This document summarizes the network configuration of the Second Hospital of Traditional Chinese Medicine in Luoyang. It includes the contact information, equipment list, core network topology diagram with IP addresses, remote management methods of network devices, important VRRP and multi-instance STP configurations, as well as IP address and port planning tables.
The document is a user manual for the GreyRapid N Wireless Network Router. It provides an introduction to the router and its features, which include allowing multiple computers and network devices to share a single internet connection via Ethernet ports or wireless connectivity. It also lists the contents of the manual, which covers topics like system setup, configuration of wired and wireless networks, advanced functions such as quality of service, security, and troubleshooting. The manual is intended to guide users through installing and using the router to set up a home or small office network.
This document provides specifications for auxiliary AC/DC panels intended for use in Saudi Electricity Company's primary distribution substations. It outlines requirements for the design, construction, components, and testing of the panels. Key requirements include compliance with relevant codes and standards, ratings for AC and DC voltages, enclosure specifications, circuit breaker types and ratings, and testing procedures. The panels are to house components like circuit breakers, busbars, relays, meters and instruments for control and protection of primary substation equipment.
This document provides specifications for annunciator systems used in Saudi Electricity Company's primary distribution substations. It outlines requirements for the design, construction, testing and components of the annunciator system. This includes specifications for the alarm logic unit, visual display unit, control buttons, audible devices, alarm lists and power supply. The annunciator system must comply with industry standards and codes, provide modular expandability, and clearly display alarm information.
This document is the user guide for the MSI-6260 Trans-Weigh crane scale system. It contains information on installation, operation, calibration, troubleshooting and specifications for the crane unit and indicator unit. The table of contents outlines the various sections and topics covered in the user guide.
Be ready for high density power distribution challenges with the ePanel-HD2 High Density Remote Power Panel. Designed and quality manufactured by LayerZero Power Systems in Aurora, Ohio USA.
This document provides installation instructions for the AP-8222 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall or ceiling mounting, connecting the power injector system, and basic configuration of the access point. The document also provides specifications, regulatory information, and support contact details for the AP-8222.
VDSL Home Gateway Router - Copyright, all rights reserved.David_Tickner
This document provides a user guide for a VDSL2 Gateway with wireless capabilities. It includes instructions for installation, configuration, network planning considerations, and using the web interface to view status information and configure system settings. Compliance certifications are listed, as well as warnings and environmental details.
This document provides specifications for the ESP32 family of Wi-Fi and Bluetooth combo chips. It includes information on the chip's features such as integrated Wi-Fi and Bluetooth radios, dual-core CPUs, various peripherals, and low power modes. Revision histories and information on ordering parts are also included.
The document is a user manual for the GreyRapid N Wireless Network Router. It provides an introduction to the router and its features, which include allowing multiple computers and network devices to share a single internet connection via Ethernet ports or wireless connectivity. It also lists the contents of the manual, which covers topics like system setup, configuration of wired and wireless networks, advanced functions such as quality of service, security, and troubleshooting. The manual is intended to guide users through installing and using the router to set up a home or small office network.
This document provides specifications for auxiliary AC/DC panels intended for use in Saudi Electricity Company's primary distribution substations. It outlines requirements for the design, construction, components, and testing of the panels. Key requirements include compliance with relevant codes and standards, ratings for AC and DC voltages, enclosure specifications, circuit breaker types and ratings, and testing procedures. The panels are to house components like circuit breakers, busbars, relays, meters and instruments for control and protection of primary substation equipment.
This document provides specifications for annunciator systems used in Saudi Electricity Company's primary distribution substations. It outlines requirements for the design, construction, testing and components of the annunciator system. This includes specifications for the alarm logic unit, visual display unit, control buttons, audible devices, alarm lists and power supply. The annunciator system must comply with industry standards and codes, provide modular expandability, and clearly display alarm information.
This document is the user guide for the MSI-6260 Trans-Weigh crane scale system. It contains information on installation, operation, calibration, troubleshooting and specifications for the crane unit and indicator unit. The table of contents outlines the various sections and topics covered in the user guide.
Be ready for high density power distribution challenges with the ePanel-HD2 High Density Remote Power Panel. Designed and quality manufactured by LayerZero Power Systems in Aurora, Ohio USA.
This document provides installation instructions for the AP-8222 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall or ceiling mounting, connecting the power injector system, and basic configuration of the access point. The document also provides specifications, regulatory information, and support contact details for the AP-8222.
VDSL Home Gateway Router - Copyright, all rights reserved.David_Tickner
This document provides a user guide for a VDSL2 Gateway with wireless capabilities. It includes instructions for installation, configuration, network planning considerations, and using the web interface to view status information and configure system settings. Compliance certifications are listed, as well as warnings and environmental details.
This document provides specifications for the ESP32 family of Wi-Fi and Bluetooth combo chips. It includes information on the chip's features such as integrated Wi-Fi and Bluetooth radios, dual-core CPUs, various peripherals, and low power modes. Revision histories and information on ordering parts are also included.
This document provides instructions for installing an outdoor pool and spa system. It discusses:
- Having a qualified electrician install the electrical components according to code
- Connecting the system to a dedicated circuit protected by a GFCI
- Connecting components such as pumps, blowers, and lights to color-coded receptacles
- Configuring universal circuits for 120V or 240V operation
- Installing the control panel and temperature sensor
- Connecting a gas heater according to the manufacturer's instructions
- Bypassing pressure or flow switches if needed
- Adjusting the pressure switch if issues arise related to water flow
The document provides an overview and instructions for configuring and using the Danfoss Ethernet Master gateway. The Ethernet Master allows communication between Danfoss VLT frequency drives on an FC-bus network and an Ethernet network, enabling control and monitoring of the drives from a PLC or HMI. Key features include: connecting up to 16 drives; IP address configuration via DIP switches, ARP command, or Netbiter tool; monitoring drives via built-in web server; and memory mapping for control/status data exchange with drives.
The document provides troubleshooting guidance for common issues with wireless switches, including: switch boot up problems, IP address assignment via DHCP, connectivity issues using Telnet/SSH, slow or unresponsive web interface, faulty console port, VLAN configuration loss after reboot, access port adoption failures, mobile unit association problems, failover malfunctions, version number changes after upgrades, excessive network traffic, and memory leaks. It also describes the system status LEDs and logging mechanism to help diagnose issues.
This document provides information about TNC connectors made by CMPTER Electronics, including:
- Technical specifications for TNC connectors including impedance, frequency range, and environmental tolerances
- Interface dimensions and tolerances for TNC connectors compliant with international standards
- Pictures and part numbers for various TNC cable connectors and receptacles with details on assembly instructions
This document provides installation instructions for the Motorola RFS7000 Series RF Switch. It describes the physical specifications, power requirements, port connections including Ethernet, USB, and console ports, as well as instructions for rack mounting and powering on the device. LED codes and patterns are explained to verify proper installation and operation.
The document provides installation instructions for the Motorola RFS6000 Series RF Switch. It includes specifications for the switch, descriptions of the LED codes on the front panel, and step-by-step instructions for hardware setup including cabling, rack mounting, connecting power and verifying installation. The introduction describes the purpose of the switch in centralizing wireless LAN configuration and management.
The LayerZero Series 70: eRDP-FS is a Remote Distribution Panel. Equipped with a built-in touch screen panel, eRDP-FS captures essential power quality information, including real-time waveform capture.
Designed and manufactured by LayerZero Power Systems in Aurora, Ohio USA.
This document provides instructions for installing and configuring an ADSL2+ modem. It includes sections on hardware installation, connecting to the internet, configuring local network and DHCP server settings, checking status, resetting to default settings, and specifications. The document contains diagrams of the modem hardware and definitions of acronyms used.
- IPv6 EIGRP requires enabling IPv6 unicast routing and configuring a router ID before EIGRP can function. The ipv6 eigrp interface command must be used on all participating interfaces instead of the network command.
- Neighbor relationships form when interfaces are configured and hello packets are exchanged. Show commands display neighbor, protocol, and route information for troubleshooting. Summarization and redistribution can be used to manipulate route advertisements between routers.
This document describes the RFM73 2.4GHz transceiver chip, including its features, modes of operation, packet processing, and register interface. The chip operates in the 2.4GHz ISM band and supports data rates up to 2Mbps. It has a SPI interface and integrated packet handling for low-power wireless applications such as mice, keyboards, and remote controls.
The document is the installation and user guide for the DN100 Outdoor Wireless Intelligent Access Point. It provides instructions on planning, installing, and configuring the DN100 for use as a wireless access point or wireless backhaul link. The guide covers topics such as radio frequency planning, antenna installation, Ethernet cabling, power supply, and initial configuration of the device's network settings and security. It also includes the DN100 specifications, limited warranty information, and contact details for technical support.
Electric Control Valve Actuators for Industrial Process ApplicationsCTi Controltech
The Rotork CVA line of electric process control actuators offers a highly accurate and responsive method of automating control valves, without the complexity and cost of a pneumatic supply. With an increased focus on production costs and efficiency, accurate control of product through the pipeline is paramount. With resolution figures better than 0.1% and the ability to eliminate position overshoot, the Rotork CVA models help to maximize product quality and plant capacity.
This document provides guidance on selecting and installing surge protection devices (SPDs) for process control systems to protect sensitive electronics from electrical surges. It discusses SPD placement for different applications including hazardous areas, analog and digital I/O, high current signals up to 6A, 4-20mA loops, interposing relays, RTDs, HART communication, and RS232/RS485. SPDs should be installed at both ends of cable runs connecting PLCs, field instruments, and I/O to provide adequate protection from surges traveling on cables.
The document provides information on various headend equipment from PDT Ltd including modulators, demodulators, combiners, and accessories. Key products described include:
- The 19 inch Audio/Video Modulator LBM-55SAW which can place audio and video onto channels with a minimum 55dBmv output level.
- The Saw Filtered Mini-Modulator LCM-45 which is a high performance mini modulator that can modulate channels 2 to 125 with a minimum 45dBmv output level.
- The 24-Input Combiner LBC-24 which can combine the outputs of 24 modulators or processors into a single output with -30dB port-to-port isolation.
The document is a stock report from L.A. Micro Group (UK) Ltd listing various computer components they have in stock, including quantities. It includes backplanes, batteries/PDUs, bezels, and cables from manufacturers like Dell, HP, IBM, Cisco, and APC. There are over 100 individual items listed with descriptions and quantities ranging from 1 to 48 units.
American Fibertek MTX-91685C-SL User ManualJMAC Supply
Buy the American Fibertek MTX-91685C-SL at JMAC Supply.
https://www.jmac.com/American_Fibertek_MTX_91685C_SL_p/american-fibertek-mtx-91685csl.htm?=slideshare
Virtualizing the Network to enable a Software Defined Infrastructure (SDI)Odinot Stanislas
Une très intéressante présentation autour de la virtualisation des réseaux contenant des explications détaillées autour des VLAN, VXLAN, mais aussi d'NVGRE et surtout de GENEVE (Generic Network Virtualization Encapsulation) supporté pour la première fois sur la dernière carte 40 GbE d'Intel (XL710)
This document provides installation and operation instructions for the SSM23Q/IP integrated step-servo motor. It includes:
1. An overview of the motor's features such as torque capabilities, control modes, inputs/outputs, and Ethernet communication.
2. Instructions for installing the necessary software, mounting the motor, and choosing an appropriate power supply.
3. Details on connecting the power supply, connecting the motor to a PC over Ethernet, and descriptions of the input and output connections.
4. Contact information for support.
This document provides instructions for installing an outdoor pool and spa system. It discusses:
- Having a qualified electrician install the electrical components according to code
- Connecting the system to a dedicated circuit protected by a GFCI
- Connecting components such as pumps, blowers, and lights to color-coded receptacles
- Configuring universal circuits for 120V or 240V operation
- Installing the control panel and temperature sensor
- Connecting a gas heater according to the manufacturer's instructions
- Bypassing pressure or flow switches if needed
- Adjusting the pressure switch if issues arise related to water flow
The document provides an overview and instructions for configuring and using the Danfoss Ethernet Master gateway. The Ethernet Master allows communication between Danfoss VLT frequency drives on an FC-bus network and an Ethernet network, enabling control and monitoring of the drives from a PLC or HMI. Key features include: connecting up to 16 drives; IP address configuration via DIP switches, ARP command, or Netbiter tool; monitoring drives via built-in web server; and memory mapping for control/status data exchange with drives.
The document provides troubleshooting guidance for common issues with wireless switches, including: switch boot up problems, IP address assignment via DHCP, connectivity issues using Telnet/SSH, slow or unresponsive web interface, faulty console port, VLAN configuration loss after reboot, access port adoption failures, mobile unit association problems, failover malfunctions, version number changes after upgrades, excessive network traffic, and memory leaks. It also describes the system status LEDs and logging mechanism to help diagnose issues.
This document provides information about TNC connectors made by CMPTER Electronics, including:
- Technical specifications for TNC connectors including impedance, frequency range, and environmental tolerances
- Interface dimensions and tolerances for TNC connectors compliant with international standards
- Pictures and part numbers for various TNC cable connectors and receptacles with details on assembly instructions
This document provides installation instructions for the Motorola RFS7000 Series RF Switch. It describes the physical specifications, power requirements, port connections including Ethernet, USB, and console ports, as well as instructions for rack mounting and powering on the device. LED codes and patterns are explained to verify proper installation and operation.
The document provides installation instructions for the Motorola RFS6000 Series RF Switch. It includes specifications for the switch, descriptions of the LED codes on the front panel, and step-by-step instructions for hardware setup including cabling, rack mounting, connecting power and verifying installation. The introduction describes the purpose of the switch in centralizing wireless LAN configuration and management.
The LayerZero Series 70: eRDP-FS is a Remote Distribution Panel. Equipped with a built-in touch screen panel, eRDP-FS captures essential power quality information, including real-time waveform capture.
Designed and manufactured by LayerZero Power Systems in Aurora, Ohio USA.
This document provides instructions for installing and configuring an ADSL2+ modem. It includes sections on hardware installation, connecting to the internet, configuring local network and DHCP server settings, checking status, resetting to default settings, and specifications. The document contains diagrams of the modem hardware and definitions of acronyms used.
- IPv6 EIGRP requires enabling IPv6 unicast routing and configuring a router ID before EIGRP can function. The ipv6 eigrp interface command must be used on all participating interfaces instead of the network command.
- Neighbor relationships form when interfaces are configured and hello packets are exchanged. Show commands display neighbor, protocol, and route information for troubleshooting. Summarization and redistribution can be used to manipulate route advertisements between routers.
This document describes the RFM73 2.4GHz transceiver chip, including its features, modes of operation, packet processing, and register interface. The chip operates in the 2.4GHz ISM band and supports data rates up to 2Mbps. It has a SPI interface and integrated packet handling for low-power wireless applications such as mice, keyboards, and remote controls.
The document is the installation and user guide for the DN100 Outdoor Wireless Intelligent Access Point. It provides instructions on planning, installing, and configuring the DN100 for use as a wireless access point or wireless backhaul link. The guide covers topics such as radio frequency planning, antenna installation, Ethernet cabling, power supply, and initial configuration of the device's network settings and security. It also includes the DN100 specifications, limited warranty information, and contact details for technical support.
Electric Control Valve Actuators for Industrial Process ApplicationsCTi Controltech
The Rotork CVA line of electric process control actuators offers a highly accurate and responsive method of automating control valves, without the complexity and cost of a pneumatic supply. With an increased focus on production costs and efficiency, accurate control of product through the pipeline is paramount. With resolution figures better than 0.1% and the ability to eliminate position overshoot, the Rotork CVA models help to maximize product quality and plant capacity.
This document provides guidance on selecting and installing surge protection devices (SPDs) for process control systems to protect sensitive electronics from electrical surges. It discusses SPD placement for different applications including hazardous areas, analog and digital I/O, high current signals up to 6A, 4-20mA loops, interposing relays, RTDs, HART communication, and RS232/RS485. SPDs should be installed at both ends of cable runs connecting PLCs, field instruments, and I/O to provide adequate protection from surges traveling on cables.
The document provides information on various headend equipment from PDT Ltd including modulators, demodulators, combiners, and accessories. Key products described include:
- The 19 inch Audio/Video Modulator LBM-55SAW which can place audio and video onto channels with a minimum 55dBmv output level.
- The Saw Filtered Mini-Modulator LCM-45 which is a high performance mini modulator that can modulate channels 2 to 125 with a minimum 45dBmv output level.
- The 24-Input Combiner LBC-24 which can combine the outputs of 24 modulators or processors into a single output with -30dB port-to-port isolation.
The document is a stock report from L.A. Micro Group (UK) Ltd listing various computer components they have in stock, including quantities. It includes backplanes, batteries/PDUs, bezels, and cables from manufacturers like Dell, HP, IBM, Cisco, and APC. There are over 100 individual items listed with descriptions and quantities ranging from 1 to 48 units.
American Fibertek MTX-91685C-SL User ManualJMAC Supply
Buy the American Fibertek MTX-91685C-SL at JMAC Supply.
https://www.jmac.com/American_Fibertek_MTX_91685C_SL_p/american-fibertek-mtx-91685csl.htm?=slideshare
Virtualizing the Network to enable a Software Defined Infrastructure (SDI)Odinot Stanislas
Une très intéressante présentation autour de la virtualisation des réseaux contenant des explications détaillées autour des VLAN, VXLAN, mais aussi d'NVGRE et surtout de GENEVE (Generic Network Virtualization Encapsulation) supporté pour la première fois sur la dernière carte 40 GbE d'Intel (XL710)
This document provides installation and operation instructions for the SSM23Q/IP integrated step-servo motor. It includes:
1. An overview of the motor's features such as torque capabilities, control modes, inputs/outputs, and Ethernet communication.
2. Instructions for installing the necessary software, mounting the motor, and choosing an appropriate power supply.
3. Details on connecting the power supply, connecting the motor to a PC over Ethernet, and descriptions of the input and output connections.
4. Contact information for support.
The document discusses virtualization and its implementation at GHCL Ltd's Sutrapada facility. It defines virtualization as creating virtual versions of operating systems, storage, and network resources. The goals of virtualization are to centralize administration, improve scalability and hardware utilization. Types of virtualization discussed include full, partial, and para virtualization. The document outlines how virtual machines are created, monitored, snapshotted, migrated, and used for failover. It provides an example virtualization implementation at GHCL including resource planning and allocation across three physical servers. Finally, it discusses desktop virtualization and its advantages over traditional desktop computing.
IRJET - Automated Monitoring Test Rig for Circuit Breaker OperationIRJET Journal
1) The document describes an automated monitoring system for circuit breakers that records voltage, current, and switching time data.
2) The system uses a microprocessor, sensors, and wireless communication to acquire and transmit data from multiple circuit breakers to a central computer for analysis.
3) Analyzing circuit breaker operation data and the sequence of events during faults can help evaluate breaker performance, detect issues, and ensure the power system's topology and protection operate as intended.
SON Server Web KPI Portal 4G DT Analysis Cases Module.pptxssuser2b76bb
SON (Self Organized Network) software automates various network optimization functions including automatic neighbor relations, coverage optimization, interference management, and sleeping cell detection and resolution. Key SON modules identify issues like crossed antennas, scrambling code collisions, and outage compensation. Intelligent reports in BSNL's KPI web portal provide insights into network performance and issues found through drive testing like orientation mismatches, cable swaps, and poor signal interference between sites.
This document provides details about Circuit Switched Dynamic Abis Pool (CSDAP), a feature that offers a common Abis transmission pool that can be shared by all speech calls in a base station control function (BCF) cabinet. CSDAP allows for the creation of transmission pools of 64 kbps timeslots that can be dynamically allocated for orthogonal subchannel circuit switched traffic. The document covers CSDAP requirements, functionality, system impacts, user interface parameters, and how to activate and deactivate the feature.
The document is a user manual for the H820 series industrial grade 2G, 3G, and 4G cellular routers made by E-Lins Technology Co., Limited. It provides instructions on hardware installation of the router, including dimensions, port descriptions, SIM card insertion, terminal block installation, grounding, and power supply connection. It also covers checking network status and preparing for software configuration.
This document provides instructions for configuring and enabling Single Radio Voice Call Continuity (SRVCC) on an MSC server. It describes how to initialize the Sv interface and SRVCC application when no SRVCC is configured, including configuring the IP stack, signaling transport, SIP routes, area clusters, and analysis functions. It also provides steps for initializing and configuring LTE to GSM handover, LTE to WCDMA handover, SRVCC for emergency calls, VoLTE S8HR for SRVCC, robust SRVCC, and other SRVCC features. The document includes sections on configuration parameters, adding and removing MMEs, and maintenance procedures.
This document provides a summary of the configuration steps for data on a ZXWR RNC (V3.07.310) radio network controller. It includes global RNC configuration, fast configuration of RNC ground resources and NodeBs, RNC ground resource management, radio resource management, and MML character terminal settings. The document contains detailed instructions and flowcharts to guide users through various interface, resource, and network element configurations for the RNC system.
This document provides a summary of the configuration steps for data on a ZXWR RNC (V3.07.310) radio network controller. It includes global RNC configuration, fast configuration of RNC ground resources and NodeBs, RNC ground resource management, radio resource management, and MML character terminal settings. The document contains detailed instructions and flowcharts to guide users through various interface, resource, and network element configurations for the RNC system.
This document provides a summary of the configuration steps for data on a ZXWR RNC (V3.07.310) radio network controller, including:
1. Global RNC configuration such as creating a UTRAN subnetwork and RNC managed element.
2. Fast configuration of RNC ground resources, NodeBs, and radio resources.
3. Detailed configuration of RNC ground resources including physical resources, transmission configuration, NE information, and Sigtran.
It is intended for internal use at ZTE Corporation and contains 94 pages of technical documentation.
The document provides guidelines for configuring traffic shaping on customer premises equipment (CPE) to properly handle traffic for an Exetel internet service. It recommends allowing a 2% overhead for layer 2 Ethernet and outlines a two-step process to define a policy map matching the purchased bandwidth and apply it to the outbound interface. Exetel support is available to assist with any traffic shaping configuration questions.
The document provides instructions for configuring Ethernet interfaces and link aggregation on Huawei switches. It includes:
1) Manually setting the line rate and duplex mode of Ethernet interfaces on switches S1 and S2 to 100Mbps full duplex.
2) Creating an Ethernet trunk (Eth-Trunk 1) on S1 and S2 and adding interfaces G0/0/9 and G0/0/10 to configure manual link aggregation between the switches.
3) Deleting the manual link aggregation configurations in preparation for configuring static LACP mode aggregation on the same interfaces.
This document describes a transformer health monitoring system that uses Internet of Things (IoT) technology. Sensors are used to monitor critical parameters like load current, voltage, oil temperature, humidity, and oil level. The sensor data is sent to a microcontroller and uploaded to an IoT web server using WiFi. This allows real-time monitoring of the transformer's condition and alerts operators to any issues before failures occur. The system aims to improve on traditional monitoring methods by providing continuous multi-parameter monitoring from remote locations using low-cost IoT technologies.
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...PROIDEA
This document discusses data center networking and virtualization challenges. It provides an overview of Extreme Networks' solutions, including their "four pillars" approach of automated, customized, scalable and efficient networking. It discusses issues with virtualized networks like VM mobility and network visibility. Extreme Networks' XNV solution provides network visibility into the VM lifecycle. It also discusses direct attach architectures and how they can reduce network tiers both physically and virtually.
The document describes a network security project for a large South Indian bank. The project aimed to implement network security across the bank's datacenter addressing various network segments. Key challenges included a lack of datacenter firewalls and proactive defense mechanisms. The solution implemented Cisco firewall, IDS, and security management technologies to logically segment the network and provide layered defenses, resulting in no security issues during the implementation period.
The document describes the Series 70 eRPP-FS remote power panel from LayerZero Power Systems. It increases reliability and safety in two ways: with a finger-safe panel board design and selective trip coordination of circuit breakers. Key features include silver-plated terminals, convection cooling, serialized critical components, power quality monitoring, Ethernet connectivity, and safety mechanisms like insulated screws and polycarbonate windows.
This document provides an overview of the Cisco 12000 Series Gigabit Switch Routers. It describes the key features and capabilities of the Cisco
12000 series including scalable bandwidth up to 80Gbps, high-density interfaces, redundancy, hot-swap capability, and carrier-class design. It
also discusses the distributed routing architecture, scalable performance through intelligent line cards, and ability to support services through
Cisco IOS software.
This document is a product manual for Maxtor hard disk drives that provides technical information for installation and use. It discusses Maxtor as a company, outlines the product features and specifications of their hard drives, and provides guidance on handling, installing, interfacing and supporting the drives. The manual is intended for OEM engineers and system integrators.
The document describes the steps for installing three Motorola private broadband network product families:
1. The T3 PowerBroadband System extends Ethernet over single-pair telephone wiring up to 600 meters and provides line power to wallplate devices.
2. The XLP-6800 Extended PoE System extends Ethernet over two or four pairs up to 3,000 meters and provides line power and PoE to connected devices.
3. The XLP-7000 Extended PoE System extends Ethernet over single-pair wiring up to 1,500 meters and provides line power and PoE to connected devices.
The installation process involves installing the core switch in a wiring closet, running cross connects to wallplates or
Introduction of Cybersecurity with OSS at Code Europe 2024Hiroshi SHIBATA
I develop the Ruby programming language, RubyGems, and Bundler, which are package managers for Ruby. Today, I will introduce how to enhance the security of your application using open-source software (OSS) examples from Ruby and RubyGems.
The first topic is CVE (Common Vulnerabilities and Exposures). I have published CVEs many times. But what exactly is a CVE? I'll provide a basic understanding of CVEs and explain how to detect and handle vulnerabilities in OSS.
Next, let's discuss package managers. Package managers play a critical role in the OSS ecosystem. I'll explain how to manage library dependencies in your application.
I'll share insights into how the Ruby and RubyGems core team works to keep our ecosystem safe. By the end of this talk, you'll have a better understanding of how to safeguard your code.
How to Interpret Trends in the Kalyan Rajdhani Mix Chart.pdfChart Kalyan
A Mix Chart displays historical data of numbers in a graphical or tabular form. The Kalyan Rajdhani Mix Chart specifically shows the results of a sequence of numbers over different periods.
Freshworks Rethinks NoSQL for Rapid Scaling & Cost-EfficiencyScyllaDB
Freshworks creates AI-boosted business software that helps employees work more efficiently and effectively. Managing data across multiple RDBMS and NoSQL databases was already a challenge at their current scale. To prepare for 10X growth, they knew it was time to rethink their database strategy. Learn how they architected a solution that would simplify scaling while keeping costs under control.
Northern Engraving | Nameplate Manufacturing Process - 2024Northern Engraving
Manufacturing custom quality metal nameplates and badges involves several standard operations. Processes include sheet prep, lithography, screening, coating, punch press and inspection. All decoration is completed in the flat sheet with adhesive and tooling operations following. The possibilities for creating unique durable nameplates are endless. How will you create your brand identity? We can help!
Discover top-tier mobile app development services, offering innovative solutions for iOS and Android. Enhance your business with custom, user-friendly mobile applications.
Monitoring and Managing Anomaly Detection on OpenShift.pdfTosin Akinosho
Monitoring and Managing Anomaly Detection on OpenShift
Overview
Dive into the world of anomaly detection on edge devices with our comprehensive hands-on tutorial. This SlideShare presentation will guide you through the entire process, from data collection and model training to edge deployment and real-time monitoring. Perfect for those looking to implement robust anomaly detection systems on resource-constrained IoT/edge devices.
Key Topics Covered
1. Introduction to Anomaly Detection
- Understand the fundamentals of anomaly detection and its importance in identifying unusual behavior or failures in systems.
2. Understanding Edge (IoT)
- Learn about edge computing and IoT, and how they enable real-time data processing and decision-making at the source.
3. What is ArgoCD?
- Discover ArgoCD, a declarative, GitOps continuous delivery tool for Kubernetes, and its role in deploying applications on edge devices.
4. Deployment Using ArgoCD for Edge Devices
- Step-by-step guide on deploying anomaly detection models on edge devices using ArgoCD.
5. Introduction to Apache Kafka and S3
- Explore Apache Kafka for real-time data streaming and Amazon S3 for scalable storage solutions.
6. Viewing Kafka Messages in the Data Lake
- Learn how to view and analyze Kafka messages stored in a data lake for better insights.
7. What is Prometheus?
- Get to know Prometheus, an open-source monitoring and alerting toolkit, and its application in monitoring edge devices.
8. Monitoring Application Metrics with Prometheus
- Detailed instructions on setting up Prometheus to monitor the performance and health of your anomaly detection system.
9. What is Camel K?
- Introduction to Camel K, a lightweight integration framework built on Apache Camel, designed for Kubernetes.
10. Configuring Camel K Integrations for Data Pipelines
- Learn how to configure Camel K for seamless data pipeline integrations in your anomaly detection workflow.
11. What is a Jupyter Notebook?
- Overview of Jupyter Notebooks, an open-source web application for creating and sharing documents with live code, equations, visualizations, and narrative text.
12. Jupyter Notebooks with Code Examples
- Hands-on examples and code snippets in Jupyter Notebooks to help you implement and test anomaly detection models.
"Scaling RAG Applications to serve millions of users", Kevin GoedeckeFwdays
How we managed to grow and scale a RAG application from zero to thousands of users in 7 months. Lessons from technical challenges around managing high load for LLMs, RAGs and Vector databases.
Fueling AI with Great Data with Airbyte WebinarZilliz
This talk will focus on how to collect data from a variety of sources, leveraging this data for RAG and other GenAI use cases, and finally charting your course to productionalization.
This talk will cover ScyllaDB Architecture from the cluster-level view and zoom in on data distribution and internal node architecture. In the process, we will learn the secret sauce used to get ScyllaDB's high availability and superior performance. We will also touch on the upcoming changes to ScyllaDB architecture, moving to strongly consistent metadata and tablets.
"Frontline Battles with DDoS: Best practices and Lessons Learned", Igor IvaniukFwdays
At this talk we will discuss DDoS protection tools and best practices, discuss network architectures and what AWS has to offer. Also, we will look into one of the largest DDoS attacks on Ukrainian infrastructure that happened in February 2022. We'll see, what techniques helped to keep the web resources available for Ukrainians and how AWS improved DDoS protection for all customers based on Ukraine experience
Connector Corner: Seamlessly power UiPath Apps, GenAI with prebuilt connectorsDianaGray10
Join us to learn how UiPath Apps can directly and easily interact with prebuilt connectors via Integration Service--including Salesforce, ServiceNow, Open GenAI, and more.
The best part is you can achieve this without building a custom workflow! Say goodbye to the hassle of using separate automations to call APIs. By seamlessly integrating within App Studio, you can now easily streamline your workflow, while gaining direct access to our Connector Catalog of popular applications.
We’ll discuss and demo the benefits of UiPath Apps and connectors including:
Creating a compelling user experience for any software, without the limitations of APIs.
Accelerating the app creation process, saving time and effort
Enjoying high-performance CRUD (create, read, update, delete) operations, for
seamless data management.
Speakers:
Russell Alfeche, Technology Leader, RPA at qBotic and UiPath MVP
Charlie Greenberg, host
LF Energy Webinar: Carbon Data Specifications: Mechanisms to Improve Data Acc...DanBrown980551
This LF Energy webinar took place June 20, 2024. It featured:
-Alex Thornton, LF Energy
-Hallie Cramer, Google
-Daniel Roesler, UtilityAPI
-Henry Richardson, WattTime
In response to the urgency and scale required to effectively address climate change, open source solutions offer significant potential for driving innovation and progress. Currently, there is a growing demand for standardization and interoperability in energy data and modeling. Open source standards and specifications within the energy sector can also alleviate challenges associated with data fragmentation, transparency, and accessibility. At the same time, it is crucial to consider privacy and security concerns throughout the development of open source platforms.
This webinar will delve into the motivations behind establishing LF Energy’s Carbon Data Specification Consortium. It will provide an overview of the draft specifications and the ongoing progress made by the respective working groups.
Three primary specifications will be discussed:
-Discovery and client registration, emphasizing transparent processes and secure and private access
-Customer data, centering around customer tariffs, bills, energy usage, and full consumption disclosure
-Power systems data, focusing on grid data, inclusive of transmission and distribution networks, generation, intergrid power flows, and market settlement data
The Microsoft 365 Migration Tutorial For Beginner.pptxoperationspcvita
This presentation will help you understand the power of Microsoft 365. However, we have mentioned every productivity app included in Office 365. Additionally, we have suggested the migration situation related to Office 365 and how we can help you.
You can also read: https://www.systoolsgroup.com/updates/office-365-tenant-to-tenant-migration-step-by-step-complete-guide/
zkStudyClub - LatticeFold: A Lattice-based Folding Scheme and its Application...Alex Pruden
Folding is a recent technique for building efficient recursive SNARKs. Several elegant folding protocols have been proposed, such as Nova, Supernova, Hypernova, Protostar, and others. However, all of them rely on an additively homomorphic commitment scheme based on discrete log, and are therefore not post-quantum secure. In this work we present LatticeFold, the first lattice-based folding protocol based on the Module SIS problem. This folding protocol naturally leads to an efficient recursive lattice-based SNARK and an efficient PCD scheme. LatticeFold supports folding low-degree relations, such as R1CS, as well as high-degree relations, such as CCS. The key challenge is to construct a secure folding protocol that works with the Ajtai commitment scheme. The difficulty, is ensuring that extracted witnesses are low norm through many rounds of folding. We present a novel technique using the sumcheck protocol to ensure that extracted witnesses are always low norm no matter how many rounds of folding are used. Our evaluation of the final proof system suggests that it is as performant as Hypernova, while providing post-quantum security.
Paper Link: https://eprint.iacr.org/2024/257
Your One-Stop Shop for Python Success: Top 10 US Python Development Providersakankshawande
Simplify your search for a reliable Python development partner! This list presents the top 10 trusted US providers offering comprehensive Python development services, ensuring your project's success from conception to completion.
inQuba Webinar Mastering Customer Journey Management with Dr Graham HillLizaNolte
HERE IS YOUR WEBINAR CONTENT! 'Mastering Customer Journey Management with Dr. Graham Hill'. We hope you find the webinar recording both insightful and enjoyable.
In this webinar, we explored essential aspects of Customer Journey Management and personalization. Here’s a summary of the key insights and topics discussed:
Key Takeaways:
Understanding the Customer Journey: Dr. Hill emphasized the importance of mapping and understanding the complete customer journey to identify touchpoints and opportunities for improvement.
Personalization Strategies: We discussed how to leverage data and insights to create personalized experiences that resonate with customers.
Technology Integration: Insights were shared on how inQuba’s advanced technology can streamline customer interactions and drive operational efficiency.
34. 洛阳市第二中医院网络竣工文档
7 网络设备的配置信息
7.1 网络设备配置信息的附件
DCRS-6808E-A 20120316.lo g
DCRS-6808E-B 20120316.lo g
DCRS-5950-28T 20120316.lo g
33 / 91
神州数码网络有限公司技术支持电话:4008109119
35. 洛阳市第二中医院网络竣工文档
7.2 核心交换机 DCRS-6808E-A 配置
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#show slot
--------------------Slot : 1--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 2--------------------
Inserted : YES
Module type : MRS-6800E-2XFP12GX12GB
Work mode : SLAVE
Work state : RUNNING
Local software version : 6.2.42.0
Bootrom version : 4.0.2
Hardware version : 3.0
Serial number : N114100050
Manufacture date : 2011/10/11
Temperature : 34C/93F
Uptime : 0 weeks, 0 days, 7 hours, 42 minutes
--------------------Slot : 3--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 4--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
34 / 91
神州数码网络有限公司技术支持电话:4008109119
36. 洛阳市第二中医院网络竣工文档
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : M1--------------------
Inserted : YES
Module type : MRS-6808E-M(R2)
Work mode : ACTIVE MASTER
Work state : RUNNING
Software package version : 6.2.42.0
Local software version : 6.2.42.0
Bootrom version : 4.0.2
Hardware version : 4.0
Serial number : N114100128
Manufacture date : 2011/10/15
Temperature : 31C/87F
Uptime : 0 weeks, 0 days, 7 hours, 42 minutes
--------------------Slot : M2--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 5--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 6--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
35 / 91
神州数码网络有限公司技术支持电话:4008109119
37. 洛阳市第二中医院网络竣工文档
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 7--------------------
Inserted : YES
Module type : MRS-6800E-12GX12GB
Work mode : SLAVE
Work state : RUNNING
Local software version : 6.2.42.0
Bootrom version : 4.0.2
Hardware version : 3.0
Serial number : N113400081
Manufacture date : 2011/08/23
Temperature : 32C/89F
Uptime : 0 weeks, 0 days, 7 hours, 42 minutes
--------------------Slot : 8--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#show running-config
!
no service password-encryption
!
hostname DCRS-6808E-A
sysLocation China
sysContact 800-810-9119
!
username dezyy2012 privilege 15 password 0 dezyy2012
!
!
!
!
!
!
spanning-tree mst configuration
instance 0 vlan 1-10;15-4094
instance 1 vlan 11-14
exit
!
36 / 91
神州数码网络有限公司技术支持电话:4008109119
43. 洛阳市第二中医院网络竣工文档
2/2 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-6808E-B_port2/2
2/3 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-5950-28T_port1/1
2/4 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-5950-28T_port1/2
2/5 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_1Floor_DCS-4500-26T_port1/25
2/6 DOWN/DOWN auto auto trunk G-Combo
2/7 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_2Floor_DCS-4500-26T_port1/25
2/8 DOWN/DOWN auto auto trunk G-Combo
2/9 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_3Floor_DCS-4500-26T_port1/25
2/10 DOWN/DOWN auto auto trunk G-Combo
2/11 DOWN/DOWN auto auto trunk G-Combo
2/12 DOWN/DOWN auto auto trunk G-Combo
2/13 DOWN/DOWN auto auto trunk SFP
2/14 DOWN/DOWN auto auto trunk SFP
2/15 DOWN/DOWN auto auto trunk SFP
2/16 DOWN/DOWN auto auto trunk SFP
2/17 DOWN/DOWN auto auto trunk SFP
2/18 DOWN/DOWN auto auto trunk SFP
2/19 DOWN/DOWN auto auto trunk SFP
2/20 DOWN/DOWN auto auto trunk SFP
2/21 DOWN/DOWN auto auto trunk SFP
2/22 DOWN/DOWN auto auto trunk SFP
2/23 DOWN/DOWN auto auto trunk SFP
2/24 DOWN/DOWN auto auto trunk SFP
2/25 DOWN/DOWN auto auto trunk XFP
2/26 DOWN/DOWN auto auto trunk XFP
7/1 DOWN/DOWN auto auto 10 G-Combo
7/2 DOWN/DOWN auto auto 10 G-Combo
7/3 DOWN/DOWN auto auto 10 G-Combo
7/4 DOWN/DOWN auto auto 10 G-Combo
7/5 DOWN/DOWN auto auto 10 G-Combo
7/6 DOWN/DOWN auto auto 10 G-Combo
7/7 DOWN/DOWN auto auto 10 G-Combo
7/8 DOWN/DOWN auto auto 10 G-Combo
7/9 DOWN/DOWN auto auto 10 G-Combo
7/10 DOWN/DOWN auto auto 10 G-Combo
7/11 DOWN/DOWN auto auto 10 G-Combo
7/12 DOWN/DOWN auto auto 10 G-Combo
7/13 DOWN/DOWN auto auto trunk SFP
7/14 DOWN/DOWN auto auto trunk SFP
7/15 DOWN/DOWN auto auto trunk SFP
7/16 DOWN/DOWN auto auto trunk SFP
7/17 DOWN/DOWN auto auto trunk SFP
7/18 DOWN/DOWN auto auto trunk SFP
7/19 DOWN/DOWN auto auto trunk SFP
7/20 DOWN/DOWN auto auto trunk SFP
7/21 DOWN/DOWN auto auto trunk SFP
7/22 DOWN/DOWN auto auto trunk SFP
7/23 DOWN/DOWN auto auto trunk SFP
42 / 91
神州数码网络有限公司技术支持电话:4008109119
44. 洛阳市第二中医院网络竣工文档
7/24 DOWN/DOWN auto auto trunk SFP
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#show ip interface brief
Index Interface IP-Address Protocol
3001 Vlan1 10.10.10.252 up
10.10.10.254 (secondary)
3010 Vlan10 100.100.104.200 up
100.100.104.193 (secondary)
3011 Vlan11 172.16.1.252 up
3012 Vlan12 172.16.2.252 up
3013 Vlan13 172.16.3.252 up
3014 Vlan14 172.16.4.252 up
9000 Loopback 127.0.0.1 up
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#show vrrp
VrId 1
State is Master
Virtual IP is 10.10.10.254 (Not IP owner)
Interface is Vlan1
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 10
State is Master
Virtual IP is 100.100.104.193 (Not IP owner)
Interface is Vlan10
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 11
State is Backup
Virtual IP is 172.16.1.254 (Not IP owner)
Interface is Vlan11
Priority is 100
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 12
State is Backup
Virtual IP is 172.16.2.254 (Not IP owner)
Interface is Vlan12
Priority is 100
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 13
State is Backup
Virtual IP is 172.16.3.254 (Not IP owner)
Interface is Vlan13
Priority is 100
Advertisement interval is 1 sec
43 / 91
神州数码网络有限公司技术支持电话:4008109119
45. 洛阳市第二中医院网络竣工文档
Preempt mode is TRUE
VrId 14
State is Backup
Virtual IP is 172.16.4.254 (Not IP owner)
Interface is Vlan14
Priority is 100
Advertisement interval is 1 sec
Preempt mode is TRUE
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#show spanning-tree
-- MSTP Bridge Config Info --
Standard : IEEE 802.1s
Bridge MAC : 00:03:0f:1a:5b:40
Bridge Times : Max Age 20, Hello Time 2, Forward Delay 15
Force Version: 3
########################### Instance 0 ###########################
Self Bridge Id : 0 - 00:03:0f:1a:5b:40
Root Id : this switch
Ext.RootPathCost : 0
Region Root Id : this switch
Int.RootPathCost : 0
Root Port ID :0
Current port list in Instance 0:
Port-Channel1 Port-Channel2 Port-Channel4 Port-Channel5 Port-Channel6
(Total 5)
PortName ID ExtRPC IntRPC State Role DsgBridge DsgPort
-------------- -------- --------- --------- --- ---- ------------------ --------
Port-Channel1 128.641 0 0 FWD DSGN 0.00030f1a5b40 128.641
Port-Channel2 128.642 0 0 FWD DSGN 0.00030f1a5b40 128.642
Port-Channel4 128.644 0 0 FWD DSGN 0.00030f1a5b40 128.644
Port-Channel5 128.645 0 0 FWD DSGN 0.00030f1a5b40 128.645
Port-Channel6 128.646 0 0 FWD DSGN 0.00030f1a5b40 128.646
########################### Instance 1 ###########################
Self Bridge Id : 4096.00:03:0f:1a:5b:40
Region Root Id : 0.00:03:0f:1a:5b:6d
Int.RootPathCost : 10000
Root Port ID : 128.641
Current port list in Instance 1:
Port-Channel1 Port-Channel2 Port-Channel4 Port-Channel5 Port-Channel6
(Total 5)
PortName ID IntRPC State Role DsgBridge DsgPort
-------------- -------- --------- --- ---- ------------------ -------
Port-Channel1 128.641 0 FWD ROOT 0.00030f1a5b6d 128.641
Port-Channel2 128.642 10000 FWD DSGN 4096.00030f1a5b40 128.642
Port-Channel4 128.644 10000 FWD DSGN 4096.00030f1a5b40 128.644
Port-Channel5 128.645 10000 FWD DSGN 4096.00030f1a5b40 128.645
44 / 91
神州数码网络有限公司技术支持电话:4008109119
46. 洛阳市第二中医院网络竣工文档
Port-Channel6 128.646 10000 FWD DSGN 4096.00030f1a5b40 128.646
DCRS-6808E-A#
DCRS-6808E-A#
DCRS-6808E-A#wr
Confirm to overwrite current startup-config configuration [Y/N]:y
Write running-config to current startup-config successful
DCRS-6808E-A#
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#
45 / 91
神州数码网络有限公司技术支持电话:4008109119
47. 洛阳市第二中医院网络竣工文档
7.3 核心交换机 DCRS-6808E-B 配置
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#show slot
--------------------Slot : 1--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 2--------------------
Inserted : YES
Module type : MRS-6800E-2XFP12GX12GB
Work mode : SLAVE
Work state : RUNNING
Local software version : 6.2.42.0
Bootrom version : 3.0.15
Hardware version : 3.0
Serial number : N114100016
Manufacture date : 2011/10/10
Temperature : 34C/93F
Uptime : 0 weeks, 1 days, 2 hours, 35 minutes
--------------------Slot : 3--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 4--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
46 / 91
神州数码网络有限公司技术支持电话:4008109119
48. 洛阳市第二中医院网络竣工文档
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : M1--------------------
Inserted : YES
Module type : MRS-6808E-M(R2)
Work mode : ACTIVE MASTER
Work state : RUNNING
Software package version : 6.2.42.0
Local software version : 6.2.42.0
Bootrom version : 4.0.2
Hardware version : 4.0
Serial number : N114100139
Manufacture date : 2011/10/15
Temperature : 31C/87F
Uptime : 0 weeks, 1 days, 2 hours, 35 minutes
--------------------Slot : M2--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 5--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 6--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
47 / 91
神州数码网络有限公司技术支持电话:4008109119
49. 洛阳市第二中医院网络竣工文档
Serial number :
Manufacture date :
Temperature :
Uptime :
--------------------Slot : 7--------------------
Inserted : YES
Module type : MRS-6800E-12GX12GB
Work mode : SLAVE
Work state : RUNNING
Local software version : 6.2.42.0
Bootrom version : 3.0.15
Hardware version : 3.0
Serial number : N113400100
Manufacture date : 2011/08/23
Temperature : 31C/87F
Uptime : 0 weeks, 1 days, 2 hours, 35 minutes
--------------------Slot : 8--------------------
Inserted : NO
Module type : UNKNOWN
Work mode : UNKNOWN
Work state : NONE
Local software version :
Bootrom version :
Hardware version :
Serial number :
Manufacture date :
Temperature :
Uptime :
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#show running-config
!
no service password-encryption
!
hostname DCRS-6808E-B
sysLocation China
sysContact 800-810-9119
!
username dezyy2012 privilege 15 password 0 dezyy2012
!
!
!
!
!
!
spanning-tree mst configuration
instance 0 vlan 1-10;15-4094
instance 1 vlan 11-14
exit
!
spanning-tree
spanning-tree mst 0 priority 4096
48 / 91
神州数码网络有限公司技术支持电话:4008109119
55. 洛阳市第二中医院网络竣工文档
Interface Link/Protocol Speed Duplex Vlan Type Alias Name
2/1 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-6808E-B_port2/1
2/2 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-6808E-B_port2/2
2/3 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-5950-28T_port1/3
2/4 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_DCRS-5950-28T_port1/4
2/5 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_1Floor_DCS-4500-26T_port1/26
2/6 DOWN/DOWN auto auto trunk G-Combo
2/7 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_2Floor_DCS-4500-26T_port1/26
2/8 DOWN/DOWN auto auto trunk G-Combo
2/9 UP/UP a-1G a-FULL trunk G-Combo:Copper
TO_MenZhenLou_3Floor_DCS-4500-26T_port1/26
2/10 DOWN/DOWN auto auto trunk G-Combo
2/11 DOWN/DOWN auto auto trunk G-Combo
2/12 DOWN/DOWN auto auto trunk G-Combo
2/13 DOWN/DOWN auto auto trunk SFP
2/14 DOWN/DOWN auto auto trunk SFP
2/15 DOWN/DOWN auto auto trunk SFP
2/16 DOWN/DOWN auto auto trunk SFP
2/17 DOWN/DOWN auto auto trunk SFP
2/18 DOWN/DOWN auto auto trunk SFP
2/19 DOWN/DOWN auto auto trunk SFP
2/20 DOWN/DOWN auto auto trunk SFP
2/21 DOWN/DOWN auto auto trunk SFP
2/22 DOWN/DOWN auto auto trunk SFP
2/23 DOWN/DOWN auto auto trunk SFP
2/24 DOWN/DOWN auto auto trunk SFP
2/25 DOWN/DOWN auto auto trunk XFP
2/26 DOWN/DOWN auto auto trunk XFP
7/1 DOWN/DOWN auto auto 10 G-Combo
7/2 DOWN/DOWN auto auto 10 G-Combo
7/3 DOWN/DOWN auto auto 10 G-Combo
7/4 DOWN/DOWN auto auto 10 G-Combo
7/5 DOWN/DOWN auto auto 10 G-Combo
7/6 DOWN/DOWN auto auto 10 G-Combo
7/7 DOWN/DOWN auto auto 10 G-Combo
7/8 DOWN/DOWN auto auto 10 G-Combo
7/9 DOWN/DOWN auto auto 10 G-Combo
7/10 DOWN/DOWN auto auto 10 G-Combo
7/11 DOWN/DOWN auto auto 10 G-Combo
7/12 DOWN/DOWN auto auto 10 G-Combo
7/13 DOWN/DOWN auto auto trunk SFP
7/14 DOWN/DOWN auto auto trunk SFP
7/15 DOWN/DOWN auto auto trunk SFP
7/16 DOWN/DOWN auto auto trunk SFP
7/17 DOWN/DOWN auto auto trunk SFP
7/18 DOWN/DOWN auto auto trunk SFP
7/19 DOWN/DOWN auto auto trunk SFP
54 / 91
神州数码网络有限公司技术支持电话:4008109119
56. 洛阳市第二中医院网络竣工文档
7/20 DOWN/DOWN auto auto trunk SFP
7/21 DOWN/DOWN auto auto trunk SFP
7/22 DOWN/DOWN auto auto trunk SFP
7/23 DOWN/DOWN auto auto trunk SFP
7/24 DOWN/DOWN auto auto trunk SFP
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#show ip interface brief
Index Interface IP-Address Protocol
3001 Vlan1 10.10.10.253 up
3010 Vlan10 100.100.104.201 up
3011 Vlan11 172.16.1.253 up
172.16.1.254 (secondary)
3012 Vlan12 172.16.2.253 up
172.16.2.254 (secondary)
3013 Vlan13 172.16.3.253 up
172.16.3.254 (secondary)
3014 Vlan14 172.16.4.253 up
172.16.4.254 (secondary)
9000 Loopback 127.0.0.1 up
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#show vrrp
VrId 1
State is Initialize
Virtual IP is 10.10.10.254 (Not IP owner)
Interface is Vlan1
Priority is 100
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 10
State is Backup
Virtual IP is 100.100.104.193 (Not IP owner)
Interface is Vlan10
Priority is 100
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 11
State is Master
Virtual IP is 172.16.1.254 (Not IP owner)
Interface is Vlan11
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 12
State is Master
Virtual IP is 172.16.2.254 (Not IP owner)
Interface is Vlan12
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
55 / 91
神州数码网络有限公司技术支持电话:4008109119
57. 洛阳市第二中医院网络竣工文档
VrId 13
State is Master
Virtual IP is 172.16.3.254 (Not IP owner)
Interface is Vlan13
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
VrId 14
State is Master
Virtual IP is 172.16.4.254 (Not IP owner)
Interface is Vlan14
Priority is 150
Advertisement interval is 1 sec
Preempt mode is TRUE
DCRS-6808E-B#
DCRS-6808E-B#
DCRS-6808E-B#show spanning-tree
-- MSTP Bridge Config Info --
Standard : IEEE 802.1s
Bridge MAC : 00:03:0f:1a:5b:6d
Bridge Times : Max Age 20, Hello Time 2, Forward Delay 15
Force Version: 3
########################### Instance 0 ###########################
Self Bridge Id : 4096 - 00:03:0f:1a:5b:6d
Root Id : 0.00:03:0f:1a:5b:40
Ext.RootPathCost : 0
Region Root Id : 0.00:03:0f:1a:5b:40
Int.RootPathCost : 10000
Root Port ID : 128.641
Current port list in Instance 0:
Port-Channel1 Port-Channel2 Port-Channel3 Port-Channel5 Port-Channel6
(Total 5)
PortName ID ExtRPC IntRPC State Role DsgBridge DsgPort
-------------- -------- --------- --------- --- ---- ------------------ --------
Port-Channel1 128.641 0 0 FWD ROOT 0.00030f1a5b40 128.641
Port-Channel2 128.642 0 10000 FWD DSGN 4096.00030f1a5b6d 128.642
Port-Channel3 128.643 0 10000 FWD DSGN 4096.00030f1a5b6d 128.643
Port-Channel5 128.645 0 10000 FWD DSGN 4096.00030f1a5b6d 128.645
Port-Channel6 128.646 0 10000 FWD DSGN 4096.00030f1a5b6d 128.646
########################### Instance 1 ###########################
Self Bridge Id : 0.00:03:0f:1a:5b:6d
Region Root Id : this switch
Int.RootPathCost : 0
Root Port ID :0
Current port list in Instance 1:
Port-Channel1 Port-Channel2 Port-Channel3 Port-Channel5 Port-Channel6
(Total 5)
56 / 91
神州数码网络有限公司技术支持电话:4008109119
59. 洛阳市第二中医院网络竣工文档
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show version
DCRS-5950-28T-L Device, Compiled on Sep 21 15:21:21 2009
SoftWare Version DCRS-5950-28T-L_6.0.208.0(LITE)
BootRom Version DCRS-5950-28T-L_1.5.3
HardWare Version R02
Copyright (C) 2001-2007 by Digital China Networks Limited.
All rights reserved.
Uptime is 0 weeks, 0 days, 7 hours, 54 minutes.
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show running-config
!
no service password-encryption
!
hostname DCRS-5950-28T-L
sysLocation China
sysContact 800-810-9119
!
username dezyy2012 privilege 15 password 0 dezyy2012
!
!
!
!
!
spanning-tree
spanning-tree mst 0 priority 8192
!
!
!
vlan 1
!
vlan 10
!
vlan 11
!
vlan 12
!
vlan 13
!
vlan 14
!
vlan 20
!
port-group 1
!
port-group 2
!
port-group 3
!
Interface Ethernet1/1
name TO_DCRS-6808E_A_port2/3
no spanning-tree
58 / 91
神州数码网络有限公司技术支持电话:4008109119
60. 洛阳市第二中医院网络竣工文档
switchport mode trunk
port-group 2 mode on
!
Interface Ethernet1/2
name TO_DCRS-6808E-A_port2/4
no spanning-tree
switchport mode trunk
port-group 2 mode on
!
Interface Ethernet1/3
name TO_DCRS-6808E-B_port2/3
no spanning-tree
switchport mode trunk
port-group 3 mode on
!
Interface Ethernet1/4
name TO_DCRS-6808E-B_port2/4
no spanning-tree
switchport mode trunk
port-group 3 mode on
!
Interface Ethernet1/5
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/6
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/7
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/8
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/9
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/10
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/11
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/12
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/13
59 / 91
神州数码网络有限公司技术支持电话:4008109119
61. 洛阳市第二中医院网络竣工文档
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/14
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/15
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/16
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/17
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/18
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/19
name TO_DCFW-5002_port0/2
no spanning-tree
switchport access vlan 14
!
Interface Ethernet1/20
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/21
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/22
name TO_DCFW-5002_port0/5
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/23
name TO_ShengNongHeQianZhiJi
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/24
name TO_HIS_Server
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/25
!
Interface Ethernet1/26
60 / 91
神州数码网络有限公司技术支持电话:4008109119
62. 洛阳市第二中医院网络竣工文档
!
Interface Ethernet1/27
!
Interface Ethernet1/28
!
Interface Port-Channel2
!
Interface Port-Channel3
!
interface Vlan1
ip address 100.100.104.201 255.255.255.192
!
interface Vlan10
!
ip route 0.0.0.0/0 10.10.10.254
!
!
no login
!
end
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show r
radius reload route-map
router-id running-config
DCRS-5950-28T-L#show interface ethernet status
Codes: A-Down - administratively down, a - auto, f - force, G - Gigabit
Interface Link/Protocol Speed Duplex Vlan Type Alias Name
1/1 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E_A
1/2 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-A
1/3 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-B
1/4 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-B
1/5 DOWN/DOWN auto auto 10 G-TX
1/6 DOWN/DOWN auto auto 10 G-TX
1/7 DOWN/DOWN auto auto 10 G-TX
1/8 DOWN/DOWN auto auto 10 G-TX
1/9 DOWN/DOWN auto auto 10 G-TX
1/10 UP/UP a-100M a-FULL 10 G-TX
1/11 DOWN/DOWN auto auto 10 G-TX
1/12 DOWN/DOWN auto auto 10 G-TX
1/13 DOWN/DOWN auto auto 10 G-TX
1/14 DOWN/DOWN auto auto 10 G-TX
1/15 DOWN/DOWN auto auto 10 G-TX
1/16 DOWN/DOWN auto auto 10 G-TX
1/17 DOWN/DOWN auto auto 10 G-TX
1/18 DOWN/DOWN auto auto 10 G-TX
1/19 UP/UP a-1G a-FULL 14 G-TX
TO_DCFW-5002_po
1/20 DOWN/DOWN auto auto 10 G-TX
1/21 DOWN/DOWN auto auto 10 G-Combo
1/22 UP/UP a-1G a-FULL 10 G-Combo:Copper
61 / 91
神州数码网络有限公司技术支持电话:4008109119
63. 洛阳市第二中医院网络竣工文档
TO_DCFW-5002_po
1/23 UP/UP a-1G a-FULL 10 G-Combo:Copper
TO_ShengNongHeQ
1/24 UP/UP a-1G a-FULL 10 G-Combo:Copper TO_HIS_Server
1/25 DOWN/DOWN auto auto 1 XGE GBIC
1/26 DOWN/DOWN auto auto 1 XGE GBIC
1/27 DOWN/DOWN auto auto 1 XGE GBIC
1/28 DOWN/DOWN auto auto 1 XGE GBIC
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show ip interface brief
Index Interface IP-Address Status Protocol
3001 Vlan1 100.100.104.201 up up
3010 Vlan10 unassigned up up
9000 Loopback 127.0.0.1 up up
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show spanning-tree
-- MSTP Bridge Config Info --
Standard : IEEE 802.1s
Bridge MAC : 00:03:0f:16:94:3d
Bridge Times : Max Age 20, Hello Time 2, Forward Delay 15
Force Version: 3
########################### Instance 0 ###########################
Self Bridge Id : 8192 - 00:03:0f:16:94:3d
Root Id : 0.00:03:0f:1a:5b:40
Ext.RootPathCost : 10000
Region Root Id : this switch
Int.RootPathCost : 0
Root Port ID : 128.66
Current port list in Instance 0:
Port-Channel2 Port-Channel3 (Total 2)
PortName ID ExtRPC IntRPC State Role DsgBridge DsgPort
-------------- -------- --------- --------- --- ---- ------------------ -------
Port-Channel2 128.066 0 0 FWD ROOT 0.00030f1a5b40 128.642
Port-Channel3 128.067 0 10000 BLK ALTR 4096.00030f1a5b6d 128.643
DCRS-5950-28T-L#
62 / 91
神州数码网络有限公司技术支持电话:4008109119
64. 洛阳市第二中医院网络竣工文档
7.4 服务器区交换机 DCRS-5950-28T 配置
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show version
DCRS-5950-28T-L Device, Compiled on Sep 21 15:21:21 2009
SoftWare Version DCRS-5950-28T-L_6.0.208.0(LITE)
BootRom Version DCRS-5950-28T-L_1.5.3
HardWare Version R02
Copyright (C) 2001-2007 by Digital China Networks Limited.
All rights reserved.
Uptime is 0 weeks, 0 days, 9 hours, 44 minutes.
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show running-config
!
no service password-encryption
!
hostname DCRS-5950-28T-L
sysLocation China
sysContact 800-810-9119
!
username dezyy2012 privilege 15 password 0 dezyy2012
!
!
!
!
!
spanning-tree
spanning-tree mst 0 priority 8192
!
!
!
vlan 1
!
vlan 10
!
vlan 11
!
vlan 12
!
vlan 13
!
vlan 14
!
vlan 20
!
port-group 1
!
port-group 2
!
port-group 3
63 / 91
神州数码网络有限公司技术支持电话:4008109119
65. 洛阳市第二中医院网络竣工文档
!
Interface Ethernet1/1
name TO_DCRS-6808E_A_port2/3
no spanning-tree
switchport mode trunk
port-group 2 mode on
!
Interface Ethernet1/2
name TO_DCRS-6808E-A_port2/4
no spanning-tree
switchport mode trunk
port-group 2 mode on
!
Interface Ethernet1/3
name TO_DCRS-6808E-B_port2/3
no spanning-tree
switchport mode trunk
port-group 3 mode on
!
Interface Ethernet1/4
name TO_DCRS-6808E-B_port2/4
no spanning-tree
switchport mode trunk
port-group 3 mode on
!
Interface Ethernet1/5
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/6
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/7
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/8
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/9
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/10
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/11
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/12
64 / 91
神州数码网络有限公司技术支持电话:4008109119
66. 洛阳市第二中医院网络竣工文档
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/13
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/14
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/15
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/16
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/17
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/18
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/19
name TO_DCFW-5002_port0/2
no spanning-tree
switchport access vlan 14
!
Interface Ethernet1/20
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/21
name TO_XinNongHe_WAN
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/22
name TO_DCFW-5002_port0/5
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/23
name TO_ShengNongHeQianZhiJi
no spanning-tree
switchport access vlan 10
!
Interface Ethernet1/24
name TO_HIS_Server
no spanning-tree
65 / 91
神州数码网络有限公司技术支持电话:4008109119
67. 洛阳市第二中医院网络竣工文档
switchport access vlan 10
!
Interface Ethernet1/25
!
Interface Ethernet1/26
!
Interface Ethernet1/27
!
Interface Ethernet1/28
!
Interface Port-Channel2
!
Interface Port-Channel3
!
interface Vlan1
ip address 10.10.10.1 255.255.255.0
!
interface Vlan10
!
ip route 0.0.0.0/0 10.10.10.254
!
!
no login
!
end
DCRS-5950-28T-L#
DCRS-5950-28T-L#show interface ethernet status
Codes: A-Down - administratively down, a - auto, f - force, G - Gigabit
Interface Link/Protocol Speed Duplex Vlan Type Alias Name
1/1 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E_A
1/2 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-A
1/3 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-B
1/4 UP/UP a-1G a-FULL trunk G-TX TO_DCRS-6808E-B
1/5 DOWN/DOWN auto auto 10 G-TX
1/6 DOWN/DOWN auto auto 10 G-TX
1/7 DOWN/DOWN auto auto 10 G-TX
1/8 DOWN/DOWN auto auto 10 G-TX
1/9 DOWN/DOWN auto auto 10 G-TX
1/10 DOWN/DOWN auto auto 10 G-TX
1/11 DOWN/DOWN auto auto 10 G-TX
1/12 DOWN/DOWN auto auto 10 G-TX
1/13 DOWN/DOWN auto auto 10 G-TX
1/14 UP/UP a-100M a-FULL 10 G-TX
1/15 DOWN/DOWN auto auto 10 G-TX
1/16 DOWN/DOWN auto auto 10 G-TX
1/17 DOWN/DOWN auto auto 10 G-TX
1/18 DOWN/DOWN auto auto 10 G-TX
1/19 UP/UP a-1G a-FULL 14 G-TX
TO_DCFW-5002_po
1/20 DOWN/DOWN auto auto 10 G-TX
1/21 DOWN/DOWN auto auto 10 G-Combo
TO_XinNongHe_WA
66 / 91
神州数码网络有限公司技术支持电话:4008109119
68. 洛阳市第二中医院网络竣工文档
1/22 UP/UP a-1G a-FULL 10 G-Combo:Copper
TO_DCFW-5002_po
1/23 UP/UP a-1G a-FULL 10 G-Combo:Copper
TO_ShengNongHeQ
1/24 UP/UP a-1G a-FULL 10 G-Combo:Copper TO_HIS_Server
1/25 DOWN/DOWN auto auto 1 XGE GBIC
1/26 DOWN/DOWN auto auto 1 XGE GBIC
1/27 DOWN/DOWN auto auto 1 XGE GBIC
1/28 DOWN/DOWN auto auto 1 XGE GBIC
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show ip interface brief
Index Interface IP-Address Status Protocol
3001 Vlan1 10.10.10.1 up up
3010 Vlan10 unassigned up up
9000 Loopback 127.0.0.1 up up
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#show spanning-tree
-- MSTP Bridge Config Info --
Standard : IEEE 802.1s
Bridge MAC : 00:03:0f:16:94:3d
Bridge Times : Max Age 20, Hello Time 2, Forward Delay 15
Force Version: 3
########################### Instance 0 ###########################
Self Bridge Id : 8192 - 00:03:0f:16:94:3d
Root Id : 0.00:03:0f:1a:5b:40
Ext.RootPathCost : 10000
Region Root Id : this switch
Int.RootPathCost : 0
Root Port ID : 128.66
Current port list in Instance 0:
Port-Channel2 Port-Channel3 (Total 2)
PortName ID ExtRPC IntRPC State Role DsgBridge DsgPort
-------------- -------- --------- --------- --- ---- ------------------ -------
Port-Channel2 128.066 0 0 FWD ROOT 0.00030f1a5b40 128.642
Port-Channel3 128.067 0 10000 BLK ALTR 4096.00030f1a5b6d 128.643
DCRS-5950-28T-L#
DCRS-5950-28T-L#
DCRS-5950-28T-L#wr
Confirm to overwrite current startup-config configuration [Y/N]:y
Write running-config to current startup-config successful
67 / 91
神州数码网络有限公司技术支持电话:4008109119