No Error Items LED TROUBLE
1 I/M-SENSOR
Ice Maker Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
2 R-SENSOR
Refrigerator Compartment Sensor Error- This can be an Electric wire
cut, short-circuit, contact failure, or missing sensor. Cause is also a
temperature reading > 122°or < -58 ° F.
3
DEFROST
SENSOR OF R
ROOM
Ref. Defrost Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. Cause is also a temperature reading >
122°or < -58 ° F.
4 R-FAN ERROR
This error indicates the Refrigerator Evap Fan is not spinning at the
correct RPM or the fan feedback line is open.
Samsung 'Refrigerator' Diagnostic Code Quick Guide
5
I/M FUNCTION
ERROR
This error indicates the Ice tray has not returned to level after an ice
harvest. The error is displayed after three failed attempts.
6
COOL SELECT
ZONE SENSOR
Cool Select Zone Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
7
R-DEFROSTING
ERROR
Refrigerator Room defrost heater- wire cut, short-circuit, contact failure,
missing sensor housing, or defective temperature fuse/bi-metal. Defrost
on for over 80 minutes
8
PANTRY-DAMPER-
HEATER ERROR
Sensor system in Pantry Room errors
9
CR-SENSOR
4-Door
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
9
PANTRY-SENSOR
ERROR
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
10
DEFROST
SENSOR OF CR
ROOM 4-Door
CR Compartment Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
DEFROST CF Compartment Defrost Sensor Error- This can be a wire cut, short-
11
DEFROST
SENSOR OF CF
ROOM 4-Door
CF Compartment Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
12
CR-DEFROSTING
ERROR 4-Door
CR Compartment Defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
13
CF-DEFROSTING
ERROR 4-Door
CF Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
14
WATER HEATER
ERROR
Error is displayed when the water reservoir tank heater is open or shorted
No Error Items LED TROUBLE
15 EXT-SENSOR
Ambient Temp. Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
16 F-SENSOR
Freezer Compartment Sensor Error- This can be an wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
17 F-DEF-SENSOR
Freezer Room Defrost Sensor Error- This can be a wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
18 F-FAN ERROR
This error indicates the Freezer Evap. Fan is not spinning at the correct
RPM or the fan feedback line is open.
Samsung 'Refrigerator' Diagnostic Code Quick Guide
19 C-FAN ERROR
This error indicates the Condenser Fan is not spinning at the correct RPM
or the fan feedback line is open.
20 CF-SENSOR 4-Door
CF Room Sensor Error- This can be a wire cut, short-circuit, contact
failure, or missing sensor housing. This can also be caused by a
temperature reading > 122° or < -58 ° F.
20
FRENCH DOOR ICE
ROOM SENSOR
Ice Room Compartment Sensor Error- This can be an Electric wire cut,
short-circuit, contact failure, or missing sensor housing. Cause is also a
temperature reading > 122°or < -58 ° F.
21
F-DEFROSTING
ERROR
Freezer Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
22
CF-FAN ERROR
4-Door
This error indicates the CF Compartment Evap. Fan is not spinning at the
correct RPM or the fan feedback line is open.
23
CR-FAN ERROR
4-Door
This error indicates the CR Compartment Evap. Fan is not spinning at the
correct RPM or the fan feedback line is open.
23
FRENCH DOOR ICE
ROOM FAN ERROR
This error indicates the Ice Room Compartment Evap. Fan is not spinning
at the correct RPM or the fan feedback line is open.
25
ICE PIPE HEATER
ERROR
Error is displayedwhen the ice maker fill pipe heater is open or shorted.
26
Uart ERROR
COMMUNICATION
This error is not applicable, if the error is detected during diagnostic
testing please ignore it.
27
L↔M ERROR
COMMUNICATION
Communication error within the Main PCB
28
P↔M ERROR
COMMUNICATION
Communication between the Main PCB and Keypad
No Error Items Display LED TROUBLE
1 Fridge Sensor
Fridge
"Mid"
Fridge Room Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
2
Peripheral Temp
Sensor
Fridge
"Min"
Ambient Temp. Sensor Error- This can be a wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
3 Freezer Sensor
Freezer
"Max"
Freezer Room Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
4
Freezer Defrost
Sensor
Freezer
"Mid"
Freezer Room Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
5
Freezer Defrost
Error
Freezer
"Min"
Freezer Room defrosting heater- wire cut, short-circuit, contact failure,
missing sensor housing, or defective temperature fuse/bi-metal. Defrost
on for over 90 minutes
6
I/M Function
Error
No Ice
This error indicates the Ice tray has not returned to level after an ice
harvest. The error is displayed after three failed attempts.
7 I/M Sensor Error Cubed Ice
Ice Maker Sensor Error- This can be a wire cut, short-circuit, contact
failure, or missing sensor. This can also be caused by a temperature
Samsung 'Refrigerator' Diagnostic Code Quick Guide
Samsung Single Evaporator 'Refrigerator' Diagnostic Code Quick Guide
reading > 149° or < -58 ° F.
No Error Items Display LED TROUBLE
1 R-SENSOR
Fridge
5
Fridge Compartment Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
2
DEFROST
SENSOR, R
ROOM
Fridge
d
Fridge Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
This can also be caused by a temperature reading > 150° or < -58 ° F.
3
Peripheral Temp
Sensor
Freezer
E5
Ambient Temp. Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
4 F-SENSOR
Freezer
F5
Freezer Compartment Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
5 F-DEF-SENSOR
Freezer
d5
Freezer Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
This can also be caused by a temperature reading > 150° or < -58 ° F.
Samsung Older "RB" Series 'Refrigerator' Diagnostic Code Quick Guide
12 dS 22 th
Samsung 'Washer' Diagnostic Code Quick Guide
No
LED
Display
Code Description Corrective Action
1 nd 1
The water level fails to drop below the Reset Water Level
within 15 minutes.
Go to “ Will Not Drain” Troubleshooting Section.
2 LO 2 Door fails to unlock after 3 attempts. Go to “ Will Not Unlock” Troubleshooting
3 nF 3
When the water fill continues for more than 16 minutes or
there is no change of water level for 3 minutes
Go to “ No Water Fill” Troubleshooting Section.
4 FL 4 Door fails to lock after 3 attempts. Go to “ Will Not Lock” Troubleshooting.
5 nF1 5 The Hot/Cold water connection is not correct Correct Hot/Cold hose connections
6 LeE or LE 8
Water Level Sensor Trouble. (When the input signal from
the water level sensor is out of range, the unit will send out
beeping sounds and halt the cycle.)
Go to “No Water Fill” Troubleshooting Section.
7 OE E
A fault is detected in the water level sensor. Data (frequency)
shows the water level is at or above the overflow water level.
Drain process may also occur.
First check to see that all of water valves are not stuck.
If water valves are OK, check water level sensor
8 dc 10
Unbalance or cabinet bump is detected during final spin,
which prevents the drum from spinning over 400 rpm.
(Never exceeds 400 RPM due to unbalanced load)
Go to “Wet Clothes” Troubleshooting Section
9 - 11 EEPROM Fault. (Program settings are being reset.)
Go to “EEPROM Clear Mode” If display shows
“FAiL”, Replace Machine Control Board
10 E2 15
Jammed/Stuck Key. (When key input signals are detected
for more than 30 seconds, it is a stuck key.)
Check all of keys. If A key is sensed to be pressed, all
keys will do not respond
11 dL 18 Door is detected as open when the motor is operating.
Check for loose connections. Use “Quick Test Mode”
do Door lock/Unlock Test & Motor Test.
12 dS 22 Door is detected as open while trying to lock the doorDoor is detected as open while trying to lock e door.
Go to “Quick Test Mode” and then do DoorQ
Lock/Unlock Test
13 bE 25 Motor hall sensor signals sent without motor operation. Replace Machine Control Board
14 29
Abnormal high/low temperature or resistance (Thermal
sensor or PBA) resistance.
Go to “ Board Input Test” and check Water
Temperature. Check loose or pinched wires. Replace
PCB or thermistor.
15 E3 2E
MICOM is attempting to drive the motor but is not getting
any response signals from the hall sensor. Visual check
shows motor is not running. (Locked, Defective Hall Sensor
or Overload)
Evaluate wire harness for loose or unhooked
connections Go to “ Quick Test Mode” and test Motor
16 Sr 34
System Relay (Main Relay) Failure. (PCB does not notice
the relay operation when there should be.)
Replace PCB.
17 Hr 36 Heater Relay Failure (No Heater Relay Check Signal) Replace PCB
18 3E 3E
Over-current is detected. Motor won’t turn. (IPM detects
over-current.)
Check wire harness for loose or open connections. Use
“ Quick Test Mode” to test Motor.
19 2E 91 Voltage for motor control bus is over specified limit Check AC line voltage - Replace PCB
20 2E 92 Voltage for motor control bus is under specified limit. Check AC line voltage - Replace PCB
21 8E 8E MEMS Sensor Failure. (No MEMS Sensor Check Signal) Check MEMS PCB ,Main PCB & Wire-harness
22 7E 7E Silver Care Kit (Silver Care PCB) Failure. Check Silver Care PCB ,Main PCB & Wire-harness
23 PF -
It occurs when there is power failure during the washing.
(“PF” is not an error. It is to inform of power failure.)
-
24
SUdS
or
Sd
-
Suds is detected during the washing session. (“SUdS” is not
an error. If the washer is in suds period, “SUdS” will light up
instead of remaining time.)
Guide a user to reduce amount of detergent usage.
Display Description Trigger Action Taken
Dryer Thermistor Short
Sensed
The Thermistor resistance is
very low.
Check for: Clogged lint screen, Restricted
vent system, Thermistor resistance.
Dryer Thermistor Open
Sensed
The Thermistor resistance is
very high.
Check for: Clogged lint screen, Restricted
vent system, Thermistor resistance.
do Door Open
Running the dryer with door
open
Check for: Loose or open wire terminals in
Door Sense circuit.
FE Power source frequency
E
Invalid power source Frequency Check for: Non Utility power supply
dF Door Circuit Failure
Invalid state for more than 256
milliseconds
Check for: Loose or open wire terminals in
Door Sense circuit.
hE or HE Heater Error
Invalid heating Temp in running
the dryer
Check for: Restricted vent system,
Thermistor resistance.
bE Button Error PCB key closed for 75 sec. Check Display PCB for stuck button
od Over Dry
Invaled Dry Time Excessive Dry
Time
Inspect seensor bars
EEprom Fail
Invalid state of Eeprom
communication
Replace Main PCB
Samsung 'Dryer' Diagnostic Code Quick Guide
E Short
Samsung 'Microwave' Diagnostic Code Quick Guide
Failure Code Cause
E-11 Open
E-12 Short
E-13 T1 Max Time Error
E-14 Dry Up / No Load
Error Code Gas Sensor Error Case
(E-1X)
E-21 Open
E-22 Short
E-23 T1 Max Time Error (Preheating not completed)
E-24 Over temperature error
E-25 Abnormal temperature is sensed at Micro Cook
E-26 Temperature is not over the fixed AD in first 3 minutes
after cooking by heater starts.
Error Code Temp. Sensor Error Case
(E-2X)
E-31 Open (When value of HEX is above “FF” for 5 seconds)
E-32 Short
E-33 The initial value of HEX is under “14” for 30 seconds while
a weight sensor in operation.
E-34 The initial value of K calculated by a weight
sensor is above and under “±28” as value of HEX.
E-35 The value of A is “-” as a weight sensor calculates.
E-36 In case the door opens during sensor cooking.
Error Code Gas Sensor Error Case
(E-1X)
E-41 Open
E 42 Short-42
E-43 T1 Max Time Error
E-44 Dry Up
E-45 Cooling Error (3minutes)
E-46 Primary Open Error(3minutes)
E-47 The door opens during cooking
Error Code Easy/PH Sensor Error
Case (E4)
E-51 Open (Sense Failure)
E-53 Read/Write Error
E-54 Zero not to be set
Error Code EEPROM Error Case
(E-5X)
E-61 Open
E-62 Short
E-63 T1 Max Time Error
Error Code Humidity Sensor Error
Case (E-6X)
-SE- Key Short Error (10 seconds)
E-01 Door opens when the door should not be opened.
E-02 Cooking Time Setting Over Error (MWO)
E-03 Cooking Time Setting Over Error (Grill)
E-04 Cooking Time Setting Over Error (Convection)
E-05 Cooking Time Setting Over Error (Combination)
E-06 It fails to sense that the swing heater has stopped for 20
seconds during cooking.
E-08 In case function of MWO starts with spit inserted into
cavity inside.
E-09 The damper is not set to be positioned for 2 minutes.p p
Error Code Others (E-0X, Letter)
Samsung 'Electric Range' Diagnostic Code Quick Guide
Failure
Code
Cause Solution
E27
E28
Oven sensor opened(over 2950Ω)
Oven sensor shorted (Under 930Ω)
1. Disconnect power. Open the back cover. Disconnect sensor
harness from control Measure sensor resistance :1080Ω at
room temperature → If different value, replace oven sensor.
2. If there is not any problem with oven sensor, Please check
whether there is a damaged terminal or wire on harness.
3. Check resistance of oven sensor connector on main PCB
(Normal:2850Ω)
E-08
E-0A
Oven not heating error
Oven over heating error
1. Disconnect power. Open the back cover. Disconnect sensor
harness from control. Measure sensor resistance :1080Ω at
the room temperature → If different value, replace oven
sensor.
2. Check the broil, bake and convection heater. Check the
resistance of each.
3. Check whether DLB of sub PCB, Broil, Bake and
Convection heater relay are being activated
4. Check wiring harnesses between main PCB on sub PCB.
5. Check the resistance of oven sensor connector on main
PCB. (Normal : 2850Ω)
SE Shorted key
1. Check if cable of keypad has been inserted into connector
of main PCB.
2. Check for short between main PCB and connector or
keypad and cable.
3. If there is not a problem with connector on main PCB and
cable of keypad, replace the main PCB.
E-OE Door locking error
1. Disconnect power. Open the back cover. Check wiring
harness connections between door lock switch and motor.
2. Check resistance of door lock motor ,1750~1850Ω at the
room temperature.
3. With operating door lockout, measure voltage at door lock
motor. (Normal Voltage : AC 120V)
4. Check whether door locking switch is operating properly.
Error Type
Error
Mode
Cause Reason
Water
Supply
Error
4E
1. When the pulse of 100 or less is detected 1 minute
after the water supply starts
2. When flow meter pulse is 5 or less 5 seconds
after the water supply starts
3. No water detected 5 min after the supply starts
Water supply valve defect, Flow
Meter defect, Particles within water
supply valve, Water supply valve
terminal not connected
Main PBA defect
Water
Supply
Error
4E1
When 80 or above is detected during water
supply
Thermistor Defect, Water supply
temperature of 80 or above
Main PBA defect
Drain Error 5E
When OFF status of Low Level S/W is not detected
within3 minutes during the drain
Drain pump defect, Low Level
Sensor defect, Particles clogging
mater drain hose, Drain valve
terminal not connected
Main PBA defect
Overflow
Error
oE
When overflow detection AD data is 4.0V or below
for 3 seconds (When leakage sensor detects 4.0V or
below for 1 seconds during water supply)
Foreign particles in water supply
valve, Case Sensor part leakage
Flow Meter defect
Main PBA defect
B h i d f
Samsung 'Dishwasher' Diagnostic Code Quick Guide
Leakage
Error
LE
When leakage sensor detects 4.5V or below for 1
seconds
Base part hose connection defect
Sump and Tub assembly defect
Drain Pump assembly defect
Main PBA defect
Heater
Error
HE
When the temperature change is 4 or less within
the first 10 minutes after the heating starts
Heater defect
Heater Relay defect
Heater terminal not connected
Main Wire-Harness defect
Main PBA defect
Heater
Error
HE1
When the temperature of the Thermistor is 80 or
above for more than 3 seconds
Heater Relay defect
Thermistor defect
Main PBA defect
Temp
Sensor
Error
tE1
When 0.2V or below, or 4.5V or above is maintained
for over 3 seconds
Thermistor terminal not connected
Thermistor Defect
Main PBA defect
Low Water
Level
Error
9E
When Low Level is detected to cause Error even
after the water supply resumes after Low Level is
detected for the 1st time
Low Level Sensor defect
Low Level Sensor not connected
Main PBA defect
Button
Error
bE2
When the button is pressed continuously for over 30
seconds
Sub PBA defect
Main PBA defect
Half Load
Function
Error
PE
When micro s/w is not detected for over 30 seconds
after the Distributor motor starts
Distributor motor defect
Micro sw terminal not connected
Main PBA defect

More Related Content

What's hot

Innova 3123 GM OBD1 Code Reader User Manual
Innova 3123 GM OBD1 Code Reader User ManualInnova 3123 GM OBD1 Code Reader User Manual
Innova 3123 GM OBD1 Code Reader User ManualTim Miller
 
Furnace Guard Supervisory System (FSSS)
Furnace Guard Supervisory System (FSSS)Furnace Guard Supervisory System (FSSS)
Furnace Guard Supervisory System (FSSS)Jigyasa Singh
 
Handling of turbine side emergencies
Handling of turbine side emergenciesHandling of turbine side emergencies
Handling of turbine side emergenciesManohar Tatwawadi
 
POWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEPOWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEManohar Tatwawadi
 
steam turbine turbine interlocks for (KWU turbine)
steam turbine turbine interlocks for (KWU turbine)steam turbine turbine interlocks for (KWU turbine)
steam turbine turbine interlocks for (KWU turbine)Billa ParameswaraRao
 
Cfbc boiler drive interlock
Cfbc boiler drive interlockCfbc boiler drive interlock
Cfbc boiler drive interlockAshvani Shukla
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergenciesManohar Tatwawadi
 
Boiler flame scanner retrofitting
Boiler flame scanner retrofittingBoiler flame scanner retrofitting
Boiler flame scanner retrofittingAnimesh Dan
 
Steam turbine over speed trip systems (6)
Steam turbine over speed trip systems (6)Steam turbine over speed trip systems (6)
Steam turbine over speed trip systems (6)Prem Baboo
 
Unit lightup synchronisation &amp; shutdown
Unit lightup synchronisation &amp; shutdownUnit lightup synchronisation &amp; shutdown
Unit lightup synchronisation &amp; shutdownAshvani Shukla
 
89912310 boiler-purge-burner-management-system
89912310 boiler-purge-burner-management-system89912310 boiler-purge-burner-management-system
89912310 boiler-purge-burner-management-systemMowaten Masry
 
HP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineHP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineRAVI PAL SINGH
 
Unit shutdown procedure operation
Unit shutdown procedure operationUnit shutdown procedure operation
Unit shutdown procedure operationNitin Patel
 
Manual del-operador-scania-dc13dc13-072a
Manual del-operador-scania-dc13dc13-072aManual del-operador-scania-dc13dc13-072a
Manual del-operador-scania-dc13dc13-072aSergioGonzlez154
 

What's hot (20)

Innova 3123 GM OBD1 Code Reader User Manual
Innova 3123 GM OBD1 Code Reader User ManualInnova 3123 GM OBD1 Code Reader User Manual
Innova 3123 GM OBD1 Code Reader User Manual
 
Furnace Guard Supervisory System (FSSS)
Furnace Guard Supervisory System (FSSS)Furnace Guard Supervisory System (FSSS)
Furnace Guard Supervisory System (FSSS)
 
Handling of turbine side emergencies
Handling of turbine side emergenciesHandling of turbine side emergencies
Handling of turbine side emergencies
 
200 mw FSSS
200 mw FSSS200 mw FSSS
200 mw FSSS
 
POWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEPOWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINE
 
Unit protection scheme
Unit protection schemeUnit protection scheme
Unit protection scheme
 
boiler turbine emergency
boiler turbine emergencyboiler turbine emergency
boiler turbine emergency
 
steam turbine turbine interlocks for (KWU turbine)
steam turbine turbine interlocks for (KWU turbine)steam turbine turbine interlocks for (KWU turbine)
steam turbine turbine interlocks for (KWU turbine)
 
Cfbc boiler drive interlock
Cfbc boiler drive interlockCfbc boiler drive interlock
Cfbc boiler drive interlock
 
Turbine x curves
Turbine x curvesTurbine x curves
Turbine x curves
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergencies
 
Boiler flame scanner retrofitting
Boiler flame scanner retrofittingBoiler flame scanner retrofitting
Boiler flame scanner retrofitting
 
Steam turbine over speed trip systems (6)
Steam turbine over speed trip systems (6)Steam turbine over speed trip systems (6)
Steam turbine over speed trip systems (6)
 
Unit lightup synchronisation &amp; shutdown
Unit lightup synchronisation &amp; shutdownUnit lightup synchronisation &amp; shutdown
Unit lightup synchronisation &amp; shutdown
 
X12 constellation
X12 constellationX12 constellation
X12 constellation
 
89912310 boiler-purge-burner-management-system
89912310 boiler-purge-burner-management-system89912310 boiler-purge-burner-management-system
89912310 boiler-purge-burner-management-system
 
Flame Scanner.ppt
Flame Scanner.pptFlame Scanner.ppt
Flame Scanner.ppt
 
HP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineHP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam Turbine
 
Unit shutdown procedure operation
Unit shutdown procedure operationUnit shutdown procedure operation
Unit shutdown procedure operation
 
Manual del-operador-scania-dc13dc13-072a
Manual del-operador-scania-dc13dc13-072aManual del-operador-scania-dc13dc13-072a
Manual del-operador-scania-dc13dc13-072a
 

Similar to all-samsung-fault-codes-

Domestic Refrigeration
Domestic RefrigerationDomestic Refrigeration
Domestic Refrigerationglencampbell
 
cw5000 5200 water chiller manual
cw5000 5200 water chiller manualcw5000 5200 water chiller manual
cw5000 5200 water chiller manualxlntchillers .com
 
Service training top therm chiller 1 6 k w-eng_01.10.2014
Service training top therm chiller 1 6 k w-eng_01.10.2014Service training top therm chiller 1 6 k w-eng_01.10.2014
Service training top therm chiller 1 6 k w-eng_01.10.2014Nickna16
 
PJP1(Stage2) - Slide 6
PJP1(Stage2) - Slide 6PJP1(Stage2) - Slide 6
PJP1(Stage2) - Slide 6Tc Toh
 
Chapter 55 Computer Sensors
Chapter 55 Computer SensorsChapter 55 Computer Sensors
Chapter 55 Computer Sensorsmcfalltj
 
IRJET- The Modern Refrigerator System for Busy People
IRJET- The Modern Refrigerator System for Busy PeopleIRJET- The Modern Refrigerator System for Busy People
IRJET- The Modern Refrigerator System for Busy PeopleIRJET Journal
 
3 basic problems of chiller systems and their possible causes
3 basic problems of chiller systems and their possible causes3 basic problems of chiller systems and their possible causes
3 basic problems of chiller systems and their possible causesChiller Service
 
How to Fix Common Air Conditioner Problems
How to Fix Common Air Conditioner ProblemsHow to Fix Common Air Conditioner Problems
How to Fix Common Air Conditioner ProblemsNewsTipsTricks
 
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy Inc
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy IncMeasuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy Inc
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy IncJohn Blue
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Domotica daVinci
 
SenseTek Fireray 3000 installers handbook
SenseTek Fireray 3000 installers handbookSenseTek Fireray 3000 installers handbook
SenseTek Fireray 3000 installers handbookHans Bronkhorst
 
Codigos John Deere.pdf
Codigos John Deere.pdfCodigos John Deere.pdf
Codigos John Deere.pdfSandro Martin
 
Daikin simple self diagnosis by malfunction code p1-6-errorcode
Daikin simple self diagnosis by malfunction code  p1-6-errorcodeDaikin simple self diagnosis by malfunction code  p1-6-errorcode
Daikin simple self diagnosis by malfunction code p1-6-errorcodeCurteanuCostin
 
Duyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostatDuyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostaterdinc klima
 

Similar to all-samsung-fault-codes- (20)

Domestic Refrigeration
Domestic RefrigerationDomestic Refrigeration
Domestic Refrigeration
 
Ecoline-Troubleshooting-Guide.pdf
Ecoline-Troubleshooting-Guide.pdfEcoline-Troubleshooting-Guide.pdf
Ecoline-Troubleshooting-Guide.pdf
 
Mac 050
Mac 050Mac 050
Mac 050
 
cw5000 5200 water chiller manual
cw5000 5200 water chiller manualcw5000 5200 water chiller manual
cw5000 5200 water chiller manual
 
Service training top therm chiller 1 6 k w-eng_01.10.2014
Service training top therm chiller 1 6 k w-eng_01.10.2014Service training top therm chiller 1 6 k w-eng_01.10.2014
Service training top therm chiller 1 6 k w-eng_01.10.2014
 
MITSUBISHI ELECTRIC SPLIT-TYPE
MITSUBISHI ELECTRIC SPLIT-TYPEMITSUBISHI ELECTRIC SPLIT-TYPE
MITSUBISHI ELECTRIC SPLIT-TYPE
 
PJP1(Stage2) - Slide 6
PJP1(Stage2) - Slide 6PJP1(Stage2) - Slide 6
PJP1(Stage2) - Slide 6
 
Chapter 55 Computer Sensors
Chapter 55 Computer SensorsChapter 55 Computer Sensors
Chapter 55 Computer Sensors
 
IRJET- The Modern Refrigerator System for Busy People
IRJET- The Modern Refrigerator System for Busy PeopleIRJET- The Modern Refrigerator System for Busy People
IRJET- The Modern Refrigerator System for Busy People
 
3 basic problems of chiller systems and their possible causes
3 basic problems of chiller systems and their possible causes3 basic problems of chiller systems and their possible causes
3 basic problems of chiller systems and their possible causes
 
How to Fix Common Air Conditioner Problems
How to Fix Common Air Conditioner ProblemsHow to Fix Common Air Conditioner Problems
How to Fix Common Air Conditioner Problems
 
S&a cw 5000,5200 industrial water chiller
S&a cw 5000,5200 industrial water chillerS&a cw 5000,5200 industrial water chiller
S&a cw 5000,5200 industrial water chiller
 
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy Inc
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy IncMeasuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy Inc
Measuring And Controlling Energy Costs Mike Brumm Brumm Swine Consultancy Inc
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
 
SenseTek Fireray 3000 installers handbook
SenseTek Fireray 3000 installers handbookSenseTek Fireray 3000 installers handbook
SenseTek Fireray 3000 installers handbook
 
Termostato 24 v proporcional belimo ext-rcp-24
Termostato 24 v proporcional   belimo ext-rcp-24Termostato 24 v proporcional   belimo ext-rcp-24
Termostato 24 v proporcional belimo ext-rcp-24
 
Codigos John Deere.pdf
Codigos John Deere.pdfCodigos John Deere.pdf
Codigos John Deere.pdf
 
Daikin simple self diagnosis by malfunction code p1-6-errorcode
Daikin simple self diagnosis by malfunction code  p1-6-errorcodeDaikin simple self diagnosis by malfunction code  p1-6-errorcode
Daikin simple self diagnosis by malfunction code p1-6-errorcode
 
Trf ptc
Trf ptcTrf ptc
Trf ptc
 
Duyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostatDuyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostat
 

More from Darlin Collado

Tratamiento pancreatitis
Tratamiento pancreatitisTratamiento pancreatitis
Tratamiento pancreatitisDarlin Collado
 
  PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...
     PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...     PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...
  PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...Darlin Collado
 
Paradigmas darlin collado
Paradigmas darlin colladoParadigmas darlin collado
Paradigmas darlin colladoDarlin Collado
 
Infarto agudo del miocardio con elevacion del segmento
Infarto agudo del miocardio con elevacion del segmento Infarto agudo del miocardio con elevacion del segmento
Infarto agudo del miocardio con elevacion del segmento Darlin Collado
 
Diligitis vitae dolorum
Diligitis vitae dolorumDiligitis vitae dolorum
Diligitis vitae dolorumDarlin Collado
 
Darlin collado insuficiencia cardiaca
Darlin collado insuficiencia cardiacaDarlin collado insuficiencia cardiaca
Darlin collado insuficiencia cardiacaDarlin Collado
 
Darlin collado feocromocitoma
Darlin collado feocromocitomaDarlin collado feocromocitoma
Darlin collado feocromocitomaDarlin Collado
 
Cardiopatias congenitas
Cardiopatias congenitasCardiopatias congenitas
Cardiopatias congenitasDarlin Collado
 
Anillos esofagicos y tumores
Anillos esofagicos y tumoresAnillos esofagicos y tumores
Anillos esofagicos y tumoresDarlin Collado
 
Anatomia y fisiologigia del pulmon
Anatomia y fisiologigia del pulmonAnatomia y fisiologigia del pulmon
Anatomia y fisiologigia del pulmonDarlin Collado
 

More from Darlin Collado (20)

Tratamiento pancreatitis
Tratamiento pancreatitisTratamiento pancreatitis
Tratamiento pancreatitis
 
  PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...
     PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...     PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...
  PROYECTO PARA EVALUAR EL NIVEL DE CONOCIMIENTO ACTITUD Y PRÁCTICA DE LA ...
 
ACV
ACVACV
ACV
 
Derrame pleural
Derrame pleuralDerrame pleural
Derrame pleural
 
Paradigmas darlin collado
Paradigmas darlin colladoParadigmas darlin collado
Paradigmas darlin collado
 
preguntas nefrologia
preguntas nefrologiapreguntas nefrologia
preguntas nefrologia
 
Nutricion
NutricionNutricion
Nutricion
 
Infarto agudo del miocardio con elevacion del segmento
Infarto agudo del miocardio con elevacion del segmento Infarto agudo del miocardio con elevacion del segmento
Infarto agudo del miocardio con elevacion del segmento
 
Edema de pulmon
Edema de pulmonEdema de pulmon
Edema de pulmon
 
Diligitis vitae dolorum
Diligitis vitae dolorumDiligitis vitae dolorum
Diligitis vitae dolorum
 
Darlin collado insuficiencia cardiaca
Darlin collado insuficiencia cardiacaDarlin collado insuficiencia cardiaca
Darlin collado insuficiencia cardiaca
 
Darlin collado feocromocitoma
Darlin collado feocromocitomaDarlin collado feocromocitoma
Darlin collado feocromocitoma
 
Cardiopatias congenitas
Cardiopatias congenitasCardiopatias congenitas
Cardiopatias congenitas
 
Betalactamicos
Betalactamicos  Betalactamicos
Betalactamicos
 
Asma
AsmaAsma
Asma
 
Arritmias cardiacas
Arritmias cardiacasArritmias cardiacas
Arritmias cardiacas
 
Anillos esofagicos y tumores
Anillos esofagicos y tumoresAnillos esofagicos y tumores
Anillos esofagicos y tumores
 
Anemia
AnemiaAnemia
Anemia
 
Anatomia y fisiologigia del pulmon
Anatomia y fisiologigia del pulmonAnatomia y fisiologigia del pulmon
Anatomia y fisiologigia del pulmon
 
Ameboma
AmebomaAmeboma
Ameboma
 

Recently uploaded

Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...Call Girls in Nagpur High Profile
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLDeelipZope
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 

Recently uploaded (20)

Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCL
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 

all-samsung-fault-codes-

  • 1. No Error Items LED TROUBLE 1 I/M-SENSOR Ice Maker Sensor Error- This can be an Electric wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. 2 R-SENSOR Refrigerator Compartment Sensor Error- This can be an Electric wire cut, short-circuit, contact failure, or missing sensor. Cause is also a temperature reading > 122°or < -58 ° F. 3 DEFROST SENSOR OF R ROOM Ref. Defrost Sensor Error- This can be an Electric wire cut, short-circuit, contact failure, or missing sensor. Cause is also a temperature reading > 122°or < -58 ° F. 4 R-FAN ERROR This error indicates the Refrigerator Evap Fan is not spinning at the correct RPM or the fan feedback line is open. Samsung 'Refrigerator' Diagnostic Code Quick Guide 5 I/M FUNCTION ERROR This error indicates the Ice tray has not returned to level after an ice harvest. The error is displayed after three failed attempts. 6 COOL SELECT ZONE SENSOR Cool Select Zone Sensor Error- This can be an Electric wire cut, short- circuit, contact failure, or missing sensor. Cause is also a temperature reading > 122°or < -58 ° F. 7 R-DEFROSTING ERROR Refrigerator Room defrost heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes 8 PANTRY-DAMPER- HEATER ERROR Sensor system in Pantry Room errors 9 CR-SENSOR 4-Door CR Compartment Sensor Error- This can be an Electric wire cut, short- circuit, contact failure, or missing sensor. Cause is also a temperature reading > 122°or < -58 ° F. 9 PANTRY-SENSOR ERROR CR Compartment Sensor Error- This can be an Electric wire cut, short- circuit, contact failure, or missing sensor. Cause is also a temperature reading > 122°or < -58 ° F. 10 DEFROST SENSOR OF CR ROOM 4-Door CR Compartment Defrost Sensor Error- This can be a wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. DEFROST CF Compartment Defrost Sensor Error- This can be a wire cut, short- 11 DEFROST SENSOR OF CF ROOM 4-Door CF Compartment Defrost Sensor Error- This can be a wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. 12 CR-DEFROSTING ERROR 4-Door CR Compartment Defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes 13 CF-DEFROSTING ERROR 4-Door CF Compartment defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes 14 WATER HEATER ERROR Error is displayed when the water reservoir tank heater is open or shorted
  • 2. No Error Items LED TROUBLE 15 EXT-SENSOR Ambient Temp. Sensor Error- This can be an Electric wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. 16 F-SENSOR Freezer Compartment Sensor Error- This can be an wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. 17 F-DEF-SENSOR Freezer Room Defrost Sensor Error- This can be a wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 122° or < -58 ° F. 18 F-FAN ERROR This error indicates the Freezer Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. Samsung 'Refrigerator' Diagnostic Code Quick Guide 19 C-FAN ERROR This error indicates the Condenser Fan is not spinning at the correct RPM or the fan feedback line is open. 20 CF-SENSOR 4-Door CF Room Sensor Error- This can be a wire cut, short-circuit, contact failure, or missing sensor housing. This can also be caused by a temperature reading > 122° or < -58 ° F. 20 FRENCH DOOR ICE ROOM SENSOR Ice Room Compartment Sensor Error- This can be an Electric wire cut, short-circuit, contact failure, or missing sensor housing. Cause is also a temperature reading > 122°or < -58 ° F. 21 F-DEFROSTING ERROR Freezer Compartment defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes 22 CF-FAN ERROR 4-Door This error indicates the CF Compartment Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. 23 CR-FAN ERROR 4-Door This error indicates the CR Compartment Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. 23 FRENCH DOOR ICE ROOM FAN ERROR This error indicates the Ice Room Compartment Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. 25 ICE PIPE HEATER ERROR Error is displayedwhen the ice maker fill pipe heater is open or shorted. 26 Uart ERROR COMMUNICATION This error is not applicable, if the error is detected during diagnostic testing please ignore it. 27 L↔M ERROR COMMUNICATION Communication error within the Main PCB 28 P↔M ERROR COMMUNICATION Communication between the Main PCB and Keypad
  • 3. No Error Items Display LED TROUBLE 1 Fridge Sensor Fridge "Mid" Fridge Room Sensor Error- This can be an wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 149° or < -58 ° F. 2 Peripheral Temp Sensor Fridge "Min" Ambient Temp. Sensor Error- This can be a wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 149° or < -58 ° F. 3 Freezer Sensor Freezer "Max" Freezer Room Sensor Error- This can be an wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 149° or < -58 ° F. 4 Freezer Defrost Sensor Freezer "Mid" Freezer Room Defrost Sensor Error- This can be a wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 149° or < -58 ° F. 5 Freezer Defrost Error Freezer "Min" Freezer Room defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. Defrost on for over 90 minutes 6 I/M Function Error No Ice This error indicates the Ice tray has not returned to level after an ice harvest. The error is displayed after three failed attempts. 7 I/M Sensor Error Cubed Ice Ice Maker Sensor Error- This can be a wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature Samsung 'Refrigerator' Diagnostic Code Quick Guide Samsung Single Evaporator 'Refrigerator' Diagnostic Code Quick Guide reading > 149° or < -58 ° F. No Error Items Display LED TROUBLE 1 R-SENSOR Fridge 5 Fridge Compartment Sensor Error- This can be a wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 150° or < -58 ° F. 2 DEFROST SENSOR, R ROOM Fridge d Fridge Compartment defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. This can also be caused by a temperature reading > 150° or < -58 ° F. 3 Peripheral Temp Sensor Freezer E5 Ambient Temp. Sensor Error- This can be an wire cut, short-circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 150° or < -58 ° F. 4 F-SENSOR Freezer F5 Freezer Compartment Sensor Error- This can be a wire cut, short- circuit, contact failure, or missing sensor. This can also be caused by a temperature reading > 150° or < -58 ° F. 5 F-DEF-SENSOR Freezer d5 Freezer Compartment defrosting heater- wire cut, short-circuit, contact failure, missing sensor housing, or defective temperature fuse/bi-metal. This can also be caused by a temperature reading > 150° or < -58 ° F. Samsung Older "RB" Series 'Refrigerator' Diagnostic Code Quick Guide
  • 4. 12 dS 22 th Samsung 'Washer' Diagnostic Code Quick Guide No LED Display Code Description Corrective Action 1 nd 1 The water level fails to drop below the Reset Water Level within 15 minutes. Go to “ Will Not Drain” Troubleshooting Section. 2 LO 2 Door fails to unlock after 3 attempts. Go to “ Will Not Unlock” Troubleshooting 3 nF 3 When the water fill continues for more than 16 minutes or there is no change of water level for 3 minutes Go to “ No Water Fill” Troubleshooting Section. 4 FL 4 Door fails to lock after 3 attempts. Go to “ Will Not Lock” Troubleshooting. 5 nF1 5 The Hot/Cold water connection is not correct Correct Hot/Cold hose connections 6 LeE or LE 8 Water Level Sensor Trouble. (When the input signal from the water level sensor is out of range, the unit will send out beeping sounds and halt the cycle.) Go to “No Water Fill” Troubleshooting Section. 7 OE E A fault is detected in the water level sensor. Data (frequency) shows the water level is at or above the overflow water level. Drain process may also occur. First check to see that all of water valves are not stuck. If water valves are OK, check water level sensor 8 dc 10 Unbalance or cabinet bump is detected during final spin, which prevents the drum from spinning over 400 rpm. (Never exceeds 400 RPM due to unbalanced load) Go to “Wet Clothes” Troubleshooting Section 9 - 11 EEPROM Fault. (Program settings are being reset.) Go to “EEPROM Clear Mode” If display shows “FAiL”, Replace Machine Control Board 10 E2 15 Jammed/Stuck Key. (When key input signals are detected for more than 30 seconds, it is a stuck key.) Check all of keys. If A key is sensed to be pressed, all keys will do not respond 11 dL 18 Door is detected as open when the motor is operating. Check for loose connections. Use “Quick Test Mode” do Door lock/Unlock Test & Motor Test. 12 dS 22 Door is detected as open while trying to lock the doorDoor is detected as open while trying to lock e door. Go to “Quick Test Mode” and then do DoorQ Lock/Unlock Test 13 bE 25 Motor hall sensor signals sent without motor operation. Replace Machine Control Board 14 29 Abnormal high/low temperature or resistance (Thermal sensor or PBA) resistance. Go to “ Board Input Test” and check Water Temperature. Check loose or pinched wires. Replace PCB or thermistor. 15 E3 2E MICOM is attempting to drive the motor but is not getting any response signals from the hall sensor. Visual check shows motor is not running. (Locked, Defective Hall Sensor or Overload) Evaluate wire harness for loose or unhooked connections Go to “ Quick Test Mode” and test Motor 16 Sr 34 System Relay (Main Relay) Failure. (PCB does not notice the relay operation when there should be.) Replace PCB. 17 Hr 36 Heater Relay Failure (No Heater Relay Check Signal) Replace PCB 18 3E 3E Over-current is detected. Motor won’t turn. (IPM detects over-current.) Check wire harness for loose or open connections. Use “ Quick Test Mode” to test Motor. 19 2E 91 Voltage for motor control bus is over specified limit Check AC line voltage - Replace PCB 20 2E 92 Voltage for motor control bus is under specified limit. Check AC line voltage - Replace PCB 21 8E 8E MEMS Sensor Failure. (No MEMS Sensor Check Signal) Check MEMS PCB ,Main PCB & Wire-harness 22 7E 7E Silver Care Kit (Silver Care PCB) Failure. Check Silver Care PCB ,Main PCB & Wire-harness 23 PF - It occurs when there is power failure during the washing. (“PF” is not an error. It is to inform of power failure.) - 24 SUdS or Sd - Suds is detected during the washing session. (“SUdS” is not an error. If the washer is in suds period, “SUdS” will light up instead of remaining time.) Guide a user to reduce amount of detergent usage.
  • 5. Display Description Trigger Action Taken Dryer Thermistor Short Sensed The Thermistor resistance is very low. Check for: Clogged lint screen, Restricted vent system, Thermistor resistance. Dryer Thermistor Open Sensed The Thermistor resistance is very high. Check for: Clogged lint screen, Restricted vent system, Thermistor resistance. do Door Open Running the dryer with door open Check for: Loose or open wire terminals in Door Sense circuit. FE Power source frequency E Invalid power source Frequency Check for: Non Utility power supply dF Door Circuit Failure Invalid state for more than 256 milliseconds Check for: Loose or open wire terminals in Door Sense circuit. hE or HE Heater Error Invalid heating Temp in running the dryer Check for: Restricted vent system, Thermistor resistance. bE Button Error PCB key closed for 75 sec. Check Display PCB for stuck button od Over Dry Invaled Dry Time Excessive Dry Time Inspect seensor bars EEprom Fail Invalid state of Eeprom communication Replace Main PCB Samsung 'Dryer' Diagnostic Code Quick Guide
  • 6. E Short Samsung 'Microwave' Diagnostic Code Quick Guide Failure Code Cause E-11 Open E-12 Short E-13 T1 Max Time Error E-14 Dry Up / No Load Error Code Gas Sensor Error Case (E-1X) E-21 Open E-22 Short E-23 T1 Max Time Error (Preheating not completed) E-24 Over temperature error E-25 Abnormal temperature is sensed at Micro Cook E-26 Temperature is not over the fixed AD in first 3 minutes after cooking by heater starts. Error Code Temp. Sensor Error Case (E-2X) E-31 Open (When value of HEX is above “FF” for 5 seconds) E-32 Short E-33 The initial value of HEX is under “14” for 30 seconds while a weight sensor in operation. E-34 The initial value of K calculated by a weight sensor is above and under “±28” as value of HEX. E-35 The value of A is “-” as a weight sensor calculates. E-36 In case the door opens during sensor cooking. Error Code Gas Sensor Error Case (E-1X) E-41 Open E 42 Short-42 E-43 T1 Max Time Error E-44 Dry Up E-45 Cooling Error (3minutes) E-46 Primary Open Error(3minutes) E-47 The door opens during cooking Error Code Easy/PH Sensor Error Case (E4) E-51 Open (Sense Failure) E-53 Read/Write Error E-54 Zero not to be set Error Code EEPROM Error Case (E-5X) E-61 Open E-62 Short E-63 T1 Max Time Error Error Code Humidity Sensor Error Case (E-6X) -SE- Key Short Error (10 seconds) E-01 Door opens when the door should not be opened. E-02 Cooking Time Setting Over Error (MWO) E-03 Cooking Time Setting Over Error (Grill) E-04 Cooking Time Setting Over Error (Convection) E-05 Cooking Time Setting Over Error (Combination) E-06 It fails to sense that the swing heater has stopped for 20 seconds during cooking. E-08 In case function of MWO starts with spit inserted into cavity inside. E-09 The damper is not set to be positioned for 2 minutes.p p Error Code Others (E-0X, Letter)
  • 7. Samsung 'Electric Range' Diagnostic Code Quick Guide Failure Code Cause Solution E27 E28 Oven sensor opened(over 2950Ω) Oven sensor shorted (Under 930Ω) 1. Disconnect power. Open the back cover. Disconnect sensor harness from control Measure sensor resistance :1080Ω at room temperature → If different value, replace oven sensor. 2. If there is not any problem with oven sensor, Please check whether there is a damaged terminal or wire on harness. 3. Check resistance of oven sensor connector on main PCB (Normal:2850Ω) E-08 E-0A Oven not heating error Oven over heating error 1. Disconnect power. Open the back cover. Disconnect sensor harness from control. Measure sensor resistance :1080Ω at the room temperature → If different value, replace oven sensor. 2. Check the broil, bake and convection heater. Check the resistance of each. 3. Check whether DLB of sub PCB, Broil, Bake and Convection heater relay are being activated 4. Check wiring harnesses between main PCB on sub PCB. 5. Check the resistance of oven sensor connector on main PCB. (Normal : 2850Ω) SE Shorted key 1. Check if cable of keypad has been inserted into connector of main PCB. 2. Check for short between main PCB and connector or keypad and cable. 3. If there is not a problem with connector on main PCB and cable of keypad, replace the main PCB. E-OE Door locking error 1. Disconnect power. Open the back cover. Check wiring harness connections between door lock switch and motor. 2. Check resistance of door lock motor ,1750~1850Ω at the room temperature. 3. With operating door lockout, measure voltage at door lock motor. (Normal Voltage : AC 120V) 4. Check whether door locking switch is operating properly.
  • 8. Error Type Error Mode Cause Reason Water Supply Error 4E 1. When the pulse of 100 or less is detected 1 minute after the water supply starts 2. When flow meter pulse is 5 or less 5 seconds after the water supply starts 3. No water detected 5 min after the supply starts Water supply valve defect, Flow Meter defect, Particles within water supply valve, Water supply valve terminal not connected Main PBA defect Water Supply Error 4E1 When 80 or above is detected during water supply Thermistor Defect, Water supply temperature of 80 or above Main PBA defect Drain Error 5E When OFF status of Low Level S/W is not detected within3 minutes during the drain Drain pump defect, Low Level Sensor defect, Particles clogging mater drain hose, Drain valve terminal not connected Main PBA defect Overflow Error oE When overflow detection AD data is 4.0V or below for 3 seconds (When leakage sensor detects 4.0V or below for 1 seconds during water supply) Foreign particles in water supply valve, Case Sensor part leakage Flow Meter defect Main PBA defect B h i d f Samsung 'Dishwasher' Diagnostic Code Quick Guide Leakage Error LE When leakage sensor detects 4.5V or below for 1 seconds Base part hose connection defect Sump and Tub assembly defect Drain Pump assembly defect Main PBA defect Heater Error HE When the temperature change is 4 or less within the first 10 minutes after the heating starts Heater defect Heater Relay defect Heater terminal not connected Main Wire-Harness defect Main PBA defect Heater Error HE1 When the temperature of the Thermistor is 80 or above for more than 3 seconds Heater Relay defect Thermistor defect Main PBA defect Temp Sensor Error tE1 When 0.2V or below, or 4.5V or above is maintained for over 3 seconds Thermistor terminal not connected Thermistor Defect Main PBA defect Low Water Level Error 9E When Low Level is detected to cause Error even after the water supply resumes after Low Level is detected for the 1st time Low Level Sensor defect Low Level Sensor not connected Main PBA defect Button Error bE2 When the button is pressed continuously for over 30 seconds Sub PBA defect Main PBA defect Half Load Function Error PE When micro s/w is not detected for over 30 seconds after the Distributor motor starts Distributor motor defect Micro sw terminal not connected Main PBA defect