1. GS510DZ Tech Sheet
Balboa Instruments
System PN 55106
System Model # GS5-GS510DZ-RCA-3.0
Software Version # 36
EPN # 2125
Base PCBA - PN 55107
PCB GS500Z - PN 22015 Rev B
Base Panels
VL801D (Serial Deluxe) – PN 54108
Template used: 40599_M.pdf 04/16/2008
55106_97_B.pdf 05/02/2008
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 1 920-925-3094
55106_97_B
2. System Revision History
System PN EPN Date Requested By Changes Made
55106 2125 10.20.2006 Balboa New system
55106 n/a 05.02.2008 Balboa Main PCB update to rev B
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 2 920-925-3094
55106_97_B
3. Basic System Features and Functions
Power Requirements
Requires PCB Rev B.
System Outputs
Setup 1 (As Manufactured)
(Stereo)
Optional Devices
Additional Options J71
J2A J1A
J1
J2
1
J18
J10
U4
J19
J12
J60 J7 J8 J44
1 1 1 1 1
J22
1
EXT RLY AUX F SEN A SEN B VAC J11
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 3 920-925-3094
55106_97_B
5. Wiring Configuration and DIP Settings
Setup 1 (As Manufactured) HIPot Testing Note:
Disconnect slip terminal with green
wires from J90 prior to performing
HiPot test. Failure to disconnect may
cause a false failure of the test.
(Stereo) Reconnect terminal to J90 after
successful completion of HiPot test.
AV F7 F1 J13
J50 J29 J23 K6 K1 F10A 250V
OZONE PUMP 1 K9
F3A 250V
J52 J51 F6, T30A 480V
J
Audio Visual
G N
J46
Blower
2-Spd P1
1-Spd P1
Ozone
J47
CIRC. PUMP
K8
K5 J20
Circ Pump
N
J25
5 G N C9 Spa
N
N
G N
J32
2 Light
G
G
G
F3
TB1 10VAC
10VAC
J17/26 J72
1 F4, T0.2A 250V OPT. BLWR/PUMP 2 J71
T1
J58
J2A J1A
2 J1
W2
J28
8
J2
3
J26
6
K3
1
J18
4 J43 J10
K4
U4
J57
F2
Balboa
J19
HTR2 J101 HTR1 00 K2 S1
W1 J90 J12
BALBOA INSTRUMENTS, IN J60 J7 J8 J44
J6
GS5xxDZ mode
E.GND
GS500Z 1 1 1 1 1
COPYRIGHT 2007
J22
MADE IN U.S.A. TST 1
P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11
Heater rated @ 240V 3.0kW
J11 must be Jumpered
3.0 kW
J6
K2
1-Spd P2
R B W G
J2
J4 W12
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
GS51x/GS5xxS/GS5xxD
Compatible Wiring Color Key
SSID # J12 3 Neutral (Common) AC Connections
J11
100 3.0kW 2
Special AC Connections
99 Heater Line AC Connections
1
36 10 Volt Connections
A1, Test Mode OFF A6, 50 Hz Relay Control Wires
A2, N/A A7, J17/26 Disabled
Enabled J43
A3, Off-board Pump disabled A8, Degrees C
enabled Board Connector Key
Memory
Reset 1 Typically Line voltage
A10, High Amp mode
Low Amp mode 2 Typically Line voltage for 2-speed pumps
Panel Button Assignments Panel Button Positions 3 Neutral (Common)
1=Time 5=Light 4 Ground
1 3 8 5
2=Mode/Prog 6=Pump 1
3=Temp Up 7=Unused
7=Pump 2 2 4 6 7 Note flat sides in connector
4=Temp Down 8=Unused
8=J17/26
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 5 920-925-3094
55106_97_B
6. DIP Switches and Jumpers Definitions
SSID 100 99 36 Base Model GS500DZ-GS501DZ-GS510DZ
DIP Switch Key
A1 . . . . . . . . . . . . . . . . Test Mode (normally Off)
A2 . . . . . . . . . . . . . . . . N/A
A3 . . . . . . . . . . . . . . . . In “ON” position, off-board pump enabled
. . . . . . . . . . . . . . . . In “OFF” position, off-board pump disabled
A4 . . . . . . . . . . . . . . . . Aux Freeze (must be OFF)
A5 . . . . . . . . . . . . . . . . In “ON” position, Two-speed pump 1
. . . . . . . . . . . . . . . . In “OFF” position, One-speed pump 1 (A9 must be On and a circ pump installed)
A6 . . . . . . . . . . . . . . . . In “ON” position, 50Hz operation
. . . . . . . . . . . . . . . . In “OFF” position, 60Hz operation
A7 . . . . . . . . . . . . . . . . In “ON” position, J17/26 equipment enabled
. . . . . . . . . . . . . . . . In “OFF” position, J17/26 equipment disabled
A8 . . . . . . . . . . . . . . . . In “ON” position, temperature is displayed in degrees Celsius
. . . . . . . . . . . . . . . . In “OFF” position, temperature is displayed in degrees Fahrenheit
A9 . . . . . . . . . . . . . . . . In “ON” Position, 24 Hour Circ Pump with 3ºF shut off
. . . . . . . . . . . . . . . . In “OFF” position, no circ pump
A10 . . . . . . . . . . . . . . . . In “ON” Position, heater is disabled while any high-speed pump or blower is running (low amperage mode)
. . . . . . . . . . . . . . . . In “OFF” position, heater can run while any/all high-speed pumps or blowers are running (high amperage mode)
Jumper Key
J11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2.
If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only.
J12 Factory set. DO NOT MOVE.
Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software.
Jumper must be on Pins 2 and 3 for GS50xZ software.
J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory.
Leave on 1 pin only to enable persistent memory feature.
WARNING:
Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
Panel Button Positions Aux Panel Information
1 3 8 5
Supports 2-button aux panel
2 4 6 7 VX20 6 7
Supports 4-button aux panel
Panel Button Assignments VX40D 6 7 8 5
1=Time 5=Light
2=Mode/Prog 6=Pump 1
3=Temp Up 7=Pump 2 (when A3 is ON)
4=Temp Down 8=J17/26 (when A7 is ON)
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 6 920-925-3094
55106_97_B
7. Electrical Service Configuration Options
Systems with PCB Rev B Only J50
AV
J29
OZONE
J23
PUMP 1 K9
K6 K1
F7
F10A 250V
F1 J13
J52 J51 F6, T30A 480V
J F3A 250V
G N
J46
Single Service, TN and TT Electrical Systems
J47
CIRC. PUMP
K8
K5 J20
N
J25
5 G N C9
N
N
J32
2 (1 x 16 Amp or 1 x 32 Amp) G N
G
G
G
F3
TB1 10VAC
3 Wires (1 Line + 1 Neutral + 1J71Protective Earth)
10VAC
J17/26 J72
1 F4, T0.2A 250V OPT. BLWR/PUMP 2
T1
J58
Protective Earth wire (Green/Yellow) must be connected
to system ground terminal as marked.
J2A J1A
AS MANUFACTURED
2 J1
W2
J28
8 This option is configured and shipped as the default.
J2
L1 3
J26
6
K3
All equipment (pumps, blower, and heater) runs on
N1 service line L1. J18
1
4 J43 J10
K4
U4
J57
F2
Balboa
J19
BALBOA INSTRUMENTS, INC.
W1
HTR2 J101 HTR1 00 K2
J90 Systems using only 1 DIP switch (A10) for heat disable:
S1
J6
J60 J7 J8 J44
J12
E.GND
1 1
GS500Z
COPYRIGHT 2007 Pb
Pb
For 1 x 16 Amp Service: 1 1 1
J22
MADE IN U.S.A. TST 1
P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11
DIP Switch A10 must be ON.
For 1 x 32 Amp Service:
Set DIP Switch A10 such that total system amperage
draw never exceeds rated service input.
Systems using multiple DIP switches for heat disable:
Refer to system Hot Sheet DIP Switch Definition page
and set the switches shown in Table 1 such that total
system amperage draw never exceeds rated service input.
AV F7 F1 J13
J50 J29 J23 K6 K1 F10A 250V
OZONE PUMP 1 K9
J52 J51 F6, T30A 480V
J F3A 250V
G N
J46
Dual Service, TN and TT Electrical Systems
J47
CIRC. PUMP
K8
K5 J20
N
J25
5 G N C9
(2 x 16 Amp)
N
N
G N
J32
2
G
G
G
F3
TB1
1 F4, T0.2A 250V
5 Wires (2 Lines10VAC 2 Neutrals + 1 Protective Earth)
J17/26 +
J72
OPT. BLWR/PUMP 2
J71
10VAC
L2 T1
Protective Earth wire (Green/Yellow) must be connected
J58
to system ground terminal as marked.
J2A J1A
N2 2 J1
W2
J28
8 The heater runs on service line L1, while all other
J2
OPTIONAL
L1 3
equipment, such as pumps and blowers, run on
J26
6
K3
service line L2.
N1 J18
1
4 J43 J10
K4
J57 Completely remove the white wire from J26 and J32.
F2
U4
Balboa
J19
BALBOA INSTRUMENTS, INC.
W1
HTR2 J101 HTR1 00 K2
J90 Note: J32 and J25 are electrically identical. The white
S1
J6
J60 J7 J8 J44
J12
E.GND
1 1
GS500Z
COPYRIGHT 2007 Pb
Pb
wire may be attached to either terminal before removal. 1 1 1
J22
MADE IN U.S.A. TST 1
P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11
Systems using only 1 DIP switch (A10) for heat disable:
DIP Switch A10 must be OFF.
Systems using multiple DIP switches for heat disable:
Refer to system Hot Sheet DIP Switch Definition page
and set both switches shown in Table 1 to ON positions.
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts
Page 7 920-925-3094
55106_97_B