1. FG-1625F
GLASSBREAK DETECTOR
The new FG-1625F Glassbreak Detector uses the latest technology to provide faster response and increased false alarm
immunity. The FG-1625F is specifically designed to allow fast, easy installation, while the adjustable sensitivity settings can
compensate for the acoustics of any room. Optimum operation can be quickly verified using the FG-701 Glassbreak Simulator.
The FG-1625F was designed to adequately cover all sizes of single gang electrical boxes. Flush mount installations are now
easier and better looking than ever.
FEATURES
• FlexCore™ Signal Processor • Selectable Sensitivity • Multiple Domain Signal Analysis
The FlexCore™ Signal Processor Two DIP switches on the FG-1625F The FG-1625F performs Multiple
is an Application-Specific Integrated make it easy to set the sensitivity to Domain Signal Analysis in which
Circuit (ASIC), which processes match the acoustics of the room. time, frequency and amplitude
sound data in parallel rather than Four different sensitivity levels are characteristics are evaluated for signal
sequentially; for faster, more available, ranging from very low to qualification. This enables the detector
accurate detection decisions. The high. The range can then be verified to accurately discriminate false alarms
combination of proven FlexGuard® remotely with the FlexGuard FG-701 from true glassbreak events.
performance with the speed of Glassbreak Simulator.
• Enclosed PC Board
FlexCore processing provides
• Mount the Detector Anywhere The PCB is protected from potential
unmatched false alarm immunity
Mounts on any wall or on the ceiling, damage during installation.
without compromising detection.
with no minimum range and a
• Patented Remote Test Mode
• Easy Installation and Setup maximum range of 25' (7.6m) to the
The Patented Remote Test Mode
Honeywell’s patented technology glass. The FG-1625F fits a standard
can enable or disable the indicator
allows remote activation of single gang electrical box; while the
LEDs using the FG-701 Glassbreak
Test Mode (with simulator). FG-1525FD version is specifically
Simulator. The unit automatically
The FG-1625F has 45° terminal designed for double gang boxes.
resets from Test Mode in five minutes.
blocks for easier wiring. A hand-clap • Covers All Glass Types
• Mounting Locations
feature verifies that the detector is The FG-1625F works on all glass types,
The FG-1625F can be mounted on
functioning. including plate, tempered, laminated,
the ceiling, opposite wall, adjoining
wired, film-coated and sealed insulating.
wall, or the same wall as the glass.