SlideShare a Scribd company logo
1 of 11
Download to read offline
GS501Z Tech Sheet

 Balboa Instruments
 System PN 55509

 System Model # GS5-GS501Z-RCA-2.0
 Software Version # 43
 EPN # 2911


 Base PCBA - PN 55514
 PCB GS500Z - PN 22015 Rev B

 Base Panels
 VL401 (LCD Lite Duplex) – PN 54094
 VL402 (LCD Duplex Digital) – PN 54093

 Optional Panels
 VL200 (Mini bath) – PN 52144
 VL240 (MVP240) – PN 53643
 VL260 (MVP260) – PN 53645




 Template used: 40599_M.pdf 04/16/2008
 55509_97_B.pdf 07/15/2008



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                                55509_97_B
System Revision History
System PN EPN             Date      Requested By                             Changes Made
54511          2911 07.15.2008 Balboa              New system based on 54511-01, with 2kW heater
54511          2911 07.21.2008 Balboa              Corrected Base PCBA - PN




        http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                        Page 2                                     920-925-3094
                                                                                                           55509_97_B
Basic System Features and Functions
 Power Requirements




                                                                                     Requires PCB Rev B.



 System Outputs
 Setup 1 (As Manufactured)




              (Stereo)


 Optional Devices




  Additional Options                                                                                                       J71


     and Spa-only Dolphin Remote
                                                                                           J2A J1A




                                                       J1


                                                       J2




                                                                                                                                                          1
                                                                                                                                                    J18
                                                       J10
                                                                                                                       U4

                                                                                                                                        J19


                                                                                                                                  J12
                                                       J60                          J7               J8          J44
                                                                 1             1             1               1         1
                                                                 J22




                                                                                                                                        1
                                                       EXT RLY         AUX F       SEN A             SEN B       VAC        J11

http://www.MyPoolSpas.com          Wholesale Pool and Spa Parts
                                             Page 3                                                                                           920-925-3094
                                                                                                                                                      55509_97_B
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                       Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                                 three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                                        a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                                         configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                                  “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                         “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                        “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                  TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                          J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                   PUMP                  OZONE
                               K1                                                                                                                                                                                                                      J23                 J29
                                                                                                                                                                F1                                                                                                                                                                        F5, F3A 250V                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                   G




                                                                                                                                                                                                                                                                      G




                                                                                                                                                                                                                                                                                           K5
                                                                                                                                                                                              J90




                                                                                                                                                                                                                                                                                                                                                                       G     C
                                                                                                                                                                                                                                                   C




                                                                                                                                                                                                                                                                      C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                              J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                                               J12
                              W1                                                        K8                                                     K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                          K4      K1
                                                                                                                                                                                                                                                   SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                                                J18
                                                                                                                                                                                                                                                         F2                                                                                                           U4
                                                                                                                                                                                                                                                                                                                                               J13




                                                                                                                    J2A                                                                                       T0.25A 250V
                                                                                                                                                                                                                                                   NEUTRAL
                                                                                                                                                                                                                                                                      WHT AC                                                                                                     J1
                                                                                                                                                                     J18




                                                                                                                                                                                                    W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                               K3
                                                                                                                                         U4   J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                           VS100
                                                                                                                                                                                                                      P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                            J26                                                                                                 F4
                                                                                                                                                                                                                  Balboa




                                                                             J43
                                                                                                                                                                                                                                 © 2006




                         F2                                                                                                                                                                 LINE
                                                                                                                                                                                                                                                                                      K2




                                                                                                                                                                     J13                                                                                                                                            TST             RST
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                     S1                    J6 J43
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                                       J7          J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                 J9




                                                                            S1 TST       EXT.
                                                                                           T      AUX. F                      VAC MADE IN U.S.A
                                                                                                                              V
                                                           SWITCHBANK A                  RLY
                                                                                          L                SEN. A   SEN. B         COPYRIGHT 2005                                                                                                            HEATER
                                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                                                                            SWITCHBANK A                      SEN. A     SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                                                  Page 4                                                                                                                                                             920-925-3094
                                                                                                                                                                                                                                                                                                                                             55509_97_B
Wiring Configuration and DIP Settings
               Setup 1 (As Manufactured)                                                                                                                                                          HIPot Testing Note:
                                                                                                                                                                                                  Disconnect slip terminal with green
                                                                                                                                                                                                  wires from J90 prior to performing
                                                                                                                                                                                                  HiPot test. Failure to disconnect may
                                                                                         (Stereo)                                                                                                 cause a false failure of the test.
                                                                                                                                (optional)                                                        Reconnect terminal to J90 after
                                                                                                                                                                                                  successful completion of HiPot test.



                                                           AV                                                                                                                                                               F7                                                             F1   J13
                                          J50                                       J29                 J23                             K6               K1                                                               F10A 250V
                                                                                    OZONE              PUMP 1             K9
                                                                                                                                                                                                                                                         F3A 250V
J52            J F6, T30A 480V
               J51
                                                  Audio Visual
                                                   G N




                                                                                                                                                                    Blower
                                                                                                                                                                                             J46
                                                                                                      2-Spd P1
                                                                                                      1-Spd P1
                                                                                    Ozone
                                            J47




                                                                CIRC. PUMP
                                                                                                                                                                                                  K8
                                                                                                                                                                                                                                         K5          J20
                                                  Circ Pump




                                                                                                                                                                       N
                        J25
                          5                        G N                                                                                                                                                                             C9                                     Spa
                                                                                       N




                                                                                                          N

                                                                                                                                                                                                                                                                          G   N
                        J32
                          2                                                                                                                                                                                                                                               Light




                                                                                                                                                                       G
                                                                                      G




                                                                                                         G



                                                                                                                                                                                                                                                               F3
                                    TB1                                                                                                                                                      10VAC




                                                                                                                                                                                                                                                                                10VAC
                                                                                                                                                                    J17/26                   J72
                          1                            F4, T0.2A 250V                                                                                               OPT. BLWR/PUMP 2                                                                                J71
                                                                                                                               T1
                                                                                              J58




                                                                                                                                                                                                                                   J2A J1A
                          2                                                                                                                                                                  J1
                                                                                         W2
                                                           J28
                                                             8
                                                                                                                                                                                              J2
                          3
                                                                  J26
                                                                    6




                                                                                                                     K3




                                                                                                                                                                                                                                                                                                            1
                                                                                                                                                                                                                                                                                                      J18
                          4                                                                                                                                                            J43   J10
                                                                                                                     K4




                                                                                                                                                                                                                                                               U4
                   J57
                                                                                                                                            F2

      Balboa
                                                                                                                                                                                                                                                                                    J19

                                           HTR2     J101                     HTR1     00                          K2                                S1
                                    W1                                                                                    J90                                                                                                                                                 J12
      BALBOA INSTRUMENTS, INC.                                                                                                                                                                J60                           J7               J8          J44
                                                                                                                                                                                       J6
                                                                                                                                                                                                                                                                                        GS50xZ mode
                                                                                                                                            E.GND




      GS500Z                                                                                                                                                                                           1             1               1               1         1
      COPYRIGHT 2007           Pb
                               Pb
                                                                                                                                                                                                       J22




      MADE IN U.S.A.                                                                                                                                                                   TST                                                                                          1
      P/N 22015_B                                                                                                                                             SWITCHBANK A                   EXT RLY         AUX F         SEN A             SEN B       VAC        J11



Heater rated @ 240V                                                                                                                                                                                                                                            2.0kW
J11 must not be Jumpered
                                                  2.0 kW




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                    GS501Z
  SSID #                                                                                                                            Software
                                                                                                                                                                                               Wiring Color Key
                                                                                                                 J11            J12     3
                                                                                                                                                                                                                                              Neutral (Common) AC Connections
      100                                                                                           2.0kW                                                                                                                                     Special AC Connections
      63                                                                                            Heater                              2                                                                                                     Line AC Connections
      43                                                                                                                                                                                                                                      10 Volt Connections
                                A1, Test Mode OFF        A6, 50 Hz                                                                      1
                                                                                                                                                                                                                                              Relay Control Wires
                                A2, Mode changes allowed A7, J17/26, P1, TE, LT
                                                                                                                                                         J43
                                                         A8, Degrees C                                                                                   Memory                                Board Connector Key
                                                         A9, Non-Circ Mode                                                                               Reset
                                A5, 2-speed P1           A10, High Amp mode
                                                              Low Amp mode
                                                                                                                                                                                               1                         Typically Line voltage
                                                                                                                                                                                               2                         Typically Line voltage for 2-speed pumps
   Panel Button Assignments                                                                         Panel Button Positions
                                                                                                                                                                                               3                         Neutral (Common)
   1=J17/26                              3=Temp                                                                           1                                                                    4
   2=Pump 1                              4=Light                               1     2                 3         4                                       3                                                               Ground
                                                                                                                          4         2
                                                                                                                                                                                                                         Note flat sides in connector


           http://www.MyPoolSpas.com                                                                 Wholesale Pool and Spa Parts
                                                                                                               Page 5                                                                                                                                    920-925-3094
                                                                                                                                                                                                                                                                 55509_97_B
DIP Switches and Jumpers Definitions
  SSID 100 63 43                                                                 Base Model GS501Z
DIP Switch Key
     A1 Test Mode (normally OFF)                                                                  Alert:
     A2 “ON” position: Standard mode only                                                         Blower or 1-speed Pump 2 is
         “OFF” position: Std/Ecn/Sleep mode changes allowed                                       required, connect to J17/26.
     A3 “ON” position: use Mini Panel *                                                           For no Blower and no Pump 2,
         “OFF” position: use Digital Duplex or Light Duplex panel                                 use GS500Z or GS515Z.
     A4 Aux Freeze (must be OFF)
 A5+A9 Pump 1 speeds and Circ Modes:
             A5       A9     Circ Mode                                         Pump 1 Speed
             OFF      OFF    Non-circ                                          2-speed
             ON       OFF    Circ "acts like Pump 1 low" (filters/polls/ect)   1-speed
             OFF      ON     24 hours with 3°F shut-off                        1-speed
             ON       ON     24 hours with 3°F shut-off                        2-speed
     A6 “ON” position: 50Hz operation
          “OFF” position: 60Hz operation
     A7 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up with J17/26 on 1-button Aux panel **
          “OFF” position: Button layout will be: J17/26, Pump 1, Temp, Light
     A8 “ON” position: temperature is displayed in degrees Celsius
          “OFF” position: temperature is displayed in degrees Fahrenheit
    A10 “ON” position: heater is disabled while any high-speed pump or blower is running (low amperage mode)
          “OFF” position: heater can run while any/all high-speed pumps or blowers are running (high amperage mode)
* Panels with button layout         are not compatible when either A3 or A7 is ON.
** J2 panel connector on Main Board must be a 6-pin connector. IR Receiver is not compatible.

Jumper Key
J11      If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2.
         If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only.
J12      Factory set. DO NOT MOVE.
         Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software.
         Jumper must be on Pins 2 and 3 for GS50xZ software.
J43      When jumper is placed on 2 pins during power-up, system will reset persistent memory.
         Leave on 1 pin only to enable persistent memory feature.

 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this tech sheet.
                                        Panel Button Positions
                                                                                 1
                            A3: OFF     1      2                3      4                      3   A
                                                                                 4       2


                            A3:ON                     1     2    3     4                 A



                                      Panel Button Assignments
                                      1=J17/26                  3=Temp
                            A7: OFF 2=Pump 1                    4=Light

                            A7:ON     1=Pump 1               3=Temp Down          Aux=J17/26
                                      2=Light                4=Temp Up
 http://www.MyPoolSpas.com                           Wholesale Pool and Spa Parts
                                                               Page 6                                         920-925-3094
                                                                                                                      55509_97_B
Electrical Service Configuration Options
                        Systems with PCB Rev B Only                  J50
                                                                                        AV
                                                                                                                 J29
                                                                                                                 OZONE
                                                                                                                                  J23
                                                                                                                                 PUMP 1         K9
                                                                                                                                                            K6            K1
                                                                                                                                                                                                                                                 F7
                                                                                                                                                                                                                                               F10A 250V
                                                                                                                                                                                                                                                                                                                   F1   J13


                           J52            J51 F6, T30A 480V
                                          J                                                                                                                                                                                                                                    F3A 250V
                                                                             G     N
                                                                                                                                                                                                              J46

                                                                                                                                                          Single Service, TN and TT Electrical Systems
                                                                       J47
                                                                                             CIRC. PUMP
                                                                                                                                                                                                                   K8
                                                                                                                                                                                                                                                              K5          J20




                                                                                                                                                                                         N
                                                   J25
                                                     5                       G     N                                                                                                                                                                    C9




                                                                                                                   N




                                                                                                                                   N
                                                   J32
                                                     2                                                                                                    (1 x 16 Amp or 1 x 32 Amp)                                                                                                           G             N




                                                                                                                                                                                        G
                                                                                                                   G




                                                                                                                                  G
                                                                                                                                                                                                                                                                                    F3
                                                               TB1                                                                                                        10VAC
                                                                                                                                                          3 Wires (1 Line + 1 Neutral + 1J71Protective Earth)




                                                                                                                                                                                                                                                                                                     10VAC
                                                                                                                                                                   J17/26 J72
                                                     1                                 F4, T0.2A 250V                                                                                OPT. BLWR/PUMP 2
                                                                                                                                                     T1
                                                                                                                         J58
                                                                                                                                                          Protective Earth wire (Green/Yellow) must be connected
                                                                                                                                                          to system ground terminal as marked.




                                                                                                                                                                                                                                                        J2A J1A
AS MANUFACTURED




                                                     2                                                                                                                                                        J1
                                                                                                                    W2
                                                                                        J28
                                                                                          8                                                               This option is configured and shipped as the default.
                                                                                                                                                                           J2
                  L1                                 3
                                                                                               J26
                                                                                                 6




                                                                                                                                           K3
                                                                                                                                                          All equipment (pumps, blower, and heater) runs on
                  N1                                                                                                                                      service line L1.                                                                                                                                                    J18
                                                                                                                                                                                                                                                                                                                                    1

                                                     4                                                                                                                                                  J43   J10




                                                                                                                                           K4
                                                                                                                                                                                                                                                                                    U4
                                              J57
                                                                                                                                                             F2

                                  Balboa
                                                                                                                                                                                                                                                                                                             J19



                                 BALBOA INSTRUMENTS, INC.
                                                               W1
                                                                     HTR2        J101                     HTR1     00                     K2
                                                                                                                                                J90       Systems using only 1 DIP switch (A10) for heat disable:
                                                                                                                                                                     S1

                                                                                                                                                                                                        J6
                                                                                                                                                                                                               J60                               J7                J8         J44
                                                                                                                                                                                                                                                                                                   J12




                                                                                                                                                             E.GND
                                                                                                                                                                                                                                                          1               1
                                 GS500Z
                                 COPYRIGHT 2007           Pb
                                                          Pb
                                                                                                                                                            For 1 x 16 Amp Service:                                      1                 1                                         1




                                                                                                                                                                                                                             J22
                                 MADE IN U.S.A.                                                                                                                                                         TST                                                                                              1
                                 P/N 22015_B                                                                                                                                   SWITCHBANK A                    EXT RLY             AUX F        SEN A             SEN B       VAC        J11

                                                                                                                                                              DIP Switch A10 must be ON.
                                                                                                                                                            For 1 x 32 Amp Service:
                                                                                                                                                              Set DIP Switch A10 such that total system amperage
                                                                                                                                                              draw never exceeds rated service input.
                                                                                                                                                          Systems using multiple DIP switches for heat disable:
                                                                                                                                                            Refer to system Hot Sheet DIP Switch Definition page
                                                                                                                                                            and set the switches shown in Table 1 such that total
                                                                                                                                                            system amperage draw never exceeds rated service input.

                                                                                        AV                                                                                                                                                       F7                                                                F1   J13
                                                                     J50                                         J29             J23                        K6            K1                                                                   F10A 250V
                                                                                                                 OZONE           PUMP 1         K9
                           J52            J51 F6, T30A 480V
                                          J                                                                                                                                                                                                                                   F3A 250V
                                                                             G     N
                                                                                                                                                                                                              J46

                                                                                                                                                          Dual Service, TN and TT Electrical Systems
                                                                      J47




                                                                                             CIRC. PUMP
                                                                                                                                                                                                                   K8
                                                                                                                                                                                                                                                              K5          J20
                                                                                                                                                                                        N




                                                   J25
                                                     5                       G     N                                                                                                                                                                    C9
                                                                                                                                                          (2 x 16 Amp)
                                                                                                                   N




                                                                                                                                  N




                                                                                                                                                                                                                                                                                               G             N
                                                   J32
                                                     2
                                                                                                                                                                                        G
                                                                                                                   G




                                                                                                                                  G




                                                                                                                                                                                                                                                                                    F3
                                                               TB1

                                                     1                              F4, T0.2A 250V
                                                                                                                                                          5 Wires (2 Lines10VAC 2 Neutrals + 1 Protective Earth)
                                                                                                                                                                   J17/26   +
                                                                                                                                                                          J72
                                                                                                                                                                                     OPT. BLWR/PUMP 2
                                                                                                                                                                                           J71
                                                                                                                                                                                                                                                                                                     10VAC

                  L2                                                                                                                                 T1
                                                                                                                                                          Protective Earth wire (Green/Yellow) must be connected
                                                                                                                         J58
                                                                                                                                                          to system ground terminal as marked.
                                                                                                                                                                                                                                                        J2A J1A




                  N2                                 2                                                                                                                                                        J1
                                                                                                                    W2
                                                                                        J28
                                                                                          8                                                               The heater runs on service line L1, while all other
                                                                                                                                                                           J2
OPTIONAL




                  L1                                 3
                                                                                                                                                          equipment, such as pumps and blowers, run on
                                                                                               J26
                                                                                                 6




                                                                                                                                           K3




                                                                                                                                                          service line L2.
                  N1                                                                                                                                                                                                                                                                                                          J18
                                                                                                                                                                                                                                                                                                                                    1

                                                     4                                                                                                                                                  J43   J10
                                                                                                                                           K4




                                              J57                                                                                                         Completely remove the white wire from J26 and J32.
                                                                                                                                                             F2
                                                                                                                                                                                                                                                                                    U4



                                 Balboa
                                                                                                                                                                                                                                                                                                         J19



                                 BALBOA INSTRUMENTS, INC.
                                                               W1
                                                                     HTR2        J101                     HTR1     00                     K2
                                                                                                                                                J90        Note: J32 and J25 are electrically identical. The white
                                                                                                                                                                     S1

                                                                                                                                                                                                        J6
                                                                                                                                                                                                               J60                               J7               J8          J44
                                                                                                                                                                                                                                                                                                   J12
                                                                                                                                                             E.GND




                                                                                                                                                                                                                                                          1               1
                                 GS500Z
                                 COPYRIGHT 2007           Pb
                                                          Pb
                                                                                                                                                           wire may be attached to either terminal before removal.       1                 1                                        1
                                                                                                                                                                                                                         J22




                                 MADE IN U.S.A.                                                                                                                                                         TST                                                                                              1
                                 P/N 22015_B                                                                                                                                   SWITCHBANK A                   EXT RLY              AUX F        SEN A             SEN B       VAC        J11




                                                                                                                                                          Systems using only 1 DIP switch (A10) for heat disable:
                                                                                                                                                            DIP Switch A10 must be OFF.
                                                                                                                                                          Systems using multiple DIP switches for heat disable:
                                                                                                                                                            Refer to system Hot Sheet DIP Switch Definition page
                                                                                                                                                            and set both switches shown in Table 1 to ON positions.




                       http://www.MyPoolSpas.com                                                                               Wholesale Pool and Spa Parts
                                                                                                                                         Page 7                                                                                                                                                                    920-925-3094
                                                                                                                                                                                                                                                                                                                           55509_97_B
Electrical Service Configuration Options
                  Systems with PCB Rev B Only                  J50
                                                                                 AV
                                                                                                          J29
                                                                                                          OZONE
                                                                                                                          J23
                                                                                                                          PUMP 1         K9
                                                                                                                                                      K6            K1
                                                                                                                                                                                                                                      F7
                                                                                                                                                                                                                                    F10A 250V
                                                                                                                                                                                                                                                                                                      F1   J13


                     J52            J51 F6, T30A 480V
                                    J                                                                                                                                                                                                                              F3A 250V
                                                                      G     N
                                                                                                                                                                                                        J46




                                                                J47
                                                                                                                                                   3-Phase Service, TN and TT Electrical Systems
                                                                                      CIRC. PUMP
                                                                                                                                                                                                           K8
                                                                                                                                                                                                                                                   K5          J20




                                                                                                                                                                                  N
                                             J25
                                               5                      G     N                                                                                                                                                                C9




                                                                                                            N




                                                                                                                           N
                                                                                                                                                                                                                                                                                    G             N
                                             J32
                                               2                                                                                                   5 Wires (3 Lines + 1 Neutral + 1 Protective Earth)




                                                                                                                                                                                  G
                                                                                                            G




                                                                                                                           G
                                                                                                                                                                                                                                                                         F3
                                                         TB1                                                                                                                                            10VAC




                                                                                                                                                                                                                                                                                          10VAC
                                                                                                                                                                               J17/26                   J72
                                               1                             F4, T0.2A 250V                                                         Protective Earth wire (Green/Yellow) must be connected
                                                                                                                                                                               OPT. BLWR/PUMP 2
                                                                                                                                                                                     J71
           L3                                                                                                                                 T1
                                                                                                                  J58                               to system ground terminal as marked.




                                                                                                                                                                                                                                             J2A J1A
           L2                                  2                                                                                                    IMPORTANT - Service MUST include a neutral wire,
                                                                                                                                                                      J1
                                                                                                             W2
                                                                                 J28
                                                                                   8                                                                with a line to neutral voltage of 230VAC.
                                                                                                                                                                       J2
           L1                                  3
                                                                                                                                                    The heater runs on service line L1.
OPTIONAL




                                                                                        J26
                                                                                          6




                                                                                                                                    K3
                                                                                                                                                    All main-board equipment run on service line L3.
           N                                                                                                                                        Addtional equipment, such as expansion boards,                                                                                                               J18
                                                                                                                                                                                                                                                                                                                       1

                                               4                                                                                                                                                  J43   J10




                                                                                                                                    K4
                                        J57                                                                                                            run on service line L2.
                                                                                                                                                       F2
                                                                                                                                                                                                                                                                         U4



                           Balboa
                                                                                                                                                                                                                                                                                              J19



                           BALBOA INSTRUMENTS, INC.
                                                         W1
                                                               HTR2       J101                     HTR1     00                     K2
                                                                                                                                         J90       Completely remove the white wire from J26 and J32,or J25.
                                                                                                                                                               S1

                                                                                                                                                                                                  J6
                                                                                                                                                                                                         J60                          J7               J8          J44
                                                                                                                                                                                                                                                                                        J12




                                                                                                                                                       E.GND
                           GS500Z                                                                                                                                                                                 1             1              1               1         1
                           COPYRIGHT 2007           Pb
                                                    Pb
                                                                                                                                                   Completely remove the blue wire from J28 and J58.




                                                                                                                                                                                                                  J22
                           MADE IN U.S.A.                                                                                                                                                         TST                                                                                         1
                           P/N 22015_B                                                                                                                                   SWITCHBANK A                   EXT RLY         AUX F        SEN A             SEN B       VAC        J11



                                                                                                                                                    If an expansion board is installed, black wire must connect
                                                                                                                                                    to J28 (Line L2) only.
                                                                                                   To an optional
                                                                                                                                                   Systems using only 1 DIP switch (A10) for heat disable:
                                                                                                   fuse-protected
                                                                                                                                                       DIP Switch A10 must be OFF.
                                                                                                   expansion board.
                                                                                                                                                   Systems using multiple DIP switches for heat disable:
                                                                                                                                                       Refer to system Hot Sheet DIP Switch Definition page
                                                                                                                                                       and set both switches shown in Table 1 to ON positions.

            NOTE:
             Not all GS5xxZ systems can support 3-Phase.
             3-Phase requires System PCB Rev B.
             If using an expansion board, the board must have fuse-protection.




                 http://www.MyPoolSpas.com                                                                              Wholesale Pool and Spa Parts
                                                                                                                                  Page 8                                                                                                                                                               920-925-3094
                                                                                                                                                                                                                                                                                                               55509_97_B
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20

More Related Content

What's hot

What's hot (20)

54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
54650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-3054650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-30
 
54515 01 gs5_gs501_sz_rca-30
54515 01 gs5_gs501_sz_rca-3054515 01 gs5_gs501_sz_rca-30
54515 01 gs5_gs501_sz_rca-30
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
54648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-3054648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
55401 01 gs5_gs510_sz_rca-30
55401 01 gs5_gs510_sz_rca-3055401 01 gs5_gs510_sz_rca-30
55401 01 gs5_gs510_sz_rca-30
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
55461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-3055461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-30
 
55403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-3055403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-30
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
55896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_3055896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_30
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 

Viewers also liked (16)

50hz eng m7
50hz eng m750hz eng m7
50hz eng m7
 
85 0100 a-1-rev 1_univ air_operation_generic
85 0100 a-1-rev 1_univ air_operation_generic85 0100 a-1-rev 1_univ air_operation_generic
85 0100 a-1-rev 1_univ air_operation_generic
 
El2001 hotsheet5
El2001 hotsheet5El2001 hotsheet5
El2001 hotsheet5
 
Dm924 a
Dm924 aDm924 a
Dm924 a
 
40122 1
40122 140122 1
40122 1
 
55663 vsp vs520_dz_bcaj
55663 vsp vs520_dz_bcaj55663 vsp vs520_dz_bcaj
55663 vsp vs520_dz_bcaj
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web
 
Crl electronics owners manual
Crl electronics owners manualCrl electronics owners manual
Crl electronics owners manual
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah
 
Herucles documents
Herucles documentsHerucles documents
Herucles documents
 
53615 mach2 gl8_gl8000_rca_30kw_3_phase_power
53615 mach2 gl8_gl8000_rca_30kw_3_phase_power53615 mach2 gl8_gl8000_rca_30kw_3_phase_power
53615 mach2 gl8_gl8000_rca_30kw_3_phase_power
 
85 0067-b5 outdoor-installation insert_web
85 0067-b5 outdoor-installation insert_web85 0067-b5 outdoor-installation insert_web
85 0067-b5 outdoor-installation insert_web
 
54671 ss el2_kgas_g
54671 ss el2_kgas_g54671 ss el2_kgas_g
54671 ss el2_kgas_g
 
54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah
 

Similar to 55509 gs5 gs501_z_rca_20 (10)

54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
55399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_3055399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_30
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah
 
55415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-3055415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-30
 
55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k
 
55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 
85 0136 spaside cutout template
85 0136 spaside cutout template85 0136 spaside cutout template
85 0136 spaside cutout template
 

55509 gs5 gs501_z_rca_20

  • 1. GS501Z Tech Sheet Balboa Instruments System PN 55509 System Model # GS5-GS501Z-RCA-2.0 Software Version # 43 EPN # 2911 Base PCBA - PN 55514 PCB GS500Z - PN 22015 Rev B Base Panels VL401 (LCD Lite Duplex) – PN 54094 VL402 (LCD Duplex Digital) – PN 54093 Optional Panels VL200 (Mini bath) – PN 52144 VL240 (MVP240) – PN 53643 VL260 (MVP260) – PN 53645 Template used: 40599_M.pdf 04/16/2008 55509_97_B.pdf 07/15/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 55509_97_B
  • 2. System Revision History System PN EPN Date Requested By Changes Made 54511 2911 07.15.2008 Balboa New system based on 54511-01, with 2kW heater 54511 2911 07.21.2008 Balboa Corrected Base PCBA - PN http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 55509_97_B
  • 3. Basic System Features and Functions Power Requirements Requires PCB Rev B. System Outputs Setup 1 (As Manufactured) (Stereo) Optional Devices Additional Options J71 and Spa-only Dolphin Remote J2A J1A J1 J2 1 J18 J10 U4 J19 J12 J60 J7 J8 J44 1 1 1 1 1 J22 1 EXT RLY AUX F SEN A SEN B VAC J11 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 55509_97_B
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 F5, F3A 250V J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 TST RST BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J6 J43 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. T AUX. F VAC MADE IN U.S.A V SWITCHBANK A RLY L SEN. A SEN. B COPYRIGHT 2005 HEATER A SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 55509_97_B
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) HIPot Testing Note: Disconnect slip terminal with green wires from J90 prior to performing HiPot test. Failure to disconnect may (Stereo) cause a false failure of the test. (optional) Reconnect terminal to J90 after successful completion of HiPot test. AV F7 F1 J13 J50 J29 J23 K6 K1 F10A 250V OZONE PUMP 1 K9 F3A 250V J52 J F6, T30A 480V J51 Audio Visual G N Blower J46 2-Spd P1 1-Spd P1 Ozone J47 CIRC. PUMP K8 K5 J20 Circ Pump N J25 5 G N C9 Spa N N G N J32 2 Light G G G F3 TB1 10VAC 10VAC J17/26 J72 1 F4, T0.2A 250V OPT. BLWR/PUMP 2 J71 T1 J58 J2A J1A 2 J1 W2 J28 8 J2 3 J26 6 K3 1 J18 4 J43 J10 K4 U4 J57 F2 Balboa J19 HTR2 J101 HTR1 00 K2 S1 W1 J90 J12 BALBOA INSTRUMENTS, INC. J60 J7 J8 J44 J6 GS50xZ mode E.GND GS500Z 1 1 1 1 1 COPYRIGHT 2007 Pb Pb J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 Heater rated @ 240V 2.0kW J11 must not be Jumpered 2.0 kW WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) GS501Z SSID # Software Wiring Color Key J11 J12 3 Neutral (Common) AC Connections 100 2.0kW Special AC Connections 63 Heater 2 Line AC Connections 43 10 Volt Connections A1, Test Mode OFF A6, 50 Hz 1 Relay Control Wires A2, Mode changes allowed A7, J17/26, P1, TE, LT J43 A8, Degrees C Memory Board Connector Key A9, Non-Circ Mode Reset A5, 2-speed P1 A10, High Amp mode Low Amp mode 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=J17/26 3=Temp 1 4 2=Pump 1 4=Light 1 2 3 4 3 Ground 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 55509_97_B
  • 6. DIP Switches and Jumpers Definitions SSID 100 63 43 Base Model GS501Z DIP Switch Key A1 Test Mode (normally OFF) Alert: A2 “ON” position: Standard mode only Blower or 1-speed Pump 2 is “OFF” position: Std/Ecn/Sleep mode changes allowed required, connect to J17/26. A3 “ON” position: use Mini Panel * For no Blower and no Pump 2, “OFF” position: use Digital Duplex or Light Duplex panel use GS500Z or GS515Z. A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: A5 A9 Circ Mode Pump 1 Speed OFF OFF Non-circ 2-speed ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed OFF ON 24 hours with 3°F shut-off 1-speed ON ON 24 hours with 3°F shut-off 2-speed A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up with J17/26 on 1-button Aux panel ** “OFF” position: Button layout will be: J17/26, Pump 1, Temp, Light A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit A10 “ON” position: heater is disabled while any high-speed pump or blower is running (low amperage mode) “OFF” position: heater can run while any/all high-speed pumps or blowers are running (high amperage mode) * Panels with button layout are not compatible when either A3 or A7 is ON. ** J2 panel connector on Main Board must be a 6-pin connector. IR Receiver is not compatible. Jumper Key J11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2. If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only. J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software. Jumper must be on Pins 2 and 3 for GS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions 1 A3: OFF 1 2 3 4 3 A 4 2 A3:ON 1 2 3 4 A Panel Button Assignments 1=J17/26 3=Temp A7: OFF 2=Pump 1 4=Light A7:ON 1=Pump 1 3=Temp Down Aux=J17/26 2=Light 4=Temp Up http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 55509_97_B
  • 7. Electrical Service Configuration Options Systems with PCB Rev B Only J50 AV J29 OZONE J23 PUMP 1 K9 K6 K1 F7 F10A 250V F1 J13 J52 J51 F6, T30A 480V J F3A 250V G N J46 Single Service, TN and TT Electrical Systems J47 CIRC. PUMP K8 K5 J20 N J25 5 G N C9 N N J32 2 (1 x 16 Amp or 1 x 32 Amp) G N G G G F3 TB1 10VAC 3 Wires (1 Line + 1 Neutral + 1J71Protective Earth) 10VAC J17/26 J72 1 F4, T0.2A 250V OPT. BLWR/PUMP 2 T1 J58 Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. J2A J1A AS MANUFACTURED 2 J1 W2 J28 8 This option is configured and shipped as the default. J2 L1 3 J26 6 K3 All equipment (pumps, blower, and heater) runs on N1 service line L1. J18 1 4 J43 J10 K4 U4 J57 F2 Balboa J19 BALBOA INSTRUMENTS, INC. W1 HTR2 J101 HTR1 00 K2 J90 Systems using only 1 DIP switch (A10) for heat disable: S1 J6 J60 J7 J8 J44 J12 E.GND 1 1 GS500Z COPYRIGHT 2007 Pb Pb For 1 x 16 Amp Service: 1 1 1 J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 DIP Switch A10 must be ON. For 1 x 32 Amp Service: Set DIP Switch A10 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table 1 such that total system amperage draw never exceeds rated service input. AV F7 F1 J13 J50 J29 J23 K6 K1 F10A 250V OZONE PUMP 1 K9 J52 J51 F6, T30A 480V J F3A 250V G N J46 Dual Service, TN and TT Electrical Systems J47 CIRC. PUMP K8 K5 J20 N J25 5 G N C9 (2 x 16 Amp) N N G N J32 2 G G G F3 TB1 1 F4, T0.2A 250V 5 Wires (2 Lines10VAC 2 Neutrals + 1 Protective Earth) J17/26 + J72 OPT. BLWR/PUMP 2 J71 10VAC L2 T1 Protective Earth wire (Green/Yellow) must be connected J58 to system ground terminal as marked. J2A J1A N2 2 J1 W2 J28 8 The heater runs on service line L1, while all other J2 OPTIONAL L1 3 equipment, such as pumps and blowers, run on J26 6 K3 service line L2. N1 J18 1 4 J43 J10 K4 J57 Completely remove the white wire from J26 and J32. F2 U4 Balboa J19 BALBOA INSTRUMENTS, INC. W1 HTR2 J101 HTR1 00 K2 J90 Note: J32 and J25 are electrically identical. The white S1 J6 J60 J7 J8 J44 J12 E.GND 1 1 GS500Z COPYRIGHT 2007 Pb Pb wire may be attached to either terminal before removal. 1 1 1 J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 Systems using only 1 DIP switch (A10) for heat disable: DIP Switch A10 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 55509_97_B
  • 8. Electrical Service Configuration Options Systems with PCB Rev B Only J50 AV J29 OZONE J23 PUMP 1 K9 K6 K1 F7 F10A 250V F1 J13 J52 J51 F6, T30A 480V J F3A 250V G N J46 J47 3-Phase Service, TN and TT Electrical Systems CIRC. PUMP K8 K5 J20 N J25 5 G N C9 N N G N J32 2 5 Wires (3 Lines + 1 Neutral + 1 Protective Earth) G G G F3 TB1 10VAC 10VAC J17/26 J72 1 F4, T0.2A 250V Protective Earth wire (Green/Yellow) must be connected OPT. BLWR/PUMP 2 J71 L3 T1 J58 to system ground terminal as marked. J2A J1A L2 2 IMPORTANT - Service MUST include a neutral wire, J1 W2 J28 8 with a line to neutral voltage of 230VAC. J2 L1 3 The heater runs on service line L1. OPTIONAL J26 6 K3 All main-board equipment run on service line L3. N Addtional equipment, such as expansion boards, J18 1 4 J43 J10 K4 J57 run on service line L2. F2 U4 Balboa J19 BALBOA INSTRUMENTS, INC. W1 HTR2 J101 HTR1 00 K2 J90 Completely remove the white wire from J26 and J32,or J25. S1 J6 J60 J7 J8 J44 J12 E.GND GS500Z 1 1 1 1 1 COPYRIGHT 2007 Pb Pb Completely remove the blue wire from J28 and J58. J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 If an expansion board is installed, black wire must connect to J28 (Line L2) only. To an optional Systems using only 1 DIP switch (A10) for heat disable: fuse-protected DIP Switch A10 must be OFF. expansion board. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions. NOTE: Not all GS5xxZ systems can support 3-Phase. 3-Phase requires System PCB Rev B. If using an expansion board, the board must have fuse-protection. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 55509_97_B