Vortex Gas Flowmeter for Process Measurement

Azbil MVF Series Micro Flow vortex gas flowmeters provide high sensitivity and quick response through the use of proprietary sensor technology. Temperature and pressure compensation are built in, negating the need for two additional devices.

  • Login to see the comments

  • Be the first to like this

Vortex Gas Flowmeter for Process Measurement

  1. 1. The MVF series of Micro Flow vortex gas flowmeters make use of our proprietary μF (Micro Flow) sensor, which has high sensitivity and quick response. As a result, MVF flowmeters achieve a wide measurement range of 100:1. In addition, a temperature and pressure compensation function is built in, so there is no need for a temperature sensor, pressure sensor, or compensation device, contributing to the reduction in total cost. Model No. configuration Ex.: MVF0500CUN0110000 Basic model No. MVF Gas type N S C G P B Connection U D A Power supply 1 Communi- cation 1 Output 0 Pipe size 050 080 100 150 Micro Flow vortex gas flowmeter 50 A (2B) 80 A (3B) 100 A (4B) 150 A (6B) With temperature & pressure compensation Without pressure compensation, with temperature compensation Low pressure range (0 to 0.1 Mpa), with temperature & pressure compensation Medium pressure range (0 to 0.3 Mpa), with temperature & pressure compensation Main unit material SCS13A Wafer connection (with spacer for JIS 10K flange) Wafer connection (with spacer for DIN PN10 flange) Wafer connection (with spacer for ANSI 150 flange) Air/nitrogen, argon Oxygen (degreasing must be selected)*1 Carbon dioxide gas City gas 13 A (LNG base), methane Propane Butane With 4 to 20 mA output + pulse output 24 Vdc power supply RS-485 communication Horizontal left to right flow, converter on top*2 Horizontal left to right flow, converter on bottom*2 Horizontal right to left flow, converter on top*2 Horizontal right to left flow, converter on bottom*2 Vertical below to above flow, converter on left*2 Vertical above to below flow, converter on left*2 None Degreasing of gas-contacting parts (necessary if fluid is oxygen)*1 None Mill sheet for main unit and vortex generator Product version Model 0 L 1 3 Material C DescriptionDirection 0 1 2 3 4 5 Option 1 0 1 Option 2 0 C Appended No. 0 *1. If oxygen (“S”) is selected, be sure to select “1” (Degreasing of gas-contacting parts) for Option 1. *2. Explanation of flow direction Specifications Model No. Pipe size Gas types Operating temperature range Operating pressure range, pressure sensor accuracy Rated power supply voltage Output signal (1) Integrated pulse output (1) Communication function Gas-contacting material Connection type Pipe size Protective structure Weight MVF050 MVF080 MVF100 MVF150 50 A 80 A 100 A 150 A Air, nitrogen, argon, oxygen, carbon dioxide (CO2), city gas (13 A), methane, propane, butane, and other inert gases and mixed gases outside the explosion limit range -15 to +60 °C Model No.: MVF 1C 011 00: 0.0–0.1 MPa, ±2% FS @23 °C Model No.: MVF 3C 011 00: 0.0–0.3 MPa, ±2% FS @23 °C Model No.: MVF 0C 011 00: 0.0–1.0 MPa, ±1% FS @23 °C 24 Vdc. Operating range: 24 Vdc±10%, 100 mA or less Instantaneous flow rate output: 4 to 20 mAdc (allowable load resistance 600 Ω max.), maximum current: 23.2 mA, approx. 3.5 mA downscale output during burnout Open collector output, contact rating: 10 to 30 Vdc, 20 mA or less, pulse weight: selectable from 0.1, 1, and 10 m3 /pulse RS-485 interface, 3-wire system Flow passage: SCS13A, SUS304. μF sensor: silicon, gold, etc. O-ring: type 4D (Viton). JIS 10K wafer connection 50 A (2B) 80 A (3B) 100 A (4B) 150 A (6B) IP67 (by JIS C 0920 and IEC 529 standards, watertight structure for the assumed outdoor installation) 6.3 kg 6.6 kg 9 kg 17 kg Left to right flow Flow direction: below to above Right to left flow Flow direction: above to below Converter is above Code 0 Converter is below Code 1 Converter is on the left Code 4 Converter is above Code 2 Converter is below Code 3 Converter is on the left Code 5 [Explanation of terms] % rdg: percentage of the reading. m3 /h (normal): indicates a value converted to volumetric flow per hour at 0 °C and 101.325 kPa (1 atmosphere). Specification method (1) 4 to 20 mA span After checking the measurement range for each pressure, specify the model. Maximum span specifications m3 /h (normal) (2) Pulse weight 50 A: 0.01, 0.1, 1, 10 m3 /pulse Other than 50 A: select from 0.1, 1, 10, and 100 m3 /pulse. Sample specification Model No. MVF0800CUN0112000 Range 0 to 500 m3 /h (normal) Pulse weight 1 m3 /pulse 50 A 80 A 100 A 150 A 8000 m3 /h (normal) 16000 m3 /h (normal) 24000 m3 /h (normal) 48000 m3 /h (normal) The minimum span specification is 1% of the maximum span specification. Micro Flow Vortex Gas Flowmeter MVF Series 7-15 1 DIGITAL CONTROLLERS 2 RECORDERS, INDICATORES 3 CONVERTERS 4 FLAMESAFEGUARD SYSTEM 5 ACTUATORS 6SENSORS 7 GASFLOW MEASUREMENTAND CONTROLPRODUCTS GAS FLOW MEASUREMENT AND CONTROL PRODUCTS
  2. 2. (1) Pressure range 0 to 0.1 MPa: MVF 1 MVF0501 (port size 50A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.01 7.4 ±Qmin ±4.8%RD ±3.4%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 237 0.02 7.4 ±Qmin ±4.8%RD ±3.3%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 258 0.03 7.4 ±Qmin ±4.7%RD ±3.2%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 279 0.05 7.4 ±Qmin ±4.7%RD ±3.1%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 322 0.1 7.4 ±Qmin ±4.6%RD ±3.0%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 428 MVF1001 (port size 100A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.01 13.7 ±Qmin ±4.8%RD ±3.4%RD 13.7 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 805 0.02 13.7 ±Qmin ±4.8%RD ±3.3%RD 13.7 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 878 0.03 13.7 ±Qmin ±4.7%RD ±3.2%RD 13.7 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 950 0.05 13.7 ±Qmin ±4.7%RD ±3.1%RD 13.7 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1095 0.1 14.6 ±Qmin ±4.6%RD ±3.0%RD 14.6 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1457 (2) Pressure range 0 to 0.3 MPa: MVF 3 MVF0503 (port size 50A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.1 7.4 ±Qmin ±5.4%RD ±4.1%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 428 0.15 7.4 ±Qmin ±5.1%RD ±3.7%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 535 0.2 7.4 ±Qmin ±4.9%RD ±3.5%RD 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 641 0.3 8.5 ±Qmin ±4.7%RD ±3.2%RD 8.5 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 854 MVF1003 (port size 100A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.1 14.6 ±Qmin ±5.4%RD ±5.7%RD 14.6 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1457 0.15 18.2 ±Qmin ±5.1%RD ±4.9%RD 18.2 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1819 0.2 21.8 ±Qmin ±4.9%RD ±4.4%RD 21.8 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 2180 0.3 29.0 ±Qmin ±4.7%RD ±3.8%RD 29.0 ≤ Q ≤ 48 48 < Q < 156 156 ≤ Q ≤ 2904 MVF0801 (port size 80A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.01 11.0 ±Qmin ±4.8%RD ±3.4%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 523 0.02 11.0 ±Qmin ±4.8%RD ±3.3%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 570 0.03 11.0 ±Qmin ±4.7%RD ±3.2%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 617 0.05 11.0 ±Qmin ±4.7%RD ±3.1%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 711 0.1 11.0 ±Qmin ±4.6%RD ±3.0%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 946 MVF1501 (port size 150A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.01 20.0 ±Qmin ±4.8%RD ±3.4%RD 20.0 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 1733 0.02 20.0 ±Qmin ±4.8%RD ±3.3%RD 20.0 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 1889 0.03 20.4 ±Qmin ±4.7%RD ±3.2%RD 20.4 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 2045 0.05 23.6 ±Qmin ±4.7%RD ±3.1%RD 23.6 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 2356 0.1 31.3 ±Qmin ±4.6%RD ±3.0%RD 31.3 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 3135 MVF0803 (port size 80A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.1 11.0 ±Qmin ±5.4%RD ±4.1%RD 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 946 0.15 11.8 ±Qmin ±5.1%RD ±3.7%RD 11.8 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 1181 0.2 14.2 ±Qmin ±4.9%RD ±3.5%RD 14.2 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 1416 0.3 18.9 ±Qmin ±4.7%RD ±3.2%RD 18.9 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 1886 MVF1503 (port size 150A) Operating pressure (MPa) Minimum measurable flow rate Qmin Accuracy 0.1 31.3 ±Qmin ±5.4%RD ±4.1%RD 31.3 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 3135 0.15 39.1 ±Qmin ±5.1%RD ±3.7%RD 39.1 ≤ Q ≤ 65 65 < Q < 286 286 ≤ Q ≤ 3913 0.2 46.9 ±Qmin ±4.9%RD ±3.5%RD 46.9 ≤ Q ≤ 78 78 < Q < 286 286 ≤ Q ≤ 4692 0.3 62.5 ±Qmin ±4.7%RD ±3.2%RD 62.5 ≤ Q ≤ 104 104 < Q < 286 286 ≤ Q ≤ 6249 Table for specifying overall accuracy (for air, after temperature and pressure compensation) Flow rate unit: m3 /h (normal) Accuracy differs according to operating pressure and flow rate range. Micro Flow Vortex Gas Flowmeter MVF Series 7-16 GAS FLOW MEASUREMENT AND CONTROL PRODUCTS 1 DIGITAL CONTROLLERS 2 RECORDERS, INDICATORES 3 CONVERTERS 4 FLAMESAFEGUARD SYSTEM 5 ACTUATORS 6 SENSORS 7 GASFLOW MEASUREMENTAND CONTROLPRODUCTS
  3. 3. (3) Pressure range 0 to 1.0 MPa: MVF 0 MVF0500 (port size 50A) Operating pressure (kPa) Minimum measurable flow rate Qmin Accuracy 100 7.4 ±Qmin ±6.7% rdg ±5.7% rdg 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 428 150 7.4 ±Qmin ±6.0% rdg ±4.9% rdg 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 535 200 7.4 ±Qmin ±5.6% rdg ±4.4% rdg 7.4 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 641 300 8.5 ±Qmin ±5.1% rdg ±3.8% rdg 8.5 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 854 400 10.7 ±Qmin ±4.9% rdg ±3.5% rdg 10.7 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 1067 500 12.8 ±Qmin ±4.8% rdg ±3.3% rdg 12.8 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 1280 600 14.9 ±Qmin ±4.7% rdg ±3.2% rdg 14.9 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 1493 700 17.1 ±Qmin ±4.6% rdg ±3.1% rdg 17.1 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 1706 800 19.2 ±Qmin ±4.6% rdg ±3.0% rdg 19.2 ≤ Q ≤ 32 32 < Q < 74 74 ≤ Q ≤ 1919 900 21.3 ±Qmin ±4.6% rdg ±3.0% rdg 21.3 ≤ Q ≤ 36 36 < Q < 74 74 ≤ Q ≤ 2131 980 23.0 ±Qmin ±4.6% rdg ±3.0% rdg 23.0 ≤ Q ≤ 38 38 < Q < 74 74 ≤ Q ≤ 2302 MVF1000 (port size 100A) Operating pressure (kPa) Minimum measurable flow rate Qmin Accuracy 100 14.6 ±Qmin ±6.7% rdg ±5.7% rdg 14.6 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1457 150 18.2 ±Qmin ±6.0% rdg ±4.9% rdg 18.2 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 1819 200 21.8 ±Qmin ±5.6% rdg ±4.4% rdg 21.8 ≤ Q ≤ 39 39 < Q < 156 156 ≤ Q ≤ 2180 300 29.0 ±Qmin ±5.1% rdg ±3.8% rdg 29.0 ≤ Q ≤ 48 48 < Q < 156 156 ≤ Q ≤ 2904 400 36.3 ±Qmin ±4.9% rdg ±3.5% rdg 36.3 ≤ Q ≤ 60 60 < Q < 156 156 ≤ Q ≤ 3628 500 43.5 ±Qmin ±4.8% rdg ±3.3% rdg 43.5 ≤ Q ≤ 73 73 < Q < 156 156 ≤ Q ≤ 4351 600 50.7 ±Qmin ±4.7% rdg ±3.2% rdg 50.7 ≤ Q ≤ 85 85 < Q < 156 156 ≤ Q ≤ 5075 700 58.0 ±Qmin ±4.6% rdg ±3.1% rdg 58.0 ≤ Q ≤ 97 97 < Q < 156 156 ≤ Q ≤ 5799 800 65.2 ±Qmin ±4.6% rdg ±3.0% rdg 65.2 ≤ Q ≤ 109 109 < Q < 156 156 ≤ Q ≤ 6522 900 72.5 ±Qmin ±4.6% rdg ±3.0% rdg 72.5 ≤ Q ≤ 121 121 < Q < 156 156 ≤ Q ≤ 7246 980 78.2 ±Qmin ±4.6% rdg ±3.0% rdg 78.2 ≤ Q ≤ 130 130 < Q < 156 156 ≤ Q ≤ 7825 MVF0800 (port size 80A) Operating pressure (kPa) Minimum measurable flow rate Qmin Accuracy 100 11.0 ±Qmin ±6.7% rdg ±5.7% rdg 11.0 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 946 150 11.8 ±Qmin ±6.0% rdg ±4.9% rdg 11.8 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 1181 200 14.2 ±Qmin ±5.6% rdg ±4.4% rdg 14.2 ≤ Q ≤ 31 31< Q < 110 110 ≤ Q ≤ 1416 300 18.9 ±Qmin ±5.1% rdg ±3.8% rdg 18.9 ≤ Q ≤ 31 31 < Q < 110 110 ≤ Q ≤ 1886 400 23.6 ±Qmin ±4.9% rdg ±3.5% rdg 23.6 ≤ Q ≤ 39 39 < Q < 110 110 ≤ Q ≤ 2355 500 28.3 ±Qmin ±4.8% rdg ±3.3% rdg 28.3 ≤ Q ≤ 47 47 < Q < 110 110 ≤ Q ≤ 2825 600 33.0 ±Qmin ±4.7% rdg ±3.2% rdg 33.0 ≤ Q ≤ 55 55 < Q < 110 110 ≤ Q ≤ 3295 700 37.6 ±Qmin ±4.6% rdg ±3.1% rdg 37.6 ≤ Q ≤ 63 63 < Q < 110 110 ≤ Q ≤ 3765 800 42.3 ±Qmin ±4.6% rdg ±3.0% rdg 42.3 ≤ Q ≤ 71 71 < Q < 110 110 ≤ Q ≤ 4235 900 47.0 ±Qmin ±4.6% rdg ±3.0% rdg 47.0 ≤ Q ≤ 78 78 < Q < 110 110 ≤ Q ≤ 4705 980 50.8 ±Qmin ±4.6% rdg ±3.0% rdg 50.8 ≤ Q ≤ 85 85 < Q < 110 110 ≤ Q ≤ 5081 MVF1500 (port size 150A) Operating pressure (kPa) Minimum measurable flow rate Qmin Accuracy 100 31.3 ±Qmin ±6.7% rdg ±5.7% rdg 31.3 ≤ Q ≤ 57 57 < Q < 286 286 ≤ Q ≤ 3135 150 39.1 ±Qmin ±6.0% rdg ±4.9% rdg 39.1 ≤ Q ≤ 65 65 < Q < 286 286 ≤ Q ≤ 3913 200 46.9 ±Qmin ±5.6% rdg ±4.4% rdg 46.9 ≤ Q ≤ 78 78 < Q < 286 286 ≤ Q ≤ 4692 300 62.5 ±Qmin ±5.1% rdg ±3.8% rdg 62.5 ≤ Q ≤ 104 104 < Q < 286 286 ≤ Q ≤ 6249 400 78.1 ±Qmin ±4.9% rdg ±3.5% rdg 78.1 ≤ Q ≤ 130 130 < Q < 286 286 ≤ Q ≤ 7806 500 93.6 ±Qmin ±4.8% rdg ±3.3% rdg 93.6 ≤ Q ≤ 156 156 < Q < 286 286 ≤ Q ≤ 9364 600 109.2 ±Qmin ±4.7% rdg ±3.2% rdg 109.2 ≤ Q ≤ 182 182 < Q < 286 286 ≤ Q ≤ 10921 700 124.8 ±Qmin ±4.6% rdg ±3.1% rdg 124.8 ≤ Q ≤ 208 208 < Q < 286 286 ≤ Q ≤ 12478 800 140.4 ±Qmin ±4.6% rdg ±3.0% rdg 140.4 ≤ Q ≤ 234 234 < Q < 286 286 ≤ Q ≤ 14035 900 155.9 ±Qmin ±4.6% rdg ±3.0% rdg 155.9 ≤ Q ≤ 260 260 < Q < 286 286 ≤ Q ≤ 15593 980 168.4 ±Qmin ±4.6% rdg ±3.0% rdg 168.4 ≤ Q ≤ 281 281 < Q < 286 286 ≤ Q ≤ 16838 External dimensions (Unit: mm)MVF050 MVF080 MVF100 MVF150 ADEINJAPAN WHILE C IRCUITSAREALIV E COVER M U STBEKEPTTIG H T 117 50 127 61 96 44 351 130 208 59 70 ADEINJAPAN WHILE C IRCUITSAREALIV E COVER M USTBEKEPTTIG H T 117 50 127 61 126 60 367 130 208 59 70 100 117 50 130 208 127 61 70.5 399 151 59 117 50 127 61 212 99 427 130 208 59 140 60 Micro Flow Vortex Gas Flowmeter MVF Series 7-17 1 DIGITAL CONTROLLERS 2 RECORDERS, INDICATORES 3 CONVERTERS 4 FLAMESAFEGUARD SYSTEM 5 ACTUATORS 6SENSORS 7 GASFLOW MEASUREMENTAND CONTROLPRODUCTS GAS FLOW MEASUREMENT AND CONTROL PRODUCTS

×