SlideShare a Scribd company logo
1 of 7
Download to read offline
GS100 Tech Sheet

 Balboa Water Group
 System PN 54676

 System Model # MM7-GS100-DCA-1.0K
 Software Version # 41
 EPN # 3449


 Base PCBA - PN 54677
 PCB VS100 - PN 22964 Rev B

 Base Panels
 VL200 (Mini) – PN 55123
 VL240 (MVP240) – PN 55080
 VL260 (MVP260) – PN 55081
 VL401 (LCD Lite Duplex) – PN 54665
 VL403 (LED Lite Duplex) – PN 54664




 Template used: 40749_A.pdf 02/26/2007
 54676_97_A.pdf 08/16/2010



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                                54676_97_A
Basic System Features and Functions

 Power Requirements
 • 230VAC, 1~, 16A, 50Hz
 • 3 wires (line, neutral, ground)

 System Outputs
 Setup 1 (As Manufactured)
 • 230V Pump 1, 2-Speed
 • 230V Ozone
 • 10V Spa Light
 • 230V 1.0kW Heater




 Additional Options
                                                                                                              F5, F3A 250V                     J20
 • MoodEFX Lighting                                              K5
                                                                                                                                           G     C
   Connects to Spa Light terminal J20
 • FiberEFX Lighting
                                                                                                                   J12




   Connects to Spa Light terminal J20

                                                                                                                                    J18

                                                                                                                                          U4
                                                                                                                   J13




                                                                                                                                                     J1




                                                                      F4
                                                            K2




                                                                                        TST             RST
                                                                           S1                  J6 J43
                                                                                                                   J7          J8
                                                       J9




                                                                                SWITCHBANK A                      SEN. A     SEN. B




http://www.MyPoolSpas.com            Wholesale Pool and Spa Parts
                                               Page 2                                                                               920-925-3094
                                                                                                                                            54676_97_A
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                    • Three numbers in a row, which are the SSID (the System Softwar
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if
• Power down by disconnecting power source from spa.                                                                                                                                    three numbers are                    , that is a VS511SZ at version
• Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              • Displayed next is: “ ” (indicating the system is configured for
• Power up by connecting power source to spa.                                                                                                                                           a heater between 3 and 6 kW) or “ ” (indicating the system is
• Wait until “ ” is displayed on your panel.                                                                                                                                            configured for a heater effectively* between 1 and 3 kW).
• Power down again.                                                                                                                                                                     “ ” should appear for all VS models running at 240VAC.
• Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                            “ ” should appear for all VS models running at 120VAC, as wel
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC w
• Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                     • “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Refere
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information abou
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                   TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                           J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                    PUMP                  OZONE
                               K1                                                                                                                                                                                                                       J23                 J29
                                                                                                                                                                F1                                                                                                                                                                                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                    G




                                                                                                                                                                                                                                                                       G



                                                                                                                                                                                                                                                                                            K5
                                                                                                                                                                                               J90




                                                                                                                                                                                                                                                                                                                                                   G     C
                                                                                                                                                                                                                                                    C




                                                                                                                                                                                                                                                                       C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                               J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                             J12
                              W1                                                        K8                                                    K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                           K4      K1
                                                                                                                                                                                                                                                    SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                            J18
                                                                                                                                                                                                                                                          F2                                                                                      U4




                                                                                                                                                                                                                                                                                                                             J13
                                                                                                                    J2A                                                                                        T0.25A 250V
                                                                                                                                                                                                                                                    NEUTRAL
                                                                                                                                                                                                                                                                       WHT AC
                                                                                                                                                                     J18




                                                                                                                                                                                                     W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                                K3
                                                                                                                                        U4    J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                            VS100
                                                                                                                                                                                                                       P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                             J26                                                                                                 F4
                                                                                                                                                                                                                   Balboa




                                                                             J43
                                                                                                                                                                                                                                  © 2006




                         F2                                                                                                                                                                  LINE
                                                                                                                                                                                                                                                                                       K2




                                                                                                                                                                     J13
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                      S1
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                     J7        J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                  J9




                                                                            S1 TST       EXT.     AUX. F                      VAC MADE IN U.S.A
                                                           SWITCHBANK A                  RLY               SEN. A   SEN. B        COPYRIGHT 2005                                                                                                              HEATER
                                                                                                                                                                                                                                                                                                             SWITCHBANK A   SEN. A   SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




http://www.MyPoolSpas.com                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                     Page 3                                                                                                                                                                 920-925-3094
                                                                                                                                                                                                                                                                                                                    54676_97_A
Wiring Configuration and DIP Settings
           Setup 1 (As Manufactured)                                                                                                                                                         HIPot Testing Note:
                                                                                                                                                                                             Disconnect slip terminal with green
• 230V Pump 1, 2-Speed                                                                                          • 230V 1.0kW Heater                                                          wires from J90 prior to performing
                                                                                                                                                                                             HiPot test. Failure to disconnect will
• 10V Spa Light                                                                                                 • VL401 Main Panel                                                           cause a false failure of the test.
• 230V Ozone                                                                                                                                                                                 Reconnect terminal to J90 after
                                                                                                                                                                                             successful completion of HiPot test.

                                                                                                                    Ozone runs with Pump 1 low-speed.
                                                                                    PUMP                        OZONE
                                                                                                  J23                    J29
                                                                                                                                                                                           F5, F3A 250V                       J20
                                                                                            2-Spd P1
                                                                                            G




                                                                                                                    G
                                                                                                                                          K5
                                                                                                                                                                                                                            10V
                                                                                                                    Ozone
                                                                                                                                                                                                                            G    C
                                                                                                                                                                                                                            Light
              J90




                                                                                               C




                                                                                                                     C
              J50




                                                                                                                                                                                                 J12
                                           K4             K1
                               V
                   F1, T20A 480V




                                                                                                                                                                                                                     J18
                                                                                                           F2                                                                                                              U4




                                                                                                                                                                                                 J13
                                                T0.25A 250V
                                                                                              NEUTRAL
                                                                                                                                                                                                                                       J1
                                           W1                                          J58             J57
                                                                                                                        K3
                                                                                    VS100
                                                               P/N 22964_B MADE IN U.S.A.




            J26                                                                                                                                F4
                                                           Balboa
                                                                          © 2006




            LINE
                                                                                                                                     K2




              TB1                                                                                                                                                    TST             RST
                                                                                                                                                    S1                      J6 J43
                                                NEUTRAL




                                                                                                                                                                                                 J7             J8
                                                                                                                                J9




                                                                                                  1.0 kW
                                   LINE




                                                                                                           HEATER                                                                               SEN. A       SEN. B
                                                                                                                                                             SWITCHBANK A



 WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
 WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)


   SSID #                                                                                                                                                                                   Wiring Color Key
                                                                                                                                                                                                                 Neutral (Common) AC Connections
     100                                                                                                                                                                                                         Special AC Connections
     59                                                                                                                                                                                                          Line AC Connections
     41                                                                                                                                                                                                          10 Volt Connections
                            A1, Test Mode OFF            A6, 50 Hz                                                                                             J43
                                                                                                                                                                                                                 Relay Control Wires
                            A2, Un, LT, TD, TU
                                P1, P1, TE, LT           A7, Mode changes allowed                                                                                    Memory
                                                         A8, Degrees C                                                                                               Reset                   Board Connector Key
                            A4, N/A (must be OFF)        A9, P1-low timeout, Table 1
                                                                                                                                                                                            1
                            A5, P1-high timeout, Table 1 A10, High Amp mode
                                                              Low Amp mode                                                                                                                             Typically Line voltage
                                                                                                                                                                                            2          Typically Line voltage for 2-speed pumps
    Panel Button Assignments                                                                                            Panel Button Positions                                              3          Neutral (Common)
    1=Unused
    1=Pump 1                              3=Temp Down                                                                                                    1                                  4          Ground
    2=Light 1
    2=Pump                                4=Light
                                          4=Temp Up                                                    1        2                3        4                             3
                                                                                                                                                         4     2
                                                                                                                                                                                                       Note flat sides in connector


        http://www.MyPoolSpas.com                                                                                            Wholesale Pool and Spa Parts
                                                                                                                                       Page 4                                                                              920-925-3094
                                                                                                                                                                                                                                   54676_97_A
DIP Switches and Jumpers Definitions
   SSID 100 59 41                                                        Base Model GS100
DIP Switch Key
     A1 Test Mode (normally OFF)
     A2 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up *
          “OFF” position: Button layout will be: Unused, Pump 1, Temp, Light
     A3 “ON” position: use Mini Panel *
          “OFF” position: use Lite Duplex or Digital Duplex panel
     A4 N/A (must be OFF)
     A5 Pump 1 high-speed timeout, see Table 1                                                     Table 1     Pump 1 Timeouts
     A6 “ON” position: 50Hz operation
          “OFF” position: 60Hz operation                                                            A5     A9    Low-spd Hi-spd
     A7 “ON” position: Standard mode only
                                                                                                   OFF OFF       2 hours 15 min
          “OFF” position: Std/Ecn/Sleep mode changes allowed
                                                                                                    ON     OFF   2 hours 30 min
     A8 “ON” position: temperature is displayed in degrees Celsius
                                                                                                   OFF     ON    15 min 15 min
          “OFF” position: temperature is displayed in degrees Fahrenheit
                                                                                                    ON     ON    30 min 30 min
     A9 Pump 1 low-speed timeout, see Table 1
    A10 “ON” position: heater is disabled while the high-speed pump is running (low amperage mode)
          “OFF” position: heater can run while the high-speed pump is running (high amperage mode)
* Panels with button layout         are not compatible when A2 or A3 is ON.
Note: No blower or second pump available.




Jumper Key
J43     When jumper is placed on 2 pins during power-up, system will reset persistent memory.
        Leave on 1 pin only to enable persistent memory feature.




 WARNING:
 •Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
 •Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
 •Contact Balboa if you require additional configuration pages added to this tech sheet.

                                    Panel Button Positions
                                                                              1
                       A3: OFF     1      2                3      4                            3
                                                                              4    2


                       A3:ON                     1     2    3     4



                                 Panel Button Assignments
                                  1=Unused                 3=Temp
                       A2: OFF 2=Pump 1                    4=Light

                       A2:ON      1=Pump 1                 3=Temp Down
                                  2=Light                  4=Temp Up
 http://www.MyPoolSpas.com                     Wholesale Pool and Spa Parts
                                                         Page 5                                            920-925-3094
                                                                                                                   54676_97_A
Ozone Connections
Note: A special tool is required to remove the pins from the connector body once they are snapped in place.
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.



  Balboa Ozone connector configuration for 230VAC 50Hz:
                                                                                                  L
                                      Black or Brown Line Conductor
                                                              Empty
                                     White or Blue Neutral Conductor                                  N
                                                              Empty

                                                                                       Flat sides of sockets as shown




                       PUMP              OZONE
                               J23               J29
                                                                       Not used
                        Circ.Pump
                        G




                                                       K5
 J90




                                                                       Neutral - White or Blue conductor
                           C




                                                                       Not used
                                                                       Line - Black or Brown conductor
 J50




         K4     K1




                                    F2




       http://www.MyPoolSpas.com                        Wholesale Pool and Spa Parts
                                                                  Page 6                                            920-925-3094
                                                                                                                            54676_97_A
Duplex Panel Configurations

                                                                                              Heat
SETUP (AS MANUFACTURED)




                                              Jets     Light                                Cool     Warm                         DIP switch A3 must be OFF


                          VL403 (Lite Digital)                                                                                                     Heat

                          PN 54664 with Overlay PN 11884
                          • Connects to Main Panel terminal J1
                                                                                                            Jets   Light                          Cool     Warm



                                                                                          VL401 (Lite Digital)
                                                                                                 Lite
                                                                                          PN 54665 with Overlay PN 11885
                                                                                          • Connects to Main Panel terminal J1




                                                       Jets    Light     Cool      Warm

                                                                                                                                  DIP switch A3 must be ON
                          VL200 (Mini Panel)
                          PN 55123 with Overlay PN 11852
                          • Connects to Main Panel terminal J1
OPTIONAL PANELS




                                                                  Jets     Light     Cool   Warm




                          VL240 (MVP240)
                          PN 55080 with Overlay PN 11745
                                                                                                                           Jets    Light   Cool     Warm
                          • Connects to Main Panel terminal J1



                                                                            VL260 (MVP260)
                                                                            PN 55081 with Overlay PN 11746
                                                                            • Connects to Main Panel terminal J1
                                 http://www.MyPoolSpas.com                          Wholesale Pool and Spa Parts
                                                                                              Page 7                                                       920-925-3094
                                                                                                                                                                   54676_97_A

More Related Content

What's hot

What's hot (20)

55896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_3055896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_30
 
54517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-3054517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-30
 
55461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-3055461 01 gs5_gs504_sz_rca-30
55461 01 gs5_gs504_sz_rca-30
 
55401 01 gs5_gs510_sz_rca-30
55401 01 gs5_gs510_sz_rca-3055401 01 gs5_gs510_sz_rca-30
55401 01 gs5_gs510_sz_rca-30
 
54650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-3054650 01 gs5_gs504_sz_rca-30
54650 01 gs5_gs504_sz_rca-30
 
55403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-3055403 01 gs5_gs514_sz_rca-30
55403 01 gs5_gs514_sz_rca-30
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_2055509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
 
54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
55106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_3055106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_30
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 
54511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-3054511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-30
 
55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
54751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-3054751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-30
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah
 
54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah
 

Viewers also liked (13)

850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
Om 203
Om 203Om 203
Om 203
 
54670 ss el2_kelec_e
54670 ss el2_kelec_e54670 ss el2_kelec_e
54670 ss el2_kelec_e
 
Hs v6510 manual-rev1
Hs v6510 manual-rev1Hs v6510 manual-rev1
Hs v6510 manual-rev1
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 
54645 01 vsp_vs300_fh5_dcah
54645 01 vsp_vs300_fh5_dcah54645 01 vsp_vs300_fh5_dcah
54645 01 vsp_vs300_fh5_dcah
 
85 0076-e eco-2 plus-installation insert_web
85 0076-e eco-2 plus-installation insert_web85 0076-e eco-2 plus-installation insert_web
85 0076-e eco-2 plus-installation insert_web
 
85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web
 
85 0062-a rev 5-eco-1 operation_web
85 0062-a rev 5-eco-1 operation_web85 0062-a rev 5-eco-1 operation_web
85 0062-a rev 5-eco-1 operation_web
 
53859 0420 gl8_gl8000m3_rca-30
53859 0420 gl8_gl8000m3_rca-3053859 0420 gl8_gl8000m3_rca-30
53859 0420 gl8_gl8000m3_rca-30
 
85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web
 
52893 20 mach202_20_el1_el1000_dcah
52893 20 mach202_20_el1_el1000_dcah52893 20 mach202_20_el1_el1000_dcah
52893 20 mach202_20_el1_el1000_dcah
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 

Similar to 54676 mm7 gs100_dca_10_k (12)

54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj
 
55399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_3055399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_30
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 
85 0136 spaside cutout template
85 0136 spaside cutout template85 0136 spaside cutout template
85 0136 spaside cutout template
 
85 0135 b-installation manual_web
85 0135 b-installation manual_web85 0135 b-installation manual_web
85 0135 b-installation manual_web
 

54676 mm7 gs100_dca_10_k

  • 1. GS100 Tech Sheet Balboa Water Group System PN 54676 System Model # MM7-GS100-DCA-1.0K Software Version # 41 EPN # 3449 Base PCBA - PN 54677 PCB VS100 - PN 22964 Rev B Base Panels VL200 (Mini) – PN 55123 VL240 (MVP240) – PN 55080 VL260 (MVP260) – PN 55081 VL401 (LCD Lite Duplex) – PN 54665 VL403 (LED Lite Duplex) – PN 54664 Template used: 40749_A.pdf 02/26/2007 54676_97_A.pdf 08/16/2010 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 54676_97_A
  • 2. Basic System Features and Functions Power Requirements • 230VAC, 1~, 16A, 50Hz • 3 wires (line, neutral, ground) System Outputs Setup 1 (As Manufactured) • 230V Pump 1, 2-Speed • 230V Ozone • 10V Spa Light • 230V 1.0kW Heater Additional Options F5, F3A 250V J20 • MoodEFX Lighting K5 G C Connects to Spa Light terminal J20 • FiberEFX Lighting J12 Connects to Spa Light terminal J20 J18 U4 J13 J1 F4 K2 TST RST S1 J6 J43 J7 J8 J9 SWITCHBANK A SEN. A SEN. B http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 54676_97_A
  • 3. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. • Three numbers in a row, which are the SSID (the System Softwar ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if • Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version • Put a jumper across J43, covering both pins. (See illustration below) • Displayed next is: “ ” (indicating the system is configured for • Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is • Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). • Power down again. “ ” should appear for all VS models running at 240VAC. • Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as wel as all GS models. (*A heater which is rated at 4 kW at 240VAC w • Power up again. function as a 1 kW heater at 120VAC.) • “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Refere settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information abou the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. AUX. F VAC MADE IN U.S.A SWITCHBANK A RLY SEN. A SEN. B COPYRIGHT 2005 HEATER SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 54676_97_A
  • 4. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) HIPot Testing Note: Disconnect slip terminal with green • 230V Pump 1, 2-Speed • 230V 1.0kW Heater wires from J90 prior to performing HiPot test. Failure to disconnect will • 10V Spa Light • VL401 Main Panel cause a false failure of the test. • 230V Ozone Reconnect terminal to J90 after successful completion of HiPot test. Ozone runs with Pump 1 low-speed. PUMP OZONE J23 J29 F5, F3A 250V J20 2-Spd P1 G G K5 10V Ozone G C Light J90 C C J50 J12 K4 K1 V F1, T20A 480V J18 F2 U4 J13 T0.25A 250V NEUTRAL J1 W1 J58 J57 K3 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa © 2006 LINE K2 TB1 TST RST S1 J6 J43 NEUTRAL J7 J8 J9 1.0 kW LINE HEATER SEN. A SEN. B SWITCHBANK A WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # Wiring Color Key Neutral (Common) AC Connections 100 Special AC Connections 59 Line AC Connections 41 10 Volt Connections A1, Test Mode OFF A6, 50 Hz J43 Relay Control Wires A2, Un, LT, TD, TU P1, P1, TE, LT A7, Mode changes allowed Memory A8, Degrees C Reset Board Connector Key A4, N/A (must be OFF) A9, P1-low timeout, Table 1 1 A5, P1-high timeout, Table 1 A10, High Amp mode Low Amp mode Typically Line voltage 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Unused 1=Pump 1 3=Temp Down 1 4 Ground 2=Light 1 2=Pump 4=Light 4=Temp Up 1 2 3 4 3 4 2 Note flat sides in connector http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 54676_97_A
  • 5. DIP Switches and Jumpers Definitions SSID 100 59 41 Base Model GS100 DIP Switch Key A1 Test Mode (normally OFF) A2 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up * “OFF” position: Button layout will be: Unused, Pump 1, Temp, Light A3 “ON” position: use Mini Panel * “OFF” position: use Lite Duplex or Digital Duplex panel A4 N/A (must be OFF) A5 Pump 1 high-speed timeout, see Table 1 Table 1 Pump 1 Timeouts A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A5 A9 Low-spd Hi-spd A7 “ON” position: Standard mode only OFF OFF 2 hours 15 min “OFF” position: Std/Ecn/Sleep mode changes allowed ON OFF 2 hours 30 min A8 “ON” position: temperature is displayed in degrees Celsius OFF ON 15 min 15 min “OFF” position: temperature is displayed in degrees Fahrenheit ON ON 30 min 30 min A9 Pump 1 low-speed timeout, see Table 1 A10 “ON” position: heater is disabled while the high-speed pump is running (low amperage mode) “OFF” position: heater can run while the high-speed pump is running (high amperage mode) * Panels with button layout are not compatible when A2 or A3 is ON. Note: No blower or second pump available. Jumper Key J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: •Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. •Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. •Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions 1 A3: OFF 1 2 3 4 3 4 2 A3:ON 1 2 3 4 Panel Button Assignments 1=Unused 3=Temp A2: OFF 2=Pump 1 4=Light A2:ON 1=Pump 1 3=Temp Down 2=Light 4=Temp Up http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 54676_97_A
  • 6. Ozone Connections Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 230VAC 50Hz: L Black or Brown Line Conductor Empty White or Blue Neutral Conductor N Empty Flat sides of sockets as shown PUMP OZONE J23 J29 Not used Circ.Pump G K5 J90 Neutral - White or Blue conductor C Not used Line - Black or Brown conductor J50 K4 K1 F2 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 54676_97_A
  • 7. Duplex Panel Configurations Heat SETUP (AS MANUFACTURED) Jets Light Cool Warm DIP switch A3 must be OFF VL403 (Lite Digital) Heat PN 54664 with Overlay PN 11884 • Connects to Main Panel terminal J1 Jets Light Cool Warm VL401 (Lite Digital) Lite PN 54665 with Overlay PN 11885 • Connects to Main Panel terminal J1 Jets Light Cool Warm DIP switch A3 must be ON VL200 (Mini Panel) PN 55123 with Overlay PN 11852 • Connects to Main Panel terminal J1 OPTIONAL PANELS Jets Light Cool Warm VL240 (MVP240) PN 55080 with Overlay PN 11745 Jets Light Cool Warm • Connects to Main Panel terminal J1 VL260 (MVP260) PN 55081 with Overlay PN 11746 • Connects to Main Panel terminal J1 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 54676_97_A