Ultimate spaside instruction sheet

789 views

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
789
On SlideShare
0
From Embeds
0
Number of Embeds
46
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Ultimate spaside instruction sheet

  1. 1. Temperature Display: Press the Program key. Press the List key until TuF or TuC is displayed. Press the Enter key to show the current setting F or C. Use the Up/Down arrows to adjust the parameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Time of Day: Press the Program key. Press the List key until the time 12:00 is displayed. Press the Enter key to show the current setting. Use the Up/Down arrows to adjust the parameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Economy Mode Start Time: Press the Program key. Press the List key until ECon is displayed. Press the Enter key to show the current setting. Use the Up/Down arrows to adjust the parameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Economy Mode Duration: Press the Program key. Press the List key until ECdu is displayed. Press the Enter key to show the current setting of OFF to 24:00 (always active). Use the Up/Down arrows to adjust the parameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Panel Lock: Press the Program key. Press the List key until Loc is displayed. Press the Enter key to show the current setting of On or OFF. Use the Up/Down arrows to adjust the parameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Note: Once the spaside panel has been locked, Loc will appear in the display. To Unlock theDefault System Operation: When power is applied, or there is a temporary loss of power, spaside panel the user must follow this procedure. Press the Program Key (Loc will appear). Press (in this order): Up Arrow Key, Pump 1 Key and the Light Key. The Loc will disappear.the system will initiate its default programming. The filter cycle will begin 24-hours after the system hasbeen powered up. The filtration cycle will be active for 1-hour and will repeat every 24-hours. Thetemperature will be maintained at 95BF. Economy Mode: The Economy mode allows the set point to be reduced by 20BF, without actually changing the set temperature. This mode can be programmed using the Program Key, or it can be overridden by using the Economy Key. Whenever the Economy key is used, the Pump 1 Key: Press this key once to turn Pump 1 on. A second press will turn it off. Economy programming is overridden (forced on or off, toggled each time the key is pressed) untilFor dual speed pump operation; Press this key once to turn Pump 1 onto Low speed, press this key a midnight of the current day. At this time, the override is cancelled and standard operation will beginsecond time to turn Pump 1 onto High speed, a third press will turn the pump off. A built-in timer will again. When in Economy Mode the Economy Icon will appear in the display window.shut the pump off after 20 minutes of operation unless done so manually. The Pump 1 Icon will appearon the LCD while the pump is running in High speed and flash while it is in Low speed. If the filter iconappears, a filtration cycle has begun and you will not be able to turn the pump off. Freeze Protection: If the spa water temperature drops below 59BF the “Smart Winter Mode” will be activated for a period of 24-hours.If the pump has not been activated in the last 2-hours it will be turned for a period of 1-minute. This frequency will decrease as the temperature drops. If the spa water temperature drops to 49BF the pump and heater will be activated until the spa water temperature reaches 50BF. While in this second mode of freeze protection, control over the spa will be disabled until the water has heated sufficiently. The Filtration indicator will be illuminated while in this Pump 2 Key: Press this key once to turn Pump 2 on. A second press will turn it off. mode of operation.For dual speed pump operation; Press this key once to turn Pump 2 onto Low speed, press this key asecond time to turn Pump 2 onto High speed, a third press will turn the pump off. A built-in timer will High Temperature: If the spa water temperature exceeds 115BF at the high-limit sensor 3shut the pump off after 20 minutes of operation unless done so manually. The Pump 2 Icon will appear flashing dots will appear below the temperature display and the heater will be turned off. During thiswhile the pump is running in High speed and flash while it is in Low speed. time all other outputs (pump, light etc.) will continue to operate. If the spa water temperature exceeds 122BF at the high-limit sensor the heater and all outputs will be disabled. Once the spa water has cooled it will be necessary to cycle power to the spa off then on again to reset the system for normal use. Accessory/List Key: Press this key to turn blower or accessory on and off. Ifequipped with a multiple speed blower; press this key once to turn blower onto High speed, a secondpress will turn the blower onto Low speed and a third press will turn the blower off. A built-in timer will Error Identification & Serviceshut the pump off after 20 minutes of operation unless done so manually. The Accessory Icon willappear while the blower is running in High speed and flash while it is in Low speed. Light/Enter Key: Press this key to turn the light onto its highest intensity, a secondpress will turn the light onto medium, a third press will turn the light onto low and a fourth press will turn If 3 flashing dots appear below the temperature display an error and a need for service has occurred.it off. If equipped with Fiber Optic: Press this key once to show “L1”. Use the Up arrow key to turn the (Contact Your Local Dealer for Service)light onto High, Medium, Low and Off. Press the light key a second time, “F1” will appear. Use the Uparrow key to turn the Fiber Optic wheel and light on, Fiber Optic wheel off with light on and both Off.The light will automatically shut off after 2 hours. The Light Icon will appear while the light is on. If the actual spa water temperature greatly differs from the displayed temperature or the display reads a constant 33BF, a temperature sensor error and a need for service has occurred. (Contact Your Local Temperature Set Keys: Press the Up arrow key to increase the Dealer for Service)desired temperature. Press the Down arrow key to decrease the temperature. The temperature can beadjusted in 1BF increments from 59BF to 104BF (5BC to 40BC). The new setting will remain on the displayfor 5 seconds as a confirmation. During this time the Set Point icon will be appear to let you know this isthe desired and not the actual temperature. After 5 seconds the display will return to the currenttemperature reading. When the temperature drops to 1BF below the set temperature, the heater will beturned on until the temperature is 1BF above the set temperature. The heater icon will appear while theheater is on and flash when there is a call for heat and the heater has not yet been activated. If 3 flashing below the temperature display and the temperature displayed is 115BF ro higher, and over temperature condition and a need for service has occurred. (Contact Your Local Dealer for Service) NOTE: If you notice the pump coming on for seemingly no reason throughout the day, the Programming Parameters: There are 7 parameters that may be programmed. system may be in “Smart Winter Mode”. If you cannot control some functions of the spa beFollow these procedures to set each parameter: (1) Press and hold the Program Key for 5-seconds sure to check to see if the Filtration indicator is illuminated. The spa may be in the midst of auntil the program icon appears. (2) Press the List (Accessory) Key until the parameter to be modified is filtration cycle. Freeze Protection and Over temperature condition will also limit or disable spadisplayed. (3) Once the parameter is displayed, press the Enter (Light) Key to show the current setting. functions.(4) Use the Up/Down arrows to adjust the setting. (5) Once the parameter has been adjusted, press theEnter (Light) Key to confirm the change. The display will then revert back to the Temperature/Timemode. Repeat these steps as needed to modify each parameter.Filtration Start Time: Press the Program key. Press the List key until Flon is displayed. Pressthe Enter key to show the current setting 12:00. Us the Up/Down arrows to adjust the parameter. Pressthe Enter key to confirm the change and return to the Temp/Time mode.Filtration Duration: Press the program key. Press the List key until Fldu is displayed. Press theEnter key to show the current setting OFF to 12:00 (constant). Use the Up/Down arrows to adjust the http://www.MyPoolSpas.comparameter. Press the Enter key to confirm the change and return to the Temp/Time mode. Wholesale Pool and Spa Parts 920-925-3094 85-0042 Rev.7 09.07.01

×