SlideShare a Scribd company logo
CVF Solar | New Presentation1
Main Header
Sub header
Albuquerque, New Mexico
PV Module Characterization Methods at CFV Solar Test
Lab
Sandia 2014 PV Systems Symposium – Santa Clara, CA
Larry Pratt , Nick Riedel, and the CFV Team
Agenda – Characterization at CFV
• Intro to CFV Solar Test Lab
• Indoor characterization
– Temperature coefficients
– 61853-1 performance matrix
• Outdoor characterization
– Temperature coefficients
– Sandia modeling coefficients
• Industry areas for improvement
Joint Venture of Renowned Standards and Research
Organizations
World renowned solar research
lab with deep technical expertise.
3
Solar innovation lab in Massachusetts
with module prototyping capabilities.
Solar certification is for European and US standards. The CFV Solar Test Laboratory joins CSA and VDE certification
capabilities in PV and creates a globally accepted certification service.
Scientific & Management Advisor to CFV.
PV-module research capabilities
Partner for test-standards development.
Contributing extensive expertise
to design and setup the module
certification lab. Partner for global
PV Test center alliance.
Ideal Test Conditions in Albuquerque, NM
• Highest Solar Irradiance in USA
>> Altitude keeps temperatures low
• National Research Laboratories
>> Sandia, Los Alamos Nat’l labs
• Universities Active in Solar
>> UNM, CNM
• Existing Solar Companies
>> Emcore/Suncore, Sandia,
Array Technologies, Unirac, CST, Affordable Solar, Sacred Power, …
• Political Support
>> NM promotes solar on all levels of government (State, County and City)
• Good Accessibility, Workforce & Living Conditions
>>Albuquerque has excellent scientists, culture and nature
4
h.a.l.m. Flash Solar Simulator
5
• Manufactured by h.a.l.m. Electronik
• Class AAA per IEC 60904-9:
• Spectral match to AM 1.5 G
• Uniformity of irradiance
• Temporal stability of flash
• Integrated thermal chamber (25 – 65 C)
• Irradiance from Xe arc lamp
• 100 - 1100 W/m2
• Controlled by voltage
• Three methods of lamp calibration
• PTB calibrated reference cell (HOQ and KG3)
• Control module tested at ISE Fraunhofer
• Outdoor reference Isc transfer
• Three quadrant capability for DIV
• I-V measurements taken with hysteresis
• Sections used if needed
h.a.l.m. indoor I-V measurement system
PTB calibrated low-uncertainty reference cell
Measurement uncertainty in IV at STC for silicon
• Absolute uncertainty calculated from an algorithm developed at
Fraunhofer ISE, driven by reference cell calibration, non-uniformity, and
spectral mismatch .
– The uncertainty is consistent with the range of values reported in the 2005
module RR sponsored by NREL, most of which was due to the Isc (read
“reference cell”)
– The authors conclude that absolute uncertainty cannot be less than +/- 3%
• Relative uncertainty is calculated from the moving range estimates of the
standard deviation from two check modules that are measured daily.
6
Parameter Absolute [%] Relative [%]
Pmp +/- 2.8 +/- 0.40
Isc +/- 2.3 +/- 0.20
Imp +/- 2.3 +/- 0.25
Voc +/- 0.6 +/- 0.20
Vmp +/- 0.7 +/- 0.25
Indoor Temperature Coefficient Testing
7
• Determined per IEC 61215/61646 §10.4
• Four RTDs place on backsheet
• Module heated from 25 to 65° C
• I-V measurements taken every 2°C
• Considerations:
• Reference cell temperature
• Remains at 25-28°C
• Temperature dwell time before measurement
• 1.5 to 2 minutes
• Module temperature uniformity
• < 1.2° C with help of laminar air flow
• The system is also capable of taking I-V while
cooling the module from 65 to 25° C
• Heating method can be performed faster
• Repeatability of +/- 0.01%/ C for Pmp
• Including effects of cool down and
extended dwell times
Indoor IEC 61853-1 Performance Testing
8
• A given temperature is targeted and then multi-
irradiance measurements are taken.
• Irradiance is changed with lamp voltage.
• A supplemental thermal chamber must be used
for temperatures outside of 25-65 ° C.
• Sections measurements and hysteresis must
be adjusted accordingly.
• Our partner CSE Fraunhofer creates .PAN files
based on these performance data.
• The IEC spectral match rating changes
with irradiance.
• Class A for all irrad. 400-800 nm
• Class B/C > 800nm and < 400 W/m2
• Lower irradiances (ie voltages) shifts
intensity towards λ > 700 nm.
• Spectrum shifts to IR by fractions of a
percent as lamp ages.
Flasher Upgrade for Efficient 61853-1 Testing
9
• ND filters to preserve
spectrum below 600 W/m2
• Improved thermal capacity
for testing 15-75°C
• Installed by Q4 2014 or
sooner
Thermo
generator
Curve Tracer Capacitor Bank
PV
DUT
Xe Arc
Outdoor Temperature Coefficients
• CFV follows the procedures established at SNL – work instructions will be
available later this year
– Shade module, cool to near ambient, insulate backside, set up curve tracer, uncover, sweep
curves while module heats in the sun, regression analysis of translated IV versus Tc-25
• Non-uniform temperature distribution of the cells is a concern
• Temp Coeff for Pmp tends running higher in magnitude by 0.05% to 0.1%
absolute when compared to indoor estimates at CFV
• What is the average cell temperature during indoor/outdoor temp coeff
testing? - See Cliff Hansen et al, PVSC40
• Repeatability of +/- 0.01%/ C for Pmp temperature coefficient
10
Sensor ßVmp (%/C)
BS average -0.48
TC1 -0.52
TC2 -0.42
TC3 -0.42
TC4 -0.55
TC5 -0.49
Performance Model Coefficients
• SAPM
– CFV follows the procedures established at SNL – work instructions will
be available later this year
• Temperature Coefficients
• Angle of Incidence
• Electrical performance modelling (SAND2004-3535)
• .PAN file generation in partnership with CSE Fraunhofer
– Multi-Irradiance and temperature data provided by CFV
– .PAN file generation by CSE Fraunhofer
– Recommend three representative modules for full test matrix
11
Industry areas for improvement
• Reference cell calibration
• 2.1 and 2.3% delta on outdoor ref cells measured at SNL and ISE
• 2% delta on indoor ref cell measured at PTB and NREL
• US calibration values lower in all three cases
• Temperature coefficient delta of 0.05% to 0.1% absolute
• Results in a 1% to 2% prediction error at 45 C cell temperature
• Combined effect of RC and temp coeff could be as high as 4%
• CEC temp coefficient limits are not consistent with those reported in the
Yingli RR
• Why specify IEC 60904-3 spectrum for low irradiance testing?
• Is this likely in the real world?
• What’s a reasonable alternative, given the labs can’t easily adjust spectrum
12
Contact:
CFV Solar Test Laboratory, Inc.
5600-A University Blvd SE
Albuquerque, NM 87106
Martin Plass
Senior VP & General Manager
Martin.Plass@cfvsolar.com
+1 (505) 998-0102
or
Customer Service at
Info@CFVSolar.com
+1 (505) 998-0100
13
Thank you !

More Related Content

What's hot

Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-enSn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
Wei Liu
 
Flame Stabilization Techniques
Flame Stabilization TechniquesFlame Stabilization Techniques
Flame Stabilization Techniques
ROSHAN SAH
 
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
Sandia National Laboratories: Energy & Climate: Renewables
 
Eco cooling
Eco cooling Eco cooling
Eco cooling
JISC RSC Eastern
 
A practical capacitive type co2 sensor using ce o2
A practical capacitive type co2 sensor using ce o2A practical capacitive type co2 sensor using ce o2
A practical capacitive type co2 sensor using ce o2
Sherry Huang
 
About us
About usAbout us
mwpc gas gain report
mwpc gas gain reportmwpc gas gain report
mwpc gas gain report
Andrew Schick
 
61 boyd high_speed_monitoring
61 boyd high_speed_monitoring61 boyd high_speed_monitoring
Thermal energy agenda and bellwork
Thermal energy   agenda and bellworkThermal energy   agenda and bellwork
Thermal energy agenda and bellworksbarkanic
 
Zero super-heat control
Zero super-heat control Zero super-heat control
Zero super-heat control
ATMOsphere Conferences & Events
 
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
ARAaus
 
Tesi master Ram Khrishna Thakur
Tesi master Ram Khrishna ThakurTesi master Ram Khrishna Thakur
Tesi master Ram Khrishna Thakur
thinfilmsworkshop
 
Contact temperature sensor calibration
Contact temperature sensor calibrationContact temperature sensor calibration
Contact temperature sensor calibration
Tempsens Instruments
 
Zorb-Science, EMF and SAR Tests, www.TheZorb.com
Zorb-Science, EMF and SAR Tests, www.TheZorb.comZorb-Science, EMF and SAR Tests, www.TheZorb.com
Zorb-Science, EMF and SAR Tests, www.TheZorb.comDavid Hairabedian
 
Technology at work in your facility hvac pre-cooling
Technology at work in your facility   hvac pre-coolingTechnology at work in your facility   hvac pre-cooling
Technology at work in your facility hvac pre-coolingTNenergy
 
USU AFRL Presentation usu local present
USU AFRL Presentation usu local presentUSU AFRL Presentation usu local present
USU AFRL Presentation usu local presentZachery Pope
 
IRJET - Control and Analyze of TCPTF
IRJET -  	  Control and Analyze of TCPTFIRJET -  	  Control and Analyze of TCPTF
IRJET - Control and Analyze of TCPTF
IRJET Journal
 
A Framework for Probabilistic Building Energy Modeling
A Framework for Probabilistic Building Energy ModelingA Framework for Probabilistic Building Energy Modeling
A Framework for Probabilistic Building Energy Modeling
Lukas Lundström
 

What's hot (20)

Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-enSn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
Sn 43369-benefits-gf-aa-to-icp-ms-sn43369-en
 
Flame Stabilization Techniques
Flame Stabilization TechniquesFlame Stabilization Techniques
Flame Stabilization Techniques
 
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
65 sutterlueti using_advanced_pv_and_bo_s_modelling_and_algorithms_to_optimiz...
 
Eco cooling
Eco cooling Eco cooling
Eco cooling
 
A practical capacitive type co2 sensor using ce o2
A practical capacitive type co2 sensor using ce o2A practical capacitive type co2 sensor using ce o2
A practical capacitive type co2 sensor using ce o2
 
RAMSPosterJorge
RAMSPosterJorgeRAMSPosterJorge
RAMSPosterJorge
 
About us
About usAbout us
About us
 
mwpc gas gain report
mwpc gas gain reportmwpc gas gain report
mwpc gas gain report
 
61 boyd high_speed_monitoring
61 boyd high_speed_monitoring61 boyd high_speed_monitoring
61 boyd high_speed_monitoring
 
Thermal energy agenda and bellwork
Thermal energy   agenda and bellworkThermal energy   agenda and bellwork
Thermal energy agenda and bellwork
 
Zero super-heat control
Zero super-heat control Zero super-heat control
Zero super-heat control
 
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
Sam czyczelis emscap presentation hvacr energy effeciency seminar 2016 format...
 
P1
P1P1
P1
 
Tesi master Ram Khrishna Thakur
Tesi master Ram Khrishna ThakurTesi master Ram Khrishna Thakur
Tesi master Ram Khrishna Thakur
 
Contact temperature sensor calibration
Contact temperature sensor calibrationContact temperature sensor calibration
Contact temperature sensor calibration
 
Zorb-Science, EMF and SAR Tests, www.TheZorb.com
Zorb-Science, EMF and SAR Tests, www.TheZorb.comZorb-Science, EMF and SAR Tests, www.TheZorb.com
Zorb-Science, EMF and SAR Tests, www.TheZorb.com
 
Technology at work in your facility hvac pre-cooling
Technology at work in your facility   hvac pre-coolingTechnology at work in your facility   hvac pre-cooling
Technology at work in your facility hvac pre-cooling
 
USU AFRL Presentation usu local present
USU AFRL Presentation usu local presentUSU AFRL Presentation usu local present
USU AFRL Presentation usu local present
 
IRJET - Control and Analyze of TCPTF
IRJET -  	  Control and Analyze of TCPTFIRJET -  	  Control and Analyze of TCPTF
IRJET - Control and Analyze of TCPTF
 
A Framework for Probabilistic Building Energy Modeling
A Framework for Probabilistic Building Energy ModelingA Framework for Probabilistic Building Energy Modeling
A Framework for Probabilistic Building Energy Modeling
 

Similar to PV Module Characterization Methods at CFV Solar Test Laboratory

Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
Leonardo ENERGY
 
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
Kyumin Lee
 
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
Sandia National Laboratories: Energy & Climate: Renewables
 
Principles and Practices of Traceability and Calibration
Principles and Practices of Traceability and CalibrationPrinciples and Practices of Traceability and Calibration
Principles and Practices of Traceability and Calibration
Jasmin NUHIC
 
05 2017 03_ralph_gottschalg_standardsbodyperspective
05 2017 03_ralph_gottschalg_standardsbodyperspective05 2017 03_ralph_gottschalg_standardsbodyperspective
05 2017 03_ralph_gottschalg_standardsbodyperspective
Sandia National Laboratories: Energy & Climate: Renewables
 
qualification of FTIR and DSC
qualification of FTIR and DSCqualification of FTIR and DSC
qualification of FTIR and DSC
Amansharma1378
 
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
Sandia National Laboratories: Energy & Climate: Renewables
 
AFRL_MAET_Presentation
AFRL_MAET_PresentationAFRL_MAET_Presentation
AFRL_MAET_PresentationAanish Sikora
 
63 matthiss comparison_of_pv_system_and_irradiation_models
63 matthiss comparison_of_pv_system_and_irradiation_models63 matthiss comparison_of_pv_system_and_irradiation_models
63 matthiss comparison_of_pv_system_and_irradiation_models
Sandia National Laboratories: Energy & Climate: Renewables
 
Qualification of high performance liquid chromatography
Qualification of high performance liquid chromatographyQualification of high performance liquid chromatography
Qualification of high performance liquid chromatography
srikrupa institute of pharmaceutical analysis
 
Retrocommissioning of Existing Buildings
Retrocommissioning of Existing BuildingsRetrocommissioning of Existing Buildings
Retrocommissioning of Existing Buildings
WIGreenBuilding
 
Keith_Coulson_poster
Keith_Coulson_posterKeith_Coulson_poster
Keith_Coulson_posterKeith Coulson
 
Central power research institute report
Central power research institute reportCentral power research institute report
Central power research institute report
Mayur Dhanaji Rane
 
Qualification of analytical instruments
Qualification of analytical instruments Qualification of analytical instruments
Qualification of analytical instruments
PUNEET NIRMAL
 
Integrated Detector Electronics (IDEAS) ASIC product update
Integrated Detector Electronics (IDEAS) ASIC product updateIntegrated Detector Electronics (IDEAS) ASIC product update
Integrated Detector Electronics (IDEAS) ASIC product update
Gunnar Maehlum
 
Production planning for distributed district heating with JModelica.org
Production planning for distributed district heating with JModelica.orgProduction planning for distributed district heating with JModelica.org
Production planning for distributed district heating with JModelica.org
Modelon
 
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
Clinton Smith
 
How to calibrate an ir thermometer, frank liebmann, 2013 05-07
How to calibrate an ir thermometer, frank liebmann, 2013 05-07How to calibrate an ir thermometer, frank liebmann, 2013 05-07
How to calibrate an ir thermometer, frank liebmann, 2013 05-07Jesus Enrique Oliva Salazar
 

Similar to PV Module Characterization Methods at CFV Solar Test Laboratory (20)

Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
Photovoltaic Module Energy Yield Measurements: Existing Approaches and Best P...
 
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
PAN Files from IEC 61853-1 Test Data: Why Using Datasheet I-V Values is a Bad...
 
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
2014 PV Performance Modeling Workshop: Toward Reliable Module Temperature Mea...
 
Principles and Practices of Traceability and Calibration
Principles and Practices of Traceability and CalibrationPrinciples and Practices of Traceability and Calibration
Principles and Practices of Traceability and Calibration
 
05 2017 03_ralph_gottschalg_standardsbodyperspective
05 2017 03_ralph_gottschalg_standardsbodyperspective05 2017 03_ralph_gottschalg_standardsbodyperspective
05 2017 03_ralph_gottschalg_standardsbodyperspective
 
qualification of FTIR and DSC
qualification of FTIR and DSCqualification of FTIR and DSC
qualification of FTIR and DSC
 
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
2014 PV Performance Modeling Workshop: Results from Flash Testing at Multiple...
 
AFRL_MAET_Presentation
AFRL_MAET_PresentationAFRL_MAET_Presentation
AFRL_MAET_Presentation
 
63 matthiss comparison_of_pv_system_and_irradiation_models
63 matthiss comparison_of_pv_system_and_irradiation_models63 matthiss comparison_of_pv_system_and_irradiation_models
63 matthiss comparison_of_pv_system_and_irradiation_models
 
Qualification of high performance liquid chromatography
Qualification of high performance liquid chromatographyQualification of high performance liquid chromatography
Qualification of high performance liquid chromatography
 
Retrocommissioning of Existing Buildings
Retrocommissioning of Existing BuildingsRetrocommissioning of Existing Buildings
Retrocommissioning of Existing Buildings
 
Keith_Coulson_poster
Keith_Coulson_posterKeith_Coulson_poster
Keith_Coulson_poster
 
Central power research institute report
Central power research institute reportCentral power research institute report
Central power research institute report
 
Jagadeesh_Resume
Jagadeesh_ResumeJagadeesh_Resume
Jagadeesh_Resume
 
Firth Bendau Poster
Firth Bendau PosterFirth Bendau Poster
Firth Bendau Poster
 
Qualification of analytical instruments
Qualification of analytical instruments Qualification of analytical instruments
Qualification of analytical instruments
 
Integrated Detector Electronics (IDEAS) ASIC product update
Integrated Detector Electronics (IDEAS) ASIC product updateIntegrated Detector Electronics (IDEAS) ASIC product update
Integrated Detector Electronics (IDEAS) ASIC product update
 
Production planning for distributed district heating with JModelica.org
Production planning for distributed district heating with JModelica.orgProduction planning for distributed district heating with JModelica.org
Production planning for distributed district heating with JModelica.org
 
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
A rotational reference cell for high-accuracy real-time spectroscopic trace-g...
 
How to calibrate an ir thermometer, frank liebmann, 2013 05-07
How to calibrate an ir thermometer, frank liebmann, 2013 05-07How to calibrate an ir thermometer, frank liebmann, 2013 05-07
How to calibrate an ir thermometer, frank liebmann, 2013 05-07
 

Recently uploaded

一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
ydteq
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
MdTanvirMahtab2
 
Understanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine LearningUnderstanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine Learning
SUTEJAS
 
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTSHeap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Soumen Santra
 
MCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdfMCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdf
Osamah Alsalih
 
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
ssuser7dcef0
 
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
zwunae
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
Victor Morales
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
manasideore6
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
ClaraZara1
 
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
thanhdowork
 
DfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributionsDfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributions
gestioneergodomus
 
Technical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prismsTechnical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prisms
heavyhaig
 
Online aptitude test management system project report.pdf
Online aptitude test management system project report.pdfOnline aptitude test management system project report.pdf
Online aptitude test management system project report.pdf
Kamal Acharya
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
Amil Baba Dawood bangali
 
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
bakpo1
 
Building Electrical System Design & Installation
Building Electrical System Design & InstallationBuilding Electrical System Design & Installation
Building Electrical System Design & Installation
symbo111
 
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming PipelinesHarnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Christina Lin
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
fxintegritypublishin
 
Fundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptxFundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptx
manasideore6
 

Recently uploaded (20)

一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
 
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)
 
Understanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine LearningUnderstanding Inductive Bias in Machine Learning
Understanding Inductive Bias in Machine Learning
 
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTSHeap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
Heap Sort (SS).ppt FOR ENGINEERING GRADUATES, BCA, MCA, MTECH, BSC STUDENTS
 
MCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdfMCQ Soil mechanics questions (Soil shear strength).pdf
MCQ Soil mechanics questions (Soil shear strength).pdf
 
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...
 
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
一比一原版(UMich毕业证)密歇根大学|安娜堡分校毕业证成绩单专业办理
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
 
Fundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptxFundamentals of Electric Drives and its applications.pptx
Fundamentals of Electric Drives and its applications.pptx
 
6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)6th International Conference on Machine Learning & Applications (CMLA 2024)
6th International Conference on Machine Learning & Applications (CMLA 2024)
 
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
RAT: Retrieval Augmented Thoughts Elicit Context-Aware Reasoning in Long-Hori...
 
DfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributionsDfMAy 2024 - key insights and contributions
DfMAy 2024 - key insights and contributions
 
Technical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prismsTechnical Drawings introduction to drawing of prisms
Technical Drawings introduction to drawing of prisms
 
Online aptitude test management system project report.pdf
Online aptitude test management system project report.pdfOnline aptitude test management system project report.pdf
Online aptitude test management system project report.pdf
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
 
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
一比一原版(SFU毕业证)西蒙菲莎大学毕业证成绩单如何办理
 
Building Electrical System Design & Installation
Building Electrical System Design & InstallationBuilding Electrical System Design & Installation
Building Electrical System Design & Installation
 
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming PipelinesHarnessing WebAssembly for Real-time Stateless Streaming Pipelines
Harnessing WebAssembly for Real-time Stateless Streaming Pipelines
 
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdfHybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdf
 
Fundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptxFundamentals of Induction Motor Drives.pptx
Fundamentals of Induction Motor Drives.pptx
 

PV Module Characterization Methods at CFV Solar Test Laboratory

  • 1. CVF Solar | New Presentation1 Main Header Sub header Albuquerque, New Mexico PV Module Characterization Methods at CFV Solar Test Lab Sandia 2014 PV Systems Symposium – Santa Clara, CA Larry Pratt , Nick Riedel, and the CFV Team
  • 2. Agenda – Characterization at CFV • Intro to CFV Solar Test Lab • Indoor characterization – Temperature coefficients – 61853-1 performance matrix • Outdoor characterization – Temperature coefficients – Sandia modeling coefficients • Industry areas for improvement
  • 3. Joint Venture of Renowned Standards and Research Organizations World renowned solar research lab with deep technical expertise. 3 Solar innovation lab in Massachusetts with module prototyping capabilities. Solar certification is for European and US standards. The CFV Solar Test Laboratory joins CSA and VDE certification capabilities in PV and creates a globally accepted certification service. Scientific & Management Advisor to CFV. PV-module research capabilities Partner for test-standards development. Contributing extensive expertise to design and setup the module certification lab. Partner for global PV Test center alliance.
  • 4. Ideal Test Conditions in Albuquerque, NM • Highest Solar Irradiance in USA >> Altitude keeps temperatures low • National Research Laboratories >> Sandia, Los Alamos Nat’l labs • Universities Active in Solar >> UNM, CNM • Existing Solar Companies >> Emcore/Suncore, Sandia, Array Technologies, Unirac, CST, Affordable Solar, Sacred Power, … • Political Support >> NM promotes solar on all levels of government (State, County and City) • Good Accessibility, Workforce & Living Conditions >>Albuquerque has excellent scientists, culture and nature 4
  • 5. h.a.l.m. Flash Solar Simulator 5 • Manufactured by h.a.l.m. Electronik • Class AAA per IEC 60904-9: • Spectral match to AM 1.5 G • Uniformity of irradiance • Temporal stability of flash • Integrated thermal chamber (25 – 65 C) • Irradiance from Xe arc lamp • 100 - 1100 W/m2 • Controlled by voltage • Three methods of lamp calibration • PTB calibrated reference cell (HOQ and KG3) • Control module tested at ISE Fraunhofer • Outdoor reference Isc transfer • Three quadrant capability for DIV • I-V measurements taken with hysteresis • Sections used if needed h.a.l.m. indoor I-V measurement system PTB calibrated low-uncertainty reference cell
  • 6. Measurement uncertainty in IV at STC for silicon • Absolute uncertainty calculated from an algorithm developed at Fraunhofer ISE, driven by reference cell calibration, non-uniformity, and spectral mismatch . – The uncertainty is consistent with the range of values reported in the 2005 module RR sponsored by NREL, most of which was due to the Isc (read “reference cell”) – The authors conclude that absolute uncertainty cannot be less than +/- 3% • Relative uncertainty is calculated from the moving range estimates of the standard deviation from two check modules that are measured daily. 6 Parameter Absolute [%] Relative [%] Pmp +/- 2.8 +/- 0.40 Isc +/- 2.3 +/- 0.20 Imp +/- 2.3 +/- 0.25 Voc +/- 0.6 +/- 0.20 Vmp +/- 0.7 +/- 0.25
  • 7. Indoor Temperature Coefficient Testing 7 • Determined per IEC 61215/61646 §10.4 • Four RTDs place on backsheet • Module heated from 25 to 65° C • I-V measurements taken every 2°C • Considerations: • Reference cell temperature • Remains at 25-28°C • Temperature dwell time before measurement • 1.5 to 2 minutes • Module temperature uniformity • < 1.2° C with help of laminar air flow • The system is also capable of taking I-V while cooling the module from 65 to 25° C • Heating method can be performed faster • Repeatability of +/- 0.01%/ C for Pmp • Including effects of cool down and extended dwell times
  • 8. Indoor IEC 61853-1 Performance Testing 8 • A given temperature is targeted and then multi- irradiance measurements are taken. • Irradiance is changed with lamp voltage. • A supplemental thermal chamber must be used for temperatures outside of 25-65 ° C. • Sections measurements and hysteresis must be adjusted accordingly. • Our partner CSE Fraunhofer creates .PAN files based on these performance data. • The IEC spectral match rating changes with irradiance. • Class A for all irrad. 400-800 nm • Class B/C > 800nm and < 400 W/m2 • Lower irradiances (ie voltages) shifts intensity towards λ > 700 nm. • Spectrum shifts to IR by fractions of a percent as lamp ages.
  • 9. Flasher Upgrade for Efficient 61853-1 Testing 9 • ND filters to preserve spectrum below 600 W/m2 • Improved thermal capacity for testing 15-75°C • Installed by Q4 2014 or sooner Thermo generator Curve Tracer Capacitor Bank PV DUT Xe Arc
  • 10. Outdoor Temperature Coefficients • CFV follows the procedures established at SNL – work instructions will be available later this year – Shade module, cool to near ambient, insulate backside, set up curve tracer, uncover, sweep curves while module heats in the sun, regression analysis of translated IV versus Tc-25 • Non-uniform temperature distribution of the cells is a concern • Temp Coeff for Pmp tends running higher in magnitude by 0.05% to 0.1% absolute when compared to indoor estimates at CFV • What is the average cell temperature during indoor/outdoor temp coeff testing? - See Cliff Hansen et al, PVSC40 • Repeatability of +/- 0.01%/ C for Pmp temperature coefficient 10 Sensor ßVmp (%/C) BS average -0.48 TC1 -0.52 TC2 -0.42 TC3 -0.42 TC4 -0.55 TC5 -0.49
  • 11. Performance Model Coefficients • SAPM – CFV follows the procedures established at SNL – work instructions will be available later this year • Temperature Coefficients • Angle of Incidence • Electrical performance modelling (SAND2004-3535) • .PAN file generation in partnership with CSE Fraunhofer – Multi-Irradiance and temperature data provided by CFV – .PAN file generation by CSE Fraunhofer – Recommend three representative modules for full test matrix 11
  • 12. Industry areas for improvement • Reference cell calibration • 2.1 and 2.3% delta on outdoor ref cells measured at SNL and ISE • 2% delta on indoor ref cell measured at PTB and NREL • US calibration values lower in all three cases • Temperature coefficient delta of 0.05% to 0.1% absolute • Results in a 1% to 2% prediction error at 45 C cell temperature • Combined effect of RC and temp coeff could be as high as 4% • CEC temp coefficient limits are not consistent with those reported in the Yingli RR • Why specify IEC 60904-3 spectrum for low irradiance testing? • Is this likely in the real world? • What’s a reasonable alternative, given the labs can’t easily adjust spectrum 12
  • 13. Contact: CFV Solar Test Laboratory, Inc. 5600-A University Blvd SE Albuquerque, NM 87106 Martin Plass Senior VP & General Manager Martin.Plass@cfvsolar.com +1 (505) 998-0102 or Customer Service at Info@CFVSolar.com +1 (505) 998-0100 13 Thank you !

Editor's Notes

  1. Need new FH-CSE picture from 5 Channel Center
  2. Font?
  3. Animate bullet points? Mention that we have compared to a 5 minute temperature dwell time with excellent agreement.
  4. MM factors changed by &amp;lt;0.7% after the new lamp was installed (KG3 was the worst case)
  5. Whole matrix without chambers ~3hrs
  6. Remember TC location. Lower temp results in higher temp coeff.