1. FG-1625R/1625RT
GLASSBREAK DETECTOR
The new FG-1625R Glassbreak Detector uses the latest easy installation, while the adjustable sensitivity settings can
technology to provide faster response and increased false alarm compensate for the acoustics of any room. Optimum operation
immunity. The FG-1625R is specifically designed to allow fast, can be quickly verified using the FG-701 Glassbreak Simulator.
FEATURES
• FlexCore™ Signal Processor • Selectable Sensitivity • Multiple Domain Signal Analysis
The FlexCore Signal Processor is Two dip switches on the FG-1625R The FG-1625R performs Multiple
an Application Specific Integrated make it easy to set the sensitivity to Domain Signal Analysis in which time,
Circuit (ASIC), which processes match the acoustics of room. Four frequency and amplitude characteristics
sound data in parallel rather than different sensitivity levels are available, are evaluated for signal qualification.
sequentially for faster, more accurate ranging from very low to high. The This enables the detector to accurately
detection decisions. range can then be verified remotely discriminate false alarms from true
The combination of proven with the FlexGuard FG-701 glassbreak events.
FlexGuard performance with the
®
Glassbreak Simulator.
• Enclosed PC Board
speed of FlexCore processing provides
• Mount the Detector Anywhere The PCB is protected from potential
unmatched false alarm immunity
Mounts on any wall, in the window damage during installation.
without compromising detection.
frame, or on the ceiling, with no
• Patented Remote Test Mode
• Easy Installation and Setup minimum range and a maximum
The Patented Remote Test Mode can
Honeywell’s patented technology range of 25’ (7.6m) to the glass.
enable or disable the indicator LEDs
allows remote activation of Test
• Covers All Glass Types remotely using the FG-701 Glassbreak
Mode (with simulator). The FG-1625R
The FG-1625R works on all glass Simulator. The detector automatically
has a centered wire entry hole, 45º
types, including plate, tempered, resets from Test Mode in five minutes.
terminal blocks and EOL terminals.
laminated, wired, film-coated,
A hand-clap feature verifies the • Mounting Locations
sealed insulating glass.
detector is functioning. The FG-1625R can be mounted on
the ceiling, opposite wall, adjoining
wall, or the same wall as the glass.