Global Scenario On Sustainable and Resilient Coconut Industry by Dr. Jelfina...
Hoxter Ecka 51/51/51L
1. 1
ECKA 51/51/51L Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
Operation when directly connected to chimney Cupola Hot air exchanger
Tested according to EN 13229 EN 13229
Nominal heat power 7 kW 10 kW
Efficiency > 80 % > 80 %
Consumption of wood 2,2 kg/h 3 kg/h
Mass flow of flue gas 6,4 g/s 9,6 g/s
Average flue gas temperature
on the output 254 °C 269 °C
Heat distribution
fireplace insert
door glass (single / double)
64–75 %
36 / 25 %
64–75 %
36 / 25 %
Required chimney pressure 12 Pa 12 Pa
Required amount of combustion air 30 m3
/h 35 m3
/h
Minimum supply air grating cross-section 650 cm2
950 cm2
Minimum outgoing air grating cross-section 800 cm2
1 150 cm2
General technical information
Combustion air connection Ø 125 mm
Total weight / lining weight ca. 186 / 67 kg
Use in non-ventilated accumulation builds according to craft rules suitable
Meets values BImSchV (Stufe2), 15a BVG
Operation with connected accumulation mass Cupola Adaptor
Load of wood 5 kg 5 kg
Total heat output of the burning chamber 19 kW 19 kW
Mass flow of flue gas 15 g/s 15 g/s
Average flue gas temperature
on the output 1)
past 3,2 m of ceramic accumulation system KMS 300 2)
past set of HOXTER accumulation rings
394 °C
178 °C
–
404 °C
–
235 °C
Heat distribution
fireplace insert
door glass (single / double)
adjoining accumulation mass
36 %
36 / 25 %
29–39 %
33 %
36 / 25 %
32–42 %
Required chimney pressure 12 Pa 12 Pa
Minimum radiant area 3)
ca. 4,5 m2
ca. 4,5 m2
Required amount of combustion air 50 m3
/h 50 m3
/h
1) The Hoxter products are available in the Austrian stove-calculation program for evaluation of firebrick accumulation systems.
2) Only a sample calculation! For accurate results is evaluation of each system in the KMS-calculation program from the Ortner company necessary.
3) Depends on accumulation period and material characteristics and its thickness. Calculated with heat emission of the radiant area ca. 500 W/m2
.hr
3. 3
M 1 : 10
ECKA 51/51/51L
1:1045-55
952
992
500 500
3
550
500
500
560
50
O
300
E
1:10
500 500
337
550
500
50
O
300
O125
1:10
45-55
952
992
500 500
3
550
500
500
560
50
O
300
Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
With adaptor
4. 4
M 1 : 10
ECKA 51/51/51L
1:10
45-55
952
1455
500 500
550
500
560
200O
O
457
1384
ECK1:10
45-55
500 500
550
500
200O
O125
457
1384
Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
With hot air exchanger
5. 5
M 1 : 10
45-55
550
500
500
560
50
200O
ECKA 51/51/51L Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
With hot air exchanger
6. 6
M 1 : 10
1:10
45-55
952
1339
500 500
550
500
500
560
50
200O
33
1:10
45-55
952
1339
500 500
550
500
500
560
50
200O
33
ECKA 51/51/5
1:10
45-55
500 500
550
500
500
50
200O
337
O125
ECKA 51/51/51L Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
With hot air exchanger vertical
7. 7
M 1 : 10
ECKA 51/51/51L
A
1:1045-55
530 530
530
530
590
80
580
ANBAURAHMEN
1:10
530 530
530
80 80
55
580
A
1:10
45-55
530 530
530
530
590
80
580
Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
Build-on frame 6-sided, 80 mm
8. 8
M 1 : 10M 1 : 10
ECKA 51/51/51L B
1:10
45-55
506 506
510
510
570
58 - 62
560
60
260497
B
1:10
45-55
506 506
510
510
570
58 - 62
560
60
260497
BLENDRAHMEN E
1:10
506 506
510
58 - 62
35
560
Technical data
Version 07/2017
Hoxter gmbh I Hersbrucker Straße 23 I 912 44 Reichenschwand I Germany I info@hoxter.de I +49 (0)9151 8659 163
Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
cover frame 6-sided, 60 mm