BTY-B2P is based on the differential pressure method, and is professionally applicable to the determination of gas permeability of battery diaphragms, breathable films and other relative polymer products.
G2/131 is based on differential pressure method and applicable to the determination of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of barrier materials and packages at different temperatures.
G2/132 is based on the differential pressure method and professionally applicable to the determination of gas permeability of film specimens. It is equipped with three diffusion cells.
W3/031 is professionally applicable to the water vapor transmission rate test of film specimens. It is equipped with three individual test dishes and the testing process is completely automatic and conforms to international standards.
VAC-V3 is designed for the measurement of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, sheets, foils, etc.
VAC-V2 can be used to measure gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, sheets, foils, etc.
OX2/230 is professionally designed for the determination of oxygen transmission rate of film and package specimens. This instrument is applicable to various materials with high, medium and low oxygen permeability.
W3/030 is based on the cup method and designed for water vapor transmission rate measurement of plastic films, laminated films, sheets as well as various materials used in medical and construction industries
G2/110 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of sole gas or mixed gases in separation membranes.
G2/131 is based on differential pressure method and applicable to the determination of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of barrier materials and packages at different temperatures.
G2/132 is based on the differential pressure method and professionally applicable to the determination of gas permeability of film specimens. It is equipped with three diffusion cells.
W3/031 is professionally applicable to the water vapor transmission rate test of film specimens. It is equipped with three individual test dishes and the testing process is completely automatic and conforms to international standards.
VAC-V3 is designed for the measurement of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, sheets, foils, etc.
VAC-V2 can be used to measure gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, sheets, foils, etc.
OX2/230 is professionally designed for the determination of oxygen transmission rate of film and package specimens. This instrument is applicable to various materials with high, medium and low oxygen permeability.
W3/030 is based on the cup method and designed for water vapor transmission rate measurement of plastic films, laminated films, sheets as well as various materials used in medical and construction industries
G2/110 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of sole gas or mixed gases in separation membranes.
VAC-V1 is applicable to the determination of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, sheeting, foils and finished packages, etc.
W3/330 system is based on the electrolytic sensor method to measure water vapor transmission rate of film and package specimens. It has three independent testing cells and can be easily connected with 9 satellite systems.
W3/0120 is based on cup method to measure water vapor transmission rate of plastic films, foils and finished packages. It has 12 independent testing cells and conforms to ASTM, ISO international standards.
TSY-W3 is professionally applicable to determination of water vapor permeability of plastic films, high barrier materials, back-sheets, sheeting, aluminum foils, waterproof materials, and other materials used in sanitary and medical industry.
W3/060 is based on cup method to measure water vapor transmission rate of plastic films, foils and finished packages. It has Six independent testing cells and can be easily connected with 9 satellite systems.
BTY-B2P is based on the differential pressure method, and is professionally applicable to the determination of gas permeability of battery diaphragms, breathable films and other relative polymer products.
G2/130 is based on differential pressure method, and can be used to measure gas transmission rate of flexible containers, including various bottles of carbonated drinks, juice, tea and packages of edible oil, dairy products, washing supplies and metal containers.
ERT-01 Evaporation Residue Constant Weight Tester is professionally designed for the precisely quantitative determination of dissolved substances of table wares, containers, packaging films, cans, tubes and other food-use equipments in different soaking solutions.
BLD-200N Auto Stripping Tester can be used for peeling, stripping and other performance tests of adhesives, adhesive tapes, pressure sensitive tapes, medical adhesive bandage, protective films, release paper, laminated films, leatheroid, woven bags, films and paper.
BMC-B1 is designed for determination of mechanical properties of packaging materials such as plastic films, laminates and paper by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.
CHY-CA is based on mechanical contacting method and applicable to thickness test for plastic films, sheets,paper, foils and other materials within specified range. CHY-CA has auto sampling mechanism.
BLJ-02 is designed for the determination of ink fastness of plastic films and glass paper decorating printed materials that utilize the intaglio printing technique. It also could be used to test adhesion condition of surface layers formed by the technique of vacuum coating, surface coating and lamination.
la toma de decisiones, lo que diferencia unos jugadores de otros. Exposición realizada en la Escuela de Directores Técnicos de Fútbol de la Federación Peruana de Fútbol en enero de 2014. Y durante el I Torneo de la Amistad del Sur, celebrado en Tacna (Perú) en Agosto de 2014. Iván Chaves
CHY-CB is based on contacting method and provides accurate and precise thickness measurement for plastic films, sheets, paper, foils, silicon wafers and sheetings. Test results will display in real time along with max, min and average value.
Dreaming of Brand Success? Want to see some case studies on great brand practice? Sometimes you learn a lot more from failures than you do successes...so we've brought together some great brand failures that we celebrate as offering us valuable lessons for great brand success. Enjoy!
Creating a great user experience on mobile is both an art and a science. And adding in a beautiful user interface -- that takes real skill. Here are a few tips on designing for mobile from the design pros at HQ. Check us out at http://BuiltbyHQ.com.
VAC-V1 is applicable to the determination of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, sheeting, foils and finished packages, etc.
W3/330 system is based on the electrolytic sensor method to measure water vapor transmission rate of film and package specimens. It has three independent testing cells and can be easily connected with 9 satellite systems.
W3/0120 is based on cup method to measure water vapor transmission rate of plastic films, foils and finished packages. It has 12 independent testing cells and conforms to ASTM, ISO international standards.
TSY-W3 is professionally applicable to determination of water vapor permeability of plastic films, high barrier materials, back-sheets, sheeting, aluminum foils, waterproof materials, and other materials used in sanitary and medical industry.
W3/060 is based on cup method to measure water vapor transmission rate of plastic films, foils and finished packages. It has Six independent testing cells and can be easily connected with 9 satellite systems.
BTY-B2P is based on the differential pressure method, and is professionally applicable to the determination of gas permeability of battery diaphragms, breathable films and other relative polymer products.
G2/130 is based on differential pressure method, and can be used to measure gas transmission rate of flexible containers, including various bottles of carbonated drinks, juice, tea and packages of edible oil, dairy products, washing supplies and metal containers.
ERT-01 Evaporation Residue Constant Weight Tester is professionally designed for the precisely quantitative determination of dissolved substances of table wares, containers, packaging films, cans, tubes and other food-use equipments in different soaking solutions.
BLD-200N Auto Stripping Tester can be used for peeling, stripping and other performance tests of adhesives, adhesive tapes, pressure sensitive tapes, medical adhesive bandage, protective films, release paper, laminated films, leatheroid, woven bags, films and paper.
BMC-B1 is designed for determination of mechanical properties of packaging materials such as plastic films, laminates and paper by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.
CHY-CA is based on mechanical contacting method and applicable to thickness test for plastic films, sheets,paper, foils and other materials within specified range. CHY-CA has auto sampling mechanism.
BLJ-02 is designed for the determination of ink fastness of plastic films and glass paper decorating printed materials that utilize the intaglio printing technique. It also could be used to test adhesion condition of surface layers formed by the technique of vacuum coating, surface coating and lamination.
la toma de decisiones, lo que diferencia unos jugadores de otros. Exposición realizada en la Escuela de Directores Técnicos de Fútbol de la Federación Peruana de Fútbol en enero de 2014. Y durante el I Torneo de la Amistad del Sur, celebrado en Tacna (Perú) en Agosto de 2014. Iván Chaves
CHY-CB is based on contacting method and provides accurate and precise thickness measurement for plastic films, sheets, paper, foils, silicon wafers and sheetings. Test results will display in real time along with max, min and average value.
Dreaming of Brand Success? Want to see some case studies on great brand practice? Sometimes you learn a lot more from failures than you do successes...so we've brought together some great brand failures that we celebrate as offering us valuable lessons for great brand success. Enjoy!
Creating a great user experience on mobile is both an art and a science. And adding in a beautiful user interface -- that takes real skill. Here are a few tips on designing for mobile from the design pros at HQ. Check us out at http://BuiltbyHQ.com.
VAC-VBS is based on the differential pressure method, and can be used for determination of gas transmission rate of films, sheeting, high barrier materials and aluminum foils.
G2/131 is based on differential pressure method and applicable to the determination of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of barrier materials and packages at different temperatures.
G2/131 is based on differential pressure method and applicable to the determination of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient of barrier materials and packages at different temperatures.
G2/132 is based on the differential pressure method and professionally applicable to the determination of gas permeability of film specimens. It is equipped with three diffusion cells.
G2/132 is based on the differential pressure method and professionally applicable to the determination of gas permeability of film specimens. It is equipped with three diffusion cells.
G2/110 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of sole gas or mixed gases in separation membranes.
G2/110 Separation Membrane Permeability Analyzer
G2/110 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of sole gas or mixed gases in separation membranes.
W3/230 is based on the infrared sensor method and designed for the determination of water vapor transmission rate of film and package specimens. It is applicable to various materials with high, medium and low water vapor permeability.
MGT-01 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of various components of mixed gas.
OX2/231 is based on the equal pressure method, and professional applicable to the determination of oxygen transmission rate of plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.
DM2/330 is based on differential and equal pressure method, and applicable to gas permeability test of films and packages. It is designed for the test of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient.
DM2/330 is based on differential and equal pressure method, and applicable to gas permeability test of films and packages. It is designed for the test of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient.
DM2/330 is based on differential and equal pressure method, and applicable to gas permeability test of films and packages. It is designed for the test of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient.
OR2/411 is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of organic gas permeability of various films and sheeting materials.
CHY-C2A is based on contacting method and provides accurate and precise thickness measurement for plastic films, sheets, paper, foils, silicon wafers and sheetings. Test results will display in real time along with max, min and average value.
CHY-C2A Thickness Tester is designed based on mechanical contacting method, which effectively ensures standard and accurate test data and is applicable to thickness test of plastic films, sheets, diaphragms, paper, foils, silicon wafers and other materials within specified range.
CHY-C2A is based on contacting method and provides accurate and precise thickness measurement for plastic films, sheets, paper, foils, silicon wafers and sheetings. Test results will display in real time along with max, min and average value.
G2/130 is based on differential pressure method, and can be used to measure gas transmission rate of flexible containers, including various bottles of carbonated drinks, juice, tea and packages of edible oil, dairy products, washing supplies and metal containers.
G2/130 is based on differential pressure method, and can be used to measure gas transmission rate of flexible containers, including various bottles of carbonated drinks, juice, tea and packages of edible oil, dairy products, washing supplies and metal containers.
This instrument is based on the humidity sensor method, and is professionally applicable to the water vapor transmission rate test of film specimens. It is equipped with three individual test dishes, and the testing process is completely automatic and conforms to international standards.
Core technology of Hyundai Motor Group's EV platform 'E-GMP'Hyundai Motor Group
What’s the force behind Hyundai Motor Group's EV performance and quality?
Maximized driving performance and quick charging time through high-density battery pack and fast charging technology and applicable to various vehicle types!
Discover more about Hyundai Motor Group’s EV platform ‘E-GMP’!
"Trans Failsafe Prog" on your BMW X5 indicates potential transmission issues requiring immediate action. This safety feature activates in response to abnormalities like low fluid levels, leaks, faulty sensors, electrical or mechanical failures, and overheating.
In this presentation, we have discussed a very important feature of BMW X5 cars… the Comfort Access. Things that can significantly limit its functionality. And things that you can try to restore the functionality of such a convenient feature of your vehicle.
What Exactly Is The Common Rail Direct Injection System & How Does It WorkMotor Cars International
Learn about Common Rail Direct Injection (CRDi) - the revolutionary technology that has made diesel engines more efficient. Explore its workings, advantages like enhanced fuel efficiency and increased power output, along with drawbacks such as complexity and higher initial cost. Compare CRDi with traditional diesel engines and discover why it's the preferred choice for modern engines.
Symptoms like intermittent starting and key recognition errors signal potential problems with your Mercedes’ EIS. Use diagnostic steps like error code checks and spare key tests. Professional diagnosis and solutions like EIS replacement ensure safe driving. Consult a qualified technician for accurate diagnosis and repair.
Why Is Your BMW X3 Hood Not Responding To Release CommandsDart Auto
Experiencing difficulty opening your BMW X3's hood? This guide explores potential issues like mechanical obstruction, hood release mechanism failure, electrical problems, and emergency release malfunctions. Troubleshooting tips include basic checks, clearing obstructions, applying pressure, and using the emergency release.
𝘼𝙣𝙩𝙞𝙦𝙪𝙚 𝙋𝙡𝙖𝙨𝙩𝙞𝙘 𝙏𝙧𝙖𝙙𝙚𝙧𝙨 𝙞𝙨 𝙫𝙚𝙧𝙮 𝙛𝙖𝙢𝙤𝙪𝙨 𝙛𝙤𝙧 𝙢𝙖𝙣𝙪𝙛𝙖𝙘𝙩𝙪𝙧𝙞𝙣𝙜 𝙩𝙝𝙚𝙞𝙧 𝙥𝙧𝙤𝙙𝙪𝙘𝙩𝙨. 𝙒𝙚 𝙝𝙖𝙫𝙚 𝙖𝙡𝙡 𝙩𝙝𝙚 𝙥𝙡𝙖𝙨𝙩𝙞𝙘 𝙜𝙧𝙖𝙣𝙪𝙡𝙚𝙨 𝙪𝙨𝙚𝙙 𝙞𝙣 𝙖𝙪𝙩𝙤𝙢𝙤𝙩𝙞𝙫𝙚 𝙖𝙣𝙙 𝙖𝙪𝙩𝙤 𝙥𝙖𝙧𝙩𝙨 𝙖𝙣𝙙 𝙖𝙡𝙡 𝙩𝙝𝙚 𝙛𝙖𝙢𝙤𝙪𝙨 𝙘𝙤𝙢𝙥𝙖𝙣𝙞𝙚𝙨 𝙗𝙪𝙮 𝙩𝙝𝙚 𝙜𝙧𝙖𝙣𝙪𝙡𝙚𝙨 𝙛𝙧𝙤𝙢 𝙪𝙨.
Over the 10 years, we have gained a strong foothold in the market due to our range's high quality, competitive prices, and time-lined delivery schedules.
5 Warning Signs Your BMW's Intelligent Battery Sensor Needs AttentionBertini's German Motors
IBS monitors and manages your BMW’s battery performance. If it malfunctions, you will have to deal with an array of electrical issues in your vehicle. Recognize warning signs like dimming headlights, frequent battery replacements, and electrical malfunctions to address potential IBS issues promptly.
What Does the Active Steering Malfunction Warning Mean for Your BMWTanner Motors
Discover the reasons why your BMW’s Active Steering malfunction warning might come on. From electrical glitches to mechanical failures and software anomalies, addressing these promptly with professional inspection and maintenance ensures continued safety and performance on the road, maintaining the integrity of your driving experience.
What Does the PARKTRONIC Inoperative, See Owner's Manual Message Mean for You...Autohaus Service and Sales
Learn what "PARKTRONIC Inoperative, See Owner's Manual" means for your Mercedes-Benz. This message indicates a malfunction in the parking assistance system, potentially due to sensor issues or electrical faults. Prompt attention is crucial to ensure safety and functionality. Follow steps outlined for diagnosis and repair in the owner's manual.
Comprehensive program for Agricultural Finance, the Automotive Sector, and Empowerment . We will define the full scope and provide a detailed two-week plan for identifying strategic partners in each area within Limpopo, including target areas.:
1. Agricultural : Supporting Primary and Secondary Agriculture
• Scope: Provide support solutions to enhance agricultural productivity and sustainability.
• Target Areas: Polokwane, Tzaneen, Thohoyandou, Makhado, and Giyani.
2. Automotive Sector: Partnerships with Mechanics and Panel Beater Shops
• Scope: Develop collaborations with automotive service providers to improve service quality and business operations.
• Target Areas: Polokwane, Lephalale, Mokopane, Phalaborwa, and Bela-Bela.
3. Empowerment : Focusing on Women Empowerment
• Scope: Provide business support support and training to women-owned businesses, promoting economic inclusion.
• Target Areas: Polokwane, Thohoyandou, Musina, Burgersfort, and Louis Trichardt.
We will also prioritize Industrial Economic Zone areas and their priorities.
Sign up on https://profilesmes.online/welcome/
To be eligible:
1. You must have a registered business and operate in Limpopo
2. Generate revenue
3. Sectors : Agriculture ( primary and secondary) and Automative
Women and Youth are encouraged to apply even if you don't fall in those sectors.
Things to remember while upgrading the brakes of your carjennifermiller8137
Upgrading the brakes of your car? Keep these things in mind before doing so. Additionally, start using an OBD 2 GPS tracker so that you never miss a vehicle maintenance appointment. On top of this, a car GPS tracker will also let you master good driving habits that will let you increase the operational life of your car’s brakes.
Things to remember while upgrading the brakes of your car
BTY B2 P-Gas-Permeability-Tester
1. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140
www.labthinkinter n atio n al.com.cn
BTY-B2P is based on the differential pressure method, and professionally applicable to the determination of gas permeability of battery diaphragms, breathable films and other relative polymer products.
Professional Technology
3 equivalent specimens can be tested simultaneously with the average value as test result
The system supports unit conversion function to meet user’s requirements for special test
The instrument is controlled by computer and test process is finished automatically
Two test modes of proportional and standard modes are available
Customization of test functions is available for special materials
Equipped with RS232 port for convenient data transfer
Supports LystemTM Lab Data Sharing System for uniform and systematic management of test results and reports
Test Principle
Under certain temperature and humidity, a constant gas differential pressure is generated between the two sides of specimen. The gas transmission rate and other parameters can be obtained by analyzing calculating pressure changes in the lower pressure side.
This test instrument conforms to the following standards:
ISO 5636, SJT 1071.9
Applications
This instrument is applicable to the determination of gas permeability of:
Basic Applications
Test the gas permeability of battery diaphragms, breathable films and other relative polymer products.
Technical Specifications
Specifications
Film Test
Test Range
10 ~ 10,000 s/in2·100 mL·1.22KPa
Pressure Range
0~20 KPa (customization is available for others)
Resolution
0.1 Pa
Specimen Size
Φ12 mm
Test Area
0.025 sq.in. (0.16 cm2)
Number of Specimens
3, 2 or 1
Test Gas
O2, N2, CO2 and 99.9% dry gas (outside of supply scope)
BTY-B2P Gas Permeability Tester
PERME®
2. Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140
www.labthinkinter n atio n al.com.cn
Gas Supply Pressure
0.4 MPa
~ 0.6 Port Size
Φ4 mm PU Tubing
Power Supply
AC 220 V 50 HZ
Instrument Dimension
645 mm (L) x 500 mm (W) x 468 mm (H)
Net Weight
60 kg
Configurations
Standard
Configurations
Mainframe, Professional Software, Fast Quantitative Filter Paper, Sampling Plate and Vacuum Grease
Optional Parts
Vacuum Grease
Note
1. The gas supply port of the instrument is Φ4 mm PU tubing;
2. Customers will need to prepare for gas supply.
Please Note: Labthink is always dedicated to the innovation and improvement of product performance function. Therefore, technical specifications are subject to change without further notice. Please visit our website at www.labthinkinternational.com.cn for the latest updates. Labthink reserves rights of final interpretation and revision.