IBM Easy-Connect
   System Networking
   - Transparent Mode
   - Multi-chassis Mode (PureFlex ONLY)
   - Customer Examples                        EN/CN4093 and Virtual Fabric Switch Module




Design and configuration by Scott Irwin & Igor Marty                      © 2013 IBM Corporation
What is Easy-Connect

    • Clever pass-through = Simple I/O module connecting servers,
      storage and the Core network

    • Aggregation = Server ports aggregated together towards Core
      Network

    • No network integration = Seen as one big pipe with server traffic
      coming in and out.

    • No Spanning-Tree = No loops, no network integration

    • Similar to Cisco FEX – with one important exception, server to
      server traffic stays local to chassis.

    • Specific Networking features (Virtual Fabric Mode, VMready etc…)
      can still be activated on selected ports when/if needed.



2                                                                         © 2013 IBM Corporation
Transparent Mode




                   © 2013 IBM Corporation
Easy-Connect
- Transparent Mode
Easy-Connect Transparent Mode
                             •   Looks like a “dumb” device to Nexus 5K/Edge Switch
                             •   No Spanning Tree Protocol (STP) – eliminates Network admin loop concerns
                             •   Provides traffic consolidation in the chassis to minimize ToR port utilization
                             •   Provides intra-chassis switching, even in Transparent Mode

Client Benefits
                             •   Allows client to manage networking from the Edge/Nexus management system
                             •   Allows for intra-chassis switching for optimal performance (i.e. vMotion)
                             •   Allows for pay as you grow expandability in the chassis, both to the network and the compute
                                 nodes.
 Networking Infrastructure




                             •   VLAN’s are transparent when in “Transparent Mode” between the NIC and Edge Switch
                             •   Allows for pNIC or Switch Independent vNIC to be utilized
                                   • Note: Power Nodes supported in pNIC mode only
                             •   Allows for growth into “Virtual Fabric Mode” using multiple groups and uplinks
                             •   Allows for FCoE if ONLY using a single Uplink (FCoE currently not supported over PortChannel)

How to set the I/O Switch into Transparent Mode
                             •  Set the uplinks as one logical unit via Static Port-Channel (note: VFSM support LACP when using
                                vNIC Groups)
                             • Turn on vNIC and configure all internal “ports” and external “port-channel” into vNIC “Group 1”
                             • Turn on Spanning Tree BPDU Guard and Edge on the Edge/Nexus Switch for additional
                                protection
                             Note: If connecting to a Nexus 2k both BPDU Guard and Edge are already enabled by default and
                                cannot be disabled.
                             • Works with PureFlex Chassis EN/CN4093 and Virtual Fabric Switch Modules
                             • If using FCoE over a single link simply enable CEE Globally (cee enable)              © 2013 IBM Corporation
Easy-Connect
Configuration to convert from Switch Mode to Transparent Mode
Configuration for the IBM VFSM and EN/CN4093
•ssh to each VFSM,EN/CN4093
•boot the VFSM,EN/CN4093 to use isCLI (Cisco-Like CLI) for a more familiar look
      • /boot/mode iscli
      • /boot/reset
      • /boot/prompt enable           enable if using FSM on PureFlex
•Set the following commands to convert to “Transparent Mode”
      • ssh to each VFSM
      • enter into enable mode (e.g. enable)
      • enter into configuration terminal mode (e.g. config t)
      • type the following; (start with factory default configuration)                                         vLAG
 Networking Infrastructure




                                                                           Switch               Switch          vPC
             “boot conf factory”
             ===========Begin Script ===========
             spanning-tree mode disable                                                                     LACP
             interface port ext1-ext10
             lacp key 1001                                                  VFSM 1             VFSM 2
             lacp mode active
                vnic enable
                vnic vnicgroup 1
                vlan 4091
                port int1-int14
                adminkey 1001                                                        Node
                enable
                failover
             exit                                                                    Chassis
             write memory
             ===========End Script ===========                                                  © 2013 IBM Corporation
Easy-Connect
Configuration to convert from Switch Mode to Transparent Mode w/FCoE
Configuration for the IBM VFSM and EN/CN4093
•ssh to each VFSM
•boot the VFSM to use isCLI (Cisco-Like CLI) for a more familiar look
      • /boot/mode iscli
      • /boot/reset
•Set the following commands to convert the VFSM to “Transparent Mode”
      • ssh to each VFSM
      • enter into enable mode (e.g. enable)
      • enter into configuration terminal mode (e.g. config t)
      • type the following; (start with factory default configuration)
             “boot conf factory”                                                                             vLAG
 Networking Infrastructure




                                                                         Switch              Switch           vPC
             ===========Begin Script ===========
             spanning-tree mode disable
             interface port ext1-ext4                                                                    LACP
             lacp key 1001
             lacp mode active                                            VFSM 1             VFSM 2
                vnic enable
                vnic vnicgroup 1
                vlan 4091
                port int1-int14
                adminkey 1001
                enable                                                            Node
                failover
             exit
             cee enable                                                           Chassis
             write memory
             ===========End Script ===========                                                © 2013 IBM Corporation
Multi-Chassis Mode




                     © 2013 IBM Corporation
Easy-Connect
- Multi-chassis Mode
  Easy-Connect Multi-chassis Mode
                             •   Allows G8264 and EN/CN4093 look like a “dumb” device to Edge/Nexus Switches
                             •   No Spanning Tree Protocol (STP) Required – eliminates Network admin loop concerns
                             •   Provides traffic consolidation in the chassis to minimize ToR port utilization
                             •   Provides intra chassis switching, even in Easy-Connect Mode
                             •   Works with EN/CN4093 ONLY as VFSM does NOT support vLAG

  Client Benefits
                             •   Allows client to manage networking from the Edge/Nexus management system
                             •   Allows for intra/external chassis switching for optimal performance (i.e. vMotion)
 Networking Infrastructure




                             •   Allows for pay as you grow expandability in the chassis, both to the network and the
                                 compute nodes.
                             •   VLAN’s are transparent on both G8264 and EN/CN4093 when in “Easy-Connect Mode”
                                 between the NIC and Upstream AGG/Core Switch
                             •   Allows for pNIC or Switch Independent vNIC to be utilized
                             •   Allows for growth into Virtual Fabric Mode
                             •   Note: Power Nodes supported in pNIC mode only

  Use cases for Multi-Chassis Mode
                             •   Works with environments that require Active/Active NIC Teaming and or Bonding using
                                 802.3ad and or Static EtherChannels on the NODE Ports
                             •   Works with both Intel and Power Nodes
                             •   ALL local Layer 2 Traffic, even if using different I/O Bays, will remain within the same
                                 enclosure with the use of the ISL Peer-Links between the EN/CN4093’s
                             •   Each Chassis appears to upstream Network as a single entity
                                                                                                                    © 2013 IBM Corporation
Easy-Connect
What you end up with in Multi-chassis Mode with vLAG and vPC
How-To: EN/CN4093 Easy-Connect Multi-chassis Mode

     Disable Global Spanning Tree

     Set all VFSM ports, both EXT Ports facing the Network (Top of
     Rack) and INT Ports, into tagpvid-ingress using VLAN 4091 as     Switch               Switch
                                                                                                          vLAG
                                                                                                          or vPC
     the PVID

     Enable TAGGING on the two EXT Ports being used as the vLAG
     Peer Link and set 4090 as the PVID adding VLAN 4091 as a                     LACP
     TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG
     ISL VLAN)                                                       EN/CN4093            EN/CN4093        vLAG

     Configure all required LACP PortChannels (Peer Link, EXT, and               LACP
     INT Ports)

     Configure a dummy IP Address used by the MGT EXT Port
                                                                                 Node
     vLAG Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2))
                                                                                 X or P
     Configure vLAG ISL, Health Check peer-ip, and all associated
                                                                                 Chassis
     vLAG pairs


NOTE: Turning on Spanning Tree BPDU Guard and Edge on the
EDGE G8264 / Nexus 5K Switches can provide further protection

                                                                                            © 2013 IBM Corporation
Easy-Connect
If using G8264’s in ToR also in Multi-Chassis Transparent Mode
How-To: G8264 Easy-Connect Multi-chassis Mode
                                                                      vPC   AGG/Core             AGG/Core
     Disable Global Spanning Tree (not required (default is using
     Rapid PVST+ (i.e. PVRST)))                                      LACP

     Set all G8264 ports, both uplink facing network and enclosure   vLAG   G8264-1              G8264-2
     facing EN/CN4093’s, into tagpvid-ingress using VLAN 4091 as
     the PVID

     Enable TAGGING on the two ISL Ports being used as the vLAG                LACP                LACP
     Peer-Link and set 4090 as the PVID adding VLAN 4091 as a
     TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG            vLAG   EN/CN4093            EN/CN4093
     ISL VLAN)
                                                                                        LACP
     Configure all required LACP PortChannels (Peer Link, Uplinks,
     and EN/CN4093 facing ports)
                                                                                        Node
     Configure a dummy IP Address used by the MGT Port vLAG
                                                                                        X or P
     Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2))
     NOTE: if using customers MGT Network set IP’s appropriately
                                                                                       Chassis

     Configure vLAG ISL, Health Check peer-ip, and all associated
     vLAG pairs


NOTE: Turning on Spanning Tree BPDU Guard and Edge on the
EDGE G8264 / Nexus 5K Switches can provide further protection                             © 2013 IBM Corporation
Customer requirements to implement Easy-Connect

     1. If using FSM in same chassis – since the FSM is NOT capable of TAGGING
        (Cisco Trunking) customer MUST enable the Top-of-Rack Port “Native
        VLAN ID” with the VLAN that the FSM needs to be configured on.

     2. ALL other OS’s (i.e. VMware, VIO, and even Bare Metal OS’s) within the
        PureFlex Chassis are required to TAG/Trunk VLAN’s.

     3. If using multiple vNIC Groups for traffic either traffic separation and or if
        using Virtual Fabric Mode - each vNIC Group requires it’s own
        uplink/PortChannel or DUM (Dedicated Uplink Mode)


     4. If Multi-Tenant security is a concern within the same PureFlex Chassis
        Easy-Connect may/may not be a good option. Why, because each vNIC
        Group is a single broadcast domain.

     5. If IGMP Multicast Snooping is required Easy-Connect may not be a best
        option. Since Easy-Connect is VLAN Agnostic IGMP Snooping is not
        supported in any Q-n-Q Architecture. However, Multicast will still pass
        through the Easy Connect enabled Switches.
11                                                                               © 2013 IBM Corporation
Easy Connect
Customer Examples




                    © 2013 IBM Corporation
Easy-Connect EN/CN4093
Transparent Mode – Telecom Customer (Very Simple)
 Requirements included:
 •No Spanning Tree and or any other protocols seen by the network (Easy-Connect)
 •Connection into Nexus 2k (no vPC or vLAG requirement)
 •EN4093 is to be a total transparent device requiring no management by any group




                                                                                    © 2013 IBM Corporation
Easy-Connect EN/CN4093
Transparent Mode – State Government
 Requirements included:
 •Using LoM in Virtual Fabric Mode so bandwidth can be adjusted on the fly for each vNIC as required
 •Dedicated uplink vPC PortChannel from each EN4093 for each vNIC Group for separation of traffic
 •EN4093’s in Transparent Mode with minimal hands-on requirement (vNIC BW ONLY)




                                                                                           © 2013 IBM Corporation
Easy-Connect EN/CN4093
Storage Mode w/NIC Redundancy – Medical Center
 Requirements included:
 •Dedication and Separation of Fiber Channel and Ethernet from Each NODE and Enclosure
 •Total Hardware Redundancy including NIC and ASIC on every NODE (CN4054 Mezz)
 •Transparency on both Ethernet (Easy-Connect) and Fiber Channel (NPV)




                                                                                         © 2013 IBM Corporation
Backup Slides




                © 2013 IBM Corporation
Four Scalable switches enable high speed connectivity – Ethernet
 (FCoE, iSCSI), Fibre Channel and InfiniBand




                                                  Four high
                                                 performance
                                                Scalable Switch
                                                   Modules




                        3    2     4
                  1




17
17                                                          © 2013 IBM Corporation
Robust connectivity: Switch, asic and adapter level redundancy
                                         Redundant pair
     asic level redundancy                                                     Redundant pair




                                     EN4093 (base)




                                                          EN4093 (base)




                                                                                                           EN4093 (base)
                                                                                     EN4093 (base)
            asic 1




            asic 2


  CN4054




                                     EN4093 (Upgrade 1)




                                                          EN4093 (Upgrade 1)




                                                                                                           EN4093 (Upgrade 1)
                                                                                      EN4093 (Upgrade 1)
            asic 1




            asic 2


   CN4054

                                       1                      3                          2                    4
Adapter level redundancy                                                                                   © 2013 IBM Corporation

More Related Content

What's hot

Cisco nexus series
Cisco nexus seriesCisco nexus series
Cisco nexus seriesAnwesh Dixit
 
Cisco data center support
Cisco data center supportCisco data center support
Cisco data center supportKrunal Shah
 
Juniper Networks: Virtual Chassis High Availability
Juniper Networks: Virtual Chassis High AvailabilityJuniper Networks: Virtual Chassis High Availability
Juniper Networks: Virtual Chassis High AvailabilityJuniper Networks
 
Matching Cisco and System p
Matching Cisco and System pMatching Cisco and System p
Matching Cisco and System pAndrey Klyachkin
 
vPC techonology for full ha from dc core to baremetel server.
vPC techonology for full ha from dc core to baremetel server.vPC techonology for full ha from dc core to baremetel server.
vPC techonology for full ha from dc core to baremetel server.Ajeet Singh
 
Virtual Routing and Forwarding, (VRF-lite)
Virtual Routing and Forwarding, (VRF-lite)Virtual Routing and Forwarding, (VRF-lite)
Virtual Routing and Forwarding, (VRF-lite)NetProtocol Xpert
 
Creating Competitive Advantage by Revolutionizing I/O
Creating Competitive Advantage by Revolutionizing I/OCreating Competitive Advantage by Revolutionizing I/O
Creating Competitive Advantage by Revolutionizing I/OEmulex Corporation
 
Inter VLAN Routing
Inter VLAN RoutingInter VLAN Routing
Inter VLAN RoutingNetwax Lab
 
From virtual to high end HW routing for the adult
From virtual to high end HW routing for the adultFrom virtual to high end HW routing for the adult
From virtual to high end HW routing for the adultMarketingArrowECS_CZ
 
KPUCC-Rs instructor ppt_chapter3_final
KPUCC-Rs instructor ppt_chapter3_finalKPUCC-Rs instructor ppt_chapter3_final
KPUCC-Rs instructor ppt_chapter3_finalFisal Anwari
 
VDC by NETWORKERS HOME
VDC by NETWORKERS HOMEVDC by NETWORKERS HOME
VDC by NETWORKERS HOMEnetworkershome
 
Juniper round table switching and product overview
Juniper round table   switching and product overviewJuniper round table   switching and product overview
Juniper round table switching and product overviewKappa Data
 

What's hot (20)

Juniper for Enterprise
Juniper for EnterpriseJuniper for Enterprise
Juniper for Enterprise
 
Cisco nexus series
Cisco nexus seriesCisco nexus series
Cisco nexus series
 
Cisco data center support
Cisco data center supportCisco data center support
Cisco data center support
 
Day 14.2 configuringvla ns
Day 14.2 configuringvla nsDay 14.2 configuringvla ns
Day 14.2 configuringvla ns
 
Juniper Networks: Virtual Chassis High Availability
Juniper Networks: Virtual Chassis High AvailabilityJuniper Networks: Virtual Chassis High Availability
Juniper Networks: Virtual Chassis High Availability
 
Matching Cisco and System p
Matching Cisco and System pMatching Cisco and System p
Matching Cisco and System p
 
vPC techonology for full ha from dc core to baremetel server.
vPC techonology for full ha from dc core to baremetel server.vPC techonology for full ha from dc core to baremetel server.
vPC techonology for full ha from dc core to baremetel server.
 
Virtual Routing and Forwarding, (VRF-lite)
Virtual Routing and Forwarding, (VRF-lite)Virtual Routing and Forwarding, (VRF-lite)
Virtual Routing and Forwarding, (VRF-lite)
 
Creating Competitive Advantage by Revolutionizing I/O
Creating Competitive Advantage by Revolutionizing I/OCreating Competitive Advantage by Revolutionizing I/O
Creating Competitive Advantage by Revolutionizing I/O
 
WAN - trends and use cases
WAN - trends and use casesWAN - trends and use cases
WAN - trends and use cases
 
Inter VLAN Routing
Inter VLAN RoutingInter VLAN Routing
Inter VLAN Routing
 
Chapter 10
Chapter 10Chapter 10
Chapter 10
 
From virtual to high end HW routing for the adult
From virtual to high end HW routing for the adultFrom virtual to high end HW routing for the adult
From virtual to high end HW routing for the adult
 
KPUCC-Rs instructor ppt_chapter3_final
KPUCC-Rs instructor ppt_chapter3_finalKPUCC-Rs instructor ppt_chapter3_final
KPUCC-Rs instructor ppt_chapter3_final
 
Vlans_routing
Vlans_routingVlans_routing
Vlans_routing
 
VDC by NETWORKERS HOME
VDC by NETWORKERS HOMEVDC by NETWORKERS HOME
VDC by NETWORKERS HOME
 
Juniper Switch Overview
Juniper Switch OverviewJuniper Switch Overview
Juniper Switch Overview
 
Juniper round table switching and product overview
Juniper round table   switching and product overviewJuniper round table   switching and product overview
Juniper round table switching and product overview
 
Introduction to routers
Introduction to routersIntroduction to routers
Introduction to routers
 
4cfrelay
4cfrelay4cfrelay
4cfrelay
 

Viewers also liked

NIC Virtualization on IBM Flex Systems
NIC Virtualization on IBM Flex SystemsNIC Virtualization on IBM Flex Systems
NIC Virtualization on IBM Flex SystemsAngel Villar Garea
 
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable SwitchesIBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable SwitchesIBM India Smarter Computing
 
Ibm pure flex overview cust pr
Ibm pure flex overview cust prIbm pure flex overview cust pr
Ibm pure flex overview cust prNatalija Pavic
 
IBM Systems of Interaction
IBM Systems of InteractionIBM Systems of Interaction
IBM Systems of InteractionIBM Sverige
 
Microsoft Exchange 2013 architecture
Microsoft Exchange 2013 architectureMicrosoft Exchange 2013 architecture
Microsoft Exchange 2013 architectureMotty Ben Atia
 
Cloud computing Basics
Cloud computing BasicsCloud computing Basics
Cloud computing BasicsSagar Sane
 
Cloud computing simple ppt
Cloud computing simple pptCloud computing simple ppt
Cloud computing simple pptAgarwaljay
 
Introduction of Cloud computing
Introduction of Cloud computingIntroduction of Cloud computing
Introduction of Cloud computingRkrishna Mishra
 

Viewers also liked (12)

NIC Virtualization on IBM Flex Systems
NIC Virtualization on IBM Flex SystemsNIC Virtualization on IBM Flex Systems
NIC Virtualization on IBM Flex Systems
 
Deploying IBM Flex System into a Cisco Network
Deploying IBM Flex System into a Cisco NetworkDeploying IBM Flex System into a Cisco Network
Deploying IBM Flex System into a Cisco Network
 
Lenovo midokura
Lenovo midokuraLenovo midokura
Lenovo midokura
 
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable SwitchesIBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
 
Ibm pure flex overview cust pr
Ibm pure flex overview cust prIbm pure flex overview cust pr
Ibm pure flex overview cust pr
 
IBM Systems of Interaction
IBM Systems of InteractionIBM Systems of Interaction
IBM Systems of Interaction
 
Microsoft Exchange 2013 architecture
Microsoft Exchange 2013 architectureMicrosoft Exchange 2013 architecture
Microsoft Exchange 2013 architecture
 
Cloud computing Basics
Cloud computing BasicsCloud computing Basics
Cloud computing Basics
 
Cloud computing ppt
Cloud computing pptCloud computing ppt
Cloud computing ppt
 
Cloud computing simple ppt
Cloud computing simple pptCloud computing simple ppt
Cloud computing simple ppt
 
Introduction of Cloud computing
Introduction of Cloud computingIntroduction of Cloud computing
Introduction of Cloud computing
 
cloud computing ppt
cloud computing pptcloud computing ppt
cloud computing ppt
 

Similar to IBM System Networking Easy Connect Mode

Presentation dc design for small and mid-size data center
Presentation   dc design for small and mid-size data centerPresentation   dc design for small and mid-size data center
Presentation dc design for small and mid-size data centerxKinAnx
 
VMworld 2015: Networking Virtual SAN's Backbone
VMworld 2015: Networking Virtual SAN's BackboneVMworld 2015: Networking Virtual SAN's Backbone
VMworld 2015: Networking Virtual SAN's BackboneVMworld
 
Vxlan deep dive session rev0.5 final
Vxlan deep dive session rev0.5   finalVxlan deep dive session rev0.5   final
Vxlan deep dive session rev0.5 finalKwonSun Bae
 
FlowER Erlang Openflow Controller
FlowER Erlang Openflow ControllerFlowER Erlang Openflow Controller
FlowER Erlang Openflow ControllerHolger Winkelmann
 
Flexible NFV WAN interconnections with Neutron BGP VPN
 Flexible NFV WAN interconnections with Neutron BGP VPN Flexible NFV WAN interconnections with Neutron BGP VPN
Flexible NFV WAN interconnections with Neutron BGP VPNThomas Morin
 
Logical_Routing_NSX_T_2.4.pptx.pptx
Logical_Routing_NSX_T_2.4.pptx.pptxLogical_Routing_NSX_T_2.4.pptx.pptx
Logical_Routing_NSX_T_2.4.pptx.pptxAnwarAnsari40
 
Vlan truks
Vlan truksVlan truks
Vlan truks1 2d
 
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...PROIDEA
 
Final exam ccna exploration 3 lan switching and wireless
Final exam ccna exploration 3 lan switching and wirelessFinal exam ccna exploration 3 lan switching and wireless
Final exam ccna exploration 3 lan switching and wirelesskratos2424
 
Network Design patters with Docker
Network Design patters with DockerNetwork Design patters with Docker
Network Design patters with DockerDaniel Finneran
 
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...VMworld
 

Similar to IBM System Networking Easy Connect Mode (20)

Presentation dc design for small and mid-size data center
Presentation   dc design for small and mid-size data centerPresentation   dc design for small and mid-size data center
Presentation dc design for small and mid-size data center
 
Dc fabric path
Dc fabric pathDc fabric path
Dc fabric path
 
Ccna 9
Ccna  9Ccna  9
Ccna 9
 
HP Virtual Connect technical fundamental101 v2.1
HP Virtual Connect technical fundamental101   v2.1HP Virtual Connect technical fundamental101   v2.1
HP Virtual Connect technical fundamental101 v2.1
 
Day 14.2 inter vlan
Day 14.2 inter vlanDay 14.2 inter vlan
Day 14.2 inter vlan
 
Icnd210 s02l01
Icnd210 s02l01Icnd210 s02l01
Icnd210 s02l01
 
VMworld 2015: Networking Virtual SAN's Backbone
VMworld 2015: Networking Virtual SAN's BackboneVMworld 2015: Networking Virtual SAN's Backbone
VMworld 2015: Networking Virtual SAN's Backbone
 
Vxlan deep dive session rev0.5 final
Vxlan deep dive session rev0.5   finalVxlan deep dive session rev0.5   final
Vxlan deep dive session rev0.5 final
 
FlowER Erlang Openflow Controller
FlowER Erlang Openflow ControllerFlowER Erlang Openflow Controller
FlowER Erlang Openflow Controller
 
Inf net2227 heath
Inf net2227 heathInf net2227 heath
Inf net2227 heath
 
Flexible NFV WAN interconnections with Neutron BGP VPN
 Flexible NFV WAN interconnections with Neutron BGP VPN Flexible NFV WAN interconnections with Neutron BGP VPN
Flexible NFV WAN interconnections with Neutron BGP VPN
 
Logical_Routing_NSX_T_2.4.pptx.pptx
Logical_Routing_NSX_T_2.4.pptx.pptxLogical_Routing_NSX_T_2.4.pptx.pptx
Logical_Routing_NSX_T_2.4.pptx.pptx
 
XS Boston 2008 XenLoop
XS Boston 2008 XenLoopXS Boston 2008 XenLoop
XS Boston 2008 XenLoop
 
Vlan truks
Vlan truksVlan truks
Vlan truks
 
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
 
Ies5000 usg
Ies5000 usgIes5000 usg
Ies5000 usg
 
Final exam ccna exploration 3 lan switching and wireless
Final exam ccna exploration 3 lan switching and wirelessFinal exam ccna exploration 3 lan switching and wireless
Final exam ccna exploration 3 lan switching and wireless
 
Network Design patters with Docker
Network Design patters with DockerNetwork Design patters with Docker
Network Design patters with Docker
 
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...
VMworld 2013: vSphere Networking and vCloud Networking Suite Best Practices a...
 
Xpress path vxlan_bgp_evpn_appricot2019-v2_
Xpress path vxlan_bgp_evpn_appricot2019-v2_Xpress path vxlan_bgp_evpn_appricot2019-v2_
Xpress path vxlan_bgp_evpn_appricot2019-v2_
 

More from IBM System Networking

More from IBM System Networking (14)

IBM Software Defined Networking for Virtual Environments (IBM SDN VE)
IBM Software Defined Networking for Virtual Environments (IBM SDN VE)IBM Software Defined Networking for Virtual Environments (IBM SDN VE)
IBM Software Defined Networking for Virtual Environments (IBM SDN VE)
 
Unified Fabric Architecture from BLADE Network Technologies
Unified Fabric Architecture from BLADE Network TechnologiesUnified Fabric Architecture from BLADE Network Technologies
Unified Fabric Architecture from BLADE Network Technologies
 
Green Networking With Blade
Green Networking With BladeGreen Networking With Blade
Green Networking With Blade
 
VMready Virtual Machine-aware Networking for HP
VMready Virtual Machine-aware Networking for HPVMready Virtual Machine-aware Networking for HP
VMready Virtual Machine-aware Networking for HP
 
10G Ethernet Overview & Use Cases
10G Ethernet Overview & Use Cases10G Ethernet Overview & Use Cases
10G Ethernet Overview & Use Cases
 
BLADE Company Overview
BLADE Company OverviewBLADE Company Overview
BLADE Company Overview
 
BLADE RackSwitch
BLADE RackSwitchBLADE RackSwitch
BLADE RackSwitch
 
VMready
VMreadyVMready
VMready
 
IBM BladeCenter Switches
IBM BladeCenter SwitchesIBM BladeCenter Switches
IBM BladeCenter Switches
 
HP BladeSystem Interconnects
HP BladeSystem InterconnectsHP BladeSystem Interconnects
HP BladeSystem Interconnects
 
BLADEHarmony Manager
BLADEHarmony ManagerBLADEHarmony Manager
BLADEHarmony Manager
 
BLADE Cloud Ready Network Architecture
BLADE Cloud Ready Network ArchitectureBLADE Cloud Ready Network Architecture
BLADE Cloud Ready Network Architecture
 
10G Ethernet Outlook for HPC
10G Ethernet Outlook for HPC10G Ethernet Outlook for HPC
10G Ethernet Outlook for HPC
 
Rackonomics and Network Virtualization with BLADE RackSwitch
Rackonomics and Network Virtualization with BLADE RackSwitchRackonomics and Network Virtualization with BLADE RackSwitch
Rackonomics and Network Virtualization with BLADE RackSwitch
 

Recently uploaded

Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptxLBM Solutions
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxOnBoard
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...HostedbyConfluent
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Alan Dix
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphNeo4j
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksSoftradix Technologies
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 

Recently uploaded (20)

Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Key Features Of Token Development (1).pptx
Key  Features Of Token  Development (1).pptxKey  Features Of Token  Development (1).pptx
Key Features Of Token Development (1).pptx
 
Maximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptxMaximizing Board Effectiveness 2024 Webinar.pptx
Maximizing Board Effectiveness 2024 Webinar.pptx
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
 
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge GraphSIEMENS: RAPUNZEL – A Tale About Knowledge Graph
SIEMENS: RAPUNZEL – A Tale About Knowledge Graph
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
Benefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other FrameworksBenefits Of Flutter Compared To Other Frameworks
Benefits Of Flutter Compared To Other Frameworks
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 

IBM System Networking Easy Connect Mode

  • 1. IBM Easy-Connect System Networking - Transparent Mode - Multi-chassis Mode (PureFlex ONLY) - Customer Examples EN/CN4093 and Virtual Fabric Switch Module Design and configuration by Scott Irwin & Igor Marty © 2013 IBM Corporation
  • 2. What is Easy-Connect • Clever pass-through = Simple I/O module connecting servers, storage and the Core network • Aggregation = Server ports aggregated together towards Core Network • No network integration = Seen as one big pipe with server traffic coming in and out. • No Spanning-Tree = No loops, no network integration • Similar to Cisco FEX – with one important exception, server to server traffic stays local to chassis. • Specific Networking features (Virtual Fabric Mode, VMready etc…) can still be activated on selected ports when/if needed. 2 © 2013 IBM Corporation
  • 3. Transparent Mode © 2013 IBM Corporation
  • 4. Easy-Connect - Transparent Mode Easy-Connect Transparent Mode • Looks like a “dumb” device to Nexus 5K/Edge Switch • No Spanning Tree Protocol (STP) – eliminates Network admin loop concerns • Provides traffic consolidation in the chassis to minimize ToR port utilization • Provides intra-chassis switching, even in Transparent Mode Client Benefits • Allows client to manage networking from the Edge/Nexus management system • Allows for intra-chassis switching for optimal performance (i.e. vMotion) • Allows for pay as you grow expandability in the chassis, both to the network and the compute nodes. Networking Infrastructure • VLAN’s are transparent when in “Transparent Mode” between the NIC and Edge Switch • Allows for pNIC or Switch Independent vNIC to be utilized • Note: Power Nodes supported in pNIC mode only • Allows for growth into “Virtual Fabric Mode” using multiple groups and uplinks • Allows for FCoE if ONLY using a single Uplink (FCoE currently not supported over PortChannel) How to set the I/O Switch into Transparent Mode • Set the uplinks as one logical unit via Static Port-Channel (note: VFSM support LACP when using vNIC Groups) • Turn on vNIC and configure all internal “ports” and external “port-channel” into vNIC “Group 1” • Turn on Spanning Tree BPDU Guard and Edge on the Edge/Nexus Switch for additional protection Note: If connecting to a Nexus 2k both BPDU Guard and Edge are already enabled by default and cannot be disabled. • Works with PureFlex Chassis EN/CN4093 and Virtual Fabric Switch Modules • If using FCoE over a single link simply enable CEE Globally (cee enable) © 2013 IBM Corporation
  • 5. Easy-Connect Configuration to convert from Switch Mode to Transparent Mode Configuration for the IBM VFSM and EN/CN4093 •ssh to each VFSM,EN/CN4093 •boot the VFSM,EN/CN4093 to use isCLI (Cisco-Like CLI) for a more familiar look • /boot/mode iscli • /boot/reset • /boot/prompt enable  enable if using FSM on PureFlex •Set the following commands to convert to “Transparent Mode” • ssh to each VFSM • enter into enable mode (e.g. enable) • enter into configuration terminal mode (e.g. config t) • type the following; (start with factory default configuration) vLAG Networking Infrastructure Switch Switch vPC “boot conf factory” ===========Begin Script =========== spanning-tree mode disable LACP interface port ext1-ext10 lacp key 1001 VFSM 1 VFSM 2 lacp mode active vnic enable vnic vnicgroup 1 vlan 4091 port int1-int14 adminkey 1001 Node enable failover exit Chassis write memory ===========End Script =========== © 2013 IBM Corporation
  • 6. Easy-Connect Configuration to convert from Switch Mode to Transparent Mode w/FCoE Configuration for the IBM VFSM and EN/CN4093 •ssh to each VFSM •boot the VFSM to use isCLI (Cisco-Like CLI) for a more familiar look • /boot/mode iscli • /boot/reset •Set the following commands to convert the VFSM to “Transparent Mode” • ssh to each VFSM • enter into enable mode (e.g. enable) • enter into configuration terminal mode (e.g. config t) • type the following; (start with factory default configuration) “boot conf factory” vLAG Networking Infrastructure Switch Switch vPC ===========Begin Script =========== spanning-tree mode disable interface port ext1-ext4 LACP lacp key 1001 lacp mode active VFSM 1 VFSM 2 vnic enable vnic vnicgroup 1 vlan 4091 port int1-int14 adminkey 1001 enable Node failover exit cee enable Chassis write memory ===========End Script =========== © 2013 IBM Corporation
  • 7. Multi-Chassis Mode © 2013 IBM Corporation
  • 8. Easy-Connect - Multi-chassis Mode Easy-Connect Multi-chassis Mode • Allows G8264 and EN/CN4093 look like a “dumb” device to Edge/Nexus Switches • No Spanning Tree Protocol (STP) Required – eliminates Network admin loop concerns • Provides traffic consolidation in the chassis to minimize ToR port utilization • Provides intra chassis switching, even in Easy-Connect Mode • Works with EN/CN4093 ONLY as VFSM does NOT support vLAG Client Benefits • Allows client to manage networking from the Edge/Nexus management system • Allows for intra/external chassis switching for optimal performance (i.e. vMotion) Networking Infrastructure • Allows for pay as you grow expandability in the chassis, both to the network and the compute nodes. • VLAN’s are transparent on both G8264 and EN/CN4093 when in “Easy-Connect Mode” between the NIC and Upstream AGG/Core Switch • Allows for pNIC or Switch Independent vNIC to be utilized • Allows for growth into Virtual Fabric Mode • Note: Power Nodes supported in pNIC mode only Use cases for Multi-Chassis Mode • Works with environments that require Active/Active NIC Teaming and or Bonding using 802.3ad and or Static EtherChannels on the NODE Ports • Works with both Intel and Power Nodes • ALL local Layer 2 Traffic, even if using different I/O Bays, will remain within the same enclosure with the use of the ISL Peer-Links between the EN/CN4093’s • Each Chassis appears to upstream Network as a single entity © 2013 IBM Corporation
  • 9. Easy-Connect What you end up with in Multi-chassis Mode with vLAG and vPC How-To: EN/CN4093 Easy-Connect Multi-chassis Mode Disable Global Spanning Tree Set all VFSM ports, both EXT Ports facing the Network (Top of Rack) and INT Ports, into tagpvid-ingress using VLAN 4091 as Switch Switch vLAG or vPC the PVID Enable TAGGING on the two EXT Ports being used as the vLAG Peer Link and set 4090 as the PVID adding VLAN 4091 as a LACP TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG ISL VLAN) EN/CN4093 EN/CN4093 vLAG Configure all required LACP PortChannels (Peer Link, EXT, and LACP INT Ports) Configure a dummy IP Address used by the MGT EXT Port Node vLAG Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2)) X or P Configure vLAG ISL, Health Check peer-ip, and all associated Chassis vLAG pairs NOTE: Turning on Spanning Tree BPDU Guard and Edge on the EDGE G8264 / Nexus 5K Switches can provide further protection © 2013 IBM Corporation
  • 10. Easy-Connect If using G8264’s in ToR also in Multi-Chassis Transparent Mode How-To: G8264 Easy-Connect Multi-chassis Mode vPC AGG/Core AGG/Core Disable Global Spanning Tree (not required (default is using Rapid PVST+ (i.e. PVRST))) LACP Set all G8264 ports, both uplink facing network and enclosure vLAG G8264-1 G8264-2 facing EN/CN4093’s, into tagpvid-ingress using VLAN 4091 as the PVID Enable TAGGING on the two ISL Ports being used as the vLAG LACP LACP Peer-Link and set 4090 as the PVID adding VLAN 4091 as a TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG vLAG EN/CN4093 EN/CN4093 ISL VLAN) LACP Configure all required LACP PortChannels (Peer Link, Uplinks, and EN/CN4093 facing ports) Node Configure a dummy IP Address used by the MGT Port vLAG X or P Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2)) NOTE: if using customers MGT Network set IP’s appropriately Chassis Configure vLAG ISL, Health Check peer-ip, and all associated vLAG pairs NOTE: Turning on Spanning Tree BPDU Guard and Edge on the EDGE G8264 / Nexus 5K Switches can provide further protection © 2013 IBM Corporation
  • 11. Customer requirements to implement Easy-Connect 1. If using FSM in same chassis – since the FSM is NOT capable of TAGGING (Cisco Trunking) customer MUST enable the Top-of-Rack Port “Native VLAN ID” with the VLAN that the FSM needs to be configured on. 2. ALL other OS’s (i.e. VMware, VIO, and even Bare Metal OS’s) within the PureFlex Chassis are required to TAG/Trunk VLAN’s. 3. If using multiple vNIC Groups for traffic either traffic separation and or if using Virtual Fabric Mode - each vNIC Group requires it’s own uplink/PortChannel or DUM (Dedicated Uplink Mode) 4. If Multi-Tenant security is a concern within the same PureFlex Chassis Easy-Connect may/may not be a good option. Why, because each vNIC Group is a single broadcast domain. 5. If IGMP Multicast Snooping is required Easy-Connect may not be a best option. Since Easy-Connect is VLAN Agnostic IGMP Snooping is not supported in any Q-n-Q Architecture. However, Multicast will still pass through the Easy Connect enabled Switches. 11 © 2013 IBM Corporation
  • 12. Easy Connect Customer Examples © 2013 IBM Corporation
  • 13. Easy-Connect EN/CN4093 Transparent Mode – Telecom Customer (Very Simple) Requirements included: •No Spanning Tree and or any other protocols seen by the network (Easy-Connect) •Connection into Nexus 2k (no vPC or vLAG requirement) •EN4093 is to be a total transparent device requiring no management by any group © 2013 IBM Corporation
  • 14. Easy-Connect EN/CN4093 Transparent Mode – State Government Requirements included: •Using LoM in Virtual Fabric Mode so bandwidth can be adjusted on the fly for each vNIC as required •Dedicated uplink vPC PortChannel from each EN4093 for each vNIC Group for separation of traffic •EN4093’s in Transparent Mode with minimal hands-on requirement (vNIC BW ONLY) © 2013 IBM Corporation
  • 15. Easy-Connect EN/CN4093 Storage Mode w/NIC Redundancy – Medical Center Requirements included: •Dedication and Separation of Fiber Channel and Ethernet from Each NODE and Enclosure •Total Hardware Redundancy including NIC and ASIC on every NODE (CN4054 Mezz) •Transparency on both Ethernet (Easy-Connect) and Fiber Channel (NPV) © 2013 IBM Corporation
  • 16. Backup Slides © 2013 IBM Corporation
  • 17. Four Scalable switches enable high speed connectivity – Ethernet (FCoE, iSCSI), Fibre Channel and InfiniBand Four high performance Scalable Switch Modules 3 2 4 1 17 17 © 2013 IBM Corporation
  • 18. Robust connectivity: Switch, asic and adapter level redundancy Redundant pair asic level redundancy Redundant pair EN4093 (base) EN4093 (base) EN4093 (base) EN4093 (base) asic 1 asic 2 CN4054 EN4093 (Upgrade 1) EN4093 (Upgrade 1) EN4093 (Upgrade 1) EN4093 (Upgrade 1) asic 1 asic 2 CN4054 1 3 2 4 Adapter level redundancy © 2013 IBM Corporation

Editor's Notes

  1. March 20, 2013 BLADE Network Technologies, An IBM Company
  2. March 20, 2013 BLADE Network Technologies, An IBM Company
  3. March 20, 2013 BLADE Network Technologies, An IBM Company
  4. EN/CN4093 configuration to support Multi-Chassis Mode (OS Version 7.5.1) ssh to each EN/CN4093 boot to isCLI (Cisco-Like CLI) /boot/mode iscli /boot/reset Set the following commands to convert the EN/CN4093 into “Multi-chassis Mode” ssh to each EN/CN4093 enter into enable mode (e.g. enable) enter into configuration terminal mode (e.g. config t) type the following; (note: the IP Address of the health check “IP 127” Address will be different on both switch, everything else should remain the same) ===========Begin Script =========== spanning-tree mode disable interface port ext9,ext10  ISL vLAG Peer-Link Ports pvid 4090 tagging lacp key 1001 lacp mode active vlan 4090 enable name Peer-Link vlan 4091  Note: if using Power-Nodes also and want in separate domain (including uplinks (a MUST)) use VLAN 4092 enable name Intel-Nodes member int1-int14,ext1-ext4,ext9,ext10 interface port inta1-inta14,ext1-ext4 tagpvid-ingress interface port ext1-ext4  uplink ports to AGG/Core lacp key 4091  use SAME key on both VFSM INTEL Uplinks (4091) lacp mode active interface port inat1  INTa1 on both Switches will be in same PortChannel using vLAG (lacp key MUST match) lacp key 101 lacp mode active interface port inat2 lacp key 102 lacp mode active interface ip 127  IP 127 is dedicated to the MGT Port used for vLAG health check ip address 1.1.1.1 enable vlag ena vlag isl peer-ip 1.1.1.2  other switch will use 1.1.1.1 vlag isl vlan 4090 vlag isl adminkey 1001 vlag tier-id 10  each pair of switches connecting to each other should be a different Tier-ID vlag adminkey 4091 enable vlag adminkey 101 enable vlag adminkey 102 enable  repeat for each Server using 802.3ad / LACP write memory ===========End Script ===========
  5. G8264 configuration to support Multi-Chassis Mode (OS Version 7.5.1) ssh to each G8264 Note: G8264 uses isCLI by default Set the following commands to convert the G8264 into “Multi-chassis Mode” ssh to each G8264 enter into enable mode (e.g. enable) enter into configuration terminal mode (e.g. config t) type the following; (note: the IP Address of the health check “IP 128” Address will be different on both switch, everything else should remain the same) ===========Begin Script =========== spanning-tree mode disable  Optional interface port 1,5  2x 40Gb ISL (e.g. between G8264 ’s) tagging pvid 4090 lacp key 4090 lacp mode active vlan 4090 enable name Peer-Link vlan 4091 enable name “Transparent-Ports” interface port 17-64  Uplinks and EN/CN4093 facing Ports ONLY tagpvid-ingress interface port 17,18  uplink ports to AGG/Core lacp key 1001 lacp mode active interface port 19,20  Ports facing first PureFlex enclosure lacp key 1920 lacp mode active interface port 21,22 lacp key 2122  Ports facing second PureFlex enclosure lacp mode active vlag ena vlag isl adminkey 4090 vlag tier-id 1 vlag adminkey 1001 ena  Uplink PortChannel to AGG/Core vlag adminkey 1920 ena vlag adminkey 2122 ena  repeat for each Port-Channel to each EN/CN4093 write memory ===========End Script ===========
  6. March 20, 2013 BLADE Network Technologies, An IBM Company
  7. March 20, 2013 BLADE Network Technologies, An IBM Company