We manufacture following chemicals:
•

Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc

•

Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc

•

Antialgae (Biocides) to prevent from algae and slum at cooling towers

•

Oxygen Scavenger and pH boosters

•

Antifouling agent to prevent from atmospheric dust particles at cooling towers

•

Cooling Towers

We also supply, repair and undertake AMC's of water treatment plants
•

Water Softening Plant

•

DM Plant

•

RO (Reverse Osmosis) Plant

•

Pressure Sand Filter and Activated Carbon filter

We hope that all your future requirements of above products we shall be in your enlisted records
and invited for a fruitful participation in various projects
In the meanwhile, awaiting for your valued enquiries in case you enquire any further details.
Please feel free to contact us
Thanking you and assuring you of our best services at all times.

Regards
VIJAY JAISWAL
KASHVI CHEMICALS & SERVICES

For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts

OUR PRODUCT RANGES IN WATER TREATMENT
•

Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc

•

Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc

•

Antialgae (Biocides) to prevent from algae and slum at cooling towers

•

Oxygen Scavenger and pH boosters

•

Antifouling agent to prevent from atmospheric dust particles at cooling towers

•

Cooling towers

•

Cooling Tower Fills, Sprinklers and spares

WE ALSO DEAL, REPAIR AND UNDERTAKE AMC'S OF WATER TREATMENT PLANTS
LIKE
Sr. No.

Products

1

COOLING TOWER CHEMICALS

2

ANTISCALING AGENTS

3

DE – SCALING AGENT

4

ANTI ALGAE AGENT

5

BIOCIDES

6

BOILER CHEMICALS

7

WATER TESTING KITS

8

pH METER

9

TDS METER

10

RO CHEMICALS

11

RESINS

12

FILTERS

13

COOLING TOWERS

14

COOLING TOWER FILLS

15

SPRINKLERS

For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts

WHY WATER TREATMENT REQUIRES
Water is nature’s best and most available source of heat transfer for cooling
systems and boilers. Whether of drinking quality or not, any water will produce scales
and corrosion in cooling systems and steam processing units unless properly treated to
prevent harmful effects of the feed water.
SCALE & HARMFUL EFFECTS
Water contains considerable amounts of scale forming constituents , for eg,
Calcium and Magnesium carbonates, sulphates, Magnesium hydroxide, Silica etc. The
scale deposit on metal parts and inside pipeline of heat exchangers, evaporators,
boilers, compressors, solar heaters, Generators, AC units and water cooling circuits.
The adherent scales impede heat transfer capacity of the unit (Heat Conduction
Capacity of hard water scale is only 3.8 % of Steel). Thus, requiring 12 % more fuel
(through 1/16” scale in boiler) to achieve the same heat transfer. In practice, thickness
of the scale may be much higher. In a similar way, scales work as insulation for heat
transfer in exchangers, compressors and generators which result in energy loss and
higher pressure attack, metal failure at hot spots and reduction in the capacity of heat
transfer tubes.
WATER TREATMENT SOLUTIONS
The loss of energy, downtime of various equipments and replacement of
expensive tubes and components can be prevented by periodic scale cleaning.
Mechanical removal of scales involving inaccessible areas of the assembled unit is
difficult. Chemical cleaning is more efficient in these positions.
In addition to scale cleaning, number of Water Treatment compounds
have been formulated to prevent scaling, corrosion and Algae that will keep the
equipment clean and efficient for period of usage.

For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts

OUR PRODUCT RANGE, APPLICATION & METHODS
DESCALING OF BOILERS & COOLING SYSTEMS
PRODUCTS

APPLICATION

DOSAGE

METHADOLOGY

KC 201

Cleaning of boilers’ steam
Processing unit

15% to 20% in
water

Forced circulation in system by pump
10 to 15 hours till scales are removed

KC 203

Cleaning of chiller

15% to 20 % in
water

Forced circulation in system by pump

KC 204

For neutralizing & washing of
system (passivating agent)

3% to 5% in water

Forced circulation in system by pump
for 1 to 2 hours

KC 209

Descaling of water-cooling
System

4% to 5% in water

Forced circulation in system by pump
4 to 6 hours till scales are removed

KC - 205

Descaling of water-cooling
System

5% to 8% in water

Forced circulation in system by pump
5 to 8 hours till scales are removed

BOILER WATER TREATMENT
PRODUCTS

APPLICATION

DOSAGE

METHADOLOGY

KC 701

Single Chemical Treatment
For prevention of scaling &
Corrosion in small boilers

100 to 200 ppm of
make-up water as
recommended

Regular dosing of boiler make-up
water tank

KC 702

Single Chemical Treatment
For prevention of scaling &
Corrosion for other boilers

70 to 150 ppm of
make-up water as
recommended

Regular dosing of boiler make-up
water tank

KC 703

Single Chemical Treatment
For prevention of scaling

150 to 250 ppm as
above

Regular dosing of boiler make-up
water tank

KC 704

Single Chemical Treatment
For prevention of corrosion &
maintain pH boiler’s water

50 to 100 ppm of
make-up water as
recommended

Regular dosing of boiler make-up
water tank

For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts

COOLING WATER TREATMENT
PRODUCTS

APPLICATION

DOSAGE

KC 202
(Antifouling)

To Settle Atmospheric Dust in
Cooling Tower Tank

100 to 200 PPM of
makeup water

Addition in cooling water reservoir
with pH adjustment

KC 601

Single Chemical Treatment
for the small cooling system
preventing scale only

200 to 300 ppm of
make-up water

Clean the water tank & add KC601 at
regular intervals with adjustment of
pH in system

KC 602

Single Chem. Treatment for
raw water recirculation
system preventing scale &
corrosion

100 to 150 ppm of
make-up water

Addition in cooling water reservoir
with pH adjustment

KC 603

Single Chem. Treatment for
soft water recirculation
system preventing scale &
corrosion

50 to 100 ppm of
make-up water

Addition in the cooling water tank with
pH adjustment

KC 604

Specially designed
formulation for prevention of
scaling and corrosion
(Chillers etc)

5 to 20 % of makeup water

KC 605

Prevention of Algae & Slime

Initial dose of 200
ppm

Shock doses at intervals of one

For cooling water tanks

followed by 100
ppm make-up
water

Shock doses at intervals of one week

KC 606
(Biocide)

METHADOLOGY

Dosing to full coolant upto
recommended mark
Refill the whole water with contents
250 hours of running

For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.

Introduction & Product Range

  • 1.
    Manufacturer of watertreatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO Membranes and other spare parts To, Dear Sir, We have great pleasure to introduce ourselves as one of the leading manufacturers of Water Treatment Chemicals, supplier of Cooling towers and Water Treatment Plants. We also undertake job work such as Descaling and AMC's for Boilers, water cooling system. We manufacture following chemicals: • Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc • Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc • Antialgae (Biocides) to prevent from algae and slum at cooling towers • Oxygen Scavenger and pH boosters • Antifouling agent to prevent from atmospheric dust particles at cooling towers • Cooling Towers We also supply, repair and undertake AMC's of water treatment plants • Water Softening Plant • DM Plant • RO (Reverse Osmosis) Plant • Pressure Sand Filter and Activated Carbon filter We hope that all your future requirements of above products we shall be in your enlisted records and invited for a fruitful participation in various projects In the meanwhile, awaiting for your valued enquiries in case you enquire any further details. Please feel free to contact us Thanking you and assuring you of our best services at all times. Regards VIJAY JAISWAL KASHVI CHEMICALS & SERVICES For more details, Contact at anyone of the offices: AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003 NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001. Mob: 9923878975, 8888868765 Email: kashvichemicals@gmail.com.
  • 2.
    Manufacturer of watertreatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO Membranes and other spare parts OUR PRODUCT RANGES IN WATER TREATMENT • Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc • Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc • Antialgae (Biocides) to prevent from algae and slum at cooling towers • Oxygen Scavenger and pH boosters • Antifouling agent to prevent from atmospheric dust particles at cooling towers • Cooling towers • Cooling Tower Fills, Sprinklers and spares WE ALSO DEAL, REPAIR AND UNDERTAKE AMC'S OF WATER TREATMENT PLANTS LIKE Sr. No. Products 1 COOLING TOWER CHEMICALS 2 ANTISCALING AGENTS 3 DE – SCALING AGENT 4 ANTI ALGAE AGENT 5 BIOCIDES 6 BOILER CHEMICALS 7 WATER TESTING KITS 8 pH METER 9 TDS METER 10 RO CHEMICALS 11 RESINS 12 FILTERS 13 COOLING TOWERS 14 COOLING TOWER FILLS 15 SPRINKLERS For more details, Contact at anyone of the offices: AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003 NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001. Mob: 9923878975, 8888868765 Email: kashvichemicals@gmail.com.
  • 3.
    Manufacturer of watertreatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO Membranes and other spare parts WHY WATER TREATMENT REQUIRES Water is nature’s best and most available source of heat transfer for cooling systems and boilers. Whether of drinking quality or not, any water will produce scales and corrosion in cooling systems and steam processing units unless properly treated to prevent harmful effects of the feed water. SCALE & HARMFUL EFFECTS Water contains considerable amounts of scale forming constituents , for eg, Calcium and Magnesium carbonates, sulphates, Magnesium hydroxide, Silica etc. The scale deposit on metal parts and inside pipeline of heat exchangers, evaporators, boilers, compressors, solar heaters, Generators, AC units and water cooling circuits. The adherent scales impede heat transfer capacity of the unit (Heat Conduction Capacity of hard water scale is only 3.8 % of Steel). Thus, requiring 12 % more fuel (through 1/16” scale in boiler) to achieve the same heat transfer. In practice, thickness of the scale may be much higher. In a similar way, scales work as insulation for heat transfer in exchangers, compressors and generators which result in energy loss and higher pressure attack, metal failure at hot spots and reduction in the capacity of heat transfer tubes. WATER TREATMENT SOLUTIONS The loss of energy, downtime of various equipments and replacement of expensive tubes and components can be prevented by periodic scale cleaning. Mechanical removal of scales involving inaccessible areas of the assembled unit is difficult. Chemical cleaning is more efficient in these positions. In addition to scale cleaning, number of Water Treatment compounds have been formulated to prevent scaling, corrosion and Algae that will keep the equipment clean and efficient for period of usage. For more details, Contact at anyone of the offices: AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003 NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001. Mob: 9923878975, 8888868765 Email: kashvichemicals@gmail.com.
  • 4.
    Manufacturer of watertreatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO Membranes and other spare parts OUR PRODUCT RANGE, APPLICATION & METHODS DESCALING OF BOILERS & COOLING SYSTEMS PRODUCTS APPLICATION DOSAGE METHADOLOGY KC 201 Cleaning of boilers’ steam Processing unit 15% to 20% in water Forced circulation in system by pump 10 to 15 hours till scales are removed KC 203 Cleaning of chiller 15% to 20 % in water Forced circulation in system by pump KC 204 For neutralizing & washing of system (passivating agent) 3% to 5% in water Forced circulation in system by pump for 1 to 2 hours KC 209 Descaling of water-cooling System 4% to 5% in water Forced circulation in system by pump 4 to 6 hours till scales are removed KC - 205 Descaling of water-cooling System 5% to 8% in water Forced circulation in system by pump 5 to 8 hours till scales are removed BOILER WATER TREATMENT PRODUCTS APPLICATION DOSAGE METHADOLOGY KC 701 Single Chemical Treatment For prevention of scaling & Corrosion in small boilers 100 to 200 ppm of make-up water as recommended Regular dosing of boiler make-up water tank KC 702 Single Chemical Treatment For prevention of scaling & Corrosion for other boilers 70 to 150 ppm of make-up water as recommended Regular dosing of boiler make-up water tank KC 703 Single Chemical Treatment For prevention of scaling 150 to 250 ppm as above Regular dosing of boiler make-up water tank KC 704 Single Chemical Treatment For prevention of corrosion & maintain pH boiler’s water 50 to 100 ppm of make-up water as recommended Regular dosing of boiler make-up water tank For more details, Contact at anyone of the offices: AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003 NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001. Mob: 9923878975, 8888868765 Email: kashvichemicals@gmail.com.
  • 5.
    Manufacturer of watertreatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO Membranes and other spare parts COOLING WATER TREATMENT PRODUCTS APPLICATION DOSAGE KC 202 (Antifouling) To Settle Atmospheric Dust in Cooling Tower Tank 100 to 200 PPM of makeup water Addition in cooling water reservoir with pH adjustment KC 601 Single Chemical Treatment for the small cooling system preventing scale only 200 to 300 ppm of make-up water Clean the water tank & add KC601 at regular intervals with adjustment of pH in system KC 602 Single Chem. Treatment for raw water recirculation system preventing scale & corrosion 100 to 150 ppm of make-up water Addition in cooling water reservoir with pH adjustment KC 603 Single Chem. Treatment for soft water recirculation system preventing scale & corrosion 50 to 100 ppm of make-up water Addition in the cooling water tank with pH adjustment KC 604 Specially designed formulation for prevention of scaling and corrosion (Chillers etc) 5 to 20 % of makeup water KC 605 Prevention of Algae & Slime Initial dose of 200 ppm Shock doses at intervals of one For cooling water tanks followed by 100 ppm make-up water Shock doses at intervals of one week KC 606 (Biocide) METHADOLOGY Dosing to full coolant upto recommended mark Refill the whole water with contents 250 hours of running For more details, Contact at anyone of the offices: AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003 NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001. Mob: 9923878975, 8888868765 Email: kashvichemicals@gmail.com.