SlideShare a Scribd company logo
1) DO'S AND DON'T'S 2) Protection distance
2 CAUTIONS ON INSTALLATION
・Do not install the unit on
places where it may be
splashed by dirty water or
direct ocean spray.
・Do not install the unit on
unsteady surfaces.
・Do not install the unit at places
where it may be interrupted by
obstacles such as trees.
・Avoid strong light from the
sun, automobile headlights
etc. shining on transmitter
and receiver directly. (Avoid
light within ±2°degrees of
optical axis.)
1) Basic connection
The equipment must be powered from an LPS in accordance with EN60950-1 : 2001
2) When two or more sensors are connected to the same line.
3) When two or more sensors are connected to
separate lines.
4) When two sensors are stacked and connected to
the same line.
TR RE
Power
(DC12V)
Power
(DC12V)
Power
(DC12V)
Power
(DC12V)
Alarm signal
Alarm signal
1
Alarm signal
2
Alarm signal
(N.C.)
Alarm signal
(N.C.)
(Control panel)
(Control panel)
(Control panel)
(Control panel)
}
}
Wiring
}
}
}
}
}
}
}
(CH3)
(CH1)
TR RE TR RE
TR RE TRRE
TRRE
B
Up to 50m
Up to 100m
Up to 200m
1.2m
(A=50m)
2.4m
(A=100m)
5.0m
(A=200m)
PB- 50HF-KH
PB-100HF-KH
PB-200HF-KH
AModel
B
Protection distance A
②
①② ①②
①② ① ② ③ ④
① ② ③ ④①②
①②③④ ①②③④
①②③④① ② ③ ④① ② ①② ①②①②③④
Power(DC12V)
Alarm signal
Environmental signal
(N.O. N.C. selectable)
External control
switch
(Control panel)
}
}
}
○+
○−
5) When environmental output and remote alarm memory are used.
6) Wiring distance
Max. wiring distance when two or more sets are connected is the above value divided by the number of sets.
The signal line can be wired to a distance of up to 6,600ft. (2,000m) with AWG 20 (dia.0.8mm) telephone wire.
Note : 1)
2)
TR RE
wire size
PB-50HF-KH PB-100HF-KH PB-200HF-KH
12V DC 24V DC 12V DC 24V DC 12V DC 24V DC
Model
Power voltage
Terminal arrangement
Mounting
●Install the unit to a beam tower.
 Some towers could block the beam within its
case when the mirror is turned by ±90°
vertically.
 Please refer to the instruction manual of the
beam tower carefully before use.
●Beam sensor's reflecting mirror can be moved
horizontally (±90 degrees) and vertically
(±10 degrees) allowing the unit to work in all
directions.
±10°
±90°
+
①
②
③
④
⑨
⑩
⑪
①
②
① ② ① ② ③ ④
⑨ ⑩ ⑪
−
+
−
[Transmitter]
Beam sensor
[Receiver]
30V (AC/DC)
0.5A MAX.
N.C. or N.O.
Alarm N.C. or N.O.
30V (AC/DC) 1A MAX.
Environmental
Alarm memory
Power
12 to 30V DC
(non-polarity)
Power
12 to 30V DC
(non-polarity)
90°
③
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm)
AWG17 (Dia.1.1mm)
AWG16 (Dia.1.25mm)
AWG15 (Dia.1.4mm)
AWG14 (Dia.1.6mm)
800' (244m)
1250' (381m)
1500' (457m)
1950' (595m)
2500' (750m)
3200' (976m)
5600' (1710m)
8800' (2680m)
10500' (3200m)
13500' (4000m)
17000' (5180m)
22500' (6860m)
660' (200m)
1100' (335m)
1350' (400m)
1750' (534m)
2200' (670m)
2900' (884m)
5100' (1550m)
7900' (2410m)
9600' (2930m)
12000' (3660m)
15500' (4730m)
20000' (6000m)
630' (192m)
1000' (300m)
1200' (366m)
1550' (473m)
1950' (595m)
2550' (777m)
4400' (1340m)
6900' (2100m)
8400' (2560m)
10500' (3200m)
13500' (4000m)
17500' (5340m)
①Look through view finder on either side upper transmitter
optical unit and move until receiver unit is visible.
②Repeat the procedure for lower optical unit and then repeat on
receiver.
●Procedure detail
●Function options
③nAttach the shading plates to the lower optics of both
transmitter and receiver.
④Turn the receiver beep switch "ON".
⑤Adjust the optics with the adjustment screws until highest tone
is reached.
(Note : There will be no sound if the sensitivity LED is lit.)
⑥Check output voltage by monitor output.
A precise alignment can be accomplished by using a digital volt
meter.
⑦Reverse the procedure, i.e. attach shading plates to upper optics
of transmitter and receiver and repeat adjustment.
⑧After adjustment, replace
the shading plates in the
storage areas of
transmitter and receiver.
View finder
Adjustment dial
Horizontal angle
adjustment screw
Vertical angle
adjustment screw
Location
Transmitter and receiver
Transmitter only
Receiver only
Beam frequency
Beam power
Beep switch
Alarm memory
Environmental output
Response time
Alarm output
Functions Function switches
□1CH □2CH □3CH □4CH
□H □L
□N.O.   □N.C.
□0.05sec. □0.3sec.
□0.7sec. □Others
□ON   □OFF
□N.O.  □N.C.
□Timer  □Remote
Voltage reading
2.7V or more
2.0V to 2.7V
2.0V or less
Sensitivity
Best
Good
Poor, re-adjust
Digital volt meter
Sensitivity LED
Beep switch
Monitor jack
3SET-UP OF FUNCTIONS AND BEAM ALIGNMENT
1) Supply power with covers off.
2) Set function options according
to the right table.
3) Adjust optical angle.
1) Alarm LED only.
2) Alarm LED and beep tone. (Walk test mode)
Set the beep switch to "ON", then a beep tone will be
issued upon beam blockage for five minutes after the Auto
gain is locked.
After installation and beam alignment, check operation by walk test.
Two methods may be used.
Lights
Lights Lights
1)Check by alarm LED
RE RETR TR
2)Check by walk test mode
Lights
Beep
4OPERATION CHECK
Rock spacer
(Put "A" side in)
Place the covers on the beam line before insert the
lock spacer so as to get the same beam strength as
the covers are attached.
⑨After beam alignment, place the covers on the beam
line. Then insert a lock spacer to the micro switch part
for gain lock on the receiver unit.
⑩5sec. after, sensitivity margin will be automatically set
and gain lock will be completed after beep sound is
heard once.
If the beep sound is heard in an intermittent way,
sensitivity is not good.
In this case, remove the lock spacer and adjust beam
alignment again.
(Please refer to 5.5 Auto-gain lock function.)
TX
RX
④
The combination of 1CH and 3CH or 2CH and 4CH (do not use adjacent channels) are recommended to avoid crosstalk between units which
are stacked, in-line, or other configurations which have the potential of spillover transmission from one beam to another.
Set the frequency level as illustrated.
Make sure both transmitter and receiver of pair are set to the same channel.
The use of voltmeter for alignment is recommended to ensure highest level of
stability.
For stacked protection, make sure that beam sensors to be installed are the
same model with the same beam power selection.
Consult with TAKEX distributor or TAKEX regional office about the frequency
selection for installations not mentioned in this instruction manual.
Inappropreate choice of frequency may cause malfunction.
4. Four channel frequency selection
1CH 2CH 3CH 4CH
Note : 1)
1. Alarm memory function (Receiver)
The alarm memory LED indicates which sensor has triggered when two or
more sensors are placed on a zone.
An audible tone in addition is optional. Reset can be timer or remote.
2. Alarm output
N.C. or N.O. signal output is selectable.
If alarm memory function is not used, set the memory
selector to "Remote" and leave receiver terminal ⑪
unconnected.
3. Beam power selection (Transmitter)
Up to 83' (25m)
Up to 248' (75m)
Up to 495' (150m)
Connect / disconnect terminal ⑪ and ○+ terminal (① or ②)
1) Auto-reset
2)Manual60min.(re-trigger)
5min.
Alarm output
Connect terminal ⑪ and ○+ terminal (① or ②)
Memory LED
5min.
55min.(flickering)
N.C.N.O.
Alarm output selectable switch
(Initial setting:N.C.)
〔Alarm memory selectable switch〕
← →
Auto-reset Manual
Alarm memory selectable switch(Initial setting:Manual)
〔Alarm output selectable switch〕
← →
Alarm output
Alarm memory
input
Memory LED
Short ShortShort
Open Open
Beep sound at
(Beep switch ON)
Lights
5FUNCTIONS DESCRIPTION
Note :
1) Line protection
1CH
TR
1CH
RE
3CH
TR
3CH
TR
3CH
RE
4CH
TR
4CH
RE
3CH
RE
1CH
TR
1CH
RE
1CH
RE
3CH
RE
2CH
RE
4CH
RE
2CH
RE
4CH
RE
1CH
RE
3CH
RE
2CH
TR
2CH
RE
1CH
TR
3CH
TR
1CH
RE
1CH
TR
1CH
RE
1CH
TR
1CH
TR
1CH
TR
2CH
TR
3CH
TR
4CH
TR
2CH
TR
1CH
TR
4CH
TR
3CH
TR
3CH
TR
1CH
TR
3CH
TR
1CH
RE
1CH
RE
3CH
RE
3CH
RE
1CH
RE
3CH
RE
3CH
TR
3CH
RE
2) 2-stacked protection
3) Line and 2-stacked protection
4) Perimeter protection
5) Perimeter double stacked protection
L H
PB- 50HF-KH
PB-100HF-KH
PB-200HF-KH
Above 83' (25m) Up to 165' (50m)
Above 248' (75m) Up to 330' (100m)
Above 495' (150m) Up to 660' (200m)
⑤
2)
3)
OK
not good
Run at full speed Walk with quick steps Walking
Response time:
0.05 sec.
Response time:
0.3 sec.
Response time:
0.7 sec.
Response time
adjustment
(Beam sensor)
(0.3)
0.7(sec.)
0.05(sec.)
5. Auto-gain lock function
6. Tone indicator
7. Response time
8. Environmental check
2) A "beep" tone is issued from the receiver approximately five seconds after the lock spacer is put into position.
This tone indicates the Auto-gain has been set. Refer to the chart below.
1) The auto-gain lock serves to standardize the responsiveness and tolerance level of the units regardless of varying distance in an
installation.
Less than protection distance
Max. Protection distance
Tone
One pulse
(beep)
Continuous
tone
(20 seconds)
Indicates Result
The environmental signal is initiated if the beam reception level is reduced by
poor weather conditions (dense fog or torrential rain etc.).
N.C. or N.O. signal output is selectable.
(Contact capacity 30V (AC/DC) 1A MAX.)
Adjust response time as follows. The unit does
not detect the passing object faster than the
response time set.
If the response time is set extremely long, the
unit may be unable to detect human pattern.
Adjust a little longer response time in a site
where large passing objects such as birds,
newspapers or falling leaves may move.
Beam alignment ON
ON
ON
N.O. N.C.
Alignment tone switchTest / Signal Description
RemedyCause
Other condition
Auto-gain lock
Walk test
Alarm memory
Reception strength monitored.
Tone pitch increases as reception improves.
Note : No tone is given if sensitivity attenuation
LED is lit or if the lock spacer is attached.
1. Remove obstructions and replace cover.
Check beep tone.
2. Check beam power setting at transmitter
with cover off and re-adjust beam
alignment.
1. Beam is interrupted once cover is
replaced.
2. Beam is misaligned and sensitivity
attenuation LED lights.
Optimal sensitivity has
been set.
Optimal sensitivity
cannot be set.
Short tone indicates lock is set.
Continuous tone (20sec.) indicates readjustment.
Lock spacer detached
About 5sec. after the lock
spacer is attached.
For approx. 5min. after gain
is locked.
Set to manual memory
Tone is linked to alarm LED.
Both trip simultaneously.
"Beep" is indicated if alarm condition occurs.
Environmental output selector
(Initial setting:N.C.)
A tone is generated regardless of whether "beep" (alignment tone) switch is set to ON or OFF.
The auto-gain setting is locked in even if power is disrupted.
If the lock spacer is detached while power is supplied or if power is discontinued , the auto-gain automatically resets to maximum
sensitivity.
Note : 1)
2)
3)
⑥
6TROUBLESHOOTING
7 SPECIFICATIONS
Symptom Possible cause Remedy
Transmitter LED does
not light
1. No power supply
1. No power supply
2. Bad wiring connection, or broken wire, short 2. Check wire
2. Check wire
1. Turn on the power
1. Turn on the power
4. 4 photoelectric beams are not broken simultaneously
3. Photoelectric beam is reflected on another object and sent
into the receiver
2. Bad wiring connection
4. Interrupt 4 beams simultaneously
3. Remove the reflecting object or change the place for
installation
Receiver LED continues
to light (An alarm does
not stop)
Receiver LED does not
light when the beam is
broken
3. Optics of units are soiled
4. Frequency channel setting on transmitter does not match
with that on receiver
2. Shading object between transmitter and receiver
1. Alignment is off
4. Readjust to be the same channel
3. Clean the optics with a soft cloth
2. Remove the shading object
1. Check and adjust again
8. Small animals may pass through the 4 photoelectric beams
9. Installation site or installation height is not appropriate
7. Improper alignment
6. Optics of units are soiled
5. Unstable installation of unit
4. A large electric notise source such as power machine, is
located nearby transmitter and receiver
3. Shading object between transmitter and receiver
2. Change of supply voltage
1. Bad wiring connection
8. Change installation site or environments
9. Re-adjust the installation site or height
7. Check and re-adjust
6. Clean the optics with soft cloth
5. Stabilize
4. Change the place for installation
3. Remove the shading object
2. Stabilize supply voltage
1. Check again
Intermittent alarm
Photo electric beam sensor
PB-50HF-KH
165ft. (50m) or less
1650ft. (500m)
(tenfold margin distance)
LED (pulsed beam by LED)
Double modulation
Photoelectric beam
0.05sec. to 0.7sec. (Variable at pot)
Dry contact relay output N.O. / N.C.
Contact action : Interruption time + delay time (approx. 2sec.)
Contact capacity : 30V (AC/DC) 1A
Dry contact relay output N.O. / N.C.
Contact capacity : 30V (AC/DC) 0.5A
12 to 30V DC
When alarmed 60mA or less
・Transmitter : 15mA or less
・Receiver : 45mA or less
When adjusted 95mA or less
Alignment tone switch, Attenuation LED, Monitor jack,
Alarm memory indication, Modulation frequency selectable (4stage),
Environmental check, Automatic gain control (AGC) circuit,
Transmitter 10.6oz (300g) Receiver 14.1oz (400g)
ABS resin
Type
Model
Protection distance
Max. arrival distance
Infrared beam
Detection system
Response time
Alarm signal
Environmental signal
Supply voltage
Power consumption
Functions
Weight
Appearance
PB-100HF-KH
330ft. (100m) or less
PB-200HF-KH
660ft. (200m) or less
3300ft. (1000m)
(tenfold margin distance)
6600ft. (2000m)
(tenfold margin distance)
When alarmed 70mA or less
・Transmitter : 25mA or less
・Receiver : 45mA or less
When adjusted 105mA or less
When alarmed 85mA or less
・Transmitter : 40mA or less
・Receiver : 45mA or less
When adjusted 120mA or less
⑦
No.05-526 1110
⑧
In Japan
Takex America Inc.
Unit 16/35 Garden Road, Clayton,
3168 Victoria, Australia
Tel : 03-9546-0533
Fax : 03-9547-9450
Takenaka Engineering Co., Ltd.
83-1, Gojo-sotokan, Higashino,
Yamashina-ku, Kyoto 607-8156, Japan
Tel : 81-75-501-6651
Fax : 81-75-593-3816
http : // www. takex-eng. co. jp /
Takex America Inc.
230E, Caribbean Drive
Sunnyvale, CA 94086, U.S.A.
Tel : 408-747-0100
Fax : 408-734-1100
http : // www. takex. com
Takex Europe Ltd.
Takex House, Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel : (+44) 01256-475555
Fax : (+44) 01256-466268
http : // www. takexeurope. com
In the U.S. In the U.K.In Australia
EXTERNAL DIMENSIONS
8
SPECIAL NOTES
9This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures :
---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment
into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio / TV
technician for help.
WARNING : Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate the equipment.
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or
failure caused by Acts of God (including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than
those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts
returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for
product repairs made after our Warranty period has expired.
MOUNT HOLE
13.78"(350mm)
3.46" (88mm)
2.36"(60mm)
2.83" (72mm)
4-φ0.12" (φ3mm)
5.12"(130mm)

More Related Content

What's hot

Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
Domotica daVinci
 
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
Domotica daVinci
 
Manual dimmer benext us
Manual dimmer benext usManual dimmer benext us
Manual dimmer benext us
Domotica daVinci
 
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
Domotica daVinci
 
Zipato zipabox backup_module_user_manual
Zipato zipabox backup_module_user_manualZipato zipabox backup_module_user_manual
Zipato zipabox backup_module_user_manual
Domotica daVinci
 
Adcmt 8230 e-optical_power_meter_denkei
Adcmt 8230 e-optical_power_meter_denkeiAdcmt 8230 e-optical_power_meter_denkei
Adcmt 8230 e-optical_power_meter_denkei
NIHON DENKEI SINGAPORE
 
Tacstickmanual
TacstickmanualTacstickmanual
Tacstickmanual
Ricardo Ortiz
 
Manual eurotronic comet_en
Manual eurotronic comet_enManual eurotronic comet_en
Manual eurotronic comet_en
Domotica daVinci
 
Brosur Total Station Sokkia Cx series
Brosur Total Station Sokkia Cx seriesBrosur Total Station Sokkia Cx series
Brosur Total Station Sokkia Cx series
Rega Surveyor
 
Jual Total Station Sokkia CX-101 Call Fery 087885028163
Jual Total Station Sokkia CX-101 Call Fery 087885028163Jual Total Station Sokkia CX-101 Call Fery 087885028163
Jual Total Station Sokkia CX-101 Call Fery 087885028163
alam survey
 

What's hot (10)

Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
Ph pat02 - zipato flood multisensor 3 in 1 user manual v1.0
 
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
 
Manual dimmer benext us
Manual dimmer benext usManual dimmer benext us
Manual dimmer benext us
 
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
ZIP Pan03 - Zipato micromodule single switch max.load 11 a user manual v1.0
 
Zipato zipabox backup_module_user_manual
Zipato zipabox backup_module_user_manualZipato zipabox backup_module_user_manual
Zipato zipabox backup_module_user_manual
 
Adcmt 8230 e-optical_power_meter_denkei
Adcmt 8230 e-optical_power_meter_denkeiAdcmt 8230 e-optical_power_meter_denkei
Adcmt 8230 e-optical_power_meter_denkei
 
Tacstickmanual
TacstickmanualTacstickmanual
Tacstickmanual
 
Manual eurotronic comet_en
Manual eurotronic comet_enManual eurotronic comet_en
Manual eurotronic comet_en
 
Brosur Total Station Sokkia Cx series
Brosur Total Station Sokkia Cx seriesBrosur Total Station Sokkia Cx series
Brosur Total Station Sokkia Cx series
 
Jual Total Station Sokkia CX-101 Call Fery 087885028163
Jual Total Station Sokkia CX-101 Call Fery 087885028163Jual Total Station Sokkia CX-101 Call Fery 087885028163
Jual Total Station Sokkia CX-101 Call Fery 087885028163
 

Similar to Takex PB-200HF-KH Instruction Manual

MultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
MultiSensor Strips Comfort - Z-Wave Plus- Sensative - ManualMultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
MultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
Domotica daVinci
 
User manual-475876
User manual-475876User manual-475876
User manual-475876
Dirson Volmir Willig
 
Andel Floodline - Instruction Manual
Andel Floodline - Instruction ManualAndel Floodline - Instruction Manual
Andel Floodline - Instruction ManualThorne & Derrick UK
 
Total Station Sokkia Set 62--65
Total Station Sokkia Set 62--65Total Station Sokkia Set 62--65
Total Station Sokkia Set 62--65
Agus Setiawan
 
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
vobetinha
 
Manual Omron E3X-HD Clearsensor optical messure
Manual Omron E3X-HD Clearsensor optical messureManual Omron E3X-HD Clearsensor optical messure
Manual Omron E3X-HD Clearsensor optical messure
RalCastillo23
 
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTHData Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
PT. Siwali Swantika
 
Evespring ST812 Z-Wave flood sendor manual in English
Evespring ST812 Z-Wave flood sendor manual in EnglishEvespring ST812 Z-Wave flood sendor manual in English
Evespring ST812 Z-Wave flood sendor manual in English
Domotica daVinci
 
Banner sensors fiber
Banner sensors fiberBanner sensors fiber
Banner sensors fiber
Gerardo Peña Sánchez
 
Takex FS-3500 Instruction Manual
Takex FS-3500 Instruction ManualTakex FS-3500 Instruction Manual
Takex FS-3500 Instruction Manual
JMAC Supply
 
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
ALAMSURVEY
 
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
ALAMSURVEY
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
alam survey
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
alam survey
 
Jual Total Station Sokkia CX-102 Call Fery 087885028163
Jual Total Station Sokkia CX-102 Call Fery 087885028163Jual Total Station Sokkia CX-102 Call Fery 087885028163
Jual Total Station Sokkia CX-102 Call Fery 087885028163
alam survey
 
Jual Total Station Sokkia CX-103 Call Fery 087885028163
Jual Total Station Sokkia CX-103 Call Fery 087885028163Jual Total Station Sokkia CX-103 Call Fery 087885028163
Jual Total Station Sokkia CX-103 Call Fery 087885028163
alam survey
 
jual total station sokkia cx
jual total station sokkia cxjual total station sokkia cx
jual total station sokkia cxRegi Bungsu
 
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
ALAMSURVEY
 
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
ALAMSURVEY
 

Similar to Takex PB-200HF-KH Instruction Manual (20)

MultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
MultiSensor Strips Comfort - Z-Wave Plus- Sensative - ManualMultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
MultiSensor Strips Comfort - Z-Wave Plus- Sensative - Manual
 
User manual-475876
User manual-475876User manual-475876
User manual-475876
 
Andel Floodline - Instruction Manual
Andel Floodline - Instruction ManualAndel Floodline - Instruction Manual
Andel Floodline - Instruction Manual
 
Total Station Sokkia Set 62--65
Total Station Sokkia Set 62--65Total Station Sokkia Set 62--65
Total Station Sokkia Set 62--65
 
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
Icel os 21-mesco_ao-1221_minipa_mo-1225_yb4328_2x5mv,20mhz_portable_oscillosc...
 
Manual Omron E3X-HD Clearsensor optical messure
Manual Omron E3X-HD Clearsensor optical messureManual Omron E3X-HD Clearsensor optical messure
Manual Omron E3X-HD Clearsensor optical messure
 
Es e 105
Es e 105Es e 105
Es e 105
 
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTHData Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
 
Evespring ST812 Z-Wave flood sendor manual in English
Evespring ST812 Z-Wave flood sendor manual in EnglishEvespring ST812 Z-Wave flood sendor manual in English
Evespring ST812 Z-Wave flood sendor manual in English
 
Banner sensors fiber
Banner sensors fiberBanner sensors fiber
Banner sensors fiber
 
Takex FS-3500 Instruction Manual
Takex FS-3500 Instruction ManualTakex FS-3500 Instruction Manual
Takex FS-3500 Instruction Manual
 
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 102   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 102 Murah Call. Somantri 087778355373
 
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 105 Murah Call. Somantri 087778355373
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
 
Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163Jual Total Station Sokkia CX-105 Call Fery 087885028163
Jual Total Station Sokkia CX-105 Call Fery 087885028163
 
Jual Total Station Sokkia CX-102 Call Fery 087885028163
Jual Total Station Sokkia CX-102 Call Fery 087885028163Jual Total Station Sokkia CX-102 Call Fery 087885028163
Jual Total Station Sokkia CX-102 Call Fery 087885028163
 
Jual Total Station Sokkia CX-103 Call Fery 087885028163
Jual Total Station Sokkia CX-103 Call Fery 087885028163Jual Total Station Sokkia CX-103 Call Fery 087885028163
Jual Total Station Sokkia CX-103 Call Fery 087885028163
 
jual total station sokkia cx
jual total station sokkia cxjual total station sokkia cx
jual total station sokkia cx
 
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 101   Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 101 Murah Call. Somantri 087778355373
 
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373Jual Total Ststion Sokkia CX 103  Murah Call. Somantri 087778355373
Jual Total Ststion Sokkia CX 103 Murah Call. Somantri 087778355373
 

More from JMAC Supply

Bosch ALTV244UL Data Sheet
Bosch ALTV244UL Data SheetBosch ALTV244UL Data Sheet
Bosch ALTV244UL Data Sheet
JMAC Supply
 
Bosch AL1002WAL Data Sheet
Bosch AL1002WAL Data SheetBosch AL1002WAL Data Sheet
Bosch AL1002WAL Data Sheet
JMAC Supply
 
Bosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data SheetBosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data Sheet
JMAC Supply
 
Bosch AI1 Data Sheet
Bosch AI1 Data SheetBosch AI1 Data Sheet
Bosch AI1 Data Sheet
JMAC Supply
 
Bosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data SheetBosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data Sheet
JMAC Supply
 
Bosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data SheetBosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data Sheet
JMAC Supply
 
Bosch AE774 Data Sheet
Bosch AE774 Data SheetBosch AE774 Data Sheet
Bosch AE774 Data Sheet
JMAC Supply
 
Bosch AE203R Data Sheet
Bosch AE203R Data SheetBosch AE203R Data Sheet
Bosch AE203R Data Sheet
JMAC Supply
 
Bosch AE101 Data Sheet
Bosch AE101 Data SheetBosch AE101 Data Sheet
Bosch AE101 Data Sheet
JMAC Supply
 
Bosch AE4 Data Sheet
Bosch AE4 Data SheetBosch AE4 Data Sheet
Bosch AE4 Data Sheet
JMAC Supply
 
Bosch AE1 Data Sheet
Bosch AE1 Data SheetBosch AE1 Data Sheet
Bosch AE1 Data Sheet
JMAC Supply
 
Bosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data SheetBosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data Sheet
JMAC Supply
 
Bosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data SheetBosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data Sheet
JMAC Supply
 
Bosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data SheetBosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data Sheet
JMAC Supply
 
Bosch 9208B Data Sheet
Bosch 9208B Data SheetBosch 9208B Data Sheet
Bosch 9208B Data Sheet
JMAC Supply
 
Bosch 7110XC Data Sheet
Bosch 7110XC Data SheetBosch 7110XC Data Sheet
Bosch 7110XC Data Sheet
JMAC Supply
 
Samsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data SheetSamsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data Sheet
JMAC Supply
 
Samsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data SheetSamsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data Sheet
JMAC Supply
 
Samsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data SheetSamsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data Sheet
JMAC Supply
 
Samsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data SheetSamsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data Sheet
JMAC Supply
 

More from JMAC Supply (20)

Bosch ALTV244UL Data Sheet
Bosch ALTV244UL Data SheetBosch ALTV244UL Data Sheet
Bosch ALTV244UL Data Sheet
 
Bosch AL1002WAL Data Sheet
Bosch AL1002WAL Data SheetBosch AL1002WAL Data Sheet
Bosch AL1002WAL Data Sheet
 
Bosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data SheetBosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data Sheet
 
Bosch AI1 Data Sheet
Bosch AI1 Data SheetBosch AI1 Data Sheet
Bosch AI1 Data Sheet
 
Bosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data SheetBosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data Sheet
 
Bosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data SheetBosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data Sheet
 
Bosch AE774 Data Sheet
Bosch AE774 Data SheetBosch AE774 Data Sheet
Bosch AE774 Data Sheet
 
Bosch AE203R Data Sheet
Bosch AE203R Data SheetBosch AE203R Data Sheet
Bosch AE203R Data Sheet
 
Bosch AE101 Data Sheet
Bosch AE101 Data SheetBosch AE101 Data Sheet
Bosch AE101 Data Sheet
 
Bosch AE4 Data Sheet
Bosch AE4 Data SheetBosch AE4 Data Sheet
Bosch AE4 Data Sheet
 
Bosch AE1 Data Sheet
Bosch AE1 Data SheetBosch AE1 Data Sheet
Bosch AE1 Data Sheet
 
Bosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data SheetBosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data Sheet
 
Bosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data SheetBosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data Sheet
 
Bosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data SheetBosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data Sheet
 
Bosch 9208B Data Sheet
Bosch 9208B Data SheetBosch 9208B Data Sheet
Bosch 9208B Data Sheet
 
Bosch 7110XC Data Sheet
Bosch 7110XC Data SheetBosch 7110XC Data Sheet
Bosch 7110XC Data Sheet
 
Samsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data SheetSamsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data Sheet
 
Samsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data SheetSamsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data Sheet
 
Samsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data SheetSamsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data Sheet
 
Samsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data SheetSamsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data Sheet
 

Recently uploaded

Accelerate your Kubernetes clusters with Varnish Caching
Accelerate your Kubernetes clusters with Varnish CachingAccelerate your Kubernetes clusters with Varnish Caching
Accelerate your Kubernetes clusters with Varnish Caching
Thijs Feryn
 
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdfSAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
Peter Spielvogel
 
Assure Contact Center Experiences for Your Customers With ThousandEyes
Assure Contact Center Experiences for Your Customers With ThousandEyesAssure Contact Center Experiences for Your Customers With ThousandEyes
Assure Contact Center Experiences for Your Customers With ThousandEyes
ThousandEyes
 
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
UiPathCommunity
 
Welocme to ViralQR, your best QR code generator.
Welocme to ViralQR, your best QR code generator.Welocme to ViralQR, your best QR code generator.
Welocme to ViralQR, your best QR code generator.
ViralQR
 
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdfFIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
FIDO Alliance
 
PCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase TeamPCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase Team
ControlCase
 
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
Ramesh Iyer
 
Transcript: Selling digital books in 2024: Insights from industry leaders - T...
Transcript: Selling digital books in 2024: Insights from industry leaders - T...Transcript: Selling digital books in 2024: Insights from industry leaders - T...
Transcript: Selling digital books in 2024: Insights from industry leaders - T...
BookNet Canada
 
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
UiPathCommunity
 
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 previewState of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
Prayukth K V
 
Key Trends Shaping the Future of Infrastructure.pdf
Key Trends Shaping the Future of Infrastructure.pdfKey Trends Shaping the Future of Infrastructure.pdf
Key Trends Shaping the Future of Infrastructure.pdf
Cheryl Hung
 
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdfFIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
FIDO Alliance
 
Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........
Alison B. Lowndes
 
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptx
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptxSecstrike : Reverse Engineering & Pwnable tools for CTF.pptx
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptx
nkrafacyberclub
 
Assuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyesAssuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyes
ThousandEyes
 
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
Product School
 
Introduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - CybersecurityIntroduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - Cybersecurity
mikeeftimakis1
 
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
Albert Hoitingh
 
Essentials of Automations: Optimizing FME Workflows with Parameters
Essentials of Automations: Optimizing FME Workflows with ParametersEssentials of Automations: Optimizing FME Workflows with Parameters
Essentials of Automations: Optimizing FME Workflows with Parameters
Safe Software
 

Recently uploaded (20)

Accelerate your Kubernetes clusters with Varnish Caching
Accelerate your Kubernetes clusters with Varnish CachingAccelerate your Kubernetes clusters with Varnish Caching
Accelerate your Kubernetes clusters with Varnish Caching
 
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdfSAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
SAP Sapphire 2024 - ASUG301 building better apps with SAP Fiori.pdf
 
Assure Contact Center Experiences for Your Customers With ThousandEyes
Assure Contact Center Experiences for Your Customers With ThousandEyesAssure Contact Center Experiences for Your Customers With ThousandEyes
Assure Contact Center Experiences for Your Customers With ThousandEyes
 
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
Le nuove frontiere dell'AI nell'RPA con UiPath Autopilot™
 
Welocme to ViralQR, your best QR code generator.
Welocme to ViralQR, your best QR code generator.Welocme to ViralQR, your best QR code generator.
Welocme to ViralQR, your best QR code generator.
 
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdfFIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
FIDO Alliance Osaka Seminar: FIDO Security Aspects.pdf
 
PCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase TeamPCI PIN Basics Webinar from the Controlcase Team
PCI PIN Basics Webinar from the Controlcase Team
 
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
Builder.ai Founder Sachin Dev Duggal's Strategic Approach to Create an Innova...
 
Transcript: Selling digital books in 2024: Insights from industry leaders - T...
Transcript: Selling digital books in 2024: Insights from industry leaders - T...Transcript: Selling digital books in 2024: Insights from industry leaders - T...
Transcript: Selling digital books in 2024: Insights from industry leaders - T...
 
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...
 
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 previewState of ICS and IoT Cyber Threat Landscape Report 2024 preview
State of ICS and IoT Cyber Threat Landscape Report 2024 preview
 
Key Trends Shaping the Future of Infrastructure.pdf
Key Trends Shaping the Future of Infrastructure.pdfKey Trends Shaping the Future of Infrastructure.pdf
Key Trends Shaping the Future of Infrastructure.pdf
 
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdfFIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
FIDO Alliance Osaka Seminar: Passkeys at Amazon.pdf
 
Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........Bits & Pixels using AI for Good.........
Bits & Pixels using AI for Good.........
 
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptx
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptxSecstrike : Reverse Engineering & Pwnable tools for CTF.pptx
Secstrike : Reverse Engineering & Pwnable tools for CTF.pptx
 
Assuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyesAssuring Contact Center Experiences for Your Customers With ThousandEyes
Assuring Contact Center Experiences for Your Customers With ThousandEyes
 
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
De-mystifying Zero to One: Design Informed Techniques for Greenfield Innovati...
 
Introduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - CybersecurityIntroduction to CHERI technology - Cybersecurity
Introduction to CHERI technology - Cybersecurity
 
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024
 
Essentials of Automations: Optimizing FME Workflows with Parameters
Essentials of Automations: Optimizing FME Workflows with ParametersEssentials of Automations: Optimizing FME Workflows with Parameters
Essentials of Automations: Optimizing FME Workflows with Parameters
 

Takex PB-200HF-KH Instruction Manual

  • 1.
  • 2. 1) DO'S AND DON'T'S 2) Protection distance 2 CAUTIONS ON INSTALLATION ・Do not install the unit on places where it may be splashed by dirty water or direct ocean spray. ・Do not install the unit on unsteady surfaces. ・Do not install the unit at places where it may be interrupted by obstacles such as trees. ・Avoid strong light from the sun, automobile headlights etc. shining on transmitter and receiver directly. (Avoid light within ±2°degrees of optical axis.) 1) Basic connection The equipment must be powered from an LPS in accordance with EN60950-1 : 2001 2) When two or more sensors are connected to the same line. 3) When two or more sensors are connected to separate lines. 4) When two sensors are stacked and connected to the same line. TR RE Power (DC12V) Power (DC12V) Power (DC12V) Power (DC12V) Alarm signal Alarm signal 1 Alarm signal 2 Alarm signal (N.C.) Alarm signal (N.C.) (Control panel) (Control panel) (Control panel) (Control panel) } } Wiring } } } } } } } (CH3) (CH1) TR RE TR RE TR RE TRRE TRRE B Up to 50m Up to 100m Up to 200m 1.2m (A=50m) 2.4m (A=100m) 5.0m (A=200m) PB- 50HF-KH PB-100HF-KH PB-200HF-KH AModel B Protection distance A ② ①② ①② ①② ① ② ③ ④ ① ② ③ ④①② ①②③④ ①②③④ ①②③④① ② ③ ④① ② ①② ①②①②③④
  • 3. Power(DC12V) Alarm signal Environmental signal (N.O. N.C. selectable) External control switch (Control panel) } } } ○+ ○− 5) When environmental output and remote alarm memory are used. 6) Wiring distance Max. wiring distance when two or more sets are connected is the above value divided by the number of sets. The signal line can be wired to a distance of up to 6,600ft. (2,000m) with AWG 20 (dia.0.8mm) telephone wire. Note : 1) 2) TR RE wire size PB-50HF-KH PB-100HF-KH PB-200HF-KH 12V DC 24V DC 12V DC 24V DC 12V DC 24V DC Model Power voltage Terminal arrangement Mounting ●Install the unit to a beam tower.  Some towers could block the beam within its case when the mirror is turned by ±90° vertically.  Please refer to the instruction manual of the beam tower carefully before use. ●Beam sensor's reflecting mirror can be moved horizontally (±90 degrees) and vertically (±10 degrees) allowing the unit to work in all directions. ±10° ±90° + ① ② ③ ④ ⑨ ⑩ ⑪ ① ② ① ② ① ② ③ ④ ⑨ ⑩ ⑪ − + − [Transmitter] Beam sensor [Receiver] 30V (AC/DC) 0.5A MAX. N.C. or N.O. Alarm N.C. or N.O. 30V (AC/DC) 1A MAX. Environmental Alarm memory Power 12 to 30V DC (non-polarity) Power 12 to 30V DC (non-polarity) 90° ③ AWG20 (Dia.0.8mm) AWG18 (Dia.1.0mm) AWG17 (Dia.1.1mm) AWG16 (Dia.1.25mm) AWG15 (Dia.1.4mm) AWG14 (Dia.1.6mm) 800' (244m) 1250' (381m) 1500' (457m) 1950' (595m) 2500' (750m) 3200' (976m) 5600' (1710m) 8800' (2680m) 10500' (3200m) 13500' (4000m) 17000' (5180m) 22500' (6860m) 660' (200m) 1100' (335m) 1350' (400m) 1750' (534m) 2200' (670m) 2900' (884m) 5100' (1550m) 7900' (2410m) 9600' (2930m) 12000' (3660m) 15500' (4730m) 20000' (6000m) 630' (192m) 1000' (300m) 1200' (366m) 1550' (473m) 1950' (595m) 2550' (777m) 4400' (1340m) 6900' (2100m) 8400' (2560m) 10500' (3200m) 13500' (4000m) 17500' (5340m)
  • 4. ①Look through view finder on either side upper transmitter optical unit and move until receiver unit is visible. ②Repeat the procedure for lower optical unit and then repeat on receiver. ●Procedure detail ●Function options ③nAttach the shading plates to the lower optics of both transmitter and receiver. ④Turn the receiver beep switch "ON". ⑤Adjust the optics with the adjustment screws until highest tone is reached. (Note : There will be no sound if the sensitivity LED is lit.) ⑥Check output voltage by monitor output. A precise alignment can be accomplished by using a digital volt meter. ⑦Reverse the procedure, i.e. attach shading plates to upper optics of transmitter and receiver and repeat adjustment. ⑧After adjustment, replace the shading plates in the storage areas of transmitter and receiver. View finder Adjustment dial Horizontal angle adjustment screw Vertical angle adjustment screw Location Transmitter and receiver Transmitter only Receiver only Beam frequency Beam power Beep switch Alarm memory Environmental output Response time Alarm output Functions Function switches □1CH □2CH □3CH □4CH □H □L □N.O.   □N.C. □0.05sec. □0.3sec. □0.7sec. □Others □ON   □OFF □N.O.  □N.C. □Timer  □Remote Voltage reading 2.7V or more 2.0V to 2.7V 2.0V or less Sensitivity Best Good Poor, re-adjust Digital volt meter Sensitivity LED Beep switch Monitor jack 3SET-UP OF FUNCTIONS AND BEAM ALIGNMENT 1) Supply power with covers off. 2) Set function options according to the right table. 3) Adjust optical angle. 1) Alarm LED only. 2) Alarm LED and beep tone. (Walk test mode) Set the beep switch to "ON", then a beep tone will be issued upon beam blockage for five minutes after the Auto gain is locked. After installation and beam alignment, check operation by walk test. Two methods may be used. Lights Lights Lights 1)Check by alarm LED RE RETR TR 2)Check by walk test mode Lights Beep 4OPERATION CHECK Rock spacer (Put "A" side in) Place the covers on the beam line before insert the lock spacer so as to get the same beam strength as the covers are attached. ⑨After beam alignment, place the covers on the beam line. Then insert a lock spacer to the micro switch part for gain lock on the receiver unit. ⑩5sec. after, sensitivity margin will be automatically set and gain lock will be completed after beep sound is heard once. If the beep sound is heard in an intermittent way, sensitivity is not good. In this case, remove the lock spacer and adjust beam alignment again. (Please refer to 5.5 Auto-gain lock function.) TX RX ④
  • 5. The combination of 1CH and 3CH or 2CH and 4CH (do not use adjacent channels) are recommended to avoid crosstalk between units which are stacked, in-line, or other configurations which have the potential of spillover transmission from one beam to another. Set the frequency level as illustrated. Make sure both transmitter and receiver of pair are set to the same channel. The use of voltmeter for alignment is recommended to ensure highest level of stability. For stacked protection, make sure that beam sensors to be installed are the same model with the same beam power selection. Consult with TAKEX distributor or TAKEX regional office about the frequency selection for installations not mentioned in this instruction manual. Inappropreate choice of frequency may cause malfunction. 4. Four channel frequency selection 1CH 2CH 3CH 4CH Note : 1) 1. Alarm memory function (Receiver) The alarm memory LED indicates which sensor has triggered when two or more sensors are placed on a zone. An audible tone in addition is optional. Reset can be timer or remote. 2. Alarm output N.C. or N.O. signal output is selectable. If alarm memory function is not used, set the memory selector to "Remote" and leave receiver terminal ⑪ unconnected. 3. Beam power selection (Transmitter) Up to 83' (25m) Up to 248' (75m) Up to 495' (150m) Connect / disconnect terminal ⑪ and ○+ terminal (① or ②) 1) Auto-reset 2)Manual60min.(re-trigger) 5min. Alarm output Connect terminal ⑪ and ○+ terminal (① or ②) Memory LED 5min. 55min.(flickering) N.C.N.O. Alarm output selectable switch (Initial setting:N.C.) 〔Alarm memory selectable switch〕 ← → Auto-reset Manual Alarm memory selectable switch(Initial setting:Manual) 〔Alarm output selectable switch〕 ← → Alarm output Alarm memory input Memory LED Short ShortShort Open Open Beep sound at (Beep switch ON) Lights 5FUNCTIONS DESCRIPTION Note : 1) Line protection 1CH TR 1CH RE 3CH TR 3CH TR 3CH RE 4CH TR 4CH RE 3CH RE 1CH TR 1CH RE 1CH RE 3CH RE 2CH RE 4CH RE 2CH RE 4CH RE 1CH RE 3CH RE 2CH TR 2CH RE 1CH TR 3CH TR 1CH RE 1CH TR 1CH RE 1CH TR 1CH TR 1CH TR 2CH TR 3CH TR 4CH TR 2CH TR 1CH TR 4CH TR 3CH TR 3CH TR 1CH TR 3CH TR 1CH RE 1CH RE 3CH RE 3CH RE 1CH RE 3CH RE 3CH TR 3CH RE 2) 2-stacked protection 3) Line and 2-stacked protection 4) Perimeter protection 5) Perimeter double stacked protection L H PB- 50HF-KH PB-100HF-KH PB-200HF-KH Above 83' (25m) Up to 165' (50m) Above 248' (75m) Up to 330' (100m) Above 495' (150m) Up to 660' (200m) ⑤ 2) 3)
  • 6. OK not good Run at full speed Walk with quick steps Walking Response time: 0.05 sec. Response time: 0.3 sec. Response time: 0.7 sec. Response time adjustment (Beam sensor) (0.3) 0.7(sec.) 0.05(sec.) 5. Auto-gain lock function 6. Tone indicator 7. Response time 8. Environmental check 2) A "beep" tone is issued from the receiver approximately five seconds after the lock spacer is put into position. This tone indicates the Auto-gain has been set. Refer to the chart below. 1) The auto-gain lock serves to standardize the responsiveness and tolerance level of the units regardless of varying distance in an installation. Less than protection distance Max. Protection distance Tone One pulse (beep) Continuous tone (20 seconds) Indicates Result The environmental signal is initiated if the beam reception level is reduced by poor weather conditions (dense fog or torrential rain etc.). N.C. or N.O. signal output is selectable. (Contact capacity 30V (AC/DC) 1A MAX.) Adjust response time as follows. The unit does not detect the passing object faster than the response time set. If the response time is set extremely long, the unit may be unable to detect human pattern. Adjust a little longer response time in a site where large passing objects such as birds, newspapers or falling leaves may move. Beam alignment ON ON ON N.O. N.C. Alignment tone switchTest / Signal Description RemedyCause Other condition Auto-gain lock Walk test Alarm memory Reception strength monitored. Tone pitch increases as reception improves. Note : No tone is given if sensitivity attenuation LED is lit or if the lock spacer is attached. 1. Remove obstructions and replace cover. Check beep tone. 2. Check beam power setting at transmitter with cover off and re-adjust beam alignment. 1. Beam is interrupted once cover is replaced. 2. Beam is misaligned and sensitivity attenuation LED lights. Optimal sensitivity has been set. Optimal sensitivity cannot be set. Short tone indicates lock is set. Continuous tone (20sec.) indicates readjustment. Lock spacer detached About 5sec. after the lock spacer is attached. For approx. 5min. after gain is locked. Set to manual memory Tone is linked to alarm LED. Both trip simultaneously. "Beep" is indicated if alarm condition occurs. Environmental output selector (Initial setting:N.C.) A tone is generated regardless of whether "beep" (alignment tone) switch is set to ON or OFF. The auto-gain setting is locked in even if power is disrupted. If the lock spacer is detached while power is supplied or if power is discontinued , the auto-gain automatically resets to maximum sensitivity. Note : 1) 2) 3) ⑥
  • 7. 6TROUBLESHOOTING 7 SPECIFICATIONS Symptom Possible cause Remedy Transmitter LED does not light 1. No power supply 1. No power supply 2. Bad wiring connection, or broken wire, short 2. Check wire 2. Check wire 1. Turn on the power 1. Turn on the power 4. 4 photoelectric beams are not broken simultaneously 3. Photoelectric beam is reflected on another object and sent into the receiver 2. Bad wiring connection 4. Interrupt 4 beams simultaneously 3. Remove the reflecting object or change the place for installation Receiver LED continues to light (An alarm does not stop) Receiver LED does not light when the beam is broken 3. Optics of units are soiled 4. Frequency channel setting on transmitter does not match with that on receiver 2. Shading object between transmitter and receiver 1. Alignment is off 4. Readjust to be the same channel 3. Clean the optics with a soft cloth 2. Remove the shading object 1. Check and adjust again 8. Small animals may pass through the 4 photoelectric beams 9. Installation site or installation height is not appropriate 7. Improper alignment 6. Optics of units are soiled 5. Unstable installation of unit 4. A large electric notise source such as power machine, is located nearby transmitter and receiver 3. Shading object between transmitter and receiver 2. Change of supply voltage 1. Bad wiring connection 8. Change installation site or environments 9. Re-adjust the installation site or height 7. Check and re-adjust 6. Clean the optics with soft cloth 5. Stabilize 4. Change the place for installation 3. Remove the shading object 2. Stabilize supply voltage 1. Check again Intermittent alarm Photo electric beam sensor PB-50HF-KH 165ft. (50m) or less 1650ft. (500m) (tenfold margin distance) LED (pulsed beam by LED) Double modulation Photoelectric beam 0.05sec. to 0.7sec. (Variable at pot) Dry contact relay output N.O. / N.C. Contact action : Interruption time + delay time (approx. 2sec.) Contact capacity : 30V (AC/DC) 1A Dry contact relay output N.O. / N.C. Contact capacity : 30V (AC/DC) 0.5A 12 to 30V DC When alarmed 60mA or less ・Transmitter : 15mA or less ・Receiver : 45mA or less When adjusted 95mA or less Alignment tone switch, Attenuation LED, Monitor jack, Alarm memory indication, Modulation frequency selectable (4stage), Environmental check, Automatic gain control (AGC) circuit, Transmitter 10.6oz (300g) Receiver 14.1oz (400g) ABS resin Type Model Protection distance Max. arrival distance Infrared beam Detection system Response time Alarm signal Environmental signal Supply voltage Power consumption Functions Weight Appearance PB-100HF-KH 330ft. (100m) or less PB-200HF-KH 660ft. (200m) or less 3300ft. (1000m) (tenfold margin distance) 6600ft. (2000m) (tenfold margin distance) When alarmed 70mA or less ・Transmitter : 25mA or less ・Receiver : 45mA or less When adjusted 105mA or less When alarmed 85mA or less ・Transmitter : 40mA or less ・Receiver : 45mA or less When adjusted 120mA or less ⑦
  • 8. No.05-526 1110 ⑧ In Japan Takex America Inc. Unit 16/35 Garden Road, Clayton, 3168 Victoria, Australia Tel : 03-9546-0533 Fax : 03-9547-9450 Takenaka Engineering Co., Ltd. 83-1, Gojo-sotokan, Higashino, Yamashina-ku, Kyoto 607-8156, Japan Tel : 81-75-501-6651 Fax : 81-75-593-3816 http : // www. takex-eng. co. jp / Takex America Inc. 230E, Caribbean Drive Sunnyvale, CA 94086, U.S.A. Tel : 408-747-0100 Fax : 408-734-1100 http : // www. takex. com Takex Europe Ltd. Takex House, Aviary Court, Wade Road, Basingstoke, Hampshire. RG24 8PE, U.K. Tel : (+44) 01256-475555 Fax : (+44) 01256-466268 http : // www. takexeurope. com In the U.S. In the U.K.In Australia EXTERNAL DIMENSIONS 8 SPECIAL NOTES 9This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio / TV technician for help. WARNING : Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Limited Warranty : TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or failure caused by Acts of God (including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for product repairs made after our Warranty period has expired. MOUNT HOLE 13.78"(350mm) 3.46" (88mm) 2.36"(60mm) 2.83" (72mm) 4-φ0.12" (φ3mm) 5.12"(130mm)