04 Statistics for Traffic Engineers (Traffic Engineering هندسة المرور & Prof....Hossam Shafiq I
This document appears to be lecture slides from a traffic engineering course taught by Prof. Saad AlGadhi at King Saud University. It covers topics in statistics for traffic engineers, including confidence intervals, hypothesis testing using the chi-squared test, and provides an example comparing spot speed data to a hypothesized normal distribution. It also announces homework assignments from chapter 7 in the textbook are due the following Wednesday.
This document discusses geometric design standards for airport runway exits and taxiways according to FAA guidelines. It provides examples of right-angle, 45-degree, and 30-degree runway exits. Issues with design such as limited visibility and separation distances are also examined. Dimension standards for taxiway junctions are presented from FAA design tables. Examples of implementations at airports are shown through diagrams and aerial images.
1a iii classification of cross section for rolled sectionsSudhir Gayake
This document discusses the classification of cross-sectional shapes according to their ability to form plastic hinges and resist local buckling. It defines four classes of cross-sections: plastic, compact, semi-compact, and slender. Plastic sections can develop plastic hinges, compact sections can develop plastic moments but have inadequate rotation, semi-compact sections can reach yield stress but not plastic moments due to buckling, and slender sections buckle before yield. The document provides limiting width-to-thickness ratios for each class and works through numerical examples to classify I-beams, channels, and angles.
This document discusses different types of stresses including normal stress, shear stress, bearing stress, and stresses in thin-walled pressure vessels. It provides definitions and formulas for calculating normal stress, shear stress, and bearing stress. For thin-walled pressure vessels, it explains that the tangential stress is twice the longitudinal stress and provides the formulas for calculating each. It also includes example problems calculating stresses in cylindrical and spherical pressure vessels.
This document discusses various road safety measures that can be implemented at junctions to reduce traffic accidents. It describes junction layout treatments such as converting intersections to roundabouts, redesigning junctions, and staggered junctions. It also discusses traffic control treatments like implementing yield or stop signs and traffic signals. Research findings show that roundabouts and junction redesign can reduce injury accidents by up to 85% depending on the initial junction type and characteristics. Installing traffic control signs and signals and optimizing signal timing also effectively reduces accidents. The document analyzes the safety and other impacts of different junction improvements and traffic management strategies.
1. This document contains definitions and concepts related to leveling, contouring, theodolite surveying, traversing, tacheometry, and curves. It defines key terms like benchmark, line of collimation, height of instrument, change point, contour, horizontal equivalent, deflection angle, latitude and departure.
2. Methods of leveling like fly leveling are described. Concepts explained in contouring include contour line, contour interval, horizontal equivalent, distinguishing valley and ridge lines.
3. Theodolite surveying concepts covered are transiting, telescope normal, least count, fundamental lines. Traversing defines closed and open traverses and methods to balance them.
4. T
04 Statistics for Traffic Engineers (Traffic Engineering هندسة المرور & Prof....Hossam Shafiq I
This document appears to be lecture slides from a traffic engineering course taught by Prof. Saad AlGadhi at King Saud University. It covers topics in statistics for traffic engineers, including confidence intervals, hypothesis testing using the chi-squared test, and provides an example comparing spot speed data to a hypothesized normal distribution. It also announces homework assignments from chapter 7 in the textbook are due the following Wednesday.
This document discusses geometric design standards for airport runway exits and taxiways according to FAA guidelines. It provides examples of right-angle, 45-degree, and 30-degree runway exits. Issues with design such as limited visibility and separation distances are also examined. Dimension standards for taxiway junctions are presented from FAA design tables. Examples of implementations at airports are shown through diagrams and aerial images.
1a iii classification of cross section for rolled sectionsSudhir Gayake
This document discusses the classification of cross-sectional shapes according to their ability to form plastic hinges and resist local buckling. It defines four classes of cross-sections: plastic, compact, semi-compact, and slender. Plastic sections can develop plastic hinges, compact sections can develop plastic moments but have inadequate rotation, semi-compact sections can reach yield stress but not plastic moments due to buckling, and slender sections buckle before yield. The document provides limiting width-to-thickness ratios for each class and works through numerical examples to classify I-beams, channels, and angles.
This document discusses different types of stresses including normal stress, shear stress, bearing stress, and stresses in thin-walled pressure vessels. It provides definitions and formulas for calculating normal stress, shear stress, and bearing stress. For thin-walled pressure vessels, it explains that the tangential stress is twice the longitudinal stress and provides the formulas for calculating each. It also includes example problems calculating stresses in cylindrical and spherical pressure vessels.
This document discusses various road safety measures that can be implemented at junctions to reduce traffic accidents. It describes junction layout treatments such as converting intersections to roundabouts, redesigning junctions, and staggered junctions. It also discusses traffic control treatments like implementing yield or stop signs and traffic signals. Research findings show that roundabouts and junction redesign can reduce injury accidents by up to 85% depending on the initial junction type and characteristics. Installing traffic control signs and signals and optimizing signal timing also effectively reduces accidents. The document analyzes the safety and other impacts of different junction improvements and traffic management strategies.
1. This document contains definitions and concepts related to leveling, contouring, theodolite surveying, traversing, tacheometry, and curves. It defines key terms like benchmark, line of collimation, height of instrument, change point, contour, horizontal equivalent, deflection angle, latitude and departure.
2. Methods of leveling like fly leveling are described. Concepts explained in contouring include contour line, contour interval, horizontal equivalent, distinguishing valley and ridge lines.
3. Theodolite surveying concepts covered are transiting, telescope normal, least count, fundamental lines. Traversing defines closed and open traverses and methods to balance them.
4. T
The document summarizes the history and current status of Pakistan's motorway system. It begins with a brief history of road construction dating back to ancient Rome and Egypt. It then provides details on 15 existing and planned motorways in Pakistan, including their planned completion dates, lengths, number of lanes and exits. The total length of operational motorways has grown from 632 km in 2010 to over 1,000 km presently. The first motorway opened in 1997 between Peshawar and Islamabad.
The document discusses a traffic volume study conducted at Russell Square in Dhaka. It defines key terms like average daily traffic (ADT) and level of service (LOS). Data was collected manually over three hours and analyzed to find a service flow rate of 1,131 passenger car units per hour, indicating an LOS of D. The average daily traffic was calculated as 16,080 passenger cars with an annual average of 22,432. Traffic movement was found to be nearly equal in both directions.
Here are the key steps and calculations for the homework:
1. Use design speed of 55 mph, emax of 4%, and fmax of 0.12 from Green Book
2. Calculate minimum radius using formula: Rmin = V2/(15(e+f)) = 1,200 ft
3. Select radius of 1,400 ft
4. Given: PI station of 352+44.97, Δ of 35° 24' 55"
5. Calculate curve length using L = ΔR/5729.58 = 1,260 ft
6. Calculate tangent length using T = Rtan(Δ/2) = 630 ft
7. Calculate PC station: PC = PI - T
The document discusses different types of pavements, including flexible, rigid, semi-rigid, earthen, and WBM (water bound macadam) roads. Flexible pavements are made of asphaltic or bituminous material mixed with aggregates. Rigid pavements are made of concrete and have higher initial costs but lower long-term maintenance costs. Semi-rigid pavements use materials like lean cement concrete or soil cement that provide some rigidity. Earthen roads are simply made from native soils and become muddy when wet. WBM roads involve compacting gravel layers with water.
The document provides information on column design according to BS 8110-1:1997, including general recommendations, classifications of columns, effective length and minimum eccentricity, design moments, and design. Short columns have a length to height or breadth ratio less than 15 for braced or 10 for unbraced. Braced columns have lateral stability from walls or bracing. Additional moments are considered for slender or unbraced columns based on deflection. Design moments are calculated considering axial load and biaxial bending for different column classifications. Shear design also considers axial load and reinforcement is required if shear exceeds the shear capacity. The interaction diagram is constructed based on equilibrium equations relating stresses on a column cross section to axial load and bending
The document provides information about streets, transportation, and public transit in Ahmedabad, India. It discusses the importance of streets and qualities of good street design, including accessibility, safety, and accommodating multiple modes of transportation. It also describes different street network patterns and elements of the right of way. The document then covers traffic concepts like capacity and level of service. It discusses public transit in Ahmedabad, including key metrics for the bus system. It compares Ahmedabad's transit to other cities. Finally, it presents next steps around defining street hierarchies and integrating public transit and street activities.
A cantilever beam is a rigid bar or beam fixed at one end and free at the other. This document discusses calculating the deflection and slope of a cantilever beam with an end load using the double integration method. It defines slope as the angle between the tangent line and original axis, and deflection as the distance between the beam's positions before and after loading. An example problem is presented of finding these values for a cantilever beam fixed at point A carrying a load at the free end B.
Types of intersection of road and design parameters of road intersectionwaiseee
This document provides information about types of road intersections and design parameters. It discusses two main types of intersections: grade-separated intersections which use bridges or tunnels to separate opposing traffic, and at-grade intersections where traffic crosses at the same level. Several specific intersection designs are described such as diamond, cloverleaf, and roundabout. Key design parameters for pedestrians, bicyclists, vehicles, and traffic control are also outlined.
1. Tension members are structural members subjected to axial pulling forces that cause elongation. Examples include wire ropes, stayed bridge decks, and bottom chords of trusses.
2. The design strength of a tension member must be greater than the factored tensile force and is limited by either yielding of the gross section, rupture of the critical section, or block shear failure.
3. Design of tension members considers the type of cross section, connections, and calculations of design strength based on yield strength, ultimate strength, and factors of safety. Safety is checked against tension, shear, and block shear failure modes.
The document provides steps for designing different structural elements:
1. Design of a beam subjected to torsion including calculation of torsional and bending moments, determination of steel requirements, and detailing.
2. Design of continuous beams involving calculation of bending moments and shears, reinforcement sizing, shear design, deflection check, and detailing including curtailment.
3. Design of circular water tanks with both flexible base and rigid base using approximate and IS code methods. This includes sizing hoop and vertical tension reinforcement, sizing wall thickness, designing cantilever sections and base slabs, and providing detailing diagrams.
The document contains plans for a 3 storey dormitory building including a roof framing plan and section details. The roof will consist of rectangular hollow core steel trusses spaced at 400mm with 50mm x 80mm C-purlins and a 1" x 8" facia board. The trusses will have a top chord of RHS 100 x 150 x 8, web of RHS 200 x 150 x 8, and bottom chord of RHS 100 x 150 x 8 connected by M16 anchor bolts. The roof will be covered with 25mm thick plaster and GI sheet roofing.
The document discusses various aspects of freeway design including widening curves, using islands, types of interchanges, and entrance and exit design. It describes the purposes of islands in design and different types of interchanges such as cloverleaf, stack, turbine, and others. Ramp designs and the functions of two-way, three-way, and four-way interchanges are also covered.
This document provides details for the construction of a swimming pool, including reinforcement bar layout, concrete specifications, and general notes. The swimming pool will be constructed with Grade 35A concrete for the walls and base. Reinforcement steel will have a minimum characteristic strength of 460N/mm2. All reinforcement bar laps will be a minimum of 50 times the bar diameter. The foundation is designed for a soil bearing capacity of 200 kN/m2.
This document contains floor plans for a proposed police station in Garda, Somalia. It includes two floor plans at a scale of 1:100: one for the proposed police station block and one for the proposed community policing block. The plans show the layouts of rooms including cells, offices, corridors, and washrooms. Dimensions are provided in millimeters. There are also schedules listing doors and windows along with notes on structural timber, fire safety, and revisions.
Surveying Engineering
Traversing Practical part 1
Plane and Applied surveying 2
Report number(2)
• Report name :Gales Traverse Table(Horizontal angle
measurement (FL)of closed traversing
• Apparatus
• Theodolite Instrument
• Tripod
• Compass
• Pin
• Tape
• Range pole
Object
• To conducted survey work in a closed traversing and calculate
in depend coordinates and area calculation by coordinate rule.
Procedure Traverse;
Calculations Traverse .Dada Sheet and Table method work clock wise surveying
-Gales Traverse Table.
*Traverse Calculations
-Traverse Calculation.
-Coordinate conversions.
-Signs of Departures and Latitudes.
*Balancing latitude and departure
-Correction for ∆E& ∆N:
Bowditch adjustment or compass method
-The example…
-Vector components (pre-adjustment)
*The adjustment components
Prepared by:
Asst. Prof. Salar K.Hussein
Mr. Kamal Y.Abdullah
Asst.Lecturer. Dilveen H. Omar
Erbil Polytechnic University
Technical Engineering College
Civil Engineering Department
This document defines key terms related to road geometrics and cross sections. It discusses the carriageway as the portion for vehicular traffic, road shoulders for emergency use and protecting edges, and formation width as the road embankment width including carriageway and shoulders. It also covers side slopes for embankment/cutting stability, berms between embankments and drains, road margins as land widths with possible inclusions, right of way as acquired land area, and camber and gradients as providing drainage and vehicle regulation.
This document provides guidelines for safer road design in cities. It summarizes traffic fatality rates in various global and Indian cities. It identifies vulnerable road users like children, pedestrians, and two-wheeler riders that account for many deaths in India. Design principles are outlined like shorter block lengths, density near transit, and access to destinations to reduce vehicle travel. Measures to improve safety in Indian cities are proposed like road diets, pedestrian refuge islands, and shared spaces. A collaborative process is recommended involving stakeholders to identify high-risk points and align priorities. Guidelines must be tailored and complemented with audits, policies and community insights for effective implementation of safer city designs.
The document provides an overview of valve and actuator products from a company that has been developing, producing, and selling industrial valves and actuators for over 40 years. It employs around 1,000 people across multiple production locations and subsidiaries globally. The company offers a wide range of valve types, including resilient seated valves, PTFE valves, high performance valves, knife gate valves, and special application valves. It prides itself on outstanding quality and customized solutions through precise coordination of valves, actuators, and automation technology.
The range of JLX bellows seal valves is basically designed to eliminate one of the most serious and frequent problems in steam and thermal fluid installations.
This is the leakage through the gland, that can be the reason of unforeseen maintenance shutdowns, with the consequent cost due to loss of energy.
The document summarizes the history and current status of Pakistan's motorway system. It begins with a brief history of road construction dating back to ancient Rome and Egypt. It then provides details on 15 existing and planned motorways in Pakistan, including their planned completion dates, lengths, number of lanes and exits. The total length of operational motorways has grown from 632 km in 2010 to over 1,000 km presently. The first motorway opened in 1997 between Peshawar and Islamabad.
The document discusses a traffic volume study conducted at Russell Square in Dhaka. It defines key terms like average daily traffic (ADT) and level of service (LOS). Data was collected manually over three hours and analyzed to find a service flow rate of 1,131 passenger car units per hour, indicating an LOS of D. The average daily traffic was calculated as 16,080 passenger cars with an annual average of 22,432. Traffic movement was found to be nearly equal in both directions.
Here are the key steps and calculations for the homework:
1. Use design speed of 55 mph, emax of 4%, and fmax of 0.12 from Green Book
2. Calculate minimum radius using formula: Rmin = V2/(15(e+f)) = 1,200 ft
3. Select radius of 1,400 ft
4. Given: PI station of 352+44.97, Δ of 35° 24' 55"
5. Calculate curve length using L = ΔR/5729.58 = 1,260 ft
6. Calculate tangent length using T = Rtan(Δ/2) = 630 ft
7. Calculate PC station: PC = PI - T
The document discusses different types of pavements, including flexible, rigid, semi-rigid, earthen, and WBM (water bound macadam) roads. Flexible pavements are made of asphaltic or bituminous material mixed with aggregates. Rigid pavements are made of concrete and have higher initial costs but lower long-term maintenance costs. Semi-rigid pavements use materials like lean cement concrete or soil cement that provide some rigidity. Earthen roads are simply made from native soils and become muddy when wet. WBM roads involve compacting gravel layers with water.
The document provides information on column design according to BS 8110-1:1997, including general recommendations, classifications of columns, effective length and minimum eccentricity, design moments, and design. Short columns have a length to height or breadth ratio less than 15 for braced or 10 for unbraced. Braced columns have lateral stability from walls or bracing. Additional moments are considered for slender or unbraced columns based on deflection. Design moments are calculated considering axial load and biaxial bending for different column classifications. Shear design also considers axial load and reinforcement is required if shear exceeds the shear capacity. The interaction diagram is constructed based on equilibrium equations relating stresses on a column cross section to axial load and bending
The document provides information about streets, transportation, and public transit in Ahmedabad, India. It discusses the importance of streets and qualities of good street design, including accessibility, safety, and accommodating multiple modes of transportation. It also describes different street network patterns and elements of the right of way. The document then covers traffic concepts like capacity and level of service. It discusses public transit in Ahmedabad, including key metrics for the bus system. It compares Ahmedabad's transit to other cities. Finally, it presents next steps around defining street hierarchies and integrating public transit and street activities.
A cantilever beam is a rigid bar or beam fixed at one end and free at the other. This document discusses calculating the deflection and slope of a cantilever beam with an end load using the double integration method. It defines slope as the angle between the tangent line and original axis, and deflection as the distance between the beam's positions before and after loading. An example problem is presented of finding these values for a cantilever beam fixed at point A carrying a load at the free end B.
Types of intersection of road and design parameters of road intersectionwaiseee
This document provides information about types of road intersections and design parameters. It discusses two main types of intersections: grade-separated intersections which use bridges or tunnels to separate opposing traffic, and at-grade intersections where traffic crosses at the same level. Several specific intersection designs are described such as diamond, cloverleaf, and roundabout. Key design parameters for pedestrians, bicyclists, vehicles, and traffic control are also outlined.
1. Tension members are structural members subjected to axial pulling forces that cause elongation. Examples include wire ropes, stayed bridge decks, and bottom chords of trusses.
2. The design strength of a tension member must be greater than the factored tensile force and is limited by either yielding of the gross section, rupture of the critical section, or block shear failure.
3. Design of tension members considers the type of cross section, connections, and calculations of design strength based on yield strength, ultimate strength, and factors of safety. Safety is checked against tension, shear, and block shear failure modes.
The document provides steps for designing different structural elements:
1. Design of a beam subjected to torsion including calculation of torsional and bending moments, determination of steel requirements, and detailing.
2. Design of continuous beams involving calculation of bending moments and shears, reinforcement sizing, shear design, deflection check, and detailing including curtailment.
3. Design of circular water tanks with both flexible base and rigid base using approximate and IS code methods. This includes sizing hoop and vertical tension reinforcement, sizing wall thickness, designing cantilever sections and base slabs, and providing detailing diagrams.
The document contains plans for a 3 storey dormitory building including a roof framing plan and section details. The roof will consist of rectangular hollow core steel trusses spaced at 400mm with 50mm x 80mm C-purlins and a 1" x 8" facia board. The trusses will have a top chord of RHS 100 x 150 x 8, web of RHS 200 x 150 x 8, and bottom chord of RHS 100 x 150 x 8 connected by M16 anchor bolts. The roof will be covered with 25mm thick plaster and GI sheet roofing.
The document discusses various aspects of freeway design including widening curves, using islands, types of interchanges, and entrance and exit design. It describes the purposes of islands in design and different types of interchanges such as cloverleaf, stack, turbine, and others. Ramp designs and the functions of two-way, three-way, and four-way interchanges are also covered.
This document provides details for the construction of a swimming pool, including reinforcement bar layout, concrete specifications, and general notes. The swimming pool will be constructed with Grade 35A concrete for the walls and base. Reinforcement steel will have a minimum characteristic strength of 460N/mm2. All reinforcement bar laps will be a minimum of 50 times the bar diameter. The foundation is designed for a soil bearing capacity of 200 kN/m2.
This document contains floor plans for a proposed police station in Garda, Somalia. It includes two floor plans at a scale of 1:100: one for the proposed police station block and one for the proposed community policing block. The plans show the layouts of rooms including cells, offices, corridors, and washrooms. Dimensions are provided in millimeters. There are also schedules listing doors and windows along with notes on structural timber, fire safety, and revisions.
Surveying Engineering
Traversing Practical part 1
Plane and Applied surveying 2
Report number(2)
• Report name :Gales Traverse Table(Horizontal angle
measurement (FL)of closed traversing
• Apparatus
• Theodolite Instrument
• Tripod
• Compass
• Pin
• Tape
• Range pole
Object
• To conducted survey work in a closed traversing and calculate
in depend coordinates and area calculation by coordinate rule.
Procedure Traverse;
Calculations Traverse .Dada Sheet and Table method work clock wise surveying
-Gales Traverse Table.
*Traverse Calculations
-Traverse Calculation.
-Coordinate conversions.
-Signs of Departures and Latitudes.
*Balancing latitude and departure
-Correction for ∆E& ∆N:
Bowditch adjustment or compass method
-The example…
-Vector components (pre-adjustment)
*The adjustment components
Prepared by:
Asst. Prof. Salar K.Hussein
Mr. Kamal Y.Abdullah
Asst.Lecturer. Dilveen H. Omar
Erbil Polytechnic University
Technical Engineering College
Civil Engineering Department
This document defines key terms related to road geometrics and cross sections. It discusses the carriageway as the portion for vehicular traffic, road shoulders for emergency use and protecting edges, and formation width as the road embankment width including carriageway and shoulders. It also covers side slopes for embankment/cutting stability, berms between embankments and drains, road margins as land widths with possible inclusions, right of way as acquired land area, and camber and gradients as providing drainage and vehicle regulation.
This document provides guidelines for safer road design in cities. It summarizes traffic fatality rates in various global and Indian cities. It identifies vulnerable road users like children, pedestrians, and two-wheeler riders that account for many deaths in India. Design principles are outlined like shorter block lengths, density near transit, and access to destinations to reduce vehicle travel. Measures to improve safety in Indian cities are proposed like road diets, pedestrian refuge islands, and shared spaces. A collaborative process is recommended involving stakeholders to identify high-risk points and align priorities. Guidelines must be tailored and complemented with audits, policies and community insights for effective implementation of safer city designs.
The document provides an overview of valve and actuator products from a company that has been developing, producing, and selling industrial valves and actuators for over 40 years. It employs around 1,000 people across multiple production locations and subsidiaries globally. The company offers a wide range of valve types, including resilient seated valves, PTFE valves, high performance valves, knife gate valves, and special application valves. It prides itself on outstanding quality and customized solutions through precise coordination of valves, actuators, and automation technology.
The range of JLX bellows seal valves is basically designed to eliminate one of the most serious and frequent problems in steam and thermal fluid installations.
This is the leakage through the gland, that can be the reason of unforeseen maintenance shutdowns, with the consequent cost due to loss of energy.
The document describes an electronic timer-controlled condensate drain called the COMBO. It has an integrated mesh strainer and ball valve to simplify installation. The timer can be adjusted to drain condensate from various compressed air system components at intervals between 0.5 to 45 minutes. It has an IP65 rating and voltage options between 24 to 240 VAC/DC. The unit features a visual display, easy-grip adjusting knobs, and prevents air-locking during drainage.
Terofox provides one stop service in diversity of valves’ procurement and ODM & OEM manufacturing, all our products and quality management procedures are in accordance with ISO 9001. Our wide range of products includes:
API608 Floating Stainless Steel Ball valve
API6D Trunnion Ball valves.
API 594 Dual plate check valves.
Concentric Butterfly Valves (Pins and Pinless / PTFE lining )
But our main focus is our “Special Product Line” in Taiwan that includes:
Sanitary Valves.
Cryogenic Valves: Used in the transmission of extreme low temperature services.
Special Alloy Valves: Some of the Materials we offer are Alloy 20, Monel, Hastelloy, Duplex/ Super Duplex Stainles Steel, Titanium and more.
Dead-man Return Ball Valves: Spring Return Handle that decreases the Torque for easier use.
Fugitive Emission ISO15848-1 certified : Safty is a trend nowadays, our low emission valve meets ISO15848-1 for eliminating fugitive emission
API607 6th Edition / ISO10497:2010 Fire Safe Approval ball valves - Flange Ball valves ( TF-20FS, TF-20DFS ), Trunnion Mounted Ball Valve ( TF-40FS, TF-44FS ) and high performance Ball Valve (EB-321DFS), Wafer Type Ball Valve ( TF-10MFS)
BS6363 Cryogenic Ball Valves
Marine Certified valves
Metal Seated Ball Valves : up to 600 Degree Celsius
3000psi/6000psi/10,000psi Ball Valves
In order to satisfy variety of requirements, we have applied for certificates such as ISO 9001, CE ( PED 97/23/EC ), API607 6th Edition Fire Safe Approved for floating and trunnion mounted ball valve, ABS PDA certificate, TA-Luft, ISO15848 for Fugitive Emmission applications, AD-2000, as well as foundry approvals: DNV, BV, LR certifications.
Our mission is to assist our customers in obtaining the best possible solutions to their requirements and needs, at the most advantageous prices, without compromising on delivery or quality. With this in mind, we believe in developing long terms relationships, based on mutual trust and honesty.
Jual,Harga,Distributor Water Heater Pemanas Air Ariston Toko Jakarta,Bekasi,Tangerang Electrik Harga Murah Ekonomis Bergaransi Cv Fikri Mandiri Jaya 082113812149
The document provides information about various electric water heaters produced by Ariston, including wall-hung models (Europrisma, Piccolo, Eureka), floor standing models (Classico HE, Aquabravo), and a wall-hung unvented cylinder (ST 100). It summarizes the features and specifications of each model, such as tank material and capacity, power rating, dimensions, and typical applications. Installation guidelines and regulations are also discussed.
Det nyeste armatur for pH-, ledningsevne- og iltelektroder. Pneumatisk styret for optimal tilgængelighed af målepunkt og automatisering af kalibrering, rengøring og parkering af elektrode
This document provides information about pipes and fittings produced by aquatechnik, including multi-calor pipes, multi-eco pipes, and polipert pipes. It describes the materials and layers that make up each type of pipe, their specifications, intended uses, dimensions, and certifications. The document also discusses advantages of the pipe systems, installation guidelines, and competence and responsibility of the manufacturer.
Ashcroft produces instruments for measuring pressure, temperature, and flow that are designed for the water treatment and wastewater industries. Their gauges, transmitters, and indicators are made from corrosion-resistant materials like stainless steel and are accurate and durable. Ashcroft also provides documentation to help with engineering and compliance requirements. Customers can find more information on their website or by contacting an Ashcroft expert.
SPC is celebrating 50 years of manufacturing concrete pipes and related products in Southern Africa. They have expanded their product line to include polyethylene pipes obtained through a partnership with an Italian company. The range of PE products includes pipes for water, irrigation, gas, drainage, sewage, and cable ducts. SPC provides technical support for customers and ensures high product quality through experienced personnel and innovative machinery. They aim to offer innovative solutions and prototypes based on market needs.
DMN-WESTINGHOUSE provides components for the bulk solids industry including rotary valves, diverter valves, slide gates, and Morris couplings. They have 5 sales offices and 2 production facilities in Europe and the United States. The document provides an overview of their product lines, applications, designs, materials, and options.
ICON Process Controls specializes in corrosion resistant industrial fluid handling process control equipment, offering industry the most complete line of all plastic instrumentation products supported by the largest inventory in North America. Markets include Municipal and Industrial Water & Waste-Water Treatment, Bulk Chemicals, Steel Processing, Metal Finishing, Chemical Dosing Skids, Food & Beverage.
Stuart Turner Brochure Monsoon - Shower PumpsTaps4Less com
The 2016 Stuart Turner shower pumps catalogue for the Monsoon range. Make you bathroom shower much more powerful. Now in stock at Plumb4Less - http://plumb4less.co.uk/index.php?cPath=242_246_344&osCsid=g8ck0112i6amaq7le1qlp01c95
The ECOTECH Air Sampling System is designed to meet international Standards (including US EPA Quality Assurance Standards) for the continuous sampling of ambient air. Its robust design is suitable for most ambient air gas sampling applications, and all surfaces in contact with the sample air are made with glass or Teflon, including a Teflon raincap which prevents rain entering the shelter.
This document provides information about various high-pressure cleaning products made by Kränzle in Germany. It describes several portable cold water high-pressure cleaners that are compact, lightweight, and suitable for continuous professional use. Models include the HD 7/122 and HD 10/122. It also provides specifications and features of other Kränzle products like the K 1132 small power pack and the K 2000 and Profi series of more powerful cleaners. The document includes ordering numbers, pressure ratings, water outputs, and standard equipment for different models.
COUPLING SYSTEM Quick and Easy Assembly Polypropylene fasteners combine the two main advantages of mechanical fastening systems. Push-fit and clamping: the push-fit process makes it easy to install.
Cartridge check valves (also called non-return valves) are designed for simple installation and offer outstanding performance
inside mating housing. They are valves which only allows water to flow in one direction and prevents backflow.
XHnotion cartridge check valves are not only for water, also for air now. Applications include faucets, showers, valves and
heating systems for residential or commercial installations, as well as pumps,
All the models are 100% tested during production for drip tight operation. Maximum temperature and pressure rating is for
most models 200F(90C)/230psi. The average cracking (opening) pressure of most valves is between 0.25and 0.33 of a psi.
Safe and SterileThe 48 TuBore Series is the Habonim line of clean ball valves for the pharmaceutical and bioprocessing industries. These valves are designed for applications which require maximum flow capacity at minimum pressure drop, where sterility, clean-ability and drain-ability are essential for faultless product quality. The 48 TuBore valve port matches tube ID dimensions, provides tight shutoff and has exceptional performance in many service applications
Integrated features:
Tube bore
Soft parts are FDA approved
Low ferrite
Low sulphur
Outstanding metal surface finish. A fully encapsulated body seal provides an improved seal under fluctuating temperatures and pressures
Stark Builders: Where Quality Meets Craftsmanship!shuilykhatunnil
At Stark Builders our vision is to redefine the renovation experience by combining both stunning design and high quality construction skills. We believe that by delivering both these key aspects together we are able to achieve incredible results for our clients and ensure every project reflects their vision and enhances their lifestyle.
Although we are not all related by blood we have created a team of highly professional and hardworking individuals who share the common goal of delivering beautiful and functional renovated spaces. Our tight nit team are able to work together in a way where we pour our passion into each and every project as we have a love for what we do. Building is our life.
AVRUPA KONUTLARI ESENTEPE - ENGLISH - Listing TurkeyListing Turkey
Looking for a new home in Istanbul? Look no further than Avrupa Konutlari Esentepe! Our beautifully designed homes provide the perfect blend of luxury and comfort, making them the perfect choice for anyone looking for a high-quality home in the city.
With a wide range of apartment types available, from 1+1 to 4+1, we have something to suit every need and budget. Each apartment is designed with attention to detail and features spacious and bright living areas, making them the perfect place to relax and unwind after a long day.
One of the things that sets Avrupa Konutlari Esentepe apart from other developments is our focus on creating a community that is both comfortable and convenient. Our homes are surrounded by lush green spaces, perfect for enjoying a peaceful stroll or having a picnic with friends and family. Additionally, our complex includes a variety of social and recreational amenities, such as swimming pools, sports fields, and playgrounds, making it easy for residents to stay active and socialize with their neighbors.
https://listingturkey.com/property/avrupa-konutlari-esentepe/
Dholera Smart City Latest Development Status 2024.pdfShivgan Infratech
Explore the latest development status of Dholera Smart City in 2024. Discover the progress, infrastructure, and future plans of India's first greenfield smart city.
Serviced Apartment Ho Chi Minh For RentalGVRenting
GVRenting is the leading rental real estate company in Vietnam. We help you to find a serviced apartment for rent in Ho Chi Minh & Saigon. Discover our broad range of rental properties in Vietnam.
For more details https://gvrenting.com/
The SVN® organization shares a portion of their new weekly listings via their SVN Live® Weekly Property Broadcast. Visit https://svn.com/svn-live/ if you would like to attend our weekly call, which we open up to the brokerage community.
BEST FARMLAND FOR SALE | FARM PLOTS NEAR BANGALORE | KANAKAPURA | CHICKKABALP...knox groups real estate
welcome to knox groups real estate company in Bangalore. best farm land for sale near Bangalore and madhugiri . Managed farmland near Kanakapura and Chickkabalapur get know more details about the projects .Knox groups is a leading real estate company dedicated to helping individuals and businesses navigate the dynamic real estate market. With our extensive knowledge, experience, and commitment to excellence, we deliver exceptional results for our clients. Discover the perfect foundation for your agricultural aspirations with KNOX Groups' prime farm lands. These aren't just plots; they're the fertile grounds where vibrant crops flourish, livestock thrives, and unique agricultural ventures come to life. At KNOX, we go beyond selling land we curate sustainable ecosystems, ensuring that your journey toward agricultural success is seamless and prosperous.
Recent Trends Fueling The Surge in Farmhouse Demand in IndiaFarmland Bazaar
Embarking on the journey to acquire a farmhouse for sale is just the beginning; the real investment lies in crafting an environment that contributes to our mental and physical well-being while satisfying the soul. At Farmlandbazaar.com, India’s leading online marketplace dedicated to farm land, farmhouses, and agricultural lands, we understand the importance of transforming a humble farmland into a warm and inviting sanctuary. Let's explore the fundamental aspects that can elevate your farmhouse into a tranquil haven.
4. COMPANY
PROFILE
As Visam A.S., we are established in 1964 as the first Flushing Mechanisms and Plastic Cistern manufacturer
in Turkey. We have left behind a Half-Century with our quality focused production, honest sales policy and after
sales services that makes us the oldest and the best company in its field in Turkey. We are providing the market
for quality yet affordable products that we produce with an experience of long years in the sector. We also focus
highly on our after sale services and availability of spare parts for a complete and flawless customer
satisfaction. Our constantly growing range of different products manufactured with the latest technology still
enables us to be the "Trusted Brand" in our field.
Visam A.S. manages Quality Control and R&D processes with an 8 person team according to the TS EN ISO
9001:2008 Quality Management System regulation. As a result of our quality horizon (European Norms), best
raw materials are selected before production. We care about sustainable production at the same time producing
Environment Friendly products, consequently we are reliable to TS EN ISO 14001:2004 Environmental
Management System. We are also a member of TUKCEV for recycling and sustainable environment. After these
selection and production processes, semi-products evolves to end-products in the hands of our employees,
most of them we work from long years. We care about experienced work power and want to work with our
employees as long as we can. We try to provide their work health and safety and managing these processes
with OHSAS 18001:2007 Occupational Health and Safety Management System regulation. We have our own
laboratory that we can run the tests according to European Norms. We run the tests which are necessary to
maintain a quality product such as lifetime cycles, durability, chemical tests, efficiency etc.
6. Water efficient Easy maintenance Easy installation Endurance up to 400 kg
Hygienic Silent Space saver
Visam concealed cisterns are continuously tested
according to related EN standards in our laboratory.
In order to maintain the quality below tests are applied.
Overflow Test
Weight Test (Endurance Up To 400 Kg)
Leak Tightness Test
Flow Rate Test
Hydraulic and Mechanical Performance Test
Life Time Cycle (Reliability) Test
SINC
E 1964
9. 7
Slim 80 Series
110-001 For Wall Hung WC Pans
Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPROPRIATE FOR BRICK WALL INSTALLATION
TECHNICAL DETAILS
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 80 mm
Mechanical Dual Flush
Water supply connec�on top right G 1/2 Male
Acous�c Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 9.0 dB, Flow rate : 9 L/min
Impact Copolymer special PP Body. (High resistance to impact and thermal shock)
Styropor insula�on in front ofthe body for a be�er acous�c level and to prevent condensation.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm (axial distance oftoilet
bowls).
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connec�on clamp, elbow and stopper.
Connec�on parts for mounting toilet bowl
Parts that will be necessary for installation and connec�on.
< 9.0dB
11. 9
Slim 80 Series
111-001 For Squatting & Floor Mounted
WC Pans –Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPROPRIATE FOR BRICK WALL INSTALLATION
TECHNICAL DETAILS
Suitable to Floor Mounted Pans and Squatting Pans both
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 80 mm
Mechanical Dual Flush
Water supply connec�on top right G 1/2 Male
Acous�c Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 9.0 dB, Flow rate : 9 L/min
Impact Copolymer special PP Body. (High resistance to impact and thermal shock)
Styropor insula�on in front ofthe body for a be�er acous�c level and to
prevent condensa�on.
BOX CONTENTS
Angle Valve DN 15 1/2
Parts that will be necessary for installation and connec�on.
< 9.0dB
9
13. 11
Slim 80 Series
112-001 For Dry Walls –Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPROPRIATE FOR DRY WALL INSTALLATION &
BRICK WALL INSTALLATION
TECHNICAL DETAILS
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 80 mm (Overall thickness including frame 90 mm)
Mechanical Dual Flush
Water supply connec�on top right G 1/2 Male
Acous�c Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 9.0 dB, Flow rate : 9 L/min
Impact Copolymer special PP Body. (High resistance to impact and thermal shock)
Styropor insula�on wrapped body for a be�er acous�c level and to prevent condensation
Powder coated, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. (Adjustable for 18 or 23 cm (axial distance
oftoilet bowls).
BOX CONTENTS
Suppor�ng frame and height adjustable galvanised support legs
Depth adjustable galvanised brackets for pre-wall installa�on
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Connec�on parts for mounting toilet bowl
Parts that will be necessary for installation and connec�on.
< 9.0dB
15. 13
Slim 80 Series
112-002 Free Standing –Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPROPRIATE FOR DRY WALL INSTALLATION
TECHNICAL DETAILS
Easy installation, i�s fixed to the floor only. (Frame can stand free
withou�ixa�on from the back)
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 80 mm (Overall thickness including frame 90 mm)
Manual Dual Flush
Water supply connec�on top right G 1/2 Male
Acous�c Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 9.0 dB, Flow rate : 9 L/min
Impact Copolymer special PP Body. (High resistance to impact and thermal shock)
Styropor insula�on wrapped body for a be�er acous�c level and to prevent condensation
Powder coated, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm (axial distance oftoilet
bowls)
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connec�on clamp, elbow and stopper.
Connec�on parts for mounting toilet bowl
Parts that will be necessary for installation and connec�on.
< 9.0dB
17. 15
Slim 80 Series
113-001 Back to Back Application
Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPROPRIATE FOR DRY WALL INSTALLATION
TECHNICAL DETAILS
Easy installation, i�s fixed to the floor only.
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 80 mm (Overall thickness including frame 240 mm)
Mechanical Dual Flush
Water supply connec�on top right G 1/2 Male
Acous�c Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 9.0 dB, Flow rate : 9 L/min
Impact Copolymer special PP Body. (High resistance to impact and thermal shock)
Styropor insula�on wrapped body for a be�er acous�c level and to prevent condensation
Powder coated, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm (axial distance oftoilet
bowls).
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connec�on clamp, elbow and stopper.
Connec�on parts for mounting toilet bowl
Parts that will be necessary for installation and connec�on.
< 9.0dB
19. Norm 120 Series
130-001 For Wall Hung WC Pans
Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 4/7 L
APPROPRIATE FOR BRICK WALL INSTALLATION
TECHNICAL DETAILS
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 120 mm
Mechanical Dual Flush
Water supply connection top right G 1/2 Male
Acoustic Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 13.0 dB, Flow rate : 9 L/min
High resistant ABS body
Styropor insulation wraps the body for a better acoustic level and to prevent
condensation.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm (axial distance of
toilet bowls).
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connection clamp, elbow and stopper.
Connection parts for mounting toilet bowl
Parts that will be necessary for installation and connection.
17
21. Norm 120 Series
131-001 For Squatting &
Floor Mounted WC Pans – Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 4/7 L
APPROPRIATE FOR BRICK WALL INSTALLATION
TECHNICAL DETAILS
Suitable to Floor Mounted Pans and Squatting Pans both
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 120 mm
Mechanical Dual Flush
Water supply connection top right G 1/2 Male
Acoustic Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 13.0 dB, Flow rate : 9 L/min
High resistant ABS body
Styropor insulation wraps the body for a better acoustic level and to
prevent condensation.
BOX CONTENTS
Angle Valve DN 15 1/2
Parts that will be necessary for installation and connection.
19
23. Norm 120 Series
132-001 For Dry Walls – Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 4/7 L
APPROPRIATE FOR DRY WALL INSTALLATION &
BRICK WALL INSTALLATION
TECHNICAL DETAILS
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 120 mm (Overall thickness including frame 140 mm)
Mechanical Dual Flush
Water supply connection top right G 1/2 Male
Acoustic Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 13.0 dB, Flow rate : 9 L/min
High resistant ABS body
Styropor insulation wraps body for a better acoustic level and to prevent
condensation
Powder coated, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm (axial distance of
toilet bowls).
BOX CONTENTS
Supporting frame and height adjustable galvanised support legs
Depth adjustable galvanised brackets for pre-wall installation
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Connection parts for mounting toilet bowl
Parts that will be necessary for installation and connection.
21
25. Norm 120 Series
132-003 Free Standing – Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 4/7 L
APPROPRIATE FOR DRY WALL INSTALLATION
TECHNICAL DETAILS
Easy installation, it is fixed to the floor only. (Frame can stand free
without fixation from the back)
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 120 mm (Overall thickness including frame 140 mm)
Mechanical Dual Flush
Water supply connection top right G 1/2 Male
Acoustic Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 13.0 dB, Flow rate : 9 L/min
High resistant ABS body
Styropor insulation wraps body for a better acoustic level and to prevent condensation
Powder coated, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm
(axial distance of toilet bowls).
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connection clamp, elbow and stopper.
Connection parts for mounting toilet bowl
Parts that will be necessary for installation and connection.
23
27. Norm 120 Series
133-001 Back to Back Application
Dual Flush
COMPATIBLE STANDARD
EN 14055 CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 4/7 L
APPROPRIATE FOR DRY WALL INSTALLATION
TECHNICAL DETAILS
Easy installation, it is fixed to the floor only.
Completely preassembled in the factory
Water tank capacity 10 L max
Tank depth 120 mm (Overall thickness including frame 280 mm)
Mechanical Dual Flush
Water supply connection top right G 1/2 Male
Acoustic Class (1st Class) EN 14124 Inlet Valve
Water flow pressure 0.3 MPa (3 bar) / Max Vol : 13.0 dB, Flow rate : 9 L/min
High resistant ABS body
Styropor insulation wraps body for a better acoustic level and to prevent condensation
Powder coating, tubing profile thick (30mmx40mm) metal frame.
WC hanging rods can bear up to 400 kgs. Adjustable for 18 or 23 cm
(axial distance of toilet bowls).
BOX CONTENTS
Height adjustable galvanised support legs
Angle Valve DN 15 1/2
PE Soil Pipe Connector (Ø 90/90mm – including 110mm adapter)
Concealed stop valve connection clamp, elbow and stopper.
Connection parts for mounting toilet bowl
Parts that will be necessary for installation and connection.
25
31. 29
Flush Plates are produced and stocked in matt chrome,
bright chrome and white colors. They can be produced in
various colors upon request.
Milet
Dual Flush
code: 224-001 code: 224-003
code: 224-002
matt chrome white
bright chrome
Karina
Dual Flush
matt chrome white
code: 226-001 code: 226-003
code: 226-002
bright chrome
Didim
Dual Flush
matt chrome white
code: 223-001 code: 223-003
code: 223-002
bright chrome
F lush Plates
226 mm
165mm
11 mm
new
32. Flush Plates are produced and stocked in matt chrome,
bright chrome and white colors. They can be produced in
various colors upon request.
Efes
Dual Flush
Agora
Dual Flush
Artemis
Dual Flush
matt chrome
code: 220-001
code: 221-001
code: 222-001
code: 220-003
code: 221-003
code: 222-003
code: 220-002
code: 221-002
code: 222-002
matt chrome
matt chrome
white
white
white
bright chrome
bright chrome
bright chrome
Perge
Dual Flush
code: 225-001
matt chrome
code: 225-003
white
code: 225-002
bright chrome
F lush Plates
30
33. Flush Plates are produced and stocked in matt chrome,
bright chrome and white colors. They can be produced in
various colors upon request.
Interruptible Flush Plates
Bigger Flush Plates
200-002
200-001
200-003
EFES
FONTANA
PRESTİJ
DUAL FLUSH
202-001
202-002 202-003
ARTEMİS
201-001
201-002 201-003
AGORA
*Can be used for only Norm 120 Series
matt chrome
matt chrome
matt chrome
bright chrome
bright chrome
bright chrome
white
white
white
code: 261-001
code: 260-001
code: 250-001
code: 250-002
code: 250-003
code: 260-002
code: 260-003
code: 261-002
code: 261-003
F lush Plates
31
34. 32
On-Off Ceramic Headwork
1/2 Plas�c Body
On-Off Ceramic Headwork
3/4 Plas�c Body
On-Off Ceramic Headwork
1/2 Plas�c Body
On-Off Ceramic Headwork
3/4 Plas�c Body
On-Off Ceramic Headwork
1/2 Plas�c Body
On-Off Ceramic Headwork
3/4 Plas�c Body
37. Exposed Plastic Cisterns
400-001 Alfa Interruptible
402-001 Alfa Dual Flush
405-001 Beta Interruptible
407-001 Beta Dual Flush
COMPATIBLE STANDARD
EN 14055 - CL 1 - 6 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPLICATION
For low level installation bottom inlet
TECHNICAL DETAILS
Water tank capacity 9 L max
Mechanical Dual Flush (or Interruptible), you can save water up to 60%
Water supply connection from bottom G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
Flexible discharge pipe option
COMPATIBLE STANDARD
EN 14055 - CL 1 - 6 - NL I - VR II
DISCHARGE VOLUME 3/6 L
APPLICATION
For low level installation side inlet
TECHNICAL DETAILS
Water tank capacity 9 L max
Mechanical Dual Flush (or Interruptible), you can save water up to 60%
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
interruptible
interruptible
dual flush
dual flush
35
38. Exposed Plastic Cisterns
410-001 Nil
Interruptible
411-001 Gönye
DISCHARGE VOLUME 7 L
APPLICATION For low level installation
TECHNICAL DETAILS
Water tank capacity 9 L max
Styropor insulation inside the body for a better acoustic level and to prevent
condensation.
Mechanical Interruptible operation, you can save water up to 60%
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special ABS Body
Discharge group is preassembled in the factory, elobw discharge pipe is included to box
DISCHARGE VOLUME 7 L
APPLICATION For low level CORNER installation
TECHNICAL DETAILS
Water tank capacity 10 L max
Mechanical flush
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
Option for styropor insulation inside the body (for a better acoustic level and to prevent
condensation)
36
39. 37
Exposed Plastic Cisterns
413-001 Deniz 2000
Interruptible
413-005 Deniz 2000
Interruptible With
Styropor Insulation
COMPATIBLE STANDARD
EN 14055 - CL 1 - 9 - NL I - VR II
DISCHARGE VOLUME 9 L
APPLICATION For low level installation
TECHNICAL DETAILS
Water tank capacity 12 L max
Mechanical interruptible operation, you can save water up to 60%
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
COMPATIBLE STANDARD
EN 14055 - CL 1 - 7 - NL I - VR II
DISCHARGE VOLUME 7 L
APPLICATION For low level installation
TECHNICAL DETAILS
Water tank capacity 10 L max
Styropor insulation inside the body for a better acoustic level and to prevent
condensation.
Mechanical interruptible operation, you can save water up to 60%
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
Flexible discharge pipe option
40. Exposed Plastic Cisterns
415-001 Deniz Pneumatic
Dual Flush
450-001 Lord 2000
DISCHARGE VOLUME 4/9 L
APPLICATION For low level installation
TECHNICAL DETAILS
Water tank capacity 12 L max
Pneumatic dual flush operation, you can save water up to 60%
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, elbow discharge pipe is included to box
Flexible discharge pipe option
COMPATIBLE STANDARD
EN 14055 - CL 1 - 6 - NL I - VR II
DISCHARGE VOLUME 6 L
APPLICATION For high level installation
TECHNICAL DETAILS
Water tank capacity 8 L max
Water supply connection from left or right G 1/2 (plastic)
Acoustic Class (1st Class) EN 14124 Inlet Valve
High resistant special PP Body
Discharge group is preassembled in the factory, discharge pipe is not included to box
38
43. 41
TECHNICAL DETAILS
512-001 Açelya Soft Close
TECHNICAL DETAILS
513-001 Begonya Soft Close
Duroplast Soft Close Toilet Seats
TECHNICAL DETAILS
530-001 Akasya Soft Close
TECHNICAL DETAILS
531-001 Kamelya Soft Close
450mm
360 mm
277mm
213 mm
438mm
340 mm
275mm
220 mm
360 mm
433mm
444mm
380 mm
An�bacterial and impact resistant UREA raw material
Soft closing mechanism
S.S. hinges for soft close dampers
Easy installa�on and easy release
2.250 g (without hinges)
An�bacterial and impact resistant UREA raw material
Soft closing mechanism
S.S. hinges for soft close dampers
Easy installa�on and easy release
2.050 g (without hinges)
An�bacterial and impact resistant UREA raw material
Soft closing mechanism
S.S. hinges for soft close dampers
Easy installa�on and easy release
2.075 g (without hinges)
An�bacterial and impact resistant UREA raw material
Soft closing mechanism
S.S. hinges for soft close dampers
Easy installa�on and easy release
1.900 g (without hinges)
230 mm
288mm
360 mm
446mm
448mm
360 mm
448mm
360 mm
446mm
270mm
360 mm
226 mm
new
new
45. 43
TECHNICAL DETAILS
Antibacterial and impact resistant UREA raw material
Plastic or S.S. Hinges option
1550 g (without hinges)
501-001 Sardunya
446mm
384 mm
231 mm
285mm
367 mm
440mm
TECHNICAL DETAILS
Antibacterial and impact resistant UREA raw material
Plastic or S.S. Hinges option
1300 g (without hinges)
503-001 Lavanta
Duroplast Toilet Seats
440mm
231 mm
285mm
367 mm330 mm
424mm
TECHNICAL DETAILS
Antibacterial and impact resistant UREA raw material
Plastic or S.S. Hinges option
1910 g (without hinges)
505-001 Ege
453mm
225 mm
360 mm
292mm
460mm
360 mm
TECHNICAL DETAILS
Antibacterial and impact resistant UREA raw material
Plastic or S.S. Hinges option
1910 g (without hinges)
508-001 Klasik
367 mm
230 mm
440mm
285mm
367 mm
450mm
* color / pattern options
46. 44
440mm
445mm
378 mm
230 mm
286mm
366 mm
Thermoplast Toilet Seats
TECHNICAL DETAILS
Premium PP raw material
Impact resistant
665 gr (without hinges)
520-001 Narin
365 mm
438mm
285mm
220 mm
445mm
370 mm
TECHNICAL DETAILS
Premium PP raw material
Impact resistant
995 gr (without hinges)
523-001 Orkide
TECHNICAL DETAILS
Premium PP raw material
Impact resistant
854 gr (without hinges)
525-001 İris
TECHNICAL DETAILS
Premium PP raw material
Impact resistant
1052 gr (without hinges)
528-001 Melisa
445mm
365 mm
300mm
230 mm
445mm
365 mm
371 mm
442mm
276mm
234 mm
436mm
362 mm
521-001 Nilufer 522-001 Lale
49. 47
Inlet Valves
650-001 Zeplin Inlet Valve 3/8 651-001 Roket Inlet Valve 3/8
652-001 Jet Inlet Valve 3/8
652-002 Jet Inlet Valve 1/2
654-001 Cosmos Inlet Valve 3/8
654-002 Cosmos Inlet Valve 1/2
COMPATIBLE STANDARD EN 14124 (1st Class)
TECHNICAL DETAILS
Bottom inlet
Adjustable height
Silent (10,3 dB / 5 bar)
Water supply connection G 3/8 (brass)
Can be applied in tight cisterns
Suitable to all ceramic cisterns
Can be used both high and low water
pressure (0,5 – 10 bar)
COMPATIBLE STANDARD EN 14124 (1st Class)
TECHNICAL DETAILS
Bottom inlet
Adjustable height
Silent (11,8 dB / 5 bar)
Water supply connection G 3/8 (brass)
Can be applied in tight cisterns
Instant shutting
Suitable to all ceramic cisterns
Can be used both high and low water
pressure (0,5 – 10 bar)
COMPATIBLE STANDARD EN 14124 (1st Class)
TECHNICAL DETAILS
Side inlet
Adjustable height
Can be used both high and low water pressure (0,5 – 10 bar)
Silent (13,0 dB / 3 bar)
Water supply connection G 3/8 (brass) or G 1/2 (plastic)
Instant shutting
COMPATIBLE STANDARD EN 14055 (1st Class)
TECHNICAL DETAILS
Side inlet
Adjustable height
Compact design
Can be used both high and low water pressure (0,5 – 10 bar)
Silent (9 dB / 3 bar)
Water supply connection G 3/8 (brass) or G 1/2 (plastic)
1/2
1/2
3/8
3/8
50. 48
Flushing Mechanisms / Pull Systems
601-001 Starmax
603-001 Star
604-001 Klasik
Interruptible Pull System
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
Pull system
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
Pull system with flapper
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
*Option for ECO models with ZEPLİN (EN 14124 - 1st Class) Inlet Valve
51. 49
Flushing Mechanisms / Push Systems
602-001 Jumbo
605-001 Atlas
606-001 Truva
Push system
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
Pneumatic Push System
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
Water saving dual flush pneumatic push system
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Roket Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
*Option for ECO models with ZEPLİN (EN 14124 - 1st Class) Inlet Valve
52. 50
Flushing Mechanisms / Push Systems
607-001 Assos
614-001 Teos
Water saving Dual flush push system
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Zeplin Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
Push system
Fast and easy installation
Suitable for 16mm and 40mm lid holes
Included silent Zeplin Inlet Valve (EN 14124 – 1st class)
Water supply connection G 3/8 (brass)
55. 53
Shower Drains
Linear Shower Drains (S.S. Grate & S.S. Case)
Eco Linear Shower Drains (S.S. Grate & Plastic Case)
Item Code Outlet Direction Grate Size ( a x 67 mm ) Grate Material Height Special FeatureOutlet Dia
764-001 Horizontal 200x67mm Slot AISI304 71mm Water Block for Odor
764-002 Horizontal 300x67mm Slot AISI304 71mm Water Block for Odor
764-003 Horizontal 400x67mm Slot AISI304 71mm Water Block for Odor
764-004 Horizontal 500x67mm Slot AISI304 71mm Water Block for Odor
764-005 Horizontal 650x67mm Slot AISI304 71mm Water Block for Odor
764-006 Horizontal 800x67mm Slot AISI304 71mm Water Block for Odor
765-001 Horizontal 200x67mm Plain AISI304 71mm Water Block for Odor
765-002 Horizontal 300x67mm Plain AISI304 71mm Water Block for Odor
765-003 Horizontal 400x67mm Plain AISI304 71mm Water Block for Odor
765-004 Horizontal 500x67mm Plain AISI304 71mm Water Block for Odor
765-005 Horizontal 650x67mm Plain AISI304 71mm Water Block for Odor
Water Block for Odor765-006 Horizontal 800x67mm Plain AISI304 71mm
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Item Code Outlet Direction Grate Size ( a x 65 mm ) Grate Material Height Special FeatureOutlet Dia
766-001 200x65mm Slot AISI304 71mm Water Block for Odor
766-002 300x65mm Slot AISI304 71mm Water Block for Odor
766-003
766-004
766-005
400x65mm
500x65mm
500x65mm
600x65mm
600x65mm
Slot AISI304
Slot AISI304
Slot AISI304
71mm
71mm
71mm
Water Block for Odor
Water Block for Odor
Water Block for Odor
767-001 200x65mm Plain AISI304 71mm Water Block for Odor
767-002 300x65mm Plain AISI304 71mm Water Block for Odor
767-003
767-004
767-005
400x65mm Plain AISI304
Plain AISI304
Plain AISI304
71mm
71mm
71mm
Water Block for Odor
Water Block for Odor
Water Block for Odor
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Horizontal (360°)
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
Ø50
56. 54
Floor Drains
Stainless Steel Grate, Rotating Cap Floor Drains
Classic Polypropylene Floor Drains
750-001
750-002**
751-001
751-002**
752-001
752-002**
753-001
753-002**
755-001
755-002**
757-001
758-001
759-001
760-001
761-001
762-001
763-001
Horizontal
Horizontal
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
100x100 mm
150x150 mm
150x150 mm
150x150 mm
150x150 mm
150x150 mm
65mm
65mm
45mm
45mm
65mm
65mm
45mm
45mm
45mm
45mm
55mm (adj*)
110mm (adj*)
55mm (adj*)
110mm (adj*)
84mm (adj*)
110mm (adj*)
110mm (adj*)
PP
PP
PP
PP
S.S.(AISI304)
S.S.(AISI304)
S.S.(AISI304)
S.S.(AISI304)
S.S.(AISI304)
S.S.(AISI304)
PP
PP
PP
PP
PP
PP
PP
Water Block for Odor
Water Block for Odor
Mechanical Odor Block
Mechanical Odor Block
Water Block for Odor
Water Block for Odor
Water Block for Odor
Water Block for Odor
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
Mechanical Odor Block
* adj : adjustable
** Marked items are produced as Eco models. Grate thickness are reduced to 0,5mm from 1mm and 1,2mm and the material is still AISI304.
Item Code Outlet Direction Grate Size ( a x a mm ) Height (h) Frame Special FeatureOutlet Dia (d)
729-001
730-001
725-001
726-001
727-001
728-001
731-001
732-001
756-001
Horizontal
Horizontal
Horizontal
Horizontal
Vertical
Vertical
Vertical
Horizontal
Horizontal
150x150 mm
100x100 mm
150x150 mm
100x100 mm
150x150 mm
100x100 mm
150x150 mm
150x150 mm
100x100 mm
70mm
70mm
70mm
70mm
45mm
45mm
55mm
100mm
45mm
Water Block for Odor
Water Block for Odor
Water Block for Odor
Water Block for Odor
Water Block for Odor
Water Block for Odor
With Waste Duct
With Waste Duct
Water Block for Odor
Ø 50
Ø 50
Ø 50
Ø 50
Ø 50
Ø 50
Ø 70 / Ø 100
Ø 70
Ø 32
Item Code Outlet Direction Grate Size ( a x a mm ) Height (h) Special FeatureOutlet Dia (d)
61. 59
891-005 Aspendos 3-Way
Bath Mixer
Built-in Bath M ixers
Overhead Shower, Hand Shower and Spout included.
PPRC raw material body.
3 Way rotary diverter.
Easy connec�on to PPRC pipe without any additional fit�ngs.
Economical usage with aerator.
FEATURES
891-003 Patara 3-Way
Bath Mixer
Overhead Shower, Hand Shower and Spout included.
PPRC raw material body.
3 Way Push/Pull diverter.
Easy connec�on to PPRC pipe without any additional fit�ngs.
Economical usage with aerator.
FEATURES
891-001 Likya Bath Mixer
Hand Shower and Spout included.
PPRC raw material body.
Pull diverter.
Easy connec�on to PPRC pipe without any additional fit�ngs.
Economical usage with aerator.
FEATURES
new
new
new
62. Built-in Shower M ixers
891-004 Olimpos 2-Way Shower Mixer
Overhead Shower and Hand Shower included.
PPRC raw material body.
2 Way rotary diverter.
Easy connec�on to PPRC pipe without any additional fit�ngs.
FEATURES
891-002 Side Shower Mixer
Overhead Shower included.
PPRC raw material body.
Easy connec�on to PPRC pipe without any additional fit�ngs.
FEATURES
new
new
60