2 Rittal Hygienic Design
The Rittal Hygienic Design for food safety is based on:
● Machinery Directive
(Directive 98/37/EC)
Food Machinery
section, Appendix 1,
point 2.1 (to be
replaced by
2006/42/EC)
● DIN EN 1672-2:2005
Food machinery –
General design princi-
ples – Part 2: Hygiene
requirements
● DIN EN ISO 14 159
Machine safety –
Hygiene requirements
pertaining to the
design of machinery
● Document 13 EHEDG-
Guideline to the
hygienic design of
apparatus for open
processes, prepared in
collaboration with 3-A
and NSF International
Become cleaner better and more productive –
with Rittal Hygienic Design.
Benefits compared with conventional enclosures:
● Higher productivity through greater system availability.
● Reducing the amount of cleaning required (faster
cleaning, reduced energy requirements, reduced use of
chemicals).
● Superior product quality and greater durability by
reducing the contamination risk, which in turn helps to
avoid production losses.
● Improved protection for both consumers and employees.
HDRittal
Hygienic Design
3Rittal Hygienic Design
Cleaning and disinfection
Hygiene checks and the
monitoring of cleaning
processes have revealed that
the use of high pressure
washing harbours the risk of
organic contaminants (fats or
proteins) entering niches and
being more widely distributed.
For this reason, pressures are
being significantly reduced.
Decide for yourself what is
important:
● High pressure-resistant
design
A labyrinth in front of the seal
or multiple screw-fastening of
the lid or door to the enclo-
sure, to enable the use of
high pressure hosing of up to
120 bar, whether static or
manual.
As well as hampering servic-
ing, multiple screw-fastening
also harbours additional
hygiene risks resulting from
incorrectly tightened screws
or damaged seals.
● Hygienic design
The new Hygienic Design
avoids the hollows and dead
spaces found in labyrinths for
high pressure applications.
RITTAL OFFERS THE “KEY” TO
OPTIMUM HYGIENE FOR ALL
SECTORS!
The completely new lock insert is synonymous with the consistency
of Hygienic Design from Rittal. Featuring a high protection category,
it has nowhere for micro-organisms to hide, making cleaning easy.
The same is true of the entire new product line, in every respect.
Rittal Hygienic Design reduces the risk of contamination and
significantly increases your productivity.
Meat, poultry, fish,
delicatessen products,
ready meals
Beverages, fruit and
vegetables
Milk processing, cheese
and dairy product
manufacturing
Baked goods and
confectionery
4 Rittal Hygienic Design
Make existing plant more hygienic. This saves
time with cleaning and disinfection, i.e. down-
time is reduced, or plant productivity is
increased, provided ...
Optimise existing machines and systems
The growing incidence of food poisoning and food product
recalls caused by microbial, physical or chemical contami-
nation underscore the need for reliable hygiene standards.
... the wall-mounted devices
and enclosures are installed
at a distance for cleaning
purposes. With the HD wall
spacer bracket.
… enclosures with cable
entry from below are
mounted on the new HD
supporting structure rather
than on a base/plinth or a
mounting angle frame.
5Rittal Hygienic Design
... the new HD levelling feet
eliminate the need for
adjustment with external
threads.
... the polyamide or brass
cable entry with external
thread is replaced by the
new HD stainless steel
cable gland.
... the standard flat roofs
in TS 8 enclosures are
replaced by a sloped
attachment.
... terminal boxes (Premium-
KL IP 69K), used e.g. as
socket outlets, are mounted
on the wall at 45° instead of
horizontally.
BECOME CLEANER, BETTER
AND MORE PRODUCTIVE –
WITH RITTAL HYGIENIC DESIGN
When it comes to the increasing demands of food safety, stainless
steel enclosures and enclosures in hygienic design are “two different
animals”.
Hygienic Design from Rittal offers mechanical engineers and plant
operators in the food sector and in clean rooms decisive new building
blocks for the hygiene demands of the future. This innovative sub-
range is based on our world-renowned expertise in enclosure
manufacturing and enclosure climate control.
Hygienic Design
Features
6 Rittal Hygienic Design
Rittal Hygienic Design (HD) enclosures are key
elements in the design of open processes in the
food industry and clean rooms with an emphasis
on ease of cleaning.
Also the hygiene conditions of stainless steel cases
and enclosures are decisively optimised with Hygienic
Design system accessories.
Added cleanliness guaranteed!
1
2
3
6
4
5
7
4
1 2 3 4
The roof, which is tilted forwards
by 30°, prevents objects from
being deposited on it, is easily
inspected, and allows fluids to
drain off rapidly.
The large roof projection with the
overhang edge significantly
eases pressure on the seal.
It is easily cleaned, thanks to a
sufficiently large gap between
the overhang edge and the door.
All-round chamfered door edge
folds contribute significantly
towards ease of cleaning.
The durable all-round, external
silicone seal effectively prevents
all gaps. It is easily replaced,
and is clearly distinguishable
from food with its blue colour.
5 6 7
Hinges that are inside the
sealing zone create an
exceptionally easy-clean
design on the outside.
The fastener and lock insert are
made from stainless steel on the
outside. The material, and in
particular the shape, allow easy
and reliable cleaning.
The enclosure surface is fully
sealed. This means that after
machining, only essential
openings remain.
If HD enclosures are used
instead of stainless steel
AE enclosures, there is no
additional project planning work
involved: The mounting plates
have identical dimensions.
Compact enclosures HD, single-door
Hygienic Design
7Rittal Hygienic Design
Material:
Enclosure and door: Stainless
steel
Mounting plate: Sheet steel
Lock inserts HD:
Stainless steel 1.4404
(AISI 316L)
Seal: Conforms to FDA Guide-
line 21 CFR 177.2600
Surface finish:
Enclosure and door:
Brushed, grain 400,
RA< 0.8 μm
Mounting plate: Zinc-plated
Protection category:
IP 66 to EN 60 529
Supply includes:
Enclosure of all-round solid con-
struction, door with press-fitted
seal, interchangeable door
hinge
Detailed drawing,
see page 19.
F
G
T
H2
B
H1
Width (B) mm
Packs
of
220 390 390 510 610 610 810 810 Page
Height
front (H1) mm 350 430 650 550 430 650 1050 1250
rear (H2) mm 437 549 769 669 601 769 1221 1421
Depth (T) mm 155 210 210 210 300 210 300 300
Mounting plate width (F) mm 162 334 334 449 549 549 739 740
Mounting plate height (G) mm 275 355 570 470 355 570 955 1155
Model No. HD 1.4301 (AISI 304) 1 1302.600 1306.600 1308.600 1307.600 1320.600 1310.600 1316.600 1317.600
Model No. HD 1.4404 (AISI 316L) 1 1302.5001) 1306.5001) 1308.5001) 1307.5001) 1320.5001) 1310.5001) 1316.6001) 1317.5001)
Accessories
Wall spacer bracket
50 mm 1 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 9
150 mm1) 1 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 9
300 mm1) 1 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 9
Supporting structure HD with 4 feet, from an enclosure depth of 300 mm depending on design code number, see page 8.
Rails for interior installation, see page 11.
1) Delivery times available on request.
Cable gland HD,
without external thread,
Model No. see page 12.
Levelling feet HD,
without external thread,
Model No. see page 9.
Hygienic Design
Make TS 8 baying systems more hygienic
8 Rittal Hygienic Design
Sloped attachment HD
For TS 8
For retro-fitting individual or bayed TS 8
enclosures of spray-finished sheet steel or
stainless steel.
Properties:
● Height, front: 35 mm.
● Roof projection, front: 8 mm.
● Maximum possible opening at the baying point
to the adjacent roof.
Protection category:
IP 55 to EN 60 529,
complies with NEMA 12.
Supply includes:
Assembly parts and all required seals.
Version Packs of Model No. HD
Stainless steel 1.4301
(AISI 304),
brushed, grain size 400
1 4000.039
Stainless steel 1.4404
(AISI 316L),
brushed, grain size 400
1 4000.049
Sheet steel, spray-finished,
RAL 7035
1 4000.059
Delivery times available on request.
Design code number
– – –
Roof tilt
1 – 30°
(EHEDG standard)
2 – 45°
Enclosure width mm1) Enclosure depth
mm
Assembly (viewed from the front)
1 – for free-standing enlosure
2 – for bayed end enclosure, left2)
3 – for bayed end enclosure, right2)
4 – for bayed enclosure, centre2)
1) Max. 1200 mm
2) Each with a T-section seal and connection accessories.
Example:
Sloped attachment HD, 30° roof tilt, for TS 8 free-standing enclosure with width x depth 800 x 600 mm.
– – –1 800 600 1
Design code number
– – – –
For enclosure
1 – Compact enclosure
HD
2 – TS 8 (stainless steel/
sheet steel)
Enclosure width
mm
Enclosure depth
mm
Levelling
(0 – 55 mm)
1 – with
(for all 4 feet)
2 – without
Base mount
1 – with
2 – without
Supporting structure HD
with levelling
with 4 feet for TS 8
Benefits in detail:
Solid cross-sections and continuously welded
seams ensure complete water-tightness. The
round profile helps to avoid the common problem
of collecting dirt, particularly with horizontal
surfaces.
The guaranteed floor clearance of the enclosures
facilitates easy wet or dry cleaning.
The width supports the installation of individual
supporting structures underneath bayed TS 8
enclosure systems.
Design:
● including levelling 0 – 55 mm
● without base mount
● with horizontal grille for cable routing between
the support strips, rear
Material:
Stainless steel tube 1.4301 (AISI 304)
Supply includes:
Assembly parts and seals.
Accessories:
Wall spacer bracket for secure mounting,
see page 9.
For TS 8
W x D mm
Height mm Model No. HD
800 x 500 300 4000.310
800 x 600 300 4000.311
1200 x 500 300 4000.312
1200 x 600 300 4000.313
To order in stainless steel 1.4404 (AISI 316L),
please add extension .4XX to the Model No.
Supporting structure HD
according to specifications
with 4 feet, height 300 mm
Material Model No. HD
1.4301 (AISI 304) 4000.3091)
1.4404 (AISI 316L) 4000.4091)
1) Please additionally give the design code. Other heights
available on request. Delivery times available on request.
Example:
Supporting structure for TS 8, width 1000 mm, depth 800 mm, without levelling, with base mount.
2 – 1000 – 800 – 2 – 1
Accessories
Hygienic Design
9Rittal Hygienic Design
Levelling feet HD
Material:
Stainless steel 1.4301 (AISI 304)
Supply includes:
Assembly parts and seals.
Benefits in detail:
The threaded spindle for levelling is completely
concealed by a cover, and permanently sealed,
thereby eliminating the time-consuming work of
cleaning and disinfecting the thread.
Floor angles of up to 10° can be compensated.
For
enclosures
Levelling
range
mm
Base
mount
Packs
of
Model No.
HD
TS 8
(M12)
120 – 175
without 4 4000.200
with 4 4000.210
Compact
enclosures
HD (M12)
120 – 175
without 2 4000.220
with 2 4000.230
To order in stainless steel 1.4404 (AISI 316L)
please add the extension .XX1 to the Model No.
Wall spacer bracket HD
Material:
Stainless steel tube 1.4301 (AISI 304)
Supply includes:
Assembly parts and seals.
Benefits in detail:
Finding a way to permanently and securely seal
the enclosure against the wall remains a problem.
With this in mind, we recommend that you leave
sufficient space to clean behind the enclosure.
Depending on the weight and dimensions, one,
two, three, four or more supports may be fitted for
attachment purposes. They may be mounted on
the sides, rear or underside.
Wall spacer brackets may also be used in
customised designs or with an adaptor plate for
mounting other components such as switches and
sockets, as well as wire-mesh cable trays.
Wall distance
mm
Packs of Model No. HD
50 1 4000.100
150 1 4000.1101)
300 1 4000.1201)
1) Delivery times available on request.
To order in stainless steel 1.4404 (AISI 316L)
please add the extension .XX1 to the Model No.
64
50
Ø
34
M8 x ...
15
M10 x ...
HD 4000.100 (mounting alternatives)
Attachment from
inside
Attachment from
outside
Model No. HD H mm
1302.600/.500 330
Model No. HD H mm
1306.600/.500
410
1320.600/.500
1307.600/.500 525
1308.600/.500
625
1310.600/.500
Model No. HD H mm
1316.600/.500 1010
1317.600/.500 1210
Hygienic Design
Accessories
10 Rittal Hygienic Design
Cam lock HD
Hygienic Design variant for easy, safe cleaning.
Applications:
● Compact enclosures AE stainless steel
(except AE 1017.XXX and AE 1019.XXX).
● May be integrated into customised applica-
tions, e.g. covers of machine panels.
Material:
Stainless steel 1.4404 (AISI 316L)
Accessories:
Enclosure key HD,
see page 10.
Ø 28
17
27
5.5
2015
2.5
6.5
SW27
19
35
18.5
Ø
22.3
Packs of Model No. HD
1 2304.010
Lock insert HD
Version F
Hygienic Design version.
Applications:
● Baying system TS 8
● PC enclosure systems, based on TS 8
● Industrial Workstations, based on TS 8
● Comfort handles for lock inserts
Material:
Stainless steel 1.4404 (AISI 316L)
Accessories:
Enclosure key HD,
see page 10.
Packs of Model No. HD
1 8611.400
Enclosure key HD Packs of Model No. HD
1 2549.600
Bit HD
for universal key SZ 2549.500
See Cat. 32, page 959.
Packs of Model No. HD
1 2549.510
Hygienic Design
Accessories
12 Rittal Hygienic Design
Stainless steel cable gland,
Hygienic Design
Suitable for use in the following areas
● Manufacturing and packaging of foodstuffs etc.
● Clean room technology (e.g. pharmaceuticals)
● Biotechnology
● Chemical industry
Benefits:
● Smooth, solid exterior surfaces effectively pre-
vent the depositing of harmful micro-organ-
isms. All threads are beneath the cap nut.
● Much easier, therefore cheaper, cleaning com-
pared with conventional stainless steel cable
glands.
● Reliable strain relief, thanks to duplicate cable
attachment.
● Resistant to high-pressure cleaning (protection
category IP 69K).
Material:
Cap nut: Stainless steel 1.4305 (AISI 303)
Seals: Conforms to FDA Guideline
21 CFR 177.2600
Protection category:
IP 68 (5 bar, 30 min.) to EN 60 529
IP 69K to DIN 40 050-9
Standard version
EMC version
1
2
3
5
6
7
4
Critical points
with conventional
solutions
Cable entry in front
of seal
No minimum radii
on the hexagon
External thread
Gap caused by
O-ring on the
enclosure surface
1
2
3
4
Hygiene-compatible
design features
Seal directly at the
cable entry
Compliance with
minimum radii on
the hexagon
No external thread
Flush termination
between the cap nut
and the enclosure
1
2
3
4
3
4
2
1
3
4
2
1
Why hygiene-compatible cable glands?
Size
Cable
diameter
mm
Packs of Model No. HD
M12 x 1.5 3 – 6.5 5 2410.000
M16 x 1.5 5 – 10 5 2410.010
M20 x 1.5 6 – 12 5 2410.020
M25 x 1.5 12 – 17 5 2410.030
Size
Cable
diameter
mm
Packs of Model No. HD
M16 x 1.5 5 – 10 5 2410.110
M20 x 1.5 6 – 12 5 2410.120
M25 x 1.5 12 – 17 5 2410.130
Seal
Cap nut
Gripper jaws
Shield spring
(EMC version only)
Clamping ring
Enclosure seal
Base with locator for assembly
tool
1
2
3
4
5
6
7
Stainless steel lock nut
To fit the stainless steel Hygienic Design cable
glands.
Material:
Stainless steel 1.4305 (AISI 303)
Factor Packs of Model No. HD
M12 x 1.5 10 2410.200
M16 x 1.5 10 2410.210
M20 x 1.5 10 2410.220
M25 x 1.5 10 2410.230
Assembly tool
for cable gland, stainless steel
Hygienic Design
For attaching a stainless steel Hygienic Design
cable gland to an internal thread or via locking
nuts. This can be achieved either from the inside
or from the outside using an Allen key.
Supply includes:
1 set =
Adaptor for sizes from M12 – M25.
Packs of Model No. HD
1 set 2410.290
Product outlook
Hygienic Design
13Rittal Hygienic Design
Support arm system CP-L,
stainless steel
In conjunction with the HD compact enclosure
and cable entry from below, this offers the ideal
solution for the human/machine interface.
The larger diameter provides space to insert
several cables and/or larger connectors, and
supports greater weights and offers increased
stability when assembling the operating unit.
The support section, bent from a single piece,
offers ideal hygienic conditions. Furthermore,
there are no attachment components or sharp-
edged steps on support arm components such
as wall/floor mounting, enclosure coupling or
enclosure attachment. All seals are external to
ensure optimum hygiene requirements. For wall
mounting from the outside, we recommend an
additional seal and hex screws.
Due to the possibility of condensation forming in
the support arm system as a result of temperature
fluctuations, when cleaning and disinfecting the
plant we recommend that the support arm should
be attached to the bottom of the enclosure
wherever possible.
Support section
Size:
External diameter: 70 mm
Wall thickness: 2.9 mm
Material:
Stainless steel 1.4301
Surface finish:
Brushed, grain 400, polished
Support arm components
Material:
Stainless steel 1.4305
Supply includes:
Assembly parts and seal to the enclosure
Viewing window HD
To protect sensitive installed equipment – such as
panel PCs – from damage during cleaning. In this
way, plant downtime and expensive repairs are
effectively avoided.
Properties:
● Viewing window frame with a 10° all-round
chamfer so that fluids can drain off reliably
● Hinge optionally at the top, right or left
● Silicone seal on the outside, no gap
● Replaceable seal
● Seal dyed blue to clearly distinguish it from
foodstuffs
● Replaceable viewing panel
Material:
Stainless steel 1.4301
Surface finish:
Surface roughness RA< 0.8 μm
Interface extension HD
For extending the internal enclosure interfaces –
e.g. from industrial PCs – up to the outside of the
enclosure.
Benefits:
● Rapid access for maintenance work
● The protection category of the enclosure is
preserved.
● Captive protective cap
Material:
Stainless steel 1.4305
Premium Line
Resistant to high-pressure cleaning
14 Rittal Hygienic Design
The perfect solution for
● Pressure washer resistance
(protection category IP 69K). The seal lies
between two seals and is optimally com-
pressed by the screw fastening.
● Suitability for clean rooms
Optional screw fastening to comply with high
standards in the food and hygiene sectors:
external with hex screws,
internal with plastic bungs.
● Optimum EMC conditions
The labyrinthe seal achieves a particularly high
level of RF shielding of the enclosure.
Accessories:
Rear panel support, interior CP 6682.000.
Holds the rear panel against the enclosure at a
90° angle when it is flipped down; easily removed
if required.
Material:
Stainless steel 1.4301 (AISI 304)
Surface finish:
Brushed, grain 240
Protection category:
IP 69K to DIN 40 050-9
Cover or rear panel screw-fastened:
optional, included with the supply.
1
Screw head on the outside ...
2
... or plastic bungs on the
outside with concealed screws
1
2
Premium Line KL, IP 69 K
For detailed information,
see Catalogue 32, page 306 and 1221.
Dimensions
mm Model No. KL
Width Height Depth
150 150 80 1024.010
150 150 120 1024.020
300 200 120 1024.030
400 300 120 1024.040
To order in stainless steel 1.4404 (AISI 316L), please add extension .5X0 to the Model No.
Delivery times available on request.
Other sizes available on request.
Resistant to high-pressure cleaning
Premium Line
15Rittal Hygienic Design
Premium Panel, IP 69 K
For detailed information,
see Catalogue 32, page 311 and 1222.
Dimensions
mm
Support
arm
connection
Model No.
CP
Width Height Depth
For installation panel
W x H
Installation depth
Operating
housing
Keyboard
housing
Operating
housing
Operating
housing
Keyboard
housing
Operating
housing
Keyboard
housing
With keyboard housing
530 460 200 120
482.6 mm
(19˝) x
354.8 mm
(8 U)
482.6 mm
(19˝) x
177 mm
(4 U)
115
front 58
rear 63
Top 6680.000
530 460 200 120 115
front 58
rear 63
Bottom 6680.010
530 460 200 220 215
front 58
rear 63
Top 6680.100
530 460 200 220 215
front 58
rear 63
Bottom 6680.110
Without keyboard housing
530 360 – 120 482.6 mm
(19˝) x
310 mm
(7 U)
–
115 – Top, or
bottom by
rotating the
enclosure
6681.000
530 360 – 220 215 – 6681.100
To order in stainless steel 1.4404 (AISI 316L), please add extension XX5X.XXX to the Model No.
Delivery times available on request.
Other sizes available on request
Premium TFT 17˝, IP 69 K
Technical specifications:
Resolution max.:
17˝: 1280 x 1024 pixels,
VGA + SXGA non-interlaced
Colours: 16.2 million
Brightness: 300 cd/m2
Reading angle: 150° horizontal, 130° vertical
Contrast ratio: 500 : 1
MTBF backlight: 50,000 h
Voltage: 12 V DC
On Screen Display (OSD) at rear
VGA input: 15 pin D-Sub
Operating temperature: 0°C to +50°C
Power pack SM 6450.050 and connection cable
SM 6450.060, see Cat. 32, page 1134.
Support arm
connection
W
mm
H
mm
T1
mm
T2
mm
Model No.
SM
Bottom 530 360 120 70 6450.100
Top 530 360 120 70 6450.110
To order version in stainless steel 1.4404 (AISI 316L)
please use Model No. SM 6450.5XX.
Delivery times available on request.
Pressure relief stopper
Especially when enclosures are exposed to
changing climatic conditions (e.g. with outdoor
siting), condensation may form in sealed
enclosures due to pressure differences. The
integral sealing membrane largely prevents such
pressure differences and hence condensation;
additionally, it also prevents the ingress of
moisture from the outside.
Installed in vertical surfaces to protect against
dirt.
Technical specifications:
● Air permeability up to 120 litres/hour with a
pressure difference of 70 mbar
● Protection category IP 66, 68, 69K
● Connection thread M12 x 1.5
● For fitting in wall thicknesses up to 4 mm
Material:
Polyamide
Colour:
Similar to RAL 9005 (black)
Supply includes:
Lock nut
Packs of Model No. SZ
5 2459.500
Compact enclosures AE
16 Rittal Hygienic Design
Stainless steel keyboard
19˝/4 U
based on the piezo system.
With this innovative technology, merely tapping
lightly with your finger is sufficent to initiate switch-
ing. There are no edges, cracks or hollows, as
with conventional keyboards. It is therefore parti-
cularly well-suited for the food industry (compact
enclosures Hygienic Design, see page 7).
Technical specifications:
Dimensions of front panel:
482.6 x 177 x 3.7 mm
Installation depth 25 mm
105 keys
Actuator travel/force: 0 mm/0.7 N
Service life: 10 million switching cycles
Keypad: Abrasion-resistant electrolyte lettering
Operating temperature: –25°C to +55°C
PS/2 and USB connection
German layout
Material:
Stainless steel 1.4301
Protection category:
IP 69K to DIN 40 050-9
Supply includes:
Connection cable, length 1.8 m,
with PS/2 connector and hex nuts.
Rittal service:
Country-specific layout available on request.
464.6
482.6 (19˝)
5
159
479.6
170
182.3
174
1.5
104
7
1
32 4
177(4U)
>
Model No. SM
Stainless steel keyboard 6446.010
Front panel cut-out
Seal
Holes for fastening bolts
Contact surface
1
2
3
4
Optical mouse IP 68
Input device for all areas where heavy
contamination is unavoidable or where
exceptional standards of hygiene are crucial.
Benefits:
● High-quality silicone surface.
● Integral optical scanning.
● Sealed on all sides.
● Mechanical operating parts completely
impervious to dirt.
● Easy to clean.
● Also suitable for use in hygiene-sensitive areas.
Technical specifications:
● Optical scanning (with 800 dpi resolution)
● Silicone enclosure with high-quality surface
coating
● Disinfectable
● Application area: from –40°C to +90°C
Protection category:
IP 68 to EN 60 529
Material:
Silicone top
Colour:
Similar to RAL 9002
Supply includes:
USB connection cable,
cable length 1800 mm.
Note:
Not suitable for use in the meat processing
industry.
Accessories:
Connector gland (SZ 2400.500),
see Cat. 32 page 1057.
Support for mousepad (SM 2381.000),
see Cat. 32, page 1145.
Connection Packs of Model No. SM
USB 1 6445.100
PS2 – on request
A partner for your plant
Liquid cooling concepts
17Rittal Hygienic Design
When a cooling water system is installed in the production
plant or hall, the cheapest and most hygienic method of
enclosure climate control is to use air/water heat
exchangers.
Assuming there is no cooling water system available, the
required cooling output for the individual heat exchangers,
either decentralised or centralised, can be provided via
recooling systems, which may be installed outside of the
open process.
In certain cases, e.g. for frequency converters, water cooling
may also be provided inside the enclosure. To this end, drive
modules from a wide range of manufacturers with a cold
plate at the rear may be mounted directly on the DCP water-
cooled mounting plate.
If the potential heat loss of the cold plate is not used com-
pletely for converters, the enclosure internal temperature
may be reduced with the add-on or stand-alone
DCP cooling unit.
Operating housings may be water-cooled using DCP panel
cooling.
The complete solution of enclosure or operating housing
plus cooling concept is supplied by Rittal and ensures a
clean, functional solution for the food industry and related
sectors.
Air/water heat exchangers
Design:
Fully wired ready for connection, plastic mounting
trough, sheet steel cover spray-finished in
RAL 7035, also available in stainless steel 1.4301
(AISI 304) on request.
Protection category:
IP 55, on request IP 65
For detailed information,
see Cat. 32, from page 675.
Recooling systems
Fully wired and plumbed ready for connection,
sheet steel enclosure, spray finished in RAL 7035,
also available in stainless steel 1.4301 (AISI 304)
on request.
For detailed information,
see Cat. 32, from page 654.
Liquid cooling concepts
A partner for your plant
18 Rittal Hygienic Design
DCP mounting plate
Power electronic components can be cooled particularly
effectively using the liquid cooled plate. Heat losses are
cleverly dissipated from the enclosure or housing without
compromising the high enclosure protection category in any
way. Furthermore, liquid cooling is both quiet and a thousand
times more efficient than heat dissipation via air.
The Rittal DCP Cold Plate has received type-
tested certification from the TÜV inspection
authority and is approved for pressures up to
10 bar.
ype Teste
3 basic variants are available for the configuration
of various power electronic components:
Siemens SINAMICS S 120 series Danfoss frequency converter VLT௡
Automation Drive FC300
1. With drilling surface for the
customer to drill their own
tapped holes (core hole
max. 12 mm)
2. With variable wire clamp
system as an accessory for
clamping surface:
● All-round
● Side
● Top and bottom
3. Manufacturer-specific
Other sizes and manufacturers available on request.
For detailed information,
see Cat. 32, from page 731.
Rittal
DCP CoolingUnit
The CoolingUnit is available in
two variants. As a stand-alone
unit with press-fitted cooler
tubes, or as an add-on in
conjunction with a Rittal Cold
Plate. The optional housing for
the cooler ensures even more
efficient air routing and thus
reliable cooling of the air inside
the enclosure.
Detailed information
and accessories,
see Cat. 32, from page 735 and
also at www.rittal.com/dcp
DCP CoolingUnit – Add-on
DCP CoolingUnit – Stand-alone
Rittal
DCP PanelCooling
This integrated PanelCooling
solution was developed by
Rittal for optimum, space-saving
cooling of operating housings.
Heat losses of approx. 150 –
350 W can be dissipated without
the need for external add-ons.
The high protection category of
the enclosure is retained, thanks
to the fluid connection at the
rear of the panel.
Detailed information
and accessories,
see Cat. 32, from page 733 and
also at www.rittal.com/dcp
Technical details
Hygienic Design
19Rittal Hygienic Design
B1
i.L. B2
78H4
200
B3
70 80
3535
158
(10)(10)
(10)
B4
2
3
1
3
2
3
3
4
H2
H1
T2
T1
T3
i.L.H3
50
400
H6
Z
5
5
B1
i.L. B2
368
575
H4
200
H5
90
3535
(10) (10)
60
(10)
B4
7
4
6
7
7
6
7
T2
T1
i.L.H3
H1
H2
T3
50
H5
175
H6
Z
H6
Z
9090
740
12.5
1155
18
700
01
02
03
04
07
08
09
10
11
01
02
03
04
07
08
09
10
11
05
06
05
06
1125
Ø
10
90 90
700
739
930
955
12
01
02
03
04
05
06
07
08
09
01
02
03
04
05
06
07
08
09
Ø
10
F2
F1
90 90
G2
G1
01
02
01
02
03 03
Ø
10
122
138
162
9
122
225
260
275
02
0101
02
Ø
9
Ø
6.5
Compact enclosures HD, single-door
Page 7
Model No. HD Width dimensions mm Height dimensions mm Depth dimensions mm Mounting plates mm Material thickness mm
Stainless
steel
B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 T1 T2 T3 F1 F2 G1 G2 Enclosure Door
Mounting
plate
1302.X00 220 170 – 200 350 437 260 – – 293 155 162 113 – 130 – – – – 1.25 1.5 2.0
1306.X00 390 340 – 370 430 549 340 240 – 373 210 217 168 – 185 334 295 355 330 1.5 1.5 2.0
1307.X00 510 460 375 490 550 669 460 360 – 493 210 217 168 – 185 449 410 470 445 1.5 1.5 2.5
1308.X00 390 340 275 370 650 769 560 460 – 593 210 217 168 – 185 334 295 570 545 1.5 1.5 2.5
1310.X00 610 560 475 590 650 769 560 460 – 593 210 217 168 – 185 549 510 570 545 1.5 2.0 2.5
1316.X00 810 760 – 790 1050 1221 960 280 800 993 300 307 258 – 275 – – – – 1.5 2.0 3.0
1317.X00 810 760 – 790 1250 1421 1160 480 1000 1193 300 307 258 – 275 – – – – 1.5 2.0 3.0
1320.X00 610 560 – 590 430 601 340 240 – 373 300 307 258 – 275 549 510 355 330 1.5 1.5 2.5
H1 =
H2 =
H3 =
H4 =
H5 =
H6 =
Enclosure height, front
Enclosure height, rear
Clearance height of enclosure
Spacing between fasteners
Separation height of threaded bolts
on the door
Height of door
T1 =
T2 =
T3 =
Depth between rear panel and door
Overall depth
Possible mounting depth
(mounting plate assembly)
For HD 1302.X00
For HD 1306.X00, HD 1307.X00,
HD 1308.X00, HD 1310.X00,
HD 1320.X00
For HD 1307.X00, HD 1308.X00,
HD 1310.X00
1
2
3
Max. installation area,
door
For HD 1308.X00,
HD 1310.X00
4
5
For HD 1316.X00
For HD 1317.X00
6
7
HD 1317.X00 HD 1316.X00 HD 1306.X00, HD 1307.X00,
HD 1308.X00, HD 1310.X00,
HD 1320.X00
HD 1302.X00
Mounting plate
F1 =
F2 =
G1 =
G2 =
Mounting plate width
Separation width of attachment bolts
Mounting plate height
Separation height of attachment bolts
Enclosure
B1 =
B2 =
B3 =
B4 =
Overall width
Clearance width of enclosure
Separation width of threaded bolts
on the door
Width of door
HD 1302.X00, HD 1306.X00, HD 1307.X00,
HD 1308.X00, HD 1310.X00, HD 1320.X00
HD 1316.X00, HD 1317.X00
R
Switch to perfection
Small enclosures ⅐ Compact enclosures ⅐ Large enclosures
Products for the human/machine interface ⅐ Console systems
Material: sheet steel, stainless steel, aluminium and plastic
Industrial network technology ⅐ Input and signalling devices
Solutions for EMC and Ex ⅐ Cable glands
All in all – solutions from Rittal
Rittal has one of the largest ranges of enclosures available
for immediate delivery. However, Rittal also supplies inte-
grated solutions – up to Level 4. This comprises mechanical
installation, power supply, electronic components, climate
control and central monitoring. For all of your requirements.
Fully assembled and functional. Wherever in the world you
develop and implement solutions for yourself and your
customers, we are close at hand. The global alliance
between production, distribution and service guarantees
closeness to the customer. Worldwide!
01/09⅐E973
Electronic Packaging
IT Solutions
Communication Systems
System Climate Control
Power Distribution
Industrial Enclosures
Rittal GmbH & Co. KG ⅐ Postfach 1662 ⅐ D-35726 Herborn
Telephone: +49(0)2772 505-0 ⅐ Telefax: +49(0)2772 505-2319 ⅐ eMail: info@rittal.de ⅐ www.rittal.com
Rittal –
Terminal boxes HD
Hygienic Design
Terminal boxes HD
Rittal terminal boxes in Hygienic Design (HD) have
been tailored for optimum incorporation into machinery
and equipment for use in open processes in the food
industry and are thus a perfect complement to the
proven compact enclosures HD.
Extra cleanliness guaranteed!
Rittal Limited,Braithwell Way, Hellaby Ind Estate, Hellaby, Rotherham, S. Yorkshire, S66 8QY
Telephone: 01709 704000 Fax: 01709 701217 E-mail: information@rittal.co.uk Web: www.rittal.co.uk
Benefits:
Simple cleaning
● Inclined surfaces: 3° on all
sides, 10° on the cover
● All-round gap-free
silicone seal between
enclosure and cover
● Hygiene-compliant
hexagon locks
Easy assembly
● Quick-release cover locks
● Simple replacement of the
silicone seal
Component installation
● Hole pitch of 6.25 mm
for greater flexibility
● KL support rails and
mounting plates can
be fitted directly
04/2010
Width
front mm Packs of 150 150 200 300 400
rear mm 172 177 227 327 427
Height
front mm 150 150 200 200 200
rear mm 172 177 227 227 227
Depth mm 80 120 120 120 120
Model No. HD 1 1670.600 1671.600 1672.600 1674.600 1675.600
Accessories
Wall spacer 50 mm 1 4000.100 4000.100 4000.100 4000.100 4000.100
Mounting plate 1 1560.700 1560.700 1562.700 1563.700 1564.700
Support rail TS 35/7.5 10 2314.000 2314.000 2315.000 2316.000 2317.000
Material:
Enclosure and cover:
Stainless steel 1.4301 (AISI 304)
1.5 mm
Mounting bracket:
Sheet steel, zinc-plated, 2.0 mm
Quick-release locks:
Stainless steel 1.4301 (AISI 304)
Seal: Silicone, compliant with
FDA 21 CFR 177.2600
Surface finish:
Enclosure and cover:
Brushed finish, grain 400,
RA < 0.8 μm
Seal: Blue, dyed (RAL 5010)
Protection category:
IP 66 to EN 60 529
Scope of delivery:
Enclosure with unbroken sur-
face, cover, mounting bracket
(pre-assembled), seal and
quick-release locks (enclosed).
Accessories:
Cable glands HD, see
Rittal catalogue 32, page 1056.
Detail drawing
can be found on the Internet.
R
hmi_hd.fm Seite 2 Freitag, 10. Juli 2009 12:47 12
Command Panel HD –
Extra cleanliness guaranteed
Command Panel HD
with pedestal
Switch to perfection
07/09
Rittal Limited ⅐ Braithwell Way ⅐ Hellaby Industrial Estate ⅐ Hellaby ⅐ Rotherham ⅐ S Yorks S66 8QY
Tel.: (01709) 704000 ⅐ Fax: (01709) 701217 ⅐ www.rittal.co.uk ⅐ eMail: information@rittal.co.uk
Basic enclosure:
● W x H x D:
610 x 650/823.3 x 300 mm
● Integrated viewing window,
flush-mounted with silicone
seals, W x H: 380 x 313 mm
● PC shelf with nylon loop to
secure the PC
● Inner door with VESA mount
for TFT monitor,
W x H: 400 x 360 mm
● Enclosure with unbroken
surfaces (preparation for
cable entry upon request)
Keyboard housing:
● W x H x D:
608 x 45/62 x 200 mm
● Connection to the basic
enclosure via tubes,
length 60 mm
● Stainless steel keyboard
19˝/4 U, piezo technology,
UK keyboard layout (other
country variants upon
request), USB connecting
cable
● Modular optical trackball unit,
51 mm dia, with 3 buttons
and USB connecting cable
Pedestal:
● Comprising a base plate,
two tubular legs Ø 70 mm
and two enclosure mounts,
with fully welded joints
between all parts
● Height: 996 mm
● Base plate
W x D: 600 x 400 mm with
floor fixing holes
Complete solution for use
in the food and drinks
industry.
Prepared for installation
of a standard PC up to
160 x 500 x 500 mm and
a TFT monitor up to max.
17˝ with VESA mount.
Where foods are handled in a continuous process, it is often
necessary to provide control and monitoring of production.
Such areas are particularly critical with regard to hygiene, as
the presence of an operator can easily lead to cross-contam-
ination, and thus special hygienic solutions are imperative.
Rittal’s pedestal-mounted command panel is ideally suited to
this task. A further benefit: The modularity of the PC hard-
ware guarantees the cost-effective replacement of individual
components should this become necessary.
Also required:
Socket strip, see Catalogue 32, pages 1038 to 1043.
Stainless steel cable gland, Hygienic Design,
see Catalogue 32, page 1056.
Possible
alternative:
As an alternative to the pedestal, wall mounting is possible,
e.g. by way of a 50 mm wall spacer bracket HD 4000.100
(see Catalogue 32, page 301).
Model No.
Basic enclosure with keyboard housing 4000.009-BM NuG 100
Pedestal 4000.029-BM NuG 500
hmi_hd.fm Seite 1 Freitag, 10. Juli 2009 12:47 12
WWW.CABLEJOINTS.CO.UK
THORNE & DERRICK UK
TEL 0044 191 490 1547 FAX 0044 477 5371
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK

More Related Content

Similar to Rittal Stainless Steel Electrical Enclosures for the Food & Beverage Industry

Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavengerTwin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Roy Niekerk
 
Ultrawave IND-Series Ultrasonic Cleaners
Ultrawave IND-Series Ultrasonic CleanersUltrawave IND-Series Ultrasonic Cleaners
Ultrawave IND-Series Ultrasonic Cleaners
Damon Beach
 
Jabsco Hygienic Product Range
Jabsco Hygienic Product RangeJabsco Hygienic Product Range
Jabsco Hygienic Product Range
ERIKS UK
 
Askon_full_catalog_17-10-23_compressed.pdf
Askon_full_catalog_17-10-23_compressed.pdfAskon_full_catalog_17-10-23_compressed.pdf
Askon_full_catalog_17-10-23_compressed.pdf
marketing323114
 
Biotec Dental Implants Kits & Tools Catalogue 2019
Biotec Dental Implants Kits & Tools Catalogue 2019Biotec Dental Implants Kits & Tools Catalogue 2019
Biotec Dental Implants Kits & Tools Catalogue 2019
HikmatNajjar
 
Innovations 2015
Innovations 2015Innovations 2015
Innovations 2015
Eeu SC
 
Innovations 2015
Innovations  2015Innovations  2015
Innovations 2015
Eeu SC
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Tony Rhodes
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Simon Bailey
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
Kathryn Jepson
 
ACO GULLY 218 – Bodies for 300mm grates
ACO GULLY 218 – Bodies for 300mm gratesACO GULLY 218 – Bodies for 300mm grates
ACO GULLY 218 – Bodies for 300mm grates
Acogully
 
Cinchseals replacing packing
Cinchseals replacing packingCinchseals replacing packing
Cinchseals replacing packing
Mainliner Freightways LTD
 
brochure 2020 - Zeno Protect Entrance Flooring
brochure 2020 - Zeno Protect Entrance Flooringbrochure 2020 - Zeno Protect Entrance Flooring
brochure 2020 - Zeno Protect Entrance Flooring
Zeno-Protect B.V.
 
Brochure Zeno Protect Entrance Flooring
Brochure Zeno Protect Entrance FlooringBrochure Zeno Protect Entrance Flooring
Brochure Zeno Protect Entrance Flooring
Zeno-Protect B.V.
 
Ultrawave industrial ultrasonic cleaners brochure
Ultrawave industrial ultrasonic cleaners brochureUltrawave industrial ultrasonic cleaners brochure
Ultrawave industrial ultrasonic cleaners brochure
Ultrawave Ltd
 
Tarkett suelo pvc I q granit
Tarkett suelo pvc I q granitTarkett suelo pvc I q granit
Tarkett suelo pvc I q granit
Pavireli
 
Acoustic Enclosure
Acoustic EnclosureAcoustic Enclosure
Acoustic Enclosure
Ecotone Systems Pvt Ltd
 
Acoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt LtdAcoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt Ltd
Ecotone Systems Pvt Ltd
 
2015 Hi Clean Catalog
2015 Hi Clean Catalog2015 Hi Clean Catalog
2015 Hi Clean Catalog
Waldo Sanchez
 
Esco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and Double
Esco Group
 

Similar to Rittal Stainless Steel Electrical Enclosures for the Food & Beverage Industry (20)

Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavengerTwin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
Twin Process Filtration - Brochure Horizontal Plate Filter (HPF) with scavenger
 
Ultrawave IND-Series Ultrasonic Cleaners
Ultrawave IND-Series Ultrasonic CleanersUltrawave IND-Series Ultrasonic Cleaners
Ultrawave IND-Series Ultrasonic Cleaners
 
Jabsco Hygienic Product Range
Jabsco Hygienic Product RangeJabsco Hygienic Product Range
Jabsco Hygienic Product Range
 
Askon_full_catalog_17-10-23_compressed.pdf
Askon_full_catalog_17-10-23_compressed.pdfAskon_full_catalog_17-10-23_compressed.pdf
Askon_full_catalog_17-10-23_compressed.pdf
 
Biotec Dental Implants Kits & Tools Catalogue 2019
Biotec Dental Implants Kits & Tools Catalogue 2019Biotec Dental Implants Kits & Tools Catalogue 2019
Biotec Dental Implants Kits & Tools Catalogue 2019
 
Innovations 2015
Innovations 2015Innovations 2015
Innovations 2015
 
Innovations 2015
Innovations  2015Innovations  2015
Innovations 2015
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
Telstar Pura STI Brochure
Telstar Pura STI BrochureTelstar Pura STI Brochure
Telstar Pura STI Brochure
 
ACO GULLY 218 – Bodies for 300mm grates
ACO GULLY 218 – Bodies for 300mm gratesACO GULLY 218 – Bodies for 300mm grates
ACO GULLY 218 – Bodies for 300mm grates
 
Cinchseals replacing packing
Cinchseals replacing packingCinchseals replacing packing
Cinchseals replacing packing
 
brochure 2020 - Zeno Protect Entrance Flooring
brochure 2020 - Zeno Protect Entrance Flooringbrochure 2020 - Zeno Protect Entrance Flooring
brochure 2020 - Zeno Protect Entrance Flooring
 
Brochure Zeno Protect Entrance Flooring
Brochure Zeno Protect Entrance FlooringBrochure Zeno Protect Entrance Flooring
Brochure Zeno Protect Entrance Flooring
 
Ultrawave industrial ultrasonic cleaners brochure
Ultrawave industrial ultrasonic cleaners brochureUltrawave industrial ultrasonic cleaners brochure
Ultrawave industrial ultrasonic cleaners brochure
 
Tarkett suelo pvc I q granit
Tarkett suelo pvc I q granitTarkett suelo pvc I q granit
Tarkett suelo pvc I q granit
 
Acoustic Enclosure
Acoustic EnclosureAcoustic Enclosure
Acoustic Enclosure
 
Acoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt LtdAcoustic Enclosure - Ecotone Systems Pvt Ltd
Acoustic Enclosure - Ecotone Systems Pvt Ltd
 
2015 Hi Clean Catalog
2015 Hi Clean Catalog2015 Hi Clean Catalog
2015 Hi Clean Catalog
 
Esco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and DoubleEsco Pharma Laminar Flow Straddle Units, Single and Double
Esco Pharma Laminar Flow Straddle Units, Single and Double
 

More from Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
Thorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
Thorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
Thorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Thorne & Derrick International
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Thorne & Derrick International
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
Thorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
Thorne & Derrick International
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
Thorne & Derrick International
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
Thorne & Derrick International
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
Thorne & Derrick International
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
Thorne & Derrick International
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Thorne & Derrick International
 

More from Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Recently uploaded

“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
Edge AI and Vision Alliance
 
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
Neo4j
 
RESUME BUILDER APPLICATION Project for students
RESUME BUILDER APPLICATION Project for studentsRESUME BUILDER APPLICATION Project for students
RESUME BUILDER APPLICATION Project for students
KAMESHS29
 
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
SOFTTECHHUB
 
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
Neo4j
 
Introduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - CybersecurityIntroduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - Cybersecurity
mikeeftimakis1
 
Monitoring Java Application Security with JDK Tools and JFR Events
Monitoring Java Application Security with JDK Tools and JFR EventsMonitoring Java Application Security with JDK Tools and JFR Events
Monitoring Java Application Security with JDK Tools and JFR Events
Ana-Maria Mihalceanu
 
Microsoft - Power Platform_G.Aspiotis.pdf
Microsoft - Power Platform_G.Aspiotis.pdfMicrosoft - Power Platform_G.Aspiotis.pdf
Microsoft - Power Platform_G.Aspiotis.pdf
Uni Systems S.M.S.A.
 
UiPath Test Automation using UiPath Test Suite series, part 5
UiPath Test Automation using UiPath Test Suite series, part 5UiPath Test Automation using UiPath Test Suite series, part 5
UiPath Test Automation using UiPath Test Suite series, part 5
DianaGray10
 
UiPath Test Automation using UiPath Test Suite series, part 6
UiPath Test Automation using UiPath Test Suite series, part 6UiPath Test Automation using UiPath Test Suite series, part 6
UiPath Test Automation using UiPath Test Suite series, part 6
DianaGray10
 
Generative AI Deep Dive: Advancing from Proof of Concept to Production
Generative AI Deep Dive: Advancing from Proof of Concept to ProductionGenerative AI Deep Dive: Advancing from Proof of Concept to Production
Generative AI Deep Dive: Advancing from Proof of Concept to Production
Aggregage
 
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
Zilliz
 
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with SlackLet's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
shyamraj55
 
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
Neo4j
 
20240607 QFM018 Elixir Reading List May 2024
20240607 QFM018 Elixir Reading List May 202420240607 QFM018 Elixir Reading List May 2024
20240607 QFM018 Elixir Reading List May 2024
Matthew Sinclair
 
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
James Anderson
 
Data structures and Algorithms in Python.pdf
Data structures and Algorithms in Python.pdfData structures and Algorithms in Python.pdf
Data structures and Algorithms in Python.pdf
TIPNGVN2
 
TrustArc Webinar - 2024 Global Privacy Survey
TrustArc Webinar - 2024 Global Privacy SurveyTrustArc Webinar - 2024 Global Privacy Survey
TrustArc Webinar - 2024 Global Privacy Survey
TrustArc
 
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
名前 です男
 
Full-RAG: A modern architecture for hyper-personalization
Full-RAG: A modern architecture for hyper-personalizationFull-RAG: A modern architecture for hyper-personalization
Full-RAG: A modern architecture for hyper-personalization
Zilliz
 

Recently uploaded (20)

“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
“Building and Scaling AI Applications with the Nx AI Manager,” a Presentation...
 
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
GraphSummit Singapore | Graphing Success: Revolutionising Organisational Stru...
 
RESUME BUILDER APPLICATION Project for students
RESUME BUILDER APPLICATION Project for studentsRESUME BUILDER APPLICATION Project for students
RESUME BUILDER APPLICATION Project for students
 
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!
 
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...
 
Introduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - CybersecurityIntroduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - Cybersecurity
 
Monitoring Java Application Security with JDK Tools and JFR Events
Monitoring Java Application Security with JDK Tools and JFR EventsMonitoring Java Application Security with JDK Tools and JFR Events
Monitoring Java Application Security with JDK Tools and JFR Events
 
Microsoft - Power Platform_G.Aspiotis.pdf
Microsoft - Power Platform_G.Aspiotis.pdfMicrosoft - Power Platform_G.Aspiotis.pdf
Microsoft - Power Platform_G.Aspiotis.pdf
 
UiPath Test Automation using UiPath Test Suite series, part 5
UiPath Test Automation using UiPath Test Suite series, part 5UiPath Test Automation using UiPath Test Suite series, part 5
UiPath Test Automation using UiPath Test Suite series, part 5
 
UiPath Test Automation using UiPath Test Suite series, part 6
UiPath Test Automation using UiPath Test Suite series, part 6UiPath Test Automation using UiPath Test Suite series, part 6
UiPath Test Automation using UiPath Test Suite series, part 6
 
Generative AI Deep Dive: Advancing from Proof of Concept to Production
Generative AI Deep Dive: Advancing from Proof of Concept to ProductionGenerative AI Deep Dive: Advancing from Proof of Concept to Production
Generative AI Deep Dive: Advancing from Proof of Concept to Production
 
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
Introducing Milvus Lite: Easy-to-Install, Easy-to-Use vector database for you...
 
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with SlackLet's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slack
 
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
GraphSummit Singapore | Enhancing Changi Airport Group's Passenger Experience...
 
20240607 QFM018 Elixir Reading List May 2024
20240607 QFM018 Elixir Reading List May 202420240607 QFM018 Elixir Reading List May 2024
20240607 QFM018 Elixir Reading List May 2024
 
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
Alt. GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using ...
 
Data structures and Algorithms in Python.pdf
Data structures and Algorithms in Python.pdfData structures and Algorithms in Python.pdf
Data structures and Algorithms in Python.pdf
 
TrustArc Webinar - 2024 Global Privacy Survey
TrustArc Webinar - 2024 Global Privacy SurveyTrustArc Webinar - 2024 Global Privacy Survey
TrustArc Webinar - 2024 Global Privacy Survey
 
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
みなさんこんにちはこれ何文字まで入るの?40文字以下不可とか本当に意味わからないけどこれ限界文字数書いてないからマジでやばい文字数いけるんじゃないの?えこ...
 
Full-RAG: A modern architecture for hyper-personalization
Full-RAG: A modern architecture for hyper-personalizationFull-RAG: A modern architecture for hyper-personalization
Full-RAG: A modern architecture for hyper-personalization
 

Rittal Stainless Steel Electrical Enclosures for the Food & Beverage Industry

  • 1. R Extra cleanliness guaranteed Rittal – Hygienic Design WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 477 5371 TEL 0044 117 977 4647 FAX 0044 977 5582 WWW.THORNEANDDERRICK.CO.UK
  • 2. 2 Rittal Hygienic Design The Rittal Hygienic Design for food safety is based on: ● Machinery Directive (Directive 98/37/EC) Food Machinery section, Appendix 1, point 2.1 (to be replaced by 2006/42/EC) ● DIN EN 1672-2:2005 Food machinery – General design princi- ples – Part 2: Hygiene requirements ● DIN EN ISO 14 159 Machine safety – Hygiene requirements pertaining to the design of machinery ● Document 13 EHEDG- Guideline to the hygienic design of apparatus for open processes, prepared in collaboration with 3-A and NSF International Become cleaner better and more productive – with Rittal Hygienic Design. Benefits compared with conventional enclosures: ● Higher productivity through greater system availability. ● Reducing the amount of cleaning required (faster cleaning, reduced energy requirements, reduced use of chemicals). ● Superior product quality and greater durability by reducing the contamination risk, which in turn helps to avoid production losses. ● Improved protection for both consumers and employees. HDRittal Hygienic Design
  • 3. 3Rittal Hygienic Design Cleaning and disinfection Hygiene checks and the monitoring of cleaning processes have revealed that the use of high pressure washing harbours the risk of organic contaminants (fats or proteins) entering niches and being more widely distributed. For this reason, pressures are being significantly reduced. Decide for yourself what is important: ● High pressure-resistant design A labyrinth in front of the seal or multiple screw-fastening of the lid or door to the enclo- sure, to enable the use of high pressure hosing of up to 120 bar, whether static or manual. As well as hampering servic- ing, multiple screw-fastening also harbours additional hygiene risks resulting from incorrectly tightened screws or damaged seals. ● Hygienic design The new Hygienic Design avoids the hollows and dead spaces found in labyrinths for high pressure applications. RITTAL OFFERS THE “KEY” TO OPTIMUM HYGIENE FOR ALL SECTORS! The completely new lock insert is synonymous with the consistency of Hygienic Design from Rittal. Featuring a high protection category, it has nowhere for micro-organisms to hide, making cleaning easy. The same is true of the entire new product line, in every respect. Rittal Hygienic Design reduces the risk of contamination and significantly increases your productivity. Meat, poultry, fish, delicatessen products, ready meals Beverages, fruit and vegetables Milk processing, cheese and dairy product manufacturing Baked goods and confectionery
  • 4. 4 Rittal Hygienic Design Make existing plant more hygienic. This saves time with cleaning and disinfection, i.e. down- time is reduced, or plant productivity is increased, provided ... Optimise existing machines and systems The growing incidence of food poisoning and food product recalls caused by microbial, physical or chemical contami- nation underscore the need for reliable hygiene standards. ... the wall-mounted devices and enclosures are installed at a distance for cleaning purposes. With the HD wall spacer bracket. … enclosures with cable entry from below are mounted on the new HD supporting structure rather than on a base/plinth or a mounting angle frame.
  • 5. 5Rittal Hygienic Design ... the new HD levelling feet eliminate the need for adjustment with external threads. ... the polyamide or brass cable entry with external thread is replaced by the new HD stainless steel cable gland. ... the standard flat roofs in TS 8 enclosures are replaced by a sloped attachment. ... terminal boxes (Premium- KL IP 69K), used e.g. as socket outlets, are mounted on the wall at 45° instead of horizontally. BECOME CLEANER, BETTER AND MORE PRODUCTIVE – WITH RITTAL HYGIENIC DESIGN When it comes to the increasing demands of food safety, stainless steel enclosures and enclosures in hygienic design are “two different animals”. Hygienic Design from Rittal offers mechanical engineers and plant operators in the food sector and in clean rooms decisive new building blocks for the hygiene demands of the future. This innovative sub- range is based on our world-renowned expertise in enclosure manufacturing and enclosure climate control.
  • 6. Hygienic Design Features 6 Rittal Hygienic Design Rittal Hygienic Design (HD) enclosures are key elements in the design of open processes in the food industry and clean rooms with an emphasis on ease of cleaning. Also the hygiene conditions of stainless steel cases and enclosures are decisively optimised with Hygienic Design system accessories. Added cleanliness guaranteed! 1 2 3 6 4 5 7 4 1 2 3 4 The roof, which is tilted forwards by 30°, prevents objects from being deposited on it, is easily inspected, and allows fluids to drain off rapidly. The large roof projection with the overhang edge significantly eases pressure on the seal. It is easily cleaned, thanks to a sufficiently large gap between the overhang edge and the door. All-round chamfered door edge folds contribute significantly towards ease of cleaning. The durable all-round, external silicone seal effectively prevents all gaps. It is easily replaced, and is clearly distinguishable from food with its blue colour. 5 6 7 Hinges that are inside the sealing zone create an exceptionally easy-clean design on the outside. The fastener and lock insert are made from stainless steel on the outside. The material, and in particular the shape, allow easy and reliable cleaning. The enclosure surface is fully sealed. This means that after machining, only essential openings remain. If HD enclosures are used instead of stainless steel AE enclosures, there is no additional project planning work involved: The mounting plates have identical dimensions.
  • 7. Compact enclosures HD, single-door Hygienic Design 7Rittal Hygienic Design Material: Enclosure and door: Stainless steel Mounting plate: Sheet steel Lock inserts HD: Stainless steel 1.4404 (AISI 316L) Seal: Conforms to FDA Guide- line 21 CFR 177.2600 Surface finish: Enclosure and door: Brushed, grain 400, RA< 0.8 μm Mounting plate: Zinc-plated Protection category: IP 66 to EN 60 529 Supply includes: Enclosure of all-round solid con- struction, door with press-fitted seal, interchangeable door hinge Detailed drawing, see page 19. F G T H2 B H1 Width (B) mm Packs of 220 390 390 510 610 610 810 810 Page Height front (H1) mm 350 430 650 550 430 650 1050 1250 rear (H2) mm 437 549 769 669 601 769 1221 1421 Depth (T) mm 155 210 210 210 300 210 300 300 Mounting plate width (F) mm 162 334 334 449 549 549 739 740 Mounting plate height (G) mm 275 355 570 470 355 570 955 1155 Model No. HD 1.4301 (AISI 304) 1 1302.600 1306.600 1308.600 1307.600 1320.600 1310.600 1316.600 1317.600 Model No. HD 1.4404 (AISI 316L) 1 1302.5001) 1306.5001) 1308.5001) 1307.5001) 1320.5001) 1310.5001) 1316.6001) 1317.5001) Accessories Wall spacer bracket 50 mm 1 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 4000.100 9 150 mm1) 1 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 4000.110 9 300 mm1) 1 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 4000.120 9 Supporting structure HD with 4 feet, from an enclosure depth of 300 mm depending on design code number, see page 8. Rails for interior installation, see page 11. 1) Delivery times available on request. Cable gland HD, without external thread, Model No. see page 12. Levelling feet HD, without external thread, Model No. see page 9.
  • 8. Hygienic Design Make TS 8 baying systems more hygienic 8 Rittal Hygienic Design Sloped attachment HD For TS 8 For retro-fitting individual or bayed TS 8 enclosures of spray-finished sheet steel or stainless steel. Properties: ● Height, front: 35 mm. ● Roof projection, front: 8 mm. ● Maximum possible opening at the baying point to the adjacent roof. Protection category: IP 55 to EN 60 529, complies with NEMA 12. Supply includes: Assembly parts and all required seals. Version Packs of Model No. HD Stainless steel 1.4301 (AISI 304), brushed, grain size 400 1 4000.039 Stainless steel 1.4404 (AISI 316L), brushed, grain size 400 1 4000.049 Sheet steel, spray-finished, RAL 7035 1 4000.059 Delivery times available on request. Design code number – – – Roof tilt 1 – 30° (EHEDG standard) 2 – 45° Enclosure width mm1) Enclosure depth mm Assembly (viewed from the front) 1 – for free-standing enlosure 2 – for bayed end enclosure, left2) 3 – for bayed end enclosure, right2) 4 – for bayed enclosure, centre2) 1) Max. 1200 mm 2) Each with a T-section seal and connection accessories. Example: Sloped attachment HD, 30° roof tilt, for TS 8 free-standing enclosure with width x depth 800 x 600 mm. – – –1 800 600 1 Design code number – – – – For enclosure 1 – Compact enclosure HD 2 – TS 8 (stainless steel/ sheet steel) Enclosure width mm Enclosure depth mm Levelling (0 – 55 mm) 1 – with (for all 4 feet) 2 – without Base mount 1 – with 2 – without Supporting structure HD with levelling with 4 feet for TS 8 Benefits in detail: Solid cross-sections and continuously welded seams ensure complete water-tightness. The round profile helps to avoid the common problem of collecting dirt, particularly with horizontal surfaces. The guaranteed floor clearance of the enclosures facilitates easy wet or dry cleaning. The width supports the installation of individual supporting structures underneath bayed TS 8 enclosure systems. Design: ● including levelling 0 – 55 mm ● without base mount ● with horizontal grille for cable routing between the support strips, rear Material: Stainless steel tube 1.4301 (AISI 304) Supply includes: Assembly parts and seals. Accessories: Wall spacer bracket for secure mounting, see page 9. For TS 8 W x D mm Height mm Model No. HD 800 x 500 300 4000.310 800 x 600 300 4000.311 1200 x 500 300 4000.312 1200 x 600 300 4000.313 To order in stainless steel 1.4404 (AISI 316L), please add extension .4XX to the Model No. Supporting structure HD according to specifications with 4 feet, height 300 mm Material Model No. HD 1.4301 (AISI 304) 4000.3091) 1.4404 (AISI 316L) 4000.4091) 1) Please additionally give the design code. Other heights available on request. Delivery times available on request. Example: Supporting structure for TS 8, width 1000 mm, depth 800 mm, without levelling, with base mount. 2 – 1000 – 800 – 2 – 1
  • 9. Accessories Hygienic Design 9Rittal Hygienic Design Levelling feet HD Material: Stainless steel 1.4301 (AISI 304) Supply includes: Assembly parts and seals. Benefits in detail: The threaded spindle for levelling is completely concealed by a cover, and permanently sealed, thereby eliminating the time-consuming work of cleaning and disinfecting the thread. Floor angles of up to 10° can be compensated. For enclosures Levelling range mm Base mount Packs of Model No. HD TS 8 (M12) 120 – 175 without 4 4000.200 with 4 4000.210 Compact enclosures HD (M12) 120 – 175 without 2 4000.220 with 2 4000.230 To order in stainless steel 1.4404 (AISI 316L) please add the extension .XX1 to the Model No. Wall spacer bracket HD Material: Stainless steel tube 1.4301 (AISI 304) Supply includes: Assembly parts and seals. Benefits in detail: Finding a way to permanently and securely seal the enclosure against the wall remains a problem. With this in mind, we recommend that you leave sufficient space to clean behind the enclosure. Depending on the weight and dimensions, one, two, three, four or more supports may be fitted for attachment purposes. They may be mounted on the sides, rear or underside. Wall spacer brackets may also be used in customised designs or with an adaptor plate for mounting other components such as switches and sockets, as well as wire-mesh cable trays. Wall distance mm Packs of Model No. HD 50 1 4000.100 150 1 4000.1101) 300 1 4000.1201) 1) Delivery times available on request. To order in stainless steel 1.4404 (AISI 316L) please add the extension .XX1 to the Model No. 64 50 Ø 34 M8 x ... 15 M10 x ... HD 4000.100 (mounting alternatives) Attachment from inside Attachment from outside Model No. HD H mm 1302.600/.500 330 Model No. HD H mm 1306.600/.500 410 1320.600/.500 1307.600/.500 525 1308.600/.500 625 1310.600/.500 Model No. HD H mm 1316.600/.500 1010 1317.600/.500 1210
  • 10. Hygienic Design Accessories 10 Rittal Hygienic Design Cam lock HD Hygienic Design variant for easy, safe cleaning. Applications: ● Compact enclosures AE stainless steel (except AE 1017.XXX and AE 1019.XXX). ● May be integrated into customised applica- tions, e.g. covers of machine panels. Material: Stainless steel 1.4404 (AISI 316L) Accessories: Enclosure key HD, see page 10. Ø 28 17 27 5.5 2015 2.5 6.5 SW27 19 35 18.5 Ø 22.3 Packs of Model No. HD 1 2304.010 Lock insert HD Version F Hygienic Design version. Applications: ● Baying system TS 8 ● PC enclosure systems, based on TS 8 ● Industrial Workstations, based on TS 8 ● Comfort handles for lock inserts Material: Stainless steel 1.4404 (AISI 316L) Accessories: Enclosure key HD, see page 10. Packs of Model No. HD 1 8611.400 Enclosure key HD Packs of Model No. HD 1 2549.600 Bit HD for universal key SZ 2549.500 See Cat. 32, page 959. Packs of Model No. HD 1 2549.510
  • 11.
  • 12. Hygienic Design Accessories 12 Rittal Hygienic Design Stainless steel cable gland, Hygienic Design Suitable for use in the following areas ● Manufacturing and packaging of foodstuffs etc. ● Clean room technology (e.g. pharmaceuticals) ● Biotechnology ● Chemical industry Benefits: ● Smooth, solid exterior surfaces effectively pre- vent the depositing of harmful micro-organ- isms. All threads are beneath the cap nut. ● Much easier, therefore cheaper, cleaning com- pared with conventional stainless steel cable glands. ● Reliable strain relief, thanks to duplicate cable attachment. ● Resistant to high-pressure cleaning (protection category IP 69K). Material: Cap nut: Stainless steel 1.4305 (AISI 303) Seals: Conforms to FDA Guideline 21 CFR 177.2600 Protection category: IP 68 (5 bar, 30 min.) to EN 60 529 IP 69K to DIN 40 050-9 Standard version EMC version 1 2 3 5 6 7 4 Critical points with conventional solutions Cable entry in front of seal No minimum radii on the hexagon External thread Gap caused by O-ring on the enclosure surface 1 2 3 4 Hygiene-compatible design features Seal directly at the cable entry Compliance with minimum radii on the hexagon No external thread Flush termination between the cap nut and the enclosure 1 2 3 4 3 4 2 1 3 4 2 1 Why hygiene-compatible cable glands? Size Cable diameter mm Packs of Model No. HD M12 x 1.5 3 – 6.5 5 2410.000 M16 x 1.5 5 – 10 5 2410.010 M20 x 1.5 6 – 12 5 2410.020 M25 x 1.5 12 – 17 5 2410.030 Size Cable diameter mm Packs of Model No. HD M16 x 1.5 5 – 10 5 2410.110 M20 x 1.5 6 – 12 5 2410.120 M25 x 1.5 12 – 17 5 2410.130 Seal Cap nut Gripper jaws Shield spring (EMC version only) Clamping ring Enclosure seal Base with locator for assembly tool 1 2 3 4 5 6 7 Stainless steel lock nut To fit the stainless steel Hygienic Design cable glands. Material: Stainless steel 1.4305 (AISI 303) Factor Packs of Model No. HD M12 x 1.5 10 2410.200 M16 x 1.5 10 2410.210 M20 x 1.5 10 2410.220 M25 x 1.5 10 2410.230 Assembly tool for cable gland, stainless steel Hygienic Design For attaching a stainless steel Hygienic Design cable gland to an internal thread or via locking nuts. This can be achieved either from the inside or from the outside using an Allen key. Supply includes: 1 set = Adaptor for sizes from M12 – M25. Packs of Model No. HD 1 set 2410.290
  • 13. Product outlook Hygienic Design 13Rittal Hygienic Design Support arm system CP-L, stainless steel In conjunction with the HD compact enclosure and cable entry from below, this offers the ideal solution for the human/machine interface. The larger diameter provides space to insert several cables and/or larger connectors, and supports greater weights and offers increased stability when assembling the operating unit. The support section, bent from a single piece, offers ideal hygienic conditions. Furthermore, there are no attachment components or sharp- edged steps on support arm components such as wall/floor mounting, enclosure coupling or enclosure attachment. All seals are external to ensure optimum hygiene requirements. For wall mounting from the outside, we recommend an additional seal and hex screws. Due to the possibility of condensation forming in the support arm system as a result of temperature fluctuations, when cleaning and disinfecting the plant we recommend that the support arm should be attached to the bottom of the enclosure wherever possible. Support section Size: External diameter: 70 mm Wall thickness: 2.9 mm Material: Stainless steel 1.4301 Surface finish: Brushed, grain 400, polished Support arm components Material: Stainless steel 1.4305 Supply includes: Assembly parts and seal to the enclosure Viewing window HD To protect sensitive installed equipment – such as panel PCs – from damage during cleaning. In this way, plant downtime and expensive repairs are effectively avoided. Properties: ● Viewing window frame with a 10° all-round chamfer so that fluids can drain off reliably ● Hinge optionally at the top, right or left ● Silicone seal on the outside, no gap ● Replaceable seal ● Seal dyed blue to clearly distinguish it from foodstuffs ● Replaceable viewing panel Material: Stainless steel 1.4301 Surface finish: Surface roughness RA< 0.8 μm Interface extension HD For extending the internal enclosure interfaces – e.g. from industrial PCs – up to the outside of the enclosure. Benefits: ● Rapid access for maintenance work ● The protection category of the enclosure is preserved. ● Captive protective cap Material: Stainless steel 1.4305
  • 14. Premium Line Resistant to high-pressure cleaning 14 Rittal Hygienic Design The perfect solution for ● Pressure washer resistance (protection category IP 69K). The seal lies between two seals and is optimally com- pressed by the screw fastening. ● Suitability for clean rooms Optional screw fastening to comply with high standards in the food and hygiene sectors: external with hex screws, internal with plastic bungs. ● Optimum EMC conditions The labyrinthe seal achieves a particularly high level of RF shielding of the enclosure. Accessories: Rear panel support, interior CP 6682.000. Holds the rear panel against the enclosure at a 90° angle when it is flipped down; easily removed if required. Material: Stainless steel 1.4301 (AISI 304) Surface finish: Brushed, grain 240 Protection category: IP 69K to DIN 40 050-9 Cover or rear panel screw-fastened: optional, included with the supply. 1 Screw head on the outside ... 2 ... or plastic bungs on the outside with concealed screws 1 2 Premium Line KL, IP 69 K For detailed information, see Catalogue 32, page 306 and 1221. Dimensions mm Model No. KL Width Height Depth 150 150 80 1024.010 150 150 120 1024.020 300 200 120 1024.030 400 300 120 1024.040 To order in stainless steel 1.4404 (AISI 316L), please add extension .5X0 to the Model No. Delivery times available on request. Other sizes available on request.
  • 15. Resistant to high-pressure cleaning Premium Line 15Rittal Hygienic Design Premium Panel, IP 69 K For detailed information, see Catalogue 32, page 311 and 1222. Dimensions mm Support arm connection Model No. CP Width Height Depth For installation panel W x H Installation depth Operating housing Keyboard housing Operating housing Operating housing Keyboard housing Operating housing Keyboard housing With keyboard housing 530 460 200 120 482.6 mm (19˝) x 354.8 mm (8 U) 482.6 mm (19˝) x 177 mm (4 U) 115 front 58 rear 63 Top 6680.000 530 460 200 120 115 front 58 rear 63 Bottom 6680.010 530 460 200 220 215 front 58 rear 63 Top 6680.100 530 460 200 220 215 front 58 rear 63 Bottom 6680.110 Without keyboard housing 530 360 – 120 482.6 mm (19˝) x 310 mm (7 U) – 115 – Top, or bottom by rotating the enclosure 6681.000 530 360 – 220 215 – 6681.100 To order in stainless steel 1.4404 (AISI 316L), please add extension XX5X.XXX to the Model No. Delivery times available on request. Other sizes available on request Premium TFT 17˝, IP 69 K Technical specifications: Resolution max.: 17˝: 1280 x 1024 pixels, VGA + SXGA non-interlaced Colours: 16.2 million Brightness: 300 cd/m2 Reading angle: 150° horizontal, 130° vertical Contrast ratio: 500 : 1 MTBF backlight: 50,000 h Voltage: 12 V DC On Screen Display (OSD) at rear VGA input: 15 pin D-Sub Operating temperature: 0°C to +50°C Power pack SM 6450.050 and connection cable SM 6450.060, see Cat. 32, page 1134. Support arm connection W mm H mm T1 mm T2 mm Model No. SM Bottom 530 360 120 70 6450.100 Top 530 360 120 70 6450.110 To order version in stainless steel 1.4404 (AISI 316L) please use Model No. SM 6450.5XX. Delivery times available on request. Pressure relief stopper Especially when enclosures are exposed to changing climatic conditions (e.g. with outdoor siting), condensation may form in sealed enclosures due to pressure differences. The integral sealing membrane largely prevents such pressure differences and hence condensation; additionally, it also prevents the ingress of moisture from the outside. Installed in vertical surfaces to protect against dirt. Technical specifications: ● Air permeability up to 120 litres/hour with a pressure difference of 70 mbar ● Protection category IP 66, 68, 69K ● Connection thread M12 x 1.5 ● For fitting in wall thicknesses up to 4 mm Material: Polyamide Colour: Similar to RAL 9005 (black) Supply includes: Lock nut Packs of Model No. SZ 5 2459.500
  • 16. Compact enclosures AE 16 Rittal Hygienic Design Stainless steel keyboard 19˝/4 U based on the piezo system. With this innovative technology, merely tapping lightly with your finger is sufficent to initiate switch- ing. There are no edges, cracks or hollows, as with conventional keyboards. It is therefore parti- cularly well-suited for the food industry (compact enclosures Hygienic Design, see page 7). Technical specifications: Dimensions of front panel: 482.6 x 177 x 3.7 mm Installation depth 25 mm 105 keys Actuator travel/force: 0 mm/0.7 N Service life: 10 million switching cycles Keypad: Abrasion-resistant electrolyte lettering Operating temperature: –25°C to +55°C PS/2 and USB connection German layout Material: Stainless steel 1.4301 Protection category: IP 69K to DIN 40 050-9 Supply includes: Connection cable, length 1.8 m, with PS/2 connector and hex nuts. Rittal service: Country-specific layout available on request. 464.6 482.6 (19˝) 5 159 479.6 170 182.3 174 1.5 104 7 1 32 4 177(4U) > Model No. SM Stainless steel keyboard 6446.010 Front panel cut-out Seal Holes for fastening bolts Contact surface 1 2 3 4 Optical mouse IP 68 Input device for all areas where heavy contamination is unavoidable or where exceptional standards of hygiene are crucial. Benefits: ● High-quality silicone surface. ● Integral optical scanning. ● Sealed on all sides. ● Mechanical operating parts completely impervious to dirt. ● Easy to clean. ● Also suitable for use in hygiene-sensitive areas. Technical specifications: ● Optical scanning (with 800 dpi resolution) ● Silicone enclosure with high-quality surface coating ● Disinfectable ● Application area: from –40°C to +90°C Protection category: IP 68 to EN 60 529 Material: Silicone top Colour: Similar to RAL 9002 Supply includes: USB connection cable, cable length 1800 mm. Note: Not suitable for use in the meat processing industry. Accessories: Connector gland (SZ 2400.500), see Cat. 32 page 1057. Support for mousepad (SM 2381.000), see Cat. 32, page 1145. Connection Packs of Model No. SM USB 1 6445.100 PS2 – on request
  • 17. A partner for your plant Liquid cooling concepts 17Rittal Hygienic Design When a cooling water system is installed in the production plant or hall, the cheapest and most hygienic method of enclosure climate control is to use air/water heat exchangers. Assuming there is no cooling water system available, the required cooling output for the individual heat exchangers, either decentralised or centralised, can be provided via recooling systems, which may be installed outside of the open process. In certain cases, e.g. for frequency converters, water cooling may also be provided inside the enclosure. To this end, drive modules from a wide range of manufacturers with a cold plate at the rear may be mounted directly on the DCP water- cooled mounting plate. If the potential heat loss of the cold plate is not used com- pletely for converters, the enclosure internal temperature may be reduced with the add-on or stand-alone DCP cooling unit. Operating housings may be water-cooled using DCP panel cooling. The complete solution of enclosure or operating housing plus cooling concept is supplied by Rittal and ensures a clean, functional solution for the food industry and related sectors. Air/water heat exchangers Design: Fully wired ready for connection, plastic mounting trough, sheet steel cover spray-finished in RAL 7035, also available in stainless steel 1.4301 (AISI 304) on request. Protection category: IP 55, on request IP 65 For detailed information, see Cat. 32, from page 675. Recooling systems Fully wired and plumbed ready for connection, sheet steel enclosure, spray finished in RAL 7035, also available in stainless steel 1.4301 (AISI 304) on request. For detailed information, see Cat. 32, from page 654.
  • 18. Liquid cooling concepts A partner for your plant 18 Rittal Hygienic Design DCP mounting plate Power electronic components can be cooled particularly effectively using the liquid cooled plate. Heat losses are cleverly dissipated from the enclosure or housing without compromising the high enclosure protection category in any way. Furthermore, liquid cooling is both quiet and a thousand times more efficient than heat dissipation via air. The Rittal DCP Cold Plate has received type- tested certification from the TÜV inspection authority and is approved for pressures up to 10 bar. ype Teste 3 basic variants are available for the configuration of various power electronic components: Siemens SINAMICS S 120 series Danfoss frequency converter VLT௡ Automation Drive FC300 1. With drilling surface for the customer to drill their own tapped holes (core hole max. 12 mm) 2. With variable wire clamp system as an accessory for clamping surface: ● All-round ● Side ● Top and bottom 3. Manufacturer-specific Other sizes and manufacturers available on request. For detailed information, see Cat. 32, from page 731. Rittal DCP CoolingUnit The CoolingUnit is available in two variants. As a stand-alone unit with press-fitted cooler tubes, or as an add-on in conjunction with a Rittal Cold Plate. The optional housing for the cooler ensures even more efficient air routing and thus reliable cooling of the air inside the enclosure. Detailed information and accessories, see Cat. 32, from page 735 and also at www.rittal.com/dcp DCP CoolingUnit – Add-on DCP CoolingUnit – Stand-alone Rittal DCP PanelCooling This integrated PanelCooling solution was developed by Rittal for optimum, space-saving cooling of operating housings. Heat losses of approx. 150 – 350 W can be dissipated without the need for external add-ons. The high protection category of the enclosure is retained, thanks to the fluid connection at the rear of the panel. Detailed information and accessories, see Cat. 32, from page 733 and also at www.rittal.com/dcp
  • 19. Technical details Hygienic Design 19Rittal Hygienic Design B1 i.L. B2 78H4 200 B3 70 80 3535 158 (10)(10) (10) B4 2 3 1 3 2 3 3 4 H2 H1 T2 T1 T3 i.L.H3 50 400 H6 Z 5 5 B1 i.L. B2 368 575 H4 200 H5 90 3535 (10) (10) 60 (10) B4 7 4 6 7 7 6 7 T2 T1 i.L.H3 H1 H2 T3 50 H5 175 H6 Z H6 Z 9090 740 12.5 1155 18 700 01 02 03 04 07 08 09 10 11 01 02 03 04 07 08 09 10 11 05 06 05 06 1125 Ø 10 90 90 700 739 930 955 12 01 02 03 04 05 06 07 08 09 01 02 03 04 05 06 07 08 09 Ø 10 F2 F1 90 90 G2 G1 01 02 01 02 03 03 Ø 10 122 138 162 9 122 225 260 275 02 0101 02 Ø 9 Ø 6.5 Compact enclosures HD, single-door Page 7 Model No. HD Width dimensions mm Height dimensions mm Depth dimensions mm Mounting plates mm Material thickness mm Stainless steel B1 B2 B3 B4 H1 H2 H3 H4 H5 H6 T1 T2 T3 F1 F2 G1 G2 Enclosure Door Mounting plate 1302.X00 220 170 – 200 350 437 260 – – 293 155 162 113 – 130 – – – – 1.25 1.5 2.0 1306.X00 390 340 – 370 430 549 340 240 – 373 210 217 168 – 185 334 295 355 330 1.5 1.5 2.0 1307.X00 510 460 375 490 550 669 460 360 – 493 210 217 168 – 185 449 410 470 445 1.5 1.5 2.5 1308.X00 390 340 275 370 650 769 560 460 – 593 210 217 168 – 185 334 295 570 545 1.5 1.5 2.5 1310.X00 610 560 475 590 650 769 560 460 – 593 210 217 168 – 185 549 510 570 545 1.5 2.0 2.5 1316.X00 810 760 – 790 1050 1221 960 280 800 993 300 307 258 – 275 – – – – 1.5 2.0 3.0 1317.X00 810 760 – 790 1250 1421 1160 480 1000 1193 300 307 258 – 275 – – – – 1.5 2.0 3.0 1320.X00 610 560 – 590 430 601 340 240 – 373 300 307 258 – 275 549 510 355 330 1.5 1.5 2.5 H1 = H2 = H3 = H4 = H5 = H6 = Enclosure height, front Enclosure height, rear Clearance height of enclosure Spacing between fasteners Separation height of threaded bolts on the door Height of door T1 = T2 = T3 = Depth between rear panel and door Overall depth Possible mounting depth (mounting plate assembly) For HD 1302.X00 For HD 1306.X00, HD 1307.X00, HD 1308.X00, HD 1310.X00, HD 1320.X00 For HD 1307.X00, HD 1308.X00, HD 1310.X00 1 2 3 Max. installation area, door For HD 1308.X00, HD 1310.X00 4 5 For HD 1316.X00 For HD 1317.X00 6 7 HD 1317.X00 HD 1316.X00 HD 1306.X00, HD 1307.X00, HD 1308.X00, HD 1310.X00, HD 1320.X00 HD 1302.X00 Mounting plate F1 = F2 = G1 = G2 = Mounting plate width Separation width of attachment bolts Mounting plate height Separation height of attachment bolts Enclosure B1 = B2 = B3 = B4 = Overall width Clearance width of enclosure Separation width of threaded bolts on the door Width of door HD 1302.X00, HD 1306.X00, HD 1307.X00, HD 1308.X00, HD 1310.X00, HD 1320.X00 HD 1316.X00, HD 1317.X00
  • 20. R Switch to perfection Small enclosures ⅐ Compact enclosures ⅐ Large enclosures Products for the human/machine interface ⅐ Console systems Material: sheet steel, stainless steel, aluminium and plastic Industrial network technology ⅐ Input and signalling devices Solutions for EMC and Ex ⅐ Cable glands All in all – solutions from Rittal Rittal has one of the largest ranges of enclosures available for immediate delivery. However, Rittal also supplies inte- grated solutions – up to Level 4. This comprises mechanical installation, power supply, electronic components, climate control and central monitoring. For all of your requirements. Fully assembled and functional. Wherever in the world you develop and implement solutions for yourself and your customers, we are close at hand. The global alliance between production, distribution and service guarantees closeness to the customer. Worldwide! 01/09⅐E973 Electronic Packaging IT Solutions Communication Systems System Climate Control Power Distribution Industrial Enclosures Rittal GmbH & Co. KG ⅐ Postfach 1662 ⅐ D-35726 Herborn Telephone: +49(0)2772 505-0 ⅐ Telefax: +49(0)2772 505-2319 ⅐ eMail: info@rittal.de ⅐ www.rittal.com
  • 22. Hygienic Design Terminal boxes HD Rittal terminal boxes in Hygienic Design (HD) have been tailored for optimum incorporation into machinery and equipment for use in open processes in the food industry and are thus a perfect complement to the proven compact enclosures HD. Extra cleanliness guaranteed! Rittal Limited,Braithwell Way, Hellaby Ind Estate, Hellaby, Rotherham, S. Yorkshire, S66 8QY Telephone: 01709 704000 Fax: 01709 701217 E-mail: information@rittal.co.uk Web: www.rittal.co.uk Benefits: Simple cleaning ● Inclined surfaces: 3° on all sides, 10° on the cover ● All-round gap-free silicone seal between enclosure and cover ● Hygiene-compliant hexagon locks Easy assembly ● Quick-release cover locks ● Simple replacement of the silicone seal Component installation ● Hole pitch of 6.25 mm for greater flexibility ● KL support rails and mounting plates can be fitted directly 04/2010 Width front mm Packs of 150 150 200 300 400 rear mm 172 177 227 327 427 Height front mm 150 150 200 200 200 rear mm 172 177 227 227 227 Depth mm 80 120 120 120 120 Model No. HD 1 1670.600 1671.600 1672.600 1674.600 1675.600 Accessories Wall spacer 50 mm 1 4000.100 4000.100 4000.100 4000.100 4000.100 Mounting plate 1 1560.700 1560.700 1562.700 1563.700 1564.700 Support rail TS 35/7.5 10 2314.000 2314.000 2315.000 2316.000 2317.000 Material: Enclosure and cover: Stainless steel 1.4301 (AISI 304) 1.5 mm Mounting bracket: Sheet steel, zinc-plated, 2.0 mm Quick-release locks: Stainless steel 1.4301 (AISI 304) Seal: Silicone, compliant with FDA 21 CFR 177.2600 Surface finish: Enclosure and cover: Brushed finish, grain 400, RA < 0.8 μm Seal: Blue, dyed (RAL 5010) Protection category: IP 66 to EN 60 529 Scope of delivery: Enclosure with unbroken sur- face, cover, mounting bracket (pre-assembled), seal and quick-release locks (enclosed). Accessories: Cable glands HD, see Rittal catalogue 32, page 1056. Detail drawing can be found on the Internet.
  • 23. R hmi_hd.fm Seite 2 Freitag, 10. Juli 2009 12:47 12 Command Panel HD – Extra cleanliness guaranteed
  • 24. Command Panel HD with pedestal Switch to perfection 07/09 Rittal Limited ⅐ Braithwell Way ⅐ Hellaby Industrial Estate ⅐ Hellaby ⅐ Rotherham ⅐ S Yorks S66 8QY Tel.: (01709) 704000 ⅐ Fax: (01709) 701217 ⅐ www.rittal.co.uk ⅐ eMail: information@rittal.co.uk Basic enclosure: ● W x H x D: 610 x 650/823.3 x 300 mm ● Integrated viewing window, flush-mounted with silicone seals, W x H: 380 x 313 mm ● PC shelf with nylon loop to secure the PC ● Inner door with VESA mount for TFT monitor, W x H: 400 x 360 mm ● Enclosure with unbroken surfaces (preparation for cable entry upon request) Keyboard housing: ● W x H x D: 608 x 45/62 x 200 mm ● Connection to the basic enclosure via tubes, length 60 mm ● Stainless steel keyboard 19˝/4 U, piezo technology, UK keyboard layout (other country variants upon request), USB connecting cable ● Modular optical trackball unit, 51 mm dia, with 3 buttons and USB connecting cable Pedestal: ● Comprising a base plate, two tubular legs Ø 70 mm and two enclosure mounts, with fully welded joints between all parts ● Height: 996 mm ● Base plate W x D: 600 x 400 mm with floor fixing holes Complete solution for use in the food and drinks industry. Prepared for installation of a standard PC up to 160 x 500 x 500 mm and a TFT monitor up to max. 17˝ with VESA mount. Where foods are handled in a continuous process, it is often necessary to provide control and monitoring of production. Such areas are particularly critical with regard to hygiene, as the presence of an operator can easily lead to cross-contam- ination, and thus special hygienic solutions are imperative. Rittal’s pedestal-mounted command panel is ideally suited to this task. A further benefit: The modularity of the PC hard- ware guarantees the cost-effective replacement of individual components should this become necessary. Also required: Socket strip, see Catalogue 32, pages 1038 to 1043. Stainless steel cable gland, Hygienic Design, see Catalogue 32, page 1056. Possible alternative: As an alternative to the pedestal, wall mounting is possible, e.g. by way of a 50 mm wall spacer bracket HD 4000.100 (see Catalogue 32, page 301). Model No. Basic enclosure with keyboard housing 4000.009-BM NuG 100 Pedestal 4000.029-BM NuG 500 hmi_hd.fm Seite 1 Freitag, 10. Juli 2009 12:47 12 WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 477 5371 TEL 0044 117 977 4647 FAX 0044 977 5582 WWW.THORNEANDDERRICK.CO.UK