1. N7131V5 5/04 Rev. A Specifications
ADEMCO 5802MN Unit Dimensions:
2.4” (61mm) x 1.5” (38mm) x 0.5” (13mm)
SUPERVISED MINIATURE LED: Lights when unit transmits.
TRANSMITTER Battery: 3V Duracell DL 2032 or Newsum, Maxell, Panasonic,
INSTALLATION AND SETUP GUIDE Renata, or Sanyo CR2032
In UL installations: 3V Newsum, Maxell, or
The ADEMCO 5802MN is a wireless transmitter that may Renata CR2032 only
be worn on a belt (belt holder supplied) or around the 3V
LITHIUM Battery access is via a quarter
neck (necklace supplied). Pressing the button on the RENATA
CR2032
turn (use a nickel to open
transmitter sends a signal to the control receiver. The Battery case back). Excessive turning
Remove
5802MN is intended for use only with wireless alarm battery Slide may result in damaging the
cover battery
systems that support 5800 Series devices. L
L under cover.
L Lpin
The transmitter is supervised, i.e., every hour it Note battery polarity:
L
L
L
L
automatically sends a message to the control receiver + POS end must face up
L
L
5820MN
(visible when installed).
that includes battery status information. Back of 5802MN
This transmitter can be programmed as any zone type REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
response (e.g., Emergency Panics, Relay Action, etc.). RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED FOR
Battery Replacement WARRANTY INFORMATION AND FOR DETAILS REGARDING THE
LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
The 5802MN is powered by a long-life Lithium battery that
FCC STATEMENT
may be replaced when a low battery is eventually FCC ID: CFS8DL5802MN CANADA: 1748101382 5 3
indicated by the control unit. This device complies with Part 15 of the FCC Rules. Operation is
NOTE: Although the 5802MN is water-resistant, please subject to the following two conditions:
do not submerge. (1) This device may not cause harmful interference
Programming the Serial Number (2) This device must accept any interference received, including
interference that may cause undesired operation.
The 5802MN has a unique identification code (serial
UL US Listings: HOUSEHOLD BURGLARY WARNING SYSTEM
number) permanently assigned during manufacture. CONTROL UNIT ACCESSORY UL Canadian Listings:
You must “enroll” the transmitter’s serial number and loop HOUSEHOLD BURGLARY WARNING SYSTEM CONTROL UNIT
number during system programming. The 5802MN may ACCESSORY ALSO LISTED FOR USE AS A SIGNAL APPLIANCE,
be defined as Input Type “RF” (supervised RF, for an MISCELLANEOUS CERTIFIED FOR CANADA.
hourly check-in; do not take out of range) or “UR”
(Unsupervised RF). Its loop number is “1.” See the control
unit’s Installation Instructions for further details regarding
programming.
When installation is complete, verify operation from
ÊN7131V5WŠ
N7131V5 5/04 Rev. A
desired location(s).