SlideShare a Scribd company logo
1 of 8
Download to read offline
VS500Z 120V GFCI Tech Sheet

 Balboa Instruments
 System PN 54337-04

 System Model # VSP-VS500Z-FCAH
 Software Version # 43
 EPN # 2720


 Base PCBA - PN 54369-03
 PCB VS500Z - PN 22972 Rev D

 Base Panels
 VL200 (Mini bath) – PN 52487




 Template used: 40600_P.pdf 01/07/2008
 54337-04_97_A.pdf 02/13/2008



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                             54337-04_97_A
System Revision History
System PN EPN           Date      Requested By                             Changes Made
54337-01     1801    05.29.2006   Balboa         New system
54337-02     2570    09.24.2007   Balboa         Software update to v38
54337-03     2720    02.13.2008   Balboa         Software update to v43
54337-04     N/A     01.23.2009   Balboa         Replace GFCI 25101 with 30536. Ref. Eco #6821




      http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                      Page 2                                     920-925-3094
                                                                                                      54337-04_97_A
Basic System Features and Functions

 Power Requirements



 System Outputs
 Setup 1 (As Manufactured)



              (Stereo)


 Optional Devices




                                                                                                                                  FUSE
 Additional Options                                  K8                                   W2
                                                                                                               K5
                                                                                   W3
                                                                          J1 J1A
    and Spa-only Dolphin Remote                                                                                            J10



                                                                                 J2A
                                                                                                                                 J18




                                                                                                               2 3
                                                                                                          1
                                                                                                     U4       J12

                                                          J2



                                                                                                                                 J13
                                                                                              BALBOA INSTRUMENTS, INC. 2-SPD
                                                       J60      J22                       J44 VS500Z                   EXT RLY
                                                                         J7       J8
                                                                                              P/N 22972 REV D


                                                      EXT.     AUX. F                     VAC MADE IN U.S.A
                                                      RLY               SEN. A   SEN. B        COPYRIGHT 2005




http://www.MyPoolSpas.com         Wholesale Pool and Spa Parts
                                            Page 3                                                                   920-925-3094
                                                                                                                          54337-04_97_A
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                             Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                              Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                         Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                          ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                               which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                   three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                          a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                           configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                    “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                           “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                          as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                          function as a 1 kW heater at 120VAC.)
                                                                                                                                                                          “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                       At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                       Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                       the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                       Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                    TST                              RST
                                                                                  FUSE 20A 250V                         J47                                                                                                                                                                 J6 J43
                                                                                                                J46




                                                                       F7                                                            J29
            K6   J23                                 J50                                                                                                                                                                     PUMP                  OZONE
                               K1                                                                                                                                                                                                        J23                 J29
                                                                                                                                                           F1                                                                                                                                                                             J20
                                                                                                                                                   J20
                                                                        J17/26




                                                                   J6
  E.GND




                                                                                                                                                                                                                                     G




                                                                                                                                                                                                                                                        G




                                                                                                                                                                                                                                                                             K5
                                                                                                                                                                                J90




                                                                                                                                                                                                                                                                                                                                      G     C
                                                                                                                                                                                                                                     C




                                                                                                                                                                                                                                                        C
                                                                                                                                                                 50V
                                                                                                                                                    C
                                                                                                                        C




                                                                                                                                         C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                        G




                                                                                                                                                    G
                                                                                                                                         G




                                                                                                                                                                                J50




                                                                            W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                J12
                              W1                                                   K8                                                    K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                  K9                               W3
                                                                                                                        W2                                                                 K4      K1
                                                                                                                                                                                                                                     SWITCHBANK A
                                                                                                        J1 J1A
                                                                                                                                                          J10
                                                                                                                                                                                                                                                                                                                               J18
                                                                                                                                                                                                                                           F2                                                                                        U4
                                                                                                                                                                                                                                                                                                                J13




                                                                                                               J2A                                                                              T0.25A 250V
                                                                                                                                                                                                                                     NEUTRAL
                                                                                                                                                                                                                                                        WHT AC                                                                                  J1
                                                                                                                                                                J18




                                                                                                                                                                                      W1                                        J58        J57
                                                                                                                                     1       2 3
                         K3                                                                                                                                                                                                                                 K3
                                                                                                                                   U4    J12
                         K2
                                                                                        J2
                                                                                                                                                                                                                             VS100
                                                                                                                                                                                                        P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                              J26                                                                                                 F4
                                                                                                                                                                                                    Balboa




                                                                            J43
                                                                                                                                                                                                                   © 2006




                         F2                                                                                                                                                   LINE
                                                                                                                                                                                                                                                                        K2




                                                                                                                                                                J13
                                                                                                                                                                             BLK AC
                                                                                                                             BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                            S1
                                                                                              J22                        J44 VS500Z                   EXT RLY
                                                                                                       J7        J8                                                                                                                                                                                             J7        J8
                                             E.GND




                                                                                                                             P/N 22972 REV D
                                                                                                                                                                                                                                                                   J9




                                                                                             AUX. F                      VAC MADE IN U.S.A
                                                                                                                         V
                                                           SWITC                                      SEN. A   SEN. B        COPYRIGHT 2005                                                                                                    HEATER
                                                                                                                                                                                                                                                 A
                                                                                                                                                                                                                                                                                              S                SEN. A   SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                            J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                             Wholesale Pool and Spa Parts
                                                                                                                                                             Page 4                                                                                                                                        920-925-3094
                                                                                                                                                                                                                                                                                                                54337-04_97_A
Wiring Configuration and DIP Settings
            Setup 1 (As Manufactured)
                                                                                                                  (Stereo)




                                                     BLK
                                                                      GFCI
                                             WHT
                                                                    GRN                   AC PWR IN                                            PCBA Rev D & E only.
                                                                                                                                                                                                      Ozone and Circ Pump must be same voltage.
                                                                                                                                               Black jumper required.
                                                                                                                                                                                                      Do not remove Fuse F7 (20A)
                                                                                                                                               Do not remove.
                                                                                                                                          K1                                                      F7 FUSE 20A 250V                                   J47




                                                                                                                                                                                                                                            J46
                                                                                                                                                                                     W10                                                                                 J29
                         CLASS G FUSE 30A                                  BLK AC                              K6 J23                                                  J50
                                                                F5           J61    J62                                            J74




                                                                                                                                                                                                                                                 Circ.Pump
                                                                                                                                                                                                                                                                                                  F1




                                                                                                                                                                   Audio Visual
                                                                                                                   2-Spd P1                                                                                                                                                                J20




                                                                                                                                                                                                 J17/26




                                                                                                                                                                                                                                                                       Ozone




                                                                                                                                                                                                                                                                                                        FUSE 3A 250V
                                                     WHT AC
                                                       T




                                                                                                                                                                                                                                                                                             C
                                                                                                                                    J73




                                                                                                                                                                                                                                                                                          Light
                                                                                                                                                                                                                                                       C




                                                                                                                                                                                                                                                                                C


                                                                                                                                                                                                                                                                                          12V
                                                                                                                        C




                                                                                                                                                                                          C
                                                                                                                                                                           C




                                                                                                                                                                                                                                                       G




                                                                                                                                                                                                                                                                                            G
                                                                                                                                                                                                                                                                                G
                                                                                                                                                                                                     W7




                                                                                                                                                        W4
                                                                                                                        G




                                                                                                                                                                                          G
                                                                                                                                                                           G
                                       J11    J15    J16 J25 J63 J64
                         J66 J65
                                                                                                                                   W1                                                                          K8                                                                K5
                                                                                                                                                                                                                                                       W2
                                                                                                                                                          T1                                         K9                                      W3
                                                    NEUTRAL




                                                                                                     F4 FUSE .3A 250V                                                                                                                      J1A
                                                     WHITE




                                                                                                                                                                                                                                    J1
                                                                                                                                                                                                                                                                                                  J10
DIP A10 must
be ON and
                                                    BLACK
                                                     HOT




jumper added                                                                                                                                                                                                                               J2A
for 120V systems.
                                                                                                                                                                                                                                                                      VS50x mode




                                                                                                                                                                                                                                                                                                        J18
                             TORQUE
Remove for                   RANGE
                                                    RED
                                                    HOT




240V Systems.                FOR TB1:                                                                                         K3                                                                                                                                            1
                                                                                                                                                                                                                                                                                    2 3

                    K4       27-30 IN. LBS.                                                                                                                                                                                                                            U4       J12
                                                                                                                              K2
                                                                                   TB1                                                                                                                              J2
                                               J32 J33 J34          J35                                                                                                                             J43

                                               J36            J37                                                             F2
                                                     RED AC                                                                                                                                                                                                                                            J13
                                                                                                                                                                                                                                                                 BALBOA INSTRUMENTS, INC. 2-SPD
                                                                                                                                                                                                                J60       J22                                J44 VS500Z                   EXT RLY
                                                                                                                                                                                                                                   J7       J8

                               Balboa                                 HTR2                HTR1                                                                                                            J6
                                                                                                                                                               E.GND




                                                                                                                                                                                                                                                                 P/N 22972 REV D


                                      J100                                   J101                                                                                                                  S1 TST       EXT.     AUX. F                          VAC MADE IN U.S.A
                                                                                                                                                                                  SWITCHBANK A                  RLY               SEN. A   SEN. B                COPYRIGHT 2005


                                                                                                      Heater rated @ 240V
                                                                          5.5 kW                      (Approx. 1.4kW @ 120V)




 WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
 WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)


   SSID #                                                                                                                                  VS50x Compatible                                                Wiring Color Key
                                                                                                                                                                                                                                           120 Volt Connections
      100                                                                                                                                J12                                                                                               240 Volt Connections
      61                                                                                                                                           1     2                3
                                                                                                                                                                                                                                           Black AC Jumpers
      43                                                                                                                                                                                                                                   12 Volt Connections
                    A1, Test Mode OFF
                    A2, Un, P1, TE, LT                                                                                                                                                                                                     Relay Control Wires
                                                                          A7, Mode changes allowed
                    A3, Mini Panel                                                                                                                J43
                                                                                                                                                                                                           Board Connector Key
                                                                                                                                                          Memory
                                                                          A9, Non-Circ Mode
                    A5, 2-speed P1                                                                                                                        Reset                                            1
                                                                          A10, High Amp mode
                                                                               Low Amp mode                                                                                                                               Typically Line voltage
                                                                                                                                                                                                           2              Typically Line voltage for 2-speed pumps
     Panel Button Assignments                                                                          Panel Button Positions
                                                                                                                                                                                                           3              Neutral (Common)
     1=Unused             3=Temp                                                                                                         1
                                                                                                                                                                                                           4
     2=Pump 1             4=Light                                                  1             2            3    14 2                 3 4                  3                                                            Ground
                                                                                                                                         4  2
                                                                                                                                                                                                                          Note flat sides in connector


          http://www.MyPoolSpas.com                                                                     Wholesale Pool and Spa Parts
                                                                                                                  Page 5                                                                                                                          920-925-3094
                                                                                                                                                                                                                                                       54337-04_97_A
DIP Switches and Jumpers Definitions
   SSID 100 61 43                                                                  Base Model VS500Z
DIP Switch Key
     A1 Test Mode (normally OFF)
     A2 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up *
         “OFF” position: Button layout will be: Unused, Pump 1, Temp, Light
     A3 “ON” position: use Mini Panel *
         “OFF” position: use Lite Duplex or Digital Duplex panel
     A4 Aux Freeze (must be OFF)
 A5+A9 Pump 1 speeds and Circ Modes:
             A5        A9     Circ Mode                                        Pump 1 Speed
             OFF      OFF    Non-circ                                          2-speed
             ON       OFF    Circ "acts like Pump 1 low" (filters/polls/ect)   1-speed
             OFF      ON     24 hours with 3°F shut-off                        1-speed
             ON       ON     24 hours with 3°F shut-off                        2-speed
     A6 “ON” position: 50Hz operation
          “OFF” position: 60Hz operation
     A7 “ON” position: Standard mode only
          “OFF” position: Std/Ecn/Sleep mode changes allowed
     A8 “ON” position: temperature is displayed in degrees Celsius
          “OFF” position: temperature is displayed in degrees Fahrenheit
    A10 “ON” position: heater is disabled while any high-speed pump is running (low amperage mode)
          “OFF” position: heater can run while any/all high-speed pumps are running (high amperage mode)
* Panels with button layout         are not compatible when A2 or A3 is ON.
Note: No blower or second pump available on VS500Z model. If additional output is required, use VS501Z or higher.
Jumper Key
J12     Factory set. DO NOT MOVE.
        Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software.
        Jumper must be on Pins 2 and 3 for VS50xZ software.
J43     When jumper is placed on 2 pins during power-up, system will reset persistent memory.
        Leave on 1 pin only to enable persistent memory feature.
 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this hot sheet.

                                           Panel Button Positions
                                                                                         1
                            A3: OFF       1        2                   3       4                      3
                                                                                         4    2


                            A3:ON                          1      2      3     4



                                        Panel Button Assignments
                                        1=Unused                       3=Temp
                            A2: OFF 2=Pump 1                           4=Light

                            A2:ON       1=Pump 1                       3=Temp Down
                                        2=Light                        4=Temp Up
 http://www.MyPoolSpas.com                             Wholesale Pool and Spa Parts
                                                                 Page 6                                             920-925-3094
                                                                                                                         54337-04_97_A
Ozone Connections
Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or
240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover
of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2
connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the
required voltage.

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ
pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage
is selected.

Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone
generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next
to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in place.
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.

 Balboa Ozone connector configuration for 120V 60Hz                                                B
                                           Line - Black conductor
                    Use this slot for the leftover Red conductor
      Common - Install the White conductor here for 120V ozone
                                                                                                         G
                                      Ground (Green) conductor

                                                                                        Flat sides of sockets as shown
 Balboa Ozone connector configuration for 240V 60Hz                                                B
                                           Line - Black conductor
                   Use this slot for the leftover White conductor
        Common - Install the Red conductor here for 240V ozone
                                                                                                         G
                                       Ground (Green) conductor



FUSE 20A 250V               J47
                      J46




                                     J29
                                                                          Line - Black conductor
                         Circ.Pump
                              R




                                              J20     F1                  Use this slot for the leftover conductor
                              B




                                                                          Common - Red for 240V or White for 120V ozone (See W2 wire)
                                                                          Ground (Green) conductor
                                                           FUSE 3A 250V
                                               W
                                             Light
                              W




                                             12V




                                                                          W2 wire determines voltage
                                               W
                              G




 K8                                     K5
                              W2
                       W3
                J1 J1A
                                                     J10


       http://www.MyPoolSpas.com                     Wholesale Pool and Spa Parts
                                                               Page 7                                                920-925-3094
                                                                                                                          54337-04_97_A
Duplex Panel Configurations
SETUP 1




          VL200 (Mini Panel)
          PN 52487 with Overlay PN 11219
           Connects to Main Panel terminal J1




                http://www.MyPoolSpas.com       Wholesale Pool and Spa Parts
                                                          Page 8               920-925-3094
                                                                                    54337-04_97_A

More Related Content

What's hot (17)

55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj
 
55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah
 
54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah
 
55666 vsp vs525_bcah
55666 vsp vs525_bcah55666 vsp vs525_bcah
55666 vsp vs525_bcah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj
 
55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah
 
54650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-3054650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-30
 
54517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-3054517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-30
 
55461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-3055461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-30
 
54648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-3054648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-30
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 

Similar to 54337 0420 vsp_vs500z_fcah (16)

54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
55399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_3055399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_30
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_2055509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
 
54511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-3054511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-30
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
55248 02 gs5_gs501_sz_rca-20
55248 02 gs5_gs501_sz_rca-2055248 02 gs5_gs501_sz_rca-20
55248 02 gs5_gs501_sz_rca-20
 
54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

54337 0420 vsp_vs500z_fcah

  • 1. VS500Z 120V GFCI Tech Sheet Balboa Instruments System PN 54337-04 System Model # VSP-VS500Z-FCAH Software Version # 43 EPN # 2720 Base PCBA - PN 54369-03 PCB VS500Z - PN 22972 Rev D Base Panels VL200 (Mini bath) – PN 52487 Template used: 40600_P.pdf 01/07/2008 54337-04_97_A.pdf 02/13/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 54337-04_97_A
  • 2. System Revision History System PN EPN Date Requested By Changes Made 54337-01 1801 05.29.2006 Balboa New system 54337-02 2570 09.24.2007 Balboa Software update to v38 54337-03 2720 02.13.2008 Balboa Software update to v43 54337-04 N/A 01.23.2009 Balboa Replace GFCI 25101 with 30536. Ref. Eco #6821 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 54337-04_97_A
  • 3. Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) (Stereo) Optional Devices FUSE Additional Options K8 W2 K5 W3 J1 J1A and Spa-only Dolphin Remote J10 J2A J18 2 3 1 U4 J12 J2 J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 P/N 22972 REV D EXT. AUX. F VAC MADE IN U.S.A RLY SEN. A SEN. B COPYRIGHT 2005 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 54337-04_97_A
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C 50V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J22 J44 VS500Z EXT RLY J7 J8 J7 J8 E.GND P/N 22972 REV D J9 AUX. F VAC MADE IN U.S.A V SWITC SEN. A SEN. B COPYRIGHT 2005 HEATER A S SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 54337-04_97_A
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) (Stereo) BLK GFCI WHT GRN AC PWR IN PCBA Rev D & E only. Ozone and Circ Pump must be same voltage. Black jumper required. Do not remove Fuse F7 (20A) Do not remove. K1 F7 FUSE 20A 250V J47 J46 W10 J29 CLASS G FUSE 30A BLK AC K6 J23 J50 F5 J61 J62 J74 Circ.Pump F1 Audio Visual 2-Spd P1 J20 J17/26 Ozone FUSE 3A 250V WHT AC T C J73 Light C C 12V C C C G G G W7 W4 G G G J11 J15 J16 J25 J63 J64 J66 J65 W1 K8 K5 W2 T1 K9 W3 NEUTRAL F4 FUSE .3A 250V J1A WHITE J1 J10 DIP A10 must be ON and BLACK HOT jumper added J2A for 120V systems. VS50x mode J18 TORQUE Remove for RANGE RED HOT 240V Systems. FOR TB1: K3 1 2 3 K4 27-30 IN. LBS. U4 J12 K2 TB1 J2 J32 J33 J34 J35 J43 J36 J37 F2 RED AC J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 Balboa HTR2 HTR1 J6 E.GND P/N 22972 REV D J100 J101 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 Heater rated @ 240V 5.5 kW (Approx. 1.4kW @ 120V) WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # VS50x Compatible Wiring Color Key 120 Volt Connections 100 J12 240 Volt Connections 61 1 2 3 Black AC Jumpers 43 12 Volt Connections A1, Test Mode OFF A2, Un, P1, TE, LT Relay Control Wires A7, Mode changes allowed A3, Mini Panel J43 Board Connector Key Memory A9, Non-Circ Mode A5, 2-speed P1 Reset 1 A10, High Amp mode Low Amp mode Typically Line voltage 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Unused 3=Temp 1 4 2=Pump 1 4=Light 1 2 3 14 2 3 4 3 Ground 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 54337-04_97_A
  • 6. DIP Switches and Jumpers Definitions SSID 100 61 43 Base Model VS500Z DIP Switch Key A1 Test Mode (normally OFF) A2 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up * “OFF” position: Button layout will be: Unused, Pump 1, Temp, Light A3 “ON” position: use Mini Panel * “OFF” position: use Lite Duplex or Digital Duplex panel A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: A5 A9 Circ Mode Pump 1 Speed OFF OFF Non-circ 2-speed ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed OFF ON 24 hours with 3°F shut-off 1-speed ON ON 24 hours with 3°F shut-off 2-speed A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: Standard mode only “OFF” position: Std/Ecn/Sleep mode changes allowed A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit A10 “ON” position: heater is disabled while any high-speed pump is running (low amperage mode) “OFF” position: heater can run while any/all high-speed pumps are running (high amperage mode) * Panels with button layout are not compatible when A2 or A3 is ON. Note: No blower or second pump available on VS500Z model. If additional output is required, use VS501Z or higher. Jumper Key J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this hot sheet. Panel Button Positions 1 A3: OFF 1 2 3 4 3 4 2 A3:ON 1 2 3 4 Panel Button Assignments 1=Unused 3=Temp A2: OFF 2=Pump 1 4=Light A2:ON 1=Pump 1 3=Temp Down 2=Light 4=Temp Up http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 54337-04_97_A
  • 7. Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone G Ground (Green) conductor Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone G Ground (Green) conductor FUSE 20A 250V J47 J46 J29 Line - Black conductor Circ.Pump R J20 F1 Use this slot for the leftover conductor B Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor FUSE 3A 250V W Light W 12V W2 wire determines voltage W G K8 K5 W2 W3 J1 J1A J10 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 54337-04_97_A
  • 8. Duplex Panel Configurations SETUP 1 VL200 (Mini Panel) PN 52487 with Overlay PN 11219 Connects to Main Panel terminal J1 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 54337-04_97_A