1. M
M
VFD
VFD
M
(NOTE 2)
M
M
1011
FIC
0002
LIT
1011
FIT
0005
PIT
I LCS
I AG700M
XU
I
I PP702M
XU
PP701M
XU
1027
ZS
1026
ZS
1030
LSH
1029
LSM
1021
PDIT
1022
PIT
M TURBIDITY
I
I
M
0005
FIT
0005
FIC
FAH
0002
LIC
LAH
LAHH
1024
AE
1024
AIT
1025
LSL
LCS
LCS
0005
PI
0005
PSH
1028
ZS
0002
LSLL
0010
LIT
0010
LAHL
0010
LI
ILCS
PP715M
XU
0010
LE
I
0025
AE
0025
AIT
0025
AI AAH
AAL
1023
PI
II
I I LCS
PP703M
XU
2213
FROM RESIDUE THICKENER
OVERFLOW PUMPS
284-PP-085/086
284-PI-T-004
2164
TO PLS TANKS
291-TK-705/706
291-PI-T-003
2158
FROM RAW WATER HEADER
262-PI-T-007
2159
FROM HYDROMET AREA
PLANT AIR DISTRIBUTION
265-PI-T-006
1947
FROM ACD SOLUTION PUMPS
284-PP-081/082
284-PI-T-001
2157
FROM PLS FILTER
PRECOAT TANK
291-TK-704
291-PI-T-002
2163
TO PLS FILTER SLUICE TANK
291-TK-707
291-PI-T-002
2155
FROM CAUSTIC BOIL FIRST
BOTTOMS COOLER
288-HX-114
288-PI-T-104
2161
TO PLS TANKS
291-TK-705/706
291-PI-T-003
2162
TO PLS FILTER PRECOAT TANK
291-TK-704
291-PI-T-002
2454
TO ACD FILTRATE
TRANSFER TANK
284-TK-076
284-PI-T-007
2511
FROM 291-LIC-0041
291-PI-T-002
2762
TO COLLECTION DITCH
255-PI-T-007
LAL
LALL
TO FLOOR
OVERFLOW
OVERFLOW
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. REMOVABLE SPLIT COVER.
TO FLOOR
PAH
FAL
VENT TO ATM
(STANDBY)
S/D
V
V
V
FC
V
FC
HV
1005
+
V
FC
V
FC
V
V
V
V
FE
1011
+
FV
1011
+
V
SLOPE
6"x4"6"x4"
291-AG-700
291-TK-700
PLS MIX TANK
291-TK-701
PLS FILTER
FEED TANK
291-AG-700
PLS MIX TANK
AGITATOR
291-PP-701
PLS FILTER
FEED PUMP
291-PP-702
PLS FILTER
FEED PUMP
(STANDBY)
FC
V
V
FC
V
3"-C-22
V
V
V
3"-SPH-15
291-PP-701
291-PP-702
291-FL-701
291-TK-700
291-TK-701
6"x3"
6"x3"
HV
1007
+
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
FILTRATION
291-PI-T-001
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-001MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
SOLVENT EXTRACTION FLOWSHEET291-FS-T-001
INSTRUMENTATION LEGEND, P&ID
PLS
291-PI-T-001
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
07/27/10
RC
DD/JHL
MMB
ZDM / EAD
01/28/11JHLDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND, P&ID000-PI-T-001
4
6"-C-23
6"-C-23
6"-A-15A-GO
HV
1008
+
PCV
1016
+
HV
1009
+
HV
1003
+
HV
1004
+
6"-ASLL-291-052-S1
291-FL-701
PLS FILTER
PACKAGE
291-PP-715
PLS SUBMERSIBLE
SUMP PUMP
FE
0005
+
2"
4"
1"-AA-291-014-L6-PP
-PP
6"-ASLL-291-045-S1
6"-ASLL-291-045-S1
6"-ASLL-291-044-S1
1"-A-15
1"-A-15
1"-A-15
NC
NC
NC
NC
V
V
4"-RW-291-048-L1B
6"-PD-291-025-P1
4"-A-85
2"-A-85
4"-A-15A
8"-PD-291-026-P1
8"-ASLH-291-042-F5
6"-ASLL-291-046-S1
6"-ASLL-291-047-S1
3"-PA-265-148-L8B
6"-ASLL-291-001-S1
6"-ASLL-291-030-S1
1"-A-15
1"-A-15
NC
1"-A-15
NC
6"-A-15-GO
6"-A-15-GO
6"-A-15-GO
NC
4"-A-15
4"-C-224"-A-16A
NC
09-05-2012 9:00:31
V
FC
FC
V
V
291-PK-001
291-PK-001
PLS FILTER
FEED PUMP
SKID PACKAGE
LFF1
291-PP-715
LFF1
LVF1
LVF1
V1Z
3"-A-15A
HV
0024
+
3"-A-15
3"-A-15
V1Z
V1ZV1Z
V1Z HV
0022
+
HV
0021
+
HV
0023
+
6"-PSH-291-003-S1
HV
1001
+
pH
V
3"-A-16A
4"-SPJ-1H
4"-SPJ-1H6"x4"
6"x4"
3"-K-1
3"-C-23
3"-SU-291-024-P7
FV
1010
+
V
HV
1002
+NC
6"x4"
6"-A-16
4"x3"
4"-SPJ-1
LFF1
6"-RW-262-044-L1B
291-PP-703
291-PP-703
PLS FILTER
FEED PUMP
3"x1-1/2"
6"-A-15-GO 6"-A-15-GO
6"-PSH-291-002-S1
3"-SLN-284-003-L5
4"-ASH-284-003-F5
3"-SU-291-020-P73"-SU-291-020-P7
3"x2"
4
4
4
4
2. M
M
M
M
VFD
VSD
I
PP707M
XU
I PP704M
XU
I
LCS
0047
LSL
0046
PIT
0041
LIT
I
0041
LIC
LALL
LAHH
AG704M
XU
I
LCS
I
0047
LE
0047
LIT
0047
LSH
ILCS
I
AG707M
XU
LCS
LCS
IIBG704M
XU
0046
PI
PAH
PAL
0048
FI
0049
PI
PAH
0049
PIT
0041
LSLL
0049
PSHH
PAHH
BG704M
SIC
M
0048
FIT
0041
LSL
2157
TO PLS FILTER
291-FL-701
291-PI-T-001
2162
FROM PLS FILTER
291-FL-701
291-PI-T-001
2163
FROM PLS FILTER
291-FL-701
291-PI-T-001
2460
TO RESIDUE REPULP TANK
284-TK-071
284-PI-T-005
2166
TO ACD FILTRATE
TRANSFER TANK
284-TK-076
284-PI-T-007
2511
TO PLS FILTER PLC
291-PI-T-001
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 00-PI-T-001.
2. REMOVABLE SPLIT COVER, FRP.
START
STOP
TO FLOOR
TO FLOOR
LAHH
(NOTE 2)
(NOTE 2)
1 M
08-05-2012 17:11:38
291-TK-704
PLS FILTER
PRECOAT TANK
291-AG-704
PLS FILTER PRECOAT
TANK AGITATOR
291-PP-704
PLS FILTER
PRECOAT PUMP
291-TK-707
PLS FILTER
SLUICE TANK
291-AG-707
PLS FILTER SLUICE
TANK AGITATOR
291-PP-707
PLS FILTER
SLUICE PUMP
LVF1
LFF1
291-PP-707
291-TK-707
291-AG-707
LFF1
LFF1
291-TK-704
291-AG-704
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
PRECOAT AND SLUICE
291-PI-T-002
291-SOLVENT EXTRACTION
P & ID
3
2
B
1
0
05/05/12RCMMBAPPOBM
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION
UPDATED & RE-ISSUED FOR CONSTRUCTION
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-002MECHANICAL EQUIPMENT LIST, REV. U000-EL-M-001
SOLVENT EXTRACTION FLOWSHEET291-FS-T-001
INSTRUMENTATION LEGEND, P&ID
PLS FILTER
291-PI-T-002
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
07/27/10
RC
JHL
MMB
ZDM / EAD
01/28/11DDDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND, P&ID000-PI-T-001
3
2"-A-15
2"-A-15
NC
3"x1-1/2" 2"x1-1/2"
2"-ASLL-291-034-S1
291-PP-704
4"-A-15A-GO
6"-C-23
6"-PSH-291-003-S1
8"-PD-291-027-P1
4"-A-15A 2"-A-15
2"-A-15
NC
NC
6"-ASLL-291-030-S1
2"-ASLL-291-032-S1
1"-A-15
6"-ASLL-291-052-S1
6"-A-15-GO
1"-A-15
NC
6"-A-15-GO
8"-PD-291-028-P1
4"-A-15A
NC
3"-A-15A
3"-ASLL-291-031-S1
1"-A-15 1"-A-15
NC NC
1"-A-15
8"x4"
3"-A-15A
LFF1
FE
0048
+
NC
1"-A-151"-A-15
NC
1"-A-15
NC
1"-A-15
NC
6"x4" 6"x4"
3"
4"-ASLL-291-051-S1
291-PK-002
291-PK-002
PLS FILTER
PRECOAT PUMP
SKID PACKAGE
6"-ASLL-291-052-S1
6"-ASLL-291-052-S1
M
291-BG-704
291-SC-704
291-CH-704
291-BG-704
PLS FILTER PRECOAT
BAG UNLOADER
291-SC-704
PLS FILTER PRECOAT
SCREW FEEDER
291-CH-704
PLS FILTER PRECOAT
TANK FEED CHUTE
291-HS-704
291-HS-704
PLS FILTER PRECOAT
HOIST
6"x4"
3
3
3. M
M
VFD
VFD
0085
FIC
FAL
0082
LIT
0083
LIT
0082
LIC
LAHH
0083
LIC
LAHH
LAH
LAL
I
I
I
I
PP706M
XU
PP705M
XU
LCS
LCS
M
0085
FIT
0082
LSL
0089
TE
0088
TE
RTD
0088
TIT
0089
TIT
0089
TI LAH
0088
TI TAH
0083
LSL
I
0085
HS
2164
FROM PLS FILTER
BYPASS
291-PI-T-001
2210
TO E-1 PUMP MIX TANK
291-TK-713
291-PI-T-004
2161
FROM PLS FILTER
291-FL-701
291-PI-T-001
2462
RATIO CONTROL
TO 291-FFIC-0186
291-PI-T-008
2470
MANUAL RATIO CONTROL
TO 291-FDI-0131/0132
291-PI-T-005
LAH
LAL
8" X 8" 8" X 8"
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK
TABLE, 000-LT-I-205, AT A LATER DATE.
TO FLOOR
TO FLOOR
(STANDBY)
SAMPLING
NC
6"-PSH-291-037-S1
291-SA-011
291-SA-011
Mo SX PLS FEED
SAMPLER
NC
NC
1"-SPH-6A
6"-PSH-291-033-S1
1"-A-15
6"-A-15-GO
6"-A-15-GO 6"-A-15-GO
1"-A-15
1"-A-15
6"-A-15-GO
1"-A-15
6"-PSH-291-034-S1
6"-PSH-291-036-S1
6"-PSH-291-002-S1
6"-PSH-291-030-S1
6"-A-15A-GO 6"-A-15A-GO
6"-A-15A-GO
6"-A-15A-GO
6"-A-15A-GO
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
PLS FEED
291-PI-T-003
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/30/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-003
MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
INSTRUMENTATION LEGEND, P&ID
291-PI-T-003
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
08/20/10
RC
JHL
MMB
ZDM / EAD
01/28/11DDDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND, P&ID000-PI-T-001
4
FE
0085
+
NC NC
NC
NC
NC
NC
NC
4" 4"
6"-PSH-291-037-S1
291-PP-705
291-PP-706
291-PP-705
PLS FEED PUMP
291-PP-706
PLS FEED PUMP
(STANDBY)
6"-PSH-291-032-S1
6"-A-15-GO6"-C-23
6"-C-23
6"-A-15-GO
1"-A-15
1"-A-15
6"x4"
6"x4"
28-04-2012 13:58:28
6"-ASLL-291-001-S1
6"-PSH-291-035-S1
6"-A-15-GO
6"-PSH-291-031-S1
1"-A-15
1"-A-15
NC
NC
291-PK-003
291-PK-003
PLS FEED PUMP
SKID PACKAGE
PP
3"-A-15A
LVF1
6"-A-15A-GO
LVF1
NC
3"-A-15A
291-TK-705 291-TK-706
291-TK-705
PLS TANK
291-TK-706
PLS TANK
6"x4" 6"x4"
8"-PD-291-029-P1
RTD
6"-PSH-291-002-S1
6"-PSH-291-002-S1
8"-PD-291-030-P1
3029
(VENDOR FOAM SYSTEM)
FROM SX PLANT
S/D INTERLOCK
(NOTE 2)
S/D
S/D
S/D
3
3
6"-SPJ-1H
6"-SPJ-1H
4
4
4
4
4. M M
VFD VFD
M M
VFDVFD
AQ OR AQ OR
(NOTE 3)
LCSLCS II
I
I
0111
CI CAH
I
I
0113
LSHH
LAL
0113
LS
AG711M
XU
AG710M
XU
I
LCS
AG714M
XU
AG713M
XU
LCSI
0115
LS
0115
LSHH
LAL
I
I
0120
LIT
PP710M
XU
0120
LE
I
0120
LAH
0120
LI
ILCS
AG710M
SIC SAH
SAL AG711M
SIC SAH
SAL AG713M
SIC SAH
SAL
AG714M
SIC SAH
SAL
0111
CE
0111
CIT
0114
CI CAH
0114
CIT
0114
CE
0112
CI
0112
CE
0112
CIT
0116
CE
0116
CIT
0116
CI
0118
LE
0118
LIT
0118
LI
0117
LI
0117
LE
0117
LIT
2219
TO SCRUB MIX TANK
291-TK-716
291-PI-T-005
2222
TO EXTRACTION
CRUD TANK
291-TK-738 VIA
291-PI-T-005
2210
FROM PLS FEED PUMPS
291-PP-705/706
291-PI-T-003
2225
FROM BARREN ORGANIC
PUMPS
291-PP-733/734
291-PI-T-008
2252
TO EXTRACTION CRUD TANK
291-TK-738
291-PI-T-014
2253
TO RAFFINATE TANKS
291-TK-707/709
291-PI-T-010
2434
FROM RAFFINATE ORGANIC
RECOVERY PUMP
291-PP-745
291-PI-T-010
2435
TO RAFFINATE
DIVERSION BOX
291-DI-708
291-PI-T-010
2691
VIA COLLECTION DITCH
TO EMERGENCY POND
255-PD-001
255-PI-T-007
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. ORGANIC RECOVERY DISCHARGE TO SETTLER
FEED LAUNDER.
3. SEE MECHANICAL DRAWINGS FOR WEIR ACCESS
HATCH DETAILS.
LAH
LAHH LAHH
LAH
(NOTE 2)
( NOTE 3)
M
CAH
CAL
TO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
3"-SPH-20
3"-C-23
3"x2"
NC
2"-A-15
2"-A-15
NC
2"-A-15
NC
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
EXTRACTION
291-PI-T-004
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-004
MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
INSTRUMENTATION LEGEND P&ID
MOLYBDENUM
291-PI-T-004
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
08/25/10
RC
JHL
MMB
ZDM/EAD
01/28/11DDDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND P&ID000-PI-T-001
4
6"-PSH-291-037-S1
2"
4"-A-15
2"-A-15
NC
NC
6"-B-4-GO-E72
6"-B-4-GO-E72
NC
291-AG-710
4"-A-15
6"-B-4-GO
6"-B-4-GO
291-TK-712
291-TK-711291-TK-710
291-AG-711 291-AG-713
6"-B-4-GO
6"-B-4-GO-E72
291-TK-715
6"-B-4-GO
4"-A-15
4"-A-15
291-AG-714
291-TK-713
2"-A-15
6"-B-4-GO-E72
291-TK-714
NC
NC
NC
NC
2"-A-15
6"-WBO-291-004-S1
6"-WBO-291-005-S1
4"-LO-291-060-S1
6"-PSH-291-004-S1
6"-LO-291-001-S1
6"-ABS-291-010-S1
4"-LO-291-002-S1 6"-LO-291-003-S1
6"-ABS-291-010-S1
2"-ACC-291-001-S1
2"-ACC-291-002-S1
2"-ACC-291-001-S1
4"-B-4-GO-E72
NC
4"-B-4-GO-E72
NC
3"-ACC-291-020-S1
3"-ABS-291-007-S1
NC
NC
NC
1"-A-15
1"-A-15
291-PP-710
3"-A-15
3"-A-15
LFF1
6"-B-4-GO
NC
4"-ABS-291-013-S1
6"-PSH-291-014-S1
6"-PSH-291-009-S1
6"-B-4-GO
6"-B-4-GO
6"-B-4-GO
NC
NC
NC
291-TK-710
E-2 PUMP MIX
TANK
291-AG-710
E-2 PUMP MIX
TANK AGITATOR
291-TK-711
E-2 AUXILIARY
MIX TANK
291-AG-711
E-2 AUXILIARY
MIX TANK
AGITATOR
291-TK-712
E-2 SETTLER
TANK
291-TK-713
E-1 PUMP
MIX TANK
291-AG-713
E-1 PUMP
MIX TANK
AGITATOR
291-TK-714
E-1 AUXILIARY
MIX TANK
291-AG-714
E-1 AUXILIARY
MIX TANK
AGITATOR
291-TK-715
E-1 SETTLER
TANK
SLOPE
LVF1 LVF1 LVF1 LVF1
07-05-2012 14:59:32
1"-A-15
NC
1"-A-15
NC
2"-SPH-6A
3"-ABS-291-003-S1
291-PP-710
SX EXTRACTION
SUBMERSIBLE SUMP PUMP
3"-A-15
3"-A-15
3"-A-15
3"-ACC-291-020-S1
3"-ABS-291-007-S1
2"-SPH-6A
NC
4
4
4
4
4 4
5. VFD
MM M M
VFD VFD VFD
AQ OR
( NOTE 2)
AQ OR
0123
LSHH
0124
AI
AAL
AAH
0123
LI
LAL
0123
LE
0127
LE
0123
LIT
0127
LIT
0128
AE
0124
AIT
0128
AIT
0124
AE
0128
AIC
AAH
AAL
0127
LI
LAHH
LAH
0121
CE
0125
CE
0125
CIT
M
0121
CIT
I
I
LCS
AG717M
XU
I
LCS
AG719M
XU
I
AG720M
XU
I
LCSI
0131
FIT
0122
CI CAH
0122
CIT
0122
CE
M
0129
FIT
0129
FI
0130
FIT
0130
FIC
0121
CI
CAH
0125
CI CAH
0127
LSHH
I
I LCS
AG716M
XU
0126
CI
CAL
0126
CE
0126
CIT
0131
FI FAH
FAL
M
0132
FI
FAL
FAH
M
0131
FD
FDAL
0132
FD
FDAL
AG716M
SIC
AG717M
SIC
AG719M
SIC
AG720M
SIC
0128
HIC
0131
HIC
0132
HIC
0132
FIT
2219
FROM E-1 SETTLER TANK
291-TK-715
291-PI-T-004
2220
FROM LOADED ORGANIC
SCRUB WATER PUMPS
291-PP-725/726
291-PI-T-013
2222
FROM ACID CRUD
COLLECTION PUMP
291-PP-738
291-PI-T-004
2215
TO SCRUB 1
PUMP MIX TANK
291-TK-722
291-PI-T-006
2216
TO RAFFINATE TANKS
291-TK-708/709
291-PI-T-010
2218
TO EXTRACTION CRUD
TANK
291-TK-738
291-PI-T-014
2467
TO 291-PP-725/726
291-PI-T-013
2469
FROM SCRUB AQUEOUS
METERING PUMP
291-MP-749
291-PI-T-006
2470
PLS FEED
FROM 291-FIC-0085
291-PI-T-003
2635
FROM SODIUM HYDROXIDE
METERING PUMP
284-MP-711
284-PI-T-006
2636
TO SODIUM HYDROXIDE
METERING PUMPS
284-MP-711/712
284-PI-T-006
SAMPLING
SAMPLING
NOTES:
1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001
2. AQUEOUS ADVANCE INTAKE THROUGH A STAND PIPE IN AQ WEIR.
3. VORTEX BREAKER LOCATED IN AQ RECYCLE INTAKE.
4. AQUEOUS RECLAIM DISCHARGE INTO SETTLER FEED LAUNDER.
5. SEE MECHANICAL DETAIL DRAWINGS FOR WEIR ACESS DETAILS.
LAH
LAL
DRAIN
LAHHTO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
( NOTE 3) ( NOTE 3)( NOTE 2)
(NOTE 4)
FDAH
FDAH
RATIO SP
RATIO SP
COLLECTION
WAND
(TYPICAL )
pH
pH
pH
pH
pH
pH
07-05-2012 8:56:13
FE
0130
+
291-TK-721
SCRUB 2
SETTLER TANK
291-TK-719
SCRUB 2 PUMP
MIX TANK
291-TK-718
SCRUB 1
SETTLER TANK
291-TK-717
SCRUB 1 AUXILIARY
MIX TANK
291-TK-716
SCRUB 1 PUMP
MIX TANK
291-AG-716
SCRUB 1 PUMP
MIX TANK
AGITATOR
291-TK-716
4"-LO-291-008-S1
NC
2"-ACC-291-001-S1
6"-LO-291-006-S1
2"-CSS-291-004-S1
2"-CSS-291-004-S1
6"-LO-291-006-S1
3"-SSS-291-026-S1
2"-LCD-291-044-S1
2"-ACC-291-003-S12"-ACC-291-003-S1
2"x1"
291-SA-013
291-SA-013
SCRUB RAFFINATE
SAMPLER
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
SCRUB
291-PI-T-005
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-005
MECHANICAL EQUIPMENT LIST REV. T000-EL-M-001
INSTRUMENTATION LEGEND P & ID
LOADED ORGANIC
291-PI-T-005
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
08/06/10
RC
JHL
MMB
ZDM
01/28/11DDDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND P & ID000-PI-T-001
4
2"-ACC-291-004-S1
SLOPE
291-AG-716
291-TK-717
291-AG-717
291-TK-718
291-TK-719
291-AG-719 291-TK-720
291-AG-720
291-TK-721
291-AG-720
SCRUB 2 AUXILIARY
MIX TANK
AGITATOR
291-AG-717
SCRUB 1 AUXILIARY
MIX TANK
AGITATOR
291-TK-720
SCRUB 2 AUXILIARY
MIX TANK
291-AG-719
SCRUB 2 PUMP
MIX TANK
AGITATOR
FE
0129
+
2" 2"
2"x1"
1/2"-A-37
NC
2"-A-15 2"-A-15
NC
2"-SPH-6A
6"-LO-291-003-S1
2"-CSS-291-004-S1
6"-SSS-291-028-S1
4"-LO-291-008-S1
2"-CSS-291-004-S1
6"-LO-291-010-S1
2"-ACC-291-004-S1
2"-A-15
6"-B-4-GO-E72
3"-B-4-GO
6"-B-4-GO
6"-B-4-GO-E72
4"-B-4-GO-E72 2"-A-15
2"-A-15
2"-A-15
3"-A-15
6"-B-4-GO
6"-B-4-GO
4"-A-15
4"-A-15
2"-A-15
6"-B-4-GO
2"-A-15
NC
NC
NC
NC
NC
NC
NC
NC
NC
2"-A-15
6"-B-4-GO
NC
NC
NC
NC
2"-A-15
NC
6"-LO-291-009-S1
6"-LO-291-004-S1
3"-SSS-291-026-S1
V
FE
0131
+
FE
0132
+
LVF1
LVF1
LVF1 LVF1
1"-A-15
NC
1"-A-15
NC
1"-C-10
2"-C-10
V
291-MX-701
291-MX-701
SODIUM HYDROXIDE
IN LINE MIXER
1"-A-15
2"-SH-291-016-S1
1"-CSS-291-001-S1
2"-LCD-291-037-S1
2"-C-10
6"-SSS-291-024-S1
2"-A-15
6"-B-4-GO-E72
2"-E-18
1"-SH-284-019-S1
1"-A-15
NC
1"-A-15
NC
4"-B-4-GO-E72
NC
2"-A-15
2"-C-10
2"-A-15
6"-B-4-GO-E72
1"-A-15
NC
2"-SPH-6A
4"-LO-291-005-S1
6"-SSS-291-024-S1
3"-SSS-291-026-S1
4"-LO-291-005-S1
2"-A-15
291-PP-738
291-PP-738
ACID CRUD
COLLECTION PUMP
2"-ACC-291-001-S1
2"x1"
2"x1"
6"x4"6"x4" 6"x4"6"x4"
SLOPE
6"-B-4-GO 6"-B-4-GO
NC 2"-A-15
NC
4
4
6. M
M
VFD
VFD
M
VSD
M M
0141
LIT
0141
LIC
0141
LE
LCS
PP747M
XU
LCS
I
I
PP748M
XU
I
S/D
I
0142
FIC
FAH
FAL
0142
FIT
0144
PIT
0144
PSHH
0145
PSHH
0145
PIT
0145
PI
0144
PI
0143
LG
2"
I MP749M
XU
LCS
I
0120
HIC
0142
HIC
M
0146
FI
0146
FI
0146
FIQ
VENT
2215
FROM SCRUB 2 SETTLER
291-TK-721
291-PI-T-005
2436
TO S-1 PUMP MIX TANK
291-TK-723
291-PI-T-011
2469
TO SCRUB 2
SETTLER TANK
291-TK-721
291-PI-T-005
2520
TO S-2 AQUEOUS ADVANCE PUMPS
291-PP-730/731
291-FIC-0169
291-PI-T-007
2519
W-1 AQUEOUS RECYCLE
291-FIC-0188
291-PI-T-008
2517
TO BARREN ORGANIC
WASH WATER PUMPS
291-PP-727/728
291-PI-T-013
2"
ISOTAINER LAHH
LAH
LAL
(STANDBY)
(NOTES 3 & 4)
2"-A-15
291-PP-795 291-PP-796
291-PP-795
REAGENT DRUM PUMP
291-PP-796
REAGENT DRUM PUMP
291-PP-747
LOADED ORGANIC
PUMP
291-PP-748
LOADED ORGANIC
PUMP
(STANDBY)
291-PP-794
291-PP-794
DILUENT PUMP
AND METERING SKID
1"-CSS-291-001-S1
2"-C-10
V
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
AFTER SETTLER TANK
291-PI-T-006
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-006
MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
INSTRUMENTATION LEGEND P & ID
LOADED ORGANIC
291-PI-T-006
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM/MKM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
4
FE
0146
+
1"-SPH-20 1"-SPH-20
3"-SPH-20
1"-A-15 1"-A-15
3"-A-15
08-05-2012 17:28:03
291-TK-747
291-TK-747
LOADED ORGANIC
AFTER SETTLER TANK
LVF1
NC
NC
6"-A-15
1"-A-15
1"-A-15
6"-A-15
291-PP-748
291-PP-747
FE
0142
+
3"-A-15
4"-A-15
NC
NC
4"-SPH-6A
3"-SPH-6A
NC
NC
6"-LO-291-010-S1
6"-B-4-GO
4"-A-151"-A-15
NC
6"-SLO-291-007-S1
6"-SLO-291-008-S1
6"-SLO-291-009-S1
6"-A-156"-C-23
1"-A-15
6"-A-15 6"-A-15
6"-A-15
6"-A-15
6"-A-15
1"-A-15
NC
NC
6"x4"
6"x4"
6"-C-23
1"-A-15
1"-A-15
NC
LVF1
1"-SPH-6A
1"-SPH-6A
1"-SPH-6A
1"-SPH-6A
1"-TAE-291-001-S1 1"-TAE-291-002-S1
3"-DIL-291-001-S1
291-PK-794
DILUENT PUMP AND
METERING SKID PACKAGE
LFF1
NC
1"-SPH-6A
1"-SPH-6A
NC
291-MP-749
291-MP-749
SCRUB AQUEOUS
METERING PUMP
4"-SPH-6A
NC
6"-SPJ-1H
6"-SPJ-1H
2"
2491
FROM BARREN ORGANC PUMPS
291-PP-733/734
291-FFIC-0186
291-PI-T-008
(NOTE 3)
(NOTE 2)
(NOTE 2)
291-PK-004
LOADED ORGANIC
PUMP
SKID PACKAGE
291-PK-004
1"-A-151"-C-10
1"-A-15
1"-CSS-291-005-S1
1"-CSS-291-005-S1
2"x1"
2"x1"
M
2"-TAE-291-003-S1
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. PUMPS START AUTOMATICALLY WITH BARREN ORGANIC PUMPS.
3. TANK IS DRAINED TO EXTRACTION CRUD SUMP (291-PP-721) VIA
CONDUCTIVE STAINLESS STEEL BRAIDED HOSE.
4. SCRUB AQUEOUS METERING PUMP SUCTION AND DRAIN NOZZELS
ARE LOCATED AT THE BOTTOM OF THE TANK.
5. ALL REAGENT CONTAINERS AND UNLOADING ELEMENTS NEED TO
BE BONDED AND GROUNDED.
6. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK TABLE.
I LCS
3"x1"
I
PP794M
XU
LFF1291-PK-794
3"-DIL-291-002-S1
3030
(VENDOR FOAM SYSTEM)
FROM SX PLANT
S/D INTERLOCK
S/D
(NOTE 6)
S/D
6"-SLO-291-006-S1
1-1/2"x1"
1-1/2"x1"
3"x1/2"
4
4
4
4
4
4
7. VFDVFD
M M
M
M
VFD
VFD
M
VFD
AG728M
XU
LCSI
0163
CI
CAL
LCS
LCS I PP730M
XU
LCS
0160
LI
LAH
LAL 0160
LE
I
M
M
0169
FIT
0169
FIC FAH
FAL
0169
HIC
0162
HIC
I
PP731M
XU
AG727M
XU
0165
CIT
LCS
0165
CE
I
0165
CI
CAL
0163
CIT
0163
CE
LCS I
0162
FIT
0162
FIC
0167
LE
0167
LIT
0167
LI
LAHH
LAL
0168
LIT
0168
LIC
LAHH
0168
LE
PP714M
XU
0167
LSHH
I
I
TM730M
XU
LCS
AG727M
SIC SAH
SAL AG728M
SIC SAH
SAL
TM730M
SIC SAH
SAL
0168
LSHH
0160
LIT
0167
LI
2386
FROM W-1 TANKS
291-PI-T-0082387
TO S-1 STRIP
291-PI-T-011
2389
FROM BARREN ORGANIC
WASH WATER PUMPS
291-PP-727/728
291-PI-T-013
2390
TO STRIP S-1 PUMP
MIX TANK
291-TK-723
291-PI-T-011
2396
FROM AQUA
AMMONIA PUMPS
291-PP-765/766
291-PI-T-011
2392
FROM W-1 AQUEOUS
ADVANCE PUMPS
291-PP-776/777
291-PI-T-008
2698
TO RAFFINATE TANK
291-DI-708
291-PI-T-010
2699
VIA COLLECTION DITCH
TO EMERGENCY POND
255-PD-001
255-PI-T-007
2394
TO STRIP CRUD
COLLECTION TANK
291-TK-737
291-PI-T-014
2399
TO WASH W-1 PUMP
MIXER TANK
291-TK-731
291-PI-T-008
2400
FROM STRIP S-1
CLARIFIER SETTLER TANK
291-TK-726
291-PI-T-011
2403
TO STRIP CRUD
COLLECTION TANK
291-TK-737 VIA
291-PI-T-0112417
FROM V-1 CLARIFIER
SETTLER TANK
291-TK-733
291-PI-T-008
2518
FROM 291-FIC-0262
291-PI-T-012
2520
FROM LOADED ORGANIC FLOW
291-FIC-0142
291-PI-T-006
TO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
LAH
(STANDBY)
NOTE:
1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001
LAH
LAL
LALL
DRAIN
FAH
FAL
M
291-TK-727
291-AG-728
291-PP-714
291-PP-714
SX STRIP
SUMP PUMP
3"-A-15 3"-A-15
3"-B-4
2"-A-15
4"-B-4-GO-E72
3"-RS-291-002-S1
4"-SBO-291-19971-S1
4"-AMS-291-025-S1
4"-PV-291-018-P1
3"-PV-291-019-P1
3"-PV-291-017-P1
3"-PV-291-016-P1
4"x2"4"x2"
1"-A-15
291-AG-727
S-2 PUMP MIX
AGITATOR
291-TK-727
S-2 PUMP
MIX TANK
291-AG-727
291-TK-728
291-TK-728
S-2 AUXILIARY
MIX TANK
291-AG-728
S-2 AUXILIARY MIX
AGITATOR
FE
0169
+
FE
0162
+
3"-AMS-291-008-S1
3"x2"
291-PK-005
291-PK-005
S-2 AQUEOUS
ADVANCE PUMP
SKID PACKAGE
6"-PV-291-015-P1
1"-LCD-291-005-S1
2"-AMC-291-001-S1
3"-PV-291-016-P1
4"-PV-291-018-P1
4"-A-15
4"-AMS-291-027-S1
3"-AMS-291-008-S1
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
S-2 STRIP
291-PI-T-007
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-007
MECHANICAL EQUIPMENT LIST, REV.T000-M-EL-001
INSTRUMENTATION LEGEND P & ID
291-PI-T-007
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM/MKM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P-& ID000-PI-T-001
4
4"-B-4-GO-E72
3"-B-11
3"-B-11
3"-B-11
4"-B-11
3"-B-11
NC
NC
NC
NC 4"-AMS-291-026-S1
3"-AMS-291-029-S1
FV
0262A
+
V6
LFF1
2"-AQA-291-059-S1
3"-AMS-291-036-S1
3"-AMS-291-037-S1
291-CO-714
291-CO-714
STRIP SUMP COVER
3"-SPH-6A
LVF1
LVF1
3"-C-23
3"-C-23
NC
NC
NC
NC
3"-A-15
1"-A-15
291-PP-730
1"-A-15
291-PP-731
1"-A-15
1"-A-15
3"-SPJ-1H
3"-SPJ-1H
3"-A-15
4"-A-15
3"x1-1/2"
4"x3"
3"x1-1/2"
4"x3"
32 CM
INSPECTION
FLANGE
291-TK-730
S-2 CLARIFIER
SETTLER TANK
291-TM-730
S-2 SETTLER
MECHANISM
291-PP-731
S-2 AQUEOUS
ADVANCE PUMP
(STANDBY)
291-PP-730
S-2 AQUEOUS
ADVANCE PUMP
291-TK-776
S-2 SETTLER
AQ OVERFLOW TANK
291-TK-730
291-TM-730
291-TK-776
FV
0162
+
6"-SBO-291-001-S1
2"-AMC-291-001-S1
2"-AMC-291-002-S1
2"-A-15
NC
2"-SPH-6A
2"-A-15
NC
2"-SPH-6A
6"-B-4-GO
6"-B-4-GO-E72
NC
2"-A-15
6"-SLO-291-010-S1
6"-B-4-GO-E72
6"-SLO-291-011-S1
3"-B-4-GO
NC
3"-B-4-GO
3"-AMS-291-028-S1
4"-A-15
07-05-2012 10:17:19
2"-A-15
2"-A-15
NC
NC
3"-C-23
SLOPE
3"-PV-291-014-P1
2" 2"
1"-A-15
NC
3"-SPH-6A
V6
LVF1 LVF1
LVF1
NC
291-MX-727
291-MX-727
S-2 NH3
INLINE MIXER
V6
4"-B-4-GO-E72
3"-AMS-291-005-S1
3"-AMS-291-020-S1
3"-A-153"-A-15
3"-A-15
NC
2"x1"
1"-A-15
NC
NC
NC
3"x2" 3"x2"
V
V
4
4
I I
I
I
I
8. M
VFD
M
M
M
VFD
M
M
M
VFD VFD
VFD
VFD
VFD
I
I
M
LCS
I
S/D
LCS
LCS
0188
FIT
0189
FIT
0183
LSHH
LCS
0181
CI
CAL
AG732M
XU
AG731M
XU
0181
CE
LCS
0186
HIC
M
0188
HIC
0186
FIT
0186
FIC
I PP733M
XU
I ILCS
PP734M
XU
I
I
I
LCS
I
I
PP777M
XU
0183
LIT
LCS
0183
LE
II
0187
FIC
0187
FIT
0187
FI
M
M
I
0188
FIC
FAH
FAL
0182
CE
0190
FIC
0189
FIC
0190
FIT
AG731M
SIC SAH
SAL
0184
LIC LAH
AG732M
SIC SAH
SAL
0184
LIT
PP776M
XU
0184
LE
0181
CIT
0182
CI
CAL
0182
CIT
0185
LIT
0185
LI
LAHH
0185
LSLL
LCS I
TM733M
SIC
SAL
SAH
I
TM733M
XU
0192
PIT
0192
PSHH
0191
PSHH
0191
PIT
0185
LSHH
0194
LG
0192
PI
0191
PI
0189
FI
2421
FROM STRIP CRUD SUMP PUMP
291-PP-722
291-PI-T-014
2386
TO S-2 STRIP
291-PI-T-007
2637
TO 291-FIC-0283
291-PI-T-013
2392
TO S-2 PUMP MIX TANK
291-TK-727
291-PI-T-007
3031
(VENDOR FOAM SYSTEM)
FROM SX PLANT S/D INTERLOCK
(NOTE 3)
2225
TO E-2 PUMP MIX TANK
291-TK-710
291-PI-T-004
2399
FROM S-2 CLARIFIER
SETTLER TANK
291-TK-730
291-PI-T-007
2417
TO STRIP CRUD
COLLECTION TANK VIA
291-TK-737
291-PI-T-007
2419
FROM BARREN ORGANIC
WASH WATER PUMPS
291-PP-727/728
291-PI-T-013
2426
FROM ORGANIC HOLDING
TANK PUMP
291-PP-741
291-PI-T-015
2462
FROM 291-FIC-0085
291-PI-T-003
2491
TO 291-FIC-0142 RATIO CONTROL
291-PI-T-006
2497
TO ORGANIC HOLDING TANK
PUMP 291-PP-741
291-PI-T-016
2519
FROM LOADED ORGANIC FLOW
291-FIC-0142
291-PI-T-006
2521
TO 291-FIC-0262 RATIO CONTROL
291-PI-T-012
2590
FROM PURIFICATION WASH
RETURN PUMPS
292-PP-780/781
292-PI-T-007
2638
TO 291-FIC-0283
291-PI-T-013
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. AQUEOUS RETURN FROM CRUD PLANT DISCHARGES
INTO SETTLER FEED LAUNDER.
3. TO BE SPECIFIED BT AKER SOLUTIONS INTERLACK TABLE.
(NOTE 2)
(STANDBY)
(STANDBY)
LAHH
LAH
LAL
S/D
LAL
LALL
LAH
PAHH
PAH
PAHH
PAH
LAHH
LAL
LALL
TO S/D
INTERLOCK
TO S/D
INTERLOCK
RSP
COLLECTION
WAND
S/D
S/D
FE
0190
+
NC
NC
3"-A-15
4"-A-15
2"-SPH-6A
3"-SPH-6A
6"-WBO-291-004-S1
4"-AMS-291-034-S1
3"-AMS-291-035-S1
3"-AMS-291-036-S1
4"-AMS-291-033-S1
291-PK-006
291-TK-731
WASH W-1 PUMP
MIXER TANK
291-AG-731
W-1 PUMP MIXER
TANK AGITATOR
291-TK-732
WASH W-1 AUXILIARY 1
MIXER TANK
291-AG-732
W-1 AUXILIARY MIXER
TANK AGITATOR
291-TK-733
W-1 CLARIFIER
SETTLER TANK
291-PP-737
AMMONIA CRUD
COLLECTION PUMP
291-TM-733
W-1 SETTLER
MECHANISM
291-TK-777
W-1 SETTLER
AQ OVERFLOW TANK
3"-AMS-291-043-S1
4"x2"4"x2"
1"-A-15
NC
4"-B-4-GO-E72
3"x2" 3"x2"
6"-WBO-291-002-S1
6"-WBO-291-003-S1
6"-WBO-291-001-S1
6"-WBO-291-004-S1
2"-LCD-291-045-S1
4"-PV-291-023-P1
HV
0197
+
HV
0198
+
V1ZV1Z
291-PK-007
2"-A-15
2"-A-15
NC
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
ORGANIC WASH
291-PI-T-008
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/05/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-008
MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
INSTRUMENTATION LEGEND P & ID
W-1
291-PI-T-008
02/03/11RCJHLDDZDMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM/MKM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
4
NC
3"-B-11
3"-B-11
4"-B-11
3"-B-11
3"-WBO-291-009-S1
2"-ACO-292-056-S1
3"-ABS-291-061-S1
2"-AMC-291-001-S1
2"-LCD-291-041-S1
4"-WBO-291-010-S1
6"-SBO-291-001-S1
2"-AMC-291-003-S1
6"-PV-291-020-P1
3"-AMS-291-036-S1
3"-PV-291-021-P1
3"-PV-291-022-P1
3"-PV-291-024-P1
291-TK-777
291-TM-733
291-TK-733291-TK-732
291-AG-731
LVF1
LVF1
4"x1-1/2"
6"-B-4-GO-E72
291-TK-731
291-AG-732
NC
291-PP-777
NC
NC
NC
1"-A-15
1"-A-15
1"-A-15
1"-A-15
1-1/2"-SPJ-1H
1-1/2"-SPJ-1H
2-1/2"x1"
4"x1-1/2"
2-1/2"x1"
2-1/2"-C-23
2-1/2"-C-23
FE
0188
+
291-PP-776
FE
0189
+
LVF1
LVF1
6"-SPJ-1H
6"-SPJ-1H
6"-C-23
6"-C-23
6"x4"
6"x4"
291-PP-733
1"-A-15
NC
1"-A-15
NC
1"-A-15
NC1"-A-15
NC
6"-A-15-GO
6"-A-15-GO
6"-A-15-GO
291-PP-734
V6
FV
0188
+
V6
FV
0187
+
FE
0186
+
V6 FV
0189
+
291-TK-734
6"-A-15-GO
2"-A-15
6"-B-4-GO-E72
4"-B-4-GO-E72
291-PP-737
3"-AMS-291-042-S1
6"-WBO-291-006-S1
2"-SPH-6A
2"-A-15
NC
3"-B-4
3"-A-15
1"-A-15
2"-A-15
2"x1/2" 2"x1/2"
2"-A-15
NC
NC
2"
2"
NC
4"-A-15
4"-B-4-GO
6"-B-4-GO
NC
1"-A-15
6"-A-15-GO
1"-A-15
2"-A-15
LVF1 LVF1
05-05-2012 10:50:11
NC
4"-AMS-291-038-S1
2"-A-15
4"-B-4-GO-E72
NC
NC
NC
2"-A-15
V1Z
V1Z
HV
0199
+
HV
200
+
FE
0187
+
3"-A-15
2"-A-15
NC
SLOPE
V
291-TK-734
BARREN ORGANIC
TANK
291-PP-733
BARREN ORGANIC
PUMP
291-PP-734
BARREN ORGANIC
PUMP
(STANDBY)
291-PK-006
BARREN ORGANIC
PUMP
SKID PACKAGE
291-PP-776
W-1 AQUEOUS
ADVANCE PUMP
291-PP-777
W-1 AQUEOUS
ADVANCE PUMP
(STANDBY)
291-PK-007
W-1 AUQEOUS
ADVANCE PUMP
SKID PACKAGE
2"x1/2"
2"x1/2"
3"-A-15
2"-A-15
2"-A-15
4
0183
LI
4
3"x2-1/2"
4
4
3"x2-1/2"
4 4
4
4
4
4
V
V
0183
LI
9. VFD
VFD
M
MM
LCS
PP751M
XU
ILCS
PP752M
XU
LCS I
I I
I
IPP743M
XU
I LCSI LCS
0201
LI LAHH
LALL 0201
LIT
0201
LE
0202
LIC LAHH
LALL
0202
LIT
0202
LE
0201
LSHL
0207
FIT
0207
FIC
0021
LI
0021
LAHL
PP759M
XU
0021
LIT
LCS I
I
0021
LE
2227
TO PURIFICATION SURGE
TANKS
292-TK-757/758
292-PI-T-001
1815
FROM PLANT AIR
DISTRIBUTION
265-PI-T-006
2743
TO PURIFICATION
SURGE TANKS
292-TK-757/758
292-PI-T-001
2744
TO P-1 PURFICATION TANK
292-TK-752
292-PI-T-002
2413
STRIP RICH
AQUEOUS PUMPS
291-PP-735/736
291-PI-T-011
NOTE:
1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001
M
3"-A-15
3"-A-15
3"-A-15
NC
NC
NC
3"-RS-291-024-S1
3"-RS-291-012-S1
3"-C-233"-PV-291-002-P1
291-ZM-735
291-ZM-735
STRIP ORGANIC
RECOVERY SPARGER
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
AND ORGANIC RECOVERY
291-PI-T-009
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/02/12RCMMBAPPOBM
09/14/11RCJHLJHLCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-009
MECHANICAL EQUIPMENT LIST R, REV. T000-EL-M-001
INSTRUMENTATION LEGEND & P & ID
SX AMMONIA SCRUBBER
291-PI-T-009
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM/MKM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
4
2"-A-15
1"-A-15
NC
1"-A-15 2"-A-15
4"-RS-291-004-S1
3"-RS-291-005-S1
3"-RS-291-011-S1
4"x3"
3"-SPJ-1H
3"-SPJ-1H
3"x1-1/2"
3"x1-1/2"
NC
4"x3"
4"-A-15
1"-A-15
1"-A-15
1"-A-15
NC
1"-A-15
NC 3"-A-15
3"-C-23
NC
3"-A-15
LVF1
LVF1
3"-C-23
3"-A-15
NC
NC
3"x1-1/2"
3"x1"
1"-A-15
1-1/2"-SPJ-1H
291-PP-743
291-PP-743
STRIP ORGANIC
RECOVERY PUMP
291-TK-735
STRIP RICH
AQUEOUS TANK
291-TK-735
291-PP-752
PURIFICATION
FEED PUMP
(STANDBY)
291-PP-751
PURIFICATION
FEED PUMP
291-PP-751
3"-RS-291-021-S1
3"-RS-291-016-S1
2"-RS-291-017-S1
3"-RS-291-015-S1
3"-RS-291-006-S1
4"-A-15
LVF1
3"-A-15
01-05-2012 12:51:27
NC
4"-A-15
2"-A-15
2"-C-10
FE
0207
+ FV
0207
+
V6 PCV
0210
+
291-PP-752
4"-PV-291-015-P1
NCNC
3"-SPH-6A
292-PP-759
LFF1
292-PP-759
PURIFICATION
SUBMERSIBLE
SUMP PUMP
2501
TO S-1 AUXILARY
MIX TANK LAUNDER
291-TK-724
291-PI-T-011
2432
TO STRIP CRUD TANK
291-TK-737
291-PI-T-014
3"-PD-291-031-P1
2" 2"
3"-B-11
3"-B-11
NC
3"-RS-291-011-S1
3"-PV-291-041-P13"-PV-291-041-P1
292-CO-759
292-CO-759
PURIFICATION
SUMP COVER
2429
TO AMMONIA VENT
291-PI-T-012
(STANDBY)
291-PK-015
4"-RS-291-003-S1
3"-RS-291-006-S1
291-PK-015
PURIFICATION
FEED PUMP
SKID PACKAGE
3001
TO COLLECTION DITCH
EMERGENCY POND
255-PD-001
255-PI-T-007
3"x2"
3"-PA-265-117-L8B
2"-PA-265-076-S1
3"x2"
3039
TO SX CRUD FILTER
291-FL-702
291-PI-T-015
3"-PA-265-117-L8B
4
10. VFD
VFD
M
M
VFD
M
0225
FIC
0225
FIT
0224
FIT
0221
LE
0222
LE
LAHH
LAH
I
I
0222
LIT0221
LIT
0224
FIC
FAL
0222
LIC
LAL
0221
LIC
LAL
0223
PIT
LCS
LCS
PP708M
XU
PP709M
XU
I
I
0226
FIC
0226
FIT
PP745M
XU
LCS
I
I
0223
PI
PAL
PAH
M
0227
LIC LAHH
0227
LE
0227
LIT
2698
FROM S-2 STRIP SUMP PUMP
291-PP-714
291-PI-T-007
2216
FROM SCRUB-1 SETTLER
291-TK-718
291-PI-T-005
2253
FROM SX EXTRACTION
SUMP PUMP
291-PP-710
291-PI-T-004
2434
TO E-2 SETTLER
291-TK-712
291-PI-T-004
2435
FROM E-2 SETTLER
291-TK-712
291-PI-T-004
2444
TO GYPSUM SEEDING TANK
285-TK-094
285-PI-T-020
2445
TO EXTRACTION CRUD
COLLECTION TANK
291-TK-738
291-PI-T-014
2447
FROM STRIP CRUD SUMP PUMP
291-PP-722
291-PI-T-014
2448
FROM EXTRACTION CRUD SUMP
PUMP 291-PP-721
291-PI-T-014
OVERFLOW
SAMPLING
30"
MH
LAH
LAHH
(NOTE 2)
(STANDBY)
3"-AMS-291-005-S1
LV
0222
+
4"-A-15
291-DI-708
291-DI-708
RAFFINATE
DIVERSION BOX
8"-ABS-291-005-S1
8"-ABS-291-006-S1
291-SA-012
6"-ABS-291-021-P7
291-SA-012
RAFFINATE
SAMPLER
3"-A-15
SLOPE
SLOPE
6"x4"
4"-A-16
4"-A-16
4"-C-22
4"-C-22
4"-A-164"-A-16
8"-B-4-GO 8"-B-4-GO
6"x4"
4"x3"
8"x4"
6"x3"
8"x4"
6"x3"
4"-A-15
3"-ASU-291-032-S1-HC
NC
6"-A-15A-GO 6"-A-15A-GO
4"-SPJ-1H
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
SYSTEM
291-PI-T-010
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/07/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-010MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
SOLVANT EXTRACTION FLOWSHEET291-FS-T-001
INSTRUMENTATION LEGEND, P&ID
SX RAFFINATE
291-PI-T-010
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND, P&ID000-PI-T-001
4
LV
0221
+
291-PP-709
291-PP-708
291-PP-709
RAFFINATE PUMP
(STANDBY)
291-PP-708
RAFFINATE PUMP
291-TK-709
RAFFINATE TANK
NC
291-TK-708
RAFFINATE TANK
FV
0225
+
291-TK-709
FE
0225
+
291-TK-708
NCNC
NC
NC
NC
NC
291-TK-745
RAFFINATE ORGANIC
RECOVERY TANK
291-TK-745
FE
0226
+
NC
NC 291-PP-745
291-PP-745
RAFFINATE ORGANIC
RECOVERY PUMP
8"-ABS-291-019-S1
8"-ABS-291-018-S1
4"-ABS-291-014-S1
4"-ABS-291-013-S1
6"-ABS-291-010-S1
3"-SSS-291-026-S1
4"-ABS-291-047-S1
3"-ABS-291-007-S1
8"-ABS-291-011-S1
8"-ABS-291-016-S1
2"-PA-291-151-L8B
6"-ABS-291-020-S1
8"-A-15A-GO
8"-A-15-GO8"-A-15-GO
1"-A-15
1"-A-15
6"-C-23
1"-A-15
8"-A-15-GO
1"-A-15 4"-SPJ-1H
6"-C-23 1"-A-15
8"-A-15-GO
1"-A-15
4"-SPJ-1H
4"-C-23 1"-A-15
4"-A-15
4"-ABS-291-031-S1
8"-B-4-GO8"-B-4-GO
4"-A-15
4"-A-15
2"-A-15
6"-A-15-GO
NC
SLOPE
6"-ABS-291-009-S1
2"
4"-A-15A
NC
4"-ABS-291-022-S1
09-05-2012 10:02:48
1"-SPH-6A
1"-SPH-6A
V6
V6
V6
LVF1
LVF1
LVF11"-SPH-6A
1"-SPH-6A
1"-SPH-6A
1"-SPH-6A
6"-A-15
3"-A-15
4"-A-15
4"-A-15
3"-A-15
3"-A-15
8"x4"
FE
0224
+
NC
PCV
0232
+
PCV
0231
+
V6
3"-A-15
3"-SU-288-023-P7
S1 P7
6"-ABS-291-009-S16"-ABS-291-015-S1
NOTES:
1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001.
2. RECOVERED ORGANIC PUMPED INTO THE E-2 SETTLER
FEED LAUNDER.
3. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK TABLE.
291-PK-008
291-PK-008
RAFFINATE PUMP
SKID PACKAGE
NC
8"-ABS-291-017-S1
8"-A-15-GO
8"-A-15-GO
8"-ABS-291-002-S18"-ABS-291-001-S1 8"-ABS-291-020-S1
6"-A-15-GO
6"-ABS-291-015-S1
291-PK-009
291-PK-009
RAFFINATE ORGANIC
RECOVERY PUMP
SKID PACKAGE
1932
FROM AMMONIA RECOVERY
SUMP PUMP
288-PP-430
288-PI-T-110
1828
FROM AMMONIA
SCRUBBER PUMPS
288-PP-233/234
288-PI-T-101
-HC
2430
TO AMMONIA SCRUBBER
288-DC-130
288-PI-T-101
2446
FROM HYDROMET PLANT
AIR RECEIVER
265-AR-009
265-PI-T-006
2"-PA-265-150-L8B
4"-ABS-291-013-S1
6"-ABS-291-012-S1
4"x2" 4"x2"
S/D
3032
(VENDOR FOAM SYSTEM)
FROM SX PLANT S/D INTERLOCK
(NOTE 3)
4"x3"
4"x3"
4"x3"
FV
0226
+
8"x6"
4
4
8"x6"4
4 4
4
4
4
4
11. VFD
M
M
M MM
VFD VFD
VFD
VFD
0246
FIT
0246
FIC FAH
FAL
M
0247
WI
0246
HS
I
I
I
0247
FIT
LCS
LCS
0241
CI
AG724M
XU
AG723M
XU
0241
CE
LCS I
I
LCS
0242
CE
0247
FI FAH
FAL
I
I
PP736M
XU
LAHH
0243
LIT
LCS
0243
LE
II
AG723M
SIC SAH
SAL
0244
LIC LAH
LAL
724M
SIC
SAH
SAL
0244
LIT
PP735M
XU
0244
LE
0241
CIT
0242
CI
CAH
0242
CIT
I
TM726M
XU
LCS
TM726M
SIC
SAL
SAH
I
0243
LSHH
C
0247
DI
0247
TI
2387
FROM S-2 STRIP TANKS
291-PI-T-007
2390
FROM S-2 AQUEOUS ADVANCE
PUMPS
291-PP-730/731
291-PI-T-007
2388
FROM AQUEOUS AMMONIA PUMPS
291-PP-765/766
291-PI-T-012 2396
TO S-2 PUMP MIX TANK
291-TK-727
291-PI-T-007
2501
FROM STRIP ORGANIC RECOVERY
PUMP 291-PP-743
291-PI-T-009
2412
TO TANK VENT COMPRESSOR
KNOCKOUT DRUM
288-VL-101
286-PI-T-008
2413
TO STRIP RICH
AQUEOUS TANK
291-TK-735
291-PI-T-009
2400
TO S-2 PUMP MIX TANK
291-TK-727
291-PI-T-007
2403
FROM AMMONIA CRUD COLLECTION
PUMP 291-PP-738
291-PI-T-007
2436
FROM LOADED ORGANIC PUMPS
291-PP-747/748
291-PI-T-006
2438
TO STRIP CRUD
COLLECTION TANK
291-TK-737
291-PI-T-014
2529
FROM 291-FIC-0262
291-PI-T-012
CAH
(STANDBY)
NOTE:
1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001.
2. RECOVERED ORGANIC DISCHARGES TO SETTLER
FEED LAUNDER.
LAH
LAL
DRAIN
TO SX PLANT
S/D INTERLOCK
TO SX PLANT
S/D INTERLOCK
SAMPLING
SAMPLING
(NOTE2)
32 CM INSPECTION
FLANGE
3"-SPH-6A
291-PP-735
291-PP-736
RICH AQUEOUS
PUMP
(STANDBY)
291-TM-726
S-1 SETTLER
MECHANISM
LVF1
LVF1
4"x3"
291-TK-726
STRIP S-1 CLARIFIER
SETTLER TANK
3"-A-15
FE
0247
+
6"-A-15
FE
0246
+
291-SA-014
291-SA-014
SETTLER
SAMPLER
1/2"-A-15
NC
NC
NC
3"-B-11 3"-B-114"-B-11 3"-B-11
3"x2" 3"x2"
NC
NC
4"x2"4"x2"
4"-B-4-GO
4"-RS-291-019-S1
4"-RS-291-018-S1
3"-RS-291-021-S1
3"-PV-291-028-P1
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
4"-AMS-291-050-S1
3"-AMS-291-030-S1
6"-SLO-291-009-S1
4"-SBO-291-003-S1
4"-SBO-291-003-S1
6"-SLO-291-010-S1
2"-AMC-291-053-S1
4"-AMS-291-050-S1
LVF1
LVF1 LVF1
3"-AMS-291-029-S1
3"-RS-291-016-S1
291-TK-723
291-AG-724
NC
291-PP-736
6"-B-4-GO-E72
NC
NCNC
3"-A-15
1"-A-15
1"-A-15
1"-A-151"-A-15
3"-SPJ-1H
3"-SPJ-1H
3"-A-15
4"-A-15 3"x1-1/2"
4"x3"
3"x1-1/2"
3"-C-23
3"-C-23
291-TK-775
291-AG-724
S-1 AUXILIARY MIXER
TANK AGITATOR
291-TM-726
291-TK-724
STRIP S-1 AUXILIARY
MIXER TANK
291-TK-726291-TK-724
291-TK-775
S-1 SETTLER
AQ OVERFLOW TANK
291-AG-723
291-PP-735
RICH AQUEOUS
PUMP
291-TK-723
STRIP S-1 PUMP
MIXER TANK
291-AG-723
S-1 PUMP MIXER
TANK AGITATOR
6"-SLO-291-010-S1
2"-AQA-291-059-S1
2"-AMC-291-001-S12"-AMC-291-001-S1
6"-SLO-291-009-S1
2"-AMC-291-053-S1
6"-PV-291-015-P1 6"-PV-291-015-P1
3"-PV-291-027-P1
3"-PV-291-028-P1
4"-PV-291-029-P1
3"-PV-291-030-P1
3"-A-15
2"-AQA-291-062-S1
3"-RS-291-020-S1
2"-A-15
4"-A-154"-A-15
2"-A-15
2"-A-15
2"-A-15
2"-A-15
4"-B-4-GO-E72
NC
3"-A-15 3"-A-15
3"-B-4
3"-RS-291-023-S1
3"-RS-291-022-S1
6"-B-4-GO
NC
FV
0262B
+
FV
0246
+
4"-B-4-GO-E72
SLOPE
NCNC
V6
04-05-2012 11:54:02
V6
2"-C-10
NC
1"-A-15
NC
291-MX-723
291-MX-723
S-1 NH3
INLINE MIXER
4"-B-4-GO-E72
NC
NC
1"-A-15
2"-SPH-6A
S-1 STRIP
291-PI-T-011
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/02/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/30/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & RE-ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-011
MECHANICAL EQUIPMENT LIST, REV. T000-M-EL-001
INSTRUMENTATION LEGEND P & ID
291-PI-T-011
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
01/28/11
RC
JHL
MMB
ZDM/MKM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
4
2" 2"
3"-RS-291-021-S1
291-PK-010
291-PK-010
STRIP RICH
AQUEOUS PUMP
SKID PACKAGE
0243
LI
0243
LI
V
V
4
4
4
12. M
VFD
M
VFD
M
0765
TE
0765
TIT
0765
TI TAHH
TAH
0262
HIC
I
ILCS
PP766M
XU
LCS
PP765M
XU
I
I
0262
FIT
0262
FIC
LCS
PP767M
XU
I
I
0260
LIT
0260
LI LAH
C
C
0261
FIC
0261
FIT
0261
DIC
0260
LSHH
0263
TIT
0263
TE
0263
TI
1938
FROM ANHYDROUS AMMONIA
ISOTAINERS
289-PI-T-001
2388
TO S-1 PUMP MIX TANK
291-TK-723
291-PI-T-011
1794
FROM CAUSTIC BOIL
DISTILLATE COOLER
298-HX-115
288-PI-T-105
1796
FROM AMMONIA ABSORBER
BOTTOMS COOLER
288-CK-200
288-PI-T-106
2956
TO TANK VENT COMPRESSOR
KNOCKOUT DRUM VIA
6"-PV-292-025-P1
292-PI-T-003
2625
TO PURIFICATION AMMONIA
WASSH BOOSTER TANK
292-TK-764
292-PI-T-004
2429
FROM STRIP RICH
AQUEOUS TANK
291-TK-735
291-PI-T-009
2505
FROM AMMONIA STRIPPER
DISTILLATE COOLER
288-HX-112
288-PI-T-112
2507
FROM AMMONIA CONDENSATE
ADVANCE PUMPS
292-PP-783/784
292-PI-T-004
2518
TO 291-FV-0262A
291-PI-T-007
2521
FROM 291-FIC-0186
291-PI-T-008
2529
TO 291-FV-0262B
291-PI-T-011
(STANDBY)
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
LAL
S1
4"-PV-291-015-P1
4"-A-8
291-PV-701
291-PV-701
AQUA AMMONIA
STORAGE VESSEL
1-1/2"-AQA-291-058-S1
08-05-2012 10:16:47
3"-AQA-291-058-S1
3"-AQA-291-060-S1
2"-AQA-291-061-S1
2"-AQA-291-059-S13"-AQA-291-058-S1
2"-AQA-291-059-S1
NC
NC
NC
4"-PV-291-015-P1
4"-PV-291-010-P1
1/2"-AQA-291-007-S1
2"-A-5
2"-C-5
1-1/2"-C-10
1"-C-5
1-1/2"-C-5
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
AMMONIA SUPPLY
07/07/11TO 291-PI-T-012
291-SOLVENT EXTRACTION
P & ID
5 05/05/12RCMMBAPPOBMUPDATED AND RE-ISSUED FOR CONSTRUCTION
4
3
2
B
1
0
08/26/11RCJHLMMBCAC
07/20/11RCJHLMMBCAC
07/07/11RCJHLJHLMKM
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION
UPDATED & RE-ISSUED FOR CONSTRUCTION
REVISED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-012
MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
INSTRUMENTATION LEGEND P&ID
AQUEOUS
291-PI-T-012
02/03/11RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/20/11
07/20/11
07/20/11
12/11/10
RC
JHL
MMB
ZDM/EAD
01/28/11DDDDZDMISSUED FOR INTERNAL REVIEWPIPING LEGEND P&ID000-PI-T-001
5
1"-SPH-6A 1"-SPH-6A
291-PP-766
3"-A-15
1"-A-15
NC
NC
2"x1"
2"-C-10
NC
1"-A-15
2"-A-15
291-PP-765
NC
NC
1"-A-152"-C-10
1"-A-15
2"x1"
3"-A-15
2"-A-15
2"-AQA-291-059-S1
291-PP-767
NC NC
1"-A-152"x1-1/2" 1-1/2"-C-10
1"-A-152"-A-15
1-1/2"-A-15
291-MX-702
3"-A-15
1-1/2"-A-15
DV
0261
+
291-PP-767
AQUA AMMONIA
RECYCLE PUMP
291-PP-765
AQUA AMMONIA
PUMP
291-PP-766
AQUA AMMONIA
PUMP
(STANDBY)
291-MX-702
AMMONIA
IN-LINE MIXER
2"-AQA-288-050-L6
2"-AHA-289-006-A3
1-1/2"-ACO-292-051-S1
1"-AQA-288-052-L6
1-1/2"-AQA-288-005-L6
2"-E-4
FE
0262
+
LFF1
LVF1
LVF1
FE
0261
+
2"-A-5
2"-A-5
4"-A-85
1/2"-A-15
PSV
0264
+
V6
1"-SPH-6A
1"-SPH-6A
1"-SPH-6A
1"-SPH-6A
291-PK-011
291-PK-011
AQUEOUS AMMONIA
PUMP
SKID PACKAGE
1-1/2"-AQA-291-056-S1
1-1/2"-AQA-291-056-S1
2"-AQA-291-055-S1
291-PK-014
291-PK-014
AQUEOUS AMMONIA
RECYCLE PUMP
SKID PACKAGE
2"-AHA-289-006-A3
4"-AMV-291-030-P1
4"-B-11
L6
3077
TO CALCINER VENT
KNOCKOUT DRUM
288-VL-103
287-PI-T-005
5
1-1/2"x1"
5
5
3"x2"
3"x2"
5
5
5
5
13. VFD
M
M
M
VFD
VFD
M
VFD
2"
2"
0281
LIC
LAL
LAH
PP725M
XU
0281
LE
LCS
0281
LIT
I I
I
PP727M
XU
I
0283
FIC
I
PP728M
XU
0283
FIT
M
I LCS
LCS
PP726M
XU
I I LCS
0281
LSL
0283
HIC
0284
LI
0281
LSLL
0130
HIC
2389
TO S-2 SETTLER AQUEOUS
OVERFLOW TANK
291-TK-776
291-PI-T-007
2637
FROM 291-FI-0189
291-PI-T-008
2220
TO SCRUB 1 PUMP MIX TANK
291-TK-716
291-PI-T-005
2419
WASH W-1 PUMP MIXER TANK
291-TK-731
291-PI-T-008
2467
FLOW CONTROL 291-FIC-0130
291-PI-T-005
2517
FROM 291-FIC-0142
291-PI-T-006
2585
FROM STRIPPER BOTTOMS
WATER ADVANCE PUMPS
292-PP-778/779
292-PI-T-006
2638
FROM 291-FI-0187
291-PI-T-008
TO FLOOR
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK TABLE,
000-LT-I-205, AT A LATER DATE.
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
2"-A-15 2"-A-15
2"-A-15
NC
WATER TANK
291-PI-T-013
291-SOLVENT EXTRACTION
P & ID
4
3
2
B
1
0
05/07/12RCMMBAPPOBM
08/26/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
04/04/11RCJHLDDMKM
03/10/11RCJHLDDMKM
A
REVISED AS NOTED
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
UPDATED & ISSUED FOR CONSTRUCTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CONSTRUCTION
000-PI-T-002
560-291-PI-T-012MECHANICAL EQUIPMENT LIST, REV. T000-EL-M-001
SX RO WATER, CAUSTIC, & AMMONIA SUPPLY FLOWSHEET291-FS-T-002
INSTRUMENTATION LEGEND P&ID
SX WASH & SCRUB
291-PI-T-013
02/03/04RCJHLDDMKMISSUED FOR CLIENT APPROVAL
07/19/11
07/19/11
07/19/11
12/13/10
RC
JHL
MMB
ZDM
01/28/11DDDDZDMISSUED FOR REVIEWPIPING LEGEND P&ID000-PI-T-001
4
NC
NC
NC
NC
291-PP-725
LOADED ORGANIC
SCRUB WATER PUMP
291-PP-726
LOADED ORGANIC
SCRUB WATER PUMP
(STANDBY)
291-PP-727
BARREN ORGANIC
WASH WATER PUMP
291-PP-728
BARREN ORGANIC
WASH WATER PUMP
(STANDBY)
291-PP-725
291-TK-742
6"-PD-291-008-P1
24"
MANHOLE
2"-A-15A3"-A-15A
1"-A-15
NC
2"x1-1/2"
1"-A-15
2"x1"
LVF1
NC
NC
2"-C-10
2"-A-15A
291-PP-726
1"-A-15
NC
2"x1"
1"-A-152"-C-10
NC
2"x1-1/2"
LVF1
2"-A-15
2"-A-15
2"-A-15
2"-A-15
2"-LCD-291-040-S1
2"-LCD-291-038-S1
2"-LCD-291-039-S1
2"-LCD-291-041-S1
2"-LCD-291-037-S1
291-PP-727
2"-LCD-291-022-S1
2"-LCD-291-043-S1
291-PP-728
2"-A-151"-A-15
NC
2"-A-15
2"x1"
2"-C-10
NC
2"-C-10
NC
LVF1
LVF1
NC
2"x1"
2"-A-15
2"-A-15
1"-A-15
1"-A-15
1"-A-15
291-TK-742
SX WATER
TANK
FE
0283
+
2"-LCD-292-032-S1
1"-LCD-291-005-S1
1"-A-15
02-05-2012 12:01:55
LV
0281 A
+
4"
2"x1/2"2"x1/2"
2515
FROM RO UTILITY WATER
PUMPS
280-PP-009/010
280-PI-T-003
2"-RO-280-002-S1
LV
0281 B
+
V1Z
FC
3"
(STANDBY)
(STANDBY)
291-PK-013
2"-LCD-291-041-S1
2"-LCD-291-041-S1
2"-LCD-291-040-S1
2"-LCD-291-037-S1
2"-LCD-291-036-S1
291-PK-012
291-PK-012
BARREN ORGANIC
SCRUB WATER PUMP
SKID PACKAGE
291-PK-013
LOADED ORGANIC
SCRUB WATER PUMP
SKID PACKAGE
S/D
S/D
S/D
S/D
3033
(VENDOR FOAM SYSTEM)
FROM SX PLANT S/D INTERLOCK
(NOTE 2)
S/D
4
4
4
4
4
14. M M
M
M
M
LCS
0305
LI
0305
LIT
0305
LE
0305
LAHL
I
PP721M
XU
I
0306
LE
LCS
I
I
0306
LIT
PP722M
XU
0306
LAHL
0306
LI
0302
LSLL
0302
LSLLAH
0302
LI
I
LCS
I
I
PP719M
XU
I
PP720M
XU
LCS
0301
LE
RADAR
0301
LIT
0302
LIT
0302
LE
RADAR
II
AG738M
XU
LCS
I
I
AG736M
XU
0301
LI
LAH
0301
LSLL
0301
LSL
0033
LG 0034
LG
2878
FROM ORGANIC
HOLDING TANK PUMP
291-PP-741
291-PI-T-015
2421
TO W-1 CLARIFIER
SETTLER TANK
291-PI-T-008
2218
FROM ACID CRUD
COLLECTION PUMPS
291-PP-738
291-PI-T-005
2252
FROM SX EXTRACTION
SUMP PUMP
291-PP-710
291-PI-T-004
2394
FROM SX STRIP
SUMP PUMP
291-PP-714
291-PI-T-007
2432
FROM STRIP ORGANIC
RECOVERY PUMP
291-PP-743
291-PI-T-009
2438
FROM AMMONIA CRUD
COLLECTION PUMP
291-PP-737
291-PI-T-011
2445
FROM RAFFINATE
ORGANIC RECOVERY PUMP
291-PP-745
291-PI-T-010
2447
TO RAFFINATE DIVERSION BOX
291-DI-708
291-PI-T-010
2448
TO RAFFINATE
DIVERSION BOX
291-DI-708
291-PI-T-010
2702
TO SX CRUD FILTER
291-FL-702
291-PI-T-015
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001
CLAY ADDITION
BY HAND
CLAY ADDITION
BY HAND
4" OVERFLOW4" OVERFLOW
02-05-2012 14:24:11
2"-A-15
3"-ABS-291-052-S1
2"-ABS-291-053-S1
4"-ABS-291-24133-S1
3"-A-15
4"-A-15
3"-A-15
3"-A-15
NC
2"-C-10
2"-C-10
2"-A-15
2"-A-15
NC
3"-A-15
3"-A-15
2"-ABS-291-055-S1
2"-ABS-291-060-S1
3"-ABS-291-054-S1
STRIP CRUD TANKS
07/25/11RBR/TO 291-PI-T-014
291-SOLVENT EXTRACTION
P & ID
1
B
0
C
05/07/12RCMMBAPPOBM
09/14/11RCJHLMMBCAC
07/19/11RCJHLMMBCAC
A
ISSUED FOR CONSTRUCTION.
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CLIENT APPROVAL
000-PI-T-002
560-291-014
MECHANICAL EQUIPMENT LIST, REV. U000-EL-M-001
INSTRUMENTATION LEGEND P & ID
ORGANIC TREATMENT
291-PI-T-014
04/14/11RCJHLDDMKMISSUED FOR APPROVAL
07/19/11
07/19/11
07/19/11
07/27/10
RC
JHL
MMB
MKM
04/04/11RCJHLDDMKMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
1
NC
NC
3"-PV-291-012-P1
NC
2"-A-15
2"-A-15
LFF1
LFF1
LFF1
LFF1
LFF1
LFF1
3"-PV-291-011-P1
2"-A-15
2"-WBO-291-014-S1
3"-WBO-291-011-S1
2"-WBO-291-012-S1
291-CO-722
291-CO-722
STRIP CRUD
SUMP COVER
NC
1"-A-15
2"-A-15
2"-A-15
1"-A-15
NC
NC
NC
NC
2"-A-15
NC
3"-A-15
4"-A-15
3"-A-15
3"-SPJ-1H
3"-SPJ-1H
2"-A-152"-A-15
NC NC
2"-A-15
NC
291-CH-737291-CH-738
291-CH-738
STRIP CRUD
CLAY ADDITION CHUTE
291-CH-737
STRIP CRUD
CLAY ADDITION CHUTE
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EM BODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
4"-PD-291-032-P1
4"-PD-291-033-P1
291-TK-738
291-TK-738
EXTRACTION CRUD
COLLECTION TANK
3"-AMS-291-008-S1
2"-RS-291-017-S1
3"-A-153"-A-15
4"-ABS-291-24133-S1
4"-ABS-291-047-S1
3"-ABS-291-061-S1
4"-ABS-291-24133-S1
4"-ABS-291-014-S1
2"-ACC-291-001-S1
3"-ACC-291-020-S1
2"-AMC-291-001-S1
291-PP-720
291-PP-720
STRIP CRUD
FILTER FEED PUMP
291-PP-719
291-PP-719
EXTRACTION CRUD
FILTER FEED PUMP
291-TK-737
291-TK-737
STRIP CRUD
COLLECTION TANK
291-AG-737
291-AG-738
291-AG-738
EXTRACTION CRUD
TANK AGITATOR
291-AG-737
STRIP CRUD
TANK AGITATOR
291-PP-721
291-PP-721
EXTRACTION CRUD
SUBMERSIBLE SUMP PUMP
3"-ABS-291-059-S1
3"-ABS-291-057-S1
2"-ABS-291-058-S1
2"-ABS-291-049-S1
2"-WBO-291-013-S1
4"-C-23
4"-C-10
2"-A-15
2"-A-15
2"-A-15
2"-A-15
2"-ABS-291-046-S1
3"-ABS-291-051-S1
3"-ABS-291-056-S1
2"-ABS-291-032-S1
3"-B-11 3"-B-11
2217
FROM ORGANIC HOLDING TANK
291-TK-741
291-PI-T-015
2951
FROM ORGANIC HOLDING TANK
291-TK-741
291-PI-T-015
M
4"-SPH-6A
291-PP-722
4"-SPH-6A
291-PP-722
STRIP CRUD
SUBMERSIBLE SUMP PUMP
2"-WBO-291-014-S1
2"-ABS-291-060-S1
3"-PV-291-012-P1
2"-ABS-291-029-S1
3"-WBO-291-011-S1
2"-AMC-291-001-S1
3"-AMS-291-008-S1
2"-RS-291-017-S1
2"-WBO-291-013-S1
LCS
3"-A-15
2"-A-15
8"-PV-291-025-P1
2705
TO PURIFICATION TANKS
292-TK-752/755
292-PI-T-002
4"x3"
4"x2"
4"x2"
2"-ABS-291-048-S1
1
1
1
1
1
1
1
1
1
1
1
1 1
15. M M
M
LCS I
PP723M
XU
I I
PP741M
XU
LCSI
I
AG740M
XU
ILCS
0321
LE
0321
LIT
0321
LI
0321
LSLL
0322
LIT
0322
LI
0322
LE
0322
LSLL
0320
PI
0320
PIT
2878
TO CRUD TANKS
291-TK-737/738
291-PI-T-014
2951
TO EXTRACTION CRUD
COLLECTION TANK
291-TK-738
291-PI-T-014
3039
FROM PLANT AIR
DISTRIBUTION
291-PI-T-009
2217
TO STRIP CRUD
COLLECTION TANK
291-TK-737
291-PI-T-014
2426
TO BARREN
ORGANIC TANK
291-TK-734
291-PI-T-008
2702
FROM STRIP CRUD FILTER
FEED PUMP
291-PP-720
291-PI-T-014
NOTES:
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. REMOVABLE CART.
3. OPEN/CLOSE HAND SWITCH WITH INDICATION GAUGES.
DE
BY HAND
COLLECTION
3"-A-15 3"-A-15
NCNC
3"-A-153"-A-15A
291-CH-740
3"-A-15
3"-WBO-291-007-S1
3"x1-1/2"
2"-WBO-291-014-S1
2"x1/2"
1"x3/8"
1"-A-15
2"-PA-265-116-S1
3/8"-PA-291-128-S1
NOTICER E F E R E N C E S
TOROMOCHO PROJECT
C-560 REVISION
DWG. NO.
AREA
CAD NO.
MINERA CHINALCO PERU S.A.
TITLE
AREA
PROJECT
SIGN AND STAMP
SIGN
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
NAME
DOCUMENT CONTROL
DISCIPLINE MANAGER NAME
QUALITY CONTROL
A1
SHEET SIZE
DATE :
DATE :
DATE :
DATE :
DATE :DRAWN BY:
CHECKED BY:
APPROVED BY:
AUTHORIZED BY:
MCP APPROVED:
SCALE :
THIS IS A COMPUTER GENERATED DRAWING. ALL
CHANGES HERE TO SHALL BE PERFORMED USING
CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY
UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
WRITTEN PERMISSION.
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
DATEAPPROVEDCHECKBYDESCRIPTIONNO.
R E V I S I O N S
THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN
T I T L EDWG. NO.
NC
1"-A-15 NC
1"-A-15
09-05-2012 10:19:11
2"-PA-291-162-S1
2"-A-15
LFF1
291-PP-723
2"-C-23
NC
291-AG-740
1-1/2"-SPJ-1H1"-A-15
NC
1"-A-15
291-TK-740 291-TK-741
LFF1
291-PP-741
2"-WBO-291-001-S1
2"-A-15
2"-A-15
3"x2"
3"-DRIP TRAY
3"-PD-291-012-P1
3"-PD-291-006-P1
3"-ASL-291-004-S1
3"-WBO-291-009-S1
2"-A-15
2"-A-15
CRUD FILTER
07/25/11RBR/TO 291-PI-T-015
291-SOLVENT EXTRACTION
P & ID
1
B
0
C
05/07/12RCMMBAPPOBM
09/14/11RCJHLJHLCAC
07/19/11RCJHLMMBCAC
A
ISSUED FOR CONSTRUCTION.
UPDATED AND RE-ISSUED FOR CONSTRUCTION.
ISSUED FOR CLIENT APPROVAL
000-PI-T-002
560-291-015
MECHANICAL EQUIPMENT LIST, REV. U000-EL-M-001
INSTRUMENTATION LEGEND P & ID
ORGANIC TREATMENT
291-PI-T-015
04/22/11RCJHLDDZDMISSUED FOR APPROVAL
07/19/11
07/19/11
07/19/11
03/10/11
RC
JHL
MMB
MKM
04/14/11RCJHLDDMKMISSUED FOR REVIEWPIPING LEGEND P & ID000-PI-T-001
1
3"-A-15A
NC
2"-A-15
2"-A-15
2"-WBO-291-008-S1
2"-PA-291-065-S1
3"-SPJ-1H
3"-WBO-291-011-S1
2"x1"
LFF1
2"-A-15
2"-A-15
291-ZM-702
2"-A-15
NC
NC
3"-PA-291-117-L8B3"-PA-291-117-L8B
3"x2"
3"x2"
2"-ABS-291-058-S1
3"-C-22
3"-A-15
2"-WBO-291-001-S1
2"-WBO-291-013-S1
2"x1-1/2" 2"x1-1/2"
(NOTE 3)
2"-ABS-291-058-S1
2"-ABS-291-035-S1
2"-PA-291-162-S1
2"-ABS-291-037-S1
2"-ABS-291-033-S1
2"-PA-291-163-S1
2"-ABS-291-058-S1
2"-ASL-291-005-S1
2"-ASL-291-005-S1
2"-ABS-291-037-S1
2"-ABS-291-036-S1
2"-ABS-291-038-S1
VENDOR
PACKAGE
V
V
V
V
V V
V
V
VV
291-FL-702
(NOTE 2)
2"-ABS-291-038-S1
2"-ABS-291-036-S1
2"-ABS-291-040-S1
2"-ABS-291-034-S1
2"-PA-291-064-S1
2"-ABS-291-041-S1
2"-ABS-291-042-S1
291-FL-702
SX CRUD FILTER
291-ZM-702
CRUD FILTER
CAKE PAN
291-TK-740
SX CRUD FILTER
PRECOAT TANK
291-AG-740
SX CRUD FILTER
PRECOAT TANK
AGITATOR
291-PP-723
SX CRUD FILTER
PRECOAT PUMP
291-TK-741
ORGANIC HOLDING
TANK
291-PP-741
ORGANIC HOLDING
TANK PUMP
V
3/8"
FNPT
CONN.
1323
HS
1323
ZO
1323
ZC
CLOSE OPEN
291-CH-740
CRUD FILTER
PRECOAT D.E.
ADDITION CHUTE
3"x1-1/2"
1
1