SOLAR POWER
CLARIFICATION OF THE SOLAR
ENERGY POWER GENERATING
Following two type of the solar energy power generating
• Grid-off solar energy power generating
Main used in the area where is no electricity supply or
the telecommunication station which is faraway from the
electricity net or the wireless places.
Key components:solar panel、battery、intelligent controller、
inverter 、electricity distribution and anti-lighting system. (electricity
distribution is close to the active load).
Advantages:offer the independent electricity net which will not
restricted by the local public electricity net.
Disadvantages:much waste of the energy resources or can
controller the use of the solar energy resources. the electricity use is high
restricted by the weather condition, the low efficiency of use and high
investment, a little low system life span (especially say the batter’s life
span).
• Grid-On PV System
Main use in the place where the city electricity distribution net. It is
the lead direction of New energy from home and all over the world.
Key components: solar panel、grid-on inverter、 electricity distribution and
anti-lighting system (much simple ).
Advantages:high efficient use of the system,long life span;the
investment cost is some lower;the use of the electricity will not restricted by the
system itself and the weather condition influence.
Disadvantages:the return of the electricity powered by solar will be
restricted by the local public electricity net.
THE INDEPENDENT GRID-OFF SOLAR ENERGY
POWER GENERATING SYSTEM DETAILED
INTRODUCTION
SOLAR PANEL/MODULE
Solar Panel is a generating equipment which
can transfer the solar light energy to the DC
electricity energy. It is made as a single panel
when use according to the different
requirements on the power output and its
voltage. It also can be used as several solar
panel connected in series (which is to meet
the demands on voltage) and connected in
parallel (which is to meet the demands on
current). this way can make as the
panel/modules arrays to supply much higher
electricity demands. the solar panel/modules
has many advantages such as high power
efficiency on area,long life span, and high
reliability,during the use period, the loss of
the output power is less than 20%.
THE FEATURES OF VOLT-
AMPERE FOR PV SOLAR PANEL
Generally speaking,the solar
panel electricity generating is
increased in percentage with
the intensity of the sunlight.
With the surface temperature
increased of the solar panel
slightly decreased.
The so-called general of the
solar panels that power is in
the sunlight intensity of 1000
W/M2, components, surface
temperature is 20 ℃, Imax *
Umax value.
PHOTOVOLTAIC MODULE INSTALLATION
ANGLE
Photovoltaic module installed inclination should be guaranteed to receive the
maximum sunlight exposure, in normal circumstances components and the
horizontal direction for the local latitude ± 5 °to 10 °. That is, when the reduction
in the summer, when the increase in the winter. If a fixed angle brackets, the use of
local latitude tilt angle. For example, the city of Shantou to 23.42 °latitude.
BATTERY DISCHARGE CURVES
• 10 hour rate (0.1 CA), 5 hour rate (0.17 CA), 3 hours rate (0.25 CA) discharge
termination voltage: 10.8 V /set; 1 hour rate (0.55 CA) discharge termination
voltage: 10.5 V / set.
• Termination of battery discharge voltage minimum not more than 9.6 V / only
to ensure that the battery will not over-discharge.
THE RELATIONSHIP BETWEEN BATTERY LIFE
AND TEMPERATURE CURVE
In the environmental temperature 15 to 25 ℃ and the proper use of circumstances, the
use of rechargeable batteries floating design life of 5 to 8 years. Environmental
temperature on the battery life is greatly affected when the ambient temperature every
10 ℃ increased battery life of about 50 % reduction. Therefore, to extend battery life, the
battery should be maintained as far as possible in 15 to 25 ℃.
BLOCK DIAGRAM OF THE SOLAR
CONTROLLER
SMALL PV POWER INTELLIGENT CONTROLLER
Characteristics:
1. Solar protection reverse: solar + and - to the anti-polarity,
after correct, it can continue to use.
2. Battery Open circuit protection: If the battery breaks, and
batteries can be rechargeable normally, the controller will be
limited at both ends of load voltage, to ensure that the load is
not injury, if at night or solar battery not be chartered, the
controller due to its own access to electricity, will not have
any action;
3. Overcharge protection: protection of charge voltage higher
than the voltage, automatic shutdown of rechargeable
batteries. When the voltage then swap to maintain voltage,
battery enter Float state, when less than restoring voltage
Float closed, are sufficient to enter the state. Have sufficient
voltage protection and restoration of both temperature
compensation voltage Float;
4. When the battery voltage is lower than the protection of
voltage, the controller automatically shut down output in
order to protect the battery from damage;
5. Over voltage protection: When high voltage, output shut down
automatically to protect against electrical damage. A charge,
the release of over-voltage protection are delayed action to
prevent the disoperation.
6. With temperature compensation function
7. Variety of control options functions: general charge and
discharge mode, light is turned off mode, the opening of the
shutdown mode
Small PV power
Intelligent Controller
5A 、10A
MID-POWER PHOTOVOLTAIC CONTROLLER
1.LCD display: LCD shows Users Display System important
information such as the battery voltage, the charge
Current and discharge Current, the operation mode and the
system parameters, system status by the digital and English
2. Automatic / manual / night features: Programmable Load Control
Ways to automatically or manually. Manual, manual load
Open or closed. At this time, the evening function invalid. When
choosing night function, the controller closed in the daytime load
detection evening,
Automatically after a period of time delayed opening load,
regular time, it has been Dynamic load shut down. Regular time
and delay time based programmable Determined;
3. Protection features: over-charged, over-discharged, output
overload, over -Pressure, high temperature protection;
4. Float voltage with the temperature compensation function;
5 fast charging functions: the battery voltage falls below a certain
value, rapid Start charging automatically, the controller will
increase battery power Pressure, when the battery voltage
achieve the desired value, started fast charging When
Countdown procedures, regular time, with rapid charging state.
Therefore, Full use of solar energy.
6. Automatic identification functions: the first power, in accordance
with electrical storage controller Pool automatic identification
terminal voltage is 12 V or 24 V system;
7. Mode: normal charge-discharge mode, light is turned off mode,
- The opening of the shutdown mode.
Mid-Power Photovoltaic Controller
20A、30A
HIGH-POWER PHOTOVOLTAIC CONTROLLER
High-Power Photovoltaic Controller
50A-100A
Standard 4U Cabinets
High-Power Photovoltaic Controller
150A-200A
Standard 6U Cabinets
HIGH-POWER PHOTOVOLTAIC CONTROLLER
Waterproof Outdoor Mount
250A-400A
1200 Standard Cabinets
100A-200A
THE CHARACTERISTICS OF THE HIGH-POWER
PHOTOVOLTAIC CONTROLLER (1)
• DSP chip microcomputer control, the charge and discharge parameters,
temperature compensation coefficient programmable arbitrary , can adapt to
the special requirements of different occasions.
• LCD dot matrix modules that operate in both English and Chinese menu, users can
switch choice;
• Various LED indicator to display photovoltaic charge state and load-off state;
• 9 touch buttons;
• Control circuit totally isolated from the main circuit, high anti-jamming capability;
• 1-18 Road solar input control;
• Real-time display battery voltage, load current, the total current photovoltaic,
Each PV current, battery temperature, the total number of hours photovoltaic
power generation, the cumulative load of electricity, and some like several
dozen parameters;
THE CHARACTERISTICS OF THE HIGH-POWER
PHOTOVOLTAIC CONTROLLER (2)
• the historical data and Statistics show: the number of charge cycles, the number of
discharges, the number of overload, short-circuit number;
Programmable voltage generator start-up and shutdown, secondary load-off voltage, wind
generator unloading and recovery voltage, street photosensitive parameters such as
voltage switch;
• Users can set up a rechargeable battery discharge protection and the protection of the
load-off state;
• With the Second ability to control, that is the main load and secondary load in different
battery voltage electrical point of control;
• Various charge pressure of a "backlash" control functions, to prevent oscillation switch into
the state;
• Protection features: with a rechargeable battery, a discharge, output overload, short-circuit,
surge, solar or battery against a short circuit to the anti-battery at night and a series of
anti-anti-sufficient warning and protection;
• RS232/485 interfaces can be allocated to facilitate long-distance remote, remote control; PC
control software can be measured real-time data, alarm information, change control
parameters, read the daily 30 days maximum battery voltage, battery voltage minimum
daily PV and the total volume of electricity consumed by the daily load accumulated
historical data;
• Parameter settings and the ability to password-protect users may modify password;
THE CHARACTERISTICS OF THE HIGH-POWER
PHOTOVOLTAIC CONTROLLER (3)
• Warning: over-voltage, under-voltage, overload, short-circuit protection, such as alarm;
• Multi-channel output report to the police or passive control contact: a rechargeable
battery, a battery discharge, Diesel boot control, load disconnect, controller fault;
other user-selectable backup alarm contact, such as flood alarm;
• Work step by step-ladder pattern of limited mode, PWM mode, the opening of the
off-model-turned-down mode, the clock control mode, the light is turned off early-
model, which is the model for the first two occasions common load, After four
model load occasions against the lights, all the length and timing clock delay can be
set up;
• Users can also set up parameters including: are charging pressure, Float voltage,
voltage absorption launched voltage regulator dynamic coefficient of static
coefficient Regulators are filling state time and state absorption time.
• Do not brown-out real-time clock function, display and set the clock;
• Lightning: According to system requirements, install different levels of mine devices;
• A temperature compensation function;
• Portfolio ingenious: alone, but also complementary components scenery, inverter
control integration models
THE CHARACTERISTICS OF THE INVERTER
★High reliability for new energy generation power plants are often installed
in the mountain and pastoral areas, border, islands, and other traffic
inconvenience, if there are large temperature difference between day and
night, high-altitude and thin air caused by heat, insulation, as well as facing
long transport , once a power failure, repair, the more difficult and
therefore the reliability of the power supply to more stringent requirements.
★ High efficiency, the current generation of new energy sources, high cost
per unit of electricity, the solar panels is expensive, improving the efficiency
of inverter power than improving the efficiency of solar panels more
efficient and more economical.
★ Specifically for high altitude, cold zone designed to be at an altitude of
6,000 m and -40 ℃ use of ambient temperature (Note: the need for the use
of descending).
★ With the discharge of the battery protection, photovoltaic power plants,
wind power is often used for the power station on the battery charge
controller, real-time management of discharge, the battery will be over-
discharge protection with its own power inverter power supply devices to
achieve, not only simplify circuit, reduce costs, but also can avoid the
conventional DC motor controller-off arising from the widening arc, thus
enhancing the reliability of the system.
BLOCK DIAGRAM OF THE
INVERTER
ON THE LOAD CONFIGURATION
• Equipment (or other electrical appliances used) on the
plate are generally rated current, voltage data, they are
multiplied together to receive VA value corresponding
power. Users must use carefully inspect the load power in
order to avoid overload. With the general operation of
electrical appliances in the state, especially in the standby
power than the actual state of the mark on some low
power users to be used in the use of electrical appliances
and of the nominal power, is starting at the same time
consider the impact of current, best left 30 % of the
power cushion to ensure reliable power supply;
• The load should be considered motor-5 ~ 7 times
the cushion to impact current.
INVERTER POWER PROTECTION
protection instruction remarks
Output Over-
load
protection
Power load more than 150%, 10 seconds
after the shutdown output delay
Need to be reset
shutdown
Short circuit
protection If the output short circuit, inverter power will be
shut down automatically
To protect
against the
importation
Input DC voltage inverter to the anti-polarity, the
inverter will be automatically protected
Automatically
reset, that is, after
the failure to
eliminate the
output will
automatically
resume
Under-voltage Input DC voltage is lower than the under voltage
point, inverter power will be shut down
automatically
Over voltage
Input DC voltage is higher than the pressure point,
inverter power will be shut down automatically
Over heating
protection
Inverter Power Supply chassis temperature over
75 ℃, the output will be shut down automatically
THE DISCHARGED PROTECTION AND
RECOVERY
• Protection of the over-discharged, the battery voltage required to return to work at 226 V or
above can start again. Backlash is set up in order to prevent voltage under voltage system in
the near oscillations, as shown in Figure 6.1.
• Power attention when booting the first time if the battery voltage is in the release point and
resume work between power will be in the state and show under voltage shutdown.
• Over-discharged protection value and the restoration of working voltage values for the
default settings (subject to user requirements set), general without adjustment. If and where
adjustments, in the PC board (SNMC) found on the potential for VR2 (Figure 7.3 Position 6),
such as lowering the release point, then clockwise adjustment; such as raising the release
point, the anti-clockwise adjustment. Potentiometer adjustment semi-circle, the
corresponding change in value of the release point about 7 V, for reference purposes only.
Picture 6.1
THE MAINTAINABILITY OF PHOTOVOLTAIC
POWER SYSTEM’S COMPONENTS
1 Some products photovoltaic power system components can be
repaired after used again, known as maintenance parts, but
some parts missing validity beyond repair or restoration costs
are too high, these components as a non-repair components,
the following table lists the photovoltaic power supply
Attributes of components in the system.
Can be repaired non-repair
Inverter Solar panel
Controller Maintains free lead acid battery
PV water Pump DC lamps
Wind turbine Arrester, fuses, wires
… … … …
THE MAINTAINABILITY OF
PHOTOVOLTAIC POWER SYSTEM’S
COMPONENTS
Actually in photovoltaic power system , some components can be maintained but some can not be.
Such as solar panels, maintenance-free batteries, they are difficult to repair after the failure, which
is called as the non-maintenance components, which are directly dealt with a narrow reliability index,
the main reliability, failure rate, the average life expectancy of three indicators, reliability, R (t) refers
to products (or parts) under the conditions set forth in that time to complete the function of the
probability of failure rate λ (t) refers to the moment t work has not yet Failure products, in the
moment unit time in the probability of failure; average life expectancy refers to the use of products
from
the beginning until failure occurred experienced by time.
The controller, inverter power supply can be maintained, such as products or components, and its
main indicators reliability, failure rate and the average time between failures (MTBF) and mean time to
repair faults (MTTR).
The components can be maintained and by the maintenance of the components of PV systems, in
general, should be understood as products can be maintained.
THE DESIGNING OF THE PV GRID-OFF
SYSTEM
CASE:
• Requirements: computers, lighting, radar (emotional) of load, time
uncertain, the daily power consumption about 200 KWH, batteries to
power for three days cloudy.
1. Battery configuration (in accordance with the allocation of work for three rainy days):
Battery groups voltage: 220 V
Capacity needs:
(daily needed electricity × rainy days × 1000) / (battery voltage ×discharge capacity)
Discharge capacity:
In the process of battery usage, the battery capacity released by the percentage of its
rated capacity, known as the discharge capacity. Discharge capacity to the protection of
small batteries, the election is generally recommended 0.5
(200 × 3 × 1000) / (220 * 0.5 * 0.9) = 5754 AH
choose 2 V1000AH battery of a total of five groups of 110pcs, a total of 550pcs.
THE DESIGNING OF THE PV GRID-OFF
SYSTEM
• 2. Solar array configurations:
Need to configure the maximum power to maintain voltage in the vicinity of
220V , Selection of 85 Wp (or other specifications): open-circuit voltage of 22 V,
maximum power point voltage of 17.5, short-circuit current of 545 A.
Configured 220/12 = 18pcs connected in series. Each series power is 18 × 85 =
1530Wp. Each series in accordance with the full power operation of 3.2 hours,
each providing 3.2 × 1530 = 4896 KWH electricity.
Need solar parallel: the daily consumption / (n = array electricity × efficiency)
At: 200 / (4.9 * 0.85) = 48 Unit: 0.85 controller for solar and other conductors,
such as the efficiency losses.
The total need to configure 48 × 18 = 864pcs 85 Wp solar panel
THE DESIGNING OF THE PV GRID-OFF
SYSTEM
• 3. Solar controller configuration
According to the trade unions and arrays: configuration 9pcs SD22100 solar
controller. Each four-way controller solar arrays.
• 4. Inverter configuration
Because users do not have to provide the power size of the load, in
accordance with the working day to 10 hours to estimate, about 30 KW.
Consider cushion and load activated impact of the proposed configuration
SN22050KS power inverter.
Meanwhile, in order to protect key equipment, such as radar and work
normally. Recommends that users load individually configured as the key low-
power inverter power, the inverter and battery SN22050KS common DC bus
power, the specific size can be agreed with the users. The low-power inverter
can be purchased as spared machine.
GRID-CONNECTED PV SYSTEM
RENEWABLE ENERGY GRID-CONNECTED POWER
GENERATING APPLICATIONS
GRID-CONNECTED PV INVERTER
INTRODUCTION
NEWEST DEVELOPED 3K、5K、6K、30K、50K,100K,500K GRID-CONNECTED INVERTER
THE COMPARATIVE ADVANTAGES AND DISADVANTAGES OF
THE STRUCTURE AND TOPOLOGY OF THE COMMON GRID-
CONNECTED INVERTER
•direct inverter system
• Low-frequency
transformer
isolation system
THE COMPARATIVE ADVANTAGES AND
DISADVANTAGES OF THE STRUCTURE AND
TOPOLOGY OF THE COMMON GRID-CONNECTED
INVERTER
• the high-frequency
isolation system
• Multi- More DC-DC
(MPPT), single inverter
system
• the high-frequency
non- isolation system
THE ADVANTAGES AND DISADVANTAGES OF
DIRECT INVERTER SYSTEM
Advantages:
Eliminates cumbersome Frequency Transformer: high efficiency (96 %), light weight,
simple structure.
Disadvantages:
(1) solar panels and electrical power grids not isolation, solar panels have bipolar
voltage power grids, adverse safety.
(2) DC type solar panel’s voltage is more than 350 V. This solar components, and even
the entire system of higher insulation requirements prone to leakage phenomenon.
THE ADVANTAGES AND DISADVANTAGES OF THE LOWE
FREQUENCY TRANSFORMER ISOLATION SYSTEM
Advantages:
Using the frequency transformer to change the voltage and isolate the electricity, it
has the following advantages: simple structure, high reliability, impact resistance,
and good safety performance, MPPT DC voltage 200 V rating in the general-750V.
Disadvantages:
(1) relatively low system efficiency.
(2) heavy
THE ADVANTAGES AND DISADVANTAGES OF HIGH-
FREQUENCY ISOLATION SYSTEM
Advantages:
Having the advantage of electrical isolation as well as light weight, system efficiency 93%.
Disadvantages:
(1) As isolated DC / AC / DC power hierarchy generally smaller, so this topological
structure concentrated in the following 5 KW;
(2) high-frequency DC / AC / DC the work of a high frequency, usually dozens KHz, or
higher, it is more difficult for EMC system design;
(3) the impact of poor system.
THE ADVANTAGES AND DISADVANTAGES OF
THE HIGH-FREQUENCY ISOLATION SYSTEM
Advantages:
Same as the first topology structure, eliminating cumbersome frequency transformer, we can bring the
following advantages: high efficiency, light weight. At the same time joined the BOOST circuit for DC /
DC input voltage DC upgrade, solar array DC input voltage range can be very wide (70 V-750V).
Disadvantages:
(1) Similarly, the solar panels and electrical power grids not isolation, solar panels have bipolar voltage
power grids.
(2) The use of high frequency DC / DC, EMC become even more difficult.
(3) Lower reliability.
MULTI- MORE DC-DC (MPPT),
SINGLE INVERTER SYSTEM
Advantages:
• Same as the advantage of the high-frequency isolation system
• Due to a number of DC-DC circuit for a number of different tilt array of
access, that is, 1 ~ n arrays can have different MPPT voltage, very suitable
for photovoltaic building.
Disadvantages:
• Not with the high-frequency isolation system
USING THE LOW FREQUENCY
TRANSFORMER HIGH POWER THREE-CHASE
HIGH POWER GRID-CONNECTED INVERTER
SYSTEM
Using the low frequency transformer High power three-chase
High Power grid-connected Inverter system 10-500KW
MULTI-LEVEL TRANSFORMATION OF THE
HIGH POWER THREE-PHASE GRID-
CONNECTED INVERTER SYSTEM
THE ADVANTAGES AND DISADVANTAGES OF
SINGLE MACHINE CONNECTING TO THE GRID
Advantages:
• Easy centralized control
• Relatively low cost
• Easy electromagnetic Compatibility
• The better ability of the anti-island effect
Disadvantages:
• Low reliability, high cost of redundancy to achieve
• As all components of PV series-parallel, the
relatively low efficiency of power generation
• Reduce the relative safety of
THE WAY OF DISTRIBUTION OF POWER,
MULTI-BRANCH GRID-CONNECTED INVERTER
THE CHARACTERISTICS OF WAY DISTRIBUTION OF
POWER, MULTI-BRANCH GRID-CONNECTED
INVERTER
• Each Parallel unit is made up by the dozens of 1.5 KW,
2KW, 2.5KW, 3KW PV Grid-connected inverters
parallel. Multiple independent inverter use common
DC bus and 220 V AC bus, and then by an
independent step-up transformer (220 V/10KV) to the
high-voltage power transmission grid.
• The program is suitable for application in different
photovoltaic arrays tilted surface, or a variety of
models of different voltage photovoltaic arrays and
networks. Photovoltaic arrays and network inverter
can have different specifications.
• All the inverter can communicate, remote monitoring
and centralized management through CAN bus or
RS485 bus or Ethernet connected to the network, and
upper control of the PC.
THE SINGLE-PHASE GRID-CONNECTED INVERTER BY,
LOW-FREQUENCY TRANSFORMER ISOLATION
THE SINGLE-PHASE GRID-CONNECTED INVERTER BY DC
BOOST, HIGH-FREQUENCY TRANSFORMER ISOLATION
THE ADVANTAGES AND DISADVANTAGES’
DISTRIBUTION OF POWER, MULTI-BRANCH GRID-
CONNECTED INVERTER
• Advantages:
• Each array independent of each other, and easy to maintain;
• Higher reliability of the whole system;
• Installation flexibility, adaptability good;
• Better safety performance;
• Higher utilization of photovoltaic array
• Disadvantages:
• Relatively high cost
• Can be difficult to achieve electromagnetic compatibility
• Require careful design and verification of the ability of anti-island
effect
THE WAY OF THE GRID-CONNECTED
MULTI-INVERTER PARALLEL
THE CHARACTERISTICS OF GRID-
CONNECTED MULTI-INVERTER PARALLEL
• The program calls for installing photovoltaic arrays in the same
tilted surface, and requires each sub-array has the same power,
voltage and same serial and parallel working model. Multi-inverters
operate Parallel connection.
• Under the control of the group controllers, inverter "operation
tuning ”, not running when not needed, significantly extend the
service life of the inverter. N + X can be realized redundancy.
• Group controllers provide friendly interface. Users can get the
operating parameters, generating capacity, fault enquiries,
parameter settings and so on successfully through the LCD screen
and key directly.
THE ADVANTAGES AND DISADVANTAGES
OF PARALLEL GRID-CONNECTED MULTI-
INVERTER
• Advantages:
• The whole system reliability;
• Installation of a relatively flexible,
• Applicability good;
• Better safety performance;
• High utilization of photovoltaic arrays;
• Algorithm flexible, centralized control;
• Disadvantages:
• Relatively high cost;
• Electromagnetic Compatibility difficult to achieve;
• Require careful design and verification of the ability of anti-island effect
SG SERIES PV GRID-CONNECTED
INVERTER
*Grid-connected PV system includes the PV modules, Grid-connected
inverter and network measurement devices and distribution system.
*Solar cells can generate DC power electricity
*The power is changed to the same- phase, sine wave current through the
PV Grid-connected inverter directly and enters into the power grids.
EXISTING PRODUCT MODELS AND
SPECIFICATIONS
• SG1K5TL 、SG2K5TL (Non-isolated)
• SG3K、SG5K、SG6K
• SG10K3、SG20K3、SG30K3、SG50K3、SG100K3
• SG200K3、SG500K3
SG PRODUCTS CHARACTERISTICS
• using U.S.A. TI Company’s 32 DSP microprocessor control
• using the fifth generation Intelligent Power Module from Mitsubishi.
• maximum power tracking technology (MPPT)
• night zero power technology (single-phase)
• perfect protection (island effect, over-current, over-temperature,
etc.)
• stainless steel shell, all enclosed installation (SG3K,SG5K,SG6K)
• monitoring capabilities improved, through RS485, Ethernet, and
other means of communication
SG SERIES PV GRID-CONNECTED INVERTER
MONITORING SOFTWARE INTERFACE
SG SERIES PV GRID-CONNECTED
INVERTER PRODUCTS PICTURES
SG1.5KTL PV grid-connected inverter SG3K PV grid-connected inverter SG5k,6K indoors type
PV grid-connected inverter
SG5k,6K outdoors type
PV grid-connected inverter
SG30K3,SG50K3 three-chase
PV grid-connected inverter
100KW three-chase
PV grid-connected inverter
SG500K large-scale
PV grid-connected inverter
THE CONTRAST TEST BED FOR THE GRID-CONNECTED INVERTER
BETWEEN JAPAN'S MITSUBISHI、GERMANY’S SMA、SKY RESOURCE'S
CASES
3kw Grid-connected Solar PV
system for Model
100KW Grid-connected Roof Solar PV system
12KW GRID-CONNECTED SOLAR PV
SYSTEM
DESIGN FOR THE GRID-CONNECTED
SOLAR POWER SYSTEM
• The designing of PV Grid-connected system is very random, can be
big, also be small.
• Guangdong region: 1 KWP photovoltaic arrays (conditions:
abundant sunshine)
Daily 3.2 ~ 3.5 KWH of electricity;
• And PV Grid-connect devices and photovoltaic arrays inverter
Matching 1:1
CONCLUSION
• PV Grid-connected system will be an
important trend on the solar photovoltaic
application.
• PV Grid-connected system can be used to
achieve a variety of topology, and many
technical issues need to be carefully examined
and discussed.
• The localization of equipment is required to
be done in advanced, which must abide by the
relevant national and international standards.
Thanks

More Related Content

Similar to Solar Power.ppt

Baykee SR series solar inverter with AVR Function
Baykee SR series solar inverter  with AVR FunctionBaykee SR series solar inverter  with AVR Function
Baykee SR series solar inverter with AVR Functionwendy chen
 
Balance of system
Balance of system Balance of system
Balance of system kinjal2112
 
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.ppt
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.pptPV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.ppt
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.pptArpoMukherjee1
 
PWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PWM SOLAR CHARGE CONTROLLER ARDUINO NANOPWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PWM SOLAR CHARGE CONTROLLER ARDUINO NANOSaikat Bhandari
 
NEPQA and Solar Testing in RETS, Nepal
NEPQA and Solar Testing in RETS, NepalNEPQA and Solar Testing in RETS, Nepal
NEPQA and Solar Testing in RETS, NepalSujita Thakali
 
KRYPTON CONTROL AND SOLUTIONS
KRYPTON CONTROL AND SOLUTIONSKRYPTON CONTROL AND SOLUTIONS
KRYPTON CONTROL AND SOLUTIONSRobins Thekkedath
 
Solar charge controller
Solar charge controllerSolar charge controller
Solar charge controllerSiya Agarwal
 
Solar Charged Stand Alone Inverter
Solar Charged Stand Alone InverterSolar Charged Stand Alone Inverter
Solar Charged Stand Alone InverterIJERA Editor
 
Sunways solar system
Sunways solar systemSunways solar system
Sunways solar systemWalter Jin
 
Solar Powered Home Back Up Power
Solar Powered Home Back Up PowerSolar Powered Home Back Up Power
Solar Powered Home Back Up PowerSolar Electrics
 
Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulatorJestem Zhou
 
Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulatorJoeChueng
 
4_5958416552171670667.ppt
4_5958416552171670667.ppt4_5958416552171670667.ppt
4_5958416552171670667.ppthussenbelew
 
Design off grid solar PV system
Design off grid solar PV systemDesign off grid solar PV system
Design off grid solar PV systemRajesh Pindoriya
 
Mobile cellphone battery charging circuit with explanation
Mobile cellphone battery charging circuit with explanationMobile cellphone battery charging circuit with explanation
Mobile cellphone battery charging circuit with explanationelprocus
 

Similar to Solar Power.ppt (20)

Baykee SR series solar inverter with AVR Function
Baykee SR series solar inverter  with AVR FunctionBaykee SR series solar inverter  with AVR Function
Baykee SR series solar inverter with AVR Function
 
Charge controller
Charge controllerCharge controller
Charge controller
 
Balance of system
Balance of system Balance of system
Balance of system
 
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.ppt
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.pptPV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.ppt
PV SYSTEMS, COMPONENTS DEVICES AND APPLICATIONS.ppt
 
PWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PWM SOLAR CHARGE CONTROLLER ARDUINO NANOPWM SOLAR CHARGE CONTROLLER ARDUINO NANO
PWM SOLAR CHARGE CONTROLLER ARDUINO NANO
 
Solar ppt
Solar pptSolar ppt
Solar ppt
 
NEPQA and Solar Testing in RETS, Nepal
NEPQA and Solar Testing in RETS, NepalNEPQA and Solar Testing in RETS, Nepal
NEPQA and Solar Testing in RETS, Nepal
 
KRYPTON CONTROL AND SOLUTIONS
KRYPTON CONTROL AND SOLUTIONSKRYPTON CONTROL AND SOLUTIONS
KRYPTON CONTROL AND SOLUTIONS
 
Solar charge controller
Solar charge controllerSolar charge controller
Solar charge controller
 
Solar Charged Stand Alone Inverter
Solar Charged Stand Alone InverterSolar Charged Stand Alone Inverter
Solar Charged Stand Alone Inverter
 
Sunny boy storage 2.5
Sunny boy storage 2.5Sunny boy storage 2.5
Sunny boy storage 2.5
 
Solar tracking
Solar trackingSolar tracking
Solar tracking
 
Sunways solar system
Sunways solar systemSunways solar system
Sunways solar system
 
2016 must power limited company profile (www.must-solar.com)
2016 must power limited company profile (www.must-solar.com)2016 must power limited company profile (www.must-solar.com)
2016 must power limited company profile (www.must-solar.com)
 
Solar Powered Home Back Up Power
Solar Powered Home Back Up PowerSolar Powered Home Back Up Power
Solar Powered Home Back Up Power
 
Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulator
 
Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulator
 
4_5958416552171670667.ppt
4_5958416552171670667.ppt4_5958416552171670667.ppt
4_5958416552171670667.ppt
 
Design off grid solar PV system
Design off grid solar PV systemDesign off grid solar PV system
Design off grid solar PV system
 
Mobile cellphone battery charging circuit with explanation
Mobile cellphone battery charging circuit with explanationMobile cellphone battery charging circuit with explanation
Mobile cellphone battery charging circuit with explanation
 

Recently uploaded

How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxmanuelaromero2013
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformChameera Dedduwage
 
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxContemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxRoyAbrique
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Sapana Sha
 
Science 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsScience 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsKarinaGenton
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introductionMaksud Ahmed
 
Class 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfClass 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfakmcokerachita
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTiammrhaywood
 
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfEnzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfSumit Tiwari
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptxVS Mahajan Coaching Centre
 
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...M56BOOKSTORE PRODUCT/SERVICE
 
Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon AUnboundStockton
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docxPoojaSen20
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxheathfieldcps1
 
Solving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxSolving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxOH TEIK BIN
 

Recently uploaded (20)

Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptx
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy Reform
 
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptxContemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
Contemporary philippine arts from the regions_PPT_Module_12 [Autosaved] (1).pptx
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
 
Science 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsScience 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its Characteristics
 
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Tilak Nagar Delhi reach out to us at 🔝9953056974🔝
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
Class 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdfClass 11 Legal Studies Ch-1 Concept of State .pdf
Class 11 Legal Studies Ch-1 Concept of State .pdf
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
 
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdfEnzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
Enzyme, Pharmaceutical Aids, Miscellaneous Last Part of Chapter no 5th.pdf
 
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions  for the students and aspirants of Chemistry12th.pptxOrganic Name Reactions  for the students and aspirants of Chemistry12th.pptx
Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
 
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
 
Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon A
 
9953330565 Low Rate Call Girls In Rohini Delhi NCR
9953330565 Low Rate Call Girls In Rohini  Delhi NCR9953330565 Low Rate Call Girls In Rohini  Delhi NCR
9953330565 Low Rate Call Girls In Rohini Delhi NCR
 
Staff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSDStaff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSD
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docx
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptx
 
Solving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxSolving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptx
 

Solar Power.ppt

  • 2. CLARIFICATION OF THE SOLAR ENERGY POWER GENERATING Following two type of the solar energy power generating • Grid-off solar energy power generating Main used in the area where is no electricity supply or the telecommunication station which is faraway from the electricity net or the wireless places. Key components:solar panel、battery、intelligent controller、 inverter 、electricity distribution and anti-lighting system. (electricity distribution is close to the active load). Advantages:offer the independent electricity net which will not restricted by the local public electricity net. Disadvantages:much waste of the energy resources or can controller the use of the solar energy resources. the electricity use is high restricted by the weather condition, the low efficiency of use and high investment, a little low system life span (especially say the batter’s life span).
  • 3. • Grid-On PV System Main use in the place where the city electricity distribution net. It is the lead direction of New energy from home and all over the world. Key components: solar panel、grid-on inverter、 electricity distribution and anti-lighting system (much simple ). Advantages:high efficient use of the system,long life span;the investment cost is some lower;the use of the electricity will not restricted by the system itself and the weather condition influence. Disadvantages:the return of the electricity powered by solar will be restricted by the local public electricity net.
  • 4. THE INDEPENDENT GRID-OFF SOLAR ENERGY POWER GENERATING SYSTEM DETAILED INTRODUCTION
  • 5. SOLAR PANEL/MODULE Solar Panel is a generating equipment which can transfer the solar light energy to the DC electricity energy. It is made as a single panel when use according to the different requirements on the power output and its voltage. It also can be used as several solar panel connected in series (which is to meet the demands on voltage) and connected in parallel (which is to meet the demands on current). this way can make as the panel/modules arrays to supply much higher electricity demands. the solar panel/modules has many advantages such as high power efficiency on area,long life span, and high reliability,during the use period, the loss of the output power is less than 20%.
  • 6. THE FEATURES OF VOLT- AMPERE FOR PV SOLAR PANEL Generally speaking,the solar panel electricity generating is increased in percentage with the intensity of the sunlight. With the surface temperature increased of the solar panel slightly decreased. The so-called general of the solar panels that power is in the sunlight intensity of 1000 W/M2, components, surface temperature is 20 ℃, Imax * Umax value.
  • 7. PHOTOVOLTAIC MODULE INSTALLATION ANGLE Photovoltaic module installed inclination should be guaranteed to receive the maximum sunlight exposure, in normal circumstances components and the horizontal direction for the local latitude ± 5 °to 10 °. That is, when the reduction in the summer, when the increase in the winter. If a fixed angle brackets, the use of local latitude tilt angle. For example, the city of Shantou to 23.42 °latitude.
  • 8. BATTERY DISCHARGE CURVES • 10 hour rate (0.1 CA), 5 hour rate (0.17 CA), 3 hours rate (0.25 CA) discharge termination voltage: 10.8 V /set; 1 hour rate (0.55 CA) discharge termination voltage: 10.5 V / set. • Termination of battery discharge voltage minimum not more than 9.6 V / only to ensure that the battery will not over-discharge.
  • 9. THE RELATIONSHIP BETWEEN BATTERY LIFE AND TEMPERATURE CURVE In the environmental temperature 15 to 25 ℃ and the proper use of circumstances, the use of rechargeable batteries floating design life of 5 to 8 years. Environmental temperature on the battery life is greatly affected when the ambient temperature every 10 ℃ increased battery life of about 50 % reduction. Therefore, to extend battery life, the battery should be maintained as far as possible in 15 to 25 ℃.
  • 10. BLOCK DIAGRAM OF THE SOLAR CONTROLLER
  • 11. SMALL PV POWER INTELLIGENT CONTROLLER Characteristics: 1. Solar protection reverse: solar + and - to the anti-polarity, after correct, it can continue to use. 2. Battery Open circuit protection: If the battery breaks, and batteries can be rechargeable normally, the controller will be limited at both ends of load voltage, to ensure that the load is not injury, if at night or solar battery not be chartered, the controller due to its own access to electricity, will not have any action; 3. Overcharge protection: protection of charge voltage higher than the voltage, automatic shutdown of rechargeable batteries. When the voltage then swap to maintain voltage, battery enter Float state, when less than restoring voltage Float closed, are sufficient to enter the state. Have sufficient voltage protection and restoration of both temperature compensation voltage Float; 4. When the battery voltage is lower than the protection of voltage, the controller automatically shut down output in order to protect the battery from damage; 5. Over voltage protection: When high voltage, output shut down automatically to protect against electrical damage. A charge, the release of over-voltage protection are delayed action to prevent the disoperation. 6. With temperature compensation function 7. Variety of control options functions: general charge and discharge mode, light is turned off mode, the opening of the shutdown mode Small PV power Intelligent Controller 5A 、10A
  • 12. MID-POWER PHOTOVOLTAIC CONTROLLER 1.LCD display: LCD shows Users Display System important information such as the battery voltage, the charge Current and discharge Current, the operation mode and the system parameters, system status by the digital and English 2. Automatic / manual / night features: Programmable Load Control Ways to automatically or manually. Manual, manual load Open or closed. At this time, the evening function invalid. When choosing night function, the controller closed in the daytime load detection evening, Automatically after a period of time delayed opening load, regular time, it has been Dynamic load shut down. Regular time and delay time based programmable Determined; 3. Protection features: over-charged, over-discharged, output overload, over -Pressure, high temperature protection; 4. Float voltage with the temperature compensation function; 5 fast charging functions: the battery voltage falls below a certain value, rapid Start charging automatically, the controller will increase battery power Pressure, when the battery voltage achieve the desired value, started fast charging When Countdown procedures, regular time, with rapid charging state. Therefore, Full use of solar energy. 6. Automatic identification functions: the first power, in accordance with electrical storage controller Pool automatic identification terminal voltage is 12 V or 24 V system; 7. Mode: normal charge-discharge mode, light is turned off mode, - The opening of the shutdown mode. Mid-Power Photovoltaic Controller 20A、30A
  • 13. HIGH-POWER PHOTOVOLTAIC CONTROLLER High-Power Photovoltaic Controller 50A-100A Standard 4U Cabinets High-Power Photovoltaic Controller 150A-200A Standard 6U Cabinets
  • 14. HIGH-POWER PHOTOVOLTAIC CONTROLLER Waterproof Outdoor Mount 250A-400A 1200 Standard Cabinets 100A-200A
  • 15. THE CHARACTERISTICS OF THE HIGH-POWER PHOTOVOLTAIC CONTROLLER (1) • DSP chip microcomputer control, the charge and discharge parameters, temperature compensation coefficient programmable arbitrary , can adapt to the special requirements of different occasions. • LCD dot matrix modules that operate in both English and Chinese menu, users can switch choice; • Various LED indicator to display photovoltaic charge state and load-off state; • 9 touch buttons; • Control circuit totally isolated from the main circuit, high anti-jamming capability; • 1-18 Road solar input control; • Real-time display battery voltage, load current, the total current photovoltaic, Each PV current, battery temperature, the total number of hours photovoltaic power generation, the cumulative load of electricity, and some like several dozen parameters;
  • 16. THE CHARACTERISTICS OF THE HIGH-POWER PHOTOVOLTAIC CONTROLLER (2) • the historical data and Statistics show: the number of charge cycles, the number of discharges, the number of overload, short-circuit number; Programmable voltage generator start-up and shutdown, secondary load-off voltage, wind generator unloading and recovery voltage, street photosensitive parameters such as voltage switch; • Users can set up a rechargeable battery discharge protection and the protection of the load-off state; • With the Second ability to control, that is the main load and secondary load in different battery voltage electrical point of control; • Various charge pressure of a "backlash" control functions, to prevent oscillation switch into the state; • Protection features: with a rechargeable battery, a discharge, output overload, short-circuit, surge, solar or battery against a short circuit to the anti-battery at night and a series of anti-anti-sufficient warning and protection; • RS232/485 interfaces can be allocated to facilitate long-distance remote, remote control; PC control software can be measured real-time data, alarm information, change control parameters, read the daily 30 days maximum battery voltage, battery voltage minimum daily PV and the total volume of electricity consumed by the daily load accumulated historical data; • Parameter settings and the ability to password-protect users may modify password;
  • 17. THE CHARACTERISTICS OF THE HIGH-POWER PHOTOVOLTAIC CONTROLLER (3) • Warning: over-voltage, under-voltage, overload, short-circuit protection, such as alarm; • Multi-channel output report to the police or passive control contact: a rechargeable battery, a battery discharge, Diesel boot control, load disconnect, controller fault; other user-selectable backup alarm contact, such as flood alarm; • Work step by step-ladder pattern of limited mode, PWM mode, the opening of the off-model-turned-down mode, the clock control mode, the light is turned off early- model, which is the model for the first two occasions common load, After four model load occasions against the lights, all the length and timing clock delay can be set up; • Users can also set up parameters including: are charging pressure, Float voltage, voltage absorption launched voltage regulator dynamic coefficient of static coefficient Regulators are filling state time and state absorption time. • Do not brown-out real-time clock function, display and set the clock; • Lightning: According to system requirements, install different levels of mine devices; • A temperature compensation function; • Portfolio ingenious: alone, but also complementary components scenery, inverter control integration models
  • 18. THE CHARACTERISTICS OF THE INVERTER ★High reliability for new energy generation power plants are often installed in the mountain and pastoral areas, border, islands, and other traffic inconvenience, if there are large temperature difference between day and night, high-altitude and thin air caused by heat, insulation, as well as facing long transport , once a power failure, repair, the more difficult and therefore the reliability of the power supply to more stringent requirements. ★ High efficiency, the current generation of new energy sources, high cost per unit of electricity, the solar panels is expensive, improving the efficiency of inverter power than improving the efficiency of solar panels more efficient and more economical. ★ Specifically for high altitude, cold zone designed to be at an altitude of 6,000 m and -40 ℃ use of ambient temperature (Note: the need for the use of descending). ★ With the discharge of the battery protection, photovoltaic power plants, wind power is often used for the power station on the battery charge controller, real-time management of discharge, the battery will be over- discharge protection with its own power inverter power supply devices to achieve, not only simplify circuit, reduce costs, but also can avoid the conventional DC motor controller-off arising from the widening arc, thus enhancing the reliability of the system.
  • 19. BLOCK DIAGRAM OF THE INVERTER
  • 20. ON THE LOAD CONFIGURATION • Equipment (or other electrical appliances used) on the plate are generally rated current, voltage data, they are multiplied together to receive VA value corresponding power. Users must use carefully inspect the load power in order to avoid overload. With the general operation of electrical appliances in the state, especially in the standby power than the actual state of the mark on some low power users to be used in the use of electrical appliances and of the nominal power, is starting at the same time consider the impact of current, best left 30 % of the power cushion to ensure reliable power supply; • The load should be considered motor-5 ~ 7 times the cushion to impact current.
  • 21. INVERTER POWER PROTECTION protection instruction remarks Output Over- load protection Power load more than 150%, 10 seconds after the shutdown output delay Need to be reset shutdown Short circuit protection If the output short circuit, inverter power will be shut down automatically To protect against the importation Input DC voltage inverter to the anti-polarity, the inverter will be automatically protected Automatically reset, that is, after the failure to eliminate the output will automatically resume Under-voltage Input DC voltage is lower than the under voltage point, inverter power will be shut down automatically Over voltage Input DC voltage is higher than the pressure point, inverter power will be shut down automatically Over heating protection Inverter Power Supply chassis temperature over 75 ℃, the output will be shut down automatically
  • 22. THE DISCHARGED PROTECTION AND RECOVERY • Protection of the over-discharged, the battery voltage required to return to work at 226 V or above can start again. Backlash is set up in order to prevent voltage under voltage system in the near oscillations, as shown in Figure 6.1. • Power attention when booting the first time if the battery voltage is in the release point and resume work between power will be in the state and show under voltage shutdown. • Over-discharged protection value and the restoration of working voltage values for the default settings (subject to user requirements set), general without adjustment. If and where adjustments, in the PC board (SNMC) found on the potential for VR2 (Figure 7.3 Position 6), such as lowering the release point, then clockwise adjustment; such as raising the release point, the anti-clockwise adjustment. Potentiometer adjustment semi-circle, the corresponding change in value of the release point about 7 V, for reference purposes only. Picture 6.1
  • 23. THE MAINTAINABILITY OF PHOTOVOLTAIC POWER SYSTEM’S COMPONENTS 1 Some products photovoltaic power system components can be repaired after used again, known as maintenance parts, but some parts missing validity beyond repair or restoration costs are too high, these components as a non-repair components, the following table lists the photovoltaic power supply Attributes of components in the system. Can be repaired non-repair Inverter Solar panel Controller Maintains free lead acid battery PV water Pump DC lamps Wind turbine Arrester, fuses, wires … … … …
  • 24. THE MAINTAINABILITY OF PHOTOVOLTAIC POWER SYSTEM’S COMPONENTS Actually in photovoltaic power system , some components can be maintained but some can not be. Such as solar panels, maintenance-free batteries, they are difficult to repair after the failure, which is called as the non-maintenance components, which are directly dealt with a narrow reliability index, the main reliability, failure rate, the average life expectancy of three indicators, reliability, R (t) refers to products (or parts) under the conditions set forth in that time to complete the function of the probability of failure rate λ (t) refers to the moment t work has not yet Failure products, in the moment unit time in the probability of failure; average life expectancy refers to the use of products from the beginning until failure occurred experienced by time. The controller, inverter power supply can be maintained, such as products or components, and its main indicators reliability, failure rate and the average time between failures (MTBF) and mean time to repair faults (MTTR). The components can be maintained and by the maintenance of the components of PV systems, in general, should be understood as products can be maintained.
  • 25. THE DESIGNING OF THE PV GRID-OFF SYSTEM CASE: • Requirements: computers, lighting, radar (emotional) of load, time uncertain, the daily power consumption about 200 KWH, batteries to power for three days cloudy. 1. Battery configuration (in accordance with the allocation of work for three rainy days): Battery groups voltage: 220 V Capacity needs: (daily needed electricity × rainy days × 1000) / (battery voltage ×discharge capacity) Discharge capacity: In the process of battery usage, the battery capacity released by the percentage of its rated capacity, known as the discharge capacity. Discharge capacity to the protection of small batteries, the election is generally recommended 0.5 (200 × 3 × 1000) / (220 * 0.5 * 0.9) = 5754 AH choose 2 V1000AH battery of a total of five groups of 110pcs, a total of 550pcs.
  • 26. THE DESIGNING OF THE PV GRID-OFF SYSTEM • 2. Solar array configurations: Need to configure the maximum power to maintain voltage in the vicinity of 220V , Selection of 85 Wp (or other specifications): open-circuit voltage of 22 V, maximum power point voltage of 17.5, short-circuit current of 545 A. Configured 220/12 = 18pcs connected in series. Each series power is 18 × 85 = 1530Wp. Each series in accordance with the full power operation of 3.2 hours, each providing 3.2 × 1530 = 4896 KWH electricity. Need solar parallel: the daily consumption / (n = array electricity × efficiency) At: 200 / (4.9 * 0.85) = 48 Unit: 0.85 controller for solar and other conductors, such as the efficiency losses. The total need to configure 48 × 18 = 864pcs 85 Wp solar panel
  • 27. THE DESIGNING OF THE PV GRID-OFF SYSTEM • 3. Solar controller configuration According to the trade unions and arrays: configuration 9pcs SD22100 solar controller. Each four-way controller solar arrays. • 4. Inverter configuration Because users do not have to provide the power size of the load, in accordance with the working day to 10 hours to estimate, about 30 KW. Consider cushion and load activated impact of the proposed configuration SN22050KS power inverter. Meanwhile, in order to protect key equipment, such as radar and work normally. Recommends that users load individually configured as the key low- power inverter power, the inverter and battery SN22050KS common DC bus power, the specific size can be agreed with the users. The low-power inverter can be purchased as spared machine.
  • 28. GRID-CONNECTED PV SYSTEM RENEWABLE ENERGY GRID-CONNECTED POWER GENERATING APPLICATIONS
  • 29. GRID-CONNECTED PV INVERTER INTRODUCTION NEWEST DEVELOPED 3K、5K、6K、30K、50K,100K,500K GRID-CONNECTED INVERTER
  • 30. THE COMPARATIVE ADVANTAGES AND DISADVANTAGES OF THE STRUCTURE AND TOPOLOGY OF THE COMMON GRID- CONNECTED INVERTER •direct inverter system • Low-frequency transformer isolation system
  • 31. THE COMPARATIVE ADVANTAGES AND DISADVANTAGES OF THE STRUCTURE AND TOPOLOGY OF THE COMMON GRID-CONNECTED INVERTER • the high-frequency isolation system • Multi- More DC-DC (MPPT), single inverter system • the high-frequency non- isolation system
  • 32. THE ADVANTAGES AND DISADVANTAGES OF DIRECT INVERTER SYSTEM Advantages: Eliminates cumbersome Frequency Transformer: high efficiency (96 %), light weight, simple structure. Disadvantages: (1) solar panels and electrical power grids not isolation, solar panels have bipolar voltage power grids, adverse safety. (2) DC type solar panel’s voltage is more than 350 V. This solar components, and even the entire system of higher insulation requirements prone to leakage phenomenon.
  • 33. THE ADVANTAGES AND DISADVANTAGES OF THE LOWE FREQUENCY TRANSFORMER ISOLATION SYSTEM Advantages: Using the frequency transformer to change the voltage and isolate the electricity, it has the following advantages: simple structure, high reliability, impact resistance, and good safety performance, MPPT DC voltage 200 V rating in the general-750V. Disadvantages: (1) relatively low system efficiency. (2) heavy
  • 34. THE ADVANTAGES AND DISADVANTAGES OF HIGH- FREQUENCY ISOLATION SYSTEM Advantages: Having the advantage of electrical isolation as well as light weight, system efficiency 93%. Disadvantages: (1) As isolated DC / AC / DC power hierarchy generally smaller, so this topological structure concentrated in the following 5 KW; (2) high-frequency DC / AC / DC the work of a high frequency, usually dozens KHz, or higher, it is more difficult for EMC system design; (3) the impact of poor system.
  • 35. THE ADVANTAGES AND DISADVANTAGES OF THE HIGH-FREQUENCY ISOLATION SYSTEM Advantages: Same as the first topology structure, eliminating cumbersome frequency transformer, we can bring the following advantages: high efficiency, light weight. At the same time joined the BOOST circuit for DC / DC input voltage DC upgrade, solar array DC input voltage range can be very wide (70 V-750V). Disadvantages: (1) Similarly, the solar panels and electrical power grids not isolation, solar panels have bipolar voltage power grids. (2) The use of high frequency DC / DC, EMC become even more difficult. (3) Lower reliability.
  • 36. MULTI- MORE DC-DC (MPPT), SINGLE INVERTER SYSTEM Advantages: • Same as the advantage of the high-frequency isolation system • Due to a number of DC-DC circuit for a number of different tilt array of access, that is, 1 ~ n arrays can have different MPPT voltage, very suitable for photovoltaic building. Disadvantages: • Not with the high-frequency isolation system
  • 37. USING THE LOW FREQUENCY TRANSFORMER HIGH POWER THREE-CHASE HIGH POWER GRID-CONNECTED INVERTER SYSTEM Using the low frequency transformer High power three-chase High Power grid-connected Inverter system 10-500KW
  • 38. MULTI-LEVEL TRANSFORMATION OF THE HIGH POWER THREE-PHASE GRID- CONNECTED INVERTER SYSTEM
  • 39. THE ADVANTAGES AND DISADVANTAGES OF SINGLE MACHINE CONNECTING TO THE GRID Advantages: • Easy centralized control • Relatively low cost • Easy electromagnetic Compatibility • The better ability of the anti-island effect Disadvantages: • Low reliability, high cost of redundancy to achieve • As all components of PV series-parallel, the relatively low efficiency of power generation • Reduce the relative safety of
  • 40. THE WAY OF DISTRIBUTION OF POWER, MULTI-BRANCH GRID-CONNECTED INVERTER
  • 41. THE CHARACTERISTICS OF WAY DISTRIBUTION OF POWER, MULTI-BRANCH GRID-CONNECTED INVERTER • Each Parallel unit is made up by the dozens of 1.5 KW, 2KW, 2.5KW, 3KW PV Grid-connected inverters parallel. Multiple independent inverter use common DC bus and 220 V AC bus, and then by an independent step-up transformer (220 V/10KV) to the high-voltage power transmission grid. • The program is suitable for application in different photovoltaic arrays tilted surface, or a variety of models of different voltage photovoltaic arrays and networks. Photovoltaic arrays and network inverter can have different specifications. • All the inverter can communicate, remote monitoring and centralized management through CAN bus or RS485 bus or Ethernet connected to the network, and upper control of the PC.
  • 42. THE SINGLE-PHASE GRID-CONNECTED INVERTER BY, LOW-FREQUENCY TRANSFORMER ISOLATION
  • 43. THE SINGLE-PHASE GRID-CONNECTED INVERTER BY DC BOOST, HIGH-FREQUENCY TRANSFORMER ISOLATION
  • 44. THE ADVANTAGES AND DISADVANTAGES’ DISTRIBUTION OF POWER, MULTI-BRANCH GRID- CONNECTED INVERTER • Advantages: • Each array independent of each other, and easy to maintain; • Higher reliability of the whole system; • Installation flexibility, adaptability good; • Better safety performance; • Higher utilization of photovoltaic array • Disadvantages: • Relatively high cost • Can be difficult to achieve electromagnetic compatibility • Require careful design and verification of the ability of anti-island effect
  • 45. THE WAY OF THE GRID-CONNECTED MULTI-INVERTER PARALLEL
  • 46. THE CHARACTERISTICS OF GRID- CONNECTED MULTI-INVERTER PARALLEL • The program calls for installing photovoltaic arrays in the same tilted surface, and requires each sub-array has the same power, voltage and same serial and parallel working model. Multi-inverters operate Parallel connection. • Under the control of the group controllers, inverter "operation tuning ”, not running when not needed, significantly extend the service life of the inverter. N + X can be realized redundancy. • Group controllers provide friendly interface. Users can get the operating parameters, generating capacity, fault enquiries, parameter settings and so on successfully through the LCD screen and key directly.
  • 47. THE ADVANTAGES AND DISADVANTAGES OF PARALLEL GRID-CONNECTED MULTI- INVERTER • Advantages: • The whole system reliability; • Installation of a relatively flexible, • Applicability good; • Better safety performance; • High utilization of photovoltaic arrays; • Algorithm flexible, centralized control; • Disadvantages: • Relatively high cost; • Electromagnetic Compatibility difficult to achieve; • Require careful design and verification of the ability of anti-island effect
  • 48. SG SERIES PV GRID-CONNECTED INVERTER *Grid-connected PV system includes the PV modules, Grid-connected inverter and network measurement devices and distribution system. *Solar cells can generate DC power electricity *The power is changed to the same- phase, sine wave current through the PV Grid-connected inverter directly and enters into the power grids.
  • 49. EXISTING PRODUCT MODELS AND SPECIFICATIONS • SG1K5TL 、SG2K5TL (Non-isolated) • SG3K、SG5K、SG6K • SG10K3、SG20K3、SG30K3、SG50K3、SG100K3 • SG200K3、SG500K3
  • 50. SG PRODUCTS CHARACTERISTICS • using U.S.A. TI Company’s 32 DSP microprocessor control • using the fifth generation Intelligent Power Module from Mitsubishi. • maximum power tracking technology (MPPT) • night zero power technology (single-phase) • perfect protection (island effect, over-current, over-temperature, etc.) • stainless steel shell, all enclosed installation (SG3K,SG5K,SG6K) • monitoring capabilities improved, through RS485, Ethernet, and other means of communication
  • 51. SG SERIES PV GRID-CONNECTED INVERTER MONITORING SOFTWARE INTERFACE
  • 52. SG SERIES PV GRID-CONNECTED INVERTER PRODUCTS PICTURES SG1.5KTL PV grid-connected inverter SG3K PV grid-connected inverter SG5k,6K indoors type PV grid-connected inverter SG5k,6K outdoors type PV grid-connected inverter SG30K3,SG50K3 three-chase PV grid-connected inverter 100KW three-chase PV grid-connected inverter SG500K large-scale PV grid-connected inverter
  • 53. THE CONTRAST TEST BED FOR THE GRID-CONNECTED INVERTER BETWEEN JAPAN'S MITSUBISHI、GERMANY’S SMA、SKY RESOURCE'S
  • 54. CASES 3kw Grid-connected Solar PV system for Model
  • 55. 100KW Grid-connected Roof Solar PV system
  • 57. DESIGN FOR THE GRID-CONNECTED SOLAR POWER SYSTEM • The designing of PV Grid-connected system is very random, can be big, also be small. • Guangdong region: 1 KWP photovoltaic arrays (conditions: abundant sunshine) Daily 3.2 ~ 3.5 KWH of electricity; • And PV Grid-connect devices and photovoltaic arrays inverter Matching 1:1
  • 58. CONCLUSION • PV Grid-connected system will be an important trend on the solar photovoltaic application. • PV Grid-connected system can be used to achieve a variety of topology, and many technical issues need to be carefully examined and discussed. • The localization of equipment is required to be done in advanced, which must abide by the relevant national and international standards. Thanks