Findings from the Communications
Cable & Connectivity Association
(CCCA) Investigation into Suspected
Non-compliant Data Cable Imported
into the North American (NA) Market

       IWCS Charlotte 2009
CCCA Mission

 To serve as the major resource for well-researched,
 fact-based information on the technologies and
 products of Structured Cabling media to support
 current and future needs of the Networking, IT, and
 communications industries. CCCA will also be
 proactive at codes and standards bodies and other
 trade, industry and governmental organizations in
 communicating and influencing policy and decisions
 affecting the quality, performance and societal needs
 of the structured cabling infrastructure.


                                                         2
CCCA Membership

ADC                      3M Dyneon
Accu-Tech                General Cable
AlphaGary*               OCC
Anixter*                 OFS
Belden                   PolyOne
Berk-Tek                 Sentinel Connector
Cable Components Group   Systems
CommScope*               Solvay Solexis
Daikin America           Superior Essex*
DuPont                   Tyco Electronics*

                         * Executive Committee


          www.cccassoc.org
                                                 3
CCCA Program Objectives

• Independent quality assessment of lesser known
  brands of offshore UTP communications cables
  imported into the NA market

• Listed and verified as compliant to NA fire codes and
  industry standards for electrical performance.

• Share findings to improve QA procedures to prevent
  and/or uncover non - compliant cable in NA market.

• Provide education and create awareness on
  potential hazards of non compliant cable.



                                                          4
Cable Samples - Round 1 – 1Q 2008
• 9 samples … 4pr. UTP … all manufactured
  in Asia. Purchased at random from NA
  distributors
• Brand names generally considered
  “unknown” in North America.
• All had mark of one or more independent
  testing organizations – listed to NFPA
  codes - verified to TIA standards.
• Mix of Category 5e and 6 - CMR (riser) and
  CMP (plenum)
• Tested by major independent testing
  organization
                                               5
Summary of Test Results – Round 1

• All 9 failed physical requirements (TIA 568-B
  and UL 444)
• 4 of the 9 failed to meet minimum electrical
  requirements (TIA 568-B)
• 4 out of 5 CMR (riser) cables failed the UL
  1666 flame test. Many serious failures.
   – All 4 failing cables burned the entire length
      of the test chamber
   – The worst performing cable burned
      beyond the maximum length allowed in
      only 45 seconds and reached a
      temperature of 2000°F
                                                 6
Summary of Test Results – Round 1

• All 4 CMP (plenum) cables failed NFPA 262

   – All 4 samples showed peak smoke levels
     3-4X higher than maximum allowable
     levels
   – Average smoke levels were >3X higher
     than maximum allowable levels
   – The worst performing cable had extreme
     failure. Flame spread travelled length of
     the chamber within 6 minutes


                                                 7
Conclusions – Round 1
• Some manufacturers may be evading QA controls by
  submitting properly designed cable to a listing
  agency. After approval, substitute lower cost
  materials to improve profit.
• CCCA materials testing confirms this.
• QA procedures circumvented at point of manufacture
  and need to be improved. Emphasis on field
  sampling of finished cable.
• Practice threatens cabling industry
• Extreme failures raise serious fire safety concerns.
• Failure to meet physical and electrical performance
  minimums can slow network speeds and may result
  in network failures, lost productivity.
                                                         8
Cable Samples - Round 2 - 3Q 2009
• New set of 8 samples, all manufactured in Asia
• 5 of 8 cables from manufacturers who failed in 2008
• All samples from distribution (March-May ’09)
• All had quality mark of one or more independent
  testing organizations – listed to NFPA codes -
  verified to TIA electrical performance standards.
•     Mix of Category 5e and 6, CMR (riser) and CMP
     (plenum)
•    Cables analyzed for material composition
• Fire tests by major independent testing organization
• Electrical tests by UL audited test lab


                                                         9
Summary of Test Results – Round 2
• 7 of 8 cable samples failed
• 4 of the 5 samples from manufacturers from
  2008 failed fire safety.
   – 2 of the 4 CMR (riser) cables failed UL
     1666 flame test. Failed cables burned
     entire length of test chamber, reaching
     temperatures of almost 1000°F.
   –    All 4 plenum samples failed to meet
       maximum allowed smoke, up to 4X peak
       smoke.
• 2 of the 3 “new” manufacturers failed fire test
                                                    10
11
12
13
Conclusions

• Sub-standard, non-compliant cables still in
  inventory and being imported into the NA
  market.
• Some manufacturers still appear to be
  circumventing QA procedures at point of
  manufacture.
• Public safety remains a major unresolved
  concern.
• An effective QA process must include
  sampling of finished cable procured from
  field.
                                                14
UL Mark for Telecommunications
                     Cable

            Presented by: Steven Galan




Copyright© 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion of this material may be reprinted
in any form without the express written permission of Underwriters Laboratories Inc. or as otherwise provided in writing.
Agenda

•   Introduction
•   Market Surveillance Program
•   “Fingerprinting” of Extruded Product
•   Holographic Labeling
•   Next Steps




                                           p/ 2
Introduction
• UL Reviews Follow-up Programs on a
                     p    g
  regular basis
  – FUS Data
  – Field Data
• Recently conducted reviews were very
  successful
  –DDecorative Li hti
            ti Lighting
  – Flexible Cord
• Global Telecom Cable Program Review
  Conducted
                                         p/ 3
Market Surveillance Program

• Permanent Part of FUS Program
• Elements will be put in place which will
  allow for a wider range of sample
  selection
• Screening of small lengths of cable prior
  to conducting LSFT



                                              p/ 4
“Fingerprinting” of Extruded Products
 Fingerprinting

• Covers Plenum, Riser and Vertical Tray
• G
  Groupings of constructions to develop a
        i     f    t ti      t d    l
  test matrix




                                            p/ 5
Holographic Labeling

• Introduced for all Telecom Cables
  Categories
• High Level of Security
    g                   y
• Replaces paper Labels




                                      p/ 6
Next Steps

• Issue Bulletin to Industry
  – D t il E h It
    Detail Each Item
  – Time Line for Implementation
• Schedule and Hold Industry Forums
• Continue to Review Program




                                      p/ 7
Thank You




Copyright© 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion of this material may be reprinted
in any form without the express written permission of Underwriters Laboratories Inc. or as otherwise provided in writing.

More Related Content

What's hot

Presentation trvx cdmo-v2
Presentation trvx   cdmo-v2Presentation trvx   cdmo-v2
Presentation trvx cdmo-v2targovax2017
 
Case Study: Multi Category Sourcing in China, India, Vietnam and Turkey
Case Study: Multi Category Sourcing in China, India, Vietnam and TurkeyCase Study: Multi Category Sourcing in China, India, Vietnam and Turkey
Case Study: Multi Category Sourcing in China, India, Vietnam and TurkeyJohn William
 
Merix Def Aero Oct08 A
Merix Def Aero Oct08 AMerix Def Aero Oct08 A
Merix Def Aero Oct08 Aguest41dd72
 
Radio Frequency Test Stands for Remote Controllers
Radio Frequency Test Stands for Remote ControllersRadio Frequency Test Stands for Remote Controllers
Radio Frequency Test Stands for Remote ControllersUjjal Dutt, PMP
 
AS5553 New Standard - Zulueta
AS5553  New Standard - ZuluetaAS5553  New Standard - Zulueta
AS5553 New Standard - Zuluetapzulueta
 
SEM Test Development Center
SEM Test Development CenterSEM Test Development Center
SEM Test Development CenterESA Italia Srl
 
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...MilliporeSigma
 

What's hot (8)

Presentation trvx cdmo-v2
Presentation trvx   cdmo-v2Presentation trvx   cdmo-v2
Presentation trvx cdmo-v2
 
Case Study: Multi Category Sourcing in China, India, Vietnam and Turkey
Case Study: Multi Category Sourcing in China, India, Vietnam and TurkeyCase Study: Multi Category Sourcing in China, India, Vietnam and Turkey
Case Study: Multi Category Sourcing in China, India, Vietnam and Turkey
 
Asian creation introduction
Asian creation introductionAsian creation introduction
Asian creation introduction
 
Merix Def Aero Oct08 A
Merix Def Aero Oct08 AMerix Def Aero Oct08 A
Merix Def Aero Oct08 A
 
Radio Frequency Test Stands for Remote Controllers
Radio Frequency Test Stands for Remote ControllersRadio Frequency Test Stands for Remote Controllers
Radio Frequency Test Stands for Remote Controllers
 
AS5553 New Standard - Zulueta
AS5553  New Standard - ZuluetaAS5553  New Standard - Zulueta
AS5553 New Standard - Zulueta
 
SEM Test Development Center
SEM Test Development CenterSEM Test Development Center
SEM Test Development Center
 
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...
Modern BioManufacturing: Single-Use Technologies in Configurable, Prefabricat...
 

Viewers also liked (20)

GreenFormat in Practice: How Manufacturers and Designers Communicate About Pr...
GreenFormat in Practice: How Manufacturers and Designers Communicate About Pr...GreenFormat in Practice: How Manufacturers and Designers Communicate About Pr...
GreenFormat in Practice: How Manufacturers and Designers Communicate About Pr...
 
Vicky
VickyVicky
Vicky
 
Mercedes
MercedesMercedes
Mercedes
 
Comp
CompComp
Comp
 
Marieta
MarietaMarieta
Marieta
 
Manuel fernandez
Manuel fernandezManuel fernandez
Manuel fernandez
 
Vicky
VickyVicky
Vicky
 
Englishforthegames
EnglishforthegamesEnglishforthegames
Englishforthegames
 
Nahuel
NahuelNahuel
Nahuel
 
By cesar
By cesarBy cesar
By cesar
 
Ezequiel
EzequielEzequiel
Ezequiel
 
Celina
CelinaCelina
Celina
 
Martina
MartinaMartina
Martina
 
Manuel beloso
Manuel belosoManuel beloso
Manuel beloso
 
Lourdes
LourdesLourdes
Lourdes
 
Manuel cano
Manuel canoManuel cano
Manuel cano
 
Juana
JuanaJuana
Juana
 
Javier
JavierJavier
Javier
 
By cesar
By cesarBy cesar
By cesar
 
We are going on a bear hunt
We are going on a bear huntWe are going on a bear hunt
We are going on a bear hunt
 

Similar to CCCA and UL Presentation at IWCS2009

SIRIM Testing and Certification on Electrical Cable Testing
SIRIM Testing and Certification on Electrical Cable TestingSIRIM Testing and Certification on Electrical Cable Testing
SIRIM Testing and Certification on Electrical Cable TestingAhmadFauziHussin
 
Industrial Ethernet, Part 1: Technologies
Industrial Ethernet, Part 1: TechnologiesIndustrial Ethernet, Part 1: Technologies
Industrial Ethernet, Part 1: TechnologiesControlEng
 
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄС
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄСДіяльність щодо оптимізації ланцюга постачань ядерної галузі ЄС
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄСUkrainian Nuclear Society
 
Industry Standards and How They Impact Cable Assembly Designs
Industry Standards and How They Impact Cable Assembly DesignsIndustry Standards and How They Impact Cable Assembly Designs
Industry Standards and How They Impact Cable Assembly DesignsEpec Engineered Technologies
 
Arizona State University Test Lecture
Arizona State University Test LectureArizona State University Test Lecture
Arizona State University Test LecturePete Sarson, PH.D
 
Lithium Ion Abuse Test Methods Improvement [Presentation Slides]
Lithium Ion Abuse Test Methods Improvement [Presentation Slides] Lithium Ion Abuse Test Methods Improvement [Presentation Slides]
Lithium Ion Abuse Test Methods Improvement [Presentation Slides] TÜV SÜD America
 
Prepare Your Products for Successful Wireless Device EMC Testing
Prepare Your Products for Successful Wireless Device EMC TestingPrepare Your Products for Successful Wireless Device EMC Testing
Prepare Your Products for Successful Wireless Device EMC TestingNorthwest EMC
 
OIF Interop: The Key to Unlocking the Benefits of SDN
OIF Interop: The Key to Unlocking the Benefits of SDNOIF Interop: The Key to Unlocking the Benefits of SDN
OIF Interop: The Key to Unlocking the Benefits of SDNDeborah Porchivina
 
Industral Bus, Field Bus health test with scm125 b
Industral Bus, Field Bus health test with scm125 bIndustral Bus, Field Bus health test with scm125 b
Industral Bus, Field Bus health test with scm125 bZhaoyi Fang
 
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...adil raja
 
Category 6 Patch Cord Performance
Category 6 Patch Cord PerformanceCategory 6 Patch Cord Performance
Category 6 Patch Cord PerformanceShelley Mason
 
NAI-Interconnect-Solutions-PPT-E_cmp.pptx
NAI-Interconnect-Solutions-PPT-E_cmp.pptxNAI-Interconnect-Solutions-PPT-E_cmp.pptx
NAI-Interconnect-Solutions-PPT-E_cmp.pptxssusera85eeb1
 
Passive Intermodulation Test Methods - IEC Recommendations 2012
Passive Intermodulation Test Methods - IEC Recommendations 2012Passive Intermodulation Test Methods - IEC Recommendations 2012
Passive Intermodulation Test Methods - IEC Recommendations 2012Kaelus
 
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016Luis Antonio González Mederos
 
Internet2: VoIP Phone Codec Testing White Paper
Internet2: VoIP Phone Codec Testing White PaperInternet2: VoIP Phone Codec Testing White Paper
Internet2: VoIP Phone Codec Testing White PaperJoshua Reola
 
Battery Pack Development Timeline and Expectations
Battery Pack Development Timeline and ExpectationsBattery Pack Development Timeline and Expectations
Battery Pack Development Timeline and ExpectationsEpec Engineered Technologies
 
POC To Product: 8 Key Processes in Design Path
POC To Product: 8 Key Processes in Design PathPOC To Product: 8 Key Processes in Design Path
POC To Product: 8 Key Processes in Design Pathfuturewardcentral
 
Martin binnendijk - Session 1: Network Components
Martin binnendijk - Session 1: Network ComponentsMartin binnendijk - Session 1: Network Components
Martin binnendijk - Session 1: Network ComponentsDutch Power
 

Similar to CCCA and UL Presentation at IWCS2009 (20)

SIRIM Testing and Certification on Electrical Cable Testing
SIRIM Testing and Certification on Electrical Cable TestingSIRIM Testing and Certification on Electrical Cable Testing
SIRIM Testing and Certification on Electrical Cable Testing
 
Industrial Ethernet, Part 1: Technologies
Industrial Ethernet, Part 1: TechnologiesIndustrial Ethernet, Part 1: Technologies
Industrial Ethernet, Part 1: Technologies
 
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄС
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄСДіяльність щодо оптимізації ланцюга постачань ядерної галузі ЄС
Діяльність щодо оптимізації ланцюга постачань ядерної галузі ЄС
 
Industry Standards and How They Impact Cable Assembly Designs
Industry Standards and How They Impact Cable Assembly DesignsIndustry Standards and How They Impact Cable Assembly Designs
Industry Standards and How They Impact Cable Assembly Designs
 
Arizona State University Test Lecture
Arizona State University Test LectureArizona State University Test Lecture
Arizona State University Test Lecture
 
Lithium Ion Abuse Test Methods Improvement [Presentation Slides]
Lithium Ion Abuse Test Methods Improvement [Presentation Slides] Lithium Ion Abuse Test Methods Improvement [Presentation Slides]
Lithium Ion Abuse Test Methods Improvement [Presentation Slides]
 
Prepare Your Products for Successful Wireless Device EMC Testing
Prepare Your Products for Successful Wireless Device EMC TestingPrepare Your Products for Successful Wireless Device EMC Testing
Prepare Your Products for Successful Wireless Device EMC Testing
 
OIF Interop: The Key to Unlocking the Benefits of SDN
OIF Interop: The Key to Unlocking the Benefits of SDNOIF Interop: The Key to Unlocking the Benefits of SDN
OIF Interop: The Key to Unlocking the Benefits of SDN
 
EWS Resume 2016
EWS Resume 2016EWS Resume 2016
EWS Resume 2016
 
Industral Bus, Field Bus health test with scm125 b
Industral Bus, Field Bus health test with scm125 bIndustral Bus, Field Bus health test with scm125 b
Industral Bus, Field Bus health test with scm125 b
 
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...
Implementation of a Non-Intrusive Speech Quality Assessment Tool on a Mid-Net...
 
Category 6 Patch Cord Performance
Category 6 Patch Cord PerformanceCategory 6 Patch Cord Performance
Category 6 Patch Cord Performance
 
Khaled elhag cv
Khaled elhag cvKhaled elhag cv
Khaled elhag cv
 
NAI-Interconnect-Solutions-PPT-E_cmp.pptx
NAI-Interconnect-Solutions-PPT-E_cmp.pptxNAI-Interconnect-Solutions-PPT-E_cmp.pptx
NAI-Interconnect-Solutions-PPT-E_cmp.pptx
 
Passive Intermodulation Test Methods - IEC Recommendations 2012
Passive Intermodulation Test Methods - IEC Recommendations 2012Passive Intermodulation Test Methods - IEC Recommendations 2012
Passive Intermodulation Test Methods - IEC Recommendations 2012
 
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016
{A1fad7c7 d7c8-4772-8e67-3a934e1341ca} wp027007-en_fin_oct2016
 
Internet2: VoIP Phone Codec Testing White Paper
Internet2: VoIP Phone Codec Testing White PaperInternet2: VoIP Phone Codec Testing White Paper
Internet2: VoIP Phone Codec Testing White Paper
 
Battery Pack Development Timeline and Expectations
Battery Pack Development Timeline and ExpectationsBattery Pack Development Timeline and Expectations
Battery Pack Development Timeline and Expectations
 
POC To Product: 8 Key Processes in Design Path
POC To Product: 8 Key Processes in Design PathPOC To Product: 8 Key Processes in Design Path
POC To Product: 8 Key Processes in Design Path
 
Martin binnendijk - Session 1: Network Components
Martin binnendijk - Session 1: Network ComponentsMartin binnendijk - Session 1: Network Components
Martin binnendijk - Session 1: Network Components
 

CCCA and UL Presentation at IWCS2009

  • 1. Findings from the Communications Cable & Connectivity Association (CCCA) Investigation into Suspected Non-compliant Data Cable Imported into the North American (NA) Market IWCS Charlotte 2009
  • 2. CCCA Mission To serve as the major resource for well-researched, fact-based information on the technologies and products of Structured Cabling media to support current and future needs of the Networking, IT, and communications industries. CCCA will also be proactive at codes and standards bodies and other trade, industry and governmental organizations in communicating and influencing policy and decisions affecting the quality, performance and societal needs of the structured cabling infrastructure. 2
  • 3. CCCA Membership ADC 3M Dyneon Accu-Tech General Cable AlphaGary* OCC Anixter* OFS Belden PolyOne Berk-Tek Sentinel Connector Cable Components Group Systems CommScope* Solvay Solexis Daikin America Superior Essex* DuPont Tyco Electronics* * Executive Committee www.cccassoc.org 3
  • 4. CCCA Program Objectives • Independent quality assessment of lesser known brands of offshore UTP communications cables imported into the NA market • Listed and verified as compliant to NA fire codes and industry standards for electrical performance. • Share findings to improve QA procedures to prevent and/or uncover non - compliant cable in NA market. • Provide education and create awareness on potential hazards of non compliant cable. 4
  • 5. Cable Samples - Round 1 – 1Q 2008 • 9 samples … 4pr. UTP … all manufactured in Asia. Purchased at random from NA distributors • Brand names generally considered “unknown” in North America. • All had mark of one or more independent testing organizations – listed to NFPA codes - verified to TIA standards. • Mix of Category 5e and 6 - CMR (riser) and CMP (plenum) • Tested by major independent testing organization 5
  • 6. Summary of Test Results – Round 1 • All 9 failed physical requirements (TIA 568-B and UL 444) • 4 of the 9 failed to meet minimum electrical requirements (TIA 568-B) • 4 out of 5 CMR (riser) cables failed the UL 1666 flame test. Many serious failures. – All 4 failing cables burned the entire length of the test chamber – The worst performing cable burned beyond the maximum length allowed in only 45 seconds and reached a temperature of 2000°F 6
  • 7. Summary of Test Results – Round 1 • All 4 CMP (plenum) cables failed NFPA 262 – All 4 samples showed peak smoke levels 3-4X higher than maximum allowable levels – Average smoke levels were >3X higher than maximum allowable levels – The worst performing cable had extreme failure. Flame spread travelled length of the chamber within 6 minutes 7
  • 8. Conclusions – Round 1 • Some manufacturers may be evading QA controls by submitting properly designed cable to a listing agency. After approval, substitute lower cost materials to improve profit. • CCCA materials testing confirms this. • QA procedures circumvented at point of manufacture and need to be improved. Emphasis on field sampling of finished cable. • Practice threatens cabling industry • Extreme failures raise serious fire safety concerns. • Failure to meet physical and electrical performance minimums can slow network speeds and may result in network failures, lost productivity. 8
  • 9. Cable Samples - Round 2 - 3Q 2009 • New set of 8 samples, all manufactured in Asia • 5 of 8 cables from manufacturers who failed in 2008 • All samples from distribution (March-May ’09) • All had quality mark of one or more independent testing organizations – listed to NFPA codes - verified to TIA electrical performance standards. • Mix of Category 5e and 6, CMR (riser) and CMP (plenum) • Cables analyzed for material composition • Fire tests by major independent testing organization • Electrical tests by UL audited test lab 9
  • 10. Summary of Test Results – Round 2 • 7 of 8 cable samples failed • 4 of the 5 samples from manufacturers from 2008 failed fire safety. – 2 of the 4 CMR (riser) cables failed UL 1666 flame test. Failed cables burned entire length of test chamber, reaching temperatures of almost 1000°F. – All 4 plenum samples failed to meet maximum allowed smoke, up to 4X peak smoke. • 2 of the 3 “new” manufacturers failed fire test 10
  • 11. 11
  • 12. 12
  • 13. 13
  • 14. Conclusions • Sub-standard, non-compliant cables still in inventory and being imported into the NA market. • Some manufacturers still appear to be circumventing QA procedures at point of manufacture. • Public safety remains a major unresolved concern. • An effective QA process must include sampling of finished cable procured from field. 14
  • 15. UL Mark for Telecommunications Cable Presented by: Steven Galan Copyright© 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion of this material may be reprinted in any form without the express written permission of Underwriters Laboratories Inc. or as otherwise provided in writing.
  • 16. Agenda • Introduction • Market Surveillance Program • “Fingerprinting” of Extruded Product • Holographic Labeling • Next Steps p/ 2
  • 17. Introduction • UL Reviews Follow-up Programs on a p g regular basis – FUS Data – Field Data • Recently conducted reviews were very successful –DDecorative Li hti ti Lighting – Flexible Cord • Global Telecom Cable Program Review Conducted p/ 3
  • 18. Market Surveillance Program • Permanent Part of FUS Program • Elements will be put in place which will allow for a wider range of sample selection • Screening of small lengths of cable prior to conducting LSFT p/ 4
  • 19. “Fingerprinting” of Extruded Products Fingerprinting • Covers Plenum, Riser and Vertical Tray • G Groupings of constructions to develop a i f t ti t d l test matrix p/ 5
  • 20. Holographic Labeling • Introduced for all Telecom Cables Categories • High Level of Security g y • Replaces paper Labels p/ 6
  • 21. Next Steps • Issue Bulletin to Industry – D t il E h It Detail Each Item – Time Line for Implementation • Schedule and Hold Industry Forums • Continue to Review Program p/ 7
  • 22. Thank You Copyright© 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion of this material may be reprinted in any form without the express written permission of Underwriters Laboratories Inc. or as otherwise provided in writing.