AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 45 | P a g e
Comparative study of Performance of RCC Multi-Storey
Building for Koyna and Bhuj Earthquakes
Atul N.Kolekar1
, Y.P.Pawar2
, Dr. C. P. Pise3,
D. D. Mohite2
, S. S. Kadam2
,
C. M. Deshmukh2
.
P.G. Student, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India1
Assistant Professor, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India2
Associate Professor and HOD, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India3
ABSTRACT
The recent history of earthquakes have indicated that if the structures are not properly designed and constructed
with required quality may cause great damage to structures. This fact has resulted in to ensure safety against
earthquake forces of tall structures hence, there is need to determine seismic responses of such building for
designing earthquake resistant structures by carrying seismic analysis of structure. In the present work dynamic
analysis of G+12 RC multi-storied framed building considering for Koyna and Bhuj earthquake is carried out by
response spectrum analysis and time history analysis and responses of such building are comparatively studied
with the help of SAP2000 software. Two time histories (i.e. koyna and Bhuj) have been used to develop
different acceptable criteria (base shear, storey displacement, storey drift). From the results it is recommended
that time history analysis should be performed as it predicts the structural response more accurately than the
response spectrum analysis. Pushover Analysis is also performed for the same building and from results it is
found that building is seismically safe.
Keywords—SAP2000, Response Spectrum Analysis, Seismic Responses, Time History Analysis,Pushover
Analysis.
I. I .INTRODUCTION
The process of urbanization has been a
common feature throughout the centuries,
Globalization and Growth of high rise buildings is
the need of current population, earthquakes have the
potential for causing the greatest damages to those
tall structures. Hence, it is important to take in to
account the seismic load for the design of high-rise
structure. Earthquakes occurred in recent past,
particularly in the state of Gujarat (Bhuj, 2001) have
indicated that if the structures are not properly
designed and constructed with required quality may
cause great damage to structures and also loss of life.
Reinforced concrete buildings have been destructed
on a very large scale in Bhuj earthquake of Jan 26th
2001, Even though these buildings are analyzed and
designed as per IS code. The damages are caused by
inconsistent seismic response, irregularity in mass
and plan, soft storey and floating column etc. Hence
it becomes necessary to determine actual seismic
performance of building subjected to seismic forces.
Time history analysis gives more realistic behavior
of the building. It gives more accurately seismic
responses than response spectrum analysis because
of it includes material nonlinearity and dynamic
nature of earthquake.
Patil A. S. and Kumbhar P. D. [1] analyzed
ten storied RC building considering different seismic
intensities and seismic responses of such building
are evaluated with the help of SAP2000 software.
Five different time histories have been used
considering seismic intensities V, VI, VII, VIII, IX
and X for establishment of relationship between
seismic intensities and seismic responses. From the
study it is recommended that, to ensure safety
against earthquake force, analysis of multistoried RC
building using Time History method becomes
necessary.
Prashanth P. et al. [2] designed multi storey
buildings with regular and irregular plan (as per IS
1893) using STAAD Pro and ETABS software
separately. From the design results of beams, we
may conclude that ETABS gave lesser area of
required steel as compared to STAAD Pro. Form the
design results of column; since the required steel for
the column forces in this particular problem is less
than the minimum steel limit of column (i.e., 0.8%),
the amount of steel calculated by both the software
is equal.
Wakchaure M. R. and Ped S. P. [3] studied
the effect of masonry walls on high rise building.
Linear dynamic analysis on high rise building with
different arrangement was carried out. Earthquake
time history is applied to the models. The width of
strut was calculated by using equivalent strut
method. All analysis was carried out by software
ETABS. Base shear, storey displacement, story drift
RESEARCH ARTICLE OPEN ACCESS
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 46 | P a g e
was calculated and compared for all models. The
results showed that infill walls reduce
displacements, time period and increases base shear.
Parvathaneni S. and Elavenil S. [4] done the
three dimensional RC frames analysis for gravity
loads and lateral loads and the response spectrum
analysis and time history analysis carried out to
evaluate seismic performance of frame. The
response spectrum analysis and time-history analysis
is done by using ETABS with compatible
accelograms, and results obtained from analysis are
verified. Nonlinear time history analysis is done for
studying the inelastic behavior of the structures.
Bahador et al. [5] studied Multi-storey
irregular buildings with 20 stories using software
packages ETABS and SAP 2000 for seismic zone V
in India. The investigation of dynamic responses of
building under actual earthquakes considering EL-
CENTRO 1949 and CHI-CHI Taiwan 1999 were
done. They highlighted the exactness and accuracy
of Time History analysis in comparison with the
most commonly adopted Response Spectrum
Analysis and Equivalent Static Analysis.
N.M.Nikam [20]considered G+15and G+20
storied building with provision of shear wall at
different position and pushover analysisis carried
out.They found that fundamental time period is
increased due to provision of shear wall as well as
global stiffness is increases.
MohommadAzoz and AnshulR.Nikhade
[21] studied pushover analysis on reinforced
concrete structure in which G+10 building was
subjected to push in X direction and push in Y
direction. Analysis was done in sap2000 15.They
found that slope of pushover curve is gradually
changed with increase of the lateral displacement of
the building. From results the concluded that the
building considered for analysis not requires
retrofitting.
II. OBJECTIVES
1. To analyze the RCC multistory building for
seismic forces.
2. To evaluate various responses such as base
shear, lateral displacement, storey drift etc. of
building for Koyna and Bhuj earthquakes.
3. To compare effect of Koyna and Bhuj
earthquakes on performance of RCC multistory
building.
4. To compare software results with current
practices.
5. To investigate material non-linearity behaviour
considering plastic analysis.
III. METHODS OF ANALYSIS:
A. Equivalent Static Analysis
All design against seismic loads must
consider the dynamic nature of the load. However,
for simple regular structures, analysis by equivalent
linear static methods is insufficient. This is permitted
in most codes of practice for regular, low- to
medium-rise buildings. This procedure takes into
account the dynamic behavior of building in an
approximate manner; it does not require dynamic
analysis. The static method is based on the
formulation given in IS codes thus it is easiest one
and requires less computational efforts. First, the
design base shear is computed for the whole
building, and it is then distributed along the height of
the building. The lateral forces at each floor levels
thus obtained are distributed to individual’s lateral
load resisting elements.[3,5]
B. Response Spectrum Method
Response spectrum method is the linear
dynamic analysis method. In this method the peak
structural response can be obtained directly during
an earthquake using the earthquake responses (or
design) spectrum. It represents the maximum
responses of idealized SDOF systems with certain
time period and modal damping, during earthquake
ground motion. The maximum response curve is
plotted for various damping values and against the
undamped natural period, and can be represented in
terms of maximum relative displacement or
maximum relative velocity.[5,9,10,11,15,16]
C. Time History Method
Time History method is step by step
analysis of the dynamic response of the structure at
each time increment when its base is subjected to
ground motion time history record. To perform such
an analysis a representative earthquake time history
is essential for a structure being evaluated. It is used
to determine the seismic response of a structure
under dynamic loading of considered earthquake.[1,
4, 14, 18]
D. Pushover Analysis
Pushover analysis is a static non-linear
procedure of analysis of building where loading is
goes on increasing with certain predefined pattern.
The structure is pushed until a collapse mechanism
is developed. With increase in magnitude of loads
weak links and failure modes of building are found.
The pushover analysis is used to get the relation
between base shear and roof displacement. I.e.
Pushover curve.[20,21,22]
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 47 | P a g e
IV. STRUCTURAL MODELING AND
ANALYSIS :
The G+12 RC multistory framed building
considered for analysis to know the realistic
behavior during earthquake with the general form of
plan shown in fig 1. RC multi-storey framed
building is modeled for two time histories i.e. Bhuj
and Koyna. Plan dimensions in X and Y direction
are 20m and 20m respectively. The buildings are
consisting of columns with dimension 600mm x
600mm for all stories and beam with dimension
300mm x 700mm. the floor slabs are taken as
150mm thick. The height of all floors is 3.2m and
height of plinth is 2m. soil type is Medium. Modal
damping 5% is assumed with SMRF and I=1. The
columns are assumed to be fixed at the base.
Material concrete grade is M30 and while steel
Fe415 is used.
Fig. 1 Plan and Elevation of G+12 RC multistoried framed Building in SAP2000
V. RESULT AND DISCUSSION:
The comparative study of storey
displacement, base shear and storey drift of
building in different stories by response spectrum
analysis and time history analysis for
Koyna&Bhujis performed here. The results
obtained from analysis are given below and
comparative study is carried out as follows
D. Comparison of Base Shear:
Table 1: comparison of story shear for earthquake by RSM and THM
Story level
(mm)
Story shear (kN)
Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM
43600 275.137 340.344 377.016 510.517
40400 611.824 759.264 819.801 1138.897
37200 893.170 1114.448 1283.648 1671.674
34000 1254.304 1441.154 1650.849 2116.733
30800 1504.689 1654.638 1910.848 2481.958
27600 1830.732 1850.156 2022.298 2775.235
24400 2138.652 2002.965 2394.417 3004.448
21200 2315.940 2118.321 2777.447 3177.482
18000 2432.479 2201.481 2968.719 3302.222
14800 2508.256 2257.701 2956.351 3386.552
11600 2366.272 2292.238 2818.154 3438.357
8400 1962.451 2310.348 2646.438 3465.523
5200 1566.039 2317.288 2508.267 3475.933
2000 1691.523 2317.387 2460.222 3476.294
0 1691.523 2317.387 2460.222 3476.294
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 48 | P a g e
Fig. 2 Comparison of Base Shear for Koyna&Bhuj Earthquake by THM&RSM
By Time History method base shear are 1691.523
kN for Koynaand forBhuj 2460.222kN and by
Response Spectrum Method values of base shear
are2317.387kN for Koyna and 3476.294kN for
Bhuj earthquake
.
E. Storey Displacements:
Table 2: Comparison of story displacement for earthquake by RSM and THM
Story level
(mm)
Story displacement (mm)
Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM
0 0 0 0 0
2000 0.681 0.734 0.492 1.102
5200 3.077 3.527 2.451 5.291
8400 5.497 6.653 4.732 9.982
11600 7.714 9.707 7.038 14.562
14800 9.415 12.623 9.252 18.901
18000 11.589 15.304 11.291 22.957
21200 13.503 17.819 14.017 26.717
24400 15.198 20.115 17.484 30.174
27600 16.898 22.209 20.939 33.315
34000 20.063 25.691 27.404 38.538
37200 21.187 27.012 29.980 40.521
40400 21.347 28.004 31.827 42.009
43600 21.528 28.665 32.026 43.001
Fig. 3 Comparison of storey displacement for Earthquakes using RSM&THM
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 49 | P a g e
It has been observed that values of storey
displacement are increases at top level from
ground. From the graph it is observed that the value
of displacements varies linearly for response
spectrum analysis. The value of top storey
displacements for Bhuj earthquake is 32.026mm
and forKoyna earthquake it is 21.528mm by time
history analysis.
F. Storey Drift :
As per clause no 7.11.1 of IS-1893 (Part-1) 2002
[7]: the storey drift in any storey due to specified
design lateral force with partial load factor of 1
shall not exceed 0.004 times the storey height.
Maximum storey drift for building= 0.004 X h, for
3.2m storey height it is 0.0128m.
Table 3: Variation of story drift for earthquake by RSM and THM
Story level
(mm)
Story drift (m)
Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM
0 0 0 0 0
2000 0.000323 0.000734 0.000486 0.001102
5200 0.001212 0.002793 0.001708 0.004189
8400 0.001526 0.003126 0.002131 0.004689
11600 0.001700 0.003054 0.002293 0.004582
14800 0.001670 0.002893 0.002339 0.004339
18000 0.001546 0.002704 0.002261 0.004056
21200 0.001517 0.002506 0.002157 0.003763
24400 0.001455 0.002305 0.002094 0.003457
27600 0.001306 0.002094 0.002036 0.003141
30800 0.001083 0.001868 0.001887 0.002802
34000 0.000924 0.001613 0.001668 0.002421
37200 0.000752 0.001322 0.001347 0.001983
40400 0.000697 0.000992 0.001044 0.001488
43600 0.000470 0.000661 0.000717 0.000992
Fig. 4 Comparison of storey Drifts for Earthquakes using RSM&THM
G. Seismic loads on Building-
The base shear force is calculated as per IS-1893(part-1) 2002 is given by
1) forKoyna (Z=0.24) –
Z= Zone factor =0.24
I=Importance factor = 1
R= Response reduction factor = 5
Sa/g = 1.06872
W = Total seismic weight of the building
The dead load on each floor = 3.5 kN/m2
The Live load on each floor = 4kN/m2
Total seismic load on the building = 88382.66 kN
Vb = (Z/2 x I/R x Sa/g) xW
=(0.24/2 x 1/5 x 1.06872)
The Base Shear = 2272.30 KN
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 50 | P a g e
2) For Bhuj (Z=0.36) -
Z= Zone factor =0.36
I=Importance factor = 1
R= Response reduction factor = 5
Sa/g = 1.06872
W = Total seismic weight of the building
The dead load on each floor = 3.5 kN/m2
The Live load on each floor = 4kN/m2
Total seismic load on the building = 88382.66 kN
Vb = (Z/2 x I/R x Sa/g) xW
=(0.36/2 x 1/5 x 1.06872)
The Base Shear = 3409.12kN
E. Pushover Analysis –
The Pushover analysis is carried out as per the
provisions in the ATC 40 and FEMA 356 using the
software SAP 2000. The analysis result gives the
actual performance of the building when subjected
to the lateral earthquake loading.
1. Hinge formation
As per the seismic requirement, the columns should
be stronger than the beams. So the hinges should be
formed in the beam first rather than in the columns.
The figure below shows the hinge formation in the
building frame.
Fig. 5.Hinge formation at performance point for PUSH X for Koyna and Bhuj
2. Capacity spectrum and the Performance
point -The performance of building in any
earthquake can be assessed by superimposing the
capacity diagram on the seismic demand diagram.
Fig. 6: Capacity spectrum of Koyna for PUSH X
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 51 | P a g e
Fig. 7: Capacity spectrum of Bhuj for PUSH X
G .Comparision Of Base Shear Result:
Table 4:Comparison of Base shear
Base shear(KN) Manual calculation Software result SAP2000
Bhuj 3409.12 3476.294
Koyna 2272.30 2317.387
VI. CONCLUSION
From the above results it is concluded that;
1]The seismic response such as base shear for Bhuj
earthquake are found to be more by 45.44% than
Koyna earthquake by using time history analysis.
2] The base shear of Koyna and Bhuj earthquake
by response spectrum method is found to be
37.01% and 41.30% higher than time history
method.
3] The top story displacement of Koyna and Bhuj
earthquake by response spectrum method is found
to be 33.15% and 34.26% higher than time history
method.
4] The values of the storey drifts for all the stories
for all the effects are found to be within the
permissible limits specified as per IS: 1893-2002
(Part I).
5] From the results it is recommended that time
history analysis should be performed as it predicts
the Structural response more accurately than the
response spectrum analysis.
6] From Table no.4 it is observed that Base shear
results of SAP2000 software are found to be more
by 1.92 % than manually calculated base shear.
7] From figure no.6 it is found that the hinges are
found in the beams rather than columns which
show the ductile behaviour of the frame.
8] It is concluded that building used for pushover
analysis is seismically safe because performance
point base shear is greater than design base shear
for both koyna and Bhuj earthquakes.
9] The demand curve intersects the capacity curve
near the elastic range; the structure has a good
resistance and high safety against collapse.
REFERENCES
[1]. Patil A. S. and Kumbhar P. D. (2013),
―Time History Analysis of Multistoried
RCC Buildings for Different Seismic
Intensities‖, International Journal of
structural and civil engineering research,
ISSN 2319 – 6009, Vol. 2, No. 3 pp. 194-
201.
[2]. Prashanth.P, Anshuman.S, Pandey.R.K,
Arpan Herbert (2012), ―Comparison of
design results of a Structure designed
using STAAD and ETABS Software‖,
International Journal of Civil and
Structural Engineering, ISSN 0976 –
4399, Volume 2, No 3.
[3]. Wakchaure M.R, Ped S. P (2012),
―Earthquake Analysis of High Rise
Building with and Without In filled
Walls‖, International Journal of
Engineering and Innovative Technology.
ISSN: 2277-3754, Vol. 2, Issue 2. Page
No. 89-94.
[4]. Mr.ParvathaneniSubash, Mr.S.Elavenil
(2012),―Time History Response Prediction
for Multi-Storey Buildings under
Earthquake Ground Motions‖, Journal of
Civil, Structural, Environmental, Water
AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com
ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52
www.ijera.com DOI: 10.9790/9622-0705024552 52 | P a g e
resources and Infrastructure Engineering
Research Vol.2 ,Issue (2) pp 16-23
[5]. BahadorBagheri, EhsanSalimiFiroozabad,
and MohammadrezaYahyaei (2012),
―Comparative Study of the Static and
Dynamic Analysis of Multi-Storey
Irregular Building‖, World Academy of
Science, Engineering and Technology.
Vol.6. pp 1847-1851.
[6]. Bureau of Indian Standards (BIS). Plane
and Reinforced Concrete Code of Practice,
IS 456-2000 (Fourth Revision), New
Delhi.
[7]. Bureau of Indian Standards (BIS). Criteria
for Earthquake Resistant Design of
Structures, IS 1893(Part I)-2002 (Fifth
Revision), New Delhi.
[8]. Shrikhande M. and Agrawal P (2006),
―Earthquake Resistant Design of
Structures‖, First Revised Edition, PHI
Learning Private Limited, New Delhi.
[9]. Md. Arman Chowdhury1, Wahid Hassan,
―Comparative study of the Dynamic
Analysis of Multi-storey Irregular building
with or without Base Isolator‖,
International Journal of Scientific
Engineering and Technology, ISSN: 2277-
1581, Volume No.2, Issue No.9, pp: 909-
912, Sept 2013.
[10]. MahammedYousuf and R.M.Shimpale
―Dynamic analysis of Reinforced concrete
buildings with plan
irregularities‖.International Journal of
Emerging technology and Advanced
Engg.ISSN 2250-2459 ISO 9001:2008
[11]. Prof.Dr.Qaiseruz, Zaman khan
―Evaluation of effect of Response
spectrum Analysis on Height of
Building‖International conference
(ICSBE-2010).
[12]. BhavinH.ZaveriJasminA.Gadhiya
―Comparative study of steel, RCC and
composite building´‖International Journal
of Innovative Resarch in science Volume
05,1Jan2016 ISSN-2319-8753
[13]. Mahesh N. Patil, Yogesh N. Sonawane,
―Seismic Analysis of Multistoried
Building‖ from International Journal of
Engineering and Innovative Technology
(IJEIT), Volume 4, Issue 9, March 2015
ISSN: 2277-3754.
[14]. Wilkinson S and HileyR (2006), ―A Non
Linear Response Time History Model for
theSeismic Analysis of High-Rise
FramedBuildings‖, Computers and
Structures, Vol. 84.
[15]. Pravin B. Waghmare, P.S.Pajgade and N.
M. Kanhe, Response spectrum analysis of
a shear frame structure by using
MATLAB, Int. Journal of Applied
Sciences and Engineering Research, Vol.
1, No. 2, 20124
[16]. Patnala V S Neelima,
RamancharlaPradeep Kumar, ―Seismic
Behaviour of RC Frame with URM Infill:
A Case Study‖, International Journal of
Education and applied research (IJEAR),
Vol. 4, Issue Spl-2, Jan - June 2014 ISSN:
2348-0033 (Online) ISSN : 2249-4944
(IJERA), Vol. 3, Issue 4, Jul-Aug 2013,
pp.176-185 ISSN: 2248-9622..
[17]. Sagar R Padol1, Rajashekhar S. Talikoti2
―Review paper on seismic responses of
multistoredrcc building with mass
irregularity review paper on seismic
responses of multistoredrcc building with
mass irregularity‖ IJRET: International
Journal of Research in Engineering and
Technology ISSN: 2319-1163 | ISSN:
2321-7308
[18]. Romy Mohan, C Prabha, ―Dynamic
Analysis of RCC Buildings with Shear
Wall‖, International Journal of
[19]. Earth Sciences and Engineering ISSN
0974-5904,
[20]. Bhakti Narayan Harne1, Prof. R. R.
Shinde, ―Seismic Performance of Multi-
Storied RC Building with Soft Storey
International Journal of Emerging
Technology and Advanced Engineering,
Volume 5, Issue 8, August 2015 ISSN 22
[21]. N.M .Nikam ,L.G.Kulkarnix ‖Pushover
analysis of building with shear wall ―
IJESC- Volume -6 Issue no.6
[22]. Mohammad Azoz, Anshul R Nikhade
―Pushover analysis of G+10 Reinforced
concrete structures for zone II and zone III
as per IS1893(2002)‖.
[23]. Jyotipatil, dr.D.KKulkarni ―Performance
based evaluation of framed reinforced
shear wall by pushover
analysis‖International journal of
engineering and technology ISSN2395-
0056
,

More Related Content

What's hot

Static Analysis of G+2 Institutional Building in Bhopal
Static Analysis of G+2 Institutional Building in BhopalStatic Analysis of G+2 Institutional Building in Bhopal
Static Analysis of G+2 Institutional Building in BhopalIJERA Editor
 
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...IRJET Journal
 
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...IRJET Journal
 
Seismic Performance and Shear Wall Location Assessment of a RC Building- Eva...
Seismic Performance and Shear Wall Location  Assessment of a RC Building- Eva...Seismic Performance and Shear Wall Location  Assessment of a RC Building- Eva...
Seismic Performance and Shear Wall Location Assessment of a RC Building- Eva...IRJET Journal
 
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...IRJET Journal
 
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...IRJET Journal
 
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...IRJET Journal
 
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...IRJET Journal
 
Seismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresSeismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresIRJET Journal
 
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...IJSRD
 
IRJET- A Study on Effect of LRB Isolators on Varying Height of Rectangula...
IRJET-  	  A Study on Effect of LRB Isolators on Varying Height of Rectangula...IRJET-  	  A Study on Effect of LRB Isolators on Varying Height of Rectangula...
IRJET- A Study on Effect of LRB Isolators on Varying Height of Rectangula...IRJET Journal
 
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...IRJET Journal
 
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...IRJET Journal
 
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...Ijripublishers Ijri
 
IRJET- A Review on Seismic Analysis of Multistory Building for Soft Ground
IRJET- A Review on Seismic Analysis of Multistory Building for Soft GroundIRJET- A Review on Seismic Analysis of Multistory Building for Soft Ground
IRJET- A Review on Seismic Analysis of Multistory Building for Soft GroundIRJET Journal
 
Linear Dynamic Analysis and Seismic Evaluation of RC Building
Linear Dynamic Analysis and Seismic Evaluation of RC BuildingLinear Dynamic Analysis and Seismic Evaluation of RC Building
Linear Dynamic Analysis and Seismic Evaluation of RC BuildingQudsia Wahab, EIT
 
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGSEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGJournal For Research
 
Variation of deflection of steel high rise structure due to p- delta effect c...
Variation of deflection of steel high rise structure due to p- delta effect c...Variation of deflection of steel high rise structure due to p- delta effect c...
Variation of deflection of steel high rise structure due to p- delta effect c...Yousuf Dinar
 

What's hot (20)

Static Analysis of G+2 Institutional Building in Bhopal
Static Analysis of G+2 Institutional Building in BhopalStatic Analysis of G+2 Institutional Building in Bhopal
Static Analysis of G+2 Institutional Building in Bhopal
 
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...
IRJET-Effect of Non-Linear Soil Types on Seismic Response of Bridge Pier Supp...
 
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...
IRJET- Review Paper on Convincement based Seismic Design of Open Ground Store...
 
Seismic Performance and Shear Wall Location Assessment of a RC Building- Eva...
Seismic Performance and Shear Wall Location  Assessment of a RC Building- Eva...Seismic Performance and Shear Wall Location  Assessment of a RC Building- Eva...
Seismic Performance and Shear Wall Location Assessment of a RC Building- Eva...
 
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...
IRJET- Seismic Analysis of Low Rise, Mid Rise and High Rise RCC Structure on ...
 
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...
Influence of Aspect Ratio & Plan Configurations on Seismic Performance of Mul...
 
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
 
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...
IRJET- The Behavior of Regular and Irregualr Reinforced Concrete Buildings Un...
 
Seismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresSeismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall Structures
 
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
 
IRJET- A Study on Effect of LRB Isolators on Varying Height of Rectangula...
IRJET-  	  A Study on Effect of LRB Isolators on Varying Height of Rectangula...IRJET-  	  A Study on Effect of LRB Isolators on Varying Height of Rectangula...
IRJET- A Study on Effect of LRB Isolators on Varying Height of Rectangula...
 
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
 
Capstone
CapstoneCapstone
Capstone
 
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
 
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...
 
IRJET- A Review on Seismic Analysis of Multistory Building for Soft Ground
IRJET- A Review on Seismic Analysis of Multistory Building for Soft GroundIRJET- A Review on Seismic Analysis of Multistory Building for Soft Ground
IRJET- A Review on Seismic Analysis of Multistory Building for Soft Ground
 
Linear Dynamic Analysis and Seismic Evaluation of RC Building
Linear Dynamic Analysis and Seismic Evaluation of RC BuildingLinear Dynamic Analysis and Seismic Evaluation of RC Building
Linear Dynamic Analysis and Seismic Evaluation of RC Building
 
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDINGSEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
SEISMIC ANALYSIS OF IRREGUAR (L-SHAPED) RCC BUILDING
 
Variation of deflection of steel high rise structure due to p- delta effect c...
Variation of deflection of steel high rise structure due to p- delta effect c...Variation of deflection of steel high rise structure due to p- delta effect c...
Variation of deflection of steel high rise structure due to p- delta effect c...
 
Iw3315041514
Iw3315041514Iw3315041514
Iw3315041514
 

Similar to Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes

IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...
IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...
IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...IRJET Journal
 
Review paper on seismic responses of multistored rcc building with mass irreg...
Review paper on seismic responses of multistored rcc building with mass irreg...Review paper on seismic responses of multistored rcc building with mass irreg...
Review paper on seismic responses of multistored rcc building with mass irreg...eSAT Journals
 
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
IRJET-  	  Study of Literature on Seismic Response of RC Irregular StructureIRJET-  	  Study of Literature on Seismic Response of RC Irregular Structure
IRJET- Study of Literature on Seismic Response of RC Irregular StructureIRJET Journal
 
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...IAEME Publication
 
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSIS
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSISDESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSIS
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSISIjripublishers Ijri
 
A Review on Comparative Analysis of Multistorey Buildings Under Various India...
A Review on Comparative Analysis of Multistorey Buildings Under Various India...A Review on Comparative Analysis of Multistorey Buildings Under Various India...
A Review on Comparative Analysis of Multistorey Buildings Under Various India...IRJET Journal
 
A Review on Earthquake Vulnerability Assessment
A Review on Earthquake Vulnerability AssessmentA Review on Earthquake Vulnerability Assessment
A Review on Earthquake Vulnerability AssessmentIRJET Journal
 
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
IRJET-  	  Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...IRJET-  	  Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...IRJET Journal
 
Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...IRJET Journal
 
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation Analytical Study of Response of Multi-Storey Building under Biaxial Excitation
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation IJERA Editor
 
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...Ijripublishers Ijri
 
Seismic Performance of RC Frame Building with Different Position of Shear Wall
Seismic Performance of RC Frame Building with Different Position of Shear WallSeismic Performance of RC Frame Building with Different Position of Shear Wall
Seismic Performance of RC Frame Building with Different Position of Shear Wallijtsrd
 
Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Yousuf Dinar
 
EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...
 EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE... EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...
EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...IAEME Publication
 
Seismic Analysis of Multi-Storey Structure Subjected To Different (1).pptx
Seismic  Analysis  of Multi-Storey Structure Subjected To Different (1).pptxSeismic  Analysis  of Multi-Storey Structure Subjected To Different (1).pptx
Seismic Analysis of Multi-Storey Structure Subjected To Different (1).pptxGoneJustin
 
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSIDynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSIIJERA Editor
 
IRJET- Comparative Study of Effect of Different Positions of Shear Wall o...
IRJET-  	  Comparative Study of Effect of Different Positions of Shear Wall o...IRJET-  	  Comparative Study of Effect of Different Positions of Shear Wall o...
IRJET- Comparative Study of Effect of Different Positions of Shear Wall o...IRJET Journal
 

Similar to Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes (20)

IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...
IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...
IRJET- Comparative Study & Seismic Anyalysis of Regular and Irregular Geometr...
 
Review paper on seismic responses of multistored rcc building with mass irreg...
Review paper on seismic responses of multistored rcc building with mass irreg...Review paper on seismic responses of multistored rcc building with mass irreg...
Review paper on seismic responses of multistored rcc building with mass irreg...
 
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
IRJET-  	  Study of Literature on Seismic Response of RC Irregular StructureIRJET-  	  Study of Literature on Seismic Response of RC Irregular Structure
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
 
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...
SEISMIC RESPONSE OF EXISTING RC BUILDING UNDER REVISED SEISMIC ZONE CLASSIFIC...
 
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSIS
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSISDESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSIS
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSIS
 
A Review on Comparative Analysis of Multistorey Buildings Under Various India...
A Review on Comparative Analysis of Multistorey Buildings Under Various India...A Review on Comparative Analysis of Multistorey Buildings Under Various India...
A Review on Comparative Analysis of Multistorey Buildings Under Various India...
 
A Review on Earthquake Vulnerability Assessment
A Review on Earthquake Vulnerability AssessmentA Review on Earthquake Vulnerability Assessment
A Review on Earthquake Vulnerability Assessment
 
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
IRJET-  	  Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...IRJET-  	  Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
 
Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...
 
149387.pdf
149387.pdf149387.pdf
149387.pdf
 
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation Analytical Study of Response of Multi-Storey Building under Biaxial Excitation
Analytical Study of Response of Multi-Storey Building under Biaxial Excitation
 
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
 
Seismic Performance of RC Frame Building with Different Position of Shear Wall
Seismic Performance of RC Frame Building with Different Position of Shear WallSeismic Performance of RC Frame Building with Different Position of Shear Wall
Seismic Performance of RC Frame Building with Different Position of Shear Wall
 
Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...Performance based analysis of rc building consisting shear wall and varying i...
Performance based analysis of rc building consisting shear wall and varying i...
 
Seismic Evaluation of G+2 Institutional Building in Bhopal
Seismic Evaluation of G+2 Institutional Building in BhopalSeismic Evaluation of G+2 Institutional Building in Bhopal
Seismic Evaluation of G+2 Institutional Building in Bhopal
 
EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...
 EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE... EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...
EVALUATION OF NONLINEAR STATIC PROCEDURES IN THE SEISMIC DESIGN OF REINFORCE...
 
Ijciet 06 08_007
Ijciet 06 08_007Ijciet 06 08_007
Ijciet 06 08_007
 
Seismic Analysis of Multi-Storey Structure Subjected To Different (1).pptx
Seismic  Analysis  of Multi-Storey Structure Subjected To Different (1).pptxSeismic  Analysis  of Multi-Storey Structure Subjected To Different (1).pptx
Seismic Analysis of Multi-Storey Structure Subjected To Different (1).pptx
 
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSIDynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
 
IRJET- Comparative Study of Effect of Different Positions of Shear Wall o...
IRJET-  	  Comparative Study of Effect of Different Positions of Shear Wall o...IRJET-  	  Comparative Study of Effect of Different Positions of Shear Wall o...
IRJET- Comparative Study of Effect of Different Positions of Shear Wall o...
 

Recently uploaded

HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidNikhilNagaraju
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 

Recently uploaded (20)

HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 

Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes

  • 1. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 45 | P a g e Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes Atul N.Kolekar1 , Y.P.Pawar2 , Dr. C. P. Pise3, D. D. Mohite2 , S. S. Kadam2 , C. M. Deshmukh2 . P.G. Student, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India1 Assistant Professor, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India2 Associate Professor and HOD, Department of Civil Engineering, SKNSCOE, Pandharpur, Maharashtra, India3 ABSTRACT The recent history of earthquakes have indicated that if the structures are not properly designed and constructed with required quality may cause great damage to structures. This fact has resulted in to ensure safety against earthquake forces of tall structures hence, there is need to determine seismic responses of such building for designing earthquake resistant structures by carrying seismic analysis of structure. In the present work dynamic analysis of G+12 RC multi-storied framed building considering for Koyna and Bhuj earthquake is carried out by response spectrum analysis and time history analysis and responses of such building are comparatively studied with the help of SAP2000 software. Two time histories (i.e. koyna and Bhuj) have been used to develop different acceptable criteria (base shear, storey displacement, storey drift). From the results it is recommended that time history analysis should be performed as it predicts the structural response more accurately than the response spectrum analysis. Pushover Analysis is also performed for the same building and from results it is found that building is seismically safe. Keywords—SAP2000, Response Spectrum Analysis, Seismic Responses, Time History Analysis,Pushover Analysis. I. I .INTRODUCTION The process of urbanization has been a common feature throughout the centuries, Globalization and Growth of high rise buildings is the need of current population, earthquakes have the potential for causing the greatest damages to those tall structures. Hence, it is important to take in to account the seismic load for the design of high-rise structure. Earthquakes occurred in recent past, particularly in the state of Gujarat (Bhuj, 2001) have indicated that if the structures are not properly designed and constructed with required quality may cause great damage to structures and also loss of life. Reinforced concrete buildings have been destructed on a very large scale in Bhuj earthquake of Jan 26th 2001, Even though these buildings are analyzed and designed as per IS code. The damages are caused by inconsistent seismic response, irregularity in mass and plan, soft storey and floating column etc. Hence it becomes necessary to determine actual seismic performance of building subjected to seismic forces. Time history analysis gives more realistic behavior of the building. It gives more accurately seismic responses than response spectrum analysis because of it includes material nonlinearity and dynamic nature of earthquake. Patil A. S. and Kumbhar P. D. [1] analyzed ten storied RC building considering different seismic intensities and seismic responses of such building are evaluated with the help of SAP2000 software. Five different time histories have been used considering seismic intensities V, VI, VII, VIII, IX and X for establishment of relationship between seismic intensities and seismic responses. From the study it is recommended that, to ensure safety against earthquake force, analysis of multistoried RC building using Time History method becomes necessary. Prashanth P. et al. [2] designed multi storey buildings with regular and irregular plan (as per IS 1893) using STAAD Pro and ETABS software separately. From the design results of beams, we may conclude that ETABS gave lesser area of required steel as compared to STAAD Pro. Form the design results of column; since the required steel for the column forces in this particular problem is less than the minimum steel limit of column (i.e., 0.8%), the amount of steel calculated by both the software is equal. Wakchaure M. R. and Ped S. P. [3] studied the effect of masonry walls on high rise building. Linear dynamic analysis on high rise building with different arrangement was carried out. Earthquake time history is applied to the models. The width of strut was calculated by using equivalent strut method. All analysis was carried out by software ETABS. Base shear, storey displacement, story drift RESEARCH ARTICLE OPEN ACCESS
  • 2. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 46 | P a g e was calculated and compared for all models. The results showed that infill walls reduce displacements, time period and increases base shear. Parvathaneni S. and Elavenil S. [4] done the three dimensional RC frames analysis for gravity loads and lateral loads and the response spectrum analysis and time history analysis carried out to evaluate seismic performance of frame. The response spectrum analysis and time-history analysis is done by using ETABS with compatible accelograms, and results obtained from analysis are verified. Nonlinear time history analysis is done for studying the inelastic behavior of the structures. Bahador et al. [5] studied Multi-storey irregular buildings with 20 stories using software packages ETABS and SAP 2000 for seismic zone V in India. The investigation of dynamic responses of building under actual earthquakes considering EL- CENTRO 1949 and CHI-CHI Taiwan 1999 were done. They highlighted the exactness and accuracy of Time History analysis in comparison with the most commonly adopted Response Spectrum Analysis and Equivalent Static Analysis. N.M.Nikam [20]considered G+15and G+20 storied building with provision of shear wall at different position and pushover analysisis carried out.They found that fundamental time period is increased due to provision of shear wall as well as global stiffness is increases. MohommadAzoz and AnshulR.Nikhade [21] studied pushover analysis on reinforced concrete structure in which G+10 building was subjected to push in X direction and push in Y direction. Analysis was done in sap2000 15.They found that slope of pushover curve is gradually changed with increase of the lateral displacement of the building. From results the concluded that the building considered for analysis not requires retrofitting. II. OBJECTIVES 1. To analyze the RCC multistory building for seismic forces. 2. To evaluate various responses such as base shear, lateral displacement, storey drift etc. of building for Koyna and Bhuj earthquakes. 3. To compare effect of Koyna and Bhuj earthquakes on performance of RCC multistory building. 4. To compare software results with current practices. 5. To investigate material non-linearity behaviour considering plastic analysis. III. METHODS OF ANALYSIS: A. Equivalent Static Analysis All design against seismic loads must consider the dynamic nature of the load. However, for simple regular structures, analysis by equivalent linear static methods is insufficient. This is permitted in most codes of practice for regular, low- to medium-rise buildings. This procedure takes into account the dynamic behavior of building in an approximate manner; it does not require dynamic analysis. The static method is based on the formulation given in IS codes thus it is easiest one and requires less computational efforts. First, the design base shear is computed for the whole building, and it is then distributed along the height of the building. The lateral forces at each floor levels thus obtained are distributed to individual’s lateral load resisting elements.[3,5] B. Response Spectrum Method Response spectrum method is the linear dynamic analysis method. In this method the peak structural response can be obtained directly during an earthquake using the earthquake responses (or design) spectrum. It represents the maximum responses of idealized SDOF systems with certain time period and modal damping, during earthquake ground motion. The maximum response curve is plotted for various damping values and against the undamped natural period, and can be represented in terms of maximum relative displacement or maximum relative velocity.[5,9,10,11,15,16] C. Time History Method Time History method is step by step analysis of the dynamic response of the structure at each time increment when its base is subjected to ground motion time history record. To perform such an analysis a representative earthquake time history is essential for a structure being evaluated. It is used to determine the seismic response of a structure under dynamic loading of considered earthquake.[1, 4, 14, 18] D. Pushover Analysis Pushover analysis is a static non-linear procedure of analysis of building where loading is goes on increasing with certain predefined pattern. The structure is pushed until a collapse mechanism is developed. With increase in magnitude of loads weak links and failure modes of building are found. The pushover analysis is used to get the relation between base shear and roof displacement. I.e. Pushover curve.[20,21,22]
  • 3. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 47 | P a g e IV. STRUCTURAL MODELING AND ANALYSIS : The G+12 RC multistory framed building considered for analysis to know the realistic behavior during earthquake with the general form of plan shown in fig 1. RC multi-storey framed building is modeled for two time histories i.e. Bhuj and Koyna. Plan dimensions in X and Y direction are 20m and 20m respectively. The buildings are consisting of columns with dimension 600mm x 600mm for all stories and beam with dimension 300mm x 700mm. the floor slabs are taken as 150mm thick. The height of all floors is 3.2m and height of plinth is 2m. soil type is Medium. Modal damping 5% is assumed with SMRF and I=1. The columns are assumed to be fixed at the base. Material concrete grade is M30 and while steel Fe415 is used. Fig. 1 Plan and Elevation of G+12 RC multistoried framed Building in SAP2000 V. RESULT AND DISCUSSION: The comparative study of storey displacement, base shear and storey drift of building in different stories by response spectrum analysis and time history analysis for Koyna&Bhujis performed here. The results obtained from analysis are given below and comparative study is carried out as follows D. Comparison of Base Shear: Table 1: comparison of story shear for earthquake by RSM and THM Story level (mm) Story shear (kN) Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM 43600 275.137 340.344 377.016 510.517 40400 611.824 759.264 819.801 1138.897 37200 893.170 1114.448 1283.648 1671.674 34000 1254.304 1441.154 1650.849 2116.733 30800 1504.689 1654.638 1910.848 2481.958 27600 1830.732 1850.156 2022.298 2775.235 24400 2138.652 2002.965 2394.417 3004.448 21200 2315.940 2118.321 2777.447 3177.482 18000 2432.479 2201.481 2968.719 3302.222 14800 2508.256 2257.701 2956.351 3386.552 11600 2366.272 2292.238 2818.154 3438.357 8400 1962.451 2310.348 2646.438 3465.523 5200 1566.039 2317.288 2508.267 3475.933 2000 1691.523 2317.387 2460.222 3476.294 0 1691.523 2317.387 2460.222 3476.294
  • 4. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 48 | P a g e Fig. 2 Comparison of Base Shear for Koyna&Bhuj Earthquake by THM&RSM By Time History method base shear are 1691.523 kN for Koynaand forBhuj 2460.222kN and by Response Spectrum Method values of base shear are2317.387kN for Koyna and 3476.294kN for Bhuj earthquake . E. Storey Displacements: Table 2: Comparison of story displacement for earthquake by RSM and THM Story level (mm) Story displacement (mm) Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM 0 0 0 0 0 2000 0.681 0.734 0.492 1.102 5200 3.077 3.527 2.451 5.291 8400 5.497 6.653 4.732 9.982 11600 7.714 9.707 7.038 14.562 14800 9.415 12.623 9.252 18.901 18000 11.589 15.304 11.291 22.957 21200 13.503 17.819 14.017 26.717 24400 15.198 20.115 17.484 30.174 27600 16.898 22.209 20.939 33.315 34000 20.063 25.691 27.404 38.538 37200 21.187 27.012 29.980 40.521 40400 21.347 28.004 31.827 42.009 43600 21.528 28.665 32.026 43.001 Fig. 3 Comparison of storey displacement for Earthquakes using RSM&THM
  • 5. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 49 | P a g e It has been observed that values of storey displacement are increases at top level from ground. From the graph it is observed that the value of displacements varies linearly for response spectrum analysis. The value of top storey displacements for Bhuj earthquake is 32.026mm and forKoyna earthquake it is 21.528mm by time history analysis. F. Storey Drift : As per clause no 7.11.1 of IS-1893 (Part-1) 2002 [7]: the storey drift in any storey due to specified design lateral force with partial load factor of 1 shall not exceed 0.004 times the storey height. Maximum storey drift for building= 0.004 X h, for 3.2m storey height it is 0.0128m. Table 3: Variation of story drift for earthquake by RSM and THM Story level (mm) Story drift (m) Koyna-THM Koyna-RSM Bhuj-THM Bhuj-RSM 0 0 0 0 0 2000 0.000323 0.000734 0.000486 0.001102 5200 0.001212 0.002793 0.001708 0.004189 8400 0.001526 0.003126 0.002131 0.004689 11600 0.001700 0.003054 0.002293 0.004582 14800 0.001670 0.002893 0.002339 0.004339 18000 0.001546 0.002704 0.002261 0.004056 21200 0.001517 0.002506 0.002157 0.003763 24400 0.001455 0.002305 0.002094 0.003457 27600 0.001306 0.002094 0.002036 0.003141 30800 0.001083 0.001868 0.001887 0.002802 34000 0.000924 0.001613 0.001668 0.002421 37200 0.000752 0.001322 0.001347 0.001983 40400 0.000697 0.000992 0.001044 0.001488 43600 0.000470 0.000661 0.000717 0.000992 Fig. 4 Comparison of storey Drifts for Earthquakes using RSM&THM G. Seismic loads on Building- The base shear force is calculated as per IS-1893(part-1) 2002 is given by 1) forKoyna (Z=0.24) – Z= Zone factor =0.24 I=Importance factor = 1 R= Response reduction factor = 5 Sa/g = 1.06872 W = Total seismic weight of the building The dead load on each floor = 3.5 kN/m2 The Live load on each floor = 4kN/m2 Total seismic load on the building = 88382.66 kN Vb = (Z/2 x I/R x Sa/g) xW =(0.24/2 x 1/5 x 1.06872) The Base Shear = 2272.30 KN
  • 6. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 50 | P a g e 2) For Bhuj (Z=0.36) - Z= Zone factor =0.36 I=Importance factor = 1 R= Response reduction factor = 5 Sa/g = 1.06872 W = Total seismic weight of the building The dead load on each floor = 3.5 kN/m2 The Live load on each floor = 4kN/m2 Total seismic load on the building = 88382.66 kN Vb = (Z/2 x I/R x Sa/g) xW =(0.36/2 x 1/5 x 1.06872) The Base Shear = 3409.12kN E. Pushover Analysis – The Pushover analysis is carried out as per the provisions in the ATC 40 and FEMA 356 using the software SAP 2000. The analysis result gives the actual performance of the building when subjected to the lateral earthquake loading. 1. Hinge formation As per the seismic requirement, the columns should be stronger than the beams. So the hinges should be formed in the beam first rather than in the columns. The figure below shows the hinge formation in the building frame. Fig. 5.Hinge formation at performance point for PUSH X for Koyna and Bhuj 2. Capacity spectrum and the Performance point -The performance of building in any earthquake can be assessed by superimposing the capacity diagram on the seismic demand diagram. Fig. 6: Capacity spectrum of Koyna for PUSH X
  • 7. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 51 | P a g e Fig. 7: Capacity spectrum of Bhuj for PUSH X G .Comparision Of Base Shear Result: Table 4:Comparison of Base shear Base shear(KN) Manual calculation Software result SAP2000 Bhuj 3409.12 3476.294 Koyna 2272.30 2317.387 VI. CONCLUSION From the above results it is concluded that; 1]The seismic response such as base shear for Bhuj earthquake are found to be more by 45.44% than Koyna earthquake by using time history analysis. 2] The base shear of Koyna and Bhuj earthquake by response spectrum method is found to be 37.01% and 41.30% higher than time history method. 3] The top story displacement of Koyna and Bhuj earthquake by response spectrum method is found to be 33.15% and 34.26% higher than time history method. 4] The values of the storey drifts for all the stories for all the effects are found to be within the permissible limits specified as per IS: 1893-2002 (Part I). 5] From the results it is recommended that time history analysis should be performed as it predicts the Structural response more accurately than the response spectrum analysis. 6] From Table no.4 it is observed that Base shear results of SAP2000 software are found to be more by 1.92 % than manually calculated base shear. 7] From figure no.6 it is found that the hinges are found in the beams rather than columns which show the ductile behaviour of the frame. 8] It is concluded that building used for pushover analysis is seismically safe because performance point base shear is greater than design base shear for both koyna and Bhuj earthquakes. 9] The demand curve intersects the capacity curve near the elastic range; the structure has a good resistance and high safety against collapse. REFERENCES [1]. Patil A. S. and Kumbhar P. D. (2013), ―Time History Analysis of Multistoried RCC Buildings for Different Seismic Intensities‖, International Journal of structural and civil engineering research, ISSN 2319 – 6009, Vol. 2, No. 3 pp. 194- 201. [2]. Prashanth.P, Anshuman.S, Pandey.R.K, Arpan Herbert (2012), ―Comparison of design results of a Structure designed using STAAD and ETABS Software‖, International Journal of Civil and Structural Engineering, ISSN 0976 – 4399, Volume 2, No 3. [3]. Wakchaure M.R, Ped S. P (2012), ―Earthquake Analysis of High Rise Building with and Without In filled Walls‖, International Journal of Engineering and Innovative Technology. ISSN: 2277-3754, Vol. 2, Issue 2. Page No. 89-94. [4]. Mr.ParvathaneniSubash, Mr.S.Elavenil (2012),―Time History Response Prediction for Multi-Storey Buildings under Earthquake Ground Motions‖, Journal of Civil, Structural, Environmental, Water
  • 8. AtulN.Kolekar .et.al. Int. Journal of Engineering Research and Application www.ijera.com ISSN : 2248-9622, Vol. 7, Issue 5, ( Part -2) May 2017, pp.45-52 www.ijera.com DOI: 10.9790/9622-0705024552 52 | P a g e resources and Infrastructure Engineering Research Vol.2 ,Issue (2) pp 16-23 [5]. BahadorBagheri, EhsanSalimiFiroozabad, and MohammadrezaYahyaei (2012), ―Comparative Study of the Static and Dynamic Analysis of Multi-Storey Irregular Building‖, World Academy of Science, Engineering and Technology. Vol.6. pp 1847-1851. [6]. Bureau of Indian Standards (BIS). Plane and Reinforced Concrete Code of Practice, IS 456-2000 (Fourth Revision), New Delhi. [7]. Bureau of Indian Standards (BIS). Criteria for Earthquake Resistant Design of Structures, IS 1893(Part I)-2002 (Fifth Revision), New Delhi. [8]. Shrikhande M. and Agrawal P (2006), ―Earthquake Resistant Design of Structures‖, First Revised Edition, PHI Learning Private Limited, New Delhi. [9]. Md. Arman Chowdhury1, Wahid Hassan, ―Comparative study of the Dynamic Analysis of Multi-storey Irregular building with or without Base Isolator‖, International Journal of Scientific Engineering and Technology, ISSN: 2277- 1581, Volume No.2, Issue No.9, pp: 909- 912, Sept 2013. [10]. MahammedYousuf and R.M.Shimpale ―Dynamic analysis of Reinforced concrete buildings with plan irregularities‖.International Journal of Emerging technology and Advanced Engg.ISSN 2250-2459 ISO 9001:2008 [11]. Prof.Dr.Qaiseruz, Zaman khan ―Evaluation of effect of Response spectrum Analysis on Height of Building‖International conference (ICSBE-2010). [12]. BhavinH.ZaveriJasminA.Gadhiya ―Comparative study of steel, RCC and composite building´‖International Journal of Innovative Resarch in science Volume 05,1Jan2016 ISSN-2319-8753 [13]. Mahesh N. Patil, Yogesh N. Sonawane, ―Seismic Analysis of Multistoried Building‖ from International Journal of Engineering and Innovative Technology (IJEIT), Volume 4, Issue 9, March 2015 ISSN: 2277-3754. [14]. Wilkinson S and HileyR (2006), ―A Non Linear Response Time History Model for theSeismic Analysis of High-Rise FramedBuildings‖, Computers and Structures, Vol. 84. [15]. Pravin B. Waghmare, P.S.Pajgade and N. M. Kanhe, Response spectrum analysis of a shear frame structure by using MATLAB, Int. Journal of Applied Sciences and Engineering Research, Vol. 1, No. 2, 20124 [16]. Patnala V S Neelima, RamancharlaPradeep Kumar, ―Seismic Behaviour of RC Frame with URM Infill: A Case Study‖, International Journal of Education and applied research (IJEAR), Vol. 4, Issue Spl-2, Jan - June 2014 ISSN: 2348-0033 (Online) ISSN : 2249-4944 (IJERA), Vol. 3, Issue 4, Jul-Aug 2013, pp.176-185 ISSN: 2248-9622.. [17]. Sagar R Padol1, Rajashekhar S. Talikoti2 ―Review paper on seismic responses of multistoredrcc building with mass irregularity review paper on seismic responses of multistoredrcc building with mass irregularity‖ IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 | ISSN: 2321-7308 [18]. Romy Mohan, C Prabha, ―Dynamic Analysis of RCC Buildings with Shear Wall‖, International Journal of [19]. Earth Sciences and Engineering ISSN 0974-5904, [20]. Bhakti Narayan Harne1, Prof. R. R. Shinde, ―Seismic Performance of Multi- Storied RC Building with Soft Storey International Journal of Emerging Technology and Advanced Engineering, Volume 5, Issue 8, August 2015 ISSN 22 [21]. N.M .Nikam ,L.G.Kulkarnix ‖Pushover analysis of building with shear wall ― IJESC- Volume -6 Issue no.6 [22]. Mohammad Azoz, Anshul R Nikhade ―Pushover analysis of G+10 Reinforced concrete structures for zone II and zone III as per IS1893(2002)‖. [23]. Jyotipatil, dr.D.KKulkarni ―Performance based evaluation of framed reinforced shear wall by pushover analysis‖International journal of engineering and technology ISSN2395- 0056 ,