K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

RESEARCH ARTICLE

www.ijera.com

OPEN ACCESS

UPQC for Power Quality Improvement of Induction Motor Drive
with Reduced DC Link Voltage
K. Sravani, T. Subramanya Sastry
M-tech Student Scholar Department of Electrical & Electronics Engineering, JBIET Engineering College,
Moinabad;RR(Dt); A.P, India.
Associate Professor Department of Electrical & Electronics Engineering, JBIET Engineering College,
Moinabad;RR(Dt); A.P, India.
Abstract
The main aim of this project is ,this topology enables UPQC to have a reduced dc-link voltage without
compromising its compensation capability. Three-phase, four-wire unified Power Quality (UPQC) to improve
power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a
common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage
Source Inverter (VSI), The performance of the applied control algorithm is evaluated in terms of power-factor
correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in
a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. This
circuit consists of capacitor in series with the interfacing inductor of the shunt active filter. The series capacitor
enables reduction in dc-link voltage requirement of the shunt active filter and simultaneously compensating the
reactive power required by the load, so as to maintain unity power factor, without compromising its
performance. This allows us to match the dc-link voltage requirements of the series and shunt active filters with
a common dc-link capacitor. AC induction motor has a fixed in the output side to run the ac machine with
required speed. The proposed topology enables UPQC to compensate voltage sags, voltage swells and current
harmonics with a reduced DC-link voltage without compromising its compensation capability by implementing
the circuit in MATLAB/SIMULINK software.
Index Terms: Power quality, UPQC, Load balancing, voltage sags, voltage swells, AC Induction motor, APF

I.

INTRODUCTION

This proposed topology also helps to match
the dc-link voltage requirement of the shunt and series
active filters of the UPQC. The topology uses a
capacitor in series with the interfacing inductor of the
shunt active filter, and the system neutral is connected
to the negative terminal of the dc-link voltage to avoid
the requirement of the fourth leg in the voltage source
inverter (VSI) of the shunt active filter. The average
switching frequency of the switches in the VSI also
reduces; consequently the switching losses in the
inverters reduce. The main aim of this project this
topology enables UPQC to have a reduced dc-link
voltage without compromising its compensation
capability. The three phase three wires UPQC system
is used for compensation of power quality issues. In
this method the UPQC which requires more rating of
series and shunt active filters. Additionally to maintain
the Low harmonics level by adding passive filters.
The different topologies reported in literature
of three-phase four-wire UPQC use active
compensation for the mitigation of source neutral
current along with other PQ problems. For the
mitigation of source neutral current, the uses of
passive elements are advantageous over the active
compensation due to ruggedness and less complexity.
There are many techniques proposed for the
www.ijera.com

compensation of neutral current using star-delta
transformer in a three-phase four-wire distribution
system and some of these have been patented. The
application of star-delta transformer along with an
APF is also used for harmonic current reduction in the
neutral conductor. A filter employing three singlephase transformers with a capacitor has been used for
removing harmonic current from the neutral conductor
and has been patented. Another scheme by providing a
six-phase system, with the help of two transformers
connected in anti-phase has been reported for
canceling third harmonic current in neutral conductor.
The star-delta transformer along with a diode rectifier
and a half-bridge PWM inverter is also reported for
the compensation of neutral current. For the mitigation
of source neutral current along with other current
based distortions, the integration of readily available
three-leg VSI with star-delta transformer has been
reported in literature for 3P-4W DSTATCOM [6].
Unfortunately, for the mitigation of neutral current the
performance of the star-delta transformers is affected
to an extent under distorted or unbalanced source
voltages, which is very common in practice. The
UPQC is one of the key CPDs, which takes care of
both voltage and current based distortions
simultaneously. Hence, for neutral current mitigation
the integration of star-delta transformer with UPQC is
1374 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380
more justified. In this paper, a simple star-delta
configuration is utilized for the mitigation of source
neutral current, while other options such as zig-zag

www.ijera.com

transformer or T-connected transformer
specially designed transformers.

require

Fig.1. Equivalent circuit of neutral-clamped VSI topology-based UPQC
The conventional and proposed topology of
the UPQC are discussed in detail. Fig. 1 shows the
power circuit of the neutral-clamped VSI topologybased UPQC which is considered as the conventional
topology in this study. Even though this topology
requires two dc storage devices, each leg of the VSI
can be controlled independently, and tracking is
smooth with less number of switches when compared
to other VSI topologies. In this figure, vsa, vsb, and
vsc are source voltages of phases a, b, and c,
respectively. Similarly, vta, vtb, and vtc are terminal
voltages. The voltages vdvra, vdvrb, and vdvrc are
injected by the series active filter. The threephase
source currents are represented by isa, isb, and isc,
load currents are represented by ila, ilb, and ilc. The
shunt active filter currents are denoted by ifa, ifb, ifc,
and iln represents the current in the neutral leg. Ls
and Rs represent the feeder inductance and resistance,
respectively. The interfacing inductance and
resistance of the shunt active filter are represented by
Lf and Rf , respectively, and the interfacing
inductance and filter capacitor of the series active
filter are represented by Lse and Cse, respectively.
The load constituted of both linear and nonlinear
loads as shown in this figure. The dc-link capacitors
and voltages across them are represented by Cdc1 =
Cdc2 = Cdc and Vdc1 = Vdc2 = Vdc, respectively,
and the total dc-link voltage is represented by
Vdbus(Vdc1 + Vdc2 = 2Vdc).

II.

The system under consideration for threephase, four wire distribution system is shown in Fig.
2.The UPQC is connected before the load to make
the source and the load voltage free from any
distortions. At the same time, the reactive current
drawn from the source should be such that the
currents at source side would be in phase with utility
voltages. Provision is made to realize voltage
harmonics in the source voltage by switching on/off
the three-phase diode bridge rectifier. The UPQC,
carried out by using two VSIs, is shown in Fig.3: one
VSI acts as the shunt APF and the other as the series
APF. The shunt APF is realized using a three-phase,
four-leg VSI, and the series APF is carried out using
a three-phase, three-leg VSI. Both APFs share a
common dc link between them. The four-leg, VSI
based shunt active filter is capable of suppressing the
harmonics in the source currents, negative sequence
of the source current, load balancing, and powerfactor correction. The implemented control algorithm
consists mainly of the computation of the three-phase
reference
voltages
of
load
currents

for

the

and the
source

reference
current

SYSTEM CONFIGURATION

www.ijera.com

1375 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

www.ijera.com

ripple content in the series APF. A small capacity
rated R-C filter is connected in parallel with the
secondary of each series transformer to eliminate the
high switching ripple content in the series APF
injected voltage. The voltage source inverters for
both the APFs are implemented with Insulated gate
Bipolar Transistors (IGBTs). In Fig.4 (isa, isb , isc),
(ila, ilb , ilc) and (ifa, ifb , ifc,) represent the source
currents, load currents and shunt APF currents in
phase a, b and c respectively.

Fig.2 Three-phase, four wire distribution system

Fig.3 UPQC carried out by using two VSIs
The voltage at the source side before
UPQC, load voltage at the load, voltage injected by
the series APF, and dc link voltage between two
inverters are represented by vs, vL, vinj, and Vdc,
respectively. The current on the source side, current
drawn by the loads, neutral current on the source
side, load neutral current, and current injected by the
shunt APF are represented by is, il, isn, iln, and ish,
respectively.

III.

THREE PHASE FOUR WIRE
UPQC

Fig. 4 shows a 3P-4W UPQC topology,
which is feeding a combination of linear and nonlinear unbalanced load. The series and shunt APFs
are realized using two readily available three-leg
VSIs. The dc links of both APFs are connected to a
common dc link capacitor. The series APF is
connected between the supply and load terminals
using three single phase transformers with turn’s ratio
of 5:1. The primary winding of these transformer are
star connected and the secondary windings are
connected in series with the three-phase supply. In
addition to provide the required injecting voltages,
these transformers are used to filter the switching
www.ijera.com

Fig.4. Detailed configuration of proposed 3P-4W
UPQC
The source neutral current, load neutral
current and neutral current of the additional
connected transformers are represented by isn, iln
and iTn, respectively. The injected voltages by the
series APF in phase a, b and c is represented by vinja,
vinjb and vinjc, respectively. In this topology, a stardelta transformer is connected in shunt near the load
for the mitigation of the source neutral current. The
delta connected secondary provides a circulating path
to the zero sequence current (io) in case of
unbalanced load and hence the supply neutral current
is reduced to zero. The load under consideration is a
combination of linear and non-linear load. Two
single-phase R-L loads are taken as unbalanced linear
load, where as a induction motor is taken as nonlinear load.
ADVANTAGES

The reactive power is injected along with the
sinusoidal current,

The voltage and current regulation is done
effectively,

The PF is maintained even if the load is varied.

1376 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

www.ijera.com

APPLICATIONS
 Distribution Generation
 Grid Control Systems
 Transmission Lines
Series Active Filter
Dynamic Voltage Restorer is one of custom
power device specially used to maintain the load
voltage constant in the distribution system. DVR has
two operating modes. In normal operation mode it is
in standby mode in which voltage injection by DVR
is zero. Most of the time DVR will be in standby
mode and hence reduces the losses.
As soon as control circuit detects the any
voltage disturbance, reference voltage is generated
for required magnitude, duration and phase and is
injected through injection transformer. This mode of
DVR is known as injecting mode. This injection
should satisfy the equation
VL=VS+VINJ
Where VS is the source voltage, VINJ is the injected
voltage by DVR and VL is the load voltage.

Fig6: Principle of shunt active filter

IV.

MATLAB MODELING AND
SIMULATION RESULTS

Fig 7.Outer View of the system with Proposed UPQC
Fig 5 : Structure of DVR
Fig 5 shows the basic configuration and
operation of DVR which consist of an injection
transformer, Voltage Source Converter (VSC),
harmonic filter, storage device and control system
Shunt Active Filter
Nonlinear loads require harmonics current
ILH from the main supply beside fundamental current
ILF. This causes the main supply to operate at
frequencies above the nominal 50Hz or 60Hz and in
doing so, also creates a negative phase-sequence
component which is undesirable.
The shunt active filter is considered a
current source because it injects non-sinusoidal
current ILH through the parallel branch of the network
in order to compensate for the current harmonic
demand of the nonlinear load. The role of the active
filter controller is to sense and monitor the load
current and to appropriately determine the correct
reference harmonic current for the inverter. Once the
correct reference harmonic content is determined;
this reference current is fed through a suitable current
controller which then is sent to the inverter for
injection into the network. Fig 6 .shows the basic
concept and principle of shunt active filter
www.ijera.com

Fig 8.Series Compensator

Fig 9.Shunt Compensator
1377 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

www.ijera.com

Fig 10.Shunt Reference Generator

Fig 14.Shunt Filter Currents

Fig 11.Induction Motor Load

Fig.12. Voltages Before And After Compensation

Fig 15.Currents Before And After Compensation

Fig.13.Injected Voltages
www.ijera.com

1378 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

www.ijera.com

are less than 5% in the source currents and load
voltages.

REFERENCES
[1]

[2]

[3]
Fig 16.THD of Load Voltages After Compensation

[4]

[5]

[6]

[7]

[8]

Fig 17.THD of Source Currents After Compensation

V.

CONCLUSION

UPQC topology has been proposed in this
paper which has the capability to compensate voltage
sags, voltage swells and current harmonics at the load
at a lower DC-link voltage by using different control
strategies for series and shunt APF’s. The proposed
method is validated through MATLAB simulation.
The topology gives the advantages of both the neutral
clamped topology and the four leg topology. THD’s
www.ijera.com

[9]

[10]

Srinivas Bhaskar Karanki, Nagesh Geddada,
Mahesh K. Mishra, and B. Kalyan Kumar,
A Modified Three-Phase Four-Wire UPQC
Topology With Reduced DC-Link Voltage
Rating IEEE transactions on industrial
electronics, vol. 60, no. 9, September
Rosli Omar and 2N.A. Rahim 3. Voltage
Disturbances Mitigation in Low Voltage
Distribution
System
Using
New
Configuration of Dynamic Voltage Restorer
(DVR), World Applied Sciences Journal
10(12): 1480-1489, 2010 ISSN 1818-4952
IDOSI Publications, 2010
S.F.Torabi, D. Nazarpour, Y. Shayestehfard,
Compensation Of Sags And Swells Voltage
Using Dynamic Voltage Restorer (Dvr)
During Single Line To Ground And ThreePhase Faults, International Journal on
“Technical and Physical Problems of
Engineering” (IJTPE) September 2012
Issue 12 Volume 4 Number 3.
Sanjay A Deokar, Laxman M Waghmare,
DVR Control Strategy For Dynamic Power
Quality
Disturbance
Mitigation,
International Journal of Scientific and
Research Publications, Volume 2, Issue 11,
November 2012
MR. Shaktisinh N. GOHIL, 2 PROF. M. V.
MAKWANA, A Comparative Analysis of
UPQC for Power Quality Improvement,
Journal Of Information, Knowledge And
Research In Electrical Engineering ISSN:
0975 – 6736| NOV 12 TO OCT 13 |
VOLUME – 02, ISSUE - 02 .
Rosli Omar And Nasrudin Abd Rahim,
Mitigation Of Voltage Sags/Swells Using
Dynamic Voltage Restorer (Dvr), ARPN
Journal Of Engineering And Applied
Sciences, Vol. 4, No. 4, June 2009
M. Bollen, Understanding Power Quality
Problems: Voltage Sags and Interruptions.
IEEE press, New York, 1999.
S. V. R. Kumar and S. S. Nagaraju,
“Simulation of DSTATCOM and DVR in
Power Systems ,” ARPN Journal of
Engineering and Applied Science, vol. 2, no.
3, pp. 7–13, 200
Yash Pal†, A. Swarup* and Bhim Singh, A
Novel Control Strategy of Three-phase,
Four-wire UPQC for Power Quality
Improvement,
Journal
of
Electrical
Engineering & Technology Vol. 7, No. 1, pp.
1~8, 2012.
S. Srikanthan and Mahesh K. Mishra, “DC
capacitor voltage equalization in neutral
clamped
inverters
for DSTATCOM
1379 | P a g e
K. Sravani et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380

[11]

[12]

[13]

[14]

[15]

www.ijera.com

application,”
IEEE Transactions on
Industrial Electronics, vol. 57, no. 8, pp.
2768 –2775, Aug. 2010. .
B. Singh and J. Solanki, “A comparison of
control algorithms for DSTATCOM,” IEEE
Transactions on Industrial Electronics, vol.
56, no. 7, pp. 2738 –2745, July 2009
S. Rahmani, N. Mendalek, and K. AlHaddad, “Experimental design of a
nonlinear control technique for three-phase
shunt
active
power
filter,”
IEEE
Transactions on Industrial Electronics, vol.
57, no. 10, pp. 3364 –3375, Oct. 2010.
M. Kesler and E. Ozdemir, “Synchronousreference-frame-based control method for
UPQC under unbalanced and distorted load
conditions,”
IEEE
Transactions
on
Industrial Electronics, vol. 58, no. 9, pp.
3967 –3975, Sept. 2011.
V. Khadkikar and A. Chandra, “A novel
structure
for
three-phase
fourwire
distribution system utilizing unified power
quality conditioner (UPQC),”
IEEE
Transactions on Industry Applications, vol.
45, no. 5, pp. 1897 –1902, Sept.-Oct. 2009
“A new control philosophy for a unified
power quality conditioner (UPQC) to
coordinate load-reactive power demand
between shunt and series inverters,” IEEE
Transactions on Power Delivery, vol. 23, no.
4, pp. 2522 –2534, Oct. 2008.

www.ijera.com

1380 | P a g e

More Related Content

What's hot

Power Quality Enhancement Using the Interline Power Flow Controller
Power Quality Enhancement Using the Interline Power Flow ControllerPower Quality Enhancement Using the Interline Power Flow Controller
Power Quality Enhancement Using the Interline Power Flow ControllerIJPEDS-IAES
 
A Novel Multi Port Dc/Dc Converter Topology Using Zero Voltage Switching For...
A Novel Multi Port Dc/Dc Converter Topology Using Zero  Voltage Switching For...A Novel Multi Port Dc/Dc Converter Topology Using Zero  Voltage Switching For...
A Novel Multi Port Dc/Dc Converter Topology Using Zero Voltage Switching For...IJMER
 
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...IAES-IJPEDS
 
Analysis and hardware implementation of five level cascaded H Bridge inverter
Analysis and hardware implementation of five level cascaded H Bridge inverterAnalysis and hardware implementation of five level cascaded H Bridge inverter
Analysis and hardware implementation of five level cascaded H Bridge inverterIJERA Editor
 
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...IJECEIAES
 
Load flow study Part-II
Load flow study Part-IILoad flow study Part-II
Load flow study Part-IIAsif Jamadar
 
power flow and optimal power flow
power flow and optimal power flowpower flow and optimal power flow
power flow and optimal power flowAhmed M. Elkholy
 
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerAugmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerIJERA Editor
 
Development of a Novel Three Phase Grid-Tied Multilevel Inverter Topology
Development of a Novel Three Phase Grid-Tied Multilevel Inverter TopologyDevelopment of a Novel Three Phase Grid-Tied Multilevel Inverter Topology
Development of a Novel Three Phase Grid-Tied Multilevel Inverter TopologyIAES-IJPEDS
 
Bi directional dc to dc converters for fuel cell systems
Bi directional dc to dc converters for fuel cell systemsBi directional dc to dc converters for fuel cell systems
Bi directional dc to dc converters for fuel cell systemsLi (Eric) Sun
 

What's hot (20)

Power flow analysis
Power flow analysisPower flow analysis
Power flow analysis
 
Power Quality Enhancement Using the Interline Power Flow Controller
Power Quality Enhancement Using the Interline Power Flow ControllerPower Quality Enhancement Using the Interline Power Flow Controller
Power Quality Enhancement Using the Interline Power Flow Controller
 
load flow 1
 load flow 1 load flow 1
load flow 1
 
I41045662
I41045662I41045662
I41045662
 
A Novel Multi Port Dc/Dc Converter Topology Using Zero Voltage Switching For...
A Novel Multi Port Dc/Dc Converter Topology Using Zero  Voltage Switching For...A Novel Multi Port Dc/Dc Converter Topology Using Zero  Voltage Switching For...
A Novel Multi Port Dc/Dc Converter Topology Using Zero Voltage Switching For...
 
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...
Asymmetrical Cascaded Multi Level Inverter using Control Freedom Pulse width ...
 
Load flow study
Load flow studyLoad flow study
Load flow study
 
[IJET-V2I3P17] Authors: R.C.Rohini, G.Srividhya
[IJET-V2I3P17] Authors: R.C.Rohini, G.Srividhya[IJET-V2I3P17] Authors: R.C.Rohini, G.Srividhya
[IJET-V2I3P17] Authors: R.C.Rohini, G.Srividhya
 
Analysis and hardware implementation of five level cascaded H Bridge inverter
Analysis and hardware implementation of five level cascaded H Bridge inverterAnalysis and hardware implementation of five level cascaded H Bridge inverter
Analysis and hardware implementation of five level cascaded H Bridge inverter
 
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...
dSPACE Implementation for a Fuzzy Logic Voltage Control using a Self-Excited ...
 
Load flow study Part-II
Load flow study Part-IILoad flow study Part-II
Load flow study Part-II
 
Structure of power system
Structure of power systemStructure of power system
Structure of power system
 
Lz3620532059
Lz3620532059Lz3620532059
Lz3620532059
 
power flow and optimal power flow
power flow and optimal power flowpower flow and optimal power flow
power flow and optimal power flow
 
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerAugmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
 
[IJET V2I2P30] Authors: AnkurGheewala, Jay Chanawala,Nikhil Jadav,Modi Rishit...
[IJET V2I2P30] Authors: AnkurGheewala, Jay Chanawala,Nikhil Jadav,Modi Rishit...[IJET V2I2P30] Authors: AnkurGheewala, Jay Chanawala,Nikhil Jadav,Modi Rishit...
[IJET V2I2P30] Authors: AnkurGheewala, Jay Chanawala,Nikhil Jadav,Modi Rishit...
 
A380114
A380114A380114
A380114
 
Development of a Novel Three Phase Grid-Tied Multilevel Inverter Topology
Development of a Novel Three Phase Grid-Tied Multilevel Inverter TopologyDevelopment of a Novel Three Phase Grid-Tied Multilevel Inverter Topology
Development of a Novel Three Phase Grid-Tied Multilevel Inverter Topology
 
A Repetitive Sparce Matrix Converter with Z-Source Network to having less Cur...
A Repetitive Sparce Matrix Converter with Z-Source Network to having less Cur...A Repetitive Sparce Matrix Converter with Z-Source Network to having less Cur...
A Repetitive Sparce Matrix Converter with Z-Source Network to having less Cur...
 
Bi directional dc to dc converters for fuel cell systems
Bi directional dc to dc converters for fuel cell systemsBi directional dc to dc converters for fuel cell systems
Bi directional dc to dc converters for fuel cell systems
 

Viewers also liked

Viewers also liked (20)

Ia3613981403
Ia3613981403Ia3613981403
Ia3613981403
 
Hw3613811385
Hw3613811385Hw3613811385
Hw3613811385
 
Hs3613611366
Hs3613611366Hs3613611366
Hs3613611366
 
Ht3613671371
Ht3613671371Ht3613671371
Ht3613671371
 
Jx3617151720
Jx3617151720Jx3617151720
Jx3617151720
 
Ig3614301436
Ig3614301436Ig3614301436
Ig3614301436
 
If3614251429
If3614251429If3614251429
If3614251429
 
Hr3613551360
Hr3613551360Hr3613551360
Hr3613551360
 
Hm3613211331
Hm3613211331Hm3613211331
Hm3613211331
 
Hq3613511354
Hq3613511354Hq3613511354
Hq3613511354
 
Hp3613441350
Hp3613441350Hp3613441350
Hp3613441350
 
Nathan mag covers
Nathan mag coversNathan mag covers
Nathan mag covers
 
Fracturas tipos
Fracturas tiposFracturas tipos
Fracturas tipos
 
Maria Tornberg Professional resume
Maria Tornberg Professional resumeMaria Tornberg Professional resume
Maria Tornberg Professional resume
 
When is GM going to pay US back, since we own 60.8% of GM aka ObamaMotors?
When is GM going to pay US back, since we own 60.8% of GM aka ObamaMotors?When is GM going to pay US back, since we own 60.8% of GM aka ObamaMotors?
When is GM going to pay US back, since we own 60.8% of GM aka ObamaMotors?
 
Iglesia
IglesiaIglesia
Iglesia
 
Encuesta de los que elegimos
Encuesta de los que elegimosEncuesta de los que elegimos
Encuesta de los que elegimos
 
αιτηση επανασυνδεσης
αιτηση επανασυνδεσηςαιτηση επανασυνδεσης
αιτηση επανασυνδεσης
 
Git 实战
Git 实战Git 实战
Git 实战
 
Chao clandestino.blog de hispanistas de agadir
Chao clandestino.blog de hispanistas de agadirChao clandestino.blog de hispanistas de agadir
Chao clandestino.blog de hispanistas de agadir
 

Similar to Hv3613741380

Modified three phase Unified Power Quality Conditioner with capacitor midpoin...
Modified three phase Unified Power Quality Conditioner with capacitor midpoin...Modified three phase Unified Power Quality Conditioner with capacitor midpoin...
Modified three phase Unified Power Quality Conditioner with capacitor midpoin...IOSR Journals
 
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of Controls
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of ControlsCascaded Multilevel Inverter Based Active Power Filters: A Survey of Controls
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of ControlsIOSR Journals
 
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...IJMER
 
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...IJITE
 
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...IOSR Journals
 
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...IJMTST Journal
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...Transient Stability Enhancement of a Multi-Machine System using Particle Swar...
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...IJERA Editor
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 
1_Intro + Per Unit.pdf
1_Intro + Per Unit.pdf1_Intro + Per Unit.pdf
1_Intro + Per Unit.pdfLiewChiaPing
 
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...IJPEDS-IAES
 
Simulation Of Interline Power Flow Controller in Power Transmission System
 Simulation Of Interline Power Flow Controller in Power Transmission System Simulation Of Interline Power Flow Controller in Power Transmission System
Simulation Of Interline Power Flow Controller in Power Transmission Systemijsrd.com
 
Comparative Analysis of Power Quality Enhancement of Distribution System usin...
Comparative Analysis of Power Quality Enhancement of Distribution System usin...Comparative Analysis of Power Quality Enhancement of Distribution System usin...
Comparative Analysis of Power Quality Enhancement of Distribution System usin...IRJET Journal
 
Simulation and Performance Investigation of Unified Power Quality Conditioner...
Simulation and Performance Investigation of Unified Power Quality Conditioner...Simulation and Performance Investigation of Unified Power Quality Conditioner...
Simulation and Performance Investigation of Unified Power Quality Conditioner...Dr. Sudhir Kumar Srivastava
 
Ee 1351 power system analysis
Ee 1351 power system analysisEe 1351 power system analysis
Ee 1351 power system analysisHari Kumar
 

Similar to Hv3613741380 (20)

Modified three phase Unified Power Quality Conditioner with capacitor midpoin...
Modified three phase Unified Power Quality Conditioner with capacitor midpoin...Modified three phase Unified Power Quality Conditioner with capacitor midpoin...
Modified three phase Unified Power Quality Conditioner with capacitor midpoin...
 
Reduction of single DC bus capacitance in photovoltaic cascaded multilevel co...
Reduction of single DC bus capacitance in photovoltaic cascaded multilevel co...Reduction of single DC bus capacitance in photovoltaic cascaded multilevel co...
Reduction of single DC bus capacitance in photovoltaic cascaded multilevel co...
 
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of Controls
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of ControlsCascaded Multilevel Inverter Based Active Power Filters: A Survey of Controls
Cascaded Multilevel Inverter Based Active Power Filters: A Survey of Controls
 
An Analysis of Virtual Flux Direct Power Control of Three-Phase AC-DC Converter
An Analysis of Virtual Flux Direct Power Control of Three-Phase AC-DC ConverterAn Analysis of Virtual Flux Direct Power Control of Three-Phase AC-DC Converter
An Analysis of Virtual Flux Direct Power Control of Three-Phase AC-DC Converter
 
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
 
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...
POWER STABILITY ANALYSIS OF A TRANSMISSION SYSTEM WITH A UNIFIED POWER FLOW C...
 
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
Modified One Cycle Controlled Scheme for Single-Phase Grid Connected Pv-Fc Hy...
 
B360614
B360614B360614
B360614
 
Gran importancia
Gran importanciaGran importancia
Gran importancia
 
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...
A New Topology for Power Quality Improvement using 3-Phase 4-Wire UPQC with R...
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
 
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...Transient Stability Enhancement of a Multi-Machine System using Particle Swar...
Transient Stability Enhancement of a Multi-Machine System using Particle Swar...
 
SD8_12_Alok Jain.ppt
SD8_12_Alok Jain.pptSD8_12_Alok Jain.ppt
SD8_12_Alok Jain.ppt
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
1_Intro + Per Unit.pdf
1_Intro + Per Unit.pdf1_Intro + Per Unit.pdf
1_Intro + Per Unit.pdf
 
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...
An Experimental Study of the Unbalance Compensation by Voltage Source Inverte...
 
Simulation Of Interline Power Flow Controller in Power Transmission System
 Simulation Of Interline Power Flow Controller in Power Transmission System Simulation Of Interline Power Flow Controller in Power Transmission System
Simulation Of Interline Power Flow Controller in Power Transmission System
 
Comparative Analysis of Power Quality Enhancement of Distribution System usin...
Comparative Analysis of Power Quality Enhancement of Distribution System usin...Comparative Analysis of Power Quality Enhancement of Distribution System usin...
Comparative Analysis of Power Quality Enhancement of Distribution System usin...
 
Simulation and Performance Investigation of Unified Power Quality Conditioner...
Simulation and Performance Investigation of Unified Power Quality Conditioner...Simulation and Performance Investigation of Unified Power Quality Conditioner...
Simulation and Performance Investigation of Unified Power Quality Conditioner...
 
Ee 1351 power system analysis
Ee 1351 power system analysisEe 1351 power system analysis
Ee 1351 power system analysis
 

Recently uploaded

Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...lizamodels9
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst SummitHolger Mueller
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsApsara Of India
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessSeta Wicaksana
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menzaictsugar
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCRashishs7044
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadAyesha Khan
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCRashishs7044
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCRashishs7044
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCRsoniya singh
 
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts ServiceVip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Serviceankitnayak356677
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607dollysharma2066
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncrdollysharma2066
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Servicecallgirls2057
 

Recently uploaded (20)

Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst Summit
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful Business
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
(8264348440) 🔝 Call Girls In Mahipalpur 🔝 Delhi NCR
 
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts ServiceVip Female Escorts Noida 9711199171 Greater Noida Escorts Service
Vip Female Escorts Noida 9711199171 Greater Noida Escorts Service
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort ServiceCall US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
Call US-88OO1O2216 Call Girls In Mahipalpur Female Escort Service
 

Hv3613741380

  • 1. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 RESEARCH ARTICLE www.ijera.com OPEN ACCESS UPQC for Power Quality Improvement of Induction Motor Drive with Reduced DC Link Voltage K. Sravani, T. Subramanya Sastry M-tech Student Scholar Department of Electrical & Electronics Engineering, JBIET Engineering College, Moinabad;RR(Dt); A.P, India. Associate Professor Department of Electrical & Electronics Engineering, JBIET Engineering College, Moinabad;RR(Dt); A.P, India. Abstract The main aim of this project is ,this topology enables UPQC to have a reduced dc-link voltage without compromising its compensation capability. Three-phase, four-wire unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage Source Inverter (VSI), The performance of the applied control algorithm is evaluated in terms of power-factor correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. This circuit consists of capacitor in series with the interfacing inductor of the shunt active filter. The series capacitor enables reduction in dc-link voltage requirement of the shunt active filter and simultaneously compensating the reactive power required by the load, so as to maintain unity power factor, without compromising its performance. This allows us to match the dc-link voltage requirements of the series and shunt active filters with a common dc-link capacitor. AC induction motor has a fixed in the output side to run the ac machine with required speed. The proposed topology enables UPQC to compensate voltage sags, voltage swells and current harmonics with a reduced DC-link voltage without compromising its compensation capability by implementing the circuit in MATLAB/SIMULINK software. Index Terms: Power quality, UPQC, Load balancing, voltage sags, voltage swells, AC Induction motor, APF I. INTRODUCTION This proposed topology also helps to match the dc-link voltage requirement of the shunt and series active filters of the UPQC. The topology uses a capacitor in series with the interfacing inductor of the shunt active filter, and the system neutral is connected to the negative terminal of the dc-link voltage to avoid the requirement of the fourth leg in the voltage source inverter (VSI) of the shunt active filter. The average switching frequency of the switches in the VSI also reduces; consequently the switching losses in the inverters reduce. The main aim of this project this topology enables UPQC to have a reduced dc-link voltage without compromising its compensation capability. The three phase three wires UPQC system is used for compensation of power quality issues. In this method the UPQC which requires more rating of series and shunt active filters. Additionally to maintain the Low harmonics level by adding passive filters. The different topologies reported in literature of three-phase four-wire UPQC use active compensation for the mitigation of source neutral current along with other PQ problems. For the mitigation of source neutral current, the uses of passive elements are advantageous over the active compensation due to ruggedness and less complexity. There are many techniques proposed for the www.ijera.com compensation of neutral current using star-delta transformer in a three-phase four-wire distribution system and some of these have been patented. The application of star-delta transformer along with an APF is also used for harmonic current reduction in the neutral conductor. A filter employing three singlephase transformers with a capacitor has been used for removing harmonic current from the neutral conductor and has been patented. Another scheme by providing a six-phase system, with the help of two transformers connected in anti-phase has been reported for canceling third harmonic current in neutral conductor. The star-delta transformer along with a diode rectifier and a half-bridge PWM inverter is also reported for the compensation of neutral current. For the mitigation of source neutral current along with other current based distortions, the integration of readily available three-leg VSI with star-delta transformer has been reported in literature for 3P-4W DSTATCOM [6]. Unfortunately, for the mitigation of neutral current the performance of the star-delta transformers is affected to an extent under distorted or unbalanced source voltages, which is very common in practice. The UPQC is one of the key CPDs, which takes care of both voltage and current based distortions simultaneously. Hence, for neutral current mitigation the integration of star-delta transformer with UPQC is 1374 | P a g e
  • 2. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 more justified. In this paper, a simple star-delta configuration is utilized for the mitigation of source neutral current, while other options such as zig-zag www.ijera.com transformer or T-connected transformer specially designed transformers. require Fig.1. Equivalent circuit of neutral-clamped VSI topology-based UPQC The conventional and proposed topology of the UPQC are discussed in detail. Fig. 1 shows the power circuit of the neutral-clamped VSI topologybased UPQC which is considered as the conventional topology in this study. Even though this topology requires two dc storage devices, each leg of the VSI can be controlled independently, and tracking is smooth with less number of switches when compared to other VSI topologies. In this figure, vsa, vsb, and vsc are source voltages of phases a, b, and c, respectively. Similarly, vta, vtb, and vtc are terminal voltages. The voltages vdvra, vdvrb, and vdvrc are injected by the series active filter. The threephase source currents are represented by isa, isb, and isc, load currents are represented by ila, ilb, and ilc. The shunt active filter currents are denoted by ifa, ifb, ifc, and iln represents the current in the neutral leg. Ls and Rs represent the feeder inductance and resistance, respectively. The interfacing inductance and resistance of the shunt active filter are represented by Lf and Rf , respectively, and the interfacing inductance and filter capacitor of the series active filter are represented by Lse and Cse, respectively. The load constituted of both linear and nonlinear loads as shown in this figure. The dc-link capacitors and voltages across them are represented by Cdc1 = Cdc2 = Cdc and Vdc1 = Vdc2 = Vdc, respectively, and the total dc-link voltage is represented by Vdbus(Vdc1 + Vdc2 = 2Vdc). II. The system under consideration for threephase, four wire distribution system is shown in Fig. 2.The UPQC is connected before the load to make the source and the load voltage free from any distortions. At the same time, the reactive current drawn from the source should be such that the currents at source side would be in phase with utility voltages. Provision is made to realize voltage harmonics in the source voltage by switching on/off the three-phase diode bridge rectifier. The UPQC, carried out by using two VSIs, is shown in Fig.3: one VSI acts as the shunt APF and the other as the series APF. The shunt APF is realized using a three-phase, four-leg VSI, and the series APF is carried out using a three-phase, three-leg VSI. Both APFs share a common dc link between them. The four-leg, VSI based shunt active filter is capable of suppressing the harmonics in the source currents, negative sequence of the source current, load balancing, and powerfactor correction. The implemented control algorithm consists mainly of the computation of the three-phase reference voltages of load currents for the and the source reference current SYSTEM CONFIGURATION www.ijera.com 1375 | P a g e
  • 3. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 www.ijera.com ripple content in the series APF. A small capacity rated R-C filter is connected in parallel with the secondary of each series transformer to eliminate the high switching ripple content in the series APF injected voltage. The voltage source inverters for both the APFs are implemented with Insulated gate Bipolar Transistors (IGBTs). In Fig.4 (isa, isb , isc), (ila, ilb , ilc) and (ifa, ifb , ifc,) represent the source currents, load currents and shunt APF currents in phase a, b and c respectively. Fig.2 Three-phase, four wire distribution system Fig.3 UPQC carried out by using two VSIs The voltage at the source side before UPQC, load voltage at the load, voltage injected by the series APF, and dc link voltage between two inverters are represented by vs, vL, vinj, and Vdc, respectively. The current on the source side, current drawn by the loads, neutral current on the source side, load neutral current, and current injected by the shunt APF are represented by is, il, isn, iln, and ish, respectively. III. THREE PHASE FOUR WIRE UPQC Fig. 4 shows a 3P-4W UPQC topology, which is feeding a combination of linear and nonlinear unbalanced load. The series and shunt APFs are realized using two readily available three-leg VSIs. The dc links of both APFs are connected to a common dc link capacitor. The series APF is connected between the supply and load terminals using three single phase transformers with turn’s ratio of 5:1. The primary winding of these transformer are star connected and the secondary windings are connected in series with the three-phase supply. In addition to provide the required injecting voltages, these transformers are used to filter the switching www.ijera.com Fig.4. Detailed configuration of proposed 3P-4W UPQC The source neutral current, load neutral current and neutral current of the additional connected transformers are represented by isn, iln and iTn, respectively. The injected voltages by the series APF in phase a, b and c is represented by vinja, vinjb and vinjc, respectively. In this topology, a stardelta transformer is connected in shunt near the load for the mitigation of the source neutral current. The delta connected secondary provides a circulating path to the zero sequence current (io) in case of unbalanced load and hence the supply neutral current is reduced to zero. The load under consideration is a combination of linear and non-linear load. Two single-phase R-L loads are taken as unbalanced linear load, where as a induction motor is taken as nonlinear load. ADVANTAGES  The reactive power is injected along with the sinusoidal current,  The voltage and current regulation is done effectively,  The PF is maintained even if the load is varied. 1376 | P a g e
  • 4. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 www.ijera.com APPLICATIONS  Distribution Generation  Grid Control Systems  Transmission Lines Series Active Filter Dynamic Voltage Restorer is one of custom power device specially used to maintain the load voltage constant in the distribution system. DVR has two operating modes. In normal operation mode it is in standby mode in which voltage injection by DVR is zero. Most of the time DVR will be in standby mode and hence reduces the losses. As soon as control circuit detects the any voltage disturbance, reference voltage is generated for required magnitude, duration and phase and is injected through injection transformer. This mode of DVR is known as injecting mode. This injection should satisfy the equation VL=VS+VINJ Where VS is the source voltage, VINJ is the injected voltage by DVR and VL is the load voltage. Fig6: Principle of shunt active filter IV. MATLAB MODELING AND SIMULATION RESULTS Fig 7.Outer View of the system with Proposed UPQC Fig 5 : Structure of DVR Fig 5 shows the basic configuration and operation of DVR which consist of an injection transformer, Voltage Source Converter (VSC), harmonic filter, storage device and control system Shunt Active Filter Nonlinear loads require harmonics current ILH from the main supply beside fundamental current ILF. This causes the main supply to operate at frequencies above the nominal 50Hz or 60Hz and in doing so, also creates a negative phase-sequence component which is undesirable. The shunt active filter is considered a current source because it injects non-sinusoidal current ILH through the parallel branch of the network in order to compensate for the current harmonic demand of the nonlinear load. The role of the active filter controller is to sense and monitor the load current and to appropriately determine the correct reference harmonic current for the inverter. Once the correct reference harmonic content is determined; this reference current is fed through a suitable current controller which then is sent to the inverter for injection into the network. Fig 6 .shows the basic concept and principle of shunt active filter www.ijera.com Fig 8.Series Compensator Fig 9.Shunt Compensator 1377 | P a g e
  • 5. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 www.ijera.com Fig 10.Shunt Reference Generator Fig 14.Shunt Filter Currents Fig 11.Induction Motor Load Fig.12. Voltages Before And After Compensation Fig 15.Currents Before And After Compensation Fig.13.Injected Voltages www.ijera.com 1378 | P a g e
  • 6. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 www.ijera.com are less than 5% in the source currents and load voltages. REFERENCES [1] [2] [3] Fig 16.THD of Load Voltages After Compensation [4] [5] [6] [7] [8] Fig 17.THD of Source Currents After Compensation V. CONCLUSION UPQC topology has been proposed in this paper which has the capability to compensate voltage sags, voltage swells and current harmonics at the load at a lower DC-link voltage by using different control strategies for series and shunt APF’s. The proposed method is validated through MATLAB simulation. The topology gives the advantages of both the neutral clamped topology and the four leg topology. THD’s www.ijera.com [9] [10] Srinivas Bhaskar Karanki, Nagesh Geddada, Mahesh K. Mishra, and B. Kalyan Kumar, A Modified Three-Phase Four-Wire UPQC Topology With Reduced DC-Link Voltage Rating IEEE transactions on industrial electronics, vol. 60, no. 9, September Rosli Omar and 2N.A. Rahim 3. Voltage Disturbances Mitigation in Low Voltage Distribution System Using New Configuration of Dynamic Voltage Restorer (DVR), World Applied Sciences Journal 10(12): 1480-1489, 2010 ISSN 1818-4952 IDOSI Publications, 2010 S.F.Torabi, D. Nazarpour, Y. Shayestehfard, Compensation Of Sags And Swells Voltage Using Dynamic Voltage Restorer (Dvr) During Single Line To Ground And ThreePhase Faults, International Journal on “Technical and Physical Problems of Engineering” (IJTPE) September 2012 Issue 12 Volume 4 Number 3. Sanjay A Deokar, Laxman M Waghmare, DVR Control Strategy For Dynamic Power Quality Disturbance Mitigation, International Journal of Scientific and Research Publications, Volume 2, Issue 11, November 2012 MR. Shaktisinh N. GOHIL, 2 PROF. M. V. MAKWANA, A Comparative Analysis of UPQC for Power Quality Improvement, Journal Of Information, Knowledge And Research In Electrical Engineering ISSN: 0975 – 6736| NOV 12 TO OCT 13 | VOLUME – 02, ISSUE - 02 . Rosli Omar And Nasrudin Abd Rahim, Mitigation Of Voltage Sags/Swells Using Dynamic Voltage Restorer (Dvr), ARPN Journal Of Engineering And Applied Sciences, Vol. 4, No. 4, June 2009 M. Bollen, Understanding Power Quality Problems: Voltage Sags and Interruptions. IEEE press, New York, 1999. S. V. R. Kumar and S. S. Nagaraju, “Simulation of DSTATCOM and DVR in Power Systems ,” ARPN Journal of Engineering and Applied Science, vol. 2, no. 3, pp. 7–13, 200 Yash Pal†, A. Swarup* and Bhim Singh, A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement, Journal of Electrical Engineering & Technology Vol. 7, No. 1, pp. 1~8, 2012. S. Srikanthan and Mahesh K. Mishra, “DC capacitor voltage equalization in neutral clamped inverters for DSTATCOM 1379 | P a g e
  • 7. K. Sravani et al Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1374-1380 [11] [12] [13] [14] [15] www.ijera.com application,” IEEE Transactions on Industrial Electronics, vol. 57, no. 8, pp. 2768 –2775, Aug. 2010. . B. Singh and J. Solanki, “A comparison of control algorithms for DSTATCOM,” IEEE Transactions on Industrial Electronics, vol. 56, no. 7, pp. 2738 –2745, July 2009 S. Rahmani, N. Mendalek, and K. AlHaddad, “Experimental design of a nonlinear control technique for three-phase shunt active power filter,” IEEE Transactions on Industrial Electronics, vol. 57, no. 10, pp. 3364 –3375, Oct. 2010. M. Kesler and E. Ozdemir, “Synchronousreference-frame-based control method for UPQC under unbalanced and distorted load conditions,” IEEE Transactions on Industrial Electronics, vol. 58, no. 9, pp. 3967 –3975, Sept. 2011. V. Khadkikar and A. Chandra, “A novel structure for three-phase fourwire distribution system utilizing unified power quality conditioner (UPQC),” IEEE Transactions on Industry Applications, vol. 45, no. 5, pp. 1897 –1902, Sept.-Oct. 2009 “A new control philosophy for a unified power quality conditioner (UPQC) to coordinate load-reactive power demand between shunt and series inverters,” IEEE Transactions on Power Delivery, vol. 23, no. 4, pp. 2522 –2534, Oct. 2008. www.ijera.com 1380 | P a g e