This document provides information on the VDY series of incandescent lighting fixtures from NAMBUK Electric Co. It includes three sections:
1. An overview of the VDY series, which are weatherproof fixtures intended for industrial applications where weather damage is a concern.
2. Technical specifications for the VDY fixtures, including materials, finishes, certifications, and photometric data.
3. Dimensional drawings and ordering information.
This document provides information on Group II cable glands for use in hazardous areas. It includes details on features, applications, certification options, and a cable gland selection table with specifications for different gland sizes. Certification options include ATEX/IECEx for Zone 1 and Zone 2 areas, as well as cCSAus for North American hazardous locations. The document specifies construction and testing standards and provides ordering information format.
This document provides information on ATEX Zone 22 certified switch-disconnectors and isolators from Craig & Derricott for use in explosive dust atmospheres. It lists product ratings from 20A to 63A, certifications that comply with relevant standards, technical specifications including short circuit ratings, and enclosure size dimensions from A to D. Applications include grain mills, powder coating plants, chemicals handling, and other industries where combustible dust may be present for short periods.
The PrimeTest 350 is an advanced portable electrical safety tester derived from the PrimeTest 300. It features Bluetooth and USB connectivity for wireless data transfer. Batteries can be charged via port while still in the unit. It is lightweight at under 1kg and small, measuring 26cm x 10cm. The tester complies with updated safety standards and can perform various essential electrical tests quickly and efficiently.
Hazardous Area Isolators
ATEX Isolators - Zone 22 Category 3D Isolators
Craig & Derricott ATEX certified isolators and switch disconnectors for hazardous area Group II, Zone 22, Cat 3D Non-Conductive Dusts - typical installation areas include grain mills, textiles, cargo handling, powder coating plant, chemicals, woodworking and waste processing.
From July 2006 the onus was placed upon companies to ensure that all electrical equipment within their site organisation is suitable for the environment in which it is being used - this was aimed particularly at hazardous areas where there may be a possibility of a combustible atmosphere being present, even for short periods i.e. less than 10 hours/year.
People normally think of such atmospheres as being gases, mists or vapours - however there are various industries where a conductive or non-conductive dust mixed with air in the right proportion can become explosive.
There are different degrees of protection against explosive dusts and hazardous area Zone 22 is defined as : - "a place in which an explosive atmosphere, in the form of a cloud of combustible dust in air, is not likely to occur in normal operation but, if it does occur, will persist for a short period only".
ATEX Directive 94/9/EC sets out the route electrical equipment manufacturers must take to get their products certified for use in hazardous areas.
ATEX Certified Electrical Equipment for Hazardous Areas
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
This technical data sheet provides information on i-switch ATEX Certified Zone 1 Switch Disconnectors for use in hazardous environments. It lists the electrical ratings and certifications for disconnectors ranging from 16A to 250A. Dimensions and standard configurations are provided for each enclosure type, along with example catalogue numbers. Additional configurations can be custom ordered.
This document provides information on various types of brass cable glands and fittings produced by The Pearl International, including:
- Type A1/A2 cable glands that provide IP66 protection and single displacement sealing for unarmored cables
- BW cable glands for armored cables that provide mechanical retention and electrical continuity via a three-part armor lock
- Double compression glands that provide IP66 protection and seal both the inner and outer sheaths of steel wire armored cables
- Specifications, materials, sizes, temperature ratings, and accessories are provided for each type.
Techfluid manufactures our own bonded rubber Mud, Cement and Tensioner hoses with spirally laid high tensile steel cable reinforcement and one-piece bonded in end couplings. The hoses are mandrel built in continuous lengths up to 70 metres and vulcanised to form a fully bonded hose offering high integrity and excellent flexibility. Our range covers pressures up to 15,000psi in sizes up to 16”.
This document provides information on Group II cable glands for use in hazardous areas. It includes details on features, applications, certification options, and a cable gland selection table with specifications for different gland sizes. Certification options include ATEX/IECEx for Zone 1 and Zone 2 areas, as well as cCSAus for North American hazardous locations. The document specifies construction and testing standards and provides ordering information format.
This document provides information on ATEX Zone 22 certified switch-disconnectors and isolators from Craig & Derricott for use in explosive dust atmospheres. It lists product ratings from 20A to 63A, certifications that comply with relevant standards, technical specifications including short circuit ratings, and enclosure size dimensions from A to D. Applications include grain mills, powder coating plants, chemicals handling, and other industries where combustible dust may be present for short periods.
The PrimeTest 350 is an advanced portable electrical safety tester derived from the PrimeTest 300. It features Bluetooth and USB connectivity for wireless data transfer. Batteries can be charged via port while still in the unit. It is lightweight at under 1kg and small, measuring 26cm x 10cm. The tester complies with updated safety standards and can perform various essential electrical tests quickly and efficiently.
Hazardous Area Isolators
ATEX Isolators - Zone 22 Category 3D Isolators
Craig & Derricott ATEX certified isolators and switch disconnectors for hazardous area Group II, Zone 22, Cat 3D Non-Conductive Dusts - typical installation areas include grain mills, textiles, cargo handling, powder coating plant, chemicals, woodworking and waste processing.
From July 2006 the onus was placed upon companies to ensure that all electrical equipment within their site organisation is suitable for the environment in which it is being used - this was aimed particularly at hazardous areas where there may be a possibility of a combustible atmosphere being present, even for short periods i.e. less than 10 hours/year.
People normally think of such atmospheres as being gases, mists or vapours - however there are various industries where a conductive or non-conductive dust mixed with air in the right proportion can become explosive.
There are different degrees of protection against explosive dusts and hazardous area Zone 22 is defined as : - "a place in which an explosive atmosphere, in the form of a cloud of combustible dust in air, is not likely to occur in normal operation but, if it does occur, will persist for a short period only".
ATEX Directive 94/9/EC sets out the route electrical equipment manufacturers must take to get their products certified for use in hazardous areas.
ATEX Certified Electrical Equipment for Hazardous Areas
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
This technical data sheet provides information on i-switch ATEX Certified Zone 1 Switch Disconnectors for use in hazardous environments. It lists the electrical ratings and certifications for disconnectors ranging from 16A to 250A. Dimensions and standard configurations are provided for each enclosure type, along with example catalogue numbers. Additional configurations can be custom ordered.
This document provides information on various types of brass cable glands and fittings produced by The Pearl International, including:
- Type A1/A2 cable glands that provide IP66 protection and single displacement sealing for unarmored cables
- BW cable glands for armored cables that provide mechanical retention and electrical continuity via a three-part armor lock
- Double compression glands that provide IP66 protection and seal both the inner and outer sheaths of steel wire armored cables
- Specifications, materials, sizes, temperature ratings, and accessories are provided for each type.
Techfluid manufactures our own bonded rubber Mud, Cement and Tensioner hoses with spirally laid high tensile steel cable reinforcement and one-piece bonded in end couplings. The hoses are mandrel built in continuous lengths up to 70 metres and vulcanised to form a fully bonded hose offering high integrity and excellent flexibility. Our range covers pressures up to 15,000psi in sizes up to 16”.
This document provides information on sheet steel light fittings series 6014 and 6414, including:
- They are available as pendant, wall, and recessed light fittings in 1 to 4 lamp versions for zones 1, 2, 21, and 22.
- It provides technical specifications for electrical data, ambient conditions, materials, and assembly for both series.
- Selection tables list available models with lamp wattages, widths, order numbers, and weights.
This document provides information on sheet steel light fittings series 6014 and 6414, including:
- They are available as pendant, wall, and recessed light fittings in 1 to 4 lamp versions for zones 1, 2, 21, and 22.
- It provides technical specifications for electrical data, ambient conditions, materials, and assembly for both series.
- The selection table lists available models with lamp wattages, widths, order numbers, and weights.
This document provides information on cable glands certified for use in hazardous areas. It includes:
1) An overview of the 501/421 cable gland which provides a seal for non-armored cables and is suitable for Zone 1, Zone 2, and Division 2 hazardous areas.
2) A cable gland selection table that lists various gland sizes, entry thread sizes, cable acceptance details, and dimensions.
3) Technical data on the gland's ATEX, IECEx, and cCSAus certification for use in Zone 1, Zone 2, Zone 21, Zone 22, and Division 2 hazardous locations. It also lists construction standards, ingress protection, operating temperature range, and deluge protection.
This document provides information on the DAH series heavy duty metal oxide surge arresters from Bowthorpe EMP. The key points are:
1) The DAH arresters use an integrated design with silicone housing that provides moisture protection and proven performance.
2) They are tested according to IEEE standards and provide reliable overvoltage protection for distribution assets from lightning and switching surges.
3) The arresters are available in various ratings from 3.5kV to 36kV and incorporate robust ground lead disconnects and mounting accessories.
GUROFLEX MV is a two-component cold-pour insulating compound that cures to a soft, rubbery solid without the need for heating. It has excellent electrical characteristics and can be used to insulate medium voltage electrical equipment up to 36kV. Unlike traditional hot-pour compounds, GUROFLEX MV does not require special safety measures during handling or disposal due to its non-hazardous properties. Its principal use is filling cable termination boxes and busbar enclosures for transformers, switchgear, and motors. GUROFLEX MV has undergone extensive testing to international standards and provides a safe and effective solution for insulating complex phase metalwork with reduced clearances.
The document provides information on the Series 6521/4 explosion protected floodlight for use in explosive gas atmospheres and areas with combustible dust. It describes the different versions and sizes available, including enclosure material options, lamp capacities and temperature classes. Tables provide ordering information, technical specifications, certifications and accessories. The floodlight is available in three sizes to match power needs and can be fitted with different lamp types and reflectors.
The two-piece plastic two bolt cleat is suitable for securing cables with diameters between 50-94mm. It is manufactured from black nylon 66 that is resistant to corrosion from oils and chemicals as well as UV light and weather. The cleat has a two-piece, two fixing design and can be double stacked on common fixings while operating in temperatures from -25°C to +85°C.
This document describes the 3MTM Cold Shrink Joint, SC145-II/SS145-II, which is used for making shielded power cable joints rated up to 145 kV. It provides key information on the product, including its features, applications, specifications, test results, installation process, storage requirements, and contact information. The joint uses cold shrink technology requiring no special tools or heat for installation. It is designed for in-line and crossbond/shield break jointing of various cable shield types with copper or aluminum conductors.
The ML35 LED industrial light series by GLEDsolutions offers high lumen output and efficacy for industrial applications. It is available in wattages from 80W to 150W with lumen outputs up to 15,500 lm and maximum efficacy up to 115 lm/W. It features an IP68 waterproof rating, 5 year warranty, and multiple mounting options for surface, chain, or yoke mounting. Thermal management allows effective heat dissipation to keep the LEDs running cooler and longer.
This document provides a summary of 3M's 8440 Series silicone rubber cold shrink connector insulators. It describes the product as open-ended, tubular sleeves that are factory expanded and shrink to form a tight seal when installed. The document lists the product's key features such as being simple to install without tools or heat, resisting moisture and chemicals, and having an operating temperature range of -55°C to 260°C. It also provides application examples, specifications, test data on performance properties, and ordering information.
Our pros know safety equipment and supplies. This document provides an overview of various safety products organized by category including eye protection, respirators, ear protection, sunscreen, gloves, vests and more. For each product, the description highlights key features and benefits. A variety of options are presented with details on sizing, materials, certifications and pricing to suit different applications and budgets.
Dual Wall Flame Retarded Heat Shrink Tubing
Military Grade Heat Shrink : MIL-DTL 23053/4
Underwriters Lab : UL 224
CSA : 600V, 125 Degrees Celsius
Heat Shrink Tubings - Insulate, Protect & Identify
SPDW heat shrink is ideal for sealing connector to cable transitions and similar moisture proofing applications with adhesive lined tubing.
SPDW is approved to MIL-DTL 23053/4 and UL 224.
Shrinktek Dual Wall Flame Retarded Heat Shrink Tubing
Thorne & Derrick are the largest UK distributor of heat shrink tubings and sleevings including 3M, Panduit, Hellermann Tyton, DSG Canusa, Shrinktek and Thomas & Betts.
Stock lines include thin, medium and thick wall adhesive lined heat shrink sleeves and moulded shapes (heat shrink cable caps, cable breakouts and cable boots) - insulate, seal, protect with heat shrinkable tubing.
This document provides information on explosion-protected floodlight models in the Series 6121. It includes specifications for sizes 2 and 3 IIC models and size 2 IIB models. The lights can be used with various halogen, metal halide, and sodium vapor lamps up to 1000W. They have an aluminum housing, adjustable mounting, and IP66/67 protection. Operating temperatures range from -20°C to +40°C or +55°C. Accessories like lamps and spare parts are also detailed.
This document provides product information on the Predator floodlight by Holophane, including:
- It offers versatility, efficiency, and performance for a variety of lighting needs.
- It can generate wide, narrow, and spot distributions and withstand harsh environments, allowing use in diverse applications.
- Flexibility is maximized with its 360° swivel mounting yoke and quick disconnect removable door for easy maintenance.
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Helashrink heatshrink boots and moulded shapes in conjunction with specialist heatshrink tubing make it easy to fabricate complete jacketed wire and cable harnessing and interconnection systems.
Hellermann Tyton Helashrink heatshrink boots (straight and right-angled) and moulded shapes are available for the complete range of electrical and electronic harnessing applications. Heat shrink boots and shapes can be sealed with special adhesives and encapsulants to ensure the proper degree of mechanical support, strain relief and environmental protection. Encapsulating the complete harnessing and interconnection system to the desired configuration is easily and neatly accomplished with minimum weight and bulk using Hellermann Tyton Helashrink heat shrink components.
Hellermann Tyton Heat Shrink Moulded Shapes & Boots - Overview....
Hellermann Tyton Helashrink heat shrinkable shapes, end caps and cable break-out boots with and without inner adhesive. Hellermannn Tyton heat shrink backshells, 2-way outlet shapes, 3-way outlet shapes, 4-way outlet shapes, 5-way outlet shapes up to 6-way outlet shapes. Hellermann Tyton heat shrink right angle boot 90°, 45°C angle, T-shapes, Y-outlet, VG-style shapes. Heat shrink cable end caps for low voltage applications, two components epoxy adhesive and hot melt tape.
The document is a 4-page datasheet describing 3M's Cold Shrink EPDM Tubes Connector Insulators. It provides information on the product description, features, applications, specifications, and installation techniques. The tubes are open-ended rubber sleeves that are factory-expanded and shrink to form a waterproof seal over cable connections when installed. They can be used for insulation of cable splices and terminations rated up to 1000 volts on cables from 6mm2 to 500mm2. The datasheet includes specifications on sizes available, physical properties of the material, electrical properties, and testing procedures to ensure waterproofing and durability.
The document is a 4-page datasheet describing 3M's Cold Shrink EPDM Tubes Connector Insulators. It provides information on the product description, features, applications, specifications, and installation techniques. The tubes are open-ended rubber sleeves that are factory-expanded and shrink to form a waterproof seal around cable connections when installed. They can be used for insulation of cable splices and terminations rated up to 1000 volts on cables from 6mm2 to 500mm2. The datasheet includes specifications on sizes available, physical properties of the material, and test data demonstrating the product's moisture resistance and electrical performance.
This document provides information on 3M's 8440 Series Silicone Rubber Cold Shrink Lug and Connector Insulators, including:
- Details sizes and application ranges for insulating cable lugs and connectors from 6.86mm to 24.13mm.
- Features like simple installation without tools, maintaining a tight seal over time in various conditions.
- Results from testing the insulators' performance in humidity, UV exposure, thermal shock, fluid resistance and more.
- Physical and electrical properties of the high stretch silicone rubber material.
- Installation and maintenance instructions.
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Applications - Ex Pendant Light Fittings For Hazardous Area Gas & Dust Environments
This document provides information on TMC Co., Ltd's halogen free and mud resistant offshore cables that are compliant with various industry standards. It includes details on cable constructions for high voltage power cables with voltages ranging from 3.6/6kV to 8.7/15kV. Tables provide specifications for different cable types and sizes, listing information like conductor size, insulation thickness, armor wire diameter, nominal diameter and weight. The document also outlines the company's history and certifications obtained for its marine cable products.
Walsall Equipment is a British manufacturer of electrical equipment for hazardous, wet, and dusty environments. It has offices worldwide including Europe, Asia, Africa, and Australia. The company produces a wide range of ATEX-approved products for zone 1, 2, 21, and 22 applications, including junction boxes, lighting, control stations, and cable management systems. It has a purpose-built manufacturing facility with advanced equipment and invests heavily in new technology and product development.
This document provides information on sheet steel light fittings series 6014 and 6414, including:
- They are available as pendant, wall, and recessed light fittings in 1 to 4 lamp versions for zones 1, 2, 21, and 22.
- It provides technical specifications for electrical data, ambient conditions, materials, and assembly for both series.
- Selection tables list available models with lamp wattages, widths, order numbers, and weights.
This document provides information on sheet steel light fittings series 6014 and 6414, including:
- They are available as pendant, wall, and recessed light fittings in 1 to 4 lamp versions for zones 1, 2, 21, and 22.
- It provides technical specifications for electrical data, ambient conditions, materials, and assembly for both series.
- The selection table lists available models with lamp wattages, widths, order numbers, and weights.
This document provides information on cable glands certified for use in hazardous areas. It includes:
1) An overview of the 501/421 cable gland which provides a seal for non-armored cables and is suitable for Zone 1, Zone 2, and Division 2 hazardous areas.
2) A cable gland selection table that lists various gland sizes, entry thread sizes, cable acceptance details, and dimensions.
3) Technical data on the gland's ATEX, IECEx, and cCSAus certification for use in Zone 1, Zone 2, Zone 21, Zone 22, and Division 2 hazardous locations. It also lists construction standards, ingress protection, operating temperature range, and deluge protection.
This document provides information on the DAH series heavy duty metal oxide surge arresters from Bowthorpe EMP. The key points are:
1) The DAH arresters use an integrated design with silicone housing that provides moisture protection and proven performance.
2) They are tested according to IEEE standards and provide reliable overvoltage protection for distribution assets from lightning and switching surges.
3) The arresters are available in various ratings from 3.5kV to 36kV and incorporate robust ground lead disconnects and mounting accessories.
GUROFLEX MV is a two-component cold-pour insulating compound that cures to a soft, rubbery solid without the need for heating. It has excellent electrical characteristics and can be used to insulate medium voltage electrical equipment up to 36kV. Unlike traditional hot-pour compounds, GUROFLEX MV does not require special safety measures during handling or disposal due to its non-hazardous properties. Its principal use is filling cable termination boxes and busbar enclosures for transformers, switchgear, and motors. GUROFLEX MV has undergone extensive testing to international standards and provides a safe and effective solution for insulating complex phase metalwork with reduced clearances.
The document provides information on the Series 6521/4 explosion protected floodlight for use in explosive gas atmospheres and areas with combustible dust. It describes the different versions and sizes available, including enclosure material options, lamp capacities and temperature classes. Tables provide ordering information, technical specifications, certifications and accessories. The floodlight is available in three sizes to match power needs and can be fitted with different lamp types and reflectors.
The two-piece plastic two bolt cleat is suitable for securing cables with diameters between 50-94mm. It is manufactured from black nylon 66 that is resistant to corrosion from oils and chemicals as well as UV light and weather. The cleat has a two-piece, two fixing design and can be double stacked on common fixings while operating in temperatures from -25°C to +85°C.
This document describes the 3MTM Cold Shrink Joint, SC145-II/SS145-II, which is used for making shielded power cable joints rated up to 145 kV. It provides key information on the product, including its features, applications, specifications, test results, installation process, storage requirements, and contact information. The joint uses cold shrink technology requiring no special tools or heat for installation. It is designed for in-line and crossbond/shield break jointing of various cable shield types with copper or aluminum conductors.
The ML35 LED industrial light series by GLEDsolutions offers high lumen output and efficacy for industrial applications. It is available in wattages from 80W to 150W with lumen outputs up to 15,500 lm and maximum efficacy up to 115 lm/W. It features an IP68 waterproof rating, 5 year warranty, and multiple mounting options for surface, chain, or yoke mounting. Thermal management allows effective heat dissipation to keep the LEDs running cooler and longer.
This document provides a summary of 3M's 8440 Series silicone rubber cold shrink connector insulators. It describes the product as open-ended, tubular sleeves that are factory expanded and shrink to form a tight seal when installed. The document lists the product's key features such as being simple to install without tools or heat, resisting moisture and chemicals, and having an operating temperature range of -55°C to 260°C. It also provides application examples, specifications, test data on performance properties, and ordering information.
Our pros know safety equipment and supplies. This document provides an overview of various safety products organized by category including eye protection, respirators, ear protection, sunscreen, gloves, vests and more. For each product, the description highlights key features and benefits. A variety of options are presented with details on sizing, materials, certifications and pricing to suit different applications and budgets.
Dual Wall Flame Retarded Heat Shrink Tubing
Military Grade Heat Shrink : MIL-DTL 23053/4
Underwriters Lab : UL 224
CSA : 600V, 125 Degrees Celsius
Heat Shrink Tubings - Insulate, Protect & Identify
SPDW heat shrink is ideal for sealing connector to cable transitions and similar moisture proofing applications with adhesive lined tubing.
SPDW is approved to MIL-DTL 23053/4 and UL 224.
Shrinktek Dual Wall Flame Retarded Heat Shrink Tubing
Thorne & Derrick are the largest UK distributor of heat shrink tubings and sleevings including 3M, Panduit, Hellermann Tyton, DSG Canusa, Shrinktek and Thomas & Betts.
Stock lines include thin, medium and thick wall adhesive lined heat shrink sleeves and moulded shapes (heat shrink cable caps, cable breakouts and cable boots) - insulate, seal, protect with heat shrinkable tubing.
This document provides information on explosion-protected floodlight models in the Series 6121. It includes specifications for sizes 2 and 3 IIC models and size 2 IIB models. The lights can be used with various halogen, metal halide, and sodium vapor lamps up to 1000W. They have an aluminum housing, adjustable mounting, and IP66/67 protection. Operating temperatures range from -20°C to +40°C or +55°C. Accessories like lamps and spare parts are also detailed.
This document provides product information on the Predator floodlight by Holophane, including:
- It offers versatility, efficiency, and performance for a variety of lighting needs.
- It can generate wide, narrow, and spot distributions and withstand harsh environments, allowing use in diverse applications.
- Flexibility is maximized with its 360° swivel mounting yoke and quick disconnect removable door for easy maintenance.
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Helashrink heatshrink boots and moulded shapes in conjunction with specialist heatshrink tubing make it easy to fabricate complete jacketed wire and cable harnessing and interconnection systems.
Hellermann Tyton Helashrink heatshrink boots (straight and right-angled) and moulded shapes are available for the complete range of electrical and electronic harnessing applications. Heat shrink boots and shapes can be sealed with special adhesives and encapsulants to ensure the proper degree of mechanical support, strain relief and environmental protection. Encapsulating the complete harnessing and interconnection system to the desired configuration is easily and neatly accomplished with minimum weight and bulk using Hellermann Tyton Helashrink heat shrink components.
Hellermann Tyton Heat Shrink Moulded Shapes & Boots - Overview....
Hellermann Tyton Helashrink heat shrinkable shapes, end caps and cable break-out boots with and without inner adhesive. Hellermannn Tyton heat shrink backshells, 2-way outlet shapes, 3-way outlet shapes, 4-way outlet shapes, 5-way outlet shapes up to 6-way outlet shapes. Hellermann Tyton heat shrink right angle boot 90°, 45°C angle, T-shapes, Y-outlet, VG-style shapes. Heat shrink cable end caps for low voltage applications, two components epoxy adhesive and hot melt tape.
The document is a 4-page datasheet describing 3M's Cold Shrink EPDM Tubes Connector Insulators. It provides information on the product description, features, applications, specifications, and installation techniques. The tubes are open-ended rubber sleeves that are factory-expanded and shrink to form a waterproof seal over cable connections when installed. They can be used for insulation of cable splices and terminations rated up to 1000 volts on cables from 6mm2 to 500mm2. The datasheet includes specifications on sizes available, physical properties of the material, electrical properties, and testing procedures to ensure waterproofing and durability.
The document is a 4-page datasheet describing 3M's Cold Shrink EPDM Tubes Connector Insulators. It provides information on the product description, features, applications, specifications, and installation techniques. The tubes are open-ended rubber sleeves that are factory-expanded and shrink to form a waterproof seal around cable connections when installed. They can be used for insulation of cable splices and terminations rated up to 1000 volts on cables from 6mm2 to 500mm2. The datasheet includes specifications on sizes available, physical properties of the material, and test data demonstrating the product's moisture resistance and electrical performance.
This document provides information on 3M's 8440 Series Silicone Rubber Cold Shrink Lug and Connector Insulators, including:
- Details sizes and application ranges for insulating cable lugs and connectors from 6.86mm to 24.13mm.
- Features like simple installation without tools, maintaining a tight seal over time in various conditions.
- Results from testing the insulators' performance in humidity, UV exposure, thermal shock, fluid resistance and more.
- Physical and electrical properties of the high stretch silicone rubber material.
- Installation and maintenance instructions.
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Applications - Ex Pendant Light Fittings For Hazardous Area Gas & Dust Environments
This document provides information on TMC Co., Ltd's halogen free and mud resistant offshore cables that are compliant with various industry standards. It includes details on cable constructions for high voltage power cables with voltages ranging from 3.6/6kV to 8.7/15kV. Tables provide specifications for different cable types and sizes, listing information like conductor size, insulation thickness, armor wire diameter, nominal diameter and weight. The document also outlines the company's history and certifications obtained for its marine cable products.
Walsall Equipment is a British manufacturer of electrical equipment for hazardous, wet, and dusty environments. It has offices worldwide including Europe, Asia, Africa, and Australia. The company produces a wide range of ATEX-approved products for zone 1, 2, 21, and 22 applications, including junction boxes, lighting, control stations, and cable management systems. It has a purpose-built manufacturing facility with advanced equipment and invests heavily in new technology and product development.
The document describes the SX range of enclosures which are available in either stainless steel or mild steel in various sizes. The enclosures can be fitted with removable gland plates and come with different paint and surface finish options. Cable entries can be drilled in the door, sides, or gland plates. Earthing is accomplished through an internal/external earth stud. The enclosures are suitable for hazardous and industrial applications and provide ingress protection up to IP68.
This document provides information on electrical products and services from Jarel Export for hazardous areas. It describes Jarel Export's specialization in hazardous area electrical products including lighting, control systems, power distribution, motor starters, and other equipment. Technical specifications and certifications are provided for several example products like bolted sockets, cable glands, luminaires, and motors.
Elematic Cabling Systems produces a wide range of cable protection products such as wiring spirals, insulated tubing, heat shrinkable tubing. These products provide optimum chemical resistance, electrical insulation and protection of cables in different applications and industrial installations. Products include polyethylene spirals, braided sleeves in materials like polyester, polyamide and flame retardant PBT, as well as PVC tubing sleeves. These cable protection solutions satisfy cable installation needs across industries.
Lewden Electrical Industries has been supplying Electrical Equipment to Industry for over 60 years, established in 1946, Lewden Metal Products as it was then known, developed an expertise in the Metal Die-casting and Machining of products for the Electrical and Components Industry.
Palazzoli plugs, sockets and interlocked socket outlets for industrial, hazardous area (ATEX certified), marine and general low voltage power distribution, control, protection and signalling devices.
Palazzoli Industrial Overview - Industrial distribution boards, Industrial socket outlets, Industrial plugs, Industrial enclosures, Protection and signalling devices, Lighting appliances, Control devices, Protection devices, Inter-locked socket outlets, Mobile plug and socket outlets, Straight plugs.
Palazzoli ATEX Overview - ATEX plugs, ATEX inter-locked sockets, ATEX enclosures, ATEX protection and signalling devices, ATEX lighting.
Lewden Electrical - Palazzoli ATEX Solutions for Explosive Atmospheres: Industrial Plugs & Sockets, ATEX Enclosures, Cable Glands & Fittings, ATEX Control Devices, Lighting Fixtures & Signalling Devices.
1. The Arctic Pad is a heated rubber mat system developed for arctic and harsh environments to improve on current anti-icing and de-icing methods while providing a durable non-slip surface.
2. It contains self-regulating heat trace embedded in the core that automatically adjusts heating based on temperature without controls.
3. The mat provides advantages over traditional heat tracing like easier installation, improved heat distribution, traction, durability, and lower costs.
This document provides information about electric motors produced by BARTEC VARNOST, including:
- BARTEC VARNOST was established in 1957 and produces flameproof electric motors and electrical equipment.
- The document outlines the construction, materials, dimensions, bearings, shaft ends, load ratings, terminal boxes, protection, and certifications of BARTEC VARNOST electric motors.
- Technical information and standards followed for the motors are also listed, including explosion protection standards and European directives considered in the design and testing of the motors.
This document provides information about UTVFLEX® reeling cables. It includes specifications for various cable models, including voltage ratings, conductor sizes, diameters, weights, and tensile load ratings. The document also provides information on material composition and approvals. UTVFLEX® cables are designed for flexible and mobile power connections under heavy mechanical stresses, for applications such as cranes, conveyors, mining and tunneling equipment.
We are pleased to introduce ourselves as a professionally-managed marketing organization with an objective to become your ‘Single Window for all your requirements of Industrial Electrics’.
We represent the reputed & quality-conscious electrical organizations to serve the following products:
AC Motors & DC Motors
AC Drives
Spare Parts
Junction Boxes - MS/SS/FLP/Thermoplastic
Switchgear - Hensel
The document provides an overview of Siemens' miniature circuit breaker product range, including standard, high-capacity, universal current, high current, and power supply company product lines. It lists the technical specifications for each product line, including rated currents and voltages, tripping characteristics, terminals, approvals, and more. The benefits of the circuit breakers include high rated breaking capacity, excellent current limitation, different tripping characteristics, safety-compliant terminals, uniform additional components, and fast installation. The circuit breakers are designed to protect electrical equipment from overheating and leakage currents.
CE-TEK is a UK-based company established in 1997 that designs and manufactures electrical enclosures for hazardous environments. It employs specialists with decades of experience in the enclosures industry. The company produces a wide range of enclosures made from materials like stainless steel, ABS, polycarbonate, and GRP. These enclosures are certified to ATEX and IEC Ex standards and can withstand temperatures up to 950°C for 3 hours or be submerged to depths of 3000 meters. CE-TEK also offers custom enclosures that meet unique customer and environmental specifications.
Scotch 77 Tape is an arc and fireproofing tape designed to protect electrical cables. It is an unsupported elastomer that expands in fire to form an insulating char layer between the flame and cable. One half-lap wrap of the tape provides adequate protection and can withstand a simulated high current fault arc of 13,000°K for over 70 cycles. The tape is flexible, conforms easily to irregular shapes, and has flame resistant and self-extinguishing properties to protect cables in fire hazards.
This document provides information on solenoid pilot valves for the process industry. It includes:
- A quick selection chart that lists various solenoid pilot valve models with their specifications and characteristics like operating pressure and temperature ranges, materials, connections, and certifications.
- An introduction explaining that ASCO offers products for industries like oil/gas, chemicals, power, and water treatment, and that reliability is important given the operating conditions in these industries.
- Details on features of ASCO's process industry pilot valves including intrinsic safety, low power, communication protocols, and temperature ranges from -50°C to +100°C.
- An image and description highlighting design aspects that improve reliability in aggressive environments like channel
The document provides technical specifications for multiple explosion proof electrical equipment products, including:
1) Control stations that can accommodate various operator configurations and accessories. They are rated for hazardous gas and dust areas and certified to international compliance standards.
2) Push buttons and control stations with mechanical and electrical ratings. Models include various execution options certified for gas and dust hazardous areas.
3) Dimensional and technical data for product lines that include circuit breakers, switches, and push buttons. Specifications include enclosure ratings and temperature classifications.
The document provides information on explosion proof electrical equipment from Feam including earthing clamps, electronic grounding systems, and acoustic signallers.
The earthing clamps (IT25 series) are used to connect tankers to ground during loading and unloading operations. The electronic grounding systems (SM2021 series) are used to verify grounding connections and allow loading/unloading when resistance is less than 20 ohms. The acoustic signallers (ETH2 and S2 series) provide audible alarms in hazardous areas.
This document provides information on Feam switchracks and explosion proof electrical enclosures. It describes the construction and materials used in Feam enclosures, which are made of marine grade aluminum or stainless steel. They are tested and certified for use in hazardous areas. The document outlines ordering information needed such as area classification, applicable standards, and electrical diagrams. It also describes Feam's quality control and testing procedures.
This document provides information on explosion proof lighting fixtures and emergency units. It includes technical specifications for various fluorescent tube lamp and LED lighting fixture models. Dimensions, weights, temperature ratings, certifications and compliance standards are listed. Graphs show light output and beam angle distributions. Instructions are also provided for different mounting options like wall, pole, ceiling or pendant mounting.
This document provides information on multiple control stations and push buttons for use in hazardous areas. It includes:
- Technical specifications for multiple control stations that are classified for gas and dust hazardous areas and certified to European and Russian standards.
- Diagrams showing the configurations and maximum number of operators that can be installed on the control stations.
- Technical data sheets listing the dimensions, material specifications, temperature ratings and other details for the control stations and push buttons.
- Notes that the technical characteristics are subject to change and require confirmation.
So in summary, the document outlines explosion proof electrical equipment for hazardous areas, including multiple control stations and push buttons, and provides the relevant technical specifications and compliance information.
This document provides information on explosion proof cable glands for armored cables. It describes the mechanical characteristics, materials, finishes, seals, and dimensions of the non-barrier and barrier cable gland models. Various models are listed with details on thread size, material options, operating temperature ranges, approvals, and ordering information to specify the correct cable gland based on application needs.
This document provides information on switchracks and explosion proof electrical enclosures manufactured by FEAM, including:
- Details on switchrack and enclosure models like dimensions, materials, and certifications.
- Descriptions of ordering and customization options, quality control processes, and responsibilities during production.
- Explanations of the uses of switchracks for assembling control units and enclosure usage in hazardous areas.
This document provides information on explosion proof lighting fixtures and emergency lighting units made by EVF, including:
- Technical specifications and performance details for various fluorescent lighting fixture models.
- Installation and mounting options like ceiling, pole, and pendant mounting.
- Accessories available including protective guards, reflectors, and mounting hardware.
- Compliance with European and Russian certification standards for use in hazardous areas.
The Rittal Flex-Block base/plinth system provides a freely combinable and toolless base/plinth solution for enclosures. The corner pieces support the enclosure load and allow trim panels to be easily attached or removed with clips. Trim panels are symmetrical and interchangeable in width and depth, providing flexibility. Ordering corner pieces and trim panels separately allows customizing to any application and potential cost savings versus complete base/plinth units. Accessories like punched rails, baying clips, and mounting plates provide cable management and installation options.
The document summarizes the CM Compact Medium enclosure system from Rittal. It has 1-door and 2-door sizes from 600mm to 1200mm widths. It provides more flexibility than the AK enclosures it replaces through interior installation with TS8 accessories, more cable entry space and options, and easier mounting plate installation. It is compatible with TS8 components and accessories to allow infinite configuration possibilities.
The document provides an overview of Rittal's PS 4000s enclosure system, including:
- The PS profile offers maximum stability using a 9-fold profile design with a 24-row 25mm grid hole pattern for universal assembly without manual machining.
- The enclosures are tested to international standards to guarantee high quality and come in various sizes, configurations, and options.
- Product details are provided like materials, finishes, included components, and protection ratings for the different PS 4000s enclosure models.
- Specification tables list the technical details and product codes for the enclosures.
The document discusses the benefits of exercise for mental health. Regular physical activity can help reduce anxiety and depression and improve mood and cognitive functioning. Exercise causes chemical changes in the brain that may help protect against mental illness and improve symptoms.
The document is the Rittal catalogue for 2014/2015 and includes details on Rittal's range of enclosure products including small enclosures, compact enclosures, enclosure systems, IT enclosure systems, console systems, operating housings, and accessories. It provides information on Rittal's polycarbonate enclosures, cast aluminium enclosures, terminal boxes, and bus enclosures. The enclosures range in size from the smallest polycarbonate enclosures to large enclosure systems.
2. SECTION 1L
Incandescent Lighting Fixtures INDEX
Model
Lamp Type / Watt. Certification for Explosion-proof
PAGEIncandescent lamp
IEC UL
20 60 100 150 200 300
VDY ● ● 1L - 1
SYL ● ● Ex e II T1 1L - 4
EML ● ● Ex d IIB T3 1L - 7
EUL ● ● Ex d IIB T3 1L - 9
EULS ●
Ex d IIB T4
Ex DP II 12 IP55
1L - 12
EFL ● ● ●
Ex d IIC T3
Ex d IIC T5
Class I Division 1,2
Group C,D
1L - 15
POLE TYPE Flameproof, Increased Safety, Vaportight Type Pole 1L -19
3. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
VDY Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VDY Series lighting fixtures are used ;
in manufacturing plants,
refineries, chemical,
petrochemical and other industrial
process facilities, wastewater and
sewage treatment plants,
offshore, dockside and other
harbor installations as well as
other heavy industrial
applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in Industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screw neck globe and the
guard are screwed on to the
body applying the reflector in its
position by the guard.
Synthetic rubber gasket is used
between the body and globe, so
that the lamp housing is sealed
against vapors and dusts.
Relamping is easily done by
opening lower half of the guard
and unscrewing the globe.
H.I.D lighting fixture has external
type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating
aluminium
Mounting Box : Cast aluminium
alloy
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
< VDY >
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance Technical Data
IP55 Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V/ DC110V
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Ceiling (Small) VDY 2105 2.2 kg
Ceiling (Large) VDY 2205 4.5 kg
If you need more information, contact us please.⇨
5. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Pendant Type > < VDY 90° Bracket Type >
< VDY Ceiling Type > < VDY 40° Bracket Type >
6. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
SYL Series
Wet Locations
NEMA 3, 3R, 4, 7
Type of Explosion-proof
< SYL >
Increase Safety (Ex e II T1)
Application
SYL Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with
synthetic rubber gaskets, and
the globe assembly is fitted to
the body by three socket head
captive screws.
All joint of lamp housing,
including the joint between the
top body and the terminal
plate, are sealed up with high
quality gaskets so as to restrict
breathing.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting aluminium
Mounting Box : Cast aluminium alloy
External Hardware :
Stainless steel
Compliance Standard Finish
NEMA 3 ,3R, 4, 7
IEC 60079-0, 1
IP55
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Technical Data
WeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V/ DC110V Mounting Type Catalog No. Weight
Rated Wattage 100W/ 200W
Ceiling SYL 2105 3.9 Kg
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
8. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SYL Ceiling Type > < SYL Pendant Type >
< SYL 90° Bracket Type > < SYL 40° Bracket Type >
9. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EML Series
Wet Locations
NEMA 3, 3R, 7
<EML 8024>
Type of Explosion-proof
Flameproof (Ex d IIB T3)
Application
EML Series incandescent lighting fixtures are used ;
for flush or surface mounting on ceiling, wall or
pedant in conduit systems.
in hazardous areas, both indoors and outdoors where
enclosed and gasketed fixtures are required.
in tunnels, building entrances and similar locations,
where moisture, dirt, chemicals, vibration or rough
usage are a problem.
where ignitable concentrations of flammable gases,
vapors, liquids or dusts can exist some of the time
under normal operating conditions.
Features
Designed to exclude dirt, moisture and corrosive
vapors from the interior of the fixtures and the
conduit system.
The globe-guard assembly in installed and removed
as a unit making it necessary to handle only one
piece in relamping.
All fixtures are rugged and corrosion-resistant.
Standard Materials
Enclosure : Cast aluminium alloy
Globe : Heat resistant hard glass
Globe Ring : Cast aluminium alloy
Guard : Stainless steel wire
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certification
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety Corporation),
and the others.
Weight
Mounting Type Catalog No. Weight
Ceiling EML 8024 4.7 Kg
Standard Finish Technical Data
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Electrical Rating
Rated Voltage
AC110V/ 220V/ 240V
DC110V
Rated Wattage 100W/ 150W/ 200W/ 300W
Options
Entry Size 1/2", 3/4", 1"
Guard : Stainless steel
Reflector : Aluminium Dome Reflector
Aluminium 30° Angle Reflector
Pole type pendant
* Atmosphere Temp : -20 ~ 55℃ ℃
Ordering Number
Lamp Watt Pendant Ceiling Bracket Certification
Incandescent Lamp
100 EML 8011 EML 8021 EML 8031
Ex d IIB T3
150 EML 8014 EML 8024 EML 8034
200 EML 8012 EML 8022 EML 8032
300 EML 8013 EML 8023 EML 8033
* For Pole type, see pole section (1L-19)
If you need more information, contact us please.⇨
11. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EUL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T3)
<EUL 3021>
Features
The body is cast in one piece,
and the upper part of which
forms a terminal chamber.
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
The globe holder is fixed to the
base of the body with special
flameproof and weatherproof
flanged joint.
The guard is so constructed that
can be hinged down for
cleaning the globe.
Application
EUL Series lighting fixtures are used ;
in tunnels, building entrances and
similar locations where moisture,
dirt, chemicals or rough usage are
a problem.
in heavy process industries having
environments where flammable or
explosive vapors or gases, or where
combustible dusts are present.
in areas where combustible dusts
and flammable vapors are present
simultaneously.
in hazardous areas, both indoors
and
outdoors where long life and low
maintenance costs are desired.
where high light output is needed
but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids or
dusts can exist some of the time
under normal operating conditions.
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Materials Standard Finish
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EUL 3022 3.7 ㎏
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
12. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
Incandescent Lamp
100 EUL 3011 EUL 3021 EUL 3031 EUL 3041
Ex d IIB T3
200 EUL 3012 EUL 3022 EUL 3032 EUL 3042
* For Pole type, see pole section (1L-19)
Ordering Information Temperature Performance Data
E U L 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition
① ② ③ Type Watt. Temp ( )℃ "d" "DP"
EUL Lighting Fixture① Mounting Type②
Incandescent
100
40 T4 11
1 - Pendant 55 T3 -
Wattage (W)③ 2 - Ceiling
200
40 T4 11
1 - 100 3 - 90° Bracket 55 T3 -
2 - 200 4 - 40° Bracket
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
14. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent / Compact Fluorescent
Lighting Fixtures
EULS Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12 IP55)
Application Features
EULS Series lighting fixtures are used ;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible
dusts and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
< EULS >
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access opening cover for wiring.
Standard Materials
Enclosure :
Die casting aluminium
Globe :
Heat resistant hard glass
Inner Reflector :
High purity aluminium
External Hardware :
Stainless steel
Mounting Box : Cast aluminium
alloy
Compliance & Certification Standard Finish
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079- 0.1
NENA 3.3R.7
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EULS 3021 2.8 ㎏
Rated Wattage IL 100W/ CFL 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
17. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Class I Division 1,2 Group C,D
Flameproof (Ex d IIC T3)
Features
Application
<EFL 6021>
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of
flammable vapors or gases and
where dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.
Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Certification Compliance
UL Listed File No. E 131747
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
NEC - Class I Division 1,2 Group C,D,
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. 240V (120V/ 220V for UL Listed) Pendant EFL 6011 5.3 ㎏
Rated Wattage 100W/ 200W/ 300W Ceiling EFL 6021 5.2 ㎏
Rated Frequency 50Hz/ 60Hz Bulkhead EFL 6043 7.3 ㎏
Entry Size 1/2", 3/4", 1" Bracket EFL 6033 8.1 ㎏
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Incandescent
100 EFL 6011 EFL 6021 EFL 6031 EFL 6041
Class I Division 1,2 Group C,D
Ex d IIC T3
200 EFL 6012 EFL 6022 EFL 6032 EFL 6042
300 EFL 6013 EFL 6023 EFL 6033 EFL 6043
If you need more information, contact us please⇨
19. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIC T5)
<EFL 7014>
Features
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
Use compact fluorescent lamp 20W
instead of incandescent lamp.
Application
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of flammable
vapors or gases and where
dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.
Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Certification Compliance
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS(Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. AC240V Pendant EFL 7014 5.3 ㎏
Rated Wattage Compact Fluorescent 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Compact Fluorescent 20 EFL 7014 EFL 7024 EFL 7034 EFL 7044 Ex d IIC T5
If you need more information, contact us please.⇨
21. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures Pole Type
Explosion proof & Vaportight
Weathertight
NEMA 3, 3R, 5
Lighting
Fixtures
Construction
Lamp
Watt
Catalog Number
Hand Rail Type Pedestal Type
2.5M Height 3.5M Height 2.5M Height 3.5M Height
EFLP Series
Flameproof
Ex d IIB T3
CL I,
GR C,D
60 EFLP 60906-25H EFLP 60906-35H EFLP 60906-25P EFLP 60906-35P
100 EFLP 60910-25H EFLP 60910-25H EFLP 60910-25H EFLP 60910-35H
200 EFLP 60920-25H EFLP 60920-25H EFLP 60920-25H EFLP 60920-35H
EULP Series
Flameproof
Ex d IIB T4
60 EULP 30906-25H EULP 30906-35H EULP 30906-25P EULP 30906-35P
100 EULP 30910-25H EULP 30910-35H EULP 30910-25H EULP 30910-35H
200 EULP 30920-25H EULP 30920-35H EULP 30920-25H EULP 30920-35H
SYLP Series
Increased
Safety
Ex e II T1
60 SYLP 70906-25H SYLP 70906-35H SYLP 70906-25P SYLP 70906-35P
100 SYLP 70910-25H SYLP 70910-35H SYLP 70910-25P SYLP 70910-35P
200 SYLP 70920-25H SYLP 70920-35H SYLP 70920-25P SYLP 70920-35P
VDYP Series
Vapor Tight
IP 54
60 VDYP 10906-25H VDYP 10906-35H VDYP 10906-25P VDYP 10906-35P
100 VDYP 10910-25H VDYP 10910-35H VDYP 10910-25P VDYP 10910-35P
200 VDYP 10920-25H VDYP 10920-35H VDYP 10920-25P VDYP 10920-35P
Features
These pole type fittings are the combinations of lighting units for Flameproof EFLP, EULP series, Increase safety
SYLP series or Vapor tight VDYP series incandescent lighting fittings and goose neck shaped poles.
These fittings are mainly used for tower illumination of chemical plant.
Additionally, fixing and wiring connection of these fittings are recommended to be done with Flameproof EOB or
Increased safety and Heavy duty SBD junction boxes in compliance with the type of protection of lighting units.
Other height not listed in the catalog are also available on request.
Conduit entry-Three(3)-28(1")max. Specify the position and size when ordering.
If you need more information, contact us please.⇨
22. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< Hand Rail Type >
* Length (L) is order made.
(Standard is 2.5M, 3.5M. See front page)
< Pedestal Type >
24. SECTION 2L
H.I.D Lighting Fixtures INDEX
Model
Lamp Type / Watt.
Certification for Explosion-proof
PAGEHigh Pressure Sodium Mercury Vapor Metal Halide
50 70 100 150 200 250 400 100 200 250 400 100 175 250 400 IEC UL
VD ● ● ● ● ● ● ● ● 2L - 1
VS ● ● ● ● ● ● ● ● ● ● ● ● ● 2L - 4
SR ● ● ● ● ● ● ● ● ● ● ● ● ● Ex nR II T3 2L - 7
VG ● ● ● ● ●
Ex nR II T4 IP66
Ex DP II 11
Class I
Division 2
Group A,B,C,D
Class II
Division 1,2
Group E,F,G
Class III
Division 1
2L - 12
VN ● ● ● ● ● ● ● 2L - 15
VZ ● ● ● ● ● ● 2L - 19
AUXILIARY H.I.D AUXILIARY LIGHTING 2L - 23
EVN ● ● ● ● ● ● ●
Ex dnR IIC T4
Ex nR II T4 IP66
Ex DP II 11 IP66
2L - 24
EU ● ● ● ● ●
Ex d IIB T4
Ex DP II 12
2L - 30
EA ● ● ● ● ● ● ●
Ex d IIC T4
Ex d IIB T4
2L - 33
EVS ● ● ● ● ● ● ● ● ● ● Ex de IIC T3 2L - 39
EGS ● ● ● ● ●
Ex d IIC T4
Ex DP II 12
2L - 43
EG ● ● ● ● ● ● ● ● ● ● Ex d IIC T3
Class I Division
1 Group C,D
2L - 46
POLE TYPE Flameproof, Increased Safety, Vaportight Pole Type 2L - 51
SB HID Ballast 2L - 53
Accessary Globe, Guard, Reflector 2L - 55
25. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VD Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VD Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and
other industrial process facilities,
wastewater and sewage
treatment plants, offshore,
dockside and other harbor
installations as well as other heavy
industrial applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in Industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screwneck globe and the
guard are screwed on to the
body applying the reflector in
its position by the guard.
Synthetic rubber gasket is
used between the body and
globe, so that the lamp
housing is sealed against
vapors and dusts.
Relamping is easily done by
opening lower half of the
guard and unscrewing the
globe.
H.I.D lighting fixture has
external type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating aluminium
Mounting Box : Cast aluminium
alloy
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IP55
< VD >
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Ratings Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling (Small) VDNY 32075 8.7 Kg
Ceiling (Large) VDNY 32155 15.5 KgRated Wattage 70W/ 100W/ 150W/ 175W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
27. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Ceiling Type > < VDY 40° Bracket Type >
< VDY Pendant Type > < VDY 90° Bracket Type >
28. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VS Series
Wet Locations
NEMA 3, 3R
Application
< VS >
VS Series lighting fixtures are used ;
in manufacturing plants, refineries, chemical,
petrochemical and other industrial process
facilities, wastewater and sewage treatment plants,
offshore, dockside and other harbor installations
as well as other heavy industrial applications.
in industrial areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
Features
The lighting fixture has simple construction.
Relamping is easily done by opening lower half of
the guard and unscrewing the globe.
H.I.D lighting fixture has external type ballast.
Standard Materials Technical Data
Body : Die casting aluminium
Globe : Heat resistant hard glass
External Hardware : Cast aluminium alloy
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Compliance Entry Size 1/2", 3/4", 1"
IP55
NEMA 3, 3R
Certification
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
Certified by KOSHA (Korea Occupational
Safety & Health Agency), KGS (Korea Gas
Safety Corporation), and the others.
Standard Finish Weight
Natural
If you want another color, contact us
please.
Catalog No. Weight
VSNL 7240 18.8 ㎏
Ordering Number Ordering Information
Lamp Watt Pendant Ceiling
90°
Bracket
40°
Bracket
V S N L 7 1 1 5
① ② ③ ④ ⑤
High
Pressure
Sodium
100 VSNL7110 VSNL7210 VSNL7310 VSNL7410 VS Lighting Fixture①
150 VSNL7115 VSNL7215 VSNL7315 VSNL7415
200 VSNL7120 VSNL7220 VSNL7320 VSNL7420 Lamp Type②
250 VSNL7125 VSNL7225 VSNL7325 VSNL7425 NL - High Pressure Sodium
400 VSNL7140 VSNL7240 VSNL7340 VSNL7440 HL - Metal Halide
Metal
Halide
100 VSHL7110 VSHL7210 VSHL7310 VSHL7410 ML - Mercury Vapour
175 VSHL7117 VSHL7217 VSHL7317 VSHL7417
250 VSHL7125 VSHL7225 VSHL7325 VSHL7425 Model Type③ Lamp Wattage (W)⑤
400 VSHL7140 VSHL7240 VSHL7340 VSHL7440 7 - VS Type 10 - 100
Mercury
Vapor
100 VSML7110 VSML7210 VSML7310 VSML7410 15 - 150
200 VSML7120 VSML7220 VSML7320 VSML7420 Mounting Type④ 17 - 175
250 VSML7125 VSML7225 VSML7325 VSML7425 1 - Pendant 20 - 200
300 VSML7130 VSML7230 VSML7330 VSML7430 2 - Ceiling 25 - 250
400 VSML7140 VSML7240 VSML7340 VSML7440 3 - 90° Bracket 30 - 300
* For Pole type, see pole section (2L-51) 4 - 40° Bracket 40 - 400
If you need more information, contact us please.⇨
30. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VS Ceiling Type > < VS 40° Bracket Type >
< VS Pendant Type > < VS 90° Bracket Type >
31. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
SR Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
< SR >
Non Sparking (Ex nR II T3)
Application
SR Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with synthetic
rubber gaskets, and the globe
assembly is fitted to the body by
three socket head captive
screws.
All joint of lamp housing,
including the joint between the
top body and the terminal plate,
are sealed up with high quality
gaskets so as to restrict
breathing.
The body and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting
aluminium alloy
Mounting Box : Cast aluminium
alloy
External Hardware : Stainless
steelCompliance
NEMA 3 ,3R, 4, 4X, 7
IEC 60079-0, 15
IP55
Standard Finish
Options
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
With Choke or Lead Peak type
Ballast
Technical Data
WeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Enclosure Type Catalog No. Weight
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Small (Ceiling) SRHL 2105 10.3 Kg
Entry Size 1/2", 3/4", 1" Middle (Ceiling) SRHL 2255 19.6 Kg
If you need more information, contact us please.⇨
32. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
100
1/2" SRNL1105 SRNL2105 SRNL3105 SRNL4105
Ex nR II T3
3/4" SRNL1103 SRNL2103 SRNL3103 SRNL4103
150
1/2" SRNL1155 SRNL2155 SRNL3155 SRNL4155
3/4" SRNL1153 SRNL2153 SRNL3153 SRNL4153
200
1/2" SRNL1205 SRNL2205 SRNL3205 SRNL4205
3/4" SRNL1203 SRNL2203 SRNL3203 SRNL4203
250
1/2" SRNL1255 SRNL2255 SRNL3255 SRNL4255
3/4" SRNL1253 SRNL2253 SRNL3253 SRNL4253
400
1/2" SRNL1405 SRNL2405 SRNL3405 SRNL4405
3/4" SRNL1403 SRNL2403 SRNL3403 SRNL4403
Metal
Halide
100
1/2" SRHL1105 SRHL2105 SRHL3105 SRHL4105
3/4" SRHL1103 SRHL2103 SRHL3103 SRHL4103
175
1/2" SRHL1175 SRHL2175 SRHL3175 SRHL4175
3/4" SRHL1173 SRHL2173 SRHL3173 SRHL4173
250
1/2" SRHL1255 SRHL2255 SRHL3255 SRHL4255
3/4" SRHL1253 SRHL2253 SRHL3253 SRHL4253
400
1/2" SRHL1405 SRHL2405 SRHL3405 SRHL4405
3/4" SRHL1403 SRHL2403 SRHL3403 SRHL4403
Mercury
Vapor
100
1/2" SRML1105 SRML2105 SRML3105 SRML4105
3/4" SRML1103 SRML2103 SRML3103 SRML4103
200
1/2" SRML1205 SRML2205 SRML3205 SRML4205
3/4" SRML1203 SRML2203 SRML3203 SRML4203
250
1/2" SRML1255 SRML2255 SRML3255 SRML4255
3/4" SRML1253 SRML2253 SRML3253 SRML4253
400
1/2" SRML1405 SRML2405 SRML3405 SRML4405
3/4" SRML1403 SRML2403 SRML3403 SRML4403
* For Pole type, see pole section (2L-51)
Ordering Information
S R N L 1 1 0 5
① ② ③ ④ ⑤
SR Lighting Fixture① ③ Mounting Type Lamp Wattage (W)④ Entry Size⑤
1 - Pendant 10 - 100 1 - 1"
Lamp Type② 2 - Ceiling 15 - 150 3 - 3/4"
NL - High Pressure Sodium 3 - 90° Bracket 17 - 175 5 - 1/2"
HL - Metal Halide 4 - 40° Bracket 20 - 200
ML - Mercury Vapour 25 - 250
40 - 400
34. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SR 90° Bracket Type > < SR 40° Bracket Type >
< SR Ceiling Type > < SR Pendant Type >
LAMP WATT
Ceiling Type Pendant Type 90° Bracket 40° Bracket
A BØ A BØ A BØ A BØ C
Max. 100W 550 275 310 275 420 275 650 275 345
Max. 250W 640 340 400 340 510 340 710 340 400
Max. 400W 695 385 455 385 565 385 750 385 430
35. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG, VN, VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
< VG > < VN > < VZ >
Type of Explosion-proof Fixture Wattage
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Simultaneous Presence (VN Series)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11)
Lamp V Series Wattage
Type VG VN VZ
HPS 50, 70, 100 150, 200, 250 250, 400
MH 100 175, 250 250, 400
MV 100 200, 250 250, 400
Application in hazardous locations requiring
elevated ambient capability.
in installations where moisture,
dirt, dust, vibration, corrosion
and rough usage are problems.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy construction
and epoxy powder finish provide
excellent resistant to corrosion.
V Series HID lighting fixtures are
used ;
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
in petroleum refineries, chemical,
petrochemical and other heavy
process industry facilities.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
where ignitable concentrations of
flammable gases, vapors or
liquids can exist all of the time
or some of the time under
normal operation conditions.
Features
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Dome and 30°angle reflectors
made of FRP material won't rust,
corrode, dent, chip or peel.
If you need more data, contact us please.⇨
36. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof
Non Sparking (Ex nR II T4 IP66)
Class I Division 2 Group A,B,C,D
Features Standard Materials
Compact, lightweight design is ideal for medium and
low mounting heights.
Cast aluminium alloy construction and epoxy powder
finish provide excellent resistant to corrosion.
Hubs with integral conduit stop and bushing to help
prevent damage to field wiring during installation.
Restricted Breathing Construction : zone 2 only
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket : Porcelain with screw shell
Reflector : High grade aluminium sheet
Guard : Die casting aluminium
Compliance & Certification
< VG >
NEC - Class I Division 2 Group A,B,C,D
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
UL Listed File No. E 131747
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
Options
With Dome Reflector or 30° Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and capacitors
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V Ceiling VGNL 22103 7.7 ㎏
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
37. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
50
1" VGNL 12051 VGNL 22051 VGNL 32051 VGNL 92051
Ex nR II T4 IP66
Class I Division 2
Group A,B,C,D
3/4" VGNL 12053 VGNL 22053 VGNL 32053 VGNL 92053
70
1" VGNL 12071 VGNL 22071 VGNL 32071 VGNL 92071
3/4" VGNL 12073 VGNL 22073 VGNL 32073 VGNL 92073
100
1" VGNL 12101 VGNL 22101 VGNL 32101 VGNL 92101
3/4" VGNL 12103 VGNL 22103 VGNL 32103 VGNL 92103
Metal
Halide
100
1" VGHL 12101 VGHL 22101 VGHL 32101 VGHL 92101
Ex nR II T3 IP66
Class I Division 2
Group A,B,C,D
3/4" VGHL 12103 VGHL 22103 VGHL 32103 VGHL 92103
Mercury
Vapor
100
1" VGML 12101 VGML 22101 VGML 32101 VGML 92101
3/4" VGML 12103 VGML 22103 VGML 32103 VGML 92103
Ordering Information Dimension
<Bracket Type>
<Stanchion Type>
<Ceiling Type> <Pendant Type>
V G N L 1 2 0 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VG Lighting Fixture① Lamp Wattage (W)⑤
05 - 50
Lamp Type② 07 - 70
NL - High Pressure Sodium 10 - 100
HL - Metal Halide
ML - Mercury Vapour
Mounting Type③ Entry Size⑥
1 - Pendant 1 - 1"
2 - Ceiling 3 - 3/4"
3 - Bracket 5 - 1/2"
9 - Stanchion
Input Voltage (V)④
1 - 120 Options⑦
2 - 220 DR - Dome Type Reflector
3 - 110 AR - Angle Type Reflector
4 - 208
5 - 277 IR - Instant Restrike
6 - 240 FU - Fused Type
7 - 230
Temperature Performance Data
Lamp Ambient Class I Non-Sparking
Type Watt. Temp ( )℃ Div. 2 "nR"
High
Pressure
Sodium
50
40 260 (T2B) T4
55 - T4
70
40 260 (T2B) T4
55 - T4
100
40 260 (T2B) T4
55 - T4
Metal
Halide
100
40 - T3
55 - T3
Mercury
Vapor
100
40 280 (T2A) T4
55 - T4
39. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VN Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
< VN >
Type of Explosion-proof
Non Sparking (Ex nR II T3 IP66)
Dust Ignition-proof (Ex DP II 11)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features
Compact, lightweight design is ideal for medium
and low mounting heights.
Wide range of light sources to meet specific
lighting needs - High Pressure Sodium (HPS):
150, 200 and 250W, Mercury Vapour (MV): 200
and 250W, Metal Halide (MH): 175 and 250W.
Restricted Breathing Construction : Zone 2 only
Standard Materials
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector : Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification Compliance Options
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
With Dome Reflector or 30°
Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come
to full brightness immediately
(Non-hazardous location only)Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data Weight
Electrical Rating
Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)
Pendant VNNL 12153 12.6 ㎏
Ceiling VNNL 22153 12.8 ㎏Rated Wattage 150W/ 175W/ 200W/ 250W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
40. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
150
1" VNNL 12151 VNNL 22151 VNNL 32151 VNNL 92151
Ex nR II T3 IP66
Ex DP II 11
3/4" VNNL 12153 VNNL 22153 VNNL 32153 VNNL 92153
200
1" VNNL 12201 VNNL 22201 VNNL 32201 VNNL 92201
3/4" VNNL 12203 VNNL 22203 VNNL 32203 VNNL 92203
250
1" VNNL 12251 VNNL 22251 VNNL 32251 VNNL 92251
3/4" VNNL 12253 VNNL 22253 VNNL 32253 VNNL 92253
Metal
Halide
175
1" VNHL 12171 VNHL 22171 VNHL 32171 VNHL 92171
Ex nR II T3 IP66
Ex DP II 12 IP66
3/4" VNHL 12173 VNHL 22173 VNHL 32173 VNHL 92173
250
1" VNHL 12251 VNHL 22251 VNHL 32251 VNHL 92251
3/4" VNHL 12253 VNHL 22253 VNHL 32253 VNHL 92253
Mercury
Vapor
200
1" VNML 12201 VNML 22201 VNML 32201 VNML 92201
Ex nR II T4 IP66
Ex DP II 11
3/4" VNML 12203 VNML 22203 VNML 32203 VNML 92203
250
1" VNML 12251 VNML 22251 VNML 32251 VNML 92251
3/4" VNML 12253 VNML 22253 VNML 32253 VNML 92253
Ordering Information
V N N L 1 2 1 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VN Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
Lamp Wattage (W)⑤ : Entry Size⑥ Options⑦ 5 - 277
15 - 150 1 - 1" DR - Dome Type Reflector 6 - 240
17 - 175 3 - 3/4" AR - Angle Type Reflector 7 - 230
20 - 200 5 - 1/2" IR - Instant Restrike Type
25 - 250 FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Class I Class II Non-Sparking Dust Ignition
Type Watt. Temp ( )℃ Div. 2 Div. 1 "nR" Proof "DP"
High
Pressure
Sodium
150
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
200
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
250
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
Metal
Halide
175
40 - 160 (T2C) T3 11
55 - T3 -
250
40 300 (T2) 160 (T2C) T3 11
55 - - T3 -
Mercury
Vapor
200
40 325 (T1) 165 (T2B) T4 11
55 - - - -
250
40 325 (T1) 165 (T2B) T4 11
55 - - - -
42. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VN Bracket Type > < VN Stanchion Type >
< VN Ceiling Type > < VN Pendant Type >
43. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof
Non Sparking (Ex nR II T2 IP66)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features Standard Materials
Low ambient capability to -40℃
Wide range of light sources to
meet specific lighting needs - High
Pressure Sodium (HPS): 250 and
400W, Mercury Vapour (MV): 250
and 400W, Metal Halide (MH): 250
and 400W
Restricted Breathing Construction :
Zone 2 only
< VZ >
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector :
Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Options
With Dome Reflector or 30° Angle
Reflector
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come to
full brightness immediately
(Non-hazardous location only)
Compliance
NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V
( See Below)※
Bracket VZNL 32253 18.8 ㎏
Rated Wattage 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
44. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
250
1" VZNL 12251 VZNL 22251 VZNL 32251 VZNL 92251
Ex nR II T3
3/4" VZNL 12253 VZNL 22253 VZNL 32253 VZNL 92253
400
1" VZNL 12401 VZNL 22401 VZNL 32401 VZNL 92401
Ex nR II T2
3/4" VZNL 12403 VZNL 22403 VZNL 32403 VZNL 92403
Metal
Halide
250
1" VZHL 12251 VZHL 22251 VZHL 32251 VZHL 92251
Ex nR II T3
3/4" VZHL 12253 VZHL 22253 VZHL 32253 VZHL 92253
400
1" VZHL 12401 VZHL 22401 VZHL 32401 VZHL 92401
Ex nR II T2
3/4" VZHL 12403 VZHL 22403 VZHL 32403 VZHL 92403
Mercury
Vapor
250
1" VZML 12251 VZML 22251 VZML 32251 VZML 92251
Ex nR II T3
3/4" VZML 12253 VZML 22253 VZML 32253 VZML 92253
400
1" VZML 12401 VZML 22401 VZML 32401 VZML 92401
Ex nR II T2
3/4" VZML 12403 VZML 22403 VZML 32403 VZML 92403
Ordering Information
V Z N L 1 2 2 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VZ Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
5 - 277
Lamp Wattage (W)⑤ Entry Size⑥ Options⑦ 6 - 240
25 - 250 1 - 1" DR - Dome Type Reflector 7 - 230
40 - 400 3 - 3/4" AR - Angle Type Reflector
5 - 1/2" FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Non Sparking
Type Watt. Temp ( )℃ "nR"
High
Pressure
Sodium
250
40 T3
55 T3
400
40 T2
55 T2
Metal
Halide
250
40 T3
55 T3
400
40 T2
55 T2
Mercury
Vapor
250
40 T3
55 T3
400
40 T2
55 T2
46. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VZ Bracket Type > < VZ Ceiling Type >
< VZ Stanchion Type > < VZ Pendant Type >
47. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
Auxiliary Lighting
< Auxiliary Lighting >
About Auxiliary Lighting Features V Series Auxiliary Lighting
Momentary voltage outages or dips
can temporarily extinguish HID
lamps which may require up to ten
minutes to restrike. To provide
illumination during this period,
10~20% of the fixtures should be
specified with auxiliary lighting.
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and
stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy
construction and epoxy powder
finish provide excellent resistant
to corrosion.
Quartz auxiliary is available for
all V Series fixtures (except
those with plastic refractors) by
adding the suffix QAL to the
fixture catalog number.
(Example :
VN NL 1 2 15 1- QAL)
Series VG fixtures with this
option use 100 or 150 watt
quartz lamps. Series VN wattage
fixtures can use up to 250 watt
quartz lamps. Quartz lamps are
not supplied with the fixture
Due to the quartz envelope
surface temperature (exceeding
6000°C), fixtures with this option
are not suitable for Wet
hazardous locations. Contact the
Factory for specific fixture
suitabilities.
Instant Restart
Available for 70-150 Watt VG Series
High Pressure Sodium Fixtures by
adding Suffix "IR" to catalog
number (Ex: VN NL 1 2 15 1 - IR).
Additional instant restart interior
circuitry may decrease High
Pressure Sodium lamp life. Feature
will not affect fixture suitability in
hazardous location applications
Incandescent Auxiliary
With a surface lamp temperature
lower than quartz, incandescent
auxiliary lamps are available for
Series V fixtures.
48. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Flameproof-Non Sparking (Ex dnR IIC T4)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)
Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 50W/ 70W/ 100W/ 150W/
175W/ 200W/ 250W
Rated Frequency 50Hz/ 60Hz
Weight
Entry Sizes 1/2", 3/4", 1"
Mounting Type Catalog No. Weight
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
Pendant EVNNL 1255 11.5 Kg
< EVN >
Standard Finish
Dark Gray
If you want another color, contact us
please.
Certification
Certified by KOSHA (Korea
Occupational Safety & Health Agency),
KGS (Korea Gas Safety Corporation),
and the others.
Compliance
IEC 60079-0, 1, 15
NEMA 3, 3R, 4, 4X, 7, 9
Options
With Dome Reflector or 30°
Angle Reflector with SMC or High
Grade Aluminium
With Choke or Lead Peak type
Ballast
For various voltage from 110V to
240V
For 50Hz/ 60Hz
Application Features
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment plants, offshore,
dockside and other harbor installations as
well as other heavy industrial applications.
wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are found.
in withstands the harshest of corrosive
environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere consisting
of a mixture with air of flammable
substances in the form of gas, vapour or
mist is not likely to occur in normal
operation but, if it does occur, will persist
for a short period only.
where combustible dust, moisture, dirt are
present and vibration, corrosion, rough
usage are problems.
Enclosure in glass fiber
reinforced polyester resin,
provide excellent resistant to
corrosion so have a long life.
Enclosure contain ultraviolet
interception ingredient to
resist transformation.
Easy installation and
maintenance.
Pendant mounting module
equipped with integral hub
set screws for vibration
resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use
of both hands when wiring.
Standard Materials
Housing, mounting modules,
component pallets : Fiberglass
reinforced polyester resin
Globe : Heat resistant hard glass
Gasket : Silicone rubber
Reflector : Fiberglass Reinforced
Polyester
External Hardware : Stainless
steel, Brass
If you need more information, contact us please.⇨
49. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
50
1/2" EVNNL 1055 EVNNL 2055 EVNNL 3055 EVNNL 9055
Ex dnR IIC T4 IP66
Ex nR II T4 IP66
Ex DP II 11 IP66
3/4" EVNNL 1053 EVNNL 2053 EVNNL 3053 EVNNL 9053
70
1/2" EVNNL 1075 EVNNL 2075 EVNNL 3075 EVNNL 9075
3/4" EVNNL 1073 EVNNL 2073 EVNNL 3073 EVNNL 9073
100
1/2" EVNNL 1105 EVNNL 2105 EVNNL 3105 EVNNL 9105
3/4" EVNNL 1103 EVNNL 2103 EVNNL 3103 EVNNL 9103
150
1/2" EVNNL 1155 EVNNL 2155 EVNNL 3155 EVNNL 9155
3/4" EVNNL 1153 EVNNL 2153 EVNNL 3153 EVNNL 9153
200
1/2" EVNNL 1205 EVNNL 2205 EVNNL 3205 EVNNL 9205
3/4" EVNNL 1203 EVNNL 2203 EVNNL 3203 EVNNL 9203
250
1/2" EVNNL 1255 EVNNL 2255 EVNNL 3255 EVNNL 9255
3/4" EVNNL 1253 EVNNL 2253 EVNNL 3253 EVNNL 9253
Metal
Halide
100
1/2" EVNHL 1105 EVNHL 2105 EVNHL 3105 EVNHL 9105
Ex dnR IIC T4 IP66
Ex nR II T3 IP66
Ex DP II 11 IP66
3/4" EVNHL 1103 EVNHL 2103 EVNHL 3103 EVNHL 9103
175
1/2" EVNHL 1175 EVNHL 2175 EVNHL 3175 EVNHL 9175
3/4" EVNHL 1173 EVNHL 2173 EVNHL 3173 EVNHL 9173
250
1/2" EVNHL 1255 EVNHL 2255 EVNHL 3255 EVNHL 9255 Ex dnR IIC T3 IP66
Ex nR II T3 IP663/4" EVNHL 1253 EVNHL 2253 EVNHL 3253 EVNHL 9253
Ordering Information Dimension
E V N N L 1 0 5 5 - DR
① ② ③ ④ ⑤ ⑥
EVN Lighting Fixture① Lamp Type②
NL - High Pressure Sodium
Mounting Type③ HL - Metal Halide
1 - Pendant ML - Mercury Vapour
2 - Ceiling
3 - Bracket Lamp Wattage (W)④
9 - Stanchion 05 - 50
07 - 70
Entry Size⑤ 10 - 100
1 - 1" 15 - 150
3 - 3/4" 17 - 175
5 - 1/2" 20 - 200
25 - 250
Options⑥
DR - Dome Reflector
AR - Angle Reflector
C※ an order Aluminium Reflector instead of FRP Reflector
< Pendant Type > < Ceiling Type >
51. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Electrical Ratings
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)
Rated Voltage AC110V/ 220V/ 240V
Rated Wattage 13W×3, 18W×3, 26W×3
< EVNCL 1263 >
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Pendant EVNCL 1263 9 Kg
Standard Materials
Housing, mounting modules,
component pallets : Fiber glass
reinforced polyester resin
Globe :
Heat resistant hard glass
Gasket : Silicone rubber
Reflector :
Fiber glass Reinforced Polyester
External Hardware :
Stainless steel, Brass
Application Features Certification
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities,
wastewater and sewage treatment
plants, offshore, dockside and other
harbor installations as well as other
heavy industrial applications.
wherever the damaging effects of
water, wind, snow, sleet, hot sun or
any combination of these elements
are found.
in withstands the harshest of
corrosive environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere
consisting of a mixture with air of
flammable substances in the form
of gas, vapour or mist is not likely
to occur in normal operation but, if
it does occur, will persist for a
short period only.
where combustible dust, moisture,
dirt are present and vibration,
corrosion, rough usage are
problems.
Enclosure in glass fiber reinforced
polyester resin, provide excellent
resistant to corrosion so have a
long life.
Enclosure contain ultraviolet
interception ingredient to resist
transformation.
Easy installation and maintenance
Internal type ballast.
Pendant mounting module
equipped with integral hub set
screws for vibration resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use of
both hands when wiring.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X
Standard Finish
Dark Gray
If you want another color,
contact us please.
Options
With Dome Reflector or 30°
Angle Reflector with SMC or
High Grade Aluminium
If you need more information, contact us please.⇨
53. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< EVN Bracket Type > < EVN Stanchion Type >
< EVN Pendant Type > < EVN Ceiling Type >
54. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EU Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12)
< EU >
Application Features
EU Series lighting fixtures are used;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible dusts
and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
Lighting unit and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Lighting unit is screwed onto the
top of the mounting box and the
ballast to the side.
Globe assembly is securely
hinged to the body.
Ballast is a high quality one
maintaining much safety on
strength of enclosure,
weatherproof and temperature
rise.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Standard Materials Certification Compliance
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity
aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Ceiling EUNL 32210 8.6 ㎏
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
55. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Volts Pendant Ceiling
90°
Bracket
40°
Bracket
Certification
High Pressure Sodium
50
100-120 EUNL 31105 EUNL 32105 EUNL 33105 EUNL 34105
Ex d IIB T3
200-220 EUNL 31205 EUNL 32205 EUNL 33205 EUNL 34205
70
100-120 EUNL 31107 EUNL 32107 EUNL 33107 EUNL 34107
200-220 EUNL 31207 EUNL 32207 EUNL 33207 EUNL 34207
100
100-120 EUNL 31110 EUNL 32110 EUNL 33110 EUNL 34110
200-220 EUNL 31210 EUNL 32210 EUNL 33210 EUNL 34210
Metal Halide 100
100-120 EUHL 31110 EUHL 32110 EUHL 33110 EUHL 34110
Ex d IIB T4
200-220 EUHL 31210 EUHL 32210 EUHL 33210 EUHL 34210
Mercury Vapor 100
100-120 EUML 31110 EUML 32110 EUML 33110 EUML 34110
200-220 EUML 31210 EUML 32210 EUML 33210 EUML 34210
* For Pole type, see pole section (2L-51)
Ordering Information Temperature Performance Data
E U N L 3 2 1 1 0 Lamp Ambient Flameproof Dust-Ignition
① ② ③ ④ ⑤ ⑥ Type Watt. Temp ( )℃ "d" "DP"
EU Lighting Fixture① Mounting Type④
H.I.D
50
40 T4 12
1 - Pendant 55 - -
Lamp Type② 2 - Ceiling
70
40 T4 12
NL - H.P.Sodium 3 - 90° Bracket 55 - -
HL - Metal Halide 4 - 40° Bracket
100
40 T4 12
ML - Mercury Vapor 55 - -
Voltage (V)⑤
Type of Lighting Fixture③ 1 - 100-120
3 - EUL Type 2 - 200-220
Wattage (W)⑥
05 - 50, 07 - 70, 10 - 100
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
57. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EA Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
< EA >
Type of Explosion-proof
Flameproof (Ex d IIB T4 H2)
Flameproof (Ex d IIC T4 H2)
Standard Materials
Enclosure : Die casting aluminium alloy
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
Guard : Stainless steel
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Application Features Globe assembly is securely hinged
to the body.
Easy installation and maintenance.
Hinged assembly allows the fixture
to hang free during installation to
permit the use of both hands
when wiring.
Can use compact fluorescent lamp
45W instead of HID lamp without
external ballast.
EA Series lighting fixture are used ;
in heavy process industries having
environments where flammable or
explosive vapors or gases, or
where combustible dusts are
present.
in paint spray booth suitability
provides efficient, economical HID
lighting for paint spray areas.
in hazardous areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in hazardous locations requiring
elevated ambient capability.
in marine applications where water
spray and corrosive atmospheres
are considerations.
Lighting unit and ballast are
constructed separately so as
to protect the ballast from
the heat of the lamp.
Base of the body and the
top of the globe holder have
accurate tapered cylindrical
surfaces and are secured by
four socket head captive
screw.
Lighting unit is screwed onto
the top of the mounting box
and the ballast to the side.
Pendant mounting module
equipped with integral hub
set screws for vibration
resistance.
Globe assembly is securely
hinged to the body.
Compliance & Certification
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Technical Data Lamp Replacement
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
110V/ 120V/ 208V/ 220V/ 240V/ 277V/ 460V
Weight
Mounting Type Catalog No. Weight
Small (Ceiling) EANL 2215 17.3 ㎏
Large (Ceiling) EAML 2240 28.3 ㎏
If you need more information, contact us please.☞
58. Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
150 EANL 2115 EANL 2215 EANL 2315 EANL 2415
Ex d IIC T4200 EANL 2120 EANL 2220 EANL 2320 EANL 2420
250 EANL 2125 EANL 2225 EANL 2325 EANL 2425
400 EANL 2140 EANL 2240 EANL 2340 EANL 2440 Ex d IIB T3
Metal
Halide
175 EAHL 2117 EAHL 2217 EAHL 2317 EAHL 2417
Ex d IIC T4
250 EAHL 2125 EAHL 2225 EAHL 2325 EAHL 2425
400 EAHL 2140 EAHL 2240 EAHL 2340 EAHL 2440 Ex d IIB T3
Mercury
Vapor
200 EAML 2120 EAML 2220 EAML 2320 EAML 2420
Ex d IIC T4
250 EAML 2125 EAML 2225 EAML 2325 EAML 2425
400 EAML 2140 EAML 2240 EAML 2340 EAML 2440 Ex d IIB T3
Dimension Ordering Information
<Ceiling Type> <Pendant Type>
<40°Bracket Type>
<90°Bracket Type>
E A N L 2 1 1 5
① ② ③ ④ ⑤
EA Lighting Fixture① Mounting Type④
1 - Pendant
2 - Ceiling
Lamp Type② 3 - 90° Bracket
NL - High Pressure Sodium 4 - 40° Bracket
HL - Metal Halide
ML - Mercury Vapour ⑤ Lamp Wattage(w)
15 - 150
17 - 175
Model Type③ 20 - 200
2 - EA Type 25 - 250
40 - 400
Temperature Performance Data
Lamp Ambient Flame
Type Watt. Temp ( )℃ Proof "d"
High
Pressure
Sodium
150
40 T4
55 T4
200
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3
Metal
Halide
175
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3
Mercury
Vapor
200
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3