The document contains architectural plans and drawings for proposed additions and alterations to an existing dwelling. It includes floor plans and elevations showing details of the proposed additions including a new patio, laundry area, and entertainment area. It also provides specifications for materials, roofing, drainage, and other construction details. Dimensions, technical notes, and requirements are included to guide the construction work in compliance with relevant standards and regulations.
This document contains an architectural plan for a multi-level building with various workshops, studios, and other facilities. It includes floor plans for the ground level, first floor, roof top, upper ground level, and second floor. Sections and elevations are provided with callouts for structural and material details. The document also lists relevant architects, engineers, and the client for the project.
BUILDING TECHNOLOGY 2: Project 2- Working Drawing- Construction DrawingAngeline KH
This document contains construction drawings for a proposed 5-storey film theatre building, including floor plans, sections, and elevations. Key features shown are a basement car park, ground floor retail spaces, and upper floors containing a theatre, cafe, studios, and roof garden. Construction details illustrate structural elements like concrete slabs, walls, and steel framing. Dimensions and technical specifications are provided to fully convey the building design for construction.
Installation instructions for stainless steel chimney liners, specifically the Fireflex model CB styles. Learn more at the Fireside Chimney Supply website.
This document provides construction details for various elements of a multi-level residential building, including:
- Minimum floor void depths for drainage of 705mm, 460mm, and 315mm for Blocks B, C, and D, respectively.
- Lower ground floor construction of beam and block with a U-value of 0.13 W/m2K.
- External wall construction for the lower ground floor with a U-value of 0.18 W/m2K.
- Part ground and first floor separating floor construction with an airborne sound insulation of minimum 45dB and impact sound insulation of 62dB.
- Pitched clay tiled roof construction to achieve a U-value of 0.
The document contains construction drawings and details for a multi-level building including floor plans, wall sections, and structural details. It includes floor elevation notes, material specifications, and technical details for concrete foundations, masonry walls, suspended ceilings, windows, roofing, and other building components. Dimensioned sections and details provide specifications for construction of walls, floors, windows, roofing, insulation, and other building elements.
The document contains construction specifications and details for a proposed office block including:
- Structural elements like concrete beams, brick walls, and foundations to be plastered and painted according to specifications.
- Finishes and materials for walls, floors, stairs, balustrades, shopfronts, and roofing.
- Fire protection, lighting, ventilation and accessibility notes to comply with building regulations.
- Schedules for areas, parking requirements, and notations for various construction aspects.
This document contains plans and specifications for a 6 bedroom house with 2 garages. It includes a ground floor plan, elevations, sections, roof plan, ceiling level plan, and site plan. The plans are drawn at scales of 1:200 and 1:500. Specifications cover foundations, floors, walls, ceilings, roof construction, windows/doors, drainage, and other details. The project is described as a house plan for a 6 room house with 2 single garages.
The document contains architectural plans and drawings for proposed additions and alterations to an existing dwelling. It includes floor plans and elevations showing details of the proposed additions including a new patio, laundry area, and entertainment area. It also provides specifications for materials, roofing, drainage, and other construction details. Dimensions, technical notes, and requirements are included to guide the construction work in compliance with relevant standards and regulations.
This document contains an architectural plan for a multi-level building with various workshops, studios, and other facilities. It includes floor plans for the ground level, first floor, roof top, upper ground level, and second floor. Sections and elevations are provided with callouts for structural and material details. The document also lists relevant architects, engineers, and the client for the project.
BUILDING TECHNOLOGY 2: Project 2- Working Drawing- Construction DrawingAngeline KH
This document contains construction drawings for a proposed 5-storey film theatre building, including floor plans, sections, and elevations. Key features shown are a basement car park, ground floor retail spaces, and upper floors containing a theatre, cafe, studios, and roof garden. Construction details illustrate structural elements like concrete slabs, walls, and steel framing. Dimensions and technical specifications are provided to fully convey the building design for construction.
Installation instructions for stainless steel chimney liners, specifically the Fireflex model CB styles. Learn more at the Fireside Chimney Supply website.
This document provides construction details for various elements of a multi-level residential building, including:
- Minimum floor void depths for drainage of 705mm, 460mm, and 315mm for Blocks B, C, and D, respectively.
- Lower ground floor construction of beam and block with a U-value of 0.13 W/m2K.
- External wall construction for the lower ground floor with a U-value of 0.18 W/m2K.
- Part ground and first floor separating floor construction with an airborne sound insulation of minimum 45dB and impact sound insulation of 62dB.
- Pitched clay tiled roof construction to achieve a U-value of 0.
The document contains construction drawings and details for a multi-level building including floor plans, wall sections, and structural details. It includes floor elevation notes, material specifications, and technical details for concrete foundations, masonry walls, suspended ceilings, windows, roofing, and other building components. Dimensioned sections and details provide specifications for construction of walls, floors, windows, roofing, insulation, and other building elements.
The document contains construction specifications and details for a proposed office block including:
- Structural elements like concrete beams, brick walls, and foundations to be plastered and painted according to specifications.
- Finishes and materials for walls, floors, stairs, balustrades, shopfronts, and roofing.
- Fire protection, lighting, ventilation and accessibility notes to comply with building regulations.
- Schedules for areas, parking requirements, and notations for various construction aspects.
This document contains plans and specifications for a 6 bedroom house with 2 garages. It includes a ground floor plan, elevations, sections, roof plan, ceiling level plan, and site plan. The plans are drawn at scales of 1:200 and 1:500. Specifications cover foundations, floors, walls, ceilings, roof construction, windows/doors, drainage, and other details. The project is described as a house plan for a 6 room house with 2 single garages.
This document contains detailed specifications and dimensions for barrier-free bathroom components and construction details. It lists materials like stainless steel towel dispensers, grab bars, and sinks to be installed. It also includes framing details showing wall stud and insulation layouts, as well as curtain wall system specifications with thermal breaks and factory sealed double glazing. Dimensioned details are provided for the corner column, entrance corner, and washroom layout to ensure accessibility code compliance.
India’s !st & only Hollywood benchmarked studio facilityarchana jhangiani
Introducing India’s first and only Hollywood benchmarked studio facility
Special Mentions:
“The newly built Reliance Media Works Studio... woah! Stunning! I've never seen such opulence and systems in a film studio..”- Referenced from Twitter handle of Mr. Amitabh Bachchan.
"After what I have seen here, there is a possibility of me coming back to make a movie here, after all"- Oliver Stone, as said to The Economic Times, India.
This document contains plans and elevations for proposed additions and alterations to an existing dwelling. It includes drawings showing the east, west, north and south elevations, as well as roof plans, sections and schedules. Dimensions are provided for new construction elements like a walk-in closet and en-suite bathroom. Material specifications and compliance with building regulations are noted.
This document provides construction specifications for a two-storey domestic extension project. It includes 3 key elements:
1) Ground floor construction will be an in-situ cast concrete slab on insulation and damp proof membrane. External walls will be cavity construction with brick outer skin, cavity insulation and block inner skin.
2) Windows and doors will be uPVC units meeting relevant thermal and structural standards. Internal partitions will be blockwork or timber stud walls.
3) The pitched roof will have rafters, insulation, and single-ply membrane. The dormer roof will have an optimized system with insulation and vapor control layer. Services and general works must comply with regulations.
Freelance project management case studies - residentialgrahamelanders
This document contains construction drawings for a proposed residential extension, including:
- Section and detail drawings showing proposed structures like the kitchen aperture support, eaves, substructure, and roof.
- Notes specifying materials and methods for elements like the external walls, windows, drainage, foundations, and more.
- The project aims to gain approval for a new two-story extension to an existing dwelling.
- Freelance project management services included producing the drawings, liaising with structural engineers, and conducting site inspections.
The document contains architectural plans and drawings for the Ice House Hotel project in Ballina, County Mayo, Ireland. It includes floor plans, elevations, and sections for the basement, lower ground, ground, and first floors of the existing building as well as schedules for doors, windows, and areas. Dimensions and technical details are provided for the building elements. The drawings are at scales between 1:100 and 1:1000 and were created by Mark Thornton for his BIM module as part of an architectural technology degree.
This document provides a summary of plans and specifications for a 6 room house with a garage. It includes a project description, list of drawings, general notes on compliance with building codes and dimensions. It also outlines specifications for foundations, floors, walls, ceilings, the roof construction, windows/doors, drainage and other details. The plans were drawn by Robert Ledwaba for client Sengatane Moletjie and include a site plan, elevations, sections and 3D views at a scale of 1:200.
The document provides details on pre-cast concrete panels used in the Whitefriar Rejuvenation Project, including a community centre and creche. The panels play a crucial role in providing insulation and thermal comfort. They act as the skin of the building but require a primary structure for support. In the design, the panels are tied to a cast in situ concrete post and beam structure using heavy duty steel fixings. The panels incorporate features like 120mm PIR insulation, concrete parapets, and are 330mm thick with a 150mm concrete core.
This document contains construction drawings and notes for a two-story home extension project. It includes scale drawings of floor plans and building sections with callouts for materials and construction details. Notes specify that existing foundation depths must be checked on site for possible underpinning. It also provides instructions to remove existing insulation and brick, install new studs and insulation, and ensure cavities are filled before the new floor is laid.
The document is a site plan and specifications for renovations and additions to a property. It includes demolishing some walls, adding new windows and doors, renovating bathrooms, constructing a new garage and boundary walls, and other interior renovations. Dimensions and materials are provided for the new construction. The total existing building area is 227.53 sqm and the new construction will increase this by 72.94 sqm, bringing the total coverage to 31.21% of the 1,197 sqm erf. Health and safety, contractor, and other legal notes are included at the bottom.
This document contains 4 proposed section elevations (A-A through D-D) and 1 proposed section knockout panel for a two-phase home extension project. Section A-A shows elevations for Phase 1 and 2 including a ventilated void, new roof construction details, and floor/ceiling heights. Section B-B shows elevations for Phase 2 including a garage, new roof, and floor/ceiling heights. Section C-C and D-D show elevations for Phase 1 including a stair/void details and new roof. Materials and a site plan are also specified.
The document is a builders drawing showing plans and elevations for a restaurant renovation project. It includes details like dimensions, materials, and notes on fire safety standards. Key information includes plans for the ground floor showing the layout of the main restaurant area, kitchen, toilets, and exterior seating. Notes provide requirements for fire resistance of walls and glazing, means of escape capacities, and toilet provisions to meet building standards.
This document contains a legend and sheet index for architectural drawings of a commercial building project. The legend defines different wall assemblies using materials like metal panels, insulation, steel studs, and CMU. The sheet index lists 9 drawings including site plans, floor plans, elevations, sections, wall details, and stair/elevator plans.
1. The document contains plans for 3 apartments in a new development called Hudson Close Apartments. It includes a ground floor plan showing the layout of the apartments, common areas, and details.
2. The plans show the layout of the individual apartments including bedrooms, bathrooms, kitchens, and living areas. Common areas on the ground floor include a hallway and stairwell.
3. Technical specifications are provided for the building materials and construction methods to be used, including the foundations, flooring, walls, roof, ventilation, and other details.
This document provides a landscape design plan for a residential property. It includes:
1) A site plan showing the proposed landscaping elements such as garden beds, lawn areas, a fire pit, seating, and trees.
2) Planting notes describing soil preparation, mulching, fertilizing, and maintenance requirements.
3) Details for hardscaping elements including paving materials, retaining walls, and irrigation.
4) A list of plant species to be used in the design.
The document provides details for the construction of a freezer including dimensions for walls, panels, supports, and other structural elements. Measurements are given for wall thicknesses, ceiling heights, panel spacings, and other construction specifications. Details are also shown for the roof support system, insulation, vapor barriers, flooring system, and door thresholds.
This document contains architectural drawings for a 3 storey residential building including floor plans, elevations, sections, details and 3D renderings. The drawings show the layout of each floor with room dimensions and labels. Elevations display the external appearance of the building. Sections cut through the building to show internal construction. Details provide closer views of specific building elements like doors, windows and construction assemblies. 3D perspectives and renders demonstrate the proposed design from different angles.
This Installation Guide shows how easy it is to install FloodBreak passive floodgates at vulnerable flood paths and provide permanent flood protection without the need for human intervention or power.
This document contains architectural plans for a proposed two-storey home extension including a ground floor addition of 34.66 square meters and first floor addition of 22.08 square meters. The plans show the layout of the existing house and proposed additions, including new windows, doors, rooflights, and structural elements. Construction details are provided for the foundations, walls, floors, roof, insulation, and materials. The project will update an existing house with a modernized layout and improved energy efficiency.
This document is an architectural design drawing for a proposed two-storey side extension with attached garage at an existing property. The drawing provides details of the proposed ground floor and first floor plans, including new windows, doors, walls and other structural elements. Dimensions and technical specifications are included to fully describe the proposed construction work.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
This document contains detailed specifications and dimensions for barrier-free bathroom components and construction details. It lists materials like stainless steel towel dispensers, grab bars, and sinks to be installed. It also includes framing details showing wall stud and insulation layouts, as well as curtain wall system specifications with thermal breaks and factory sealed double glazing. Dimensioned details are provided for the corner column, entrance corner, and washroom layout to ensure accessibility code compliance.
India’s !st & only Hollywood benchmarked studio facilityarchana jhangiani
Introducing India’s first and only Hollywood benchmarked studio facility
Special Mentions:
“The newly built Reliance Media Works Studio... woah! Stunning! I've never seen such opulence and systems in a film studio..”- Referenced from Twitter handle of Mr. Amitabh Bachchan.
"After what I have seen here, there is a possibility of me coming back to make a movie here, after all"- Oliver Stone, as said to The Economic Times, India.
This document contains plans and elevations for proposed additions and alterations to an existing dwelling. It includes drawings showing the east, west, north and south elevations, as well as roof plans, sections and schedules. Dimensions are provided for new construction elements like a walk-in closet and en-suite bathroom. Material specifications and compliance with building regulations are noted.
This document provides construction specifications for a two-storey domestic extension project. It includes 3 key elements:
1) Ground floor construction will be an in-situ cast concrete slab on insulation and damp proof membrane. External walls will be cavity construction with brick outer skin, cavity insulation and block inner skin.
2) Windows and doors will be uPVC units meeting relevant thermal and structural standards. Internal partitions will be blockwork or timber stud walls.
3) The pitched roof will have rafters, insulation, and single-ply membrane. The dormer roof will have an optimized system with insulation and vapor control layer. Services and general works must comply with regulations.
Freelance project management case studies - residentialgrahamelanders
This document contains construction drawings for a proposed residential extension, including:
- Section and detail drawings showing proposed structures like the kitchen aperture support, eaves, substructure, and roof.
- Notes specifying materials and methods for elements like the external walls, windows, drainage, foundations, and more.
- The project aims to gain approval for a new two-story extension to an existing dwelling.
- Freelance project management services included producing the drawings, liaising with structural engineers, and conducting site inspections.
The document contains architectural plans and drawings for the Ice House Hotel project in Ballina, County Mayo, Ireland. It includes floor plans, elevations, and sections for the basement, lower ground, ground, and first floors of the existing building as well as schedules for doors, windows, and areas. Dimensions and technical details are provided for the building elements. The drawings are at scales between 1:100 and 1:1000 and were created by Mark Thornton for his BIM module as part of an architectural technology degree.
This document provides a summary of plans and specifications for a 6 room house with a garage. It includes a project description, list of drawings, general notes on compliance with building codes and dimensions. It also outlines specifications for foundations, floors, walls, ceilings, the roof construction, windows/doors, drainage and other details. The plans were drawn by Robert Ledwaba for client Sengatane Moletjie and include a site plan, elevations, sections and 3D views at a scale of 1:200.
The document provides details on pre-cast concrete panels used in the Whitefriar Rejuvenation Project, including a community centre and creche. The panels play a crucial role in providing insulation and thermal comfort. They act as the skin of the building but require a primary structure for support. In the design, the panels are tied to a cast in situ concrete post and beam structure using heavy duty steel fixings. The panels incorporate features like 120mm PIR insulation, concrete parapets, and are 330mm thick with a 150mm concrete core.
This document contains construction drawings and notes for a two-story home extension project. It includes scale drawings of floor plans and building sections with callouts for materials and construction details. Notes specify that existing foundation depths must be checked on site for possible underpinning. It also provides instructions to remove existing insulation and brick, install new studs and insulation, and ensure cavities are filled before the new floor is laid.
The document is a site plan and specifications for renovations and additions to a property. It includes demolishing some walls, adding new windows and doors, renovating bathrooms, constructing a new garage and boundary walls, and other interior renovations. Dimensions and materials are provided for the new construction. The total existing building area is 227.53 sqm and the new construction will increase this by 72.94 sqm, bringing the total coverage to 31.21% of the 1,197 sqm erf. Health and safety, contractor, and other legal notes are included at the bottom.
This document contains 4 proposed section elevations (A-A through D-D) and 1 proposed section knockout panel for a two-phase home extension project. Section A-A shows elevations for Phase 1 and 2 including a ventilated void, new roof construction details, and floor/ceiling heights. Section B-B shows elevations for Phase 2 including a garage, new roof, and floor/ceiling heights. Section C-C and D-D show elevations for Phase 1 including a stair/void details and new roof. Materials and a site plan are also specified.
The document is a builders drawing showing plans and elevations for a restaurant renovation project. It includes details like dimensions, materials, and notes on fire safety standards. Key information includes plans for the ground floor showing the layout of the main restaurant area, kitchen, toilets, and exterior seating. Notes provide requirements for fire resistance of walls and glazing, means of escape capacities, and toilet provisions to meet building standards.
This document contains a legend and sheet index for architectural drawings of a commercial building project. The legend defines different wall assemblies using materials like metal panels, insulation, steel studs, and CMU. The sheet index lists 9 drawings including site plans, floor plans, elevations, sections, wall details, and stair/elevator plans.
1. The document contains plans for 3 apartments in a new development called Hudson Close Apartments. It includes a ground floor plan showing the layout of the apartments, common areas, and details.
2. The plans show the layout of the individual apartments including bedrooms, bathrooms, kitchens, and living areas. Common areas on the ground floor include a hallway and stairwell.
3. Technical specifications are provided for the building materials and construction methods to be used, including the foundations, flooring, walls, roof, ventilation, and other details.
This document provides a landscape design plan for a residential property. It includes:
1) A site plan showing the proposed landscaping elements such as garden beds, lawn areas, a fire pit, seating, and trees.
2) Planting notes describing soil preparation, mulching, fertilizing, and maintenance requirements.
3) Details for hardscaping elements including paving materials, retaining walls, and irrigation.
4) A list of plant species to be used in the design.
The document provides details for the construction of a freezer including dimensions for walls, panels, supports, and other structural elements. Measurements are given for wall thicknesses, ceiling heights, panel spacings, and other construction specifications. Details are also shown for the roof support system, insulation, vapor barriers, flooring system, and door thresholds.
This document contains architectural drawings for a 3 storey residential building including floor plans, elevations, sections, details and 3D renderings. The drawings show the layout of each floor with room dimensions and labels. Elevations display the external appearance of the building. Sections cut through the building to show internal construction. Details provide closer views of specific building elements like doors, windows and construction assemblies. 3D perspectives and renders demonstrate the proposed design from different angles.
This Installation Guide shows how easy it is to install FloodBreak passive floodgates at vulnerable flood paths and provide permanent flood protection without the need for human intervention or power.
This document contains architectural plans for a proposed two-storey home extension including a ground floor addition of 34.66 square meters and first floor addition of 22.08 square meters. The plans show the layout of the existing house and proposed additions, including new windows, doors, rooflights, and structural elements. Construction details are provided for the foundations, walls, floors, roof, insulation, and materials. The project will update an existing house with a modernized layout and improved energy efficiency.
This document is an architectural design drawing for a proposed two-storey side extension with attached garage at an existing property. The drawing provides details of the proposed ground floor and first floor plans, including new windows, doors, walls and other structural elements. Dimensions and technical specifications are included to fully describe the proposed construction work.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
This document provides plans and notes for a proposed bathroom showroom renovation located at 8A/169 Rosamond Rd in Maribyrnong, Victoria. It includes a locality plan showing the site location, floor plans detailing the existing and proposed layouts, and 44 general notes covering building requirements and regulations. The plans and notes are intended to obtain a building permit for renovating an existing tenancy into a new bathroom showroom.
This document contains a site plan and floor plans for a proposed office block development with the following key details:
- The site plan shows the layout of the proposed development on the site including access, parking, landscaping and boundary details.
- The floor plans show the layout of the ground floor including a reception area, waiting area, tea room, male and female ablutions and office space. Stair access and balustrade details are also shown.
- Notations provide information on compliance with local building regulations and standards covering public safety, accessibility, fire protection and other requirements.
This document contains notes and specifications for a proposed recycling center project. It includes drainage notes, wall construction details, roofing notes, general notes, and notes on compliance with building regulations. Fire protection requirements are also specified referencing sprinklers, signage, emergency lighting, and fire resistance of doors, walls and floors. Dimensions and materials are to be verified on site before construction begins.
Isokern Celsius stove system installation instructionsSchiedel UK
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
The document provides layout details for a foundation slab and notes for a construction project. It specifies an 85mm thick slab throughout with mesh reinforcement and a single pour concrete mix. It notes requirements for strip footings, rebar in slab corners, and refers to architectural drawings for additional details on recesses, drainage and discrepancies. Dimensions are indicative and contractors must confirm wall positions before construction.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
The document is a set of architectural plans to convert an existing garage into a bedroom and make various additions and alterations to an existing dwelling. Key details include raising the garage floor to the level of existing bedrooms, demolishing some walls, adding a new lounge, carport and double garage/storage, and changing some windows, doors and roofing.
This document provides information on ventilated roof insulation products called Vent-Top ThermaCalX1 and Vent-Top ThermaCalX2 manufactured by Cornell Corporation. The products combine oriented strand board and extruded polystyrene insulation with a ventilated air space between. They have a high degree of open area for airflow and moisture diffusion. Installation instructions and code compliance information are also included.
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONSSin Byrne
This document contains floor plans and specifications for upgrades to an existing mill building and silo. It includes floor levels for the existing structure and proposed additions. It then provides details on proposed upgrades to the external walls, floors, windows, silo walls and first/second floors. These upgrades include adding insulation, new flooring materials, triple glazed windows and new cladding to improve energy efficiency. Dimensions and materials are specified.
Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
This document contains drawings and notes for a proposed side and rear extension at an address in Whitchurch, Cardiff. The drawings show the existing and proposed elevations of the front, rear and side of the property. Notes provide details on materials and construction methods to match the existing building, as well as requirements for windows, doors, insulation and ventilation. Key aspects that must be addressed include using materials that match the existing brickwork, render and roof tiles, installing lintels and cavity trays properly, using safety glass where required, meeting energy efficiency standards for windows and doors, and adding trickle vents.
This document provides details of Katie Johnson's portfolio, which includes a final year project investigating using a canal in London to transport imported coffee. The project involves roasting and packaging the coffee in a building located on the canal, with a viewing area for visitors. It also includes a private cinema and coffee shop. Drawings and details are provided for the floor plans, elevations, sections, and other aspects of the design project.
Colin Harkin_Final Year - Project WorkColin Harkin
This document contains design portfolio drawings for an Oasis Infill Design project and a Group Practice Refurbishment project by Colin Harkin. It includes presentation drawings, photos, and descriptions of the proposed facade design for the Oasis project, which takes inspiration from other building designs. It also includes existing demolition plans, proposed plans, elevations, sections and details for the Group Practice refurbishment project.
This document contains architectural plans and details for a residential home renovation project including:
- Proposed ground and first floor plans showing room layouts and dimensions.
- Elevations, sections and details showing building materials, wall assemblies, roof design and fenestration.
- A schedule of windows and doors.
- Notes regarding compliance with building regulations and specifications to be confirmed.
This document contains architectural plans and details for a residential home renovation project including:
- Proposed ground and first floor plans showing room layouts and dimensions.
- Elevations, sections and details of proposed materials, windows and construction methods.
- A schedule of proposed windows.
- Notes regarding compliance with building regulations and engagement of structural engineers.
The document contains architectural plans for a house, including a site plan, floor plan, section, and elevations at scales of 1:75 and 1:100. The single storey house has a main living area of 81.1 square meters along with several bedrooms, bathrooms, and an open front porch. Construction details are provided for the steel column foundations, timber framing, roofing, walls, and other building elements. Dimensions, materials, and technical specifications are annotated on the plans.
Similar to Proposed Builder's Work Plan for Pub/Restaurant (20)
1. JOB REFERENCE
ALLOW FOR NEW 100mm UPVC PIPES
CONNECTED INTO ALL NEW SANITARYWARE
INTO NEW STUB STACK WITH AIR ADMITANCE
VALVE. ALLOW FOR NEW EXTERNAL BELOW
GROUND DRAINAGE TO EXISTING MANHOLE.
(SUBJECT TO SITE INSPECTION)
ALLOW TO REPLACE
EXISTING GLAZING WITH
NEW OBSCURE
FOR TOILET DETAILS REFER
GLAZING.
TO DWG 012.
ALLOW
TO FORM
NEW
WALLS IN
STUDWORK
AS
SHOWN.
ALLOW TO
FORM NEW
OPENING
ALLOW TO FORM NEW
THROUGH,
STUDWORK WALLS AS
MAKE
SHOWN, SKIMMED PLASTER
GOOD FOR
FINISH.
NEW DOOR.
GENTS
ALLOW TO FORM
NEW OPENING
THROUGH, MAKE
GOOD FOR NEW
DOOR.
REMOVE DOOR
AND BLOCK UP
EXISTING OPENING,
PREPARE TO
RECEIVE NEW DECS
REMOVE DOOR
AND BLOCK UP
EXISTING OPENING,
PREPARE TO
RECEIVE NEW DECS
AREA 5
ALLOW TO STRIP
OUT ALL
REDUNDANT
SANITARYWARE
AND CAP OFF
REDUNDANT
SERVICES.
NEW SCREEN,
REFER TO DWG 010.
AREA 4
NEW PLINTH, REFER
TO DWG 010.
ALLOW TO
REMOVE EXISTING
SCREENS & MAKE
GOOD.
NEW PLINTHS, REFER
TO DWG 010.
ALLOW TO FORM
NEW STUDWORK
WALLS AS SHOWN,
SKIMMED PLASTER
FINISH.
PART H-DRAINAGE
EXTRACT FAN WITH PLASTIC DUCTING AS REQUIRED TO TOILETS.
WASHBASIN
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
3 AIR CHANGES PER HOUR.
SINK
50mm DIA 4M MAX RUN
BATH
50mm DIA 4M MAX RUN
TRADING AREA:MECHANICAL ENGINEER TO ADVISE UPON
PROVISION AND CAPACITY OF EXTRACT FANS.
SHOWER
EXISTING FIRE ESCAPE
RETAINED, ALLOW TO
REPLACE EXISTING
DOORS.
HOOD FOR COOKER AND VENTILATION FANS.
URINALS
MANAGERS BATHROOM:ELECTRICAL CONTRACTOR TO SUPPLY
PIPEWORK TO BE IN UPVC TO BS 4514.WASTE RUNS TO BE
AND FIX EXTRACT FAN ,AND PLASTIC DUCTING AS REQUIRED
CONNECTED TO 100mm DIA SOIL AND VENT STACK EXTENDED
FAN TO BE PULL CORD OPERATED AND TO EXTRACTAT A RATE
UP MIN 900mm ABOVE ANY OPENING WITHIN 3M AND FINISHED
OF 15 LITRES/SECOND.
NEW SCREEN, REFER
TO DWG 010.
ALLOW TO BUILD NEW
RECLAIMED BRICKWORK
WALLS AS SHOWN.
ENTRANCE
ALLOW TO DEMOLISH
SECTIONS OF EXISTING
COLUMNS AS SHOWN
AND MAKE GOOD.
AREA 8
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO REMOVE
EXISTING NIB AND
MAKE GOOD.
FOR INTEGRITY ,IN PARTICULAR THE DOOR CLOSER AND
INTUMESCENT STRIP.
ALL APPLIANCES TO HAVE MIN 75mm DEEP SEAL TRAPS.
FAN TO BE CORD OPERATED AND TO EXTRACT AT A RATE OF
APPLIANCE WASTES TO BE TAKEN TO A TRAPPED GULLY IN
PART H-DRAINAGE
NEW WINDOWS TO MANAGERS FLAT TO HAVE TRICKLE
NEW DRAINAGE IN GROUND TO BE VITREOUS CLAY PIPEWORK
VENTILATOR FREE AREA MIN 4000mmSQ.
ALLOW TO FIT
SOLID ASH SHELF
TO REAR GAP
BEHIND FIXED
SEATING.
BAR TO OPEN" NOTICE
N6
H
SMOKE DETECTOR
E
THREE HOUR NON-MAINTAINED EMERGENCY LIGHT FITTING.
"FIRE DOOR KEEP SHUT"NOTICE
CONSTRUCT NEW
FEATURE LOG STORE IN
STUD FRAME AND
PLASTERBOARD CLAD
WALLS TO RECEIVE
SKIM AND DECS.
SINGLE HEIGHT BRICK
PLINTH AND 250mm
DEEP PB CLAD SOFFIT.
HEAT DETECTOR
IP
N1
N5
WHERE PIPE PASSES THROUGH WALL OR FOUNDATION FORM
OPENING THROUGH AND LINTEL OVER.PIPE TO HAVE MIN 50mm
FIRE ALARM INDICATOR PANEL
GENERAL FIRE NOTICE(FIRE
EVENT PROCEDURES)
CLEAR SPACE AROUND.MASK EACH SIDE OF OPENING WITH RIGID
NEW GLAZING TO WINDOWS TO BE 6mm TOUGHENED SAFETY
SHEETING AS RODENT BARRIER.
PIPE RUN IN OPEN GROUND TO HAVE MIN 150mm PEA GRAVEL
BED AND SURROUND.
PARTICULAR DETAILS TO HANDRAILS AND TACTILE
MANHOLES CONSTRUCTED OF 215mm SEMI-ENGINEERING
BRICKWORK TO BS 3921,BUILT OFF 150mm CONCRETE SLAB
WITH CONCRETE FLAUNCHING TO PIPEWORK.
INTERNAL PIPEWORK TO HAVE DOUBLE SEAL COVER WITH
DISABLED TOILET TO DIMENSIONS SHOWN BELOW.
Gateway, Eastleigh
"FINAL FIRE EXIT"
"EXIT"
9 LITRE WATER EXTINGUISHER
"FIRE EXIT"
DRAWING TITLE
"EXIT,LEFT"
AFFF FOAM EXTINGUISHER
"FIRE EXIT,LEFT"
"EXIT,RIGHT"
B
2
1m FIRE BLANKET
"FIRE EXIT,RIGHT"
NEOPRENE GASKET.COVER TO BE RECESSED TO ACCEPT FLOOR
ILLUMINATED 3 HOUR MAINTAINED
TIMBER STUD PARTITION-30 MINUTES
NEW PARTITION OF 89x38mm SW HEAD AND SOLE PLATES
NOGGINS @ 1200mm c/c.FACE EACH SIDE WITH ONE LAYER
WET CHEMICAL
12.5mm GYPROC WALLBOARD PLASTERBOARD,JOINTS TO BE TAPED
TO BS 5499 PART 1 (THE GREEN MOVING
CEILING
CONTRACTOR TO DEMOLISH EXISTING STRUCTURE AS INDICATED
WHERE DOWNLIGHTERS ARE TO BE USED.
AND FOR TEMPORARY SUPPORT OF STRUCTURE AS REQUIRED BY
ALLOW FOR AT LEAST 130-140mm DROP.
FINISH WITH SKIM PLASTER TO RECEIVE DECORATION.
PERSON),EUROPEAN DIRECTIVE.
ACHIEVES HALF HOUR FIRE RESISTANCE.
WHERE RUN OF STUD PARTITION IS PARALLEL WITH JOIST
STRUCTURAL ENGINEER.CART AWAY DEBRIS AND MAKE GOOD TO
AFFECTED SURFACES.
SCALE
1:50
SHEET
A1
RUN ON TIMBER FLOOR EXPOSE FLOOR AND DOUBLE UP
ALLOW FOR A SACRIFICIAL CEILING TO ALL AREAS OF CEILING
BY BROKEN LINE.ALLOW FOR PROTECTION OF REMAINING FABRIC,
Proposed Builders Work
WITH 89x38mm SW STUDS @ 600mm c/c AND 89x38mm SW
w c
EMERGENCY EXIT SIGN.LEGENDS TO BE
DEMOLITION
Whitbread Plc.
4.5kg DRY POWDER EXTINGUISHER
NEW MANHOLES TO MIN INTERNAL SIZE OF 1200x750mm WITH
MIN 600x600mm COVER.EXACT SIZE AS DRAWING.
CLIENT
CARBON DIOXIDE FIRE EXTINGUISHER
"FINAL EXIT"
FOUNDATION UNDERSIDE.
ADS DESIGN & BRAND DEVELOPMENT
King John's Gallery, Mythe Road, Tewkesbury, GL20 6EB
Tel: +44 (0) 1684 851299 Fax: +44 (0) 1684 851298
email: info@ads-design.co.uk
PROJECT
SERVICEABILITY
PIPE WITH 150mm CONCRETE BED AND SURROUND TO LEVEL OF
KJA
"FIRE DOORS KEEP CLEAR" NOTICE
BE CHECKED AND CERTIFIED (QUALIFIED ELECTRICIAN) FOR
REF TO DOOR SCHEDULE FOR FULL DETAILS
SHEET OF TOUGHENED GLASS.
11/7/07
ALLOW TO INFILL GAP WITH SW
FRAMEWORK CLAD IN
PLASTERBOARD SKIMMED AND
PAINTED FINISH TO MATCH
ELSEWHERE.
BREAK GLASS FIRE ALARM CALL POINT.
GLASS TO BS6206 1981, TO A MINIMUM HEIGHT OF 1500mm
GLAZED SCREENS WITH LEADED GLASS TO BE BACKED WITH
DISABLED WC LAYOUT REVISED, NEW
WINDOW IN AREA 5 OMITTED, EXISTING
RETAINED WITH WORKS, SCREEN IN AREA 13
REVISED TO INCORPORATE EXISTING
SERVICES DUCT, DOOR INTO FIRE EXIT
STAIRS BLOCKED UP, REVISIONS TO GENTS
WC.
ADSDESIGN
ALL EXISTING EMERGENCY LIGHTING WHICH IS REMAINING TO
WHERE PIPE RUNS WITHIN 1M OF BUILDING FOUNDATION,ENCASE
KJA
LOBBY
PANIC BOLT EMERGENCY DOOR IRONMONGERY,WITH"PUSH
NEW GLAZING TO DOORS TO BE OF 6mm TOUGHENED SAFETY
GLASS AS BEFORE TO MIN HEIGHT OF 800mm
13/7/07
VISION PANEL TO DOOR OF 6mm GEORGIAN WIRED POLISHED
OF 100mm DIA LAID TO FALL 1:80 (UNLESS OTHERWISE NOTED
PIPE WORK IN FLOOR TO HAVE MIN 150mm CONCRETE BED AND
LOG STORE ADDED TO LOBBY. SCREENS IN
AREAS 12,4 & 9 AMENDED.
A
BELOW GROUND
ON DRAWING).CLAY PIPES TO BS 85
KJA
INTERIORS ARCHITECTURE
VP
TRICKLE VENTILATOR FREE AREA MIN 4000mmSQ.
FANS,TOGETHER WITH LINTELS,DPCS AND CAVITY TRAY.
19/7/07
PLATE GLASS,OR PILKINGTON "PYRAN" FIRE RESISTANT
S
FLOOR /GROUND, TO BE FITTED WITH A SEALING PLATE.
AMENDMENT TO FIXED SEATING BY MAIN
ENTRANCE.
B
NEW PLINTH,
REFER TO DWG
010.
GLASS,SET IN INTUMESCENT PUTTY WITH HARDWOOD BEADS.
VALVE TO A BBA CERTIFICATE.
MINIMUM DIMENSIONS OF LOBBIES AND RAMPS AND OF
C
AND DETECTORS SUBJECT TO FIRE OFFICERS REPORT.
AND FIX EXTRACT FAN AND PLASTIC DUCTING AS REQUIRED.
REFER TO DRAWINGS FOR PROVISION OF ACCESS INCLUDING
RETAIN EXISTING SERVICE
DUCT AND STUDWORK.
NEW PLINTH, REFER
TO DWG 010.
ALL EXISTING FD30S,AND FD60S FIRE DOORS TO BE CHECKED
PB
LIVING ROOM
ALLOW TO REMOVE
EXISTING SCREENS AND
MAKE GOOD TO WALLS &
FLOOR.
NOTE THAT THE EXACT LOCATION OF EMERGENCY LIGHTING
MANAGERS KITCHEN:ELECTRICAL CONTRACTOR TO SUPPLY
PART M-DISABLED
ALLOW TO STRIP OUT ALL
EXISTING RAISED LEVEL
AND MAKE GOOD TO
AFFECTED AREAS. ALLOW
TO MAKE GOOD FLOOR
READY TO RECEIVE NEW
FLOOR FINISH.
UPON COMPLETION OF TREATMENT.
50mm DIA 4M MAX RUN
100mmSTUB STACKS TO BE FITTED WITH AN AIR ADMITTANCE
PART N-GLAZING
NEW SCREEN, REFER
TO DWG 010.
STANDARD.CONTRACTOR TO SUPPLY FIRE TEST CERTIFICATE
WITH BALLOON GRATE.
MAIN CONTRACTOR TO FORM OPENINGS INWALLS/ROOFS FOR
KITCHEN
WITH PROPRIETRY TREATMENT TO A BBA CERTIFICATE
DOOR KEEP SHUT" NOTICE BOTH SIDES AT EYE LEVEL.
50mm DIA 4M MAX RUN
KITCHEN
LOBBY
UPHOLSTERY ETC) TO BE UPGRADED TO CLASS"1" STANDARD
IF PLANTED).POSITIVE OVERHEAD DOOR CLOSER."FIRE
GLASSWASH
NEW CABINETRY
REFER DRAWING No11
CLASS "0".CLASS "3" ITEMS(EG CURTAINS,DRAPES,TIMBER,
AT 300mm CENTRES MAX WITH COUNTER SUNK SCREWS
WASHMACHINE 50mm DIA 4M MAX RUN
3. The contractor is responsible for ensuring that all works comply with Local Authority
requirements and national regulations.
SURFACE SPREAD OF FLAME:WALLS AND CEILINGS TO BE
FRAME /LINING TO HAVE MINIMUM 38x15mm STOPS(FIXED
50mm DIA 4M MAX RUN
2. This drawing should be read in conjunction with relevant specifications and documentation
issued by ADS Design or third parties. the contractor is responsible for assimilating the
information and reporting descrepancies to ADS Design prior to commencement of works.
NEW PLINTH, REFER
TO DWG 010.
NEW PLINTHS, REFER
TO DWG 010.
ALLOW TO REPLACE
EXISTING GLAZING WITH
NEW OPAQUE GLAZING
TO DESIGNERS
APPROVAL.
INTUMESCENT STRIPS AND COLD SMOKE SEAL BRUSHES.
KITCHEN:CATERING CONTRACTOR TO ADVISE UPON EXTRACTION
60 LITRES/SECOND.MAIN CONTRACTOR TO SUPPLY AND FIX
NEW SCREEN,
REFER TO DWG
010.
FIRE DOOR TO HALF HOUR FIRE RESISTANCE WITH
FD30S
40mm DIA 3M MAX RUN
ALLOW TO FORM NEW
STUDWORK NIB FOR NEW PLINTHS,
REFER TO DWG 010 FOR DETAILS.
NEW SCREENS, REFER
TO DWG 010.
AREA 9
PART B-FIRE NOTES
PLUMBING SIZES:
FAN TO BE SWITCHED TO TOILET LIGHTS AND TO ACHIEVE
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO FORM
NEW STUD WALL AS
SHOWN, SKIMMED
PLASTER FINISH.
ALLOW FOR NEW
DOORWAY.
ALLOW TO
CAREFULLY DEMOLISH
EXISTING WALL AS
SHOWN AND MAKE
GOOD.
AREA 1
NEW PLINTH, REFER
TO DWG 010.
NEW SOLID STUD
WALL PREPARED TO
RECEIVE NEW DECS
ABOVE GROUND
NEW
SCREEN,
REFER TO
DWG 010.
1. Do not scale from this drawing. All dimensions should be checked on site prior to
commencement of work or associated manufacturing.
ALLOW TO REMOVE
EXISTING DOOR &
FRAME AND MAKE
GOOD.
ALLOW TO FORM
NEW STUDWORK
WALLS AS SHOWN,
SKIMMED PLASTER
FINISH.
ALLOW TO FORM NEW
STUDWORK WALLS AS
SHOWN, WITH SKIMMED
PLASTER FINISH.
ALLOW TO
FORM NEW
COLUMN FROM
BRADSTONE.
ALLOW TO REMOVE
EXISTING SCREEN AND
MAKE GOOD.
PURPLE ROOM
TOILETS:ELECTRICAL CONTRACTOR TO SUPPLY AND FIX
AREA 7
ALLOW TO
FORM NEW
COLUMN FROM
BRADSTONE.
NEW SCREENS,
REFER TO DWG
010.
ALLOW TO FORM NEW
STUDWORK WALLS AS
SHOWN WITH SKIMMED
PLASTER FINISH.
NEW SCREEN REFER TO
DWG 010. ALLOW TO
FORM 2NO. NEW
STUDWORK PIERS AS
SHOWN.
Copyright of this drawing is owned soley by ADS Design & Brand Development Ltd.This
document is confidential and as such its contents should be treated with the utmost care
and consideration, and in no circumstances should it be disclosed, distributed, published or
copied whether in part or in whole, without the prior consent of ADS Design and Brand
Development Ltd in writing.
NEW SCREEN,
REFER TO DWG
010.
AREA 10
PART F-VENTILATION
ALLOW TO INFILL GAP WITH
STUDWORK, SKIMMED
PLASTER FINISH.
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO CAREFULLY
DEMOLISH EXISTING WALLS
AS SHOWN, MAKE GOOD
TO AFFECTED AREAS.
NEW SCREENS,
REFER TO DWG
010.
ALLOW TO CAREFULLY
REMOVE EXISTING
COLUMN AND MAKE
GOOD.
AREA 2
ALLOW TO FORM NEW STUDWORK
NIB FOR NEW SCREEN & PLINTH, REFER
TO DWG 010 FOR DETAILS.
NEW SCREEN,
REFER TO DWG
010.
APPROXIMATE
POSITION OF NEW
WHB, ALLOW FOR
CONNECTION INTO
DRAINAGE RUN.
ALLOW TO REMOVE ALL
EXISTING BAR SERVERY
AND MAKE GOOD TO
AFFECTED AREAS.
NEW SCREEN AND
DRINKSHELF,
ALLOW TO
REFER TO DWG
REMOVE
010.
EXISTING
SCREEN AND
MAKE GOOD.
NEW FIREPLACE,
REFER TO DWG
013.
ALLOW TO REMOVE
EXISTING SCREEN &
MAKE GOOD.
NEW PLINTH,
REFER TO DWG
010.
ALLOW TO FORM
NEW COLUMN
FROM BRADSTONE,
TO ENCLOSE NEW
STRUCTURAL STEEL
ALLOW TO
CAREFULLY
DEMOLISH EXISTING
WALL AS SHOWN
REMOVE DOOR &
FRAME, MAKE
GOOD TO
AFFECTED AREAS.
BLUE ROOM
AREA 11
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO REMOVE ALL
EXISTING BAR SERVERY
AND MAKE GOOD TO
AFFECTED AREAS.
BAR SERVERY
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
NEW ATM
ENCLOSURE REFER
DRAWING No 11
AREA 6
NEW WALLS TO
COMPLETELY
ENCLOSE NEW
STRUCTURAL STEEL
COLUMNS AS PER
ENGINEERS SPEC
ALLOW TO CAREFULLY REMOVE EXISTING
COLUMN AND MAKE GOOD.
NEW BAR SERVERY AND
BACKFITTING, REFER TO
DWGS 07 & 08.
BAR
AREA 6
NEW SCREEN, REFER
TO DWG 010.
ALLOW TO DEMOLISH
EXISTING SCREEN & WALLS
AND MAKE GOOD. REROUT
EXISTING SEVICES INTO NEW
STUD WALL
ALLOW TO
CAREFULLY DEMOLISH
EXISTING WALLS AS
SHOWN AND MAKE
GOOD.
ALLOW TO DEMOLISH
EXISTING WALLS AS
SHOWN & MAKE GOOD.
ALLOW TO STRIP OUT ALL
REDUNDANT
SANITARYWARE AND CAP
OFF REDUNDANT SERVICES.
ALLOW TO DEMOLISH EXISTING WALLS
AND SERVICE DUCT AS SHOWN.
ALLOW TO RE-ROUTE SERVICES.
AREA 12
RED ROOM
ALLOW TO REMOVE ALL EXISTING
BAR SERVERY AND MAKE GOOD
TO AFFECTED AREAS.
ALLOW TO FORM
2NO NEW
RECLAIMED
BRICKWORK PIERS
AS SHOWN.
AREA 13
ALLOW TO STRIP
OUT EXISTING
BATHROOM AND
CAP OFF EXISTING
SERVICES,
CAREFULLY
DEMOLISH EXISTING
WALLS AS SHOWN
AND MAKE GOOD.
BAR
ALLOW TO REMOVE
EXISTING SCREENS &
MAKE GOOD.
NEW SCREEN,
REFER TO DWG 010.
ALLOW TO INFILL REDUNDANT DOORWAY
WITH STUDWORK, SKIMMED PLASTER FINISH.
NEW STUD WALLS TO
COMPLETELY
ENCLOSE NEW
STRUCTURAL STEEL
COLUMNS AS PER
ALLOW TO FORM
ENGINEERS SPEC
NEW WALL FROM
BRADSTONE
STONEWORK.
NEW POSEUR
DINING SHELF, REFER
TO DWG 011.
ALLOW TO
DEMOLISH EXISTING
WALLS AS SHOWN &
MAKE GOOD.
NEW STUDWORK WALLS AS
SHOWN, SKIMMED PLASTER
FINISH.
ALLOW TO FORM
NEW STUDWORK
COLUMN AS
SHOWN, SKIMMED
PLASTER FINISH.
ALLOW TO FORM
NEW WALLS IN
STUDWORK AS
SHOWN.
AREA 4
ALLOW TO REMOVE
EXISTING DOOR &
FRAME AND MAKE
GOOD
ALLOW TO INFILL
REDUNDANT
DOORWAY WITH
NEW STUDWORK,
SKIMMED PLASTER
FINISH.
BROWN ROOM
NEW SCREENS,
REFER TO DWG 010.
LADIES
DISABLED
WC
ALLOW TO STRIP OUT ALL
REDUNDANT
SANITARYWARE AND CAP
OFF REDUNDANT SERVICES.
FOR TOILET DETAILS
REFER TO DWG 012.
NEW DRAINAGE AS
PER NOTE ABOVE.
07041
RETAIN EXISTING WINDOW, REGLAZE
WITH BLACK GLASS. BLOCK UP
INTERNALLY WITH STUD FRAME AND
PB CLADDING. SKIM ENTIRE WALL IN
PREP FOR NEW DECS
FIRE PROTECTION-STEELWORK
PROTECT STEELWORK WITH ONE
LAYER OF GYPROC 12.5MM FIRELINE
PLASTERBOARD FIXED TO GYPROC
Gyplyner "ENCASE" STEEL CLIP
SYSTEM FIXED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
JOIST UNDER.
DATE
June 07
DRAWN
Autocad2000/
DRAWING NUMBER
016
C