This paper introduces and generalizes a class of multilevel dynamic voltage restorer (DVR) for voltage sags/swells compensation of high-power sensitive loads. Such a device can improve the power quality of sensitive loads located in stiff systems. The proposed DVR is based on three-phase bridge converters series-connected by means of cascaded transformers using the concept of open-end winding (OEW). Hence, two DC links can provide either symmetrical (i.e., equal DC-link voltages) or asymmetrical (i.e., different DC-link voltages) operation of the DVR converters. Generalization for K-stages is presented as well. The proposed configuration is named as DVR-COEW (i.e., cascaded open-end winding). Such a topology permits to generate a maximized number of voltage levels per converter leg. The multilevel waveforms at the output voltages of the converter are generated by using a suitable PWM strategy associated with both: i) DC-link voltages ratio and ii) transformers turns ratio. Modularity and simple maintenance make the proposed DVRCOEW an attractive solution compared to some conventional configurations. The model and PWM control are addressed in this paper. Simulation and experimental results are presented.
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Cascaded Open-End Winding Transformer based DVR
1. ELECTRICAL PROJECTS USING MATLAB/SIMULINK
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
For Simulation Results of the project Contact Us
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
Cascaded Open-End Winding Transformer
based DVR
ABSTRACT
This paper introduces and generalizes a class of multilevel dynamic voltage restorer (DVR) for
voltage sags/swells compensation of high-power sensitive loads. Such a device can improve the
power quality of sensitive loads located in stiff systems. The proposed DVR is based on three-
phase bridge converters series-connected by means of cascaded transformers using the concept
of open-end winding (OEW). Hence, two DC links can provide either symmetrical (i.e., equal
DC-link voltages) or asymmetrical (i.e., different DC-link voltages) operation of the DVR
converters. Generalization for K-stages is presented as well. The proposed configuration is
named as DVR-COEW (i.e., cascaded open-end winding). Such a topology permits to generate a
maximized number of voltage levels per converter leg. The multilevel waveforms at the output
voltages of the converter are generated by using a suitable PWM strategy associated with both: i)
DC-link voltages ratio and ii) transformers turns ratio. Modularity and simple maintenance make
the proposed DVRCOEW an attractive solution compared to some conventional configurations.
The model and PWM control are addressed in this paper. Simulation and experimental results are
presented.
KEYWORDS:
1. Dynamic voltage restorer (DVR)
2. Open-end winding (OEW)
3. DC-link voltages
4. Pulse Width Modulation (PWM)
SOFTWARE: MATLAB/SIMULINK
2. ELECTRICAL PROJECTS USING MATLAB/SIMULINK
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
For Simulation Results of the project Contact Us
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
BLOCK DIAGRAM:
Fig. 1. Example of a DVR-based system
EXPECTED SIMULATION RESULTS:
Figure 2. Phase-voltage of the resultant converter in phase-a (vra) for conventional and proposed DVRs considering
an operation with 1-stage (i.e.,k = 1 with N1 = 1) having converters with a total of 6 legs. (a) Conventional DVR. (b)
Proposed COEW-DVR and symmetrical DC-link voltages (i.e., DC link voltage ratio 1:1). (c) Proposed COEW-
DVR and asymmetrical DC-link voltages (i.e., DC-link voltages ratio 2.:1)
3. ELECTRICAL PROJECTS USING MATLAB/SIMULINK
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
For Simulation Results of the project Contact Us
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
Fig. 3. Figure 7. Phase-voltage of the resultant converter in phase-a (vra) for conventional and proposed DVRs
considering an operation with 2-stages (i.e., k = 2) having converters with a total of 12 legs. (a) Conventional DVR
with N1 = 1 and N2 = 3. (b) Proposed COEW-DVR and asymmetrical DC-link voltages (i.e., DC-link voltage ratio
2:1) N1 = 1 and N2 = 2. (c) Proposed COEW-DVR and asymmetrical DC-link voltages (i.e., DC-link voltages ratio
4:1) N1 = 1 and N2 = 2.
CONCLUSION
This paper has presented a cascaded open-end winding (COEW) transformer based DVR. The
COEW-DVR configuration is generalized for k-stages. A comparison between the proposed and
conventional (using HB [6]) configurations (operating with 1-stage) is summarized in Table IV.
It can be seen that the proposed COEW-DVR has a better quality of output voltages when
compared to the conventional one with HB [6]. This is observed by means of WTHD of the
output resultant voltages vrj of the COEW-converter. Additionally, the lower values of WTHD at
the output voltages permits the proposed COEW-DVR to reduce its switching frequency to
match the same harmonic distortion value obtained for the conventional one. In this way,
semiconductor losses would give a fair comparison. The semiconductor losses estimation was
done by using the thermal module of PSIM, in which both configurations have operated under
the same vrj magnitude and WTHD value. The power of the three-phase load was 6 kW. The
4. ELECTRICAL PROJECTS USING MATLAB/SIMULINK
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
For Simulation Results of the project Contact Us
Gmail:asokatechnologies@gmail.com, Website: http://www.asokatechnologies.in
0-9347143789/9949240245
conditions and more details for these comparisons under 1-stage operation are found in [19].
Hence, the semiconductor losses estimation for COEW-DVR with 1-stage operation are reduced
up to 48.1% compared to the values obtained with conventional one. The losses comparison for 2
stages operation has been done as well. In that case, for the same switching frequency (i.e., fsw
=10kHz) the proposed COEW-DVR has presented a reduction of 25% compared to losses
obtained for conventional one.
REFERENCES
[1] D. Koval and M. Hughes, “Canadian national power quality survey: frequency of industrial
and commercial voltage sags,” Industry Applications, IEEE Transactions on, vol. 33, pp.
622–627, May 1997.
[2] R. Affolter and B. Connell, “Experience with a dynamic voltage restorer for a critical
manufacturing facility,” in Transmission and Distribution Conference and Exposition,
2003 IEEE PES, vol. 3, pp. 937–939 vol.3, Sept 2003.
[3] K. Lee, G. Venkataramanan, and T. M. Jahns, “Modeling effects of voltage unbalances in
industrial distribution systems with adjustablespeed drives,” IEEE Transactions on
Industry Applications, vol. 44, pp. 1322–1332, Sept 2008.
[4] C.-m. Ho and H.-H. Chung, “Implementation and performance evaluation of a fast dynamic
control scheme for capacitor-supported interline DVR,” Power Electronics, IEEE
Transactions on, vol. 25, no. 8, pp. 1975–1988, 2010.
[5] Y. W. Li, P. C. Loh, F. Blaabjerg, and D. Vilathgamuwa, “Investigation and improvement
of transient response of dvr at medium voltage level,” Industry Applications, IEEE
Transactions on, vol. 43, pp. 1309–1319, Sept 2007.