SlideShare a Scribd company logo
1 of 23
Download to read offline
1
Motor Basics
AGSM 325
Motors vs Engines
• Motors convert
electrical energy to
mechanical energy.
• Engines convert
chemical energy to
mechanical energy.
www.PAControl.com
2
Motors
• Advantages
– Low Initial Cost - $/Hp
– Simple & Efficient Operation
– Compact Size – cubic inches/Hp
– Long Life – 30,000 to 50,000 hours
– Low Noise
– No Exhaust Emissions
– Withstand high temporary overloads
– Automatic/Remote Start & Control
• Disadvantages
– Portability
– Speed Control
– No Demand Charge
Magnetic Induction
• Simple Electromagnet
• Like Poles Repel
• Opposite Poles Attract
www.PAControl.com
3
Operating Principle
Motor Parts
• Enclosure
• Stator
• Rotor
• Bearings
• Conduit Box
• Eye Bolt
www.PAControl.com
4
Enclosure
• Holds parts together
• Helps with heat dissipation
• In some cases, protects internal components
from the environment.
Stator (Windings)
• “Stationary” part of the motor sometimes referred to as “the
windings”.
• Slotted cores made of thin sections of soft iron are wound
with insulated copper wire to form one or more pairs of
magnetic poles.
www.PAControl.com
5
Rotor
• “Rotating” part of the
motor.
• Magnetic field from
the stator induces an
opposing magnetic
field onto the rotor
causing the rotor to
“push” away from the
stator field.
Wound Rotor Motors
• Older motor designed to operate at “variable speed”
• Advantages
– Speed Control, High Starting Torque, Low Starting Current
• Disadvantages
– Expensive, High Maintenance, Low Efficiency
www.PAControl.com
6
Bearings
• Sleeve Bearings
– Standard on most motors
– Quiet
– Horizontal shafts only
– Oil lubricated
• Ball (Roller) Bearings
– Support shaft in any
position
– Grease lubricated
– Many come sealed
requiring no maintenance
Other Parts
• Conduit Box
– Point of connection of
electrical power to the
motor’s stator windings.
• Eye Bolt
– Used to lift heavy motors
with a hoist or crane to
prevent motor damage.
www.PAControl.com
7
Motor Speed
• Synchronous Speed
– Speed the motor’s
magnetic field rotates.
– Theoretical speed with
not torque or friction.
• Rated Speed
– Speed the motor
operates when fully
loaded.
– Actual speed at full
load when supplied
rated voltage.
Synchronous Speed
• Theoretical Speed
• A well built motor may
approach synchronous
speed when it has no load.
• Factors
– Electrical Frequency
(cycles/second)
– # of poles in motor
www.PAControl.com
8
Rated Speed
• Speed the motor
runs at when fully
loaded and supplied
rated nameplate
voltage.
Motor Slip
• Percent difference between a motor’s
synchronous speed and rated speed.
• The rotor in an induction motor lags slightly
behind the synchronous speed of the changing
polarity of the magnetic field.
– Low Slip Motors
• “Stiff”….High Efficiency motors
– High Slip Motors
• Used for applications where load varies significantly…oil
pump jacks.
www.PAControl.com
9
Torque
• Measure of force
producing a rotation
– Turning Effort
– Measured in pound-feet
(foot-pounds)
Torque-Speed Curve
• Amount of Torque
produced by motors
varies with Speed.
• Torque Speed Curves
– Starting Torque
– Pull Up Torque
– Breakdown Torque
www.PAControl.com
10
Motor Power
• Output Power
– Horsepower
– Amount of power
motor can produce at
shaft and not reduce
life of motor.
• Input Power
– Kilowatts
– Amount of power the
motor consumes to
produce the output
power.
Calculating Horsepower
• Need Speed and
Torque
• Speed is easy
– Tachometer
• Torque is difficult
– Dynamometer
– Prony Brake
www.PAControl.com
11
Watt’s Law
• Input Power
• Single Phase
– Watts = Volts X Amps X p.f.
• Three Phase
– Watts = Avg Volts X Avg Amps X p.f. X 1.74
Example
• Is a 1 Hp 1-phase motor driving a fan overloaded?
– Voltage = 123 volts
– Current = 9 amps
– p.f. = 78%
• Watts = Volts X Amps X p.f.
Watts = 123 volts X 9 amps X 0.78 = 863.5 Watts
864 Watts / 746 Watts/Hp = 1.16 Hp
• Is the motor overloaded?
www.PAControl.com
12
Electrical = Input
• We measured Input
• Motors are rated as Output
• Difference?
– Efficiency
• If the motor is 75%
efficient, is it overloaded?
• Eff = Output / Input
• Output = Eff X Input
0.75 X 1.16 Hp = 0.87 Hp
• The motor is NOT
overloaded
1.16 Hp
Input
HP
Output?
Example #2
• Is this 10 Hp, 3-phase motor overloaded?
– Voltages = 455, 458, and 461 volts
– Currents = 14.1, 14.0 and 13.9 amps
– P.f. = 82%
• Watts = Voltsavg X Ampsavg X p.f. X 1.74
Watts = 458v X 14a X 0.82 X 1.74 = 9148.6 Watts
9148.6 Watts / 746 Watts/Hp = 12.26 Hp
• Is the motor overloaded?
www.PAControl.com
13
Example #2
• We measured Input
• Motor is rated as Output
• Difference?
– Efficiency
• If the motor is 90%
efficient, is it overloaded?
• Eff = Output / Input
• Output = Eff X Input
0.90 X 12.26 Hp = 11.0 Hp
• The motor IS overloaded!
• How bad is the overload?
12.26 Hp
Input
Hp
Output ?
Motor Types
CLASSIFICATION OF MOTORS
Synchronous Induction
Hysteresis
Reluctance
Permanent
Magnet
Wound Rotor
Synchronous
Squirrel
Cage Wound
Rotor
Design A
Design B
Design C
Design D
Synchronous Induction
Hysteresis
Reluctance
Wound
Rotor
Repulsion
Repulsion Start
Squirrel
Cage
Split Phase
Capacitor Run
Capacitor Start
Capacitor Start/Run
Polyphase Universal Single-Phase
AC MOTORS
www.PAControl.com
14
Synchronous vs Induction Motors
• Synchronous Motors
– Turn at exactly the
same speed as the
rotating magnetic field.
– 3600 rpm, 1800 rpm,
etc.
• Induction Motors
– Turn at less than
synchronous speed
under load.
– 3450 rpm, 1740 rpm,
etc.
NEMA 3 Phase Motors
• 3 Phase Induction
Motors
• NEMA Torque-
Speed Design
Types
– A,B,C,D,E
www.PAControl.com
15
Design Type B
• Today’s “Standard” 3-
Phase Motor
• Good Starting Torque
– In-rush amps 4-6 times
full load amps
– Good breakdown-
torque
– Medium Slip
Design Type A
• The “old” Standard
• Higher starting torque
than “B”.
• Higher in-rush current
(5-8 times full load
amps)
• Good breakdown
torque
www.PAControl.com
16
Design Type C
• Common OEM
equipment on
reciprocating pumps,
compressors and other
“hard starting” loads.
• High starting torque
• Moderate starting
current (5-8 times
FLA)
• Moderate breakdown
torque
Design Type D
• Common on
applications with
significant loading
changes as a machine
operates.
• Impact Loads
– Punch Presses, Metal
Shears, etc.
– Pump Jacks
www.PAControl.com
17
Design Type E
• Newest NEMA Category
• Newer ultra-high efficiency motors
– Higher Starting Torque
– Higher Starting Current (8-12 times Running)
– Ultra Low Slip (Higher Rated Speed)
Single Phase Induction Motors
• Are not “self starting”
– Require a starting mechanism.
• The name generally
describes its “starting
mechanism”.
– Split Phase
– Capacitor Run
– Capacitor Start
– Capacitor Start-Capacitor Run
– Shaded Pole
– Synchronous
– Universal
www.PAControl.com
18
Split Phase Motor
• Common small single
phase motor
– Good Starting Torque
– Moderate Efficiency
– Moderate Cost
• Small conveyors, augers,
pumps, and some
compressors
• 1/20th to ¾ Hp, available
to 1.5 Hp
Split Phase Motor
• Starting winding in
parallel with Running
winding
• Switch operates at
70-80% of full speed.
• Centrifugal Switch
– Sticks Open
– Sticks Shut
www.PAControl.com
19
Capacitor Run Motor
(Permanent Split Capacitor or PSC)
• Primarily a fan
and blower
motor.
• Poor starting
torque
• Very low cost
motor.
Permanent Split Capacitor (PSC)
• Capacitor in
“Capacitor Winding”
– Provides a “phase
shift” for starting.
– Optimizes running
characteristics.
• No centrifugal switch
www.PAControl.com
20
Capacitor Start Motor
• Larger single phase
motors up to about 10
Hp.
• A split phase motor
with the addition of a
capacitor in the
starting winding.
• Capacitor sized for
high starting torque.
Capacitor Start Motor
• Very high starting
torque.
• Very high starting
current.
• Common on
compressors and other
hard starting
equipment.
www.PAControl.com
21
Capacitor Start-Capacitor Run
• Both starting and
running characteristics
are optimized.
– High starting torque
– Low starting current
– Highest cost
• For hard starting loads
like compressors and
pumps.
• Up to 10 Hp or higher
is some situations.
Capacitor Start-Run Motor
• Larger single phase
motors up to 10 Hp.
• Good starting torque
(less than cap start)
with lower starting
current.
• Higher cost than cap
start.
www.PAControl.com
22
Synchronous Motor
• Special design for
“constant speed” at
rated horsepower and
below.
• Used where
maintaining speed is
critical when the load
changes.
Universal Motor
• Runs on AC or DC
• Commutator and
brushes
• Generally found in
portable power tools.
• Lower Hp sizes
www.PAControl.com
23
Universal Motor
• Very high starting
torque.
• Higher torque on DC
than AC (battery
operated tools)
• The higher the rpm,
the lower the torque.
www.PAControl.com

More Related Content

What's hot

Gearbox in automobile
Gearbox  in automobile Gearbox  in automobile
Gearbox in automobile
sgrsoni45
 
Motor Fundamental
Motor FundamentalMotor Fundamental
Motor Fundamental
rayhsu
 
Halderman ch054 lecture
Halderman ch054 lectureHalderman ch054 lecture
Halderman ch054 lecture
mcfalltj
 
Manual transmission system in automobiles
Manual transmission system in automobilesManual transmission system in automobiles
Manual transmission system in automobiles
chaudhryshailja
 

What's hot (19)

Sliding mesh gear box
Sliding mesh gear boxSliding mesh gear box
Sliding mesh gear box
 
Gearbox in automobile
Gearbox  in automobile Gearbox  in automobile
Gearbox in automobile
 
Hybrid hvac
Hybrid hvacHybrid hvac
Hybrid hvac
 
Power transmission system
Power transmission systemPower transmission system
Power transmission system
 
Motor Fundamental
Motor FundamentalMotor Fundamental
Motor Fundamental
 
Flywheel
FlywheelFlywheel
Flywheel
 
Automatic transmission.ppt
Automatic transmission.pptAutomatic transmission.ppt
Automatic transmission.ppt
 
Maintopik5
Maintopik5Maintopik5
Maintopik5
 
Gear1
Gear1Gear1
Gear1
 
Halderman ch054 lecture
Halderman ch054 lectureHalderman ch054 lecture
Halderman ch054 lecture
 
Hybrid safety
Hybrid safetyHybrid safety
Hybrid safety
 
Manual transmission final
Manual transmission finalManual transmission final
Manual transmission final
 
Me8099 -robotics-- unit-2
Me8099 -robotics-- unit-2Me8099 -robotics-- unit-2
Me8099 -robotics-- unit-2
 
Car Transmission System
Car Transmission SystemCar Transmission System
Car Transmission System
 
Manual transmission system in automobiles
Manual transmission system in automobilesManual transmission system in automobiles
Manual transmission system in automobiles
 
Gear box
Gear boxGear box
Gear box
 
Automatic transmission
Automatic transmissionAutomatic transmission
Automatic transmission
 
AUTOMATIC TRANSMISSION
AUTOMATIC TRANSMISSIONAUTOMATIC TRANSMISSION
AUTOMATIC TRANSMISSION
 
Shimpo rxc catalog
Shimpo rxc catalogShimpo rxc catalog
Shimpo rxc catalog
 

Similar to Tutorial motor-basics-lecture

The Best Motor for Hybrid Electric Vehicle Powertrains
The Best Motor for Hybrid Electric Vehicle PowertrainsThe Best Motor for Hybrid Electric Vehicle Powertrains
The Best Motor for Hybrid Electric Vehicle Powertrains
Design World
 
20620041 electrical-motors
20620041 electrical-motors20620041 electrical-motors
20620041 electrical-motors
Dodda Haralu
 
singlephasei-160810083049.pptx
singlephasei-160810083049.pptxsinglephasei-160810083049.pptx
singlephasei-160810083049.pptx
PersonalAccount10
 

Similar to Tutorial motor-basics-lecture (20)

The Best Motor for Hybrid Electric Vehicle Powertrains
The Best Motor for Hybrid Electric Vehicle PowertrainsThe Best Motor for Hybrid Electric Vehicle Powertrains
The Best Motor for Hybrid Electric Vehicle Powertrains
 
06.2010 fsae hybrid 2nd presentation gen-2 preliminary designs and hybrid c...
06.2010 fsae hybrid 2nd presentation   gen-2 preliminary designs and hybrid c...06.2010 fsae hybrid 2nd presentation   gen-2 preliminary designs and hybrid c...
06.2010 fsae hybrid 2nd presentation gen-2 preliminary designs and hybrid c...
 
Single phase induction motor
Single phase induction motorSingle phase induction motor
Single phase induction motor
 
20620041 electrical-motors
20620041 electrical-motors20620041 electrical-motors
20620041 electrical-motors
 
12_Y NGM MSKM-TS.ppt
12_Y NGM MSKM-TS.ppt12_Y NGM MSKM-TS.ppt
12_Y NGM MSKM-TS.ppt
 
Motors
Motors Motors
Motors
 
Capacitor motor
Capacitor motorCapacitor motor
Capacitor motor
 
Vaibhav gautam (electric vehicle file )
Vaibhav gautam (electric vehicle file )Vaibhav gautam (electric vehicle file )
Vaibhav gautam (electric vehicle file )
 
Lec 04(actuators).pdf
Lec 04(actuators).pdfLec 04(actuators).pdf
Lec 04(actuators).pdf
 
How to Start your Large Motors- typical Solutions or new motor design?
How to Start your Large Motors- typical Solutions or new motor design?How to Start your Large Motors- typical Solutions or new motor design?
How to Start your Large Motors- typical Solutions or new motor design?
 
Comparison and analysis of electrical motor used in Electric Vehicles..
Comparison and analysis of electrical motor used in Electric Vehicles..Comparison and analysis of electrical motor used in Electric Vehicles..
Comparison and analysis of electrical motor used in Electric Vehicles..
 
MECHATRONICS-UNIT 5-ACTUATORS AND MECHATRONICS SYSTEMS DESIGN.ppt
MECHATRONICS-UNIT 5-ACTUATORS AND MECHATRONICS SYSTEMS DESIGN.pptMECHATRONICS-UNIT 5-ACTUATORS AND MECHATRONICS SYSTEMS DESIGN.ppt
MECHATRONICS-UNIT 5-ACTUATORS AND MECHATRONICS SYSTEMS DESIGN.ppt
 
Starting and cooling methodes of motor
Starting and cooling methodes of motorStarting and cooling methodes of motor
Starting and cooling methodes of motor
 
generators
generatorsgenerators
generators
 
renewableresources-161014163807 (1).pdf
renewableresources-161014163807 (1).pdfrenewableresources-161014163807 (1).pdf
renewableresources-161014163807 (1).pdf
 
Single phase i.m.
Single phase i.m.Single phase i.m.
Single phase i.m.
 
singlephasei-160810083049.pptx
singlephasei-160810083049.pptxsinglephasei-160810083049.pptx
singlephasei-160810083049.pptx
 
62668724c2f9bSTARTING SYSTEM final ppt.pdf
62668724c2f9bSTARTING SYSTEM final ppt.pdf62668724c2f9bSTARTING SYSTEM final ppt.pdf
62668724c2f9bSTARTING SYSTEM final ppt.pdf
 
single phase Induction Motor-types, construction working.pptx
single phase Induction Motor-types, construction working.pptxsingle phase Induction Motor-types, construction working.pptx
single phase Induction Motor-types, construction working.pptx
 
Motors
MotorsMotors
Motors
 

Recently uploaded

Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
daisycvs
 
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabiunwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
Abortion pills in Kuwait Cytotec pills in Kuwait
 
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
amitlee9823
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
amitlee9823
 
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
dlhescort
 
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
amitlee9823
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
dollysharma2066
 

Recently uploaded (20)

(Anamika) VIP Call Girls Napur Call Now 8617697112 Napur Escorts 24x7
(Anamika) VIP Call Girls Napur Call Now 8617697112 Napur Escorts 24x7(Anamika) VIP Call Girls Napur Call Now 8617697112 Napur Escorts 24x7
(Anamika) VIP Call Girls Napur Call Now 8617697112 Napur Escorts 24x7
 
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
Quick Doctor In Kuwait +2773`7758`557 Kuwait Doha Qatar Dubai Abu Dhabi Sharj...
 
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 MonthsSEO Case Study: How I Increased SEO Traffic & Ranking by 50-60%  in 6 Months
SEO Case Study: How I Increased SEO Traffic & Ranking by 50-60% in 6 Months
 
Organizational Transformation Lead with Culture
Organizational Transformation Lead with CultureOrganizational Transformation Lead with Culture
Organizational Transformation Lead with Culture
 
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabiunwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
unwanted pregnancy Kit [+918133066128] Abortion Pills IN Dubai UAE Abudhabi
 
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
👉Chandigarh Call Girls 👉9878799926👉Just Call👉Chandigarh Call Girl In Chandiga...
 
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
Call Girls Kengeri Satellite Town Just Call 👗 7737669865 👗 Top Class Call Gir...
 
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesMysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
 
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRLBAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
BAGALUR CALL GIRL IN 98274*61493 ❤CALL GIRLS IN ESCORT SERVICE❤CALL GIRL
 
Call Girls Service In Old Town Dubai ((0551707352)) Old Town Dubai Call Girl ...
Call Girls Service In Old Town Dubai ((0551707352)) Old Town Dubai Call Girl ...Call Girls Service In Old Town Dubai ((0551707352)) Old Town Dubai Call Girl ...
Call Girls Service In Old Town Dubai ((0551707352)) Old Town Dubai Call Girl ...
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 May
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
 
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
Cheap Rate Call Girls In Noida Sector 62 Metro 959961乂3876
 
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
Call Girls In Majnu Ka Tilla 959961~3876 Shot 2000 Night 8000
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
 
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
 
Marel Q1 2024 Investor Presentation from May 8, 2024
Marel Q1 2024 Investor Presentation from May 8, 2024Marel Q1 2024 Investor Presentation from May 8, 2024
Marel Q1 2024 Investor Presentation from May 8, 2024
 
Falcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business GrowthFalcon Invoice Discounting: Empowering Your Business Growth
Falcon Invoice Discounting: Empowering Your Business Growth
 
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Majnu Ka Tilla, Delhi Contact Us 8377877756
 
Uneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration PresentationUneak White's Personal Brand Exploration Presentation
Uneak White's Personal Brand Exploration Presentation
 

Tutorial motor-basics-lecture

  • 1. 1 Motor Basics AGSM 325 Motors vs Engines • Motors convert electrical energy to mechanical energy. • Engines convert chemical energy to mechanical energy. www.PAControl.com
  • 2. 2 Motors • Advantages – Low Initial Cost - $/Hp – Simple & Efficient Operation – Compact Size – cubic inches/Hp – Long Life – 30,000 to 50,000 hours – Low Noise – No Exhaust Emissions – Withstand high temporary overloads – Automatic/Remote Start & Control • Disadvantages – Portability – Speed Control – No Demand Charge Magnetic Induction • Simple Electromagnet • Like Poles Repel • Opposite Poles Attract www.PAControl.com
  • 3. 3 Operating Principle Motor Parts • Enclosure • Stator • Rotor • Bearings • Conduit Box • Eye Bolt www.PAControl.com
  • 4. 4 Enclosure • Holds parts together • Helps with heat dissipation • In some cases, protects internal components from the environment. Stator (Windings) • “Stationary” part of the motor sometimes referred to as “the windings”. • Slotted cores made of thin sections of soft iron are wound with insulated copper wire to form one or more pairs of magnetic poles. www.PAControl.com
  • 5. 5 Rotor • “Rotating” part of the motor. • Magnetic field from the stator induces an opposing magnetic field onto the rotor causing the rotor to “push” away from the stator field. Wound Rotor Motors • Older motor designed to operate at “variable speed” • Advantages – Speed Control, High Starting Torque, Low Starting Current • Disadvantages – Expensive, High Maintenance, Low Efficiency www.PAControl.com
  • 6. 6 Bearings • Sleeve Bearings – Standard on most motors – Quiet – Horizontal shafts only – Oil lubricated • Ball (Roller) Bearings – Support shaft in any position – Grease lubricated – Many come sealed requiring no maintenance Other Parts • Conduit Box – Point of connection of electrical power to the motor’s stator windings. • Eye Bolt – Used to lift heavy motors with a hoist or crane to prevent motor damage. www.PAControl.com
  • 7. 7 Motor Speed • Synchronous Speed – Speed the motor’s magnetic field rotates. – Theoretical speed with not torque or friction. • Rated Speed – Speed the motor operates when fully loaded. – Actual speed at full load when supplied rated voltage. Synchronous Speed • Theoretical Speed • A well built motor may approach synchronous speed when it has no load. • Factors – Electrical Frequency (cycles/second) – # of poles in motor www.PAControl.com
  • 8. 8 Rated Speed • Speed the motor runs at when fully loaded and supplied rated nameplate voltage. Motor Slip • Percent difference between a motor’s synchronous speed and rated speed. • The rotor in an induction motor lags slightly behind the synchronous speed of the changing polarity of the magnetic field. – Low Slip Motors • “Stiff”….High Efficiency motors – High Slip Motors • Used for applications where load varies significantly…oil pump jacks. www.PAControl.com
  • 9. 9 Torque • Measure of force producing a rotation – Turning Effort – Measured in pound-feet (foot-pounds) Torque-Speed Curve • Amount of Torque produced by motors varies with Speed. • Torque Speed Curves – Starting Torque – Pull Up Torque – Breakdown Torque www.PAControl.com
  • 10. 10 Motor Power • Output Power – Horsepower – Amount of power motor can produce at shaft and not reduce life of motor. • Input Power – Kilowatts – Amount of power the motor consumes to produce the output power. Calculating Horsepower • Need Speed and Torque • Speed is easy – Tachometer • Torque is difficult – Dynamometer – Prony Brake www.PAControl.com
  • 11. 11 Watt’s Law • Input Power • Single Phase – Watts = Volts X Amps X p.f. • Three Phase – Watts = Avg Volts X Avg Amps X p.f. X 1.74 Example • Is a 1 Hp 1-phase motor driving a fan overloaded? – Voltage = 123 volts – Current = 9 amps – p.f. = 78% • Watts = Volts X Amps X p.f. Watts = 123 volts X 9 amps X 0.78 = 863.5 Watts 864 Watts / 746 Watts/Hp = 1.16 Hp • Is the motor overloaded? www.PAControl.com
  • 12. 12 Electrical = Input • We measured Input • Motors are rated as Output • Difference? – Efficiency • If the motor is 75% efficient, is it overloaded? • Eff = Output / Input • Output = Eff X Input 0.75 X 1.16 Hp = 0.87 Hp • The motor is NOT overloaded 1.16 Hp Input HP Output? Example #2 • Is this 10 Hp, 3-phase motor overloaded? – Voltages = 455, 458, and 461 volts – Currents = 14.1, 14.0 and 13.9 amps – P.f. = 82% • Watts = Voltsavg X Ampsavg X p.f. X 1.74 Watts = 458v X 14a X 0.82 X 1.74 = 9148.6 Watts 9148.6 Watts / 746 Watts/Hp = 12.26 Hp • Is the motor overloaded? www.PAControl.com
  • 13. 13 Example #2 • We measured Input • Motor is rated as Output • Difference? – Efficiency • If the motor is 90% efficient, is it overloaded? • Eff = Output / Input • Output = Eff X Input 0.90 X 12.26 Hp = 11.0 Hp • The motor IS overloaded! • How bad is the overload? 12.26 Hp Input Hp Output ? Motor Types CLASSIFICATION OF MOTORS Synchronous Induction Hysteresis Reluctance Permanent Magnet Wound Rotor Synchronous Squirrel Cage Wound Rotor Design A Design B Design C Design D Synchronous Induction Hysteresis Reluctance Wound Rotor Repulsion Repulsion Start Squirrel Cage Split Phase Capacitor Run Capacitor Start Capacitor Start/Run Polyphase Universal Single-Phase AC MOTORS www.PAControl.com
  • 14. 14 Synchronous vs Induction Motors • Synchronous Motors – Turn at exactly the same speed as the rotating magnetic field. – 3600 rpm, 1800 rpm, etc. • Induction Motors – Turn at less than synchronous speed under load. – 3450 rpm, 1740 rpm, etc. NEMA 3 Phase Motors • 3 Phase Induction Motors • NEMA Torque- Speed Design Types – A,B,C,D,E www.PAControl.com
  • 15. 15 Design Type B • Today’s “Standard” 3- Phase Motor • Good Starting Torque – In-rush amps 4-6 times full load amps – Good breakdown- torque – Medium Slip Design Type A • The “old” Standard • Higher starting torque than “B”. • Higher in-rush current (5-8 times full load amps) • Good breakdown torque www.PAControl.com
  • 16. 16 Design Type C • Common OEM equipment on reciprocating pumps, compressors and other “hard starting” loads. • High starting torque • Moderate starting current (5-8 times FLA) • Moderate breakdown torque Design Type D • Common on applications with significant loading changes as a machine operates. • Impact Loads – Punch Presses, Metal Shears, etc. – Pump Jacks www.PAControl.com
  • 17. 17 Design Type E • Newest NEMA Category • Newer ultra-high efficiency motors – Higher Starting Torque – Higher Starting Current (8-12 times Running) – Ultra Low Slip (Higher Rated Speed) Single Phase Induction Motors • Are not “self starting” – Require a starting mechanism. • The name generally describes its “starting mechanism”. – Split Phase – Capacitor Run – Capacitor Start – Capacitor Start-Capacitor Run – Shaded Pole – Synchronous – Universal www.PAControl.com
  • 18. 18 Split Phase Motor • Common small single phase motor – Good Starting Torque – Moderate Efficiency – Moderate Cost • Small conveyors, augers, pumps, and some compressors • 1/20th to ¾ Hp, available to 1.5 Hp Split Phase Motor • Starting winding in parallel with Running winding • Switch operates at 70-80% of full speed. • Centrifugal Switch – Sticks Open – Sticks Shut www.PAControl.com
  • 19. 19 Capacitor Run Motor (Permanent Split Capacitor or PSC) • Primarily a fan and blower motor. • Poor starting torque • Very low cost motor. Permanent Split Capacitor (PSC) • Capacitor in “Capacitor Winding” – Provides a “phase shift” for starting. – Optimizes running characteristics. • No centrifugal switch www.PAControl.com
  • 20. 20 Capacitor Start Motor • Larger single phase motors up to about 10 Hp. • A split phase motor with the addition of a capacitor in the starting winding. • Capacitor sized for high starting torque. Capacitor Start Motor • Very high starting torque. • Very high starting current. • Common on compressors and other hard starting equipment. www.PAControl.com
  • 21. 21 Capacitor Start-Capacitor Run • Both starting and running characteristics are optimized. – High starting torque – Low starting current – Highest cost • For hard starting loads like compressors and pumps. • Up to 10 Hp or higher is some situations. Capacitor Start-Run Motor • Larger single phase motors up to 10 Hp. • Good starting torque (less than cap start) with lower starting current. • Higher cost than cap start. www.PAControl.com
  • 22. 22 Synchronous Motor • Special design for “constant speed” at rated horsepower and below. • Used where maintaining speed is critical when the load changes. Universal Motor • Runs on AC or DC • Commutator and brushes • Generally found in portable power tools. • Lower Hp sizes www.PAControl.com
  • 23. 23 Universal Motor • Very high starting torque. • Higher torque on DC than AC (battery operated tools) • The higher the rpm, the lower the torque. www.PAControl.com