GC-6890 Gas Chromatograph can be used to measure residual solvent for packaging industry or other related industries and detecting institutions. It is the best choice for determination of residual solvent, smell analysis, and solvent purity. 
Professional Technology 
 GC-6890 comes with characteristics of profession, reliability, precision and competitive price, which is equipped with hydrogen flame 
ionization detector (FID). 
 The instrument is controlled by micro-computer and integrated circuit, with big display screen. Functions of keyboard inputting parameters, power failure protection and file storage or inquiry provide a comfortable operating environment. 
 Detectors with control elements utilize plug-and-play (PNP) extension control mode 
 Constant temperature or temperature program can be achieved in this instrument. And preset of chromatographic column chamber could be reached through automatic open-close of its flexible back door. 
 Gas tube is flexible and reliable which extendable for different feeding gases or tests. 
 Sampler system is equipped with packed column, capillary column and other devices to transfer test gases into the system. 
 Instrument is designed with functions of lower pressure for carrier gas tube and protection gas transmission interrupt. 
 High temperature protection is applied so that instrument could stop working and alarm when the temperature of any gas tube exceeds the preset (set at 20°C). 
 1500mV wide range of response signal, with good consistency, could meet analysis requirements of high purity samples. 
 Good performance of chromatographic column box makes it possible to achieve the operation at room temperature+3°C, even when the temperatures of detection and vaporizing chambers are as high 200°C. Instrument comes with good repeatability of temperature program to ensure the retention time consistency of sample components. 
 Special designed operating software and hardware could automatically monitor the whole process, which creates a safe test environment for users. 
 Instrument could be easily connected with chromatography data converter, system or other graphing devices. 
 Professional chromatographic data system provides powerful and intelligent process function to automatically identify the names and quantities (mg/m2) of residual solvents tested samples in accordance with reference data. Instrument is also available for the detection of solvent purity. 
Test Principle 
A gas chromatograph is a separating or analytical instrument for mixture containing various components. It takes the inert gas as mobile phase, and utilizes chromatographic column separation technology. The mixture 
GC-6890 Gas Chromatograph 
PARAM®
Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
injected into the instrument follows the carrier gas into a separation tube known as “column”. Because of different distribution coefficients in the column, distinct components will display different mobile speeds. After certain column, the analyzed components will leave column consecutively into detector where corresponding electrical signals will be generated and taken to chromatography data system. The detection analysis of tested mixture is accomplished. 
Applications 
Basic Applications 
Residual Solvent 
For the residual solvent analysis test of plastic films, paper-plastic composite films for food and drugs, , cigarette packaging materials 
Purity Analysis 
For the purity analysis test of various solvents used in packaging and printing materials 
Extended Applications 
(Special Accessories or Customization Required) 
Chlorethylene Analysis 
For the content analysis of Chlorethylene 
Automatic Sampler 
Perform the test automatically to minimize errors caused by human factors 
Technical Specifications 
Temperature of Chromatographic Column Chamber 
Temperature Range 
Room Temperature +3°C~ 399°C 
Accuracy 
Better than ±0.1°C 
Temperature Gradient 
Effective range of column is less than 2% 
Temperature Deviation 
Deviation between preset temperature and display temperature is less than 1°C 
Temperature Deviation 
Deviation between preset temperature and actual temperature is less than 2% 
Orders of Temperature Program 
4 orders 
Rate of Temperature 
0.1 ~ 30°C/min 
Temperature Range of Linear Temperature Program 
Lower than 150 °C while 30°per minute 
Lower than 300 °C while 15°per minute 
Lower than 350 °C while 10°per minute 
Control Time from Primary to Terminal Temperature 
0 ~ 600 min 
Repeatability of Temperature Program 
Less than 2% 
Temperature 
Decreasing Speed 
Less than 15 min from 300°C to 50°C 
Vaporizing Chamber 
Temperature Accuracy 
±0.1°C(room temperature +15°C ~ 200°C) 
±0.2°C 
while temperature is higher than 200°Test Chamber 
Temperature Accuracy 
±0.1°C(room temperature +15°C ~ 200°C) 
±0.2°C 
while temperature is higher than 200°Flame Ionization Detector 
Testing Limit 
Less than 2 x 10-11g/s (Benzene)
Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
(FID) 
Noise 
Less than 0.025 mV 
Drift 
Less than 0.15 mV/h 
Mainframe 
Power Supply 
AC 220V 50Hz 
Instrument Dimension 
510 mm (L) x 490 mm (W) x 480 mm (H) 
Net Weight 
45 kg 
Configurations 
Standard Configurations 
Gas Chromatograph Mainframe, Hydrogen Flame Ionization Detector, Capillary Analytical Column, and Chromatography Data System 
Note 
1. Customers will need to prepare for gas supply (high purity nitrogen, hydrogen, dry and oil-free air), analytical reagent (added in the process of printing or composition), headspace bottle, 1mL glass syringe (with 5# needle), and computer. 
2. Chromatographic analysis laboratory of Labthink will build test methods and provide operation training for free. 
Please Note: Labthink is always dedicated to the innovation and improvement of product performance function. Therefore, technical specifications are subject to change without further notice. Please visit our website at www.labthinkinternational.com.cn for the latest updates. Labthink reserves the rights of final interpretation and revision.

More Related Content

What's hot

UV300 online water analyser tethys datasheet
UV300 online water analyser tethys datasheetUV300 online water analyser tethys datasheet
UV300 online water analyser tethys datasheetENVIMART
 
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensor
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensorCAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensor
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensorENVIMART
 
Vapour pressure-model-1354 atac
Vapour pressure-model-1354 atacVapour pressure-model-1354 atac
Vapour pressure-model-1354 atacEuropean Tech Serv
 
Energy tech 301 codel datasheet-dust monitor
Energy tech 301 codel datasheet-dust monitorEnergy tech 301 codel datasheet-dust monitor
Energy tech 301 codel datasheet-dust monitorENVIMART
 
Egas datasheet(1)
Egas datasheet(1)Egas datasheet(1)
Egas datasheet(1)a1-cbiss
 
Toc analyser, microprocessor controlled
Toc analyser, microprocessor controlledToc analyser, microprocessor controlled
Toc analyser, microprocessor controlledhydrologyproject0
 
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsCondumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsENVIMART
 
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersEasy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersENVIMART
 
Ec91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen AnalyserEc91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen AnalyserSystechIllinois
 
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitorDCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitorENVIMART
 
UV300-5D online analyser for drinking water-tethys datasheet
UV300-5D online analyser for drinking water-tethys datasheetUV300-5D online analyser for drinking water-tethys datasheet
UV300-5D online analyser for drinking water-tethys datasheetENVIMART
 
Thermal analysis
Thermal analysisThermal analysis
Thermal analysislabmen1998
 
GCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetGCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetENVIMART
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheeta1-cbiss
 

What's hot (16)

UV300 online water analyser tethys datasheet
UV300 online water analyser tethys datasheetUV300 online water analyser tethys datasheet
UV300 online water analyser tethys datasheet
 
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensor
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensorCAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensor
CAS74 stip scan cam74-cas74-endress+hauser datasheet-BOD sensor
 
Vapour pressure-model-1354 atac
Vapour pressure-model-1354 atacVapour pressure-model-1354 atac
Vapour pressure-model-1354 atac
 
Energy tech 301 codel datasheet-dust monitor
Energy tech 301 codel datasheet-dust monitorEnergy tech 301 codel datasheet-dust monitor
Energy tech 301 codel datasheet-dust monitor
 
novasulf hg100 h2s analyser
novasulf hg100 h2s analysernovasulf hg100 h2s analyser
novasulf hg100 h2s analyser
 
Egas datasheet(1)
Egas datasheet(1)Egas datasheet(1)
Egas datasheet(1)
 
Toc analyser, microprocessor controlled
Toc analyser, microprocessor controlledToc analyser, microprocessor controlled
Toc analyser, microprocessor controlled
 
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensorsCondumax CLS15_15D-endress+hauser datasheet-conductivity sensors
Condumax CLS15_15D-endress+hauser datasheet-conductivity sensors
 
Novasulf HG400 H2S analyser
Novasulf HG400 H2S analyserNovasulf HG400 H2S analyser
Novasulf HG400 H2S analyser
 
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzersEasy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
 
Ec91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen AnalyserEc91 Intrinsically Safe Oxygen Analyser
Ec91 Intrinsically Safe Oxygen Analyser
 
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitorDCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
 
UV300-5D online analyser for drinking water-tethys datasheet
UV300-5D online analyser for drinking water-tethys datasheetUV300-5D online analyser for drinking water-tethys datasheet
UV300-5D online analyser for drinking water-tethys datasheet
 
Thermal analysis
Thermal analysisThermal analysis
Thermal analysis
 
GCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheetGCEM4000 insitu gas analyser codel datasheet
GCEM4000 insitu gas analyser codel datasheet
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheet
 

Similar to GC-6890-Gas Chromatograph for Cigarette Packaging Materials

Gc 7800-gas-chromatograph
Gc 7800-gas-chromatographGc 7800-gas-chromatograph
Gc 7800-gas-chromatographEmilywu12
 
GC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosamplerGC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosamplerEmilywu12
 
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-LabthinkG2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-LabthinkLabthink International,Inc.
 
G2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzerG2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzerEmilywu12
 
Gas Chromatography.pdf
Gas Chromatography.pdfGas Chromatography.pdf
Gas Chromatography.pdfalizalabtronuk
 
Oxygen transmittance tester
Oxygen transmittance testerOxygen transmittance tester
Oxygen transmittance testerlabmen1998
 
160729 ama instruments_datasheet_gc5000
160729 ama instruments_datasheet_gc5000160729 ama instruments_datasheet_gc5000
160729 ama instruments_datasheet_gc5000European Tech Serv
 
Plastic testing instruments
Plastic testing instrumentsPlastic testing instruments
Plastic testing instrumentsPacorr Testing
 
BTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragmsBTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragmsLabthink International,Inc.
 
BTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-TesterBTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-TesterEmilywu12
 
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.Acmas Technologies Pvt. Ltd.
 
8000 Oxygen Permeation Analysers
8000 Oxygen Permeation Analysers8000 Oxygen Permeation Analysers
8000 Oxygen Permeation AnalysersSystechIllinois
 
Weiber multi functional infra red moisture analyzer
Weiber multi functional infra red moisture analyzerWeiber multi functional infra red moisture analyzer
Weiber multi functional infra red moisture analyzerAcmas Technologies Pvt. Ltd.
 

Similar to GC-6890-Gas Chromatograph for Cigarette Packaging Materials (20)

Gc 7800-gas-chromatograph
Gc 7800-gas-chromatographGc 7800-gas-chromatograph
Gc 7800-gas-chromatograph
 
GC 7800-Gas-Chromatograph-with-Autosampler
GC 7800-Gas-Chromatograph-with-AutosamplerGC 7800-Gas-Chromatograph-with-Autosampler
GC 7800-Gas-Chromatograph-with-Autosampler
 
GC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosamplerGC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosampler
 
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-LabthinkG2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
 
G2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzerG2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzer
 
Mixed Gas Permeability Analyzer
Mixed Gas Permeability AnalyzerMixed Gas Permeability Analyzer
Mixed Gas Permeability Analyzer
 
G2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability AnalyzerG2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability Analyzer
 
Gas-Chromatography.pdf
Gas-Chromatography.pdfGas-Chromatography.pdf
Gas-Chromatography.pdf
 
Gas Chromatography.pdf
Gas Chromatography.pdfGas Chromatography.pdf
Gas Chromatography.pdf
 
Oxygen transmittance tester
Oxygen transmittance testerOxygen transmittance tester
Oxygen transmittance tester
 
160729 ama instruments_datasheet_gc5000
160729 ama instruments_datasheet_gc5000160729 ama instruments_datasheet_gc5000
160729 ama instruments_datasheet_gc5000
 
OX2 230-Oxygen-Transmission-rate-Test-System
OX2 230-Oxygen-Transmission-rate-Test-SystemOX2 230-Oxygen-Transmission-rate-Test-System
OX2 230-Oxygen-Transmission-rate-Test-System
 
Plastic testing instruments
Plastic testing instrumentsPlastic testing instruments
Plastic testing instruments
 
BTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragmsBTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragms
 
BTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-TesterBTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-Tester
 
BTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-TesterBTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-Tester
 
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.
Automatic Infrared Moisture Analyzer Meter by ACMAS Technologies Pvt Ltd.
 
8000 Oxygen Permeation Analysers
8000 Oxygen Permeation Analysers8000 Oxygen Permeation Analysers
8000 Oxygen Permeation Analysers
 
Weiber multi functional infra red moisture analyzer
Weiber multi functional infra red moisture analyzerWeiber multi functional infra red moisture analyzer
Weiber multi functional infra red moisture analyzer
 
HGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-AnalyzerHGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-Analyzer
 

Recently uploaded

NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...
NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...
NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...Amil Baba Dawood bangali
 
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理kywwoyk
 
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...Amil baba
 
1. WIX 2 PowerPoint for Work Experience.pptx
1. WIX 2 PowerPoint for Work Experience.pptx1. WIX 2 PowerPoint for Work Experience.pptx
1. WIX 2 PowerPoint for Work Experience.pptxlouise569794
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理eemet
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理kywwoyk
 
F5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptxF5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptxArjunJain44
 
Memory compiler tutorial – TSMC 40nm technology
Memory compiler tutorial – TSMC 40nm technologyMemory compiler tutorial – TSMC 40nm technology
Memory compiler tutorial – TSMC 40nm technologyAhmed Abdelazeem
 

Recently uploaded (8)

NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...
NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...
NO1 Pandit Black magic/kala jadu,manpasand shadi in lahore,karachi rawalpindi...
 
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
 
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
 
1. WIX 2 PowerPoint for Work Experience.pptx
1. WIX 2 PowerPoint for Work Experience.pptx1. WIX 2 PowerPoint for Work Experience.pptx
1. WIX 2 PowerPoint for Work Experience.pptx
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
 
F5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptxF5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptx
 
Memory compiler tutorial – TSMC 40nm technology
Memory compiler tutorial – TSMC 40nm technologyMemory compiler tutorial – TSMC 40nm technology
Memory compiler tutorial – TSMC 40nm technology
 

GC-6890-Gas Chromatograph for Cigarette Packaging Materials

  • 1. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn GC-6890 Gas Chromatograph can be used to measure residual solvent for packaging industry or other related industries and detecting institutions. It is the best choice for determination of residual solvent, smell analysis, and solvent purity. Professional Technology  GC-6890 comes with characteristics of profession, reliability, precision and competitive price, which is equipped with hydrogen flame ionization detector (FID).  The instrument is controlled by micro-computer and integrated circuit, with big display screen. Functions of keyboard inputting parameters, power failure protection and file storage or inquiry provide a comfortable operating environment.  Detectors with control elements utilize plug-and-play (PNP) extension control mode  Constant temperature or temperature program can be achieved in this instrument. And preset of chromatographic column chamber could be reached through automatic open-close of its flexible back door.  Gas tube is flexible and reliable which extendable for different feeding gases or tests.  Sampler system is equipped with packed column, capillary column and other devices to transfer test gases into the system.  Instrument is designed with functions of lower pressure for carrier gas tube and protection gas transmission interrupt.  High temperature protection is applied so that instrument could stop working and alarm when the temperature of any gas tube exceeds the preset (set at 20°C).  1500mV wide range of response signal, with good consistency, could meet analysis requirements of high purity samples.  Good performance of chromatographic column box makes it possible to achieve the operation at room temperature+3°C, even when the temperatures of detection and vaporizing chambers are as high 200°C. Instrument comes with good repeatability of temperature program to ensure the retention time consistency of sample components.  Special designed operating software and hardware could automatically monitor the whole process, which creates a safe test environment for users.  Instrument could be easily connected with chromatography data converter, system or other graphing devices.  Professional chromatographic data system provides powerful and intelligent process function to automatically identify the names and quantities (mg/m2) of residual solvents tested samples in accordance with reference data. Instrument is also available for the detection of solvent purity. Test Principle A gas chromatograph is a separating or analytical instrument for mixture containing various components. It takes the inert gas as mobile phase, and utilizes chromatographic column separation technology. The mixture GC-6890 Gas Chromatograph PARAM®
  • 2. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn injected into the instrument follows the carrier gas into a separation tube known as “column”. Because of different distribution coefficients in the column, distinct components will display different mobile speeds. After certain column, the analyzed components will leave column consecutively into detector where corresponding electrical signals will be generated and taken to chromatography data system. The detection analysis of tested mixture is accomplished. Applications Basic Applications Residual Solvent For the residual solvent analysis test of plastic films, paper-plastic composite films for food and drugs, , cigarette packaging materials Purity Analysis For the purity analysis test of various solvents used in packaging and printing materials Extended Applications (Special Accessories or Customization Required) Chlorethylene Analysis For the content analysis of Chlorethylene Automatic Sampler Perform the test automatically to minimize errors caused by human factors Technical Specifications Temperature of Chromatographic Column Chamber Temperature Range Room Temperature +3°C~ 399°C Accuracy Better than ±0.1°C Temperature Gradient Effective range of column is less than 2% Temperature Deviation Deviation between preset temperature and display temperature is less than 1°C Temperature Deviation Deviation between preset temperature and actual temperature is less than 2% Orders of Temperature Program 4 orders Rate of Temperature 0.1 ~ 30°C/min Temperature Range of Linear Temperature Program Lower than 150 °C while 30°per minute Lower than 300 °C while 15°per minute Lower than 350 °C while 10°per minute Control Time from Primary to Terminal Temperature 0 ~ 600 min Repeatability of Temperature Program Less than 2% Temperature Decreasing Speed Less than 15 min from 300°C to 50°C Vaporizing Chamber Temperature Accuracy ±0.1°C(room temperature +15°C ~ 200°C) ±0.2°C while temperature is higher than 200°Test Chamber Temperature Accuracy ±0.1°C(room temperature +15°C ~ 200°C) ±0.2°C while temperature is higher than 200°Flame Ionization Detector Testing Limit Less than 2 x 10-11g/s (Benzene)
  • 3. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn (FID) Noise Less than 0.025 mV Drift Less than 0.15 mV/h Mainframe Power Supply AC 220V 50Hz Instrument Dimension 510 mm (L) x 490 mm (W) x 480 mm (H) Net Weight 45 kg Configurations Standard Configurations Gas Chromatograph Mainframe, Hydrogen Flame Ionization Detector, Capillary Analytical Column, and Chromatography Data System Note 1. Customers will need to prepare for gas supply (high purity nitrogen, hydrogen, dry and oil-free air), analytical reagent (added in the process of printing or composition), headspace bottle, 1mL glass syringe (with 5# needle), and computer. 2. Chromatographic analysis laboratory of Labthink will build test methods and provide operation training for free. Please Note: Labthink is always dedicated to the innovation and improvement of product performance function. Therefore, technical specifications are subject to change without further notice. Please visit our website at www.labthinkinternational.com.cn for the latest updates. Labthink reserves the rights of final interpretation and revision.