SlideShare a Scribd company logo
1 of 25
Download to read offline
www.brookvent.co.uk
BMV
Roof fans
www.brookvent.co.uk
BROOKVENT has over 30 years of experience in the ventilation industry, the design
and manufacture of high quality equipment for mechanical and window ventilation.
Based on long-term experience, we know the precise needs of our Clients and we are
able to propose customized solutions.
BROOKVENT offer includes complete ventilation systems designed for single and
multi-family houses, including:
—— roof and duct fans, as well as many other solutions, together with fixed pressure
control module CSR-B,
—— window aerators (hygrocontrolled, pressure controlled, manual and built-in-
windows aerators)
—— on-wall aerators,
—— air cycle recuperators - heat recovery ventilation,
—— ventilation grates (hygro- and pressure controlled),
BROOKVENT is the supplier of energy efficient ventilation systems.
It performs its operation to global scale - BROOKVENT provides its products to
clients from Baltic Sea countries, China, New Zealand and USA.
Implementation of energy efficient forced and window-based ventilation systems
of BROOKVENT guarantees comfort of everyday use and ensures healthy living
conditions.
www.brookvent.co.uk
BMV EC fans
BMV AC fans
BMV Roof fans
www.brookvent.co.uk
The roof fan is designed for external mounting
on the ends of ventilation ducts in residential,
commercial and industrial buildings with little air
pollution in the form of solid particles. The fan can
be coupled with CSR-B controller that will ensure a
stable operation of the ventilation in all conditions,
and precisely according to the design guidelines.
—— 3 models to choose from: 1.9, 2.2, 2.5
—— Horizontal air throw.
—— Structure made of plastic material.
BMV fans with EC motor
BMV 1.9 EC 2.2 EC 2.5 EC
Power [V/Hz] 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz
Maximum power consumption [W] 99 168 202
Maximum current consumption [A] 0.7 1.1 1.3
Operating temperature range [ºC] from -20 to 60 from -20 to 50 from -20 to 50
Weight (kg) 3.2 6.0 6.2
Protection closure class / Insulation
Class
IP44 cl.B IP44 cl.B IP44 cl.B
TECHNICAL DATA ELECTRICAL CONNECTION DIAGRAM
DESCRIPTION
FEATURES
DIMENSIONS
BMV 1.9 EC BMV 2.2 EC BMV 2.5 EC
—— Roof protecting against rainfall made of UV
resistant material in grey.
—— Steel mounting plate equipped with a
connector.
—— EC motor, equipped with terminal box for
electrical connection, for optimal operating
conditions i.e.: air flow, pressure, noise
emissions and power consumption.
—— Possible automatic adjustment using the
multi function CSR-B controller, e.g. in the
constant pressure system with a choice of
performance characteristics.
RED/OUTLET +10 V
L-BROWN
PHASE
WHITE/TACHO OUTLET
YELLOW/INLET 0-10 V
BLUE/GROUND
PE-YELLOW-GREEN
GROUND
N-BLUE
NEUTRAL
www.brookvent.co.uk
PERFORMANCE CURVES
PERFORMANCE CURVES
BMV 1.9 EC
BMV 2.2 EC
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 34 44 58 67 70 67 63 54 74
OUTLET 36 47 60 69 74 74 66 55 78
2
INLET 31 41 53 65 67 67 65 53 73
OUTLET 35 42 56 64 71 74 68 57 77
3
INLET 32 42 56 65 68 65 61 52 72
OUTLET 34 45 58 67 72 72 64 53 76
4
INLET 25 35 47 59 61 61 59 47 67
OUTLET 29 36 50 58 65 68 62 51 71
5
INLET 26 36 50 59 62 59 55 46 66
OUTLET 28 39 52 61 66 66 58 47 70
6
INLET 17 27 39 51 53 53 51 39 58
OUTLET 21 28 42 50 57 60 54 43 63
7
INLET 18 28 42 51 54 51 47 38 58
OUTLET 20 31 44 53 58 58 50 39 62
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 47 55 69 73 75 69 63 54 78
OUTLET 52 57 71 74 79 78 68 61 83
2
INLET 37 47 59 65 69 66 62 52 72
OUTLET 37 47 64 65 74 74 64 55 78
3
INLET 42 54 65 69 71 64 58 49 74
OUTLET 47 56 67 70 76 74 64 57 79
4
INLET 32 43 53 59 63 59 55 42 66
OUTLET 32 44 56 61 67 67 58 48 71
5
INLET 37 53 58 62 64 57 50 38 67
OUTLET 39 55 60 63 68 66 55 49 71
6
INLET 27 40 45 51 53 49 42 28 57
OUTLET 27 43 46 53 58 58 43 41 62
7
INLET 33 46 49 53 54 47 40 26 58
OUTLET 34 48 51 55 58 55 43 42 62
ACOUSTICS
ACOUSTICS
www.brookvent.co.uk
PERFORMANCE CURVES
ACCESSORIES
BMV 2.5 EC
8
Acoustic
silencers
Return flapRoof
bases
Electrical
accessories
ACOUSTICS
PERFORMANCE CHARACTERISTICS
Model [V] [rmp] [W] [A] [m3/h] Sound pressure level at a distance of 3m*
BMV 1.9 EC
10 3270 99 0.7 760 61
8 3130 89 0.6 730 60
6 2650 55 0.4 620 57
4 2060 29 0.2 480 51
BMV 2.2 EC
10 2900 168 1.1 1270 64
8 2490 111 0.7 1090 60
6 1940 56 0.4 850 53
4 1370 24 0.2 590 44
BMV 2.5 EC
10 2650 202 1.3 1490 63
8 2300 140 1.0 1290 59
6 1800 73 0.6 1000 53
4 1290 33 0.3 720 44
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 40 52 65 71 72 68 63 58 76
OUTLET 42 53 66 70 77 75 66 59 80
2
INLET 35 46 63 65 68 66 62 53 72
OUTLET 36 47 62 65 73 72 66 56 77
3
INLET 38 50 63 65 69 63 58 53 72
OUTLET 38 50 62 66 74 70 61 54 76
4
INLET 31 42 57 60 61 60 54 44 66
OUTLET 32 43 56 60 66 66 58 47 70
5
INLET 34 47 57 60 62 56 51 45 66
OUTLET 35 48 57 61 66 62 53 45 69
6
INLET 29 48 47 50 53 50 40 32 57
OUTLET 27 49 46 51 58 58 43 34 62
7
INLET 29 48 48 52 52 47 39 34 57
OUTLET 29 45 47 53 56 53 42 33 60
8
INLET 33 43 55 67 69 69 67 55 74
OUTLET 37 44 58 66 73 76 70 59 79
* Measured at point 8, 2, 4, 6 on the performance curve.
www.brookvent.co.uk
The roof fan is designed for external mounting
on the ends of the ventilation ducts in residential,
commercial and industrial buildings with little air
pollution in the form of solid particles. The fan can
be coupled with CSR-B controller that will ensure a
stable operation of the ventilation in all conditions
and precisely according to the design guidelines.
—— 3 models to choose from: 1.9, 2.2, 2.5
—— Horizontal air throw.
—— Structure made of plastic material.
BMV fans with AC motor
BMV 1.9 AC 2.2 AC 2.5 AC
Power [V/Hz] 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz
Maximum power consumption [W] 61 151 222
Maximum current consumption [A] 0.3 0.6 1.0
Operating temperature range [ºC] from -40 to 70 from -40 to 60 from -40 to 60
Weight (kg) 3.4 6.4 6.4
Protection closure class / Insulation
Class
IP44 cl.B IP44 cl.F IP44 cl.F
TECHNICAL DATA ELECTRICAL CONNECTION DIAGRAM
DESCRIPTION
FEATURES
DIMENSIONS
BMV 1.9 AC BMV 2.2 AC BMV 2.5 AC
—— Roof protecting against rainfall made of UV
resistant material in grey.
—— Steel mounting plate equipped with a
connector.
—— AC motor fitted with automatic thermal
protection reset.
—— Possible automatic adjustment using the
multi function CSR-B controller, e.g. in the
constant pressure system with a choice of
performance characteristics.
BROWN
RED
BLACK/NEUTRAL
BLUE/PHASE
YELLOW-GREEN
GROUND
www.brookvent.co.uk
BMV 1.9 AC
BMV 2.2 AC
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 32 45 58 59 64 60 53 41 67
OUTLET 32 45 59 60 66 65 55 43 70
2
INLET 27 38 58 56 62 63 58 44 67
OUTLET 29 40 60 59 64 68 61 46 71
3
INLET 28 41 54 55 60 56 49 37 64
OUTLET 28 41 55 56 62 61 51 39 66
4
INLET 24 35 55 53 59 60 55 41 64
OUTLET 26 37 57 56 61 65 58 43 67
5
INLET 22 35 48 49 54 50 43 31 57
OUTLET 22 35 49 50 56 55 45 33 60
6
INLET 18 29 49 47 53 54 49 35 58
OUTLET 20 31 51 50 55 59 52 37 61
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 44 53 66 70 72 65 59 52 75
OUTLET 45 55 68 72 77 74 65 58 80
2
INLET 35 44 58 66 70 66 62 53 73
OUTLET 34 45 63 67 74 74 65 57 78
3
INLET 41 50 63 67 69 62 56 49 72
OUTLET 42 52 65 69 74 71 62 55 77
4
INLET 32 41 55 63 67 63 59 50 70
OUTLET 31 42 60 64 71 71 62 54 75
5
INLET 36 45 58 62 64 57 51 44 67
OUTLET 37 47 60 64 69 66 57 50 72
6
INLET 26 35 49 57 61 57 53 44 64
OUTLET 25 36 54 58 65 65 56 48 69
PERFORMANCE CURVES
PERFORMANCE CURVES
ACOUSTICS
ACOUSTICS
1
3
4
5
6
1
3
4
5
6
www.brookvent.co.uk
BMV 2.5 AC
PERFORMANCE CURVES ACOUSTICS
Hz 63 125 250 500 1000 2000 4000 8000 LwA
1
INLET 42 53 66 70 72 67 60 53 76
OUTLET 45 55 70 73 77 74 64 56 80
2
INLET 34 46 66 68 69 68 64 55 74
OUTLET 35 46 66 69 75 74 67 57 79
3
INLET 37 48 61 65 67 62 55 48 71
OUTLET 40 50 65 68 72 69 59 51 76
4
INLET 30 42 62 64 65 64 60 51 71
OUTLET 31 42 62 65 71 70 63 53 75
5
INLET 31 42 55 59 61 56 49 42 65
OUTLET 34 44 59 62 66 63 53 45 69
6
INLET 24 36 56 58 59 58 54 45 64
OUTLET 25 36 56 59 65 64 57 47 69
ACCESSORIES
Acoustic
silencers
Return flapRoof
bases
Electrical
accessories
PERFORMANCE CHARACTERISTICS
Model [rmp] [W] [A] [m3/h]
Sound pressure level at a distance
of 3m [dB(A)]*
(ºC) (Kg)
BMV 1.9 AC 2520 61 0.3 600 53 -40 / +70 3.4
BMV 2.2 AC 2670 151 0.6 1170 60 -40 / +60 6.4
BMV 2.5 AC 2650 222 1.0 1500 61 -40 / +60 6.4
1
3
45
6
* Sound pressure level measured at a distance of 3m, in the fan mounted on a flat roof (Operation point no. 2 on the performance curve).
www.brookvent.co.uk
Electrical accessories:
CSR-B controller
BS 1.8 regulator
BR-1/010 regulator
BW regulator
LK 12A service switch
PDI/PDT roof base
PDDS I/T roof base with double-sided suction
Base plate with the PP connector
Acoustic silencers: TLE, TLS
CAR return flap
LE flexible coupling
Air filter KFO
Accessories
www.brookvent.co.uk
EXAMPLES OF INSTALLATION
1. CSR-B
2. Roof base
3. Base plate with the connector
4. Return flap
5. LE flexible coupling
6. flexible TLE or rigid TLS silencer
7. ventilation duct
1 1
1
2
2
7 7 7
4 4 4
5 5 5
3
777
666
www.brookvent.co.uk
CSR-B controller
ELECTRICAL ACCESSORIES
DESCRIPTION OF OPERATION
The CSR-B drivers are the regulators of the
constant pressure intended for cooperation with
duct and roof fans with AC and EC motors.
By smoothly adjusting fan speed, they ensure
constant vacuum before or constant pressure
behind the fan. The built-in PI system with
adjustable settings allows to adjust the dynamics
of pressure regulation.
.
The CSR-B is available in two versions:
—— CSR-B XC1
—— CSR-B UL EC
Both controllers are based on the PI regulator.
The XC1 model has a built-in transistor speed
regulator (for AC motors) and more extensive
interface (more options). Both controllers have
the option of setting a fixed fan speed and
programmable upper and lower limits for fans
settings.
FEATURES
—— The CSR-B controller allows for a smooth
control of fan speed in order to ensure
constant under-pressure or overpressure
value in the ventilation duct. It provides
a stable performance of the system,
regardless of the degree of opening of the
ventilation grates. It is adjusted to work
with fans and grates from BROOKVENT.
—— The night setting allows to reduce the
vacuum value set. It makes the system
comfortable to use in time, by reducing the
noise when intensive exchange of air is not
necessary.
—— In the XC1 version, it is possible to program
settings in day, night and weekly modes:
5+2d; 7d. In 7d mode, you can set 4 zones
(settings).
A built-in weekly timer acting as a clock
controlling the entire system. This function
allows to enter e.g. night settings.
—— The built-in LCD or OLED display (UL
EC version) with an easy-to-use control
keypad that allows you to read all the
performance parameters of the system and
quickly change settings.
—— Integrated support for MODBUS RS485
communication protocol, for remote
viewing of system performance parameters
and its change of settings via master
Building Management System (BMS). The
function is available in the XC1 model.
—— CSR-B indicates the following alarms:
The CSR-B-XC1 mode:
– serial communication block alarm,
– real time clock alarm
– pressure regulation failure alarm,
– transducer pressure alarm,
– no serial communication alarm.
The CSRB-UL EC:
– settings saving failure alarm
– transducer pressure alarm,
– RTC module error alarm.
—— The power switch on the housing allows
maintenance work with the fan (CSR-B-XC1).
TECHNICAL DATA
CSR-B consists of two fundamental function blocks:
—— speed regulator (phase or transistor control)
—— pressure measurement block
(development of control for speed control,
converter or EC fan).
Parameter Value
Power Supply 230 V AC / 50 Hz
Maximum current adjustment 2 A
Housing dimensions 200x150x75
Housing ABS plastic
Weight 920 g
Type of motor control Transistor
Pressure measuring range ±996 Pa
Operating temperature -25÷60°C
Degree of protection IP54
Mounting Wall mounting
Digital inputs Digital mode input
Digital outputs Potential-free relay output
Analogue output 0-10 V engine speed regulator control output
Control method Control keypad, built-in LCD display
CSR-B-XC1 CONTROLLER FOR FANS WITH AC AND EC MOTORS.
www.brookvent.co.uk
CSR-B-UL EC CONTROLLER FOR FANS WITH EC MOTORS.
The CSR-B-UL controller allows for smooth speed control of the fan with EC motor, in order to ensure the required vent air stream and the specified vacuum
value in the exhaust duct.
Parameter Value
Power Supply 230 V AC / 50 Hz
Housing dimensions 115x65x55
Housing ABS plastic
Weight 200g
Type of motor control 0-10V output
Pressure measuring range ±996 Pa
Operating temperature -25÷60°C
Degree of protection IP65
Mounting Wall mounting
Digital inputs Mode selection digital input
Digital outputs -
Analogue output 0-10 V fan control output type EC
Control/Regulation method Control keypad, built-in OLED graphical display
Speed regulator BS 1.8
Voltage (V)
Dimensions L x W x H (mm)
Weight (kg)
Current consumption (A)
Safety class
Maximum ambient temperature (°C)
1 ~ 230
78x78x63
0.11
1.8
IP 40
35
TECHNICAL DATA
W
R
APPLICATION
Applied in BMV AC to turn on / off and regulate
fan speed. It is possible to control several fans, if
the generally used current does not exceed the
accepted limit for current consumption in the
regulator.
DESIGN AND CONTROL
The regulator stands out for its precise control.
You can turn it on/off using the control knob.
Regulation starts from the minimum possible
voltage point (at which the fan rotates firmly)
up to the maximum point. The minimum
speed point can be set by setting the regulated
potentiometer.
The housing is made of plastic.
SECURITY
Input circuit in speed controller is protected
against overload (load) by the replaceable fuse.
The regulator is fitted with a high frequency
interference filter.
MOUNTING
The regulator is intended for wall mounting. It
can be surface or flush mounted. The necessary
accessories are supplied in the set - a mounting
box.
www.brookvent.co.uk
APPLICATION
It is intended for smooth BMV EC fan motor
speed regulation.
DESIGN AND CONTROL
Switch housing is made of plastic. You can turn it
on/off using the control knob. It can be regulated
from minimum to maximum value.
MOUNTING
The regulator is intended for wall mounting.
Standard version
is supplied with flush mount box. Surface-mount
is possible with MKN-3 box supplied on request.
BR-1/010 switch
BR-1/010
Voltage (V) 10-48 V DC
Tracking signal (V) 0-10
Maximum current consumption (mA) 5 mA
Dimensions AxBxC (mm) 78x78x63
Maximum ambient temperature (°
C) 35
Safety class IP 40
Weight (kg) 0.12
TECHNICAL DATA
MOUNTING BOXES:
Electrical connection diagram
MKN-3 for surface mounting
(Optional)
MKV-4 for flush mounting
(supplied as standard)
Marks:
W – Fan;
R – BR-1/010 Regulator
www.brookvent.co.uk
BW transformer regulator to adjust the speed
of single-phase fan motors, hot pluggable,
controlled with voltage. Mounted in industrial
ventilation or heating systems. A knob located
on the housing panel allows to set the speed at
5 levels. Equipped with an independent switch,
indicating switching with backlight. Made in the
2nd isolation class. Degree of protection IP30
or IP54. Maximum ambient temperature 40°C.
Thermal class of insulation B (130°C). Made in
accordance with EN 61558-2-13.
Range of SEC currents: 0.5 - 14 A
Range of PRI: 230 V, 50/60 Hz
SEC voltage range: 5-Level speed control
BW fan speed transformer regulator
Ur (V) / Ir (A)
Dimensions (mm)
Type
Type
BW 0.5
BW 0.5
BW 1.5
BW 1.5
BW 3.0 IP54
BW 3.0 IP54
BW 7.0
BW 7.0
BW 14.0
BW 14.0
BW 2.0/1 IP54
BW 2.0/1 IP54
BW 5.0
BW 5.0
BW 10.0
BW 10.0
1
1
2
2
3
3
4
4
5
5
Upri (B)
Weight (kg)
Current (A)
Mounting
0.5
M4
1.5
M4
3
M4
7
M6
14
M6
230
0.7
230
1.50
230
2.50
230
5.50
230
10.50
2
M4
5
M6
10
M6
230
2.30
230
4.50
230
8.50
110/0.5
70
115/1.5
96
115/2.2
96
80/6.0
145
80/8.0
147
BW 0.5
BW 0.6
–
–
230/1.5
148
230/2.0
148
230/3.0
148
230/5.0
155
230/7.0
155
230/10
255
230/14
255
170/0.5
111
135/1.5
166
135/1.5
166
105/4.3
210
105/9.5
277
230/0.5
77
155/1.5
91
155/2.8
91
135/6.6
145
135/11
155
–
–
180/1.5
78
180/3.0
78
170/7.0
100
170/12.5
113
115/1.0
96
80/4.0
145
80/6.5
147
135/2.5
166
105/6.3
210
105/7.5
277
155/1.7
91
135/4.6
145
135/8.5
155
180/2.0
78
170/5.0
100
170/10.0
113
TECHNICAL DATA
BW 1.2/1 BW 1.5/1; 2.0/1; 3.0; 5.0; 7.0; 10.0; 14.0
Regulator connection diagram:
www.brookvent.co.uk
LK 12 Aservice switch
Complete device in housing YES
Number of poles 3
The number of auxiliary switch contacts 0
The number of auxiliary NC contacts 0
The number of auxiliary NO contacts 0
Model On/off switch
Suitable for installation in switchboards NO
Suitable for front 4-hole mount NO
Suitable for intermediate fitting NO
Suitable for flat mounting YES
The type of the switching element Knob
The type of primary circuit adapter Screw connection
Degree of protection (IP) IP65
Positioned on 0 YES
Rating continuous current Iu [A] 12
TECHNICAL DATA
Universal service switch, 12 A, 3-pole. For all types
of single and three-phase motors.
DESCRIPTION
www.brookvent.co.uk
DIMENSIONS
PDI/PDT roof base
Roof base for flat roofs is made of galvanized
steel sheet. There are two types of bases
available: PDI - insulated, it has 10 mm thick
(PUR foam) insulation inside, which prevents
condensation and PDT-silencing with 50 mm
thick (mineral wool) insulation.
Flange around the base allows to mount it
securely to the roof.
DESCRIPTION
PDDS I/T roof base with double-sided suction
Base plate with the PP connector
Roof base with double-sided suction for flat roofs
is made of galvanized steel sheet. There are two
types of bases available: PDDS - insulated, with
10 mm thick (PUR foam) insulation inside, which
prevents condensation and PDDS T - silencing
with 50 mm thick (mineral wool) insulation.
Convenient mounting elements allow to anchor
the basis in the roof or attach it to the profiles.
Base plate with the PP connector (optional)
Element to close the roof base bottom fitted with
a connector of 160, 200 or 250 mm diameter.
DESCRIPTION
DESCRIPTION
300/400/500
www.brookvent.co.uk
Ød1
Nom
[mm]
L
[mm]
Silencing (dB)
for the frequency (Hz)
125 250 500 1000 2000 4000 8000
160 600 13 19 18 18 16 7 6
200 600 14 17 12 13 14 7 5
250 600 15 15 10 12 14 6 5
Ød1
Nom
[mm]
L
[mm]
Silencing (dB)
for the frequency (Hz)
125 250 500 1000 2000 4000 8000
160 1200 17 29 28 30 30 23 11
200 1200 24 30 23 26 27 16 10
250 1200 22 23 18 22 19 8 7
TLE flexible acoustic silencers
DESCRIPTION
TLE flexible acoustic silencer is made
of a perforated cable. The applied insulation is
25 mm thick and it is covered with aluminium
and polyester coating. The silencer is connected
using metal flanges which are used as nipple.
They are available in two lengths of 600 mm
and 1200 mm. Silencers can be made on
request: with seals made of EPDM, with sleeve
flanges or of different lengths.
INSULATION
The type of insulation: glass wool.
The type of insulation: From the circle - flexible.
TEMPERATURE RANGE
-20°C to +140°C
THERMAL INSULATION
OF MINERAL WOOL:
Lambda = 0.034 W/m x k in 24°C.
PRESSURE LOSSES:
According to the attached diagram.
FIRE RESISTANCE:
Silencers made of non-combustible materials.
Version - Example of marking:
TLE - threaded - this is a standard make
TLE-L - threaded with a mounted seal
made ofEPDM
TLE-F - sleeve
Example of marking
Product Code: TLE - 25 - aaa - bbb
type
Thickness of insulation*
Ø d1
L
* 50 mm insulation is available upon request
www.brookvent.co.uk
TECHNICAL DATA:
Pressure losses calculated on the extended and simple silencer.
The length of the silencer = 1.0 m
1 Pa = 0.01 mbar = approximately 0.1 mm WG
flow [m3
/h]
Pressure losses in flexible silencers TLE-25.
Silencer’spressureloss[Pa/m]
diameter100mm
flow speed 15 m/s
www.brookvent.co.uk
DIMENSIONS
TLS rigid acoustic silencers
As a standard, silencers are supplied with rubber
seal.
Inside, it is filled with mineral wool that is 50 mm
thick.
Example of marking
Product Code: TLS - 50 - aaa - bbb
type
thickness of insulation
Ø d1
L
For diameters d1 ≤ 315 mm
Cross-section for silencers: TLS made with 50
mm thick insulation and concerns the following
diameters: D-100, D-125, D-160, D-200, d-250.
These are silencers made with pressed lids.
DESCRIPTION
Description
Ød1
Nom
[mm]
D
Nom
[mm]
L
[mm]
Silencing (dB)
for the frequency (Hz) Weight
[kg]
125 250 500 1000 2000 4000 8000
TLS-50-160-300 160 250 350 3 9 20 33 35 16 18 3
TLS-50-160-500 160 250 550 6 12 23 36 38 19 21 5
TLS-50-160-600 160 250 650 7 14 24 37 39 21 22 6
TLS-50-160-900 160 250 950 10 16 26 40 42 23 25 8
TLS-50-160-1000 160 250 1050 11 17 28 41 43 24 26 8
TLS-50-160-1200 160 250 1250 10
TLS-50-200-300 200 300 350 2 7 16 31 31 15 16 4
TLS-50-200-500 200 300 550 5 10 19 34 34 18 19 6
TLS-50-200-600 200 300 650 6 11 20 35 35 19 20 7
TLS-50-200-900 200 300 950 8 13 23 38 38 22 23 10
TLS-50-200-1000 200 300 1050 9 15 24 39 39 23 24 11
TLS-50-200-1200 200 300 1250 12
TLS-50-250-500 250 355 550 4 9 18 29 27 15 16 9
TLS-50-250-600 250 355 650 5 11 19 30 28 16 18 11
TLS-50-250-900 250 355 950 8 13 22 33 31 19 20 14
TLS-50-250-1000 250 355 1050 9 14 23 33 32 20 21 12
TLS-50-250-1200 250 355 1250 11 17 25 35 34 21 23 17
TLS-50-250-1500 250 355 1550 12 18 26 37 35 23 24 20
TLS-50 - 50 mm of insulation
DIMENSIONS
Description
Pressure drop (Pa)
for flow speed (m/s)
2 4 6 8 10
TLS-50-160-300 0.24 0.96 3.84 6.00 8.64
TLS-50-160-500 0.25 0.99 3.96 6.18 8.90
TLS-50-160-600 0.25 1.02 4.07 6.36 9.16
TLS-50-160-900 0.29 1.15 4.61 7.20 10.37
TLS-50-160-1000 0.31 1.23 4.92 7.68 11.06
TLS-50-160-1200
TLS-50-200-300 0.17 0.67 2.69 4.20 6.05
TLS-50-200-500 0.17 0.69 2.76 4.32 6.22
TLS-50-200-600 0.18 0.72 2.88 4.50 6.48
TLS-50-200-900 0.22 0.86 3.46 5.40 7.78
TLS-50-200-1000 0.24 0.94 3.76 5.88 8.47
TLS-50-200-1200
TLS-50-250-500 0.18 0.74 2.96 4.62 6.65
TLS-50-250-600 0.19 0.77 3.07 4.80 6.91
TLS-50-250-900 0.23 0.91 3.65 5.70 8.21
TLS-50-250-1000 0.25 0.99 3.96 6.18 8.90
TLS-50-250-1200 0.35 1.39 5.57 8.70 12.53
TLS-50-250-1500 0.40 1.58 6.34 9.90 14.26
TLS-50 - 50 mm of insulation
DROPS IN PRESSURE
www.brookvent.co.uk
DESCRIPTION
Tight CAR return flap is mounted inside the
ventilation duct. It effectively protects against
unwanted phenomenon of vent air reverse.
APPLICATION:
It is particularly suitable for ventilation systems
in apartment buildings, on vents from cooker
hoods, as well as in other ventilation systems.
CONSTRUCTION:
Return flap is made of galvanised steel, throttle
blinds are made of aluminium. It is equipped
with an internal seal that ensures its tightness
and reduces the noise of the blinds. The flap also
has an external seal made of foam, that provides
easy installation and sealing inside the vent duct.
Type Ød (mm) L1 (mm) L2 (mm)
CAR 160 155 66 81
CAR 200 195 72 93
CAR 250 247 120 145
DIMENSIONS
CAR return flap
www.brookvent.co.uk
APPLICATION
Flexible couplings are intended to eliminate
vibrations transmitted from the fan or other
ventilation devices to the ventilation system
and to partially compensate ventilation ducts
created as a result of temperature extensions.
Applied in ventilation devices in the temperature
range from -40ºC to +80ºC.
CONSTRUCTION
Flexible couplings form 2 mounting frames
joined together with a material that isolates from
vibration.
MOUNTING
Installation of the flexible couplings into the
ventilation system is carried out using the
mounting frames. They are mounted using
galvanized bolts and clamps.
LE flexible coupling
Series Flange diameter (mm)
LE 160; 200; 250;
Dimensions (mm)
Type
LE 200
LE 250
LE 160
ØD L
130
130
130201 0.28
251 0.35
161 0.22
Weight (kg)
KFO duct filter
DESCRIPTION
KFO duct filter is applied to filter air in round
ventilation ducts. The KFO duct filter is a box
made of galvanized steel, closed from the top
with clips. The housing has mounting connectors
with seals, made of EPDM. Special design of the
KFO filter allows for easy exchange of the filter
cartridge.
In the standard version, it is delivered with EU3
class filter.
KFO duct filter can be equipped with a filter
cartridge of EU3 or EU5 class. You can order
the filter cartridge as KFO-I filter frame or
KFO-W creased filter, which has filtering matt
secured with galvanized steel wire mesh.
DIMENSIONS
DIMENSIONS
Type Qd (mm) AxA (mm) B (mm)
KFO-160 160 210 160
KFO-200 200 250 160
KFO-250 250 300 160
Example of marking
Product Code: KFO - Qd
type
diameter
www.brookvent.co.uk
All rights reserved.
This material is for information only and it is not a commercial offer. Brookvent Polska sp. z o.o. assumes no responsibility for
any errors made in the publication and reserves the right to make amendments.
Version: v 1.0 2018
www.brookvent.co.uk
Address:
Kościuszki 14-16
Oborniki Śląskie 55-120
M: hello@brookvent.co.uk
T: +44 (0)28 9061 6505
F: +44 (0)28 9061 6505
www.brookvent.co.uk
www.brookvent.co.uk
NOTES

More Related Content

What's hot

09 hov en_0703
09 hov en_070309 hov en_0703
09 hov en_0703Adit Group
 
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...Thorne & Derrick International
 
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable TerminationsThorne & Derrick International
 
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...Thorne & Derrick International
 
Hazloc Explosion-proof Heaters AEU1 - Brochure
Hazloc Explosion-proof Heaters AEU1 - BrochureHazloc Explosion-proof Heaters AEU1 - Brochure
Hazloc Explosion-proof Heaters AEU1 - BrochureThorne & Derrick UK
 
Single phase -submersible-pump-starter
Single phase -submersible-pump-starterSingle phase -submersible-pump-starter
Single phase -submersible-pump-starterSimranNarang26
 
Product Bulletin Ametek 119625-00
Product Bulletin Ametek 119625-00Product Bulletin Ametek 119625-00
Product Bulletin Ametek 119625-00Eddy Suwito AS
 
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Thorne & Derrick International
 
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 CertifiedHazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 CertifiedThorne & Derrick International
 
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...Thorne & Derrick International
 
Product Bulletin Ametek 119655-00
Product Bulletin Ametek 119655-00Product Bulletin Ametek 119655-00
Product Bulletin Ametek 119655-00Eddy Suwito AS
 
Breaker integrated transformer
Breaker integrated transformerBreaker integrated transformer
Breaker integrated transformerhcsurfa
 
Thermon MIQ Heat Tracing Cable - Spec Sheet
Thermon MIQ Heat Tracing Cable - Spec SheetThermon MIQ Heat Tracing Cable - Spec Sheet
Thermon MIQ Heat Tracing Cable - Spec SheetThorne & Derrick UK
 
Thermon HTSX Heat Tracing Cable - Spec Sheet
Thermon HTSX Heat Tracing Cable - Spec SheetThermon HTSX Heat Tracing Cable - Spec Sheet
Thermon HTSX Heat Tracing Cable - Spec SheetThorne & Derrick UK
 

What's hot (16)

09 hov en_0703
09 hov en_070309 hov en_0703
09 hov en_0703
 
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...
Marechal DS3 GRP Plugs, Inlets & Sockets 50 Amps - Marechal DS Decontactor Fo...
 
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations
3M Cold Shrink - MV Medium Voltage Cable Joints & Cable Terminations
 
Hvac valves and_actuators_catalogue
Hvac valves and_actuators_catalogueHvac valves and_actuators_catalogue
Hvac valves and_actuators_catalogue
 
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...
Marechal DS2 METAL Plugs, Inlets & Sockets 250 Amps - Marechal DS Decontactor...
 
Hazloc Explosion-proof Heaters AEU1 - Brochure
Hazloc Explosion-proof Heaters AEU1 - BrochureHazloc Explosion-proof Heaters AEU1 - Brochure
Hazloc Explosion-proof Heaters AEU1 - Brochure
 
Single phase -submersible-pump-starter
Single phase -submersible-pump-starterSingle phase -submersible-pump-starter
Single phase -submersible-pump-starter
 
Thermon BSX Self-Regulating Heating Cable
Thermon BSX Self-Regulating Heating CableThermon BSX Self-Regulating Heating Cable
Thermon BSX Self-Regulating Heating Cable
 
Product Bulletin Ametek 119625-00
Product Bulletin Ametek 119625-00Product Bulletin Ametek 119625-00
Product Bulletin Ametek 119625-00
 
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
 
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 CertifiedHazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
Hazloc AEU1 Air Heater - Hazardous Area Explosion Proof ATEX Zone 1 Certified
 
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...
Hazardous Area Lighting, Plugs & Sockets, Control Stations & Junction Boxes |...
 
Product Bulletin Ametek 119655-00
Product Bulletin Ametek 119655-00Product Bulletin Ametek 119655-00
Product Bulletin Ametek 119655-00
 
Breaker integrated transformer
Breaker integrated transformerBreaker integrated transformer
Breaker integrated transformer
 
Thermon MIQ Heat Tracing Cable - Spec Sheet
Thermon MIQ Heat Tracing Cable - Spec SheetThermon MIQ Heat Tracing Cable - Spec Sheet
Thermon MIQ Heat Tracing Cable - Spec Sheet
 
Thermon HTSX Heat Tracing Cable - Spec Sheet
Thermon HTSX Heat Tracing Cable - Spec SheetThermon HTSX Heat Tracing Cable - Spec Sheet
Thermon HTSX Heat Tracing Cable - Spec Sheet
 

Similar to Bmv roof fan

42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdfCarrier Singapore
 
SIBA Fuses DC Traction Fuses - Rail Industry Fuse Links
SIBA Fuses DC Traction Fuses - Rail Industry Fuse LinksSIBA Fuses DC Traction Fuses - Rail Industry Fuse Links
SIBA Fuses DC Traction Fuses - Rail Industry Fuse LinksThorne & Derrick International
 
1VGA671004 - UniGear ZVC Standard Product.ppt
1VGA671004 - UniGear ZVC Standard Product.ppt1VGA671004 - UniGear ZVC Standard Product.ppt
1VGA671004 - UniGear ZVC Standard Product.pptNafir Anas
 
PDXE_PX3_SS6 8-22-14
PDXE_PX3_SS6 8-22-14PDXE_PX3_SS6 8-22-14
PDXE_PX3_SS6 8-22-14Zakir Hakim
 
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...AKBAR TRADING
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Dien Ha The
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgDien Ha The
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiThuan Kieu
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgDien Ha The
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Thuan Kieu
 
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...Thorne & Derrick International
 
Original High Current NPN Transistor BC639 639 TO-92 New ON Semiconductor
Original High Current NPN Transistor BC639 639 TO-92 New ON SemiconductorOriginal High Current NPN Transistor BC639 639 TO-92 New ON Semiconductor
Original High Current NPN Transistor BC639 639 TO-92 New ON SemiconductorAUTHELECTRONIC
 
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
 
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...Thorne & Derrick International
 
Catalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.comCatalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.comBeeteco
 
Rosenberg's OEM Fans for transformer cooling.
Rosenberg's OEM Fans for transformer cooling.Rosenberg's OEM Fans for transformer cooling.
Rosenberg's OEM Fans for transformer cooling.Rosenberg Canada
 

Similar to Bmv roof fan (20)

42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf
 
SIBA Fuses DC Traction Fuses - Rail Industry Fuse Links
SIBA Fuses DC Traction Fuses - Rail Industry Fuse LinksSIBA Fuses DC Traction Fuses - Rail Industry Fuse Links
SIBA Fuses DC Traction Fuses - Rail Industry Fuse Links
 
1VGA671004 - UniGear ZVC Standard Product.ppt
1VGA671004 - UniGear ZVC Standard Product.ppt1VGA671004 - UniGear ZVC Standard Product.ppt
1VGA671004 - UniGear ZVC Standard Product.ppt
 
PDXE_PX3_SS6 8-22-14
PDXE_PX3_SS6 8-22-14PDXE_PX3_SS6 8-22-14
PDXE_PX3_SS6 8-22-14
 
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
 
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...
SCHNEIDER - STOCK - SAUDI ARABIA- AKBAR TRADINGI c60n circuit_breakers_schnei...
 
Training Adobe
Training AdobeTraining Adobe
Training Adobe
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.orgFuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
Fuji thiet bi dien-cataloguemccbfuji-160413042900 dienhathe.org
 
Fuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fujiFuji thiet bi dien-catalogue-mccb-fuji
Fuji thiet bi dien-catalogue-mccb-fuji
 
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.orgFuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
Fuji thiet bi dien-catalogue-mccb-fuji dienhathe.org
 
Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900Fuji thiet bi dien-cataloguemccbfuji-160413042900
Fuji thiet bi dien-cataloguemccbfuji-160413042900
 
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...
ABB POLIM-D..PI-2/-3 (Indoor) High Voltage Surge Arresters AC 4-42kV - AC Sur...
 
Original High Current NPN Transistor BC639 639 TO-92 New ON Semiconductor
Original High Current NPN Transistor BC639 639 TO-92 New ON SemiconductorOriginal High Current NPN Transistor BC639 639 TO-92 New ON Semiconductor
Original High Current NPN Transistor BC639 639 TO-92 New ON Semiconductor
 
Craig & Derricott Switch Disconnectors Catalogue
Craig & Derricott Switch Disconnectors CatalogueCraig & Derricott Switch Disconnectors Catalogue
Craig & Derricott Switch Disconnectors Catalogue
 
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
Catalog MCCB dòng BW0 Fuji Electric mới nhất 2019
 
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...
A-Belco Reyrolle Easigo Range - Industrial Plugs, Sockets, Connectors & Combi...
 
Catalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.comCatalogue MCCB Fuji - Beeteco.com
Catalogue MCCB Fuji - Beeteco.com
 
Catalog mcb fuji electric
Catalog mcb fuji electricCatalog mcb fuji electric
Catalog mcb fuji electric
 
Rosenberg's OEM Fans for transformer cooling.
Rosenberg's OEM Fans for transformer cooling.Rosenberg's OEM Fans for transformer cooling.
Rosenberg's OEM Fans for transformer cooling.
 

Recently uploaded

Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
Electromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxElectromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxNANDHAKUMARA10
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...ronahami
 
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...HenryBriggs2
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdfKamal Acharya
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwaitjaanualu31
 
Path loss model, OKUMURA Model, Hata Model
Path loss model, OKUMURA Model, Hata ModelPath loss model, OKUMURA Model, Hata Model
Path loss model, OKUMURA Model, Hata ModelDrAjayKumarYadav4
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayEpec Engineered Technologies
 
Introduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfIntroduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfsumitt6_25730773
 
Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementDr. Deepak Mudgal
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdfKamal Acharya
 
8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessorAshwiniTodkar4
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsvanyagupta248
 
Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)ChandrakantDivate1
 
Worksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxWorksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxMustafa Ahmed
 
Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...ppkakm
 
Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)Ramkumar k
 
Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257subhasishdas79
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdfKamal Acharya
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...Amil baba
 

Recently uploaded (20)

Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Electromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxElectromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptx
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
 
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
Path loss model, OKUMURA Model, Hata Model
Path loss model, OKUMURA Model, Hata ModelPath loss model, OKUMURA Model, Hata Model
Path loss model, OKUMURA Model, Hata Model
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Introduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfIntroduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdf
 
Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth Reinforcement
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)
 
Worksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxWorksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptx
 
Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...
 
Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)
 
Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 

Bmv roof fan

  • 2. www.brookvent.co.uk BROOKVENT has over 30 years of experience in the ventilation industry, the design and manufacture of high quality equipment for mechanical and window ventilation. Based on long-term experience, we know the precise needs of our Clients and we are able to propose customized solutions. BROOKVENT offer includes complete ventilation systems designed for single and multi-family houses, including: —— roof and duct fans, as well as many other solutions, together with fixed pressure control module CSR-B, —— window aerators (hygrocontrolled, pressure controlled, manual and built-in- windows aerators) —— on-wall aerators, —— air cycle recuperators - heat recovery ventilation, —— ventilation grates (hygro- and pressure controlled), BROOKVENT is the supplier of energy efficient ventilation systems. It performs its operation to global scale - BROOKVENT provides its products to clients from Baltic Sea countries, China, New Zealand and USA. Implementation of energy efficient forced and window-based ventilation systems of BROOKVENT guarantees comfort of everyday use and ensures healthy living conditions.
  • 3. www.brookvent.co.uk BMV EC fans BMV AC fans BMV Roof fans
  • 4. www.brookvent.co.uk The roof fan is designed for external mounting on the ends of ventilation ducts in residential, commercial and industrial buildings with little air pollution in the form of solid particles. The fan can be coupled with CSR-B controller that will ensure a stable operation of the ventilation in all conditions, and precisely according to the design guidelines. —— 3 models to choose from: 1.9, 2.2, 2.5 —— Horizontal air throw. —— Structure made of plastic material. BMV fans with EC motor BMV 1.9 EC 2.2 EC 2.5 EC Power [V/Hz] 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz Maximum power consumption [W] 99 168 202 Maximum current consumption [A] 0.7 1.1 1.3 Operating temperature range [ºC] from -20 to 60 from -20 to 50 from -20 to 50 Weight (kg) 3.2 6.0 6.2 Protection closure class / Insulation Class IP44 cl.B IP44 cl.B IP44 cl.B TECHNICAL DATA ELECTRICAL CONNECTION DIAGRAM DESCRIPTION FEATURES DIMENSIONS BMV 1.9 EC BMV 2.2 EC BMV 2.5 EC —— Roof protecting against rainfall made of UV resistant material in grey. —— Steel mounting plate equipped with a connector. —— EC motor, equipped with terminal box for electrical connection, for optimal operating conditions i.e.: air flow, pressure, noise emissions and power consumption. —— Possible automatic adjustment using the multi function CSR-B controller, e.g. in the constant pressure system with a choice of performance characteristics. RED/OUTLET +10 V L-BROWN PHASE WHITE/TACHO OUTLET YELLOW/INLET 0-10 V BLUE/GROUND PE-YELLOW-GREEN GROUND N-BLUE NEUTRAL
  • 5. www.brookvent.co.uk PERFORMANCE CURVES PERFORMANCE CURVES BMV 1.9 EC BMV 2.2 EC Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 34 44 58 67 70 67 63 54 74 OUTLET 36 47 60 69 74 74 66 55 78 2 INLET 31 41 53 65 67 67 65 53 73 OUTLET 35 42 56 64 71 74 68 57 77 3 INLET 32 42 56 65 68 65 61 52 72 OUTLET 34 45 58 67 72 72 64 53 76 4 INLET 25 35 47 59 61 61 59 47 67 OUTLET 29 36 50 58 65 68 62 51 71 5 INLET 26 36 50 59 62 59 55 46 66 OUTLET 28 39 52 61 66 66 58 47 70 6 INLET 17 27 39 51 53 53 51 39 58 OUTLET 21 28 42 50 57 60 54 43 63 7 INLET 18 28 42 51 54 51 47 38 58 OUTLET 20 31 44 53 58 58 50 39 62 Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 47 55 69 73 75 69 63 54 78 OUTLET 52 57 71 74 79 78 68 61 83 2 INLET 37 47 59 65 69 66 62 52 72 OUTLET 37 47 64 65 74 74 64 55 78 3 INLET 42 54 65 69 71 64 58 49 74 OUTLET 47 56 67 70 76 74 64 57 79 4 INLET 32 43 53 59 63 59 55 42 66 OUTLET 32 44 56 61 67 67 58 48 71 5 INLET 37 53 58 62 64 57 50 38 67 OUTLET 39 55 60 63 68 66 55 49 71 6 INLET 27 40 45 51 53 49 42 28 57 OUTLET 27 43 46 53 58 58 43 41 62 7 INLET 33 46 49 53 54 47 40 26 58 OUTLET 34 48 51 55 58 55 43 42 62 ACOUSTICS ACOUSTICS
  • 6. www.brookvent.co.uk PERFORMANCE CURVES ACCESSORIES BMV 2.5 EC 8 Acoustic silencers Return flapRoof bases Electrical accessories ACOUSTICS PERFORMANCE CHARACTERISTICS Model [V] [rmp] [W] [A] [m3/h] Sound pressure level at a distance of 3m* BMV 1.9 EC 10 3270 99 0.7 760 61 8 3130 89 0.6 730 60 6 2650 55 0.4 620 57 4 2060 29 0.2 480 51 BMV 2.2 EC 10 2900 168 1.1 1270 64 8 2490 111 0.7 1090 60 6 1940 56 0.4 850 53 4 1370 24 0.2 590 44 BMV 2.5 EC 10 2650 202 1.3 1490 63 8 2300 140 1.0 1290 59 6 1800 73 0.6 1000 53 4 1290 33 0.3 720 44 Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 40 52 65 71 72 68 63 58 76 OUTLET 42 53 66 70 77 75 66 59 80 2 INLET 35 46 63 65 68 66 62 53 72 OUTLET 36 47 62 65 73 72 66 56 77 3 INLET 38 50 63 65 69 63 58 53 72 OUTLET 38 50 62 66 74 70 61 54 76 4 INLET 31 42 57 60 61 60 54 44 66 OUTLET 32 43 56 60 66 66 58 47 70 5 INLET 34 47 57 60 62 56 51 45 66 OUTLET 35 48 57 61 66 62 53 45 69 6 INLET 29 48 47 50 53 50 40 32 57 OUTLET 27 49 46 51 58 58 43 34 62 7 INLET 29 48 48 52 52 47 39 34 57 OUTLET 29 45 47 53 56 53 42 33 60 8 INLET 33 43 55 67 69 69 67 55 74 OUTLET 37 44 58 66 73 76 70 59 79 * Measured at point 8, 2, 4, 6 on the performance curve.
  • 7. www.brookvent.co.uk The roof fan is designed for external mounting on the ends of the ventilation ducts in residential, commercial and industrial buildings with little air pollution in the form of solid particles. The fan can be coupled with CSR-B controller that will ensure a stable operation of the ventilation in all conditions and precisely according to the design guidelines. —— 3 models to choose from: 1.9, 2.2, 2.5 —— Horizontal air throw. —— Structure made of plastic material. BMV fans with AC motor BMV 1.9 AC 2.2 AC 2.5 AC Power [V/Hz] 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz 1 ~ 230 V±10% 50Hz Maximum power consumption [W] 61 151 222 Maximum current consumption [A] 0.3 0.6 1.0 Operating temperature range [ºC] from -40 to 70 from -40 to 60 from -40 to 60 Weight (kg) 3.4 6.4 6.4 Protection closure class / Insulation Class IP44 cl.B IP44 cl.F IP44 cl.F TECHNICAL DATA ELECTRICAL CONNECTION DIAGRAM DESCRIPTION FEATURES DIMENSIONS BMV 1.9 AC BMV 2.2 AC BMV 2.5 AC —— Roof protecting against rainfall made of UV resistant material in grey. —— Steel mounting plate equipped with a connector. —— AC motor fitted with automatic thermal protection reset. —— Possible automatic adjustment using the multi function CSR-B controller, e.g. in the constant pressure system with a choice of performance characteristics. BROWN RED BLACK/NEUTRAL BLUE/PHASE YELLOW-GREEN GROUND
  • 8. www.brookvent.co.uk BMV 1.9 AC BMV 2.2 AC Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 32 45 58 59 64 60 53 41 67 OUTLET 32 45 59 60 66 65 55 43 70 2 INLET 27 38 58 56 62 63 58 44 67 OUTLET 29 40 60 59 64 68 61 46 71 3 INLET 28 41 54 55 60 56 49 37 64 OUTLET 28 41 55 56 62 61 51 39 66 4 INLET 24 35 55 53 59 60 55 41 64 OUTLET 26 37 57 56 61 65 58 43 67 5 INLET 22 35 48 49 54 50 43 31 57 OUTLET 22 35 49 50 56 55 45 33 60 6 INLET 18 29 49 47 53 54 49 35 58 OUTLET 20 31 51 50 55 59 52 37 61 Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 44 53 66 70 72 65 59 52 75 OUTLET 45 55 68 72 77 74 65 58 80 2 INLET 35 44 58 66 70 66 62 53 73 OUTLET 34 45 63 67 74 74 65 57 78 3 INLET 41 50 63 67 69 62 56 49 72 OUTLET 42 52 65 69 74 71 62 55 77 4 INLET 32 41 55 63 67 63 59 50 70 OUTLET 31 42 60 64 71 71 62 54 75 5 INLET 36 45 58 62 64 57 51 44 67 OUTLET 37 47 60 64 69 66 57 50 72 6 INLET 26 35 49 57 61 57 53 44 64 OUTLET 25 36 54 58 65 65 56 48 69 PERFORMANCE CURVES PERFORMANCE CURVES ACOUSTICS ACOUSTICS 1 3 4 5 6 1 3 4 5 6
  • 9. www.brookvent.co.uk BMV 2.5 AC PERFORMANCE CURVES ACOUSTICS Hz 63 125 250 500 1000 2000 4000 8000 LwA 1 INLET 42 53 66 70 72 67 60 53 76 OUTLET 45 55 70 73 77 74 64 56 80 2 INLET 34 46 66 68 69 68 64 55 74 OUTLET 35 46 66 69 75 74 67 57 79 3 INLET 37 48 61 65 67 62 55 48 71 OUTLET 40 50 65 68 72 69 59 51 76 4 INLET 30 42 62 64 65 64 60 51 71 OUTLET 31 42 62 65 71 70 63 53 75 5 INLET 31 42 55 59 61 56 49 42 65 OUTLET 34 44 59 62 66 63 53 45 69 6 INLET 24 36 56 58 59 58 54 45 64 OUTLET 25 36 56 59 65 64 57 47 69 ACCESSORIES Acoustic silencers Return flapRoof bases Electrical accessories PERFORMANCE CHARACTERISTICS Model [rmp] [W] [A] [m3/h] Sound pressure level at a distance of 3m [dB(A)]* (ºC) (Kg) BMV 1.9 AC 2520 61 0.3 600 53 -40 / +70 3.4 BMV 2.2 AC 2670 151 0.6 1170 60 -40 / +60 6.4 BMV 2.5 AC 2650 222 1.0 1500 61 -40 / +60 6.4 1 3 45 6 * Sound pressure level measured at a distance of 3m, in the fan mounted on a flat roof (Operation point no. 2 on the performance curve).
  • 10. www.brookvent.co.uk Electrical accessories: CSR-B controller BS 1.8 regulator BR-1/010 regulator BW regulator LK 12A service switch PDI/PDT roof base PDDS I/T roof base with double-sided suction Base plate with the PP connector Acoustic silencers: TLE, TLS CAR return flap LE flexible coupling Air filter KFO Accessories
  • 11. www.brookvent.co.uk EXAMPLES OF INSTALLATION 1. CSR-B 2. Roof base 3. Base plate with the connector 4. Return flap 5. LE flexible coupling 6. flexible TLE or rigid TLS silencer 7. ventilation duct 1 1 1 2 2 7 7 7 4 4 4 5 5 5 3 777 666
  • 12. www.brookvent.co.uk CSR-B controller ELECTRICAL ACCESSORIES DESCRIPTION OF OPERATION The CSR-B drivers are the regulators of the constant pressure intended for cooperation with duct and roof fans with AC and EC motors. By smoothly adjusting fan speed, they ensure constant vacuum before or constant pressure behind the fan. The built-in PI system with adjustable settings allows to adjust the dynamics of pressure regulation. . The CSR-B is available in two versions: —— CSR-B XC1 —— CSR-B UL EC Both controllers are based on the PI regulator. The XC1 model has a built-in transistor speed regulator (for AC motors) and more extensive interface (more options). Both controllers have the option of setting a fixed fan speed and programmable upper and lower limits for fans settings. FEATURES —— The CSR-B controller allows for a smooth control of fan speed in order to ensure constant under-pressure or overpressure value in the ventilation duct. It provides a stable performance of the system, regardless of the degree of opening of the ventilation grates. It is adjusted to work with fans and grates from BROOKVENT. —— The night setting allows to reduce the vacuum value set. It makes the system comfortable to use in time, by reducing the noise when intensive exchange of air is not necessary. —— In the XC1 version, it is possible to program settings in day, night and weekly modes: 5+2d; 7d. In 7d mode, you can set 4 zones (settings). A built-in weekly timer acting as a clock controlling the entire system. This function allows to enter e.g. night settings. —— The built-in LCD or OLED display (UL EC version) with an easy-to-use control keypad that allows you to read all the performance parameters of the system and quickly change settings. —— Integrated support for MODBUS RS485 communication protocol, for remote viewing of system performance parameters and its change of settings via master Building Management System (BMS). The function is available in the XC1 model. —— CSR-B indicates the following alarms: The CSR-B-XC1 mode: – serial communication block alarm, – real time clock alarm – pressure regulation failure alarm, – transducer pressure alarm, – no serial communication alarm. The CSRB-UL EC: – settings saving failure alarm – transducer pressure alarm, – RTC module error alarm. —— The power switch on the housing allows maintenance work with the fan (CSR-B-XC1). TECHNICAL DATA CSR-B consists of two fundamental function blocks: —— speed regulator (phase or transistor control) —— pressure measurement block (development of control for speed control, converter or EC fan). Parameter Value Power Supply 230 V AC / 50 Hz Maximum current adjustment 2 A Housing dimensions 200x150x75 Housing ABS plastic Weight 920 g Type of motor control Transistor Pressure measuring range ±996 Pa Operating temperature -25÷60°C Degree of protection IP54 Mounting Wall mounting Digital inputs Digital mode input Digital outputs Potential-free relay output Analogue output 0-10 V engine speed regulator control output Control method Control keypad, built-in LCD display CSR-B-XC1 CONTROLLER FOR FANS WITH AC AND EC MOTORS.
  • 13. www.brookvent.co.uk CSR-B-UL EC CONTROLLER FOR FANS WITH EC MOTORS. The CSR-B-UL controller allows for smooth speed control of the fan with EC motor, in order to ensure the required vent air stream and the specified vacuum value in the exhaust duct. Parameter Value Power Supply 230 V AC / 50 Hz Housing dimensions 115x65x55 Housing ABS plastic Weight 200g Type of motor control 0-10V output Pressure measuring range ±996 Pa Operating temperature -25÷60°C Degree of protection IP65 Mounting Wall mounting Digital inputs Mode selection digital input Digital outputs - Analogue output 0-10 V fan control output type EC Control/Regulation method Control keypad, built-in OLED graphical display Speed regulator BS 1.8 Voltage (V) Dimensions L x W x H (mm) Weight (kg) Current consumption (A) Safety class Maximum ambient temperature (°C) 1 ~ 230 78x78x63 0.11 1.8 IP 40 35 TECHNICAL DATA W R APPLICATION Applied in BMV AC to turn on / off and regulate fan speed. It is possible to control several fans, if the generally used current does not exceed the accepted limit for current consumption in the regulator. DESIGN AND CONTROL The regulator stands out for its precise control. You can turn it on/off using the control knob. Regulation starts from the minimum possible voltage point (at which the fan rotates firmly) up to the maximum point. The minimum speed point can be set by setting the regulated potentiometer. The housing is made of plastic. SECURITY Input circuit in speed controller is protected against overload (load) by the replaceable fuse. The regulator is fitted with a high frequency interference filter. MOUNTING The regulator is intended for wall mounting. It can be surface or flush mounted. The necessary accessories are supplied in the set - a mounting box.
  • 14. www.brookvent.co.uk APPLICATION It is intended for smooth BMV EC fan motor speed regulation. DESIGN AND CONTROL Switch housing is made of plastic. You can turn it on/off using the control knob. It can be regulated from minimum to maximum value. MOUNTING The regulator is intended for wall mounting. Standard version is supplied with flush mount box. Surface-mount is possible with MKN-3 box supplied on request. BR-1/010 switch BR-1/010 Voltage (V) 10-48 V DC Tracking signal (V) 0-10 Maximum current consumption (mA) 5 mA Dimensions AxBxC (mm) 78x78x63 Maximum ambient temperature (° C) 35 Safety class IP 40 Weight (kg) 0.12 TECHNICAL DATA MOUNTING BOXES: Electrical connection diagram MKN-3 for surface mounting (Optional) MKV-4 for flush mounting (supplied as standard) Marks: W – Fan; R – BR-1/010 Regulator
  • 15. www.brookvent.co.uk BW transformer regulator to adjust the speed of single-phase fan motors, hot pluggable, controlled with voltage. Mounted in industrial ventilation or heating systems. A knob located on the housing panel allows to set the speed at 5 levels. Equipped with an independent switch, indicating switching with backlight. Made in the 2nd isolation class. Degree of protection IP30 or IP54. Maximum ambient temperature 40°C. Thermal class of insulation B (130°C). Made in accordance with EN 61558-2-13. Range of SEC currents: 0.5 - 14 A Range of PRI: 230 V, 50/60 Hz SEC voltage range: 5-Level speed control BW fan speed transformer regulator Ur (V) / Ir (A) Dimensions (mm) Type Type BW 0.5 BW 0.5 BW 1.5 BW 1.5 BW 3.0 IP54 BW 3.0 IP54 BW 7.0 BW 7.0 BW 14.0 BW 14.0 BW 2.0/1 IP54 BW 2.0/1 IP54 BW 5.0 BW 5.0 BW 10.0 BW 10.0 1 1 2 2 3 3 4 4 5 5 Upri (B) Weight (kg) Current (A) Mounting 0.5 M4 1.5 M4 3 M4 7 M6 14 M6 230 0.7 230 1.50 230 2.50 230 5.50 230 10.50 2 M4 5 M6 10 M6 230 2.30 230 4.50 230 8.50 110/0.5 70 115/1.5 96 115/2.2 96 80/6.0 145 80/8.0 147 BW 0.5 BW 0.6 – – 230/1.5 148 230/2.0 148 230/3.0 148 230/5.0 155 230/7.0 155 230/10 255 230/14 255 170/0.5 111 135/1.5 166 135/1.5 166 105/4.3 210 105/9.5 277 230/0.5 77 155/1.5 91 155/2.8 91 135/6.6 145 135/11 155 – – 180/1.5 78 180/3.0 78 170/7.0 100 170/12.5 113 115/1.0 96 80/4.0 145 80/6.5 147 135/2.5 166 105/6.3 210 105/7.5 277 155/1.7 91 135/4.6 145 135/8.5 155 180/2.0 78 170/5.0 100 170/10.0 113 TECHNICAL DATA BW 1.2/1 BW 1.5/1; 2.0/1; 3.0; 5.0; 7.0; 10.0; 14.0 Regulator connection diagram:
  • 16. www.brookvent.co.uk LK 12 Aservice switch Complete device in housing YES Number of poles 3 The number of auxiliary switch contacts 0 The number of auxiliary NC contacts 0 The number of auxiliary NO contacts 0 Model On/off switch Suitable for installation in switchboards NO Suitable for front 4-hole mount NO Suitable for intermediate fitting NO Suitable for flat mounting YES The type of the switching element Knob The type of primary circuit adapter Screw connection Degree of protection (IP) IP65 Positioned on 0 YES Rating continuous current Iu [A] 12 TECHNICAL DATA Universal service switch, 12 A, 3-pole. For all types of single and three-phase motors. DESCRIPTION
  • 17. www.brookvent.co.uk DIMENSIONS PDI/PDT roof base Roof base for flat roofs is made of galvanized steel sheet. There are two types of bases available: PDI - insulated, it has 10 mm thick (PUR foam) insulation inside, which prevents condensation and PDT-silencing with 50 mm thick (mineral wool) insulation. Flange around the base allows to mount it securely to the roof. DESCRIPTION PDDS I/T roof base with double-sided suction Base plate with the PP connector Roof base with double-sided suction for flat roofs is made of galvanized steel sheet. There are two types of bases available: PDDS - insulated, with 10 mm thick (PUR foam) insulation inside, which prevents condensation and PDDS T - silencing with 50 mm thick (mineral wool) insulation. Convenient mounting elements allow to anchor the basis in the roof or attach it to the profiles. Base plate with the PP connector (optional) Element to close the roof base bottom fitted with a connector of 160, 200 or 250 mm diameter. DESCRIPTION DESCRIPTION 300/400/500
  • 18. www.brookvent.co.uk Ød1 Nom [mm] L [mm] Silencing (dB) for the frequency (Hz) 125 250 500 1000 2000 4000 8000 160 600 13 19 18 18 16 7 6 200 600 14 17 12 13 14 7 5 250 600 15 15 10 12 14 6 5 Ød1 Nom [mm] L [mm] Silencing (dB) for the frequency (Hz) 125 250 500 1000 2000 4000 8000 160 1200 17 29 28 30 30 23 11 200 1200 24 30 23 26 27 16 10 250 1200 22 23 18 22 19 8 7 TLE flexible acoustic silencers DESCRIPTION TLE flexible acoustic silencer is made of a perforated cable. The applied insulation is 25 mm thick and it is covered with aluminium and polyester coating. The silencer is connected using metal flanges which are used as nipple. They are available in two lengths of 600 mm and 1200 mm. Silencers can be made on request: with seals made of EPDM, with sleeve flanges or of different lengths. INSULATION The type of insulation: glass wool. The type of insulation: From the circle - flexible. TEMPERATURE RANGE -20°C to +140°C THERMAL INSULATION OF MINERAL WOOL: Lambda = 0.034 W/m x k in 24°C. PRESSURE LOSSES: According to the attached diagram. FIRE RESISTANCE: Silencers made of non-combustible materials. Version - Example of marking: TLE - threaded - this is a standard make TLE-L - threaded with a mounted seal made ofEPDM TLE-F - sleeve Example of marking Product Code: TLE - 25 - aaa - bbb type Thickness of insulation* Ø d1 L * 50 mm insulation is available upon request
  • 19. www.brookvent.co.uk TECHNICAL DATA: Pressure losses calculated on the extended and simple silencer. The length of the silencer = 1.0 m 1 Pa = 0.01 mbar = approximately 0.1 mm WG flow [m3 /h] Pressure losses in flexible silencers TLE-25. Silencer’spressureloss[Pa/m] diameter100mm flow speed 15 m/s
  • 20. www.brookvent.co.uk DIMENSIONS TLS rigid acoustic silencers As a standard, silencers are supplied with rubber seal. Inside, it is filled with mineral wool that is 50 mm thick. Example of marking Product Code: TLS - 50 - aaa - bbb type thickness of insulation Ø d1 L For diameters d1 ≤ 315 mm Cross-section for silencers: TLS made with 50 mm thick insulation and concerns the following diameters: D-100, D-125, D-160, D-200, d-250. These are silencers made with pressed lids. DESCRIPTION Description Ød1 Nom [mm] D Nom [mm] L [mm] Silencing (dB) for the frequency (Hz) Weight [kg] 125 250 500 1000 2000 4000 8000 TLS-50-160-300 160 250 350 3 9 20 33 35 16 18 3 TLS-50-160-500 160 250 550 6 12 23 36 38 19 21 5 TLS-50-160-600 160 250 650 7 14 24 37 39 21 22 6 TLS-50-160-900 160 250 950 10 16 26 40 42 23 25 8 TLS-50-160-1000 160 250 1050 11 17 28 41 43 24 26 8 TLS-50-160-1200 160 250 1250 10 TLS-50-200-300 200 300 350 2 7 16 31 31 15 16 4 TLS-50-200-500 200 300 550 5 10 19 34 34 18 19 6 TLS-50-200-600 200 300 650 6 11 20 35 35 19 20 7 TLS-50-200-900 200 300 950 8 13 23 38 38 22 23 10 TLS-50-200-1000 200 300 1050 9 15 24 39 39 23 24 11 TLS-50-200-1200 200 300 1250 12 TLS-50-250-500 250 355 550 4 9 18 29 27 15 16 9 TLS-50-250-600 250 355 650 5 11 19 30 28 16 18 11 TLS-50-250-900 250 355 950 8 13 22 33 31 19 20 14 TLS-50-250-1000 250 355 1050 9 14 23 33 32 20 21 12 TLS-50-250-1200 250 355 1250 11 17 25 35 34 21 23 17 TLS-50-250-1500 250 355 1550 12 18 26 37 35 23 24 20 TLS-50 - 50 mm of insulation DIMENSIONS Description Pressure drop (Pa) for flow speed (m/s) 2 4 6 8 10 TLS-50-160-300 0.24 0.96 3.84 6.00 8.64 TLS-50-160-500 0.25 0.99 3.96 6.18 8.90 TLS-50-160-600 0.25 1.02 4.07 6.36 9.16 TLS-50-160-900 0.29 1.15 4.61 7.20 10.37 TLS-50-160-1000 0.31 1.23 4.92 7.68 11.06 TLS-50-160-1200 TLS-50-200-300 0.17 0.67 2.69 4.20 6.05 TLS-50-200-500 0.17 0.69 2.76 4.32 6.22 TLS-50-200-600 0.18 0.72 2.88 4.50 6.48 TLS-50-200-900 0.22 0.86 3.46 5.40 7.78 TLS-50-200-1000 0.24 0.94 3.76 5.88 8.47 TLS-50-200-1200 TLS-50-250-500 0.18 0.74 2.96 4.62 6.65 TLS-50-250-600 0.19 0.77 3.07 4.80 6.91 TLS-50-250-900 0.23 0.91 3.65 5.70 8.21 TLS-50-250-1000 0.25 0.99 3.96 6.18 8.90 TLS-50-250-1200 0.35 1.39 5.57 8.70 12.53 TLS-50-250-1500 0.40 1.58 6.34 9.90 14.26 TLS-50 - 50 mm of insulation DROPS IN PRESSURE
  • 21. www.brookvent.co.uk DESCRIPTION Tight CAR return flap is mounted inside the ventilation duct. It effectively protects against unwanted phenomenon of vent air reverse. APPLICATION: It is particularly suitable for ventilation systems in apartment buildings, on vents from cooker hoods, as well as in other ventilation systems. CONSTRUCTION: Return flap is made of galvanised steel, throttle blinds are made of aluminium. It is equipped with an internal seal that ensures its tightness and reduces the noise of the blinds. The flap also has an external seal made of foam, that provides easy installation and sealing inside the vent duct. Type Ød (mm) L1 (mm) L2 (mm) CAR 160 155 66 81 CAR 200 195 72 93 CAR 250 247 120 145 DIMENSIONS CAR return flap
  • 22. www.brookvent.co.uk APPLICATION Flexible couplings are intended to eliminate vibrations transmitted from the fan or other ventilation devices to the ventilation system and to partially compensate ventilation ducts created as a result of temperature extensions. Applied in ventilation devices in the temperature range from -40ºC to +80ºC. CONSTRUCTION Flexible couplings form 2 mounting frames joined together with a material that isolates from vibration. MOUNTING Installation of the flexible couplings into the ventilation system is carried out using the mounting frames. They are mounted using galvanized bolts and clamps. LE flexible coupling Series Flange diameter (mm) LE 160; 200; 250; Dimensions (mm) Type LE 200 LE 250 LE 160 ØD L 130 130 130201 0.28 251 0.35 161 0.22 Weight (kg) KFO duct filter DESCRIPTION KFO duct filter is applied to filter air in round ventilation ducts. The KFO duct filter is a box made of galvanized steel, closed from the top with clips. The housing has mounting connectors with seals, made of EPDM. Special design of the KFO filter allows for easy exchange of the filter cartridge. In the standard version, it is delivered with EU3 class filter. KFO duct filter can be equipped with a filter cartridge of EU3 or EU5 class. You can order the filter cartridge as KFO-I filter frame or KFO-W creased filter, which has filtering matt secured with galvanized steel wire mesh. DIMENSIONS DIMENSIONS Type Qd (mm) AxA (mm) B (mm) KFO-160 160 210 160 KFO-200 200 250 160 KFO-250 250 300 160 Example of marking Product Code: KFO - Qd type diameter
  • 23. www.brookvent.co.uk All rights reserved. This material is for information only and it is not a commercial offer. Brookvent Polska sp. z o.o. assumes no responsibility for any errors made in the publication and reserves the right to make amendments. Version: v 1.0 2018
  • 24. www.brookvent.co.uk Address: Kościuszki 14-16 Oborniki Śląskie 55-120 M: hello@brookvent.co.uk T: +44 (0)28 9061 6505 F: +44 (0)28 9061 6505 www.brookvent.co.uk