SlideShare a Scribd company logo
1 of 8
Download to read offline
1
ADVANCES IN DYNAMIC FOUNDATION TESTING TECHNOLOGY
Garland Likins, P.E., MASCE 1
Ingemar Hermansson2
, Mike Kightley3
, Jon Cannon4
,
and David Klingberg5
1
President, Pile Dynamics, Inc., 4535 Renaissance Parkway, Cleveland OH 44128, USA; ph: 216-831-
6131; fax: 216-831-0916; email: garland@pile.com
2
Partner, Palanalys, August Barks Gata 13C, 421 32 Vastra, Frolunda, Sweden; ph: 46 31-45 43 07;
fax: 46 31-45 99 80; email: ingemar@palanalys.se
3
Managing Director, Testing and Analysis Ltd, Birchwood Way, Somercotes, Alfreton Derbyshire
DE55 4QQ UK; ph: 44-1773-540880; fax: 44-1773-540760; email: mike.kightley@testal.co.uk
4
Managing Director, Independent GeoSciences, 2 Letchworth Avenue, Brighton East, Victoria 3187,
Australia; ph: 61 3 9553-8288; fax: 61 3 9553-8288; email: indgeo@optushome.com.au
5
Piletest Manager, Wagstaff Piling, 1 Ashgrove Crescent, Brisbane, 4060 Queensland, Australia, ph:
61-7 3366 2555; fax: 61-7 3366 5608; email: d.klingberg@wagsttaffpiling.com.au
ABSTRACT: While dynamic pile testing is not new, and is included in many
worldwide codes and specifications, dramatic changes from traditional testing
methods and common practice have occurred in recent years.
Traditionally, the sensors send their signals through a cable to the data acquisition
equipment. Experience has shown that some poor data is caused by damage to or
fatigue of these cables. New equipment now transmits sensor data from the pile
wirelessly by Bluetooth to receiving antennas on the data collection equipment.
“Wireless” technology eliminates the cables and improves data quality. Sensors
which remember their calibration sensitivity and transmit that information eliminate
another common problem in data quality, namely having the wrong calibration
assigned. Methods of protecting the sensors during installation allow attaching
sensors prior to lifting the pile into the hammer leads, and hence speeding up the
testing process, and promote safety.
The most radical change in the data acquisition process is “remote” dynamic
testing, which has revolutionized dynamic testing in some parts of the world. In
remote testing, the data acquisition equipment is operated on site by an inspector or
the pile crew, and sends the data over the internet to the test engineer in his office.
The wireless and remote procedures are described and example experiences
indicate the great benefits, and areas of caution, of the new technology.
INTRODUCTION
Dynamic pile testing is not new. The original research began over 50 years ago at
Case Western Reserve University (Eiber, 1958). Dynamic testing with the Pile
2
Driving Analyzer®
(PDA) is included in many worldwide codes and specifications
(Beim, 2008), so it is now routine standard practice. In fact, the PDA has become the
most common measurement tool for assessing deep foundation performance.
For the first few decades, the routine dynamic test consisted of the engineer
arriving on site with the test equipment, attaching the sensors to the pile and entering
sensor calibrations and pile properties into the PDA. Upon hammer impact, the
signals from the sensors were sent via a cable to the PDA. The engineer evaluated
data on site blow by blow in real time by the Case Method. After field tests, critical
data from end of drive or restrike was analyzed by CAPWAP®
signal matching to
obtain ultimate capacity, resistance distribution, and damping constants.
NEW POSSIBILITIES
Continual improvement in communication electronics has allowed alternate modes
of operation that provide distinct advantages.
Data quality is of primary importance. Calibration of the sensors is obviously
critical since the derived result is directly affected by signal sensitivity. There is an
industry trend for the sensor to know and transmit its sensitivity to the parent data
collection system using memory chips now installed in the sensors. Automatic
detection of unusual signals further warns the engineer of suspect data quality.
Experience has shown that sometimes the cause of poor data is damage to or
fatigue of the cables transmitting the signal from the pile to the PDA. The PDA
can be equipped for “wireless” Bluetooth data transmission (Figure 1, 2), eliminating
the main signal transmission cable entirely. A small battery powered
transmitter transmits the data to the receiving PDA, located up to 100 meters from the
pile.
FIG. 1. Wireless sensors and
transmitter.
FIG.2. Wireless PDA in operation.
3
The sensors and transmitters can be protected by hard foam pads, allowing
instrumentation to be attached to the pile on the ground prior to lifting the pile into
the leads. For full length pile monitoring, this reduces testing time and improves
safety because climbing the leads to attach the sensors is eliminated.
Wireless technology can send data from the jobsite to any worldwide destination
using the internet. “Remote” testing was conceived and first enabled over 10 years
ago through serial data transmission on TAPI cell phone systems (Gravare 2000).
In remote testing, the PDA is on site with the pile crew and a neutral observer to
answer any questions from the PDA engineer. The sensors are attached to the pile by
the pile crew, who already often attach the sensors even when the PDA engineer is on
site. During remote testing, the PDA engineer may be anywhere in the world, but
typically is in his office location, usually hours from the jobsite. Connection was
made from the site PDA to the engineer’s office computer. Data was then sent
serially, although typically slow transmission rates resulted in a real time sample of
about every sixth blow in continuous operation, or a short delay in time if a limited
number of restrike blows were requested. Since every blow was captured by the
PDA, all data could later be retrieved when requested.
Recently, the PDA has adapted to transmit data through cell phones equipped to
access the internet. Through internet communications, the PDA is now able to
achieve a significantly higher speed of data transfer; typically every second or third
blow can be sent in real time, and perhaps every blow in the near future.
BENEFITS FROM CHANGE IN PRACTICE
Compared with having the PDA engineer on site, what real advantages are
achieved with this “new technology”? Will the test produce the same quality
measurements as with traditional on-site testing? Assuming all parties are willing to
step out of their “comfort zone”, how is the new technology best implemented?
Consider that if the engineer did not need travel time to return from the site to the
office, the engineer could instead immediately begin data analysis (e.g. CAPWAP)
and write the report sooner. Getting the results sooner can be vital to the project since
this information is often on the project’s critical path. The installation criterion can
be established sooner and production piles then installed with confidence.
In traditional on-site testing, the test is scheduled conveniently for both contractor
and tester. Often the PDA engineer is not available for last minute requests or
“emergencies” (e.g. pile obtains a different blow count or vastly different penetration
than expected). If the remote PDA is already on the site, a quick call to the PDA
engineer is all that is needed to test and resolve the current crisis. Testing costs are
known which allows more accurate budgeting.
Tests which involve installation testing followed by restrikes after several days
wait time (or multiple tests) to observe the ultimate capacity with time, or to observe
hammer consistency, can be easily scheduled at the contractor’s convenience with the
PDA on site. For example, the engineer may test on-site for the initial installation, but
leave the PDA on site for several days to allow for set-up and then perform a restrike
test in a remote mode. The end result is a better design with more complete testing,
thus reducing risk, and possible significant foundation savings.
4
Although the above justifications are often more compelling reasons to implement
this new technology, traditional on-site testing generates significant travel time
charges and travel time costs. Further, much of the engineer’s time on site is actually
spent waiting for something to happen. The direct engineering time of collecting data
is often a small percentage of time billed, particularly for restrike tests. At some sites,
extra training for safety required to enter the jobsite can be eliminated with remote
testing. By eliminating all travel time and all travel costs, and eliminating all on-site
non-testing time, the actual cost of the test is significantly reduced.
From the engineer’s view, travel to site can be greatly reduced, and in many cases
eliminated. Remote technology allows the PDA engineer to efficiently test piles from
multiple jobsites, even from multiple countries, during the same day. Since there is
an increasing concern for quality of testing (Seidel, 2000), access to the more
experienced testers can be improved.
These reasons all help to keep the project on schedule and under budget. So how
is remote technology best initially implemented? On larger projects, the tester might
come to the site at the beginning (and train the crew to attach the sensors to the pile, if
needed), but leave the equipment on site for later restrike tests. After developing
sufficient confidence, future tests may be performed remotely. An independent on-
site observer, usually already present to collect a driving record or assure the
installation criterion has been met, can be the test engineer’s eyes and ears. The test
engineer in the office sees the same data, and can easily assess data quality from his
office. If there is a problem with data quality, the test engineer simply instructs the
site personnel to address the attachment of the problem sensor, and repeat the test.
The engineer can transmit his findings instantaneously during the testing to the site,
and even direct when the pile driving may be terminated.
Swedish Experience
High strain dynamic tests on driven piles have been routinely carried out in
Sweden for approximately 30 years (Gravare 2004). Most pile tests are carried out
during redriving to evaluate the bearing capacity including time-dependent set-up
effects. The long distances in Sweden cause several hours of traveling for typically
less than one hour of testing, such as testing three piles in a bridge abutment.
Since the first remote test 10 years ago in Sweden, the transition to remote testing
has been fast and nowadays most PDA tests in Sweden are remote tests. Altogether
13 remote units are currently operated in Sweden (Fig. 3). To receive data from up to
10 sites per day, a team of four consulting engineers operates a network of six
computers connected to the remote PDA units via modem or internet connection. The
network allows quick movement between different sites in busy situations. Multiple
engineers can immediately review difficult to interpret data and reach a fast
judgment. The new remote unit with internet transmission allows monitoring during
driving.
Properly attaching the transducers to the pile is essential for good data quality.
Even though many Swedish piling crews are familiar with attaching sensors, it is still
important to study data quality of each transducer individually. The force transducers
particularly require correct attachment. The most common problem, incorrect spacing
5
between the attachment holes, stretches the strain transducer beyond the PDA
balancing range. The experienced site crew will notice field PDA then displays “Not
Available” and drill new holes before starting testing. The balancing status can be
viewed by the remote engineer, and adjustments made if required, prior to testing.
For concrete piles, if attachment bolts are too long they bottom out on the anchors
rather than bearing on the transducer. This is not always discovered on site as the
crew experiences they have tightened the bolts as much as possible. This problem is
easily detected in the office by the transmitted vibrating signal. Accelerometers not
properly oriented parallel to the pile axis result in poor force-velocity proportionality.
FIG.3. Remote PDA tests in Sweden
To prevent the same pile being tested over and over again (with different pile
numbers sent to the engineer), the engineer can inspect the strain transducer balancing
which should change when moved from pile to pile and, of course, look at the data
itself to see if it is identical to the trace of that just previously tested. During many
past years of remote testing this has not been a big problem.
As mentioned above, the remote testing saves travel time that can be used for
evaluating and reporting. In a very urgent situation, remote testing, CAPWAP
analysis and report writing were carried out simultaneously (by three engineers on
three piles) and the client received the results shortly after the test was finished.
UK Experience
Dynamic pile testing has been carried out in the UK since 1979. Initially testing
was carried out mainly on driven precast concrete piles with some testing of driven
steel tubular and H-piles. As experience grew, dynamic load testing was carried out
to cast in place piles and steel sheet piles. In the early years, reliable dynamic load
testing required highly trained engineers to travel to site to carry out the testing and
physically transport the test data to the office for CAPWAP analysis. This analysis
and subsequent report would often be carried out some days after the site testing.
6
In the late 1990’s the advent of the first remote PDA presented an opportunity for
a step change in the method of working, while still ensuring the highest quality of test
data, essential to valid data analysis by CAPWAP. This remote PDA was quickly
adopted in the UK as soon as it was available. The ability of the remote PDA to
transmit data from site, during testing, and for an office based expert to assess the
data and carry out immediate CAPWAP analysis has many advantages. Today the
client can now expect almost immediate test results and same day reporting.
Quality is a key issue in any test and dynamic load testing by the remote PDA
allows the expert control of all aspects of the test. The expert sends commands to the
remote equipment to control its operation as if he were on site. The expert sees the
data from each sensor to assess the data quality (and if anything is amiss, then can
instruct the field crew to address and correct the problem prior to completing the test).
This expert control of all testing is a key aspect of quality control.
The UK is a geographically small area. Remote pile testing equipment based with
centrally and regionally based testing technicians can service sites in the UK more
efficiently than moving the PDA from site to site by courier. The use of a dedicated
trained technician rather than client supplied operatives ensures consistency of test
data and rapid testing with no site delays. It is possible to test 10 piles per hour.
Today in the UK the use of the remote PDA allows clients to have UKAS
accredited dynamic load testing carried out by locally based testing technicians
supported real-time by office based expert engineers. This delivers a fast reliable
service demanded in modern UK construction.
Australian Experience - Contractor View
High strain dynamic testing has become a routine part of the quality assurance
process for foundations in Australia since 1983. Today, except for small projects, 5
to 10% of all driven piles are dynamically tested. Remote dynamic testing has been in
regular use in Australia since 2001.
The introduction of the remote system has provided substantial cost savings for
many projects located more than 1000 km from the nearest office of the testing
engineer, requiring many hours of travel to and from the site. The reduction in testing
costs have been substantial (by up to 75%) where intermittent testing has been
required, with one of the most significant savings being associated with the reduction
in “down time” by the site crews waiting for the engineer to arrive on site after a
special or additional test has been required. In some isolated project sites, the down
time waiting for a traditional on-site test has been almost 24 hours. Where remote
testing can be utilized, this down time can be eliminated. Not only are there time
savings, but the ‘hidden’ costs of the safety of the engineer traveling long distances to
isolated project sites cannot be under estimated. Additional cost savings can also be
associated with the elimination of on-site safety instructions for the testing engineer,
which in some circumstances for mining sites can be more than one day.
The early remote systems relied on the mobile phone network with relatively slow
data transfer. Monitoring of the pile driving during installation was less than ideal as
every 7th
or 8th
blow would only be received by the remote computer in real time.
Therefore, many driving tests required the testing engineer on site and only the
7
subsequent restrike tests were completed in remote mode (in restrike mode, every
blow is sent sequentially). However, the recent introduction of the high speed
internet broadband communications allows all blows to be received in real time,
creating no disadvantage for remote testing during initial driving.
Many piling Supervisors are very familiar with the processes required for
collecting dynamic test data. Sensor attachment, cable connections and data
communications set-up are routine. However, the successful completion of the
remote PDA test requires clear communication between the field staff and the testing
engineer in the office. Firstly, the testing engineer needs to be familiar with the
remote testing equipment to problem-solve any issues that may arise, particularly for
field personnel unfamiliar with the process. Secondly, the testing engineer must have
sufficient experience with piling to ask appropriate questions of the field staff to
gather all relevant information about the pile being tested.
With the remote testing engineer usually located in an office environment, other
more experienced engineers are usually on hand to provide assistance and advice
where required, providing quick assessments of piling test data on the critical path.
Australian Experience – Consultant View
Independent consulting using dynamic pile testing operated by Australians first
began in Australia in 1984. Projects were conducted with the PDA operator on-site
Dynamic Pile testing Victoria and all over Australia and in many South East Asia and
Oceania countries. Independent testing in Australia is mostly in ports and bridges and
other heavy civil infrastructure with most projects now funded by the booming mining
sector of the economy.
Remote testing is a method particularly adapted to Australia’s vast distances and
low population density. Independent consulting jobs tend to be in remote locations
far from home base. Remote PDA systems were readily accepted owing to low
mobilization cost, speed of response owing to low/no travel time, convenience of
having the remote equipment available full-time on site for unscheduled use, and low
cost to postpone tests while problems with the piling system are being resolved. The
most common solution on large remote projects is to station the remote PDA
equipment on site for the duration of piling, often now required under the project
specification. Having the PDA operator on site is now unusual and only necessary if
there is no phone system available.
Each PDA system is equipped with some minimum spare sensors. Multiple PDA
units can be serviced by one PDA engineer. Simultaneous testing is not common, but
can be accomplished with multiple receiving stations at the PDA engineer’s office.
Data can be received during off hours by unattended computers. The number of PDA
units operated by the sole PDA operator, currently 7 units by this consultant, is only
limited by the available time to analyze data and timely report the results.
Although many piling contractors and deep foundation engineers know dynamic
test methods, a step by step, button by button, guide is provided for field personnel
unfamiliar with remote PDA testing because there are still frequent new engineers in
the Contractor’s staff. When talking to people on site, it must be assumed they have
very low knowledge of the PDA system. Patience and consideration are essential.
8
Data is received on a notebook computer. Thus even a sole operator can receive
data at almost any time and location. The PDA engineer can be measuring data on
one site while at the same time receiving separate data on the notebook from another
location on the other side of the country. Frequently data is received in airport
facilities, while in transit stopped by the side of the road, and even in a moving taxi.
New fast internet-based PDA systems, in parallel with new advanced 3G mobile
phones for non-internet based systems, provide very fast and relatively stable transfer
of data, but they require some knowledge of windows-based pc’s by the user and
require stepping through more menus by the user.
SUMMARY
The new PDA technology can improve dynamic testing practices and result in
even better quality assurance and lower risk for deep foundations. Wireless data
transmission from the pile to the PDA improves data quality, and improves safety on
site. When remote PDA equipment is already on site, piles can be immediately tested
should problems arise. Data can be sent remotely using modern cell phones and the
internet from the pile crew to the PDA engineer, typically in his office, allowing for
better scheduling of testing, a more efficient use of engineer time, and considerably
reduced testing costs and reduced scheduling difficulties. Good communication with
the site and careful review of data are required to assure reliable results. Eliminating
the travel time, analysis of the data can then proceed immediately, resulting in faster
reporting of results, keeping installation of production piles on schedule. Different
operational experience is observed in remote testing, depending on the geography and
position of the tester.
REFERENCES
Beim, G., and Likins, G., (2008), « Worldwide dynamic foundation testing codes and
standards”, Proc. Of the 8th
Int’l Conf. on the Application of Stresswave Theory to
Piles, Lisbon, Portugal
Eiber, R.J., (1958), “A Preliminary Laboratory Investigation of the Prediction of
Static Pile Resistances in Sand”, Master’s Thesis, Dept. of Civil Engineering, Case
Institute of Technology, Cleveland Ohio.
Gravare, C-J.,Hermansson, I., Gravare, M. (2004), ”Swedish Practice for Verification
of Pile Bearing Capacity”, Proc. Of the 7th
Int’l Conf. on the Application of
Stresswave Theory to Piles, Kuala Lumpur, Malaysia
Seidel, J. (2000), “The need for quality assurance in the dynamic pile testing
industry”, Proc. Of the 6th
Int’l Conf. on the Application of Stresswave Theory to
Piles, Sao Paulo, Brazil

More Related Content

What's hot

IRJET- Hearing Loss Detection through Audiogram in Mobile Devices
IRJET-  	  Hearing Loss Detection through Audiogram in Mobile DevicesIRJET-  	  Hearing Loss Detection through Audiogram in Mobile Devices
IRJET- Hearing Loss Detection through Audiogram in Mobile DevicesIRJET Journal
 
Breakthrough in Quality Management
Breakthrough in Quality ManagementBreakthrough in Quality Management
Breakthrough in Quality ManagementOptimalPlus
 
IEEE Buenaventura cs Chapter March 9 2016 v4
IEEE Buenaventura cs Chapter March 9 2016  v4IEEE Buenaventura cs Chapter March 9 2016  v4
IEEE Buenaventura cs Chapter March 9 2016 v4Sailaja Tennati
 
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKS
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKSBEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKS
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKSwle-ss
 
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...OptimalPlus
 
Bosch ConnectedWorld 2017: Striving for Zero DPPM
Bosch ConnectedWorld 2017: Striving for Zero DPPMBosch ConnectedWorld 2017: Striving for Zero DPPM
Bosch ConnectedWorld 2017: Striving for Zero DPPMDavid Park
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Controlling interests editors
Controlling interests editorsControlling interests editors
Controlling interests editorseldhoev
 
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...Kenexis
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Dräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureDräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureThorne & Derrick UK
 
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetDrager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Catalogo general general electric geit 10012 en-rev6_final
Catalogo general general electric geit 10012 en-rev6_finalCatalogo general general electric geit 10012 en-rev6_final
Catalogo general general electric geit 10012 en-rev6_finalPablo Bavarisco
 
Innovations for Asset Integrity Management
Innovations for Asset Integrity ManagementInnovations for Asset Integrity Management
Innovations for Asset Integrity ManagementSGS
 
Real-World Applications of OMG Technology in Medicine
Real-World Applications of OMG Technology in MedicineReal-World Applications of OMG Technology in Medicine
Real-World Applications of OMG Technology in MedicineReal-Time Innovations (RTI)
 
Drager Gas Measurement & Gas Sampling - A Laboratory Behind Glass
Drager Gas Measurement & Gas Sampling - A Laboratory Behind GlassDrager Gas Measurement & Gas Sampling - A Laboratory Behind Glass
Drager Gas Measurement & Gas Sampling - A Laboratory Behind GlassThorne & Derrick UK
 
DFR Conference, March 2019
DFR  Conference, March 2019DFR  Conference, March 2019
DFR Conference, March 2019OptimalPlus
 
NDT for boilers by LABORELEC
NDT for boilers by LABORELECNDT for boilers by LABORELEC
NDT for boilers by LABORELECOsama Lari
 

What's hot (20)

IRJET- Hearing Loss Detection through Audiogram in Mobile Devices
IRJET-  	  Hearing Loss Detection through Audiogram in Mobile DevicesIRJET-  	  Hearing Loss Detection through Audiogram in Mobile Devices
IRJET- Hearing Loss Detection through Audiogram in Mobile Devices
 
Breakthrough in Quality Management
Breakthrough in Quality ManagementBreakthrough in Quality Management
Breakthrough in Quality Management
 
IEEE Buenaventura cs Chapter March 9 2016 v4
IEEE Buenaventura cs Chapter March 9 2016  v4IEEE Buenaventura cs Chapter March 9 2016  v4
IEEE Buenaventura cs Chapter March 9 2016 v4
 
AMD at ITC 2014
AMD at  ITC 2014AMD at  ITC 2014
AMD at ITC 2014
 
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKS
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKSBEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKS
BEST VALUE FOR MONEY THROUGH NUMERICAL OPTIMIZATION OF WATER AND SENSOR NETWORKS
 
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...
Leveraging Cross-Operational Test Data for Manufacturing Yield and DPPM/RMA I...
 
Bosch ConnectedWorld 2017: Striving for Zero DPPM
Bosch ConnectedWorld 2017: Striving for Zero DPPMBosch ConnectedWorld 2017: Striving for Zero DPPM
Bosch ConnectedWorld 2017: Striving for Zero DPPM
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
 
Drager Fixed Gas Detectors Product Brochure
Drager Fixed Gas Detectors Product BrochureDrager Fixed Gas Detectors Product Brochure
Drager Fixed Gas Detectors Product Brochure
 
Controlling interests editors
Controlling interests editorsControlling interests editors
Controlling interests editors
 
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...
Optimizing Fire3 and Gas System Design Using the ISA Technical Report ISA TR8...
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
 
Dräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - BrochureDräger Fixed Gas Detectors - Brochure
Dräger Fixed Gas Detectors - Brochure
 
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec SheetDrager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
 
Catalogo general general electric geit 10012 en-rev6_final
Catalogo general general electric geit 10012 en-rev6_finalCatalogo general general electric geit 10012 en-rev6_final
Catalogo general general electric geit 10012 en-rev6_final
 
Innovations for Asset Integrity Management
Innovations for Asset Integrity ManagementInnovations for Asset Integrity Management
Innovations for Asset Integrity Management
 
Real-World Applications of OMG Technology in Medicine
Real-World Applications of OMG Technology in MedicineReal-World Applications of OMG Technology in Medicine
Real-World Applications of OMG Technology in Medicine
 
Drager Gas Measurement & Gas Sampling - A Laboratory Behind Glass
Drager Gas Measurement & Gas Sampling - A Laboratory Behind GlassDrager Gas Measurement & Gas Sampling - A Laboratory Behind Glass
Drager Gas Measurement & Gas Sampling - A Laboratory Behind Glass
 
DFR Conference, March 2019
DFR  Conference, March 2019DFR  Conference, March 2019
DFR Conference, March 2019
 
NDT for boilers by LABORELEC
NDT for boilers by LABORELECNDT for boilers by LABORELEC
NDT for boilers by LABORELEC
 

Viewers also liked

Оживљавање
ОживљавањеОживљавање
Оживљавањеvernomesto
 
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...Ágnes Koreny
 
Mercy cadena slideshare
Mercy cadena slideshareMercy cadena slideshare
Mercy cadena slidesharemercycadena
 
Stategi for bedrift
Stategi for bedriftStategi for bedrift
Stategi for bedriftmarenkambu
 
Mercy cadena slideshare
Mercy cadena slideshareMercy cadena slideshare
Mercy cadena slidesharemercycadena
 
High strain dynamic pile testing - Independent Geoscience Pty Ltd
High strain dynamic pile testing - Independent Geoscience Pty LtdHigh strain dynamic pile testing - Independent Geoscience Pty Ltd
High strain dynamic pile testing - Independent Geoscience Pty LtdIndependent Geoscience
 
Potential Energy
Potential Energy Potential Energy
Potential Energy Binu George
 

Viewers also liked (8)

Оживљавање
ОживљавањеОживљавање
Оживљавање
 
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...
Hozzáférés és újrahasznosítás. A TEL és az Europeana a tudományos kutatás szo...
 
Mercy cadena slideshare
Mercy cadena slideshareMercy cadena slideshare
Mercy cadena slideshare
 
Stategi for bedrift
Stategi for bedriftStategi for bedrift
Stategi for bedrift
 
Open 2016 Torino
Open 2016 TorinoOpen 2016 Torino
Open 2016 Torino
 
Mercy cadena slideshare
Mercy cadena slideshareMercy cadena slideshare
Mercy cadena slideshare
 
High strain dynamic pile testing - Independent Geoscience Pty Ltd
High strain dynamic pile testing - Independent Geoscience Pty LtdHigh strain dynamic pile testing - Independent Geoscience Pty Ltd
High strain dynamic pile testing - Independent Geoscience Pty Ltd
 
Potential Energy
Potential Energy Potential Energy
Potential Energy
 

Similar to Advances dynamic pile testing technology - Independent Geoscience Pty Ltd

Takaya Flying Probe Tester.pdf
Takaya Flying Probe Tester.pdfTakaya Flying Probe Tester.pdf
Takaya Flying Probe Tester.pdfEquip-Test Kft
 
Automated Site Verification | Solution Brief | Infovista
Automated Site Verification | Solution Brief | InfovistaAutomated Site Verification | Solution Brief | Infovista
Automated Site Verification | Solution Brief | InfovistaInfovista
 
Anup resume new
Anup resume newAnup resume new
Anup resume newAnup Singh
 
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...yieldWerx Semiconductor
 
Whitepaper fluke
Whitepaper flukeWhitepaper fluke
Whitepaper flukeClair Kirby
 
resume_updated
resume_updatedresume_updated
resume_updatedsharp338
 
DMCOM_capability statement_v1
DMCOM_capability statement_v1DMCOM_capability statement_v1
DMCOM_capability statement_v1Rudy Moniaga
 
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...Thorne & Derrick International
 
CSE5 ITP High Density Wireless Design REPORT
CSE5 ITP High Density Wireless Design REPORTCSE5 ITP High Density Wireless Design REPORT
CSE5 ITP High Density Wireless Design REPORTsaieshwar chellapuram
 
Enabling Cloud Storage Auditing with Key Exposure Resistance
Enabling Cloud Storage Auditing with Key Exposure ResistanceEnabling Cloud Storage Auditing with Key Exposure Resistance
Enabling Cloud Storage Auditing with Key Exposure ResistanceIRJET Journal
 
Sense And Trace
Sense And TraceSense And Trace
Sense And TraceAshray Jha
 
Low Cost Rail Crack Inspection System
Low Cost Rail Crack Inspection SystemLow Cost Rail Crack Inspection System
Low Cost Rail Crack Inspection SystemEditor IJMTER
 
LORA BASED DATA ACQUISITION SYSTEM
LORA BASED DATA ACQUISITION SYSTEMLORA BASED DATA ACQUISITION SYSTEM
LORA BASED DATA ACQUISITION SYSTEMIRJET Journal
 

Similar to Advances dynamic pile testing technology - Independent Geoscience Pty Ltd (20)

CV_Gunjan Gunjan
CV_Gunjan GunjanCV_Gunjan Gunjan
CV_Gunjan Gunjan
 
KW resume 2015
KW resume 2015KW resume 2015
KW resume 2015
 
Takaya Flying Probe Tester.pdf
Takaya Flying Probe Tester.pdfTakaya Flying Probe Tester.pdf
Takaya Flying Probe Tester.pdf
 
CV-Nidhin
CV-NidhinCV-Nidhin
CV-Nidhin
 
Automated Site Verification | Solution Brief | Infovista
Automated Site Verification | Solution Brief | InfovistaAutomated Site Verification | Solution Brief | Infovista
Automated Site Verification | Solution Brief | Infovista
 
Anup resume new
Anup resume newAnup resume new
Anup resume new
 
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...
The Indispensable Role of Outlier Detection for Ensuring Semiconductor Qualit...
 
Whitepaper fluke
Whitepaper flukeWhitepaper fluke
Whitepaper fluke
 
resume_updated
resume_updatedresume_updated
resume_updated
 
CV-Nidhin
CV-NidhinCV-Nidhin
CV-Nidhin
 
DMCOM_capability statement_v1
DMCOM_capability statement_v1DMCOM_capability statement_v1
DMCOM_capability statement_v1
 
CV-Nidhin
CV-NidhinCV-Nidhin
CV-Nidhin
 
Timing Challenges in the Smart Grid
Timing Challenges in the Smart GridTiming Challenges in the Smart Grid
Timing Challenges in the Smart Grid
 
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...
Seaward - Electrical Testing & Voltage Detection, High Voltage Safety, HV Ind...
 
CSE5 ITP High Density Wireless Design REPORT
CSE5 ITP High Density Wireless Design REPORTCSE5 ITP High Density Wireless Design REPORT
CSE5 ITP High Density Wireless Design REPORT
 
Enabling Cloud Storage Auditing with Key Exposure Resistance
Enabling Cloud Storage Auditing with Key Exposure ResistanceEnabling Cloud Storage Auditing with Key Exposure Resistance
Enabling Cloud Storage Auditing with Key Exposure Resistance
 
Profile tulasi v1.1
Profile tulasi v1.1Profile tulasi v1.1
Profile tulasi v1.1
 
Sense And Trace
Sense And TraceSense And Trace
Sense And Trace
 
Low Cost Rail Crack Inspection System
Low Cost Rail Crack Inspection SystemLow Cost Rail Crack Inspection System
Low Cost Rail Crack Inspection System
 
LORA BASED DATA ACQUISITION SYSTEM
LORA BASED DATA ACQUISITION SYSTEMLORA BASED DATA ACQUISITION SYSTEM
LORA BASED DATA ACQUISITION SYSTEM
 

Recently uploaded

Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.eptoze12
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...asadnawaz62
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2RajaP95
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxk795866
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 

Recently uploaded (20)

Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
POWER SYSTEMS-1 Complete notes examples
POWER SYSTEMS-1 Complete notes  examplesPOWER SYSTEMS-1 Complete notes  examples
POWER SYSTEMS-1 Complete notes examples
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 
young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Serviceyoung call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
Introduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptxIntroduction-To-Agricultural-Surveillance-Rover.pptx
Introduction-To-Agricultural-Surveillance-Rover.pptx
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 

Advances dynamic pile testing technology - Independent Geoscience Pty Ltd

  • 1. 1 ADVANCES IN DYNAMIC FOUNDATION TESTING TECHNOLOGY Garland Likins, P.E., MASCE 1 Ingemar Hermansson2 , Mike Kightley3 , Jon Cannon4 , and David Klingberg5 1 President, Pile Dynamics, Inc., 4535 Renaissance Parkway, Cleveland OH 44128, USA; ph: 216-831- 6131; fax: 216-831-0916; email: garland@pile.com 2 Partner, Palanalys, August Barks Gata 13C, 421 32 Vastra, Frolunda, Sweden; ph: 46 31-45 43 07; fax: 46 31-45 99 80; email: ingemar@palanalys.se 3 Managing Director, Testing and Analysis Ltd, Birchwood Way, Somercotes, Alfreton Derbyshire DE55 4QQ UK; ph: 44-1773-540880; fax: 44-1773-540760; email: mike.kightley@testal.co.uk 4 Managing Director, Independent GeoSciences, 2 Letchworth Avenue, Brighton East, Victoria 3187, Australia; ph: 61 3 9553-8288; fax: 61 3 9553-8288; email: indgeo@optushome.com.au 5 Piletest Manager, Wagstaff Piling, 1 Ashgrove Crescent, Brisbane, 4060 Queensland, Australia, ph: 61-7 3366 2555; fax: 61-7 3366 5608; email: d.klingberg@wagsttaffpiling.com.au ABSTRACT: While dynamic pile testing is not new, and is included in many worldwide codes and specifications, dramatic changes from traditional testing methods and common practice have occurred in recent years. Traditionally, the sensors send their signals through a cable to the data acquisition equipment. Experience has shown that some poor data is caused by damage to or fatigue of these cables. New equipment now transmits sensor data from the pile wirelessly by Bluetooth to receiving antennas on the data collection equipment. “Wireless” technology eliminates the cables and improves data quality. Sensors which remember their calibration sensitivity and transmit that information eliminate another common problem in data quality, namely having the wrong calibration assigned. Methods of protecting the sensors during installation allow attaching sensors prior to lifting the pile into the hammer leads, and hence speeding up the testing process, and promote safety. The most radical change in the data acquisition process is “remote” dynamic testing, which has revolutionized dynamic testing in some parts of the world. In remote testing, the data acquisition equipment is operated on site by an inspector or the pile crew, and sends the data over the internet to the test engineer in his office. The wireless and remote procedures are described and example experiences indicate the great benefits, and areas of caution, of the new technology. INTRODUCTION Dynamic pile testing is not new. The original research began over 50 years ago at Case Western Reserve University (Eiber, 1958). Dynamic testing with the Pile
  • 2. 2 Driving Analyzer® (PDA) is included in many worldwide codes and specifications (Beim, 2008), so it is now routine standard practice. In fact, the PDA has become the most common measurement tool for assessing deep foundation performance. For the first few decades, the routine dynamic test consisted of the engineer arriving on site with the test equipment, attaching the sensors to the pile and entering sensor calibrations and pile properties into the PDA. Upon hammer impact, the signals from the sensors were sent via a cable to the PDA. The engineer evaluated data on site blow by blow in real time by the Case Method. After field tests, critical data from end of drive or restrike was analyzed by CAPWAP® signal matching to obtain ultimate capacity, resistance distribution, and damping constants. NEW POSSIBILITIES Continual improvement in communication electronics has allowed alternate modes of operation that provide distinct advantages. Data quality is of primary importance. Calibration of the sensors is obviously critical since the derived result is directly affected by signal sensitivity. There is an industry trend for the sensor to know and transmit its sensitivity to the parent data collection system using memory chips now installed in the sensors. Automatic detection of unusual signals further warns the engineer of suspect data quality. Experience has shown that sometimes the cause of poor data is damage to or fatigue of the cables transmitting the signal from the pile to the PDA. The PDA can be equipped for “wireless” Bluetooth data transmission (Figure 1, 2), eliminating the main signal transmission cable entirely. A small battery powered transmitter transmits the data to the receiving PDA, located up to 100 meters from the pile. FIG. 1. Wireless sensors and transmitter. FIG.2. Wireless PDA in operation.
  • 3. 3 The sensors and transmitters can be protected by hard foam pads, allowing instrumentation to be attached to the pile on the ground prior to lifting the pile into the leads. For full length pile monitoring, this reduces testing time and improves safety because climbing the leads to attach the sensors is eliminated. Wireless technology can send data from the jobsite to any worldwide destination using the internet. “Remote” testing was conceived and first enabled over 10 years ago through serial data transmission on TAPI cell phone systems (Gravare 2000). In remote testing, the PDA is on site with the pile crew and a neutral observer to answer any questions from the PDA engineer. The sensors are attached to the pile by the pile crew, who already often attach the sensors even when the PDA engineer is on site. During remote testing, the PDA engineer may be anywhere in the world, but typically is in his office location, usually hours from the jobsite. Connection was made from the site PDA to the engineer’s office computer. Data was then sent serially, although typically slow transmission rates resulted in a real time sample of about every sixth blow in continuous operation, or a short delay in time if a limited number of restrike blows were requested. Since every blow was captured by the PDA, all data could later be retrieved when requested. Recently, the PDA has adapted to transmit data through cell phones equipped to access the internet. Through internet communications, the PDA is now able to achieve a significantly higher speed of data transfer; typically every second or third blow can be sent in real time, and perhaps every blow in the near future. BENEFITS FROM CHANGE IN PRACTICE Compared with having the PDA engineer on site, what real advantages are achieved with this “new technology”? Will the test produce the same quality measurements as with traditional on-site testing? Assuming all parties are willing to step out of their “comfort zone”, how is the new technology best implemented? Consider that if the engineer did not need travel time to return from the site to the office, the engineer could instead immediately begin data analysis (e.g. CAPWAP) and write the report sooner. Getting the results sooner can be vital to the project since this information is often on the project’s critical path. The installation criterion can be established sooner and production piles then installed with confidence. In traditional on-site testing, the test is scheduled conveniently for both contractor and tester. Often the PDA engineer is not available for last minute requests or “emergencies” (e.g. pile obtains a different blow count or vastly different penetration than expected). If the remote PDA is already on the site, a quick call to the PDA engineer is all that is needed to test and resolve the current crisis. Testing costs are known which allows more accurate budgeting. Tests which involve installation testing followed by restrikes after several days wait time (or multiple tests) to observe the ultimate capacity with time, or to observe hammer consistency, can be easily scheduled at the contractor’s convenience with the PDA on site. For example, the engineer may test on-site for the initial installation, but leave the PDA on site for several days to allow for set-up and then perform a restrike test in a remote mode. The end result is a better design with more complete testing, thus reducing risk, and possible significant foundation savings.
  • 4. 4 Although the above justifications are often more compelling reasons to implement this new technology, traditional on-site testing generates significant travel time charges and travel time costs. Further, much of the engineer’s time on site is actually spent waiting for something to happen. The direct engineering time of collecting data is often a small percentage of time billed, particularly for restrike tests. At some sites, extra training for safety required to enter the jobsite can be eliminated with remote testing. By eliminating all travel time and all travel costs, and eliminating all on-site non-testing time, the actual cost of the test is significantly reduced. From the engineer’s view, travel to site can be greatly reduced, and in many cases eliminated. Remote technology allows the PDA engineer to efficiently test piles from multiple jobsites, even from multiple countries, during the same day. Since there is an increasing concern for quality of testing (Seidel, 2000), access to the more experienced testers can be improved. These reasons all help to keep the project on schedule and under budget. So how is remote technology best initially implemented? On larger projects, the tester might come to the site at the beginning (and train the crew to attach the sensors to the pile, if needed), but leave the equipment on site for later restrike tests. After developing sufficient confidence, future tests may be performed remotely. An independent on- site observer, usually already present to collect a driving record or assure the installation criterion has been met, can be the test engineer’s eyes and ears. The test engineer in the office sees the same data, and can easily assess data quality from his office. If there is a problem with data quality, the test engineer simply instructs the site personnel to address the attachment of the problem sensor, and repeat the test. The engineer can transmit his findings instantaneously during the testing to the site, and even direct when the pile driving may be terminated. Swedish Experience High strain dynamic tests on driven piles have been routinely carried out in Sweden for approximately 30 years (Gravare 2004). Most pile tests are carried out during redriving to evaluate the bearing capacity including time-dependent set-up effects. The long distances in Sweden cause several hours of traveling for typically less than one hour of testing, such as testing three piles in a bridge abutment. Since the first remote test 10 years ago in Sweden, the transition to remote testing has been fast and nowadays most PDA tests in Sweden are remote tests. Altogether 13 remote units are currently operated in Sweden (Fig. 3). To receive data from up to 10 sites per day, a team of four consulting engineers operates a network of six computers connected to the remote PDA units via modem or internet connection. The network allows quick movement between different sites in busy situations. Multiple engineers can immediately review difficult to interpret data and reach a fast judgment. The new remote unit with internet transmission allows monitoring during driving. Properly attaching the transducers to the pile is essential for good data quality. Even though many Swedish piling crews are familiar with attaching sensors, it is still important to study data quality of each transducer individually. The force transducers particularly require correct attachment. The most common problem, incorrect spacing
  • 5. 5 between the attachment holes, stretches the strain transducer beyond the PDA balancing range. The experienced site crew will notice field PDA then displays “Not Available” and drill new holes before starting testing. The balancing status can be viewed by the remote engineer, and adjustments made if required, prior to testing. For concrete piles, if attachment bolts are too long they bottom out on the anchors rather than bearing on the transducer. This is not always discovered on site as the crew experiences they have tightened the bolts as much as possible. This problem is easily detected in the office by the transmitted vibrating signal. Accelerometers not properly oriented parallel to the pile axis result in poor force-velocity proportionality. FIG.3. Remote PDA tests in Sweden To prevent the same pile being tested over and over again (with different pile numbers sent to the engineer), the engineer can inspect the strain transducer balancing which should change when moved from pile to pile and, of course, look at the data itself to see if it is identical to the trace of that just previously tested. During many past years of remote testing this has not been a big problem. As mentioned above, the remote testing saves travel time that can be used for evaluating and reporting. In a very urgent situation, remote testing, CAPWAP analysis and report writing were carried out simultaneously (by three engineers on three piles) and the client received the results shortly after the test was finished. UK Experience Dynamic pile testing has been carried out in the UK since 1979. Initially testing was carried out mainly on driven precast concrete piles with some testing of driven steel tubular and H-piles. As experience grew, dynamic load testing was carried out to cast in place piles and steel sheet piles. In the early years, reliable dynamic load testing required highly trained engineers to travel to site to carry out the testing and physically transport the test data to the office for CAPWAP analysis. This analysis and subsequent report would often be carried out some days after the site testing.
  • 6. 6 In the late 1990’s the advent of the first remote PDA presented an opportunity for a step change in the method of working, while still ensuring the highest quality of test data, essential to valid data analysis by CAPWAP. This remote PDA was quickly adopted in the UK as soon as it was available. The ability of the remote PDA to transmit data from site, during testing, and for an office based expert to assess the data and carry out immediate CAPWAP analysis has many advantages. Today the client can now expect almost immediate test results and same day reporting. Quality is a key issue in any test and dynamic load testing by the remote PDA allows the expert control of all aspects of the test. The expert sends commands to the remote equipment to control its operation as if he were on site. The expert sees the data from each sensor to assess the data quality (and if anything is amiss, then can instruct the field crew to address and correct the problem prior to completing the test). This expert control of all testing is a key aspect of quality control. The UK is a geographically small area. Remote pile testing equipment based with centrally and regionally based testing technicians can service sites in the UK more efficiently than moving the PDA from site to site by courier. The use of a dedicated trained technician rather than client supplied operatives ensures consistency of test data and rapid testing with no site delays. It is possible to test 10 piles per hour. Today in the UK the use of the remote PDA allows clients to have UKAS accredited dynamic load testing carried out by locally based testing technicians supported real-time by office based expert engineers. This delivers a fast reliable service demanded in modern UK construction. Australian Experience - Contractor View High strain dynamic testing has become a routine part of the quality assurance process for foundations in Australia since 1983. Today, except for small projects, 5 to 10% of all driven piles are dynamically tested. Remote dynamic testing has been in regular use in Australia since 2001. The introduction of the remote system has provided substantial cost savings for many projects located more than 1000 km from the nearest office of the testing engineer, requiring many hours of travel to and from the site. The reduction in testing costs have been substantial (by up to 75%) where intermittent testing has been required, with one of the most significant savings being associated with the reduction in “down time” by the site crews waiting for the engineer to arrive on site after a special or additional test has been required. In some isolated project sites, the down time waiting for a traditional on-site test has been almost 24 hours. Where remote testing can be utilized, this down time can be eliminated. Not only are there time savings, but the ‘hidden’ costs of the safety of the engineer traveling long distances to isolated project sites cannot be under estimated. Additional cost savings can also be associated with the elimination of on-site safety instructions for the testing engineer, which in some circumstances for mining sites can be more than one day. The early remote systems relied on the mobile phone network with relatively slow data transfer. Monitoring of the pile driving during installation was less than ideal as every 7th or 8th blow would only be received by the remote computer in real time. Therefore, many driving tests required the testing engineer on site and only the
  • 7. 7 subsequent restrike tests were completed in remote mode (in restrike mode, every blow is sent sequentially). However, the recent introduction of the high speed internet broadband communications allows all blows to be received in real time, creating no disadvantage for remote testing during initial driving. Many piling Supervisors are very familiar with the processes required for collecting dynamic test data. Sensor attachment, cable connections and data communications set-up are routine. However, the successful completion of the remote PDA test requires clear communication between the field staff and the testing engineer in the office. Firstly, the testing engineer needs to be familiar with the remote testing equipment to problem-solve any issues that may arise, particularly for field personnel unfamiliar with the process. Secondly, the testing engineer must have sufficient experience with piling to ask appropriate questions of the field staff to gather all relevant information about the pile being tested. With the remote testing engineer usually located in an office environment, other more experienced engineers are usually on hand to provide assistance and advice where required, providing quick assessments of piling test data on the critical path. Australian Experience – Consultant View Independent consulting using dynamic pile testing operated by Australians first began in Australia in 1984. Projects were conducted with the PDA operator on-site Dynamic Pile testing Victoria and all over Australia and in many South East Asia and Oceania countries. Independent testing in Australia is mostly in ports and bridges and other heavy civil infrastructure with most projects now funded by the booming mining sector of the economy. Remote testing is a method particularly adapted to Australia’s vast distances and low population density. Independent consulting jobs tend to be in remote locations far from home base. Remote PDA systems were readily accepted owing to low mobilization cost, speed of response owing to low/no travel time, convenience of having the remote equipment available full-time on site for unscheduled use, and low cost to postpone tests while problems with the piling system are being resolved. The most common solution on large remote projects is to station the remote PDA equipment on site for the duration of piling, often now required under the project specification. Having the PDA operator on site is now unusual and only necessary if there is no phone system available. Each PDA system is equipped with some minimum spare sensors. Multiple PDA units can be serviced by one PDA engineer. Simultaneous testing is not common, but can be accomplished with multiple receiving stations at the PDA engineer’s office. Data can be received during off hours by unattended computers. The number of PDA units operated by the sole PDA operator, currently 7 units by this consultant, is only limited by the available time to analyze data and timely report the results. Although many piling contractors and deep foundation engineers know dynamic test methods, a step by step, button by button, guide is provided for field personnel unfamiliar with remote PDA testing because there are still frequent new engineers in the Contractor’s staff. When talking to people on site, it must be assumed they have very low knowledge of the PDA system. Patience and consideration are essential.
  • 8. 8 Data is received on a notebook computer. Thus even a sole operator can receive data at almost any time and location. The PDA engineer can be measuring data on one site while at the same time receiving separate data on the notebook from another location on the other side of the country. Frequently data is received in airport facilities, while in transit stopped by the side of the road, and even in a moving taxi. New fast internet-based PDA systems, in parallel with new advanced 3G mobile phones for non-internet based systems, provide very fast and relatively stable transfer of data, but they require some knowledge of windows-based pc’s by the user and require stepping through more menus by the user. SUMMARY The new PDA technology can improve dynamic testing practices and result in even better quality assurance and lower risk for deep foundations. Wireless data transmission from the pile to the PDA improves data quality, and improves safety on site. When remote PDA equipment is already on site, piles can be immediately tested should problems arise. Data can be sent remotely using modern cell phones and the internet from the pile crew to the PDA engineer, typically in his office, allowing for better scheduling of testing, a more efficient use of engineer time, and considerably reduced testing costs and reduced scheduling difficulties. Good communication with the site and careful review of data are required to assure reliable results. Eliminating the travel time, analysis of the data can then proceed immediately, resulting in faster reporting of results, keeping installation of production piles on schedule. Different operational experience is observed in remote testing, depending on the geography and position of the tester. REFERENCES Beim, G., and Likins, G., (2008), « Worldwide dynamic foundation testing codes and standards”, Proc. Of the 8th Int’l Conf. on the Application of Stresswave Theory to Piles, Lisbon, Portugal Eiber, R.J., (1958), “A Preliminary Laboratory Investigation of the Prediction of Static Pile Resistances in Sand”, Master’s Thesis, Dept. of Civil Engineering, Case Institute of Technology, Cleveland Ohio. Gravare, C-J.,Hermansson, I., Gravare, M. (2004), ”Swedish Practice for Verification of Pile Bearing Capacity”, Proc. Of the 7th Int’l Conf. on the Application of Stresswave Theory to Piles, Kuala Lumpur, Malaysia Seidel, J. (2000), “The need for quality assurance in the dynamic pile testing industry”, Proc. Of the 6th Int’l Conf. on the Application of Stresswave Theory to Piles, Sao Paulo, Brazil