In this paper, different voltage injection schemes for dynamic voltage restorers (DVRs) are analyzed with particular focus on a new method used to minimize the rating of the voltage source converter (VSC) used in DVR. A new control technique is proposed to control the capacitor-supported DVR. The control of a DVR is demonstrated with a reduced-rating VSC. The reference load voltage is estimated using the unit vectors. The synchronous reference frame theory is used for the conversion of voltages from rotating vectors to the stationary frame. The compensation of the voltage sag, swell, and harmonics is demonstrated using a reduced-rating DVR.
Power quality problems such as transients, sags, swells, and other distortions to the sinusoidal waveform of the supply voltage affect the performance of these equipment pieces. Technologies such as custom power devices are emerged to provide protection against power quality problems. Custom power devices are mainly of three categories such as series-connected compensators known as dynamic voltage restorers (DVRs), shunt-connected compensators such as distribution static compensators, and a combination of series and shunt-connected compensators known as unified power quality conditioner. The DVR can regulate the load voltage from the problems such as sag, swell, and harmonics in the supply voltages. Hence, it can protect the critical consumer loads from tripping and consequent losses . The custom power devices are developed and installed at consumer point to meet the power quality standards such as IEEE-519 .
Voltage sags in an electrical grid are not always possible to avoid because of the finite clearing time of the faults that cause the voltage sags and the propagation of sags from the
Transmission and distribution systems to the low-voltage loads. Voltage sags are the common reasons for interruption in production plants and for end-user equipment malfunctions in general. In particular, tripping of equipment in a production line can cause production interruption and significant costs due to loss of production. One solution to this problem is to make the equipment itself more tolerant to sags, either by intelligent control or by storing “ride-through” energy in the equipment. An alternative solution, instead of modifying each component in a plant to be tolerant against voltage sags, is to install a plant wide uninterruptible power supply system for longer power interruptions or a DVR on the incoming supply to mitigate voltage sags for shorter periods [8]–[23]. DVRs can eliminate most of the sags and minimize the risk of load tripping for very deep sags, but their main drawbacks are their standby losses, the equipment cost, and also the protection
Scheme required for downstream short circuits.
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Control of dvr with a bess
1. UNDER THE GUIDNESS OF
Mr. J.VasanthKumar., M.Tech Asst.professor
Department of EEE
BY USING BESS THE COMPENSATION OF VOLTAGE
SAG&SWELL CAN BE CONTROLLED BY DVR
PRESENTED BY
K. Krishna reddy 14C25A0219
D. Swapna 14C25A0206
G. Ramu 13C21A0209
G. Rajashekar 13C21A0208
2. INTRODUCTION:
• POWER QUALITY problems in the present-day
distribution systems are due to the increased use of
sensitive and critical equipment pieces .
• Series-connected compensators known as dynamic voltage
restorers (DVRs)
3. DYNAMIC VOLTAGE RESTORER:
• The basic principle of a DVR is simple, by supplying a
voltage of desired magnitude and frequency, the DVR
restores the load voltage to a desired pre-sag voltage
quantity even when source voltage is not balanced.
CIRCUIT DIAGRAM :
4. BASIC CONFIGURATIONS OF DVR:
The general configuration of the DVR consists of:
• An Injection transformer
• Filter circuit
• A Voltage Source Converter
• A Control and Protection system
5. VOLTAGE SAG:
• Description: A decrease of the normal voltage level
between 10% and 90% of the nominal RMS voltage at the
power frequency, for durations of 0.5 cycle to 1 minute.
6. .
Voltage sag Consequences:
• Malfunction of microprocessor-based control systems(PCs,
PLCs, etc.)
• Tripping of contactors and relays.
• Disconnection and loss of efficiency in rotating machines.
• Dimming of lighting system.
8. VOLTAGE SWELL:
• Description: Swell can be defined as, “An increase to
between 80% and 180% in rms voltage or current at the
power frequency durations from 0.5 to 1 minute
9. Voltage swell Consequences:
• Data loss, flickering of lighting and screen.
• stoppage or damage of sensitive equipment if the voltage
values are too high.
• Production rates fluctuates.
• Variable speed drives close down to prevent damage.
12. DYNAMIC PERFORMANCE OF DVR WITH IN-PHASE INJECTION DURING
VOLTAGE SAG AND SWELL APPLIED TO CRITICAL LOAD
13. ADVANTAGES:
• It is less expensive
• Small in size
• Better power effective device as compare to other links
UPS,SMES,DSTATCOM.
• Fast response
• Less Maintenances
15. LIMITATIONS:
• DVR, the energy storage size of DVR is kept low.
• DVR has a limited current conduction and voltage
injection capability.
16. FUTURE SCOPE:
• Study and control of power quality issues for deregulated
power system.
• Soft computing techniques developed can be further used
in various fields of power system like – power system
dynamics & stability, smart grid, power system state
estimation, economic dispatch and optimal power flow.
17. CONCLUSION:
The operation of a DVR has been demonstrated with a
new control technique using various voltage injection
schemes. A comparison of the performance of the DVR
with different schemes has been performed with a reduced-
rating VSC, including a capacitor-supported DVR. The
SRF theory has been used for estimating the reference
DVR voltages. It is concluded that the voltage injection in-
phase with the PCC voltage results in minimum rating of
DVR but at the cost of an energy source at its dc bus.
18. REFERENCES:
• M. H. J. Bollen, Understanding Power Quality Problems—Voltage Sags
and Interruptions. New York, NY, USA: IEEE Press, 2000.
• A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom
Power Devices. London, U.K.: Kluwer, 2002.
• M. H. J. Bollen and I. Gu, Signal Processing of Power Quality
Disturbances. Hoboken, NJ, USA: Wiley-IEEE Press, 2006.
• IEEE Recommended Practices and Recommendations for Harmonics
Control in Electric Power Systems, IEEE Std. 519, 1992.
• M. Vilathgamuwa, R. Perera, S. Choi, and K. Tseng, “Control of energy
optimized dynamic voltage restorer,” in Proc. IEEE IECON, 1999, vol. 2,
pp. 873–878.
• J. G. Nielsen and F. Blaabjerg, “A detailed comparison of system
topologies for dynamic voltage restorers,” IEEE Trans. Ind. Appl., vol.
41, no. 5,pp. 1272–1280, Sep./Oct. 2005.