1. CONTROL
A user friendly control is equipped with an
on/off switch, LED displays for dryer and
compressor operation, and a LED bar
graph display for the pressure dew point.
FULLY AUTOMATIC VALVE
A check valve is designed to proportionally
control the flow of the refrigerant into the
heat exchanger according to the air volume
flow. The R134a and R407c coolants ensure
environmentally friendly operation.
AIR COOLED CONDENSER
Extremely large cooling coils means that
the condenser is able to work effectively
and efficiently even in the most adverse
conditions to cool the saturated compressed
air – for maximum operational safety.
CONSISTENT PRESSURE DEW POINT
The stainless steel 3-in-1 heat exchanger
with integrated separator assures a consistent
pressure dew point under differing ambient
conditions. The low pressure differential ensures
high quality compressed air.
1) Heat exchanger with integrated separator
2) Compact design low corrosion galvanized
steel housing
3) Air cooled condenser (ED 23 - ED 137 only)
4) Control valve for proportional refrigerant
flow into heat exchanger
5) Compressor
Installation instructions
For the standard dryers, the room and/or
ambient temperature may not exceed +49°C
(ED 3 - 17) or +43°C ED 23 - 137), and not
fall below +4.4°C. The refrigerant dryer should
have sufficient free space around it in order
to ensure satisfactory cooling air circulation.
A sufficiently dimensioned drain pipe is
required to take away the condensate.
Design conditions
The max. inlet temperature is +55°C
(ED 3 - ED 17) or +58°C respectively
(ED 23 - ED 137).
Features:
• Dew point bar graph display (ED 3 - ED 40)
and/or LED display (ED 53 - ED 137)
• Timer controlled condensate drain
(except ED 3: type Float)
• Coolant R134a (ED 3 - ED 27)
and R407c (ED 40 - ED 137)
Options:
• Standard bypass line
1
2
34
5
AMBIENT TEMPERATURE
The design feature of the ED 3 - ED 17 series
is the static condenser which allows the
dryer to be air cooled irrespective of variable
ambient temperatures (see conversion factors).
STATIC CONDENSER
A static condenser means the ED 3 - ED 17
series is air cooled working reliably without
any additional fan or energy consumption.
BOGE ED Series:
Refrigerant Dryers
BOGE AIR. THE AIR TO WORK.
2. Refrigerant compressed air dryers ED 3 – ED 137
Flow rate: 0.33 – 13.67 m³/min
Max. operating pressure: 16 bar
* Emitted sound pressure level of 45 dB(A) upwards.
** ED 3 – ED 17 equipped with bi-frequency control.
BOGE
Model
Flow rate* Max.
operating
pressure
Pressure
differential
at full load
Electrical
power
consumption
Electrical
connection
V/Hz**
Compressed
air
connection
Cooling
air
demand
Dimensions
W x D x H
Weight
m3
/min m3
/h bar bar kW 50 Hz m3
/h mm kg
ED 3 0.33 20 16 0.36 0.24 230 R 3
/8
Raumluft 320x 320x382 19
ED 5 0.50 30 16 0.49 0.24 230 R 3
/8
Raumluft 320x 320x382 19
ED 10 1.00 60 16 0.27 0.34 230 R 3
/4
Raumluft 368x 394x568 28
ED 13 1.33 80 16 0.46 0.42 230 R 3
/4
Raumluft 368x 394x568 30
ED 17 1.67 100 16 0.34 0.58 230 R 3
/4
Raumluft 500x 500x568 41
ED 23 2.33 140 16 0.24 0.58 230 R 1 1020 363x 861x601 50
ED 27 2.67 160 16 0.25 0.60 230 R 1 1020 363x 861x601 53
ED 40 4.00 240 16 0.30 0.87 230 R 1 1020 363x 921x601 58
ED 53 5.25 315 16 0.15 1.10 230 R 2 1980 443x 971x761 72
ED 60 6.00 360 16 0.17 1.30 230 R 2 1980 443x 971x761 78
ED 78 7.83 470 16 0.21 1.48 230 R 2 2640 443x 971x761 85
ED 97 9.67 580 16 0.16 1.90 230 R 2 2640 493x1151x811 100
ED 113 11.33 680 16 0.20 2.45 230 R 2 4500 493x1151x811 112
ED 137 13.67 820 16 0.25 2.55 230 R 2 4500 493x1251x811 134
Conversion factors ED 23 – ED 137
Ambient/cooling air temperature °C 25 30 35 40 43
Factor f1
1.00 0.92 0.85 0.78 0.74
Inlet temperature °C 35 40 45 50 55 58
Factor f2
1.00 0.84 0.71 0.63 0.54 0.50
Operating overpressure bar 3 4 5 6 7 8 9 10 11 12 13 14
Factor f3
0.79 0.87 0.92 0.96 1.00 1.03 1.07 1.10 1.13 1.16 1.18 1.21
Sample (for pressure dew point +3°C) and Series ED 3 – ED 17
Volume flow m3
/h 55 Factor
V 55
= = = 74 ED 13
f1
x f2
x f3
1.00 x 0.69 x 1.07
Ambient temperature (f1
) °C 35 = 1.00
Inlet temperature (f2
) °C 45 = 0.69
Operating pressure (f3
) bar 10 = 1.07
Conversion factors
Refrigerant dryers are designed according to DIN ISO 7183 for 7 bar operating pressure, +25°C ambient temperature, and +35°C inlet temperature.
In case of different operating pressures and temperatures the following conversion factors apply.
Conversion factors ED 3 – ED 17
Ambient/cooling air temperature °C 25 30 35 40 45 49
Factor f1
1.00 1.00 1.00 1.00 1.00 1.00 (always 1.00 due to static condenser)
Inlet temperature °C 35 40 45 50 55
Factor f2
1.00 0.82 0.69 0.59 0.50
Operating overpressure bar 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Factor f3
0.70 0.80 0.87 0.92 0.96 1.00 1.03 1.05 1.07 1.08 1.10 1.11 1.12 1.13
313-GB-2-09.2009/T·Technicalchangesanderrorsreserved.