SlideShare a Scribd company logo
1 of 8
Download to read offline
VS503SZ Tech Sheet

 Balboa Instruments
 System PN 54635-01

 System Model # VSP-VS503SZ-DCAH
 Software Version # 43
 EPN # 2808


 Base PCBA - PN 54363-01
 PCB VS500Z - PN 22972 Rev C or D

 Base Panels
 VL701S (Serial Standard) – PN 52298-01




 Template used: 40600_R.pdf 04/16/2008
 54365-01_A.pdf 08/26/2008



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                                 54635-01_A
System Revision History
System PN EPN           Date      Requested By                             Changes Made
54635-01     2808 08.26.2008 Balboa              Software update to version 43.




      http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                      Page 2                              920-925-3094
                                                                                                   54635-01_A
Basic System Features and Functions

 Power Requirements



 System Outputs
 Setup 1 (As Manufactured)



              (Stereo)


 Optional Devices




                                                                                                                             FUSE
 Additional Options                             K8                                   W2
                                                                                                          K5
                                                                              W3
                                                                     J1 J1A
                                                                                                                      J10



                                                                            J2A
                                                                                                                            J18




                                                                                                          2 3
                                                                                                     1
                                                                                                U4       J12

                                                     J2



                                                                                                                            J13
                                                                                         BALBOA INSTRUMENTS, INC. 2-SPD
                                                  J60      J22                       J44 VS500Z                   EXT RLY
                                                                    J7       J8
                                                                                         P/N 22972 REV D


                                                 EXT.     AUX. F                     VAC MADE IN U.S.A
                                                 RLY               SEN. A   SEN. B        COPYRIGHT 2005




http://www.MyPoolSpas.com    Wholesale Pool and Spa Parts
                                       Page 3                                                                   920-925-3094
                                                                                                                         54635-01_A
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                       Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                                 three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                                        a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                                         configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                                  “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                         “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                        “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                  TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                          J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                   PUMP                  OZONE
                               K1                                                                                                                                                                                                                      J23                 J29
                                                                                                                                                                F1                                                                                                                                                                        F5, F3A 250V                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                   G




                                                                                                                                                                                                                                                                      G




                                                                                                                                                                                                                                                                                           K5
                                                                                                                                                                                              J90




                                                                                                                                                                                                                                                                                                                                                                       G     C
                                                                                                                                                                                                                                                   C




                                                                                                                                                                                                                                                                      C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                              J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                                               J12
                              W1                                                        K8                                                     K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                          K4      K1
                                                                                                                                                                                                                                                   SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                                                J18
                                                                                                                                                                                                                                                         F2                                                                                                           U4
                                                                                                                                                                                                                                                                                                                                               J13




                                                                                                                    J2A                                                                                       T0.25A 250V
                                                                                                                                                                                                                                                   NEUTRAL
                                                                                                                                                                                                                                                                      WHT AC                                                                                                     J1
                                                                                                                                                                     J18




                                                                                                                                                                                                    W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                               K3
                                                                                                                                         U4   J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                           VS100
                                                                                                                                                                                                                      P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                            J26                                                                                                 F4
                                                                                                                                                                                                                  Balboa




                                                                             J43
                                                                                                                                                                                                                                 © 2006




                         F2                                                                                                                                                                 LINE
                                                                                                                                                                                                                                                                                      K2




                                                                                                                                                                     J13                                                                                                                                            TST             RST
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                     S1                    J6 J43
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                                       J7          J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                 J9




                                                                            S1 TST       EXT.
                                                                                           T      AUX. F                      VAC MADE IN U.S.A
                                                                                                                              V
                                                           SWITCHBANK A                  RLY
                                                                                          L                SEN. A   SEN. B         COPYRIGHT 2005                                                                                                            HEATER
                                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                                                                            SWITCHBANK A                      SEN. A     SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                                                  Page 4                                                                                                                                                             920-925-3094
                                                                                                                                                                                                                                                                                                                                              54635-01_A
Wiring Configuration and DIP Settings
                Setup 1 (As Manufactured)
                                                                                                                      (Stereo)




                                                                                                                             PCBA rev D only.
                                                                                                                             Black jumper required.                                              Ozone and Circ Pump must be same voltage.
                                                                                                                             Do not remove.                                                      DIP switch A9 must be ON if Circ Pump is installed.
                                                                                                                        K1                                                               F7 FUSE 20A 250V                                    J47




                                                                                                                                                                                                                                    J46
                                                                                                                                                                            W10                                                                               J29
      CLASS G FUSE 30A                                  BLK AC                                K6 J23                                                    J50
                                             F5           J61    J62                                             J74




                                                                                                                                                                                                                                          Circ.Pump
                                                                                                                                                                                                                                                                                       F1




                                                                                                                                                      Audio Visual
                                                                                                 2-Spd P1                                                                                                                                                                       J20




                                                                                                                                                                                        J17/26




                                                                                                                                                                                                                                                             Ozone



                                                                                                                                                                                                                                                                                             FUSE 3A 250V
                                  WHT AC
                                    T




                                                                                                                                                                                                                                                                                 C
                                                                                                                  J73




                                                                                                                                                                                                                                                                               Light
                                                                                                                                                                                                                                               C




                                                                                                                                                                                                                                                                               12V
                                                                                                                                                                                                                                                                     C
                                                                                                     C




                                                                                                                                                                                   C
                                                                                                                                                             C




                                                                                                                                                                                                                                               G




                                                                                                                                                                                                                                                                                 G
                                                                                                                                                                                                                                                                     G
                                                                                                                                                                                            W7




                                                                                                                                        W4
                                                                                                     G




                                                                                                                                                                                   G
                                                                                                                                                             G
                    J11    J15    J16 J25 J63 J64
      J66 J65
                                                                                                                 W1                                                                                   K8                                                              K5
                                                                                                                                                                                                                                               W2
                                                                                                                                         T1                                                 K9                                       W3
                                 NEUTRAL




                                                                                  F4 FUSE .3A 250V
                                                                                                                                                                                                                            J1 J1A
                                  WHITE




                                                                                                                                                                                                                                                                                       J10
                                 BLACK
                                  HOT




                                                                                                                                                                                                                                   J2A
                                                                                                                                                                                                                                                            VS5xxS mode




                                                                                                                                                                                                                                                                                             J18
          TORQUE
          RANGE
                                 RED
                                 HOT




                                                                                                                                                                                                                                                                         2 3
          FOR TB1:                                                                                          K3                                                                                                                                                   1
K4        27-30 IN. LBS.                                                                                                                                                                                                                                    U4       J12
                                                                                                            K2
                                                                TB1                                                                                                                                        J2
                            J32 J33 J34          J35                                                                                                                                       J43

                            J36            J37                                                              F2
                                  RED AC                                                                                                                                                                                                                                                    J13
                                                                                                                                                                                                                                                      BALBOA INSTRUMENTS, INC. 2-SPD
                                                                                                                                                                                                       J60       J22                              J44 VS500Z                   EXT RLY
                                                                                                                                                                                                                           J7        J8

            Balboa                                 HTR2                HTR1                                                                                                                      J6
                                                                                                                                              E.GND




                                                                                                                                                                                                                                                      P/N 22972 REV D


                   J100                                   J101                                                                                                                            S1 TST       EXT.     AUX. F                            VAC MADE IN U.S.A
                                                                                                                                                                         SWITCHBANK A                  RLY                SEN. A   SEN. B             COPYRIGHT 2005


                                                                                      Heater rated @ 240V
                                                       5.5 kW                         (Approx. 1.25kW @ 120V)




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                  VS51x/VS5xxS/VS5xxD
     SSID #                                                                                                                            Compatible
                                                                                                                                                                                                           Wiring Color Key
                                                                                                                                                                                                                                      120 Volt Connections
      100                                                                                                                         J12                                                                                                 240 Volt Connections
      93                                                                                                                                      1                      2         3                                                      Black AC Jumpers
      43                                                                                                                                                                                                                              12 Volt Connections
                          A1, Test Mode OFF
                                                                                                                                                                                                                                      Relay Control Wires
                          A2, See Table 1          A7, Exp Board Equip Disabled
                          A3, J17/26 Pump Disabled                                                                                       J43                                                               Board Connector Key
                                                                                                                                                                     Memory
                                                                                  A9, Non-Circ Mode
                          A5, 2-speed P1                                                                                                                             Reset                                 1             Typically Line voltage
                                                                                  A10, See Table 1
                                                                                                                                                                                                           2             Typically Line voltage for 2-speed pumps
     Panel Button Assignments                                                                    Panel Button Positions                                                                                    3             Neutral (Common)
     1=Mode                      5=Pump 1                                                                                    2                                       7     4
                                                                              4        1           2                                                                                                       4             Ground
     2=Temp Up                   6=Unused
                                                                                                                        1    3                                       5     6
     3=Temp Down                 7=Unused                                     5   6    7           3
                                                                                                                                                                                                                         Note flat sides in connector
     4=Light

           http://www.MyPoolSpas.com                                                                Wholesale Pool and Spa Parts
                                                                                                              Page 5                                                                                                                            920-925-3094
                                                                                                                                                                                                                                                         54635-01_A
DIP Switches and Jumpers Definitions
  SSID 100 93 43                                         Base Model VS503SZ-VS504SZ-VS514SZ
DIP Switch Key
     A1 Test Mode (normally OFF)
A2+A10 Control amp draw requirements (See Table 1)                                                             Table 1         # of Hi-Speed
     A3 “ON” position: J17/26 Enabled for 1-speed Pump only.                                                                   Pumps/Blower
         “OFF” position: J17/26 Disabled.                                                                                   Before Heat Disabled
     A4 Aux Freeze (must be OFF)                                                                               A2        A10
 A5+A9 Pump 1 speeds and Circ Modes:                                                                           OFF       OFF           0
            A5       A9      Circ Mode                                             Pump 1 Speed                ON        OFF           1
            OFF      OFF     Non-circ                                              2-speed                     OFF       ON            2
            ON       OFF     Circ "acts like Pump 1 low" (filters/polls/ect)       1-speed                     ON        ON            3
            OFF      ON      24 hours with 3°F shut-off                            1-speed
            ON       ON      24 hours with 3°F shut-off                            2-speed
     A6 “ON” position: 50Hz operation
           “OFF” position: 60Hz operation
     A7 “ON” position: Expander Board Enabled for Blower or 1-speed Pump.
           “OFF” position: Expander Board Disabled
     A8 “ON” position: temperature is displayed in degrees Celsius
           “OFF” position: temperature is displayed in degrees Fahrenheit
When using a Blower, use X-B expander board. When using a 1-speed Pump 3, use X-P or X-P231, depending on amperage requirements.
* Panel with button layout         is not compatible.
Jumper Key
J12     Factory set. DO NOT MOVE.
        Jumper must be on Pins 1 and 2 for VS51xZ/VS52xZ/VS5xxSZ/VS5xxDZ software.
        Jumper must be on Pins 2 and 3 for VS50xZ software.
J43     When jumper is placed on 2 pins during power-up, system will reset persistent memory.
        Leave on 1 pin only to enable persistent memory feature.

 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this tech sheet.



            Panel Button Positions                                                                      Aux Panel Information

    4       1                2                   2                             7     4            Supports 2-button aux panel

    5   6   7                3              1    3                             5     6
                                                                                              VX20         5         6         When A3 is ON


                                                                                              VX20         5         7         When A3 is OFF


            Panel Button Assignments

  1=Mode             5=Pump 1
                                                                                                  Supports 4-button aux panel
  2=Temp Up          6=Pump 2 (when A3 is ON)
  3=Temp Down        7=Exp Board (when A7 is ON)                                              VX40S        5 6            4 7
  4=Light


 http://www.MyPoolSpas.com                           Wholesale Pool and Spa Parts
                                                               Page 6                                                           920-925-3094
                                                                                                                                         54635-01_A
Ozone Connections
Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or
240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover
of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2
connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the
required voltage.

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ
pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage
is selected.

Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone
generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next
to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in place.
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.

 Balboa Ozone connector configuration for 120V 60Hz                                                B
                                           Line - Black conductor
                    Use this slot for the leftover Red conductor
      Common - Install the White conductor here for 120V ozone
                                                                                                         G
                                      Ground (Green) conductor

                                                                                        Flat sides of sockets as shown
 Balboa Ozone connector configuration for 240V 60Hz                                                B
                                           Line - Black conductor
                   Use this slot for the leftover White conductor
        Common - Install the Red conductor here for 240V ozone
                                                                                                         G
                                       Ground (Green) conductor



FUSE 20A 250V               J47
                      J46




                                     J29
                                                                          Line - Black conductor
                         Circ.Pump
                              R




                                              J20     F1                  Use this slot for the leftover conductor
                              B




                                                                          Common - Red for 240V or White for 120V ozone (See W2 wire)
                                                                          Ground (Green) conductor
                                                           FUSE 3A 250V
                                               W
                                             Light
                              W




                                             12V




                                                                          W2 wire determines voltage
                                               W
                              G




 K8                                     K5
                              W2
                       W3
                J1 J1A
                                                     J10


       http://www.MyPoolSpas.com                     Wholesale Pool and Spa Parts
                                                               Page 7                                                920-925-3094
                                                                                                                              54635-01_A
Serial Standard Panel Configurations

                 Light              Mode                     Warm




                                                              Heat
SETUP 1




                Jets 1                                        Cool




          VL701S (Serial Standard)
          PN 52298-01 with No Overlay (Example shown)
           Connects to Main Board terminal J1




             http://www.MyPoolSpas.com         Wholesale Pool and Spa Parts
                                                         Page 8               920-925-3094
                                                                                       54635-01_A

More Related Content

What's hot (17)

54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah
 
54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah
 
54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj
 
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_2055509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
 
55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah
 
54751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-3054751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-30
 
54511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-3054511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-30
 
56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah
 
54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k
 
55666 vsp vs525_bcah
55666 vsp vs525_bcah55666 vsp vs525_bcah
55666 vsp vs525_bcah
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 

Viewers also liked (13)

85 0064-a rev 5-standard operation_web
85 0064-a rev 5-standard operation_web85 0064-a rev 5-standard operation_web
85 0064-a rev 5-standard operation_web
 
Hayward controls 2100_operating
Hayward controls 2100_operatingHayward controls 2100_operating
Hayward controls 2100_operating
 
Baker hydro spa_package
Baker hydro spa_packageBaker hydro spa_package
Baker hydro spa_package
 
54603 vsp vs300_fl5_ccah
54603 vsp vs300_fl5_ccah54603 vsp vs300_fl5_ccah
54603 vsp vs300_fl5_ccah
 
53889 20 vsp_vs511s_dcah
53889 20 vsp_vs511s_dcah53889 20 vsp_vs511s_dcah
53889 20 vsp_vs511s_dcah
 
85 0076-a rev 3-eco-2 plus operation_web
85 0076-a rev 3-eco-2 plus operation_web85 0076-a rev 3-eco-2 plus operation_web
85 0076-a rev 3-eco-2 plus operation_web
 
54388 04 e1_p_el1001m3_dcah
54388 04 e1_p_el1001m3_dcah54388 04 e1_p_el1001m3_dcah
54388 04 e1_p_el1001m3_dcah
 
54648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-3054648 01 gs5_gs514_sz_rca-30
54648 01 gs5_gs514_sz_rca-30
 
54464 04 e2_p_el2001m3_ycaj
54464 04 e2_p_el2001m3_ycaj54464 04 e2_p_el2001m3_ycaj
54464 04 e2_p_el2001m3_ycaj
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 

Similar to 54635 01 vsp_vs503_sz_dcah (10)

56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
55403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-3055403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-30
 
55106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_3055106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_30
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

54635 01 vsp_vs503_sz_dcah

  • 1. VS503SZ Tech Sheet Balboa Instruments System PN 54635-01 System Model # VSP-VS503SZ-DCAH Software Version # 43 EPN # 2808 Base PCBA - PN 54363-01 PCB VS500Z - PN 22972 Rev C or D Base Panels VL701S (Serial Standard) – PN 52298-01 Template used: 40600_R.pdf 04/16/2008 54365-01_A.pdf 08/26/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 54635-01_A
  • 2. System Revision History System PN EPN Date Requested By Changes Made 54635-01 2808 08.26.2008 Balboa Software update to version 43. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 54635-01_A
  • 3. Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) (Stereo) Optional Devices FUSE Additional Options K8 W2 K5 W3 J1 J1A J10 J2A J18 2 3 1 U4 J12 J2 J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 P/N 22972 REV D EXT. AUX. F VAC MADE IN U.S.A RLY SEN. A SEN. B COPYRIGHT 2005 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 54635-01_A
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 F5, F3A 250V J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 TST RST BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J6 J43 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. T AUX. F VAC MADE IN U.S.A V SWITCHBANK A RLY L SEN. A SEN. B COPYRIGHT 2005 HEATER A SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 54635-01_A
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) (Stereo) PCBA rev D only. Black jumper required. Ozone and Circ Pump must be same voltage. Do not remove. DIP switch A9 must be ON if Circ Pump is installed. K1 F7 FUSE 20A 250V J47 J46 W10 J29 CLASS G FUSE 30A BLK AC K6 J23 J50 F5 J61 J62 J74 Circ.Pump F1 Audio Visual 2-Spd P1 J20 J17/26 Ozone FUSE 3A 250V WHT AC T C J73 Light C 12V C C C C G G G W7 W4 G G G J11 J15 J16 J25 J63 J64 J66 J65 W1 K8 K5 W2 T1 K9 W3 NEUTRAL F4 FUSE .3A 250V J1 J1A WHITE J10 BLACK HOT J2A VS5xxS mode J18 TORQUE RANGE RED HOT 2 3 FOR TB1: K3 1 K4 27-30 IN. LBS. U4 J12 K2 TB1 J2 J32 J33 J34 J35 J43 J36 J37 F2 RED AC J13 BALBOA INSTRUMENTS, INC. 2-SPD J60 J22 J44 VS500Z EXT RLY J7 J8 Balboa HTR2 HTR1 J6 E.GND P/N 22972 REV D J100 J101 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 Heater rated @ 240V 5.5 kW (Approx. 1.25kW @ 120V) WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) VS51x/VS5xxS/VS5xxD SSID # Compatible Wiring Color Key 120 Volt Connections 100 J12 240 Volt Connections 93 1 2 3 Black AC Jumpers 43 12 Volt Connections A1, Test Mode OFF Relay Control Wires A2, See Table 1 A7, Exp Board Equip Disabled A3, J17/26 Pump Disabled J43 Board Connector Key Memory A9, Non-Circ Mode A5, 2-speed P1 Reset 1 Typically Line voltage A10, See Table 1 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Mode 5=Pump 1 2 7 4 4 1 2 4 Ground 2=Temp Up 6=Unused 1 3 5 6 3=Temp Down 7=Unused 5 6 7 3 Note flat sides in connector 4=Light http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 54635-01_A
  • 6. DIP Switches and Jumpers Definitions SSID 100 93 43 Base Model VS503SZ-VS504SZ-VS514SZ DIP Switch Key A1 Test Mode (normally OFF) A2+A10 Control amp draw requirements (See Table 1) Table 1 # of Hi-Speed A3 “ON” position: J17/26 Enabled for 1-speed Pump only. Pumps/Blower “OFF” position: J17/26 Disabled. Before Heat Disabled A4 Aux Freeze (must be OFF) A2 A10 A5+A9 Pump 1 speeds and Circ Modes: OFF OFF 0 A5 A9 Circ Mode Pump 1 Speed ON OFF 1 OFF OFF Non-circ 2-speed OFF ON 2 ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed ON ON 3 OFF ON 24 hours with 3°F shut-off 1-speed ON ON 24 hours with 3°F shut-off 2-speed A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: Expander Board Enabled for Blower or 1-speed Pump. “OFF” position: Expander Board Disabled A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit When using a Blower, use X-B expander board. When using a 1-speed Pump 3, use X-P or X-P231, depending on amperage requirements. * Panel with button layout is not compatible. Jumper Key J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS52xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions Aux Panel Information 4 1 2 2 7 4 Supports 2-button aux panel 5 6 7 3 1 3 5 6 VX20 5 6 When A3 is ON VX20 5 7 When A3 is OFF Panel Button Assignments 1=Mode 5=Pump 1 Supports 4-button aux panel 2=Temp Up 6=Pump 2 (when A3 is ON) 3=Temp Down 7=Exp Board (when A7 is ON) VX40S 5 6 4 7 4=Light http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 54635-01_A
  • 7. Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone G Ground (Green) conductor Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone G Ground (Green) conductor FUSE 20A 250V J47 J46 J29 Line - Black conductor Circ.Pump R J20 F1 Use this slot for the leftover conductor B Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor FUSE 3A 250V W Light W 12V W2 wire determines voltage W G K8 K5 W2 W3 J1 J1A J10 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 54635-01_A
  • 8. Serial Standard Panel Configurations Light Mode Warm Heat SETUP 1 Jets 1 Cool VL701S (Serial Standard) PN 52298-01 with No Overlay (Example shown) Connects to Main Board terminal J1 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 54635-01_A