Revanth Technologies 
B1, 3rd Floor, Eureka Court, Near Image Hospital, Ameerpet, Hyderabad. 
Ph : 9290971883, 9247461324, Email ID : revanthonlineenquiry@gmail.com 
www.revanthtechnologies.in 
SAN Online Training 
Course Duration – 30 hrs 
Prerequisites 
Technical Understanding of Network Concepts, UNIX, RAID etc 
SAN Fundamentals 
• SNIA 
• Introduction to Storage Networking - SNIA 
• Direct Attached Storage (DAS) 
• Network Attached Storage (NAS) 
• Storage Area Network (SAN) 
• Protocols 
• SCSI 
• FCP 
• FCIP 
• IFCP 
• ISCSI 
• Virtualization 
• Traditional JBOD 
• What is a RAID 
• RAID Controllers 
• Storage Subsystems 
• Information Lifecycle Management (ILM) 
• HSM 
• VTL 
• Data Movers 
• Business Continuity 
• What is RTO 
• What is RPO
SAN (Brocade) & Storage (Clariion & Symmetrix) Administration 
• Fiber Channels – Brocade FC 100 
• Why Fibre Channel? 
• FC Theory fundamentals & Introduction. 
• FC Layers & Related Components. 
• FC Topologies, Terminology & Addressing. 
• Expected FC Behavior. 
• FC Theory fundamentals summary. 
• Brocade Switches & Management 
• SilkWorm Introduction. 
• Introduction to Hardware & Software Products. 
• Installation and Setup. 
• Installation of new switches. 
• Firmware downloads & Configuration Uploads 
• User Accounts and Password Behaviors. 
• Fabric-wide Settings vs. Local Switch Settings 
• Core PID & Fabric OS Commands. 
• Brocade Zoning. 
• Advantages of Zoning. 
• Zoning Types 
• Soft Zoning 
• Hard Zoning 
• Mixed Zoning 
• Networking. 
• Fabric Designs 
• FSPF – Fabric Shortest Path First. 
• Trunking. 
• DLS 
• MPR
• IFCP 
• EMC CLARiiON Host Integration & Management 
• Introduction - Course Overview 
• Review of Pre-Requisite Modules. 
• CLARiiON Architecture. 
• CLARiiON Software features. 
• CLARRIION Management Utilities. 
• Navisphere Manager. 
• Management Menu Choices. 
• Managing the Storage System. 
• Managing RAID groups. 
• Managing LUNs. 
SAN (Brocade) & Storage (Clariion & Symmetrix) Administration 
• Solaris Integration 
• Access Logix 
• Defining Access Logix. 
• Access Logix Operation. 
• Host Registration. 
• Managing Storage Groups with Navisphere Manager. 
• Advanced LUN Management 
• Advanced LUN Concepts. 
• Meta LUNs. 
• LUN Migration 
• PowerPath 
• Introduction 
• Defining PowerPath Terminology. 
• PowerPath Operation. 
• Zoning for PowerPath. 
• PowerPath Administration.
• PowerPath Functionality. 
• SnapView Snapshots 
• SnapView Snapshots Overview. 
• SnapView Operation. 
• Reserved LUN Pool Configuration. 
• SnapView GUI Administration. 
• SnapView Host Interaction. 
• Snap View Clones 
• Clone Overview. 
• Clone Operations. 
• Clone Administration. 
• Mirror View Configuration & Management 
• Functionality of MirrowView/S and MirrowView/A. 
• Mirror View Configuration. 
• Fracture Log and Write Intent 
• Log Operation. 
• Mirror View Administration 
• Symmetrix Foundation 
• Symmetrix Inside - Logical view 
• FA, DA and Cache 
• EMC physical disk and Symmetrix device (logical volume) 
• Read Hit/Miss, Write Hit/Miss 
• EMC Symmetrix Solution Enabler 
SAN (Brocade) & Storage (Clariion & Symmetrix) Administration 
• Symmetrix/DMX Configuration Manager 
• Host HBA installation and configuration 
• Solution Enabler to explore Symmetrix internals. 
• How many FA, DA and cache & how many physical disks installed, why? 
• How the logical volumes are formed from physical disks?
• How are the logical volumes mapped to FAs? 
• How I/O are performed in Storage Arrays 
• Configuration Manager 
• Configuration Management Fundamentals 
• Creating and Deleting of Hyper Volumes 
• Mapping and Unmapping of Devices 
• Managing Meta Devices 
• Symmetrix DMX Series Director Pairing 
• SRDF R1/R2 Volumes 
• Configuration Manager with SRDF 
• Symmetrix Command Line Interface 
• Time Finder configuration and Management 
• Symmetrix TimeFinder 
• TimeFinder Mirror/BCV 
• TimeFinder/Clone 
• TimeFinder/Snap 
• Zoning and LunMasking to assign STD to production host 
• Symconfigure to make BCV and map BCV to FA 
• BCV operations (Query/Establish/split) 
• Zoning and LunMasking to assign BCV to host 
• Split BCV and STD 
• Mount STD and BCV using Lun-masking 
• Consistent split 
• SRDF configuration and Management 
• Symmetrix TimeFinder Review 
• Symmetrix SRDF 
• SRDF operations 
• Symmetrix SRDF failover and failback 
• Symconfigure to make R1/R2 and map R2 to FA 
• RDF operations (Establish/split)
• Mount STD and Failover to DR 
• Zoning and LunMasking to Mount R2 on DR hosts 
• Modify R2 and Failback to R1 site 
• SRDF restore from R2 to R1

SAN Online Training

  • 1.
    Revanth Technologies B1,3rd Floor, Eureka Court, Near Image Hospital, Ameerpet, Hyderabad. Ph : 9290971883, 9247461324, Email ID : revanthonlineenquiry@gmail.com www.revanthtechnologies.in SAN Online Training Course Duration – 30 hrs Prerequisites Technical Understanding of Network Concepts, UNIX, RAID etc SAN Fundamentals • SNIA • Introduction to Storage Networking - SNIA • Direct Attached Storage (DAS) • Network Attached Storage (NAS) • Storage Area Network (SAN) • Protocols • SCSI • FCP • FCIP • IFCP • ISCSI • Virtualization • Traditional JBOD • What is a RAID • RAID Controllers • Storage Subsystems • Information Lifecycle Management (ILM) • HSM • VTL • Data Movers • Business Continuity • What is RTO • What is RPO
  • 2.
    SAN (Brocade) &Storage (Clariion & Symmetrix) Administration • Fiber Channels – Brocade FC 100 • Why Fibre Channel? • FC Theory fundamentals & Introduction. • FC Layers & Related Components. • FC Topologies, Terminology & Addressing. • Expected FC Behavior. • FC Theory fundamentals summary. • Brocade Switches & Management • SilkWorm Introduction. • Introduction to Hardware & Software Products. • Installation and Setup. • Installation of new switches. • Firmware downloads & Configuration Uploads • User Accounts and Password Behaviors. • Fabric-wide Settings vs. Local Switch Settings • Core PID & Fabric OS Commands. • Brocade Zoning. • Advantages of Zoning. • Zoning Types • Soft Zoning • Hard Zoning • Mixed Zoning • Networking. • Fabric Designs • FSPF – Fabric Shortest Path First. • Trunking. • DLS • MPR
  • 3.
    • IFCP •EMC CLARiiON Host Integration & Management • Introduction - Course Overview • Review of Pre-Requisite Modules. • CLARiiON Architecture. • CLARiiON Software features. • CLARRIION Management Utilities. • Navisphere Manager. • Management Menu Choices. • Managing the Storage System. • Managing RAID groups. • Managing LUNs. SAN (Brocade) & Storage (Clariion & Symmetrix) Administration • Solaris Integration • Access Logix • Defining Access Logix. • Access Logix Operation. • Host Registration. • Managing Storage Groups with Navisphere Manager. • Advanced LUN Management • Advanced LUN Concepts. • Meta LUNs. • LUN Migration • PowerPath • Introduction • Defining PowerPath Terminology. • PowerPath Operation. • Zoning for PowerPath. • PowerPath Administration.
  • 4.
    • PowerPath Functionality. • SnapView Snapshots • SnapView Snapshots Overview. • SnapView Operation. • Reserved LUN Pool Configuration. • SnapView GUI Administration. • SnapView Host Interaction. • Snap View Clones • Clone Overview. • Clone Operations. • Clone Administration. • Mirror View Configuration & Management • Functionality of MirrowView/S and MirrowView/A. • Mirror View Configuration. • Fracture Log and Write Intent • Log Operation. • Mirror View Administration • Symmetrix Foundation • Symmetrix Inside - Logical view • FA, DA and Cache • EMC physical disk and Symmetrix device (logical volume) • Read Hit/Miss, Write Hit/Miss • EMC Symmetrix Solution Enabler SAN (Brocade) & Storage (Clariion & Symmetrix) Administration • Symmetrix/DMX Configuration Manager • Host HBA installation and configuration • Solution Enabler to explore Symmetrix internals. • How many FA, DA and cache & how many physical disks installed, why? • How the logical volumes are formed from physical disks?
  • 5.
    • How arethe logical volumes mapped to FAs? • How I/O are performed in Storage Arrays • Configuration Manager • Configuration Management Fundamentals • Creating and Deleting of Hyper Volumes • Mapping and Unmapping of Devices • Managing Meta Devices • Symmetrix DMX Series Director Pairing • SRDF R1/R2 Volumes • Configuration Manager with SRDF • Symmetrix Command Line Interface • Time Finder configuration and Management • Symmetrix TimeFinder • TimeFinder Mirror/BCV • TimeFinder/Clone • TimeFinder/Snap • Zoning and LunMasking to assign STD to production host • Symconfigure to make BCV and map BCV to FA • BCV operations (Query/Establish/split) • Zoning and LunMasking to assign BCV to host • Split BCV and STD • Mount STD and BCV using Lun-masking • Consistent split • SRDF configuration and Management • Symmetrix TimeFinder Review • Symmetrix SRDF • SRDF operations • Symmetrix SRDF failover and failback • Symconfigure to make R1/R2 and map R2 to FA • RDF operations (Establish/split)
  • 6.
    • Mount STDand Failover to DR • Zoning and LunMasking to Mount R2 on DR hosts • Modify R2 and Failback to R1 site • SRDF restore from R2 to R1