SlideShare a Scribd company logo
1 of 76
Download to read offline
RVS COLLEGE OF ENGINEERING &TECHNOLOGY
(Approved by AICTE and affiliated to Anna University- Chennai)
Kumaran Kottam., Sulur, Coimbatore - 641402.
DEPARTMENT OF
ELECTRICAL AND ELECTRONICS ENGINEERING
ELECTRICAL MACHINES
LABORATORY LAB MANUAL
R2013
STUDENT NAME : …………………………………..
REGISTER NUMBER : …………………………………..
DEPARTMENT: …………………………………..
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
1
EI6411 ELECTRICAL MACHINES LABORATORY L T P C
0 0 3 2
OBJECTIVE:
To impart hands on experience in verification of circuit laws and theorems, measurement of
circuit parameters, study of circuit characteristics and simulation of time response. To expose
the students to the basic operation of electrical machines and help them to develop experimental
skills.
LIST OF EXPERIMENTS.
1. Open circuit characteristics of D.C. shunt generator.
2. Load characteristics of D.C. shunt generator.
3. Load test on D.C. Shunt Motor.
4. Load test on D.C. Series Motor.
5. Swinburne’s test
6. Speed control of D.C. Shunt Motor.
7. Load test on Single Phase Transformer
8. Open circuit and Short circuit tests on Single Phase Transformer (Determination of
equivalent circuit parameters).
9. Load test on Single Phase Induction Motor.
10. No load and blocked rotor tests on Three Phase Induction Motor (Determination of
equivalent circuit parameters)
11. Load test on Three Phase Induction Motor.
12. Study of Starters
TOTAL: 45 PERIODS
OUTCOME:
Ability to understand and analyze Instrumentation systems and their applications to
various industries.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
2
CYCLE I
CYCLE II
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
3
SUMMARY OF EXPERIMENTS
(Fill in the order by which done)
Ex.No. Date Experiment Name Page No. Mark Staff Signature
1
2
3
4
5
6
7
8
9
10
11
12
Average
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
4
CIRCUIT DIAGRAM FOR OPEN CIRCUIT ON SEPERATELY EXCITED DC GENERATOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
5
OPEN CIRCUIT TEST CHARACTERISTIC OF SEPARATELY
EXCITED DC GENERATOR
AIM:
To conduct the open circuit test on a given separately excited dc generator and
draw the characteristic curves.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1. Voltmeter MC (0-300)V 1
2. Ammeter MC (0-2) A 1
3. Rheostat Wire Wound 400 Ω / 1.1 A 1
4. Rheostat Double element 350 Ω / 2A 1
5. Tachometer Digital - 1
6. Connecting Wires - - As Req.
FUSE RATING:
 110-125% of rated current (full load current).
PRECAUTION:
 The motor field rheostat should be kept at minimum resistance position.
 The generator field rheostat should be kept at maximum resistance position.
FORMULAE USED:
1. Generated voltage Eg = VL + IaRa in Volts.
Where, VL – Load voltage in Volts.
Ia - Armature current in Amps.
Ra - Armature resistance in Ohms.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
6
CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE
TABLE 1: OPEN CIRCUIT TEST
S. No
Field current
(If)
Amps
Open Circuit Voltage
(Eo)
Volts
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
7
PROCEDURE:
OPEN CIRCUIT TEST:
1. Note down the nameplate details of motor.
2. Connections are made as per the circuit diagram shown in diagram.
3. Initially SPST Switch is kept open.
4. Supply is given by closing the DPST Switch in the motor side.
5. Using the DC three point starter, start the motor.
6. The field rheostat of motor is adjusted to run the motor at rated speed.
7. Emf generated due to residual magnetism in the generator is noted along with the zero
value field current.
8. Then, the SPST Switch is closed. Increase the field current in steps of 0.1 Amps by
varying the resistance of the generator field and note down the corresponding open
circuit voltages in Table (1).
TO FIND ARMATURE RESISTANCE:
1. Connections are made as per the circuit diagram shown in diagram.
2. Supply is given by closing the DPST Switch and increase the load step by step.
3. Enter the corresponding ammeter and voltmeter readings in Table (2).
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
8
TABLE 2: TO FIND ARMATURE RESISTANCE
S. No. Current Ia (Amps) Voltage V (Volts) Ra=V/Ia ( )
Average value of R a= 
MODEL GRAPH:
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
9
RESULT:
VIVA QUESTIONS:
1. What is the function of carbon brush used in D.C generator?
2. What is meant by self-excited and separately excited dc generator?
3. What is the basic difference between dc generator and dc motor
4. Write down the emf equation of dc generator. Give the meaning of each symbol.
5. What is critical resistance of a DC shunt generator?
6. What are the conditions to be fulfilled for a shunt generator to build up Voltage?
7. What do you mean by residual flux in DC generator?
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
10
CIRCUIT DIAGRAM FOR LOAD TEST ON SELF EXCITED DC SHUNT GENERATOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
11
LOAD TEST ON SELF EXCITED DC SHUNT GENERATOR
AIM:
To conduct the load test on a given self-excited dc shunt generator and draw the
characteristic curves.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1. Voltmeter MC (0-300)V 1
2. Ammeter MC
(0-10) A
(0-2) A
1
1
3. Rheostat Wire Wound
400 Ω / 1.1 A
360 Ω / 2 A
Each 1
4. Tachometer Digital - 1
5. Connecting Wires - - As Req.
6 Loading Rheostat Wire Wound - 1
FUSE RATING:
 110-125% of rated current (full load current).
PRECAUTIONS:
1. All connections should be perfectly tight and no loose wire should lie on the work
table.
2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its
maximum resistance position.
3. There should be no load on the motor at the time of starting.
4. At the time of starting, the field circuit rheostat is in minimum resistance position.
5. Hold the tachometer with both hands steady and in line with the motor shaft so that it
reads correctly.
FORMULAE USED:
1. Generated voltage (Eg) = VL + Ia Ra in Volts.
Where,
VL- Load voltage in Volts.
Ia- Armature current in Amps & Ra- Armature resistance in Ohms.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
12
CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE
TABLE 1: LOAD TEST
S.No
IL
Amps
If
Amps
Ia= IL- If
Amps
Terminal
Voltage
(VL)
Volts
Ia Ra
Volts
E g =VL + IaRa
Volts
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
13
PROCEDURE:
LOAD TEST:
1. Note down the nameplate details of motor.
2. Connections are made as per the circuit diagram shown diagram.
3. Supply is given by closing the DPST Switch in the motor side.
4. Using the DC three point starter, start the motor.
5. The field rheostat of motor is adjusted to run the motor at rated speed.
6. The generator field rheostat is adjusted for the rated voltage.
7. The DPST switch in the generator side is closed. Increase the resistive load in steps of
2 Amps and note down the corresponding load current and terminal voltage values in
Table (1).
8. Then the resistive load is gradually decreased and the DPST Switch on the generator
side is open. Then the supply is switched off.
9. The generated voltage Eg is calculated by using the formulae as mentioned above and
enter the values in the Table (1).
TO FIND ARMATURE RESISTANCE:
1. Connections are made as per the circuit diagram shown in diagram.
2. Supply is given by closing the DPST switch and increases the load step by step.
3. Enter the corresponding ammeter and voltmeter readings in Table (2).
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
14
TABLE 2: TO FIND ARMATURE RESISTANCE.
S. No.
Current
Ia
(Amps)
Voltage
V
(Volts)
Ra=V/Ia
( )
Average value of R a= 
MODEL GRAPH:
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
15
RESULT:
VIVA QUESTIONS:
1. State the various types of DC generators.
2. List the main parts of DC machine.
3. State the applications of various types of DC generators.
4. What is residual voltage?
5. Difference between self-excited and separately excited of DC generator.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
16
CIRCUIT DIAGRAM FOR LOAD TEST ON D.C SHUNT MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
17
LOAD TEST ON DC SHUNT MOTOR
AIM:
To conduct the load test on DC shunt motor and draw the characteristic curves.
APPARATUS REQUIRED:
S. No APPARATUS TYPE RANGE QUANTITY
1 Ammeter MC (0-20) A 1
2 Voltmeter MC (0-300) V 1
3 Tachometer Digital - 1
4 Rheostat Wire Wound
wound
400 Ω/ 1.1 A 1
5 Connecting Wires - - As Req.
FUSE RATING:
 110-125% of rated current (full load current).
PRECAUTIONS:
1. All connections should be perfectly tight and no loose wire should lie on the work
table.
2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its
maximum resistance position.
3. There should be no load on the motor at the time of starting.
4. At the time of starting, the field circuit rheostat is in minimum resistance position.
5. Hold the tachometer with both hands steady and in line with the motor shaft so that it
reads correctly.
FORMULAE USED:
1. Torque T = (S1~S2) × (R) × 9.81 in N-m.
Where,
R- Radius of the Brake drum in m.
t- Thickness of the Belt in m.
S1, S2- Spring balance reading in Kg.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
18
TABULATION:
Radius of the brake drum:
S. No
Load
Current
(IL)
Amps
Load
Voltage
( VL )
Volts
Input
Power
( Pi )
Watts
Speed
( N )
rpm
Spring Balance Reading
(Kg)
Torque
(T)
N-m
Input
Power
(Pin)
Watts
Output
Power
(PO)
Watts
Efficiency
( η )
%
S1 S2 S1~S2
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
19
2. Input power = VL × IL in Watts.
Where,
VL - Load Voltage in Volts.
IL -Load current in Amps.
3. Output power = 2πNT/60 in Watts.
Where,
N- Speed of the armature in rpm.
T- Torque in N-m.
4. Percentage of Efficiency = (Output power/Input power) × 100.
PROCEDURE:
1. Connections are given as per the circuit diagram.
2. Using the three-point starter the motor is started to run at the rated speed by adjusting
the field rheostat if necessary.
3. The meter readings are noted at no load condition.
4. By using the Brake drum with spring balance arrangement the motor is loaded and the
corresponding readings are noted up to the rated current.
5. After the observation of all the readings the load is released gradually.
6. Load is gradually decreased and field rheostat is brought to the minimum resistance
position and the supply is switched off.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
20
MODEL GRAPH:
Electrical Characteristics Mechanical Characteristics
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
21
RESULT:
VIVA QUESTION:
1. How do you load the motor in this experiment?
2. What was the assumption made in calculations?
3. What is the condition for maximum torque of a D.C. shunt motor?
4. Why is the starter necessary?
5. What is the power factor of the load used?
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
22
CIRCUIT DIAGRAM FOR LOAD TEST ON D.C. SERIES MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
23
LOAD TEST ON D.C. SERIES MOTOR
AIM:
To conduct load test on DC series motor and determine the load characteristics.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1. Voltmeter MC (0-300V) 1
2. Ammeter MC (0-20A) 1
3. Tachometer Digital - 1
4. Connecting wires - - As Req.
PRECAUTIONS:
 The series motor should be started with some minimum load.
 Water should be poured in the hollow portion of brake drum.
 Motor should be stopped with some minimum load.
 After shut down, the load should be fully released, so as to make the drum free of cool.
FORMULAE USED:
1. Torque applied on the motor, T = (S1~S2) x r x 9.81 Nm.
2. Input Power (Pi) = VL x IL Watts.
Output, P0 = (2πNT)/60 Watts.
3. % Efficiency, η = (Po/Pi) x 100.
Where,
Circumference of the brake drum, 2 πr = ---------- m2
Radius of the brake drum, r = ---------- m
S1&S2 spring balance readings in kg.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
24
TABULATION:
Sl. No
Line
voltage
VL Volts
Line
current
IL
Amps
Speed
N
(rpm)
Spring balance
reading
Torque
T (N.m)
Output Power
P0
Watts
Input Power
Pi
Watts
% Efficiency
η
S1
Kg
S2
Kg
1
2
3
4
5
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
25
PROCEDURE:
1. Connections are made as per the circuit diagram.
2. Supply is given by closing DPSTS.
3. Start the motor using the starter.
4. Note down the readings for varying load conditions and plot the graph.
MODEL CALCULATION:
RESULT:
VIVA QUESTIONS:
1. Why the series motor is started with some minimum load?
2. What are the applications of D.C. series motor?
3. Why series motors are used for traction purpose?
4. While running, if series field winding is opened what happens?
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
26
CIRCUIT DIAGRAM FOR SWINBURN’S TEST
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
27
SWINBURNE’S TEST
AIM:
To predetermine the efficiency of a given dc shunt machine when working as a motor
as well as generator by Swinburne’s test and also draw the characteristic curves.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1. Voltmeter MC
( 0-300 ) V
( 0-50 ) V
1
1
2. Ammeter MC
(0-5) A
(0-2) A
1
1
3. Rheostat
Wire
Wound
400 Ω / 1.1 A 1
4 Loading Rheostat
Wire
Wound
50 Ω / 5 A 1
5. Tachometer Digital - 1
6. Connecting Wires - - As Req
FUSE RATING:
 110-125% of rated current (full load current).
PRECAUTIONS:
1. All connections should be perfectly tight and no loose wire should lie on the work
table.
2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its
maximum resistance position.
3. There should be no load on the motor at the time of starting.
4. At the time of starting, the field circuit rheostat is in minimum resistance position.
5. Hold the tachometer with both hands steady and in line with the motor shaft so that it
reads correctly.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
28
CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE
TABLE 1: TO FIND CONSTANT LOSSES
TABLE 2: TO FIND ARMATURE RESISTANCE ‘R a’
S.NO INPUT
SUPPLY
VOLTAGE
(Volts)
NO LOAD
CURRENT
I 0
(Amps)
FIELD
CURRENT
I f
(Amps)
ARMATURE
CURRENT
Iao = I 0 - I f
(Amps)
CONSTANT
LOSSES
Wo
= VI 0 – I ao
2 R a
(Watts)
S.NO CURRENT
Ia
( Amps )
VOLTAGE
V
( Volts )
ARMATURE RESISTANCE
Rdc = V / I a
(Ohms)
1.
2.
3.
4.
5.
Average value of Ra =
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
29
FORMULAE USED:
1. Armature Current on no load, I ao = I0 – I f
2. Constant losses, W c = VI 0 – I ao
2
Ra
3. Armature resistance, Ra = V / I a
MOTOR ACTION:
1. Load current = IL
2. Armature current , I a = IL – I f
3. Armature Copper loss = I a
2
Ra
4. Total losses = Wc + I a
2
Ra
5. Input = V I
6. Output = Input – Losses
7. Efficiency,  = (Output / Input) x 100
GENERATOR ACTION:
1. Armature Current I a = IL + I f
2. Armature Copper loss = I a
2
R a
3. Total losses = W c + I a
2
R a
4. Output = V I
5. Input = Output + Losses
6. Efficiency,  = (Output / Input) x 100
PROCEDURE:
NO LOAD TEST:
1. Note the name plate details of the machine.
2. The connections are made as per circuit diagram.
3. Close the DPST switch.
4. Start the motor by using three-point starter.
5. Adjust the speed to rated speed by increasing field circuit resistance (Field rheostat).
6. Enter the input voltage, No load current and field current in Table (1).
TO FIND Ra:
1. The connections are made as per circuit diagram shown in diagram.
2. Close the DPST switch and increase the load step by step.
3. Enter the corresponding ammeter and voltmeter readings in Table (2).
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
30
TABLE (3): CALCULATION OF EFFICIENCY AS A MOTOR:
Constant Loss: Calculated value from Table (1)
TABLE (4): CALCULATION OF EFFICIENCY AS A GENERATOR:
S.
No Load Current
I
(Amps)
Armature
Current
Ia = I - I f
(Amps)
Armature
Copper loss
= I a
2 R a
(Watts)
Total Losses
= Wo+ I a
2 R a
(Watts)
Input
V I
(Watts)
Output =
Input – losses
(Watts)
Efficiency
=(output/
input)x100
(Percentage)
1. ¼ th
of
rated value
2. ½ th
of
rated value
3. ¾ th
of
rated value
4. Rated value
S.
No
Load
Current
I
(Amps)
Armature
Current
Ia = I + I f
(Amps)
Armature
Copper loss
= I a
2 R a
(Watts)
Total Losses
= Wo+ I a
2 R a
(Watts)
Output
V I
(Watts)
Input =
Output + Losses
(Watts)
Efficiency
=(output/
Input)x100
(Percentage)
1. ¼ th
of
rated value
2. ½ th
of
rated value
3. ¾ th
of
rated value
4. Rated value
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
31
MODEL GRAPH:
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
32
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
33
RESULT:
VIVA QUESTION:
1. What is the function of no-volt release coil in 3point starters?
2. How to change the direction of rotation of d.c motor?
3. Swinburne‘s test is also called?
4. List the various losses in d.c machine.
5. Name the various methods of testing the d.c machine.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
34
CIRCUIT DIAGRAM FOR SPEED CONTROL OF DC SHUNT MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
35
SPEED CONTROL OF DC SHUNT MOTOR
AIM:
To control the speed of the given DC shunt motor by field and armature control methods
and also to draw their characteristics curves.
APPARATUS REQUIRED:
S. No APPARATUS TYPE RANGE QUANTITY
1 Ammeter MC (0-2) A 1
2 Voltmeter MC (0-300) V 1
3 Tachometer Digital - 1
4 Rheostat Wire Wound 400 Ω/ 1.1 A 1
5 Rheostat Wire wound 50 Ω/ 5 A 1
6 Connecting Wires - -- As Req
FUSE RATING:
 110-125% of rated current (full load current).
PRECAUTIONS:
 All connections should be perfectly tight and no loose wire should lie on the work table.
 There should be no load on the motor at the time of starting.
 At the time of starting, the field circuit rheostat is in minimum resistance position and
armature rheostat is in maximum position.
 Hold the tachometer with both hands steady and in line with the motor shaft so that it
reads correctly.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
36
TABLE 1: FIELD CONTROL METHOD.
Rated Speed:
TABLE 2: ARMATURE CONTROL METHOD
Rated Speed:
S.NO.
Armature Voltage (Va)=
Speed (N)
(Rpm)
Field Current (If)
(Amps)
S.NO
Field Current(If)=
Speed (N)
(Rpm)
Armature Voltage
(Va)
(Volts)
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
37
PROCEDURE:
Field current (or) flux control method:
1. Note down the name plate details of the motor.
2. Connections are made as per circuit diagram.
3. The motor run at rated speed by adjusting the armature and field rheostat.
4. Keep the armature voltage constant at rated value.
5. Increase the speed in steps of 50 rpm above the rated speed using field rheostat and note
down the corresponding field current values in Table (1).
Armature (or) voltage control method:
1. Note down the name plate details of the motor.
2. Connections are made as per circuit diagram.
3. The motor run at rated speed by adjusting the armature and field rheostat.
4. Keep the field current constant at rated speed.
5. Decrease the speed in steps of 50 rpm below the rated speed using armature rheostat
and note down the corresponding field current values in Table (2).
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
38
MODEL GRAPH:
Armature Control Method Field Control Method
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
39
RESULT:
VIVA QUESTION:
1. What are the limitations of armature voltage control and field current control methods?
2. Why both rheostats are kept at minimum resistance position in the starting condition?
3. What is starter? Why is it required?
4. What are the applications of dc shunt motor?
5. Why brushes are made from carbon?
6. Why is thin conductor used for field winding? & thick conductor for armature winding?
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
40
CIRCUIT DIAGRAM FOR LOAD TEST ON SINGLE PHASE TRANSFORMER
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
41
LOAD TEST ON SINGLE PHASE TRANSFORMER
AIM:
To conduct the load test on a given single phase transformer and draw its performance
curves.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1 Ammeter MI
(0-5)A 1
(0-10)A 1
2 Voltmeter MI
(0-300)V 1
(0-150)V 1
3 Wattmeter UPF 300V,5A 1
4 1φ auto transformer 230/(0-270)V 1
5 1φ step down transformer 230/110V,1KVA 1
6 Loading Rheostat Wire Wound 1
7 Tachometer Digital 1
8 Connecting wires - - As required
9 DPST - - 1
FUSE RATING:
 Primary Current = KVA Rating of the Transformer / Primary Voltage.
 Secondary Current = KVA Rating of the Transformer / Secondary Voltage.
 110-125% of Primary current (fuse rating for primary side).
 110-125% of Secondary current (fuse rating for secondary side).
PRECAUTIONS:
 At the time of starting, the DPST switch on secondary side should be kept in open
condition.
 At the time of starting, there should be no load on the loading rheostat.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
42
Table: Load Test on Single Phase Transformer.
Multiplication Factor =
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
43
FORMULAE:
1. Output power = Vs x Is x CosΦ in Watts.
Where,
Vs – Secondary voltage in volts.
Is – secondary current in amps.
Cos Φ - power factor.
2. Input Power = Wattmeter reading in Watts.
3. Efficiency = (output power/Input power) X 100 %
4. Voltage Regulation = [(V no load - V load) / (V load)] X100 %
Where,
V no load – no load voltage in volts.
V load – load voltage in volts.
PROCEDURE:
1. Connections are given as per the circuit diagram.
2. The SPST Switch on the Primary side is closed and the DPST Switch on the Secondary
side is opened.
3. The Autotransformer is adjusted to energize the transformer with rated Primary
Voltage.
4. The Volt meters and Ammeters Readings are noted and tabulated at No load condition.
5. The DPST switch on the secondary side is closed.
6. The transformer is loaded up to 130% of the Rated Load, corresponding Ammeters,
Voltmeters and Wattmeter readings are noted and tabulated.
7. After the observation of all the readings the load is released gradually to its initial
position.
8. The Autotransformer is brought to its initial position.
9. The Supply is switched off.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
44
MODEL GRAPH:
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
45
RESULT:
VIVA QUESTIONS:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
46
CIRCUIT DIAGRAM FOR OPEN CIRCUIT TEST ON SINGLE PHASE TRANSFORMER
Tabulation for OC test on Single phase transformer
Multiplication Factor =
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
47
OPEN CIRCUIT TEST AND SHORT CIRCUIT TEST
ON SINGLE PHASE TRANSFORMER
AIM:
To Predetermine the Efficiency and Regulation on a given single phase
transformer by conducting the Open Circuit test and Short Circuit test and also draw its
Equivalent circuit.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1 Ammeter MI
(0-1)A, (0-5A)
(0-10A)
Each 1
2 Voltmeter MI
(0-300)V 1
(0-150)V 1
3 Wattmeter LPF
UPF
150V,1A
150V,5A
Each 1
4 1φ auto transformer 230/(0-270)V 1
4 1φ Taping transformer 230/110V,1KVA 1
5 Tachometer Digital - 1
6 Connecting wires - - As required
FUSE RATING:
 Primary Current = KVA Rating of the Transformer / Primary Voltage.
 Secondary Current = KVA Rating of the Transformer / Secondary Voltage.
 110-125% of Primary current (fuse rating for primary side).
 110-125% of Secondary current (fuse rating for secondary side).
PRECAUTIONS:
 At the time of starting, the auto transformer should be in the minimum voltage
position.
 For O.C test, the HV side of the transformer is in open circuit condition.
 For S.C test, the LV side of the transformer is short circuited.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
48
CIRCUIT DIAGRAM FOR SHORT CIRCUIT TEST ON SINGLE PHASE TRANSFORMER
Tabulation for SC test on Single phase transformer
Multiplication Factor =
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
49
FORMULAE USED:
O.C Test:
1. No load Power factor, Cos Φo = [ Woc / ( Voc x I oc ) ]
Where, Woc – No load losses.
Voc – No load voltage.
I oc – No load current.
2. Magnetizing component, Im = I oc x Sin Φo
3. Working component, Iw = I oc x Cos Φo
4. No load resistance, R 0 = V oc / Iw in ohms
5. No load reactance, X 0 = V oc / Im in ohms
S.C Test.
1. Primary winding resistance, R1 = Wsc / Isc
2
in ohms
Where, Wsc - Short circuit power in Watts
Isc - Short circuit current in Amps
2. Primary winding impedance, Z1 = Vsc / Isc in ohms
where, V sc = Short circuit voltage in Volts
3. Primary winding reactance, X1 = Z1
2
- R1
2
in ohms
4. Secondary winding resistance, R 2 = W sc / I sc
2
in ohms
5. Secondary winding impedance , Z 2 = V sc / Isc in ohms
6. Secondary winding reactance , X2 = Z 2
2
– R2
2
in ohms
7. Transformation ratio ( K ) = V 2 / V 1
8. Equivalent secondary resistance referred to primary side,
R2 ‘ = R2 / K 2
in ohms.
9. Equivalent secondary reactance referred to primary side,
X2 ‘ = X2 / K 2
in ohms.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
50
TO CALCULATE THE EFFICIENCY:
Iron loss (Wi): Calculated from Table (1)
Short Circuit loss (Wsc): Calculated from Table (2)
S.NO LOAD
FRACTION
X
IRON
LOSS
Wi
(Watts)
COPPER
LOSS
X2 WSC
(Watts)
TOTAL
LOSS
W
(Watts)
OUTPUT
POWER
PO
(Watts)
INPUT
POWER
Pi
(Watts)
EFFICIENCY
η
(%)
UPF PF=0.8 UPF PF=0.8 UPF PF=0.8
1 0.25
2 0.5
3 0.75
4 1.00
5 1.25
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
51
EFFICIENCY:
1. Iron loss, wi = woc in Watts.
Where, Woc - No load loss.
2. Copper loss, Wc - x2
WSC in Watts.
Where, x - Fraction of load.
WSC - Short circuit losses.
3. Total loss, W = Wi + Wc in Watts.
4. Output power, Po = x X kVA X Cos Φ
5. Where,
Cos Φ – power factor.
Cos Φ= 1 for UPF.
Cos Φ= 0.8 for LPF.
6. Input power, Pi = Po+ W in Watts.
7. Efficiency, η = (Po / Pi) X 100 %
REGULATION:
1. Percentage Regulation
= [x Isc / VOC ( R01 Cos Φ ± X01 Sin Φ ) ] x 100 %
+ Lagging Leading
2. Total resistance as referred to primary side, R01= R1 + R2 ‘in ohms.
3. Total reactance as referred to primary side, X01 = X1+ X2 ‘in ohms.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
52
Resultant Tabulation to find out the Efficiency:
Core (Or) Iron Loss = A Rating of Transformer =
Rated Short Circuit Current (ISC) = Short Circuit Power (WSC) =
Resultant Tabulation to find out the Regulation:
POWERFACTOR
COS Φ
125% LOAD, X = 1.25 100% LOAD, X = 1 75% LOAD, X = 0.75
LAG LEAD LAG LEAD LAG LEAD
0.2
0.4
0.6
0.8
1
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
53
PROCEDURE:
OPEN CIRCUIT TEST:
1. Connections are given as per the circuit diagram.
2. The SPST Switch on the Primary side is closed.
3. The Autotransformer is adjusted to Energize the transformer with rated Primary
Voltage on the LV side
4. The Volt meter, Watt meter and Ammeter Readings are noted at No load condition
5. The Autotransformer is brought to its initial position
6. The Supply is switched off.
SHORT CIRCUIT TEST:
1. Connections are given as per the circuit diagram.
2. The SPST Switch on the Primary side is closed
3. The Autotransformer is adjusted to energize the transformer with rated Primary Current
on the HV side.
4. The Voltmeter, Wattmeter and Ammeter Readings are noted down at short circuit
condition.
5. The Autotransformer is brought to its initial position
6. The Supply is switched off.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
54
EQUIVALENT CIRCUIT FOR SINGLE PHASE TRANSFORMER
MODEL GRAPH:
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
55
RESULT:
VIVA QUESTIONS:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
56
CIRCUIT DIAGRAM FOR LOAD TEST ON SINGLE PHASE INDUCTION MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
57
LOAD TEST ON SINGLE PHASE INDUCTION MOTOR
AIM:
To determine the performance characteristic of a given single phase capacitor start
induction motor by conducting load test.
APPARATUS REQUIRED:
FUSE RATING:
 Fuse rating = 125% of rated current.
PRECAUTION:
 Before switching on the supply the single phase auto transformer is kept in minimum
position.
 Initially these should be on no load while starting the motor.
FORMULA USED:
1. Torque, T = (S1~S2)*9.81*R N.m.
2. Output power = 2π NT/60*W
3. Effecting (η%) = 0/P Power/I/p Power*100
4. Slip (%S) = NS – N/NS*100
5. Power factor = Cos φ=W/VI
PROCEDURE:
1. Connections are given as per the circuit diagram.
2. Switch on the supply at no load condition.
3. Apply the rated voltage to the motor using the single phase auto transformer and note
down the readings at ammeter and wattmeter.
4. Vary the load in suitable steps and note down all the meter readings till full load
condition.
SL. NO APPARATUS RANGE TYPE QUANTITY
1 Voltmeter (0-300) V MI 1
2 Ammeter (0-20) A MI 1
3 Wattmeter 300 V, 20 A UPF 1
4 Tachometer - Digital 1
5 1φ auto transformer 230V/0-270V 1
6 Connecting wires - - As Req.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
58
TABLULATION: M.F =
MODEL CALCULATION:
Sl.No.
VL
(V)
IL
(A)
Speed(N)
(Rpm)
S1
(Kg)
S2
(Kg)
S1 ̃~ S2
(Kg)
Torque
(N-m)
Wattmeter Reading Output
Power
(W)
Efficiency
η%
PF=cosΦ
%Slip
Obs.
(W)
Actual
(W)
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
59
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
60
MODEL GRAPH:
ELECTRICAL CHARACTERISTICS:
MECHANICAL CHARACTERISTICS:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
61
RESULT:
VIVA QUESTIONS:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
62
CIRCUIT DIAGRAM FOR NO LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
63
EQUIVALENT CIRCUIT OF THREE PHASE SQUIRREL
CAGE INDUCTION MOTOR
AIM:
To conduct a No Load test and Blocked Rotor test on three phase squirrel cage induction
motor and to draw the equivalent circuit.
APPARATUS REQUIRED:
S.NO APPARATUS TYPE RANGE QUANTITY
1 Ammeter MI (0-5A),
(0-10A)
Each 1
2 Voltmeter MI (0-600)V 1
3 Wattmeter UPF,LPF 600V,5A
150V,10A
Each 1
4 3φ auto transformer 415/(0-470)V 1
5 Tachometer Digital - 1
6 Connecting wires - - As required
FUSE RATING:
 No Load: 10 % of rated current (Full load current).
 Load: 110-125 % of rated current (Full load current).
PRECAUTION:
 The autotransformer should be kept at minimum voltage position.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
64
CIRCUIT DIAGRAM FOR BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE
INDUCTION MOTOR (Equivalent circuit)
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
65
FORMULAE USED:
OC TEST:
1. No load power factor (Cos φ 0) = P0/V0I0
V0 - No load voltage per phase in volts.
I0 - No load current per phase in amps.
P0 - No load power per phase in watts.
2. Working component current (Iw) = I0 (ph) X Cos φ 0
3. Magnetizing current (Im) = I0 (ph) X Sin φ 0
4. No load resistance (R0) =V0/I0 (ph) Cos φ 0 in W.
5. No load reactance (X0) = V0/I0 (ph) Sin φ 0 in W.
SC TEST:
1. Motor equivalent Impedance referred to stator (Zsc(ph)) = Vsc(ph) / Isc(ph) in Ω.
2. Motor equivalent Resistance referred to stator (Rsc(ph)) = Psc(ph) / I2
sc(ph) in Ω.
3. Motor equivalent Reactance referred to stator (Xsc(ph)) = √(Z sc(ph)2
- Rsc(ph)2
) in Ω.
4. Rotor Resistance referred to stator (R2’(ph)) = Rsc(ph) – R1 in Ω.
5. Rotor Reactance referred to stator (X2’(ph)) = Xsc(ph) / 2 = X1 in Ω.
Where, R1 - stator resistance per phase.
X1 – stator reactance per chapter.
R1 = R(ac) =1.6 x R(dc).
6. Equivalent load resistance (RL’) = R2’ (1/s – 1) in Ω.
Where, Slip (S) = (Ns-Nr) / Ns.
Ns – Synchronous speed in rpm.
Nr – Rotor speed in rpm.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
66
TABULATION FOR NO LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
Speed of the Induction motor:
Type of the Stator connection:
Multiplication Factor:
TABULATION FOR BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
Type of the Stator connection:
Multiplication Factor:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
67
PROCEDURE:
1. Connections are given as per the circuit diagram.
2. For No-Load or open circuit test by adjusting autotransformer, apply rated voltage and
Note down the voltmeter, ammeter and wattmeter readings. In this test rotor is free to
rotate.
3. For short circuit or blocked rotor test by adjusting autotransformer, apply rated current
and note down the voltmeter ,ammeter and wattmeter readings. In this test rotor is
blocked.
4. After that make the connection to measure the stator resistance as per the circuit
diagram.
5. By adding the load through the loading rheostat note down the ammeter, voltmeter
reading for various values of load.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
68
EQUIVALENT CIRCUIT FOR THREE PHASE SQUIRREL CAGE
INDUCTION MOTOR
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
69
RESULT:
VIVAQUESTION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
70
CIRCUIT DIAGRAM FOR LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR
FUSE RATING
125% of rated current.
NAME PLATE DETAILS
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
71
LOAD TEST ON THREE PHASE SQUIRREL CAGE
INDUCTION MOTOR
AIM:
To conduct a load test on a three phase squirrel cage induction motor and to draw the
performance characteristic curves.
APPARATUS REQUIRED:
FUSE RATING:
 110-125% of rated current (Full load current).
PRECAUTIONS:
 There should be no load on the motor at the time of starting.
FORMULAE USED:
1. Torque = (S1-S2) (R+t/2) x 9.81 N-m
Where, S1, S2 – spring balance readings in Kg.
R - Radius of brake drum in m.
t - Thickness of belt in m.
Output Power = 2 PNT/60 watts.
N- Rotor speed in rpm.
T- Torque in N-m.
2. Input Power = (W1+W2) Watts.
W1, W2 – Wattmeter readings in Watts.
3. Percentage of Efficiency = (Output Power/ Input Power) x 100%.
S.NO APPARATUS TYPE RANGE QUANTITY
1 Ammeter MI (0-5/10)A 1
2 Voltmeter MI (0-600)V 1
3 Wattmeter UPF 600V,5/10A 2
4 Tachometer Digital 1
5 Connecting wires - - As required
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
72
TABULATION FOR LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR.
Multiplication Factor:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
73
4. Percentage of Slip = (NS-Nr)/Ns x 100%
Ns-Synchronous speed in rpm.
Nr-Rotor speed in rpm.
5. Power factor = (W1+W2)/ √ 3 VLIL.
PROCEDURE:
1. Connections are given as per the circuit diagram.
2. The TPSTS is closed and the motor is started using On Line starter to run at rated speed.
3. At no load the speed, current, voltage and power are noted down.
4. By applying the load for various values of current the above-mentioned readings are
noted.
5. The load is later released and the motor is switched off and the graph is drawn.
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
74
MODEL GRAPHS:
Mechanical Characteristics Electrical Characteristics
MODEL CALCULATION:
Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013
75
RESULT:
VIVA QUESTION:

More Related Content

What's hot

transformer slide prsentation
transformer slide prsentation transformer slide prsentation
transformer slide prsentation abu jubayer
 
Servomechanism in Control systems engineering
Servomechanism in Control systems engineeringServomechanism in Control systems engineering
Servomechanism in Control systems engineeringNisarg Amin
 
Speed control of Three phase Induction motor using AC voltage regulator
Speed control of Three phase Induction motor using AC voltage regulatorSpeed control of Three phase Induction motor using AC voltage regulator
Speed control of Three phase Induction motor using AC voltage regulatorShivagee Raj
 
Unit 03 Construction & Operation of Watt meter & Energy meter
Unit   03 Construction & Operation of Watt meter & Energy meterUnit   03 Construction & Operation of Watt meter & Energy meter
Unit 03 Construction & Operation of Watt meter & Energy meterPremanandDesai
 
Silicon controlled rectifier
Silicon controlled rectifierSilicon controlled rectifier
Silicon controlled rectifierpavan chauda
 
Power electronics Phase Controlled Rectifiers - SCR
Power electronics   Phase Controlled Rectifiers - SCRPower electronics   Phase Controlled Rectifiers - SCR
Power electronics Phase Controlled Rectifiers - SCRBurdwan University
 
Instrument Transformer Presentation
Instrument Transformer PresentationInstrument Transformer Presentation
Instrument Transformer PresentationRishi Raj
 
Electrical and electronics Lab Manual
Electrical and electronics Lab ManualElectrical and electronics Lab Manual
Electrical and electronics Lab ManualSachin Airan
 
Single phase transformer
Single phase transformerSingle phase transformer
Single phase transformerMahendra Rajput
 
Unit-1 Power Semiconductor devices
Unit-1 Power Semiconductor devicesUnit-1 Power Semiconductor devices
Unit-1 Power Semiconductor devicesjohny renoald
 
Induction motor
Induction motorInduction motor
Induction motorAL- AMIN
 
Power Electronics SCR and BJT MCQ Questions
Power Electronics SCR and BJT MCQ QuestionsPower Electronics SCR and BJT MCQ Questions
Power Electronics SCR and BJT MCQ QuestionsBurdwan University
 
Different methods of pwm for inverter control
Different methods of pwm for inverter controlDifferent methods of pwm for inverter control
Different methods of pwm for inverter controlTushar Pandagre
 
Relay Presentation PPT by G@nesh
Relay Presentation PPT by G@neshRelay Presentation PPT by G@nesh
Relay Presentation PPT by G@neshKOMMARINASANTHOSH
 

What's hot (20)

transformer slide prsentation
transformer slide prsentation transformer slide prsentation
transformer slide prsentation
 
Servomechanism in Control systems engineering
Servomechanism in Control systems engineeringServomechanism in Control systems engineering
Servomechanism in Control systems engineering
 
Speed control of Three phase Induction motor using AC voltage regulator
Speed control of Three phase Induction motor using AC voltage regulatorSpeed control of Three phase Induction motor using AC voltage regulator
Speed control of Three phase Induction motor using AC voltage regulator
 
Unit 03 Construction & Operation of Watt meter & Energy meter
Unit   03 Construction & Operation of Watt meter & Energy meterUnit   03 Construction & Operation of Watt meter & Energy meter
Unit 03 Construction & Operation of Watt meter & Energy meter
 
Silicon controlled rectifier
Silicon controlled rectifierSilicon controlled rectifier
Silicon controlled rectifier
 
Current Transformer
Current TransformerCurrent Transformer
Current Transformer
 
Power electronics Phase Controlled Rectifiers - SCR
Power electronics   Phase Controlled Rectifiers - SCRPower electronics   Phase Controlled Rectifiers - SCR
Power electronics Phase Controlled Rectifiers - SCR
 
Instrument Transformer Presentation
Instrument Transformer PresentationInstrument Transformer Presentation
Instrument Transformer Presentation
 
Electrical and electronics Lab Manual
Electrical and electronics Lab ManualElectrical and electronics Lab Manual
Electrical and electronics Lab Manual
 
Motor starter
Motor starterMotor starter
Motor starter
 
Single phase transformer
Single phase transformerSingle phase transformer
Single phase transformer
 
DC GENERATOR
DC GENERATORDC GENERATOR
DC GENERATOR
 
Triac (industrial electronic)
Triac (industrial electronic)Triac (industrial electronic)
Triac (industrial electronic)
 
Speed control of dc motor
Speed control of dc motorSpeed control of dc motor
Speed control of dc motor
 
armature Winding
armature Windingarmature Winding
armature Winding
 
Unit-1 Power Semiconductor devices
Unit-1 Power Semiconductor devicesUnit-1 Power Semiconductor devices
Unit-1 Power Semiconductor devices
 
Induction motor
Induction motorInduction motor
Induction motor
 
Power Electronics SCR and BJT MCQ Questions
Power Electronics SCR and BJT MCQ QuestionsPower Electronics SCR and BJT MCQ Questions
Power Electronics SCR and BJT MCQ Questions
 
Different methods of pwm for inverter control
Different methods of pwm for inverter controlDifferent methods of pwm for inverter control
Different methods of pwm for inverter control
 
Relay Presentation PPT by G@nesh
Relay Presentation PPT by G@neshRelay Presentation PPT by G@nesh
Relay Presentation PPT by G@nesh
 

Viewers also liked

POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS)
POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS) POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS)
POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS) Mathankumar S
 
Power System Modelling And Simulation Lab
Power System Modelling And Simulation LabPower System Modelling And Simulation Lab
Power System Modelling And Simulation LabSachin Airan
 
Electrical machines 2 lab manual
Electrical machines 2 lab manualElectrical machines 2 lab manual
Electrical machines 2 lab manualNaga Sai Chaitanya
 
Engr2200 lab manual_lab2_
Engr2200 lab manual_lab2_Engr2200 lab manual_lab2_
Engr2200 lab manual_lab2_Mherub Ahsan
 
Introduction to Electrical Engineering Laboratory
Introduction to Electrical Engineering LaboratoryIntroduction to Electrical Engineering Laboratory
Introduction to Electrical Engineering LaboratoryIsuru Premaratne
 
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )Mathankumar S
 
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...Parhamsagharchi
 
Em ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestEm ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestraj_e2004
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUALAJAL A J
 
Engineering practice lab manual for electronics
Engineering practice lab manual for electronicsEngineering practice lab manual for electronics
Engineering practice lab manual for electronicsPadhu Ar
 
Exp 5 (1)5. Newton Raphson load flow analysis Matlab Software
Exp 5 (1)5.	Newton Raphson load flow analysis Matlab SoftwareExp 5 (1)5.	Newton Raphson load flow analysis Matlab Software
Exp 5 (1)5. Newton Raphson load flow analysis Matlab SoftwareShweta Yadav
 
Circuit Analysis Lab
Circuit Analysis LabCircuit Analysis Lab
Circuit Analysis LabSachin Airan
 
Matlab simpowersystem
Matlab simpowersystemMatlab simpowersystem
Matlab simpowersystemAmeen San
 
Ee 444 electrical drives be(tx) 2012
Ee 444 electrical drives be(tx) 2012Ee 444 electrical drives be(tx) 2012
Ee 444 electrical drives be(tx) 2012AZMAT ABBAS RANA
 
EC 2 lab manual with circulits
EC 2 lab manual with circulitsEC 2 lab manual with circulits
EC 2 lab manual with circulitsMurugan Dhandapani
 
Lab 02 Resistor color coding and ohms law
Lab 02   Resistor color coding and ohms lawLab 02   Resistor color coding and ohms law
Lab 02 Resistor color coding and ohms lawHassaan Rahman
 
MATLAB programs Power System Simulation lab (Electrical Engineer)
MATLAB programs Power System Simulation  lab (Electrical Engineer)MATLAB programs Power System Simulation  lab (Electrical Engineer)
MATLAB programs Power System Simulation lab (Electrical Engineer)Mathankumar S
 

Viewers also liked (20)

POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS)
POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS) POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS)
POWER SYSTEM SIMULATION - 2 LAB MANUAL (ELECTRICAL ENGINEERING - POWER SYSTEMS)
 
Power System Modelling And Simulation Lab
Power System Modelling And Simulation LabPower System Modelling And Simulation Lab
Power System Modelling And Simulation Lab
 
Electrical machines 2 lab manual
Electrical machines 2 lab manualElectrical machines 2 lab manual
Electrical machines 2 lab manual
 
Engr2200 lab manual_lab2_
Engr2200 lab manual_lab2_Engr2200 lab manual_lab2_
Engr2200 lab manual_lab2_
 
Introduction to Electrical Engineering Laboratory
Introduction to Electrical Engineering LaboratoryIntroduction to Electrical Engineering Laboratory
Introduction to Electrical Engineering Laboratory
 
Modeling and Simulation Lab Manual ME PED
Modeling and Simulation Lab Manual ME PEDModeling and Simulation Lab Manual ME PED
Modeling and Simulation Lab Manual ME PED
 
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )
POWER SYSTEM SIMULATION LAB-1 MANUAL (ELECTRICAL - POWER SYSTEM ENGINEERING )
 
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...
NUMERICAL METHODS WITH MATLAB : bisection,mueller's,newton-raphson,false poin...
 
Resistor color coding
Resistor color codingResistor color coding
Resistor color coding
 
pe lab manual
pe lab manualpe lab manual
pe lab manual
 
Em ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latestEm ii lab manual 28.10.08 latest
Em ii lab manual 28.10.08 latest
 
Analog electronics LAB MANUAL
Analog electronics LAB MANUALAnalog electronics LAB MANUAL
Analog electronics LAB MANUAL
 
Engineering practice lab manual for electronics
Engineering practice lab manual for electronicsEngineering practice lab manual for electronics
Engineering practice lab manual for electronics
 
Exp 5 (1)5. Newton Raphson load flow analysis Matlab Software
Exp 5 (1)5.	Newton Raphson load flow analysis Matlab SoftwareExp 5 (1)5.	Newton Raphson load flow analysis Matlab Software
Exp 5 (1)5. Newton Raphson load flow analysis Matlab Software
 
Circuit Analysis Lab
Circuit Analysis LabCircuit Analysis Lab
Circuit Analysis Lab
 
Matlab simpowersystem
Matlab simpowersystemMatlab simpowersystem
Matlab simpowersystem
 
Ee 444 electrical drives be(tx) 2012
Ee 444 electrical drives be(tx) 2012Ee 444 electrical drives be(tx) 2012
Ee 444 electrical drives be(tx) 2012
 
EC 2 lab manual with circulits
EC 2 lab manual with circulitsEC 2 lab manual with circulits
EC 2 lab manual with circulits
 
Lab 02 Resistor color coding and ohms law
Lab 02   Resistor color coding and ohms lawLab 02   Resistor color coding and ohms law
Lab 02 Resistor color coding and ohms law
 
MATLAB programs Power System Simulation lab (Electrical Engineer)
MATLAB programs Power System Simulation  lab (Electrical Engineer)MATLAB programs Power System Simulation  lab (Electrical Engineer)
MATLAB programs Power System Simulation lab (Electrical Engineer)
 

Similar to 269010454 electrical-machines-lab-manual-for-petrochemaical

Similar to 269010454 electrical-machines-lab-manual-for-petrochemaical (20)

Electrical machines-lab-i-ee0209
Electrical machines-lab-i-ee0209Electrical machines-lab-i-ee0209
Electrical machines-lab-i-ee0209
 
Electrical machine lab
Electrical machine labElectrical machine lab
Electrical machine lab
 
Ped lab 2017 reg manual
Ped lab 2017 reg manualPed lab 2017 reg manual
Ped lab 2017 reg manual
 
Control_System_Lab.pdf
Control_System_Lab.pdfControl_System_Lab.pdf
Control_System_Lab.pdf
 
Ee 791 drives lab maual
Ee 791 drives lab maualEe 791 drives lab maual
Ee 791 drives lab maual
 
E&e lab manual
E&e lab manualE&e lab manual
E&e lab manual
 
Power Electronics lab manual BE EEE
Power Electronics lab manual BE EEEPower Electronics lab manual BE EEE
Power Electronics lab manual BE EEE
 
Mech EE6365 EE lab_manual
Mech EE6365 EE lab_manualMech EE6365 EE lab_manual
Mech EE6365 EE lab_manual
 
59849684 ee-cs
59849684 ee-cs59849684 ee-cs
59849684 ee-cs
 
Ac machines-lab-manual
Ac machines-lab-manualAc machines-lab-manual
Ac machines-lab-manual
 
ee2259-lab-manual
 ee2259-lab-manual ee2259-lab-manual
ee2259-lab-manual
 
Ee2259 lab-manual
Ee2259 lab-manualEe2259 lab-manual
Ee2259 lab-manual
 
59948408 ee-2304-pe-lab-manual-final2011
59948408 ee-2304-pe-lab-manual-final201159948408 ee-2304-pe-lab-manual-final2011
59948408 ee-2304-pe-lab-manual-final2011
 
Em manual 1
Em manual 1Em manual 1
Em manual 1
 
Occ of dc generator
Occ of dc generatorOcc of dc generator
Occ of dc generator
 
DC MOTOR
DC MOTORDC MOTOR
DC MOTOR
 
53669836 brake-test-on-a-d
53669836 brake-test-on-a-d53669836 brake-test-on-a-d
53669836 brake-test-on-a-d
 
Power Electronics Lab Manual ME PED
Power Electronics Lab Manual ME PEDPower Electronics Lab Manual ME PED
Power Electronics Lab Manual ME PED
 
Iii eie ii sem pe lab manual(ee382)
Iii eie ii sem pe lab manual(ee382)Iii eie ii sem pe lab manual(ee382)
Iii eie ii sem pe lab manual(ee382)
 
Power converter lab manual by chaturvedula
Power converter lab manual by chaturvedulaPower converter lab manual by chaturvedula
Power converter lab manual by chaturvedula
 

Recently uploaded

Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Celine George
 
The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13Steve Thomason
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationnomboosow
 
URLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppURLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppCeline George
 
Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon AUnboundStockton
 
Separation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesSeparation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesFatimaKhan178732
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application ) Sakshi Ghasle
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptxVS Mahajan Coaching Centre
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformChameera Dedduwage
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docxPoojaSen20
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxmanuelaromero2013
 
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdfBASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdfSoniaTolstoy
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxSayali Powar
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxpboyjonauth
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxGaneshChakor2
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docxPoojaSen20
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactdawncurless
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 

Recently uploaded (20)

Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
 
The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communication
 
URLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppURLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website App
 
Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon A
 
Separation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesSeparation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and Actinides
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application )
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy Reform
 
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docx
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptx
 
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdfBASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptx
 
CARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptxCARE OF CHILD IN INCUBATOR..........pptx
CARE OF CHILD IN INCUBATOR..........pptx
 
9953330565 Low Rate Call Girls In Rohini Delhi NCR
9953330565 Low Rate Call Girls In Rohini  Delhi NCR9953330565 Low Rate Call Girls In Rohini  Delhi NCR
9953330565 Low Rate Call Girls In Rohini Delhi NCR
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docx
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impact
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 

269010454 electrical-machines-lab-manual-for-petrochemaical

  • 1. RVS COLLEGE OF ENGINEERING &TECHNOLOGY (Approved by AICTE and affiliated to Anna University- Chennai) Kumaran Kottam., Sulur, Coimbatore - 641402. DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES LABORATORY LAB MANUAL R2013 STUDENT NAME : ………………………………….. REGISTER NUMBER : ………………………………….. DEPARTMENT: …………………………………..
  • 2. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 1 EI6411 ELECTRICAL MACHINES LABORATORY L T P C 0 0 3 2 OBJECTIVE: To impart hands on experience in verification of circuit laws and theorems, measurement of circuit parameters, study of circuit characteristics and simulation of time response. To expose the students to the basic operation of electrical machines and help them to develop experimental skills. LIST OF EXPERIMENTS. 1. Open circuit characteristics of D.C. shunt generator. 2. Load characteristics of D.C. shunt generator. 3. Load test on D.C. Shunt Motor. 4. Load test on D.C. Series Motor. 5. Swinburne’s test 6. Speed control of D.C. Shunt Motor. 7. Load test on Single Phase Transformer 8. Open circuit and Short circuit tests on Single Phase Transformer (Determination of equivalent circuit parameters). 9. Load test on Single Phase Induction Motor. 10. No load and blocked rotor tests on Three Phase Induction Motor (Determination of equivalent circuit parameters) 11. Load test on Three Phase Induction Motor. 12. Study of Starters TOTAL: 45 PERIODS OUTCOME: Ability to understand and analyze Instrumentation systems and their applications to various industries.
  • 3. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 2 CYCLE I CYCLE II
  • 4. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 3 SUMMARY OF EXPERIMENTS (Fill in the order by which done) Ex.No. Date Experiment Name Page No. Mark Staff Signature 1 2 3 4 5 6 7 8 9 10 11 12 Average
  • 5. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 4 CIRCUIT DIAGRAM FOR OPEN CIRCUIT ON SEPERATELY EXCITED DC GENERATOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 6. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 5 OPEN CIRCUIT TEST CHARACTERISTIC OF SEPARATELY EXCITED DC GENERATOR AIM: To conduct the open circuit test on a given separately excited dc generator and draw the characteristic curves. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1. Voltmeter MC (0-300)V 1 2. Ammeter MC (0-2) A 1 3. Rheostat Wire Wound 400 Ω / 1.1 A 1 4. Rheostat Double element 350 Ω / 2A 1 5. Tachometer Digital - 1 6. Connecting Wires - - As Req. FUSE RATING:  110-125% of rated current (full load current). PRECAUTION:  The motor field rheostat should be kept at minimum resistance position.  The generator field rheostat should be kept at maximum resistance position. FORMULAE USED: 1. Generated voltage Eg = VL + IaRa in Volts. Where, VL – Load voltage in Volts. Ia - Armature current in Amps. Ra - Armature resistance in Ohms.
  • 7. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 6 CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE TABLE 1: OPEN CIRCUIT TEST S. No Field current (If) Amps Open Circuit Voltage (Eo) Volts
  • 8. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 7 PROCEDURE: OPEN CIRCUIT TEST: 1. Note down the nameplate details of motor. 2. Connections are made as per the circuit diagram shown in diagram. 3. Initially SPST Switch is kept open. 4. Supply is given by closing the DPST Switch in the motor side. 5. Using the DC three point starter, start the motor. 6. The field rheostat of motor is adjusted to run the motor at rated speed. 7. Emf generated due to residual magnetism in the generator is noted along with the zero value field current. 8. Then, the SPST Switch is closed. Increase the field current in steps of 0.1 Amps by varying the resistance of the generator field and note down the corresponding open circuit voltages in Table (1). TO FIND ARMATURE RESISTANCE: 1. Connections are made as per the circuit diagram shown in diagram. 2. Supply is given by closing the DPST Switch and increase the load step by step. 3. Enter the corresponding ammeter and voltmeter readings in Table (2).
  • 9. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 8 TABLE 2: TO FIND ARMATURE RESISTANCE S. No. Current Ia (Amps) Voltage V (Volts) Ra=V/Ia ( ) Average value of R a=  MODEL GRAPH: MODEL CALCULATION:
  • 10. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 9 RESULT: VIVA QUESTIONS: 1. What is the function of carbon brush used in D.C generator? 2. What is meant by self-excited and separately excited dc generator? 3. What is the basic difference between dc generator and dc motor 4. Write down the emf equation of dc generator. Give the meaning of each symbol. 5. What is critical resistance of a DC shunt generator? 6. What are the conditions to be fulfilled for a shunt generator to build up Voltage? 7. What do you mean by residual flux in DC generator?
  • 11. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 10 CIRCUIT DIAGRAM FOR LOAD TEST ON SELF EXCITED DC SHUNT GENERATOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 12. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 11 LOAD TEST ON SELF EXCITED DC SHUNT GENERATOR AIM: To conduct the load test on a given self-excited dc shunt generator and draw the characteristic curves. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1. Voltmeter MC (0-300)V 1 2. Ammeter MC (0-10) A (0-2) A 1 1 3. Rheostat Wire Wound 400 Ω / 1.1 A 360 Ω / 2 A Each 1 4. Tachometer Digital - 1 5. Connecting Wires - - As Req. 6 Loading Rheostat Wire Wound - 1 FUSE RATING:  110-125% of rated current (full load current). PRECAUTIONS: 1. All connections should be perfectly tight and no loose wire should lie on the work table. 2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its maximum resistance position. 3. There should be no load on the motor at the time of starting. 4. At the time of starting, the field circuit rheostat is in minimum resistance position. 5. Hold the tachometer with both hands steady and in line with the motor shaft so that it reads correctly. FORMULAE USED: 1. Generated voltage (Eg) = VL + Ia Ra in Volts. Where, VL- Load voltage in Volts. Ia- Armature current in Amps & Ra- Armature resistance in Ohms.
  • 13. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 12 CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE TABLE 1: LOAD TEST S.No IL Amps If Amps Ia= IL- If Amps Terminal Voltage (VL) Volts Ia Ra Volts E g =VL + IaRa Volts
  • 14. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 13 PROCEDURE: LOAD TEST: 1. Note down the nameplate details of motor. 2. Connections are made as per the circuit diagram shown diagram. 3. Supply is given by closing the DPST Switch in the motor side. 4. Using the DC three point starter, start the motor. 5. The field rheostat of motor is adjusted to run the motor at rated speed. 6. The generator field rheostat is adjusted for the rated voltage. 7. The DPST switch in the generator side is closed. Increase the resistive load in steps of 2 Amps and note down the corresponding load current and terminal voltage values in Table (1). 8. Then the resistive load is gradually decreased and the DPST Switch on the generator side is open. Then the supply is switched off. 9. The generated voltage Eg is calculated by using the formulae as mentioned above and enter the values in the Table (1). TO FIND ARMATURE RESISTANCE: 1. Connections are made as per the circuit diagram shown in diagram. 2. Supply is given by closing the DPST switch and increases the load step by step. 3. Enter the corresponding ammeter and voltmeter readings in Table (2).
  • 15. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 14 TABLE 2: TO FIND ARMATURE RESISTANCE. S. No. Current Ia (Amps) Voltage V (Volts) Ra=V/Ia ( ) Average value of R a=  MODEL GRAPH: MODEL CALCULATION:
  • 16. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 15 RESULT: VIVA QUESTIONS: 1. State the various types of DC generators. 2. List the main parts of DC machine. 3. State the applications of various types of DC generators. 4. What is residual voltage? 5. Difference between self-excited and separately excited of DC generator.
  • 17. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 16 CIRCUIT DIAGRAM FOR LOAD TEST ON D.C SHUNT MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 18. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 17 LOAD TEST ON DC SHUNT MOTOR AIM: To conduct the load test on DC shunt motor and draw the characteristic curves. APPARATUS REQUIRED: S. No APPARATUS TYPE RANGE QUANTITY 1 Ammeter MC (0-20) A 1 2 Voltmeter MC (0-300) V 1 3 Tachometer Digital - 1 4 Rheostat Wire Wound wound 400 Ω/ 1.1 A 1 5 Connecting Wires - - As Req. FUSE RATING:  110-125% of rated current (full load current). PRECAUTIONS: 1. All connections should be perfectly tight and no loose wire should lie on the work table. 2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its maximum resistance position. 3. There should be no load on the motor at the time of starting. 4. At the time of starting, the field circuit rheostat is in minimum resistance position. 5. Hold the tachometer with both hands steady and in line with the motor shaft so that it reads correctly. FORMULAE USED: 1. Torque T = (S1~S2) × (R) × 9.81 in N-m. Where, R- Radius of the Brake drum in m. t- Thickness of the Belt in m. S1, S2- Spring balance reading in Kg.
  • 19. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 18 TABULATION: Radius of the brake drum: S. No Load Current (IL) Amps Load Voltage ( VL ) Volts Input Power ( Pi ) Watts Speed ( N ) rpm Spring Balance Reading (Kg) Torque (T) N-m Input Power (Pin) Watts Output Power (PO) Watts Efficiency ( η ) % S1 S2 S1~S2
  • 20. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 19 2. Input power = VL × IL in Watts. Where, VL - Load Voltage in Volts. IL -Load current in Amps. 3. Output power = 2πNT/60 in Watts. Where, N- Speed of the armature in rpm. T- Torque in N-m. 4. Percentage of Efficiency = (Output power/Input power) × 100. PROCEDURE: 1. Connections are given as per the circuit diagram. 2. Using the three-point starter the motor is started to run at the rated speed by adjusting the field rheostat if necessary. 3. The meter readings are noted at no load condition. 4. By using the Brake drum with spring balance arrangement the motor is loaded and the corresponding readings are noted up to the rated current. 5. After the observation of all the readings the load is released gradually. 6. Load is gradually decreased and field rheostat is brought to the minimum resistance position and the supply is switched off.
  • 21. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 20 MODEL GRAPH: Electrical Characteristics Mechanical Characteristics MODEL CALCULATION:
  • 22. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 21 RESULT: VIVA QUESTION: 1. How do you load the motor in this experiment? 2. What was the assumption made in calculations? 3. What is the condition for maximum torque of a D.C. shunt motor? 4. Why is the starter necessary? 5. What is the power factor of the load used?
  • 23. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 22 CIRCUIT DIAGRAM FOR LOAD TEST ON D.C. SERIES MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 24. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 23 LOAD TEST ON D.C. SERIES MOTOR AIM: To conduct load test on DC series motor and determine the load characteristics. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1. Voltmeter MC (0-300V) 1 2. Ammeter MC (0-20A) 1 3. Tachometer Digital - 1 4. Connecting wires - - As Req. PRECAUTIONS:  The series motor should be started with some minimum load.  Water should be poured in the hollow portion of brake drum.  Motor should be stopped with some minimum load.  After shut down, the load should be fully released, so as to make the drum free of cool. FORMULAE USED: 1. Torque applied on the motor, T = (S1~S2) x r x 9.81 Nm. 2. Input Power (Pi) = VL x IL Watts. Output, P0 = (2πNT)/60 Watts. 3. % Efficiency, η = (Po/Pi) x 100. Where, Circumference of the brake drum, 2 πr = ---------- m2 Radius of the brake drum, r = ---------- m S1&S2 spring balance readings in kg.
  • 25. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 24 TABULATION: Sl. No Line voltage VL Volts Line current IL Amps Speed N (rpm) Spring balance reading Torque T (N.m) Output Power P0 Watts Input Power Pi Watts % Efficiency η S1 Kg S2 Kg 1 2 3 4 5
  • 26. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 25 PROCEDURE: 1. Connections are made as per the circuit diagram. 2. Supply is given by closing DPSTS. 3. Start the motor using the starter. 4. Note down the readings for varying load conditions and plot the graph. MODEL CALCULATION: RESULT: VIVA QUESTIONS: 1. Why the series motor is started with some minimum load? 2. What are the applications of D.C. series motor? 3. Why series motors are used for traction purpose? 4. While running, if series field winding is opened what happens?
  • 27. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 26 CIRCUIT DIAGRAM FOR SWINBURN’S TEST FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 28. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 27 SWINBURNE’S TEST AIM: To predetermine the efficiency of a given dc shunt machine when working as a motor as well as generator by Swinburne’s test and also draw the characteristic curves. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1. Voltmeter MC ( 0-300 ) V ( 0-50 ) V 1 1 2. Ammeter MC (0-5) A (0-2) A 1 1 3. Rheostat Wire Wound 400 Ω / 1.1 A 1 4 Loading Rheostat Wire Wound 50 Ω / 5 A 1 5. Tachometer Digital - 1 6. Connecting Wires - - As Req FUSE RATING:  110-125% of rated current (full load current). PRECAUTIONS: 1. All connections should be perfectly tight and no loose wire should lie on the work table. 2. Before switching ON the dc supply, ensure that the starter’s moving arm is at its maximum resistance position. 3. There should be no load on the motor at the time of starting. 4. At the time of starting, the field circuit rheostat is in minimum resistance position. 5. Hold the tachometer with both hands steady and in line with the motor shaft so that it reads correctly.
  • 29. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 28 CIRCUIT DIAGRAM FOR ARMATURE RESISTANCE TABLE 1: TO FIND CONSTANT LOSSES TABLE 2: TO FIND ARMATURE RESISTANCE ‘R a’ S.NO INPUT SUPPLY VOLTAGE (Volts) NO LOAD CURRENT I 0 (Amps) FIELD CURRENT I f (Amps) ARMATURE CURRENT Iao = I 0 - I f (Amps) CONSTANT LOSSES Wo = VI 0 – I ao 2 R a (Watts) S.NO CURRENT Ia ( Amps ) VOLTAGE V ( Volts ) ARMATURE RESISTANCE Rdc = V / I a (Ohms) 1. 2. 3. 4. 5. Average value of Ra =
  • 30. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 29 FORMULAE USED: 1. Armature Current on no load, I ao = I0 – I f 2. Constant losses, W c = VI 0 – I ao 2 Ra 3. Armature resistance, Ra = V / I a MOTOR ACTION: 1. Load current = IL 2. Armature current , I a = IL – I f 3. Armature Copper loss = I a 2 Ra 4. Total losses = Wc + I a 2 Ra 5. Input = V I 6. Output = Input – Losses 7. Efficiency,  = (Output / Input) x 100 GENERATOR ACTION: 1. Armature Current I a = IL + I f 2. Armature Copper loss = I a 2 R a 3. Total losses = W c + I a 2 R a 4. Output = V I 5. Input = Output + Losses 6. Efficiency,  = (Output / Input) x 100 PROCEDURE: NO LOAD TEST: 1. Note the name plate details of the machine. 2. The connections are made as per circuit diagram. 3. Close the DPST switch. 4. Start the motor by using three-point starter. 5. Adjust the speed to rated speed by increasing field circuit resistance (Field rheostat). 6. Enter the input voltage, No load current and field current in Table (1). TO FIND Ra: 1. The connections are made as per circuit diagram shown in diagram. 2. Close the DPST switch and increase the load step by step. 3. Enter the corresponding ammeter and voltmeter readings in Table (2).
  • 31. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 30 TABLE (3): CALCULATION OF EFFICIENCY AS A MOTOR: Constant Loss: Calculated value from Table (1) TABLE (4): CALCULATION OF EFFICIENCY AS A GENERATOR: S. No Load Current I (Amps) Armature Current Ia = I - I f (Amps) Armature Copper loss = I a 2 R a (Watts) Total Losses = Wo+ I a 2 R a (Watts) Input V I (Watts) Output = Input – losses (Watts) Efficiency =(output/ input)x100 (Percentage) 1. ¼ th of rated value 2. ½ th of rated value 3. ¾ th of rated value 4. Rated value S. No Load Current I (Amps) Armature Current Ia = I + I f (Amps) Armature Copper loss = I a 2 R a (Watts) Total Losses = Wo+ I a 2 R a (Watts) Output V I (Watts) Input = Output + Losses (Watts) Efficiency =(output/ Input)x100 (Percentage) 1. ¼ th of rated value 2. ½ th of rated value 3. ¾ th of rated value 4. Rated value
  • 32. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 31 MODEL GRAPH: MODEL CALCULATION:
  • 33. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 32
  • 34. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 33 RESULT: VIVA QUESTION: 1. What is the function of no-volt release coil in 3point starters? 2. How to change the direction of rotation of d.c motor? 3. Swinburne‘s test is also called? 4. List the various losses in d.c machine. 5. Name the various methods of testing the d.c machine.
  • 35. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 34 CIRCUIT DIAGRAM FOR SPEED CONTROL OF DC SHUNT MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 36. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 35 SPEED CONTROL OF DC SHUNT MOTOR AIM: To control the speed of the given DC shunt motor by field and armature control methods and also to draw their characteristics curves. APPARATUS REQUIRED: S. No APPARATUS TYPE RANGE QUANTITY 1 Ammeter MC (0-2) A 1 2 Voltmeter MC (0-300) V 1 3 Tachometer Digital - 1 4 Rheostat Wire Wound 400 Ω/ 1.1 A 1 5 Rheostat Wire wound 50 Ω/ 5 A 1 6 Connecting Wires - -- As Req FUSE RATING:  110-125% of rated current (full load current). PRECAUTIONS:  All connections should be perfectly tight and no loose wire should lie on the work table.  There should be no load on the motor at the time of starting.  At the time of starting, the field circuit rheostat is in minimum resistance position and armature rheostat is in maximum position.  Hold the tachometer with both hands steady and in line with the motor shaft so that it reads correctly.
  • 37. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 36 TABLE 1: FIELD CONTROL METHOD. Rated Speed: TABLE 2: ARMATURE CONTROL METHOD Rated Speed: S.NO. Armature Voltage (Va)= Speed (N) (Rpm) Field Current (If) (Amps) S.NO Field Current(If)= Speed (N) (Rpm) Armature Voltage (Va) (Volts)
  • 38. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 37 PROCEDURE: Field current (or) flux control method: 1. Note down the name plate details of the motor. 2. Connections are made as per circuit diagram. 3. The motor run at rated speed by adjusting the armature and field rheostat. 4. Keep the armature voltage constant at rated value. 5. Increase the speed in steps of 50 rpm above the rated speed using field rheostat and note down the corresponding field current values in Table (1). Armature (or) voltage control method: 1. Note down the name plate details of the motor. 2. Connections are made as per circuit diagram. 3. The motor run at rated speed by adjusting the armature and field rheostat. 4. Keep the field current constant at rated speed. 5. Decrease the speed in steps of 50 rpm below the rated speed using armature rheostat and note down the corresponding field current values in Table (2).
  • 39. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 38 MODEL GRAPH: Armature Control Method Field Control Method MODEL CALCULATION:
  • 40. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 39 RESULT: VIVA QUESTION: 1. What are the limitations of armature voltage control and field current control methods? 2. Why both rheostats are kept at minimum resistance position in the starting condition? 3. What is starter? Why is it required? 4. What are the applications of dc shunt motor? 5. Why brushes are made from carbon? 6. Why is thin conductor used for field winding? & thick conductor for armature winding?
  • 41. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 40 CIRCUIT DIAGRAM FOR LOAD TEST ON SINGLE PHASE TRANSFORMER FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 42. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 41 LOAD TEST ON SINGLE PHASE TRANSFORMER AIM: To conduct the load test on a given single phase transformer and draw its performance curves. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1 Ammeter MI (0-5)A 1 (0-10)A 1 2 Voltmeter MI (0-300)V 1 (0-150)V 1 3 Wattmeter UPF 300V,5A 1 4 1φ auto transformer 230/(0-270)V 1 5 1φ step down transformer 230/110V,1KVA 1 6 Loading Rheostat Wire Wound 1 7 Tachometer Digital 1 8 Connecting wires - - As required 9 DPST - - 1 FUSE RATING:  Primary Current = KVA Rating of the Transformer / Primary Voltage.  Secondary Current = KVA Rating of the Transformer / Secondary Voltage.  110-125% of Primary current (fuse rating for primary side).  110-125% of Secondary current (fuse rating for secondary side). PRECAUTIONS:  At the time of starting, the DPST switch on secondary side should be kept in open condition.  At the time of starting, there should be no load on the loading rheostat.
  • 43. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 42 Table: Load Test on Single Phase Transformer. Multiplication Factor =
  • 44. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 43 FORMULAE: 1. Output power = Vs x Is x CosΦ in Watts. Where, Vs – Secondary voltage in volts. Is – secondary current in amps. Cos Φ - power factor. 2. Input Power = Wattmeter reading in Watts. 3. Efficiency = (output power/Input power) X 100 % 4. Voltage Regulation = [(V no load - V load) / (V load)] X100 % Where, V no load – no load voltage in volts. V load – load voltage in volts. PROCEDURE: 1. Connections are given as per the circuit diagram. 2. The SPST Switch on the Primary side is closed and the DPST Switch on the Secondary side is opened. 3. The Autotransformer is adjusted to energize the transformer with rated Primary Voltage. 4. The Volt meters and Ammeters Readings are noted and tabulated at No load condition. 5. The DPST switch on the secondary side is closed. 6. The transformer is loaded up to 130% of the Rated Load, corresponding Ammeters, Voltmeters and Wattmeter readings are noted and tabulated. 7. After the observation of all the readings the load is released gradually to its initial position. 8. The Autotransformer is brought to its initial position. 9. The Supply is switched off.
  • 45. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 44 MODEL GRAPH: MODEL CALCULATION:
  • 46. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 45 RESULT: VIVA QUESTIONS:
  • 47. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 46 CIRCUIT DIAGRAM FOR OPEN CIRCUIT TEST ON SINGLE PHASE TRANSFORMER Tabulation for OC test on Single phase transformer Multiplication Factor =
  • 48. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 47 OPEN CIRCUIT TEST AND SHORT CIRCUIT TEST ON SINGLE PHASE TRANSFORMER AIM: To Predetermine the Efficiency and Regulation on a given single phase transformer by conducting the Open Circuit test and Short Circuit test and also draw its Equivalent circuit. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1 Ammeter MI (0-1)A, (0-5A) (0-10A) Each 1 2 Voltmeter MI (0-300)V 1 (0-150)V 1 3 Wattmeter LPF UPF 150V,1A 150V,5A Each 1 4 1φ auto transformer 230/(0-270)V 1 4 1φ Taping transformer 230/110V,1KVA 1 5 Tachometer Digital - 1 6 Connecting wires - - As required FUSE RATING:  Primary Current = KVA Rating of the Transformer / Primary Voltage.  Secondary Current = KVA Rating of the Transformer / Secondary Voltage.  110-125% of Primary current (fuse rating for primary side).  110-125% of Secondary current (fuse rating for secondary side). PRECAUTIONS:  At the time of starting, the auto transformer should be in the minimum voltage position.  For O.C test, the HV side of the transformer is in open circuit condition.  For S.C test, the LV side of the transformer is short circuited.
  • 49. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 48 CIRCUIT DIAGRAM FOR SHORT CIRCUIT TEST ON SINGLE PHASE TRANSFORMER Tabulation for SC test on Single phase transformer Multiplication Factor =
  • 50. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 49 FORMULAE USED: O.C Test: 1. No load Power factor, Cos Φo = [ Woc / ( Voc x I oc ) ] Where, Woc – No load losses. Voc – No load voltage. I oc – No load current. 2. Magnetizing component, Im = I oc x Sin Φo 3. Working component, Iw = I oc x Cos Φo 4. No load resistance, R 0 = V oc / Iw in ohms 5. No load reactance, X 0 = V oc / Im in ohms S.C Test. 1. Primary winding resistance, R1 = Wsc / Isc 2 in ohms Where, Wsc - Short circuit power in Watts Isc - Short circuit current in Amps 2. Primary winding impedance, Z1 = Vsc / Isc in ohms where, V sc = Short circuit voltage in Volts 3. Primary winding reactance, X1 = Z1 2 - R1 2 in ohms 4. Secondary winding resistance, R 2 = W sc / I sc 2 in ohms 5. Secondary winding impedance , Z 2 = V sc / Isc in ohms 6. Secondary winding reactance , X2 = Z 2 2 – R2 2 in ohms 7. Transformation ratio ( K ) = V 2 / V 1 8. Equivalent secondary resistance referred to primary side, R2 ‘ = R2 / K 2 in ohms. 9. Equivalent secondary reactance referred to primary side, X2 ‘ = X2 / K 2 in ohms.
  • 51. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 50 TO CALCULATE THE EFFICIENCY: Iron loss (Wi): Calculated from Table (1) Short Circuit loss (Wsc): Calculated from Table (2) S.NO LOAD FRACTION X IRON LOSS Wi (Watts) COPPER LOSS X2 WSC (Watts) TOTAL LOSS W (Watts) OUTPUT POWER PO (Watts) INPUT POWER Pi (Watts) EFFICIENCY η (%) UPF PF=0.8 UPF PF=0.8 UPF PF=0.8 1 0.25 2 0.5 3 0.75 4 1.00 5 1.25
  • 52. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 51 EFFICIENCY: 1. Iron loss, wi = woc in Watts. Where, Woc - No load loss. 2. Copper loss, Wc - x2 WSC in Watts. Where, x - Fraction of load. WSC - Short circuit losses. 3. Total loss, W = Wi + Wc in Watts. 4. Output power, Po = x X kVA X Cos Φ 5. Where, Cos Φ – power factor. Cos Φ= 1 for UPF. Cos Φ= 0.8 for LPF. 6. Input power, Pi = Po+ W in Watts. 7. Efficiency, η = (Po / Pi) X 100 % REGULATION: 1. Percentage Regulation = [x Isc / VOC ( R01 Cos Φ ± X01 Sin Φ ) ] x 100 % + Lagging Leading 2. Total resistance as referred to primary side, R01= R1 + R2 ‘in ohms. 3. Total reactance as referred to primary side, X01 = X1+ X2 ‘in ohms.
  • 53. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 52 Resultant Tabulation to find out the Efficiency: Core (Or) Iron Loss = A Rating of Transformer = Rated Short Circuit Current (ISC) = Short Circuit Power (WSC) = Resultant Tabulation to find out the Regulation: POWERFACTOR COS Φ 125% LOAD, X = 1.25 100% LOAD, X = 1 75% LOAD, X = 0.75 LAG LEAD LAG LEAD LAG LEAD 0.2 0.4 0.6 0.8 1
  • 54. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 53 PROCEDURE: OPEN CIRCUIT TEST: 1. Connections are given as per the circuit diagram. 2. The SPST Switch on the Primary side is closed. 3. The Autotransformer is adjusted to Energize the transformer with rated Primary Voltage on the LV side 4. The Volt meter, Watt meter and Ammeter Readings are noted at No load condition 5. The Autotransformer is brought to its initial position 6. The Supply is switched off. SHORT CIRCUIT TEST: 1. Connections are given as per the circuit diagram. 2. The SPST Switch on the Primary side is closed 3. The Autotransformer is adjusted to energize the transformer with rated Primary Current on the HV side. 4. The Voltmeter, Wattmeter and Ammeter Readings are noted down at short circuit condition. 5. The Autotransformer is brought to its initial position 6. The Supply is switched off.
  • 55. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 54 EQUIVALENT CIRCUIT FOR SINGLE PHASE TRANSFORMER MODEL GRAPH: MODEL CALCULATION:
  • 56. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 55 RESULT: VIVA QUESTIONS:
  • 57. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 56 CIRCUIT DIAGRAM FOR LOAD TEST ON SINGLE PHASE INDUCTION MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 58. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 57 LOAD TEST ON SINGLE PHASE INDUCTION MOTOR AIM: To determine the performance characteristic of a given single phase capacitor start induction motor by conducting load test. APPARATUS REQUIRED: FUSE RATING:  Fuse rating = 125% of rated current. PRECAUTION:  Before switching on the supply the single phase auto transformer is kept in minimum position.  Initially these should be on no load while starting the motor. FORMULA USED: 1. Torque, T = (S1~S2)*9.81*R N.m. 2. Output power = 2π NT/60*W 3. Effecting (η%) = 0/P Power/I/p Power*100 4. Slip (%S) = NS – N/NS*100 5. Power factor = Cos φ=W/VI PROCEDURE: 1. Connections are given as per the circuit diagram. 2. Switch on the supply at no load condition. 3. Apply the rated voltage to the motor using the single phase auto transformer and note down the readings at ammeter and wattmeter. 4. Vary the load in suitable steps and note down all the meter readings till full load condition. SL. NO APPARATUS RANGE TYPE QUANTITY 1 Voltmeter (0-300) V MI 1 2 Ammeter (0-20) A MI 1 3 Wattmeter 300 V, 20 A UPF 1 4 Tachometer - Digital 1 5 1φ auto transformer 230V/0-270V 1 6 Connecting wires - - As Req.
  • 59. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 58 TABLULATION: M.F = MODEL CALCULATION: Sl.No. VL (V) IL (A) Speed(N) (Rpm) S1 (Kg) S2 (Kg) S1 ̃~ S2 (Kg) Torque (N-m) Wattmeter Reading Output Power (W) Efficiency η% PF=cosΦ %Slip Obs. (W) Actual (W)
  • 60. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 59
  • 61. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 60 MODEL GRAPH: ELECTRICAL CHARACTERISTICS: MECHANICAL CHARACTERISTICS:
  • 62. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 61 RESULT: VIVA QUESTIONS:
  • 63. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 62 CIRCUIT DIAGRAM FOR NO LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 64. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 63 EQUIVALENT CIRCUIT OF THREE PHASE SQUIRREL CAGE INDUCTION MOTOR AIM: To conduct a No Load test and Blocked Rotor test on three phase squirrel cage induction motor and to draw the equivalent circuit. APPARATUS REQUIRED: S.NO APPARATUS TYPE RANGE QUANTITY 1 Ammeter MI (0-5A), (0-10A) Each 1 2 Voltmeter MI (0-600)V 1 3 Wattmeter UPF,LPF 600V,5A 150V,10A Each 1 4 3φ auto transformer 415/(0-470)V 1 5 Tachometer Digital - 1 6 Connecting wires - - As required FUSE RATING:  No Load: 10 % of rated current (Full load current).  Load: 110-125 % of rated current (Full load current). PRECAUTION:  The autotransformer should be kept at minimum voltage position.
  • 65. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 64 CIRCUIT DIAGRAM FOR BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR (Equivalent circuit)
  • 66. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 65 FORMULAE USED: OC TEST: 1. No load power factor (Cos φ 0) = P0/V0I0 V0 - No load voltage per phase in volts. I0 - No load current per phase in amps. P0 - No load power per phase in watts. 2. Working component current (Iw) = I0 (ph) X Cos φ 0 3. Magnetizing current (Im) = I0 (ph) X Sin φ 0 4. No load resistance (R0) =V0/I0 (ph) Cos φ 0 in W. 5. No load reactance (X0) = V0/I0 (ph) Sin φ 0 in W. SC TEST: 1. Motor equivalent Impedance referred to stator (Zsc(ph)) = Vsc(ph) / Isc(ph) in Ω. 2. Motor equivalent Resistance referred to stator (Rsc(ph)) = Psc(ph) / I2 sc(ph) in Ω. 3. Motor equivalent Reactance referred to stator (Xsc(ph)) = √(Z sc(ph)2 - Rsc(ph)2 ) in Ω. 4. Rotor Resistance referred to stator (R2’(ph)) = Rsc(ph) – R1 in Ω. 5. Rotor Reactance referred to stator (X2’(ph)) = Xsc(ph) / 2 = X1 in Ω. Where, R1 - stator resistance per phase. X1 – stator reactance per chapter. R1 = R(ac) =1.6 x R(dc). 6. Equivalent load resistance (RL’) = R2’ (1/s – 1) in Ω. Where, Slip (S) = (Ns-Nr) / Ns. Ns – Synchronous speed in rpm. Nr – Rotor speed in rpm.
  • 67. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 66 TABULATION FOR NO LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR Speed of the Induction motor: Type of the Stator connection: Multiplication Factor: TABULATION FOR BLOCKED ROTOR TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR Type of the Stator connection: Multiplication Factor:
  • 68. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 67 PROCEDURE: 1. Connections are given as per the circuit diagram. 2. For No-Load or open circuit test by adjusting autotransformer, apply rated voltage and Note down the voltmeter, ammeter and wattmeter readings. In this test rotor is free to rotate. 3. For short circuit or blocked rotor test by adjusting autotransformer, apply rated current and note down the voltmeter ,ammeter and wattmeter readings. In this test rotor is blocked. 4. After that make the connection to measure the stator resistance as per the circuit diagram. 5. By adding the load through the loading rheostat note down the ammeter, voltmeter reading for various values of load.
  • 69. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 68 EQUIVALENT CIRCUIT FOR THREE PHASE SQUIRREL CAGE INDUCTION MOTOR MODEL CALCULATION:
  • 70. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 69 RESULT: VIVAQUESTION:
  • 71. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 70 CIRCUIT DIAGRAM FOR LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR FUSE RATING 125% of rated current. NAME PLATE DETAILS
  • 72. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 71 LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR AIM: To conduct a load test on a three phase squirrel cage induction motor and to draw the performance characteristic curves. APPARATUS REQUIRED: FUSE RATING:  110-125% of rated current (Full load current). PRECAUTIONS:  There should be no load on the motor at the time of starting. FORMULAE USED: 1. Torque = (S1-S2) (R+t/2) x 9.81 N-m Where, S1, S2 – spring balance readings in Kg. R - Radius of brake drum in m. t - Thickness of belt in m. Output Power = 2 PNT/60 watts. N- Rotor speed in rpm. T- Torque in N-m. 2. Input Power = (W1+W2) Watts. W1, W2 – Wattmeter readings in Watts. 3. Percentage of Efficiency = (Output Power/ Input Power) x 100%. S.NO APPARATUS TYPE RANGE QUANTITY 1 Ammeter MI (0-5/10)A 1 2 Voltmeter MI (0-600)V 1 3 Wattmeter UPF 600V,5/10A 2 4 Tachometer Digital 1 5 Connecting wires - - As required
  • 73. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 72 TABULATION FOR LOAD TEST ON THREE PHASE SQUIRREL CAGE INDUCTION MOTOR. Multiplication Factor:
  • 74. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 73 4. Percentage of Slip = (NS-Nr)/Ns x 100% Ns-Synchronous speed in rpm. Nr-Rotor speed in rpm. 5. Power factor = (W1+W2)/ √ 3 VLIL. PROCEDURE: 1. Connections are given as per the circuit diagram. 2. The TPSTS is closed and the motor is started using On Line starter to run at rated speed. 3. At no load the speed, current, voltage and power are noted down. 4. By applying the load for various values of current the above-mentioned readings are noted. 5. The load is later released and the motor is switched off and the graph is drawn.
  • 75. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 74 MODEL GRAPHS: Mechanical Characteristics Electrical Characteristics MODEL CALCULATION:
  • 76. Lab Manual: Electrical Machines Laboratory (EI6411) Regulation 2013 75 RESULT: VIVA QUESTION: