The document contains several engineering drawings related to the installation of a new solar photovoltaic array and battery system at a site. It includes drawings showing plans for new conduit runs and fencing, as well as elevations of the site and details of the proposed photovoltaic array, battery options, and existing equipment.
1. FOREST SERVICE ROAD
SCALE 1/8" - 1'-0"
(E) FENCE
NEW WIND TURBINE AND TOWER
PER PLAN
NEW FENCE
NEW GENERATOR ENCLOSURE
PER STRUCTURAL DWG.
RELOCATED INSPECTION WELL
PER STRUCTURAL DWG.
(E) GENERATOR ENCLOSURE
(E) FENCE
(E) PROPANE TANKS
(E) TOWER
(E) GENERATOR TO BE REMOVED
NEW FENCE
1-1/4" PVC CONDUIT
3 - #4 & 1 - #6
(13) NEW PHOTO VOLTAIC ARRAY
(~52') (~32') (~12')
(~50')
(~50')
(~155')
(NOTE: LENGTHS ARE CONDUIT ONLY)
J-BOX
(TYP 4 PL)
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
(~115')
(~72')(~22')(~42')(~62')
(~115')
SITE CONDUIT PLAN
T1-01.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
CONDUIT PLAN
1-1/4" PVC SCH 40
1
2
3
4
1-1/4" SCH 40 PVC
ARRAY ID
1" PVC SCH 40
(5-PL)
1" PVC SCH 40
(8-PL)
GUTTER
N-7 N-6 N-5 N-4 N-3
S-6 S-5 S-4 S-3
N-2
S-2
N-1
S-1
ACCESS ROAD PER PLAN
(~52') (~32') (~12')(~72')(~22')(~42')
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
2. (E) FENCE
NEW WIND TURBINE AND TOWER
PER PLAN
NEW FENCE
NEW GENERATOR ENCLOSURE
PER STRUCTURAL DWG.
RELOCATED INSPECTION WELL
PER STRUCTURAL DWG.
(E) GENERATOR ENCLOSURE
(E) FENCE
(E) PROPANE TANKS
(E) TOWER
(E)GENERATOR TO BE REMOVED
NEW FENCE
(13) NEW PHOTO VOLTAIC ARRAY
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
GROUNDING CONDUCTOR TO BE #2 SBTC
FOLLOW VZW GROUNDING STANDARDS
FIELD NOTE: PROVIDE 3 ea. PIG TAILS FOR GENERATOR AND ATS
LEGEND
GROUND ROD
EXOTHERMIC WELD
LIGHTNING ROD
TAIL TO BE COILED ABOVE GRADE SCALE 1/8" - 1'-0"
GROUNDING PLAN
T1-02.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
GROUNDING PLAN
TO (E) GROUND RING
ACCESS ROAD PER PLAN
ARRAY ID
N-7 N-6 N-5 N-4 N-3
S-6 S-5 S-4 S-3
N-2
S-2
N-1
S-1
1
1
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
3. (E) FENCE
NEW WIND TURBINE AND TOWER
PER PLAN
NEW FENCE
NEW GENERATOR ENCLOSURE
PER STRUCTURAL DWG.
RELOCATED INSPECTION WELL
PER STRUCTURAL DWG.
(E) GENERATOR ENCLOSURE
(E) FENCE
(E) PROPANE TANKS
(E) TOWER
(E)GENERATOR TO BE REMOVED
NEW FENCE
(13) NEW PHOTO VOLTAIC ARRAY
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
FENCE TO BE 7' - 9 GA CHAIN LINK COMMERCIAL GRADE
3 STRAND BARBED WIRE, PAINTED BLACK
DIMENSIONS ARE REFERENCE ONLY
SCALE 1/8" - 1'-0"
FENCING PLAN
T1-03.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
FENCING PLAN
ACCESS ROAD PER PLAN
162'
40'
48'
ARRAY ID
N-7 N-6 N-5 N-4 N-3
S-6 S-5 S-4 S-3
N-2
S-2
N-1
S-1
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
4. NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
ALL DIMENSIONS MUST BE FIELD VERIFIED
BATTERY OPTIONS
EXISTING EQUIPMENT
T1-04.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
SCALE 1" - 1'-0"
EXISTING EQUIPMENT
(E) BATTERIES
(E) EQUIPMENT
(E) GENERATOR
(E) POWER PLANT
(E) INVERTER PANEL
(E) ATS / ILC
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
5. NEW POWER PLANT
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
ALL DIMENSIONS MUST BE FIELD VERIFIED
BATTERY OPTIONS
DEKA UNIGY II AVR 125-33
OPTION #2
T1-04.02
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
BATTERIES
EXISTING EQUIPMENT
WALL (DEMO)
C D F
(FUTURE)
A B E
(FUTURE)
2'-11
2"
NEW DC FANS
LOCATION TBD
SCALE 1" - 1'-0"
BATTERY PLAN / CONFIGURATION #2
DEKA UNIGY II AVR 125-33 / 1360 AMPERE HOUR
DISCHARGE TO 1.85 VPC
4 STRINGS ( 261.0 kW Hour)
6 STRINGS ( 391.6 kW Hour)
(RELOCATE) INVERTER PANEL
(RELOCATE) ATS / ILC
(N) NEMA 3 LOAD CENTER
AIR INTAKE
LOCATION TBD
HOOD
NEW CABLE LADDER
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
6. NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
ALL DIMENSIONS MUST BE FIELD VERIFIED
BATTERY OPTIONS
GNB 100-G-99
OPTION #1
T1-04.03
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
(N) POWER PLANT
(E) EQUIPMENT
BATTERIES
SCALE 1" - 1'-0"
BATTERY PLAN / CONFIGURATION #1
A B
C
(FUTURE)
(N) DC FANS
LOCATION TBD
GNB 100G99 / 3480 AMPERE HOUR
DISCHARGE TO 1.84 VPC
2 STRINGS ( 334.0 kW Hour)
3 STRINGS ( 501.1 kW Hour)
(RELOCATE) INVERTER PANEL
(RELOCATE) ATS / ILC
(N) NEMA 3 LOAD CENTER
AIR INTAKE
LOCATION TBD
HOOD
(N) CABLE LADDER
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
7. 4410
4415
4420
4425
4430
4435
4440
NEW WIND TURBINE AND TOWER
PER PLAN
FOREST SERVICE ROAD GRADE
(13) NEW PHOTO VOLTAIC ARRAY
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
SCALE 3/32" - 1'-0"
NORTH ELEVATION
T2-01.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
NORTH ELEVATION
(E) PROPANE TANK ENCLOSURE
ELEVATION CONTOURS AT 5'
ELEVATION (FT)
NEW FENCE
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
8. 4410
4415
4420
4425
4430
4435
4440
NEW WIND TURBINE AND TOWER
PER PLAN
FOREST SERVICE ROAD GRADE
(13) NEW PHOTO VOLTAIC ARRAY
NOTE: THIS DRAWING IS A GRAPHICAL REPRESENTATION
NOT A SURVEY
SCALE 3/32" - 1'-0"
WEST ELEVATION
T2-02.00
NTS
JH
DM
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
NORTH ELEVATION
PROPANE ENCLOSURE
TOWER FOOTING BEYOND
ELEVATION (FT)
NEW FENCE
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
9. SIDE ELEVATION
3-POSITION MANUAL ADJUSTMENT
PIER FOOTING SHOWN
FRONT ELEVATION REAR ELEVATION
MANUFACTURED
PV ARRAY
SUPPORT FRAME
UNI-RAC OR EQUIVALENT
PANEL ASSY ONLY ~ # 600
(REF)
10' SNOW LEVEL
(REF)
-A- -A-
SECTION -A-
PHOTO VOLTAIC ARRAY
STRAIGHT ARM MOUNTING
T5-01.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
SIDE ELEVATION
3-POSITION MECHANICAL ADJUSTMENT
SPREAD FOOTING SHOWN
FOUNDATION DETAIL
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615
10. 30 kW
45.8 FLA G
30 kW
45.8 FLA
3 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH 40
PVC CONDUIT
WIND TURBINE
BWC EXCEL -R
XX kW
XX FLA
WT
TURBINE TOWER
G
CELL SITE BUILDING
ATS-01
240/120V
(AUTO TRANSFER
SWITCH)
PANEL BOARD
Note 1
XX KVA
Pri: 3 PH / VAC
Sec: 48 VDC
XX k AIC
RECTIFIER
CONTROLLER
(E) EXCEL TECH
1100 W
INVERTER
(5 EA)
RECTIFIERS
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
DC POWER
PANEL
-48 VDC
DC POWER
PANEL
INVERTED POWER
PANEL
CONTROLLER
BATTERIES
-48 VDC
CONTROLLER
PHOTOVOLTAIC ARRAY
SUN POWER E20 -327
OUTDOOR GENERATOR
OUTDOOR GENERATOR
3 - 3/0 AWG
+1- #2 AWG GND
2" SCH 40
PVC CONDUIT
DC / DC
CONVERTER 24 VDC
DC POWER
PANEL
THIRD PARTY
CONTROLLER
(TYP 13 PL)
3 - 3/0 AWG
+1- #2 AWG GND
2" SCH 40
PVC CONDUIT
8 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH40
PVC CONDUIT
2 - #6 AWG
+1- #10 AWG GND
1" SCH 40
PVC CONDUIT
6 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH40
PVC CONDUIT
(3 EA)
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
J-BOX
2 - 12 AWG
+1- 12 AWG GND
(12 PL)
MICROWAVE
DC FANS
GEN LIGHTING
FUTURE
FUTURE
FUTURE
RADIO
RADIO
FUTURE
INVERTER
2 - 10 AWG
(5 PL)
BLOCK HEATER
OIL HEATER
TIMER
LIGHTS GEN RM
BLOCK HEATER
LIGHTS EQ RM
HVAC
HVAC
FUTURE
FUTURE
FUTURE
FUTURE
30 kW
45.8 FLA G
30 kW
45.8 FLA
3 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH 40
PVC CONDUIT
WIND TURBINE
BWC EXCEL -R
XX kW
XX FLA
WT
TURBINE TOWER
G
CELL SITE BUILDING
ATS-01
240/120V
(AUTO TRANSFER
SWITCH)
PANEL BOARD
Note 1
XX KVA
Pri: 3 PH / VAC
Sec: 48 VDC
XX k AIC
RECTIFIER
CONTROLLER
INVERTER
RECTIFIERS
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
DC POWER
PANEL
-48 VDC
DC POWER
PANEL
INVERTED POWER
PANEL
CONTROLLER
BATTERIES
-48 VDC
CONTROLLER
PHOTOVOLTAIC ARRAY
SUN POWER E20 -327
OUTDOOR GENERATOR
OUTDOOR GENERATOR
3 - 3/0 AWG
+1- #2 AWG GND
2" SCH 40
PVC CONDUIT
DC / DC
CONVERTER 24 VDC
DC POWER
PANEL
THIRD PARTY
CONTROLLER
(TYP 13 PL)
3 - 3/0 AWG
+1- #2 AWG GND
2" SCH 40
PVC CONDUIT
8 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH40
PVC CONDUIT
2 - #6 AWG
+1- #10 AWG GND
1" SCH 40
PVC CONDUIT
6 - #6 AWG
+1- #10 AWG GND
1-1/4" SCH40
PVC CONDUIT
(3 EA)
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
RECTIFIER
J-BOX
2 - 12 AWG
+1- 12 AWG GND
(12 PL)
MICROWAVE
DC FANS
GEN LIGHTING
FUTURE
FUTURE
FUTURE
RADIO
RADIO
FUTURE
BLOCK HEATER
OIL HEATER
TIMER
LIGHTS GEN RM
BLOCK HEATER
LIGHTS EQ RM
HVAC
HVAC
FUTURE
FUTURE
FUTURE
FUTURE
FUTURE
ONE LINE
NEW - WITH EXISTING EXCEL TECH INVERTERS
PRELIMINARY
ONE - LINE
T6-01.00
NTS
WILDERNESSsharePorterEnterprisesPdf.SampleSolarPVArrayB.DWG
ONE LINE / ALTERNATE - EMERSON / GE
NEW -48 VDC INVERTERS
A
B
C
D
E
F
G Proprietary and Confidential
Company Name:
Date: Title:
Project Name:
Drawn:
Checked:
Engineer:
Project Mgr:
Approved:
Approved:
Serial Number: Dwg Number:
Scale:Project Location:
DO NOT SCALE DRAWING
Size:
D
Rev:
P ESystems Engineering Consultants
13323-226th Ave NE
Granite Falls, WA 98252
Phone (360) 691-1600
Fax (360) 691-1615