VeriVide standard light source color light boxes are one of the main selling products from Standard International Group (HK) Limited, the British imported, and leading comprehensive quality. Next, a standard Group engineers will VeriVide CAC60 standard light source for color light boxes, for example, a brief description of the use of the process VeriVide Light box
1. VeviVide CAC60 Light Cabinet Instructions
Date: 3
rd
, June, 2016|Author: Qinsun
VeriVide standard light source color light boxes are one of the main selling products from Standard
International Group (HK) Limited, the British imported, and leading comprehensive quality. Next, a
standard Group engineers will VeriVide CAC60 standard light source for color light boxes, for example, a
brief description of the use of the process VeriVide Light box
VeriVide Light box Description:
1. Random power cord to connect the box; plug the other end to a power supply outlet, with power (220V50HZ)
2. Open light boxes on the right side of a red button; this is the main switch, turn off the power on
3. Tap on the ON / OFF button on the color boxes panel, LCD liquid crystal module (with backlight) display powered on, the
light sources and flow displays the name and accumulated operating time
4. Random by D65, UV, F / A, TL84, CWF, U30 keys can automatically switch, can also open a variety of sources (press). In
the case of a single light source, the time display of the corresponding source name and time, in the case of multiple light
sources is activated, the display has started flowing source name and time. CLR key board used as a reset is cleared, in the
case of a single light source is activated below the effective
5. Product will be detected in standard light source for color boxes backplane central location. 90-degree viewing angle to a
light source, 45-degree line of sight is appropriate. Suitable angle can be adjusted according to the measured shape of the
article, to achieve the best results detected.
6. When replacing a new lamp, various light sources (pipe) have to install the appropriate position; the position of the lamp
cannot be reversed. After the replacement of old fluorescent tubes, the original use of time should be cleared (i.e. re-start
times), clear method: Open a good replacement lamp with a screwdriver inserted into the center hole to the CLR, click on the
button (other fluorescent tubes use of time will not be cleared). Note: Do not free to use CLR key, to avoid mistakenly cleared
timing system time.
7. The standard light source for color boxes with a variety of standard light source, all mounted in a fixed position on the light
box, the location cannot be reversed
8. Turn the power off Press ON / OFF button. Unused for long periods Unplug the power off