                                             J43
                                                                                                                                                                                                                                 © 2006




                         F2                                                                                                                                                                 LINE
                                                                                                                                                                                                                                                                                      K2




                                                                                                                                                                     J13                                                                                                                                            TST             RST
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                     S1                    J6 J43
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                                       J7          J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                 J9




                                                                            S1 TST       EXT.
                                                                                           T      AUX. F                      VAC MADE IN U.S.A
                                                                                                                              V
                                                           SWITCHBANK A                  RLY
                                                                                          L                SEN. A   SEN. B         COPYRIGHT 2005                                                                                                            HEATER
                                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                                                                            SWITCHBANK A                      SEN. A     SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                                                  Page 4                                                                                                                                                             920-925-3094
                                                                                                                                                                                                                                                                                                                                          55839-01_97_A
Wiring Configuration and DIP Settings
          Setup 1 (As Manufactured)


                                                                                                                                            PCBA Rev D & E only.                                         Ozone and Circ Pump must be same voltage.
                                                                                                                                            Black jumper required.                                       DIP switch Circ Pump mustifbe same voltage.
                                                                                                                                                                                                         Ozone and A9 must be ON Circ Pump is installed.
                                                                                                                                            Do not remove.                                               Do not remove Fuse F7 (20A)
                                                                                                                                       K1                                                            F7 FUSE 20A 250V                                   J47




                                                                                                                                                                                                                                               J46
                                                                                                                                                                                          W10                                                                               J29
               CLASS G FUSE 30A                                  BLK AC                                K6 J23                                                         J50
                                                      F5           J61    J62                                                J74




                                                                                                                                                                                                                                                    Circ.Pump
                                                                                                                                                                                                                                                                                                     F1




                                                                                                                                                                  Audio Visual
                                                                                                             2-Spd P1
                                                                                                                                                                                                                                                                                              J20




                                                                                                                                                                                                    J17/26




                                                                                                                                                                                                                                                                          Ozone
                                                                                                                                                                                           Blower




                                                                                                                                                                                                                                                                                                           FUSE 3A 250V
                                           WHT AC
                                             T




                                                                                                                                                                                                                                                                                                C
                                                                                                                              J73




                                                                                                                                                                                                                                                                                             Light
                                                                                                                                                                                                                                                          C




                                                                                                                                                                                                                                                                                   C


                                                                                                                                                                                                                                                                                             12V
                                                                                                                    C




                                                                                                                                                                                               C
                                                                                                                                                                          C




                                                                                                                                                                                                                                                          G




                                                                                                                                                                                                                                                                                               G
                                                                                                                                                                                                                                                                                   G
                                                                                                                                                                                                        W7




                                                                                                                                                     W4
                                                                                                                    G




                                                                                                                                                                                               G
                                                                                                                                                                          G
                             J11    J15    J16 J25 J63 J64
               J66 J65
                                                                                                                             W1                                                                                   K8                                                                K5
                                                                                                                                                                                                                                                          W2
                                                                                                                                                         T1                                             K9                                      W3
                                          NEUTRAL




                                                                                           F4 FUSE .3A 250V
                                                                                                                                                                                                                                       J1 J1A
                                           WHITE




                                                                                                                                                                                                                                                                                                     J10
                                          BLACK
                                           HOT




                                                                                                                                                                                                                                              J2A
                                                                                                                                                                                                                                                                         VS51x mode




                                                                                                                                                                                                                                                                                                           J18
                   TORQUE
                   RANGE
                                          RED
                                          HOT




                                                                                                                                                                                                                                                                                       2 3
                   FOR TB1:                                                                                             K3                                                                                                                                                     1
          K4       27-30 IN. LBS.                                                                                                                                                                                                                                         U4       J12
                                                                                                                        K2
                                                                         TB1                                                                                                                                           J2
                                     J32 J33 J34          J35                                                                                                                                          J43

                                     J36            J37                                                                 F2
                                           RED AC                                                                                                                                                                                                                                                         J13
                                                                                                                                                                                                                                                                    BALBOA INSTRUMENTS, INC. 2-SPD
                                                                                                                                                                                                                   J60       J22                                J44 VS500Z                   EXT RLY
                                                                                                                                                                                                                                      J7       J8

                     Balboa                                 HTR2                HTR1                                                                                                                         J6
                                                                                                                                                              E.GND




                                                                                                                                                                                                                                                                    P/N 22972 REV D


                            J100                                   J101                                                                                                                               S1 TST       EXT.     AUX. F                          VAC MADE IN U.S.A
                                                                                                                                                                                     SWITCHBANK A                  RLY               SEN. A   SEN. B                COPYRIGHT 2005


                                                                                            Heater rated @ 240V
                                                                5.5 kW                      (Approx. 1.4kW @ 120V)
                                                                                                                                                     X-P231
                                                                                                                                                     PN 53681                                                          J7
                                                                                                    J1
                                                                                                         1-Spd P2
                                                                                                         R




                                                                                                                                                      P/N 22909 REV B
                                                                                                  W1
                                                                                                           B




                                                                                                                                                                                     J6
                                                                                                             W  G




                                                                                                                                       F30A 480V




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                                VS51x/VS5xxS/VS5xxD
  SSID #                                                                                                                                             Compatible
                                                                                                                                                                                                                            Wiring Color Key
                                                                                                                                                                                                                                                                   120 Volt Connections
    100                                                                                                                                        J12                                                                                                                 240 Volt Connections
    69                                                                                                                                                    1                      2         3                                                                       Black AC Jumpers
    43                                                                                                                                                                                                                                                             12 Volt Connections
                   A1, Test Mode OFF
                                                                                                                                                                                                                                                                   Relay Control Wires
                   A2, Mode changes allowed A7, See Table 1
                                                                                                                                                      J43                                                                   Board Connector Key
                                                                                                                                                                                 Memory
                                                                                  A9, Non-Circ Mode
                   A5, 2-speed P1                                                                                                                                                Reset                                      1              Typically Line voltage
                                                                                  A10, See Table 1
                                                                                                                                                                                                                            2              Typically Line voltage for 2-speed pumps
   Panel Button Assignments                                                                            Panel Button Positions                                                                                               3              Neutral (Common)
   1=Pump 2+J17/26                 3=Temp                                                                                                       1                                                                           4              Ground
   2=Pump 1                        4=Light                                             1      2                     3              4                                                 3
                                                                                                                                                4    2
                                                                                                                                                                                                                                           Note flat sides in connector


       http://www.MyPoolSpas.com                                                                         Wholesale Pool and Spa Parts
                                                                                                                   Page 5                                                                                                                                               920-925-3094
                                                                                                                                                                                                                                                                             55839-01_97_A
DIP Switches and Jumpers Definitions
   SSID 100 69 43                                                                  Base Model VS513Z
DIP Switch Key
     A1 Test Mode (normally OFF)
     A2 “ON” position: Standard mode only
         “OFF” position: Std/Ecn/Sleep mode changes allowed
     A3 “ON” position: use Mini Panel
         “OFF” position: use Digital Duplex or Light Duplex panel
     A4 Aux Freeze (must be OFF)
 A5+A9 Pump 1 speeds and Circ Modes:
             A5       A9     Circ Mode                                         Pump 1 Speed
            OFF       OFF    Non-circ                                          2-speed
            ON        OFF    Circ "acts like Pump 1 low" (filters/polls/ect)   1-speed
            OFF       ON     24 hours with 3°F shut-off                        1-speed
            ON        ON     24 hours with 3°F shut-off                        2-speed            Table 1         # of Hi-Speed
                                                                                                                  Pumps/Blower
     A6 “ON” position: 50Hz operation                                                                          Before Heat Disabled
          “OFF” position: 60Hz operation                                                          A7        A10
A7+A10 Control amp draw requirements (See Table 1)
     A8 “ON” position: temperature is displayed in degrees Celsius                                OFF       OFF           0
          “OFF” position: temperature is displayed in degrees Fahrenheit                          ON        OFF           1
Note: Panel layout is always Pump 2+J17/26, Pump 1, Temp, Light                                   OFF       ON            2
                                                                                                  ON        ON            3

Jumper Key
J12     Factory set. DO NOT MOVE.
        Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software.
        Jumper must be on Pins 2 and 3 for VS50xZ software.
J43     When jumper is placed on 2 pins during power-up, system will reset persistent memory.
        Leave on 1 pin only to enable persistent memory feature.
 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this hot sheet.



                                        Panel Button Positions
                                                                                         1
                        A3: OFF        1        2                    3         4                   3
                                                                                         4    2


                        A3:ON                           1       2      3       4



                                    Panel Button Assignments
                                     1=Pump 2+J17/26                  3=Temp
                                     2=Pump 1                         4=Light



 http://www.MyPoolSpas.com                           Wholesale Pool and Spa Parts
                                                               Page 6                                             920-925-3094
                                                                                                                       55839-01_97_A
Ozone Connections
Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or
240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover
of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2
connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the
required voltage.

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ
pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage
is selected.

Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone
generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next
to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in place.
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.

 Balboa Ozone connector configuration for 120V 60Hz                                                B
                                           Line - Black conductor
                    Use this slot for the leftover Red conductor
      Common - Install the White conductor here for 120V ozone
                                                                                                         G
                                      Ground (Green) conductor

                                                                                        Flat sides of sockets as shown
 Balboa Ozone connector configuration for 240V 60Hz                                                B
                                           Line - Black conductor
                   Use this slot for the leftover White conductor
        Common - Install the Red conductor here for 240V ozone
                                                                                                         G
                                       Ground (Green) conductor



FUSE 20A 250V               J47
                      J46




                                     J29
                                                                          Line - Black conductor
                         Circ.Pump
                              R




                                              J20     F1                  Use this slot for the leftover conductor
                              B




                                                                          Common - Red for 240V or White for 120V ozone (See W2 wire)
                                                                          Ground (Green) conductor
                                                           FUSE 3A 250V
                                               W
                                             Light
                              W




                                             12V




                                                                          W2 wire determines voltage
                                               W
                              G




 K8                                     K5
                              W2
                       W3
                J1 J1A
                                                     J10


       http://www.MyPoolSpas.com                     Wholesale Pool and Spa Parts
                                                               Page 7                                                920-925-3094
                                                                                                                          55839-01_97_A
Duplex Panel Configurations
SETUP 1




          VL400
          PN 55129 with Overlay PN 11822
           Connects to Main Board terminal J1 or J2
           Requires software v38 or higher.




                http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                                Page 8               920-925-3094
                                                                                          55839-01_97_A

More Related Content

What's hot (17)

56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj
 
55106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_3055106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah
 
54751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-3054751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-30
 

Viewers also liked (7)

85 0063-a rev 6-eco-2 operation_web
85 0063-a rev 6-eco-2 operation_web85 0063-a rev 6-eco-2 operation_web
85 0063-a rev 6-eco-2 operation_web
 
K100 techbook en
K100 techbook enK100 techbook en
K100 techbook en
 
85 0065-a rev 6-deluxe operation_web
85 0065-a rev 6-deluxe operation_web85 0065-a rev 6-deluxe operation_web
85 0065-a rev 6-deluxe operation_web
 
Horizonseries catalog rev1b
Horizonseries catalog rev1bHorizonseries catalog rev1b
Horizonseries catalog rev1b
 
K600 techbook menu_en
K600 techbook menu_enK600 techbook menu_en
K600 techbook menu_en
 
K200 techbook en
K200 techbook enK200 techbook en
K200 techbook en
 
85 0064-c rev 2-9300 troubleshooting
85 0064-c rev 2-9300 troubleshooting85 0064-c rev 2-9300 troubleshooting
85 0064-c rev 2-9300 troubleshooting
 

Similar to Balboa VS513Z Hot Sheet System Specs (14)

56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
55415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-3055415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-30
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
55508 vsp vs501_sz_azaj
55508 vsp vs501_sz_azaj55508 vsp vs501_sz_azaj
55508 vsp vs501_sz_azaj
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

Balboa VS513Z Hot Sheet System Specs

  • 1. VS513Z Hot Sheet Balboa Instruments System PN 55839-01 System Model # VSP-VS513Z-YCAH Software Version # 43 EPN # 2720 Base PCBA - PN 55840-01 PCB VS500Z - PN 22972 Rev D Base Panels VL400 – PN 55129 Template used: 40600_P.pdf 01/07/2008 55839-01_97_A.pdf 02/21/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 55839-01_97_A
  • 2. System Revision History System PN EPN Date Requested By Changes Made 55839 2532 08.01.2007 Balboa Production release 55839 2566 08.24.2007 Balboa Update to v41 software, Blower and P2 now 120V 55839 2531 09.20.2007 Balboa Software set back to v39 55839 2531 10.17.2007 Balboa Correction to SSID page 6 55839 2531 10.29.2007 Balboa System now 48A - YCAH 55839-01 2720 02.21.2008 Balboa Software update to v43 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 55839-01_97_A
  • 3. Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) Optional Devices FUSE Additional Options K8 W2 K5 W3 J1 J1A J10 J2A J18 2 3 1 U4 J12 J2 J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 P/N 22972 REV D EXT. AUX. F VAC MADE IN U.S.A RLY SEN. A SEN. B COPYRIGHT 2005 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 55839-01_97_A
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 F5, F3A 250V J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 TST RST BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J6 J43 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. T AUX. F VAC MADE IN U.S.A V SWITCHBANK A RLY L SEN. A SEN. B COPYRIGHT 2005 HEATER A SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 55839-01_97_A
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) PCBA Rev D & E only. Ozone and Circ Pump must be same voltage. Black jumper required. DIP switch Circ Pump mustifbe same voltage. Ozone and A9 must be ON Circ Pump is installed. Do not remove. Do not remove Fuse F7 (20A) K1 F7 FUSE 20A 250V J47 J46 W10 J29 CLASS G FUSE 30A BLK AC K6 J23 J50 F5 J61 J62 J74 Circ.Pump F1 Audio Visual 2-Spd P1 J20 J17/26 Ozone Blower FUSE 3A 250V WHT AC T C J73 Light C C 12V C C C G G G W7 W4 G G G J11 J15 J16 J25 J63 J64 J66 J65 W1 K8 K5 W2 T1 K9 W3 NEUTRAL F4 FUSE .3A 250V J1 J1A WHITE J10 BLACK HOT J2A VS51x mode J18 TORQUE RANGE RED HOT 2 3 FOR TB1: K3 1 K4 27-30 IN. LBS. U4 J12 K2 TB1 J2 J32 J33 J34 J35 J43 J36 J37 F2 RED AC J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 Balboa HTR2 HTR1 J6 E.GND P/N 22972 REV D J100 J101 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 Heater rated @ 240V 5.5 kW (Approx. 1.4kW @ 120V) X-P231 PN 53681 J7 J1 1-Spd P2 R P/N 22909 REV B W1 B J6 W G F30A 480V WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) VS51x/VS5xxS/VS5xxD SSID # Compatible Wiring Color Key 120 Volt Connections 100 J12 240 Volt Connections 69 1 2 3 Black AC Jumpers 43 12 Volt Connections A1, Test Mode OFF Relay Control Wires A2, Mode changes allowed A7, See Table 1 J43 Board Connector Key Memory A9, Non-Circ Mode A5, 2-speed P1 Reset 1 Typically Line voltage A10, See Table 1 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Pump 2+J17/26 3=Temp 1 4 Ground 2=Pump 1 4=Light 1 2 3 4 3 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 55839-01_97_A
  • 6. DIP Switches and Jumpers Definitions SSID 100 69 43 Base Model VS513Z DIP Switch Key A1 Test Mode (normally OFF) A2 “ON” position: Standard mode only “OFF” position: Std/Ecn/Sleep mode changes allowed A3 “ON” position: use Mini Panel “OFF” position: use Digital Duplex or Light Duplex panel A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: A5 A9 Circ Mode Pump 1 Speed OFF OFF Non-circ 2-speed ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed OFF ON 24 hours with 3°F shut-off 1-speed ON ON 24 hours with 3°F shut-off 2-speed Table 1 # of Hi-Speed Pumps/Blower A6 “ON” position: 50Hz operation Before Heat Disabled “OFF” position: 60Hz operation A7 A10 A7+A10 Control amp draw requirements (See Table 1) A8 “ON” position: temperature is displayed in degrees Celsius OFF OFF 0 “OFF” position: temperature is displayed in degrees Fahrenheit ON OFF 1 Note: Panel layout is always Pump 2+J17/26, Pump 1, Temp, Light OFF ON 2 ON ON 3 Jumper Key J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this hot sheet. Panel Button Positions 1 A3: OFF 1 2 3 4 3 4 2 A3:ON 1 2 3 4 Panel Button Assignments 1=Pump 2+J17/26 3=Temp 2=Pump 1 4=Light http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 55839-01_97_A
  • 7. Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone G Ground (Green) conductor Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone G Ground (Green) conductor FUSE 20A 250V J47 J46 J29 Line - Black conductor Circ.Pump R J20 F1 Use this slot for the leftover conductor B Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor FUSE 3A 250V W Light W 12V W2 wire determines voltage W G K8 K5 W2 W3 J1 J1A J10 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 55839-01_97_A
  • 8. Duplex Panel Configurations SETUP 1 VL400 PN 55129 with Overlay PN 11822 Connects to Main Board terminal J1 or J2 Requires software v38 or higher. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 55839-01_97_A