Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
GC-7800 is a classical gas chromatograph instrument which integrates the most advanced chromatography technique and national or international standards with the most extensive applications by the experienced experts of Labthink. It can be widely used to test the relative indexes of various materials, gases, smell, residue, and cigarette packages, because of its powerful functions and high sensitivity. This instrument becomes the best choice for gas chromatographic analysis and control of testing organizations, research institutions, packaging companies as well food and pharmaceutical industries. 
Professional Technology 
 Instrument utilizes patent design of solvent residue test, and is available for the determination purity and water content of hydrophilic solvents. 
 This instrument supports the organic compound determination of packing paper for cigarette boxes and label paper. 
 Controlled by micro-computer with high integrated circuit design and performance. 
 Test specifications are displayed in very clear way by LCD. 
 Full keyboard setting for temperature and detector parameters. 
 Two test modes of constant temperature and program are available with high accuracy less time consuming. 
 Linear temperature program with 5 orders (customization available). 
 Modular designed detector provides more choices for convenient replacement. 
 Practical design of base line auto-zero, power failure protection, and test data storage or inquiry ensures the safe operation condition. 
 Supported by professional chromatography data system with powerful processing functions. 
 The instrument is controlled by micro-computer and integrated circuit, with big display screen. Functions of keyboard inputting parameters, power failure protection and file storage or inquiry provide a comfortable operating environment. 
 Reliable and flexible gas path system is easy to be extended with dual column operation, which is available for different feeding gases or tests and selected in accordance with user analysis requirements. 
 Detectors uses unitized combination design and plug-and-play (PNP) extension control mode. Instrument is equipped with hydrogen flame ionization detector (FID) and thermal conductivity TCD). Four different detectors could be installed simultaneously at most in accordance with user analysis requirements. 
 Constant temperature or program can be achieved in this instrument. And preset of chromatographic column chamber could be reached through automatic open-close of its flexible back door. 
 Sampler system is equipped with packed column, capillary column and other devices to transfer test gases into the system. 
 Instrument is designed with functions of lower pressure for carrier gas 
tube and protection GC-7800 Gas Chromatograph 
PARAM®
Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
transmission interrupt. 
 High temperature protection is applied so that instrument could stop working and alarm when the temperature of any gas tube exceeds the preset (set at 20°C). 
 1500mV wide range of response signal, with good consistency, could meet analysis requirements of high purity samples. 
 Good performance of chromatographic column box makes it possible to achieve the operation at room temperature+3°C, even when the temperatures of detection and vaporizing chambers are as high 200°C. Instrument comes with good repeatability of temperature program to ensure the retention time consistency sample components. 
 Special designed operating software and hardware could automatically monitor the whole process, which creates a safe test environment for users. 
 Instrument could be easily connected with chromatography data converter, system or other graphing devices. 
 Professional chromatographic data system provides powerful and intelligent process function to automatically identify the names and quantities (mg/m2) of residual solvents tested samples in accordance with reference data. Instrument is also available for the detection of solvent purity and water content hydrophilic solvents. 
Test Principle 
A gas chromatograph is a separating or analytical instrument for mixture containing various components. It takes the inert gas as mobile phase, and utilizes chromatographic column separation technology. The mixture injected into the instrument follows the carrier gas into a separation tube known as “column”. Because of different distribution coefficients in the column, distinct components will display different mobile speeds. After certain column, the analyzed components will leave column consecutively into detector where corresponding electrical signals will be generated and taken into chromatography data system. The quantitative analysis of tested mixture is accomplished. 
Applications 
Basic Applications 
Residual Solvent 
For the residual solvent analysis test of plastic films, paper-plastic composite films for food and drugs, cigarette packaging materials 
Purity Analysis 
For the purity analysis test of various solvents used in packaging and printing materials 
Moisture Analysis 
For the moisture content analysis test of various solvents used in packaging and printing materials 
Extended Applications 
(Special Accessories or Customization Required) 
Chlorethylene Analysis 
For the content analysis of Chlorethylene 
Automatic Sampler 
Perform the test automatically to minimize the errors caused by human factors
Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
Technical Specifications 
Temperature of Chromatographic Column Chamber 
Temperature Range Room Temperature +3°C~ 400°C 
Temperature Accuracy Better than ±0.1°C 
Temperature Gradient 
Effective range of column is less than 1% 
Temperature Deviation 
Deviation between preset temperature and display temperature is less than 1°C 
Temperature Deviation 
Deviation between preset temperature and actual temperature is less than 2% 
Orders of Temperature Program 
5 orders (customization available) 
Rate of Temperature 0.1 ~ 30°C/min 
Temperature Range of Linear Temperature Program 
Lower than 150 °C while 30°per minute 
Lower than 300 °C while 15°per minute 
Lower than 350 °C while 10°per minute 
Control Time from Primary to Terminal Temperature 
0 ~ 600 min 
Repeatability of Temperature Program 
Less than 2% 
Temperature Decreasing Speed 
Less than 15min from 300°C 
to 50°(While temperatures of vaporizing and test chambers increase to 300 °C) 
Vaporizing Chamber 
Temperature Accuracy 
±0.1°C(room temperature +15°C~ 200°C) 
±0.2°C while temperature is higher than 200°C 
Test Chamber 
Temperature Accuracy 
±0.1°C(room temperature +15°C~ 200°C) 
±0.2°C while temperature is higher than 200°C 
Flame Ionization Detector (FID) 
Test Limit 
Less than 1×10-11g/s (Benzene) 
Noise 
Less than 0.025 mV 
Drift 
Less than 0.15 mV/h 
Thermal Conductivity Detector (TCD) 
Sensitivity 
More than 3000 mV·mL/mg (Benzene) 
Noise 
Less than 0.035 mV 
Drift 
Less than 0.5 mV/h 
Mainframe 
Power Supply 
AC 220V 50HZ 
Instrument Dimension 
620 mm (L) x 490 mm (W) x 480 mm (H) 
Net Weight 
55 kg 
Configurations 
Standard Configurations 
Gas Chromatograph Mainframe, Hydrogen Flame Ionization Detector, Thermal Conductivity Detector, Water Analytical Column, Capillary Analytical and Chromatography Data System 
Note 
1. Customers will need to prepare for gas supply (high purity nitrogen, hydrogen, dry and oil-free air), analytical reagent (added in the process of printing or composition),
Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 
www.labthinkinter n atio n al.com.cn 
headspace bottle, 1mL glass syringe (with 5# needle), and computer. 
2. Chromatographic analysis laboratory of Labthink will build test methods and provide operation training for free. 
Please Note: Labthink is always dedicated to the innovation and improvement of product performance and function. Therefore, technical specifications are subject to change without further notice. Please visit our website at www.labthinkinternational.com.cn for the latest updates. Labthink reserves rights of final interpretation and revision.

More Related Content

What's hot

W3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-systemW3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-systemEmilywu12
 
QUALIFICATION OF HPLC , HPLC
QUALIFICATION OF HPLC , HPLCQUALIFICATION OF HPLC , HPLC
QUALIFICATION OF HPLC , HPLC
suriyapriya kamaraj
 
Organic Gas Permeability Analyzer
Organic Gas Permeability AnalyzerOrganic Gas Permeability Analyzer
Organic Gas Permeability Analyzer
Labthink Instruments Co., Ltd
 
Mixed Gas Permeability Analyzer
Mixed Gas Permeability AnalyzerMixed Gas Permeability Analyzer
Mixed Gas Permeability Analyzer
Labthink Instruments Co., Ltd
 
Salas 70 pages - master slide show - chris and sabina 21.01.2015
Salas   70 pages - master slide show - chris and sabina 21.01.2015Salas   70 pages - master slide show - chris and sabina 21.01.2015
Salas 70 pages - master slide show - chris and sabina 21.01.2015
Chris Kuntz
 
Qualification of HPLC
Qualification of HPLCQualification of HPLC
Qualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumarQualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumar
himaja donthula
 
W3-031-Water-Vapor-Transmission-rate-Tester
W3-031-Water-Vapor-Transmission-rate-TesterW3-031-Water-Vapor-Transmission-rate-Tester
W3-031-Water-Vapor-Transmission-rate-Tester
Labthink International,Inc.
 
PermMate, Oxygen Permeation Analysis
PermMate, Oxygen Permeation AnalysisPermMate, Oxygen Permeation Analysis
PermMate, Oxygen Permeation Analysis
SystechIllinois
 
Qualification of gc equipment
Qualification of gc equipmentQualification of gc equipment
Qualification of gc equipment
srikrupa institute of pharmaceutical analysis
 

What's hot (10)

W3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-systemW3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-system
 
QUALIFICATION OF HPLC , HPLC
QUALIFICATION OF HPLC , HPLCQUALIFICATION OF HPLC , HPLC
QUALIFICATION OF HPLC , HPLC
 
Organic Gas Permeability Analyzer
Organic Gas Permeability AnalyzerOrganic Gas Permeability Analyzer
Organic Gas Permeability Analyzer
 
Mixed Gas Permeability Analyzer
Mixed Gas Permeability AnalyzerMixed Gas Permeability Analyzer
Mixed Gas Permeability Analyzer
 
Salas 70 pages - master slide show - chris and sabina 21.01.2015
Salas   70 pages - master slide show - chris and sabina 21.01.2015Salas   70 pages - master slide show - chris and sabina 21.01.2015
Salas 70 pages - master slide show - chris and sabina 21.01.2015
 
Qualification of HPLC
Qualification of HPLCQualification of HPLC
Qualification of HPLC
 
Qualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumarQualification of gc equipment by manoj kumar
Qualification of gc equipment by manoj kumar
 
W3-031-Water-Vapor-Transmission-rate-Tester
W3-031-Water-Vapor-Transmission-rate-TesterW3-031-Water-Vapor-Transmission-rate-Tester
W3-031-Water-Vapor-Transmission-rate-Tester
 
PermMate, Oxygen Permeation Analysis
PermMate, Oxygen Permeation AnalysisPermMate, Oxygen Permeation Analysis
PermMate, Oxygen Permeation Analysis
 
Qualification of gc equipment
Qualification of gc equipmentQualification of gc equipment
Qualification of gc equipment
 

Viewers also liked

Nightlife Final
Nightlife FinalNightlife Final
Nightlife Final
Olivia Tucker
 
Cms 498 chapter 9 presentation
Cms 498 chapter 9 presentationCms 498 chapter 9 presentation
Cms 498 chapter 9 presentationChris Bernard
 
FT-F1-Fogging-Tester
FT-F1-Fogging-TesterFT-F1-Fogging-Tester
FT-F1-Fogging-Tester
Emilywu12
 
Cms 498 chapter 9 presentation
Cms 498 chapter 9 presentationCms 498 chapter 9 presentation
Cms 498 chapter 9 presentationChris Bernard
 
Ox2/231 Oxygen Permeability Tester
Ox2/231 Oxygen Permeability TesterOx2/231 Oxygen Permeability Tester
Ox2/231 Oxygen Permeability Tester
Emilywu12
 
G2 131-Gas-permeability-tester
G2 131-Gas-permeability-testerG2 131-Gas-permeability-tester
G2 131-Gas-permeability-tester
Emilywu12
 
Family collage project
Family collage projectFamily collage project
Family collage projectChris Bernard
 
Family collage project
Family collage projectFamily collage project
Family collage projectChris Bernard
 
Community based research project
Community based research projectCommunity based research project
Community based research projectrmhamman
 
Gc 6890-Gas-chromatograph
Gc 6890-Gas-chromatographGc 6890-Gas-chromatograph
Gc 6890-Gas-chromatograph
Emilywu12
 
GC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosamplerGC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosampler
Emilywu12
 
Boniface Doegar Sociology Presentation
Boniface Doegar Sociology Presentation Boniface Doegar Sociology Presentation
Boniface Doegar Sociology Presentation
scsu21
 

Viewers also liked (13)

Nightlife Final
Nightlife FinalNightlife Final
Nightlife Final
 
Cms 498 chapter 9 presentation
Cms 498 chapter 9 presentationCms 498 chapter 9 presentation
Cms 498 chapter 9 presentation
 
FT-F1-Fogging-Tester
FT-F1-Fogging-TesterFT-F1-Fogging-Tester
FT-F1-Fogging-Tester
 
Cms 498 chapter 9 presentation
Cms 498 chapter 9 presentationCms 498 chapter 9 presentation
Cms 498 chapter 9 presentation
 
Ox2/231 Oxygen Permeability Tester
Ox2/231 Oxygen Permeability TesterOx2/231 Oxygen Permeability Tester
Ox2/231 Oxygen Permeability Tester
 
G2 131-Gas-permeability-tester
G2 131-Gas-permeability-testerG2 131-Gas-permeability-tester
G2 131-Gas-permeability-tester
 
Family collage project
Family collage projectFamily collage project
Family collage project
 
Family collage project
Family collage projectFamily collage project
Family collage project
 
Community based research project
Community based research projectCommunity based research project
Community based research project
 
Gc 6890-Gas-chromatograph
Gc 6890-Gas-chromatographGc 6890-Gas-chromatograph
Gc 6890-Gas-chromatograph
 
маркетинг проекта Poworot
маркетинг проекта Poworotмаркетинг проекта Poworot
маркетинг проекта Poworot
 
GC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosamplerGC-7800-Gas-chromatograph-with-autosampler
GC-7800-Gas-chromatograph-with-autosampler
 
Boniface Doegar Sociology Presentation
Boniface Doegar Sociology Presentation Boniface Doegar Sociology Presentation
Boniface Doegar Sociology Presentation
 

Similar to Gc 7800-gas-chromatograph

GC-6890-Gas Chromatograph for Cigarette Packaging Materials
GC-6890-Gas Chromatograph for Cigarette Packaging MaterialsGC-6890-Gas Chromatograph for Cigarette Packaging Materials
GC-6890-Gas Chromatograph for Cigarette Packaging Materials
Labthink International,Inc.
 
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-LabthinkG2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
Labthink International,Inc.
 
G2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzerG2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzer
Emilywu12
 
MGT-01-Mixed-Gas-Permeability-Analyzer
MGT-01-Mixed-Gas-Permeability-AnalyzerMGT-01-Mixed-Gas-Permeability-Analyzer
MGT-01-Mixed-Gas-Permeability-Analyzer
Labthink International,Inc.
 
W3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-systemW3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-system
Labthink International,Inc.
 
G2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and SheetingG2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and Sheeting
Labthink International,Inc.
 
G2 130-Container-gas-permeability-tester
G2 130-Container-gas-permeability-testerG2 130-Container-gas-permeability-tester
G2 130-Container-gas-permeability-tester
Emilywu12
 
G2-130 Container Gas Permeability Tester for Dairy Product Packages
G2-130 Container Gas Permeability Tester for Dairy Product Packages G2-130 Container Gas Permeability Tester for Dairy Product Packages
G2-130 Container Gas Permeability Tester for Dairy Product Packages
Labthink International,Inc.
 
G2 130-Container-Gas-Permeability-Tester
G2 130-Container-Gas-Permeability-TesterG2 130-Container-Gas-Permeability-Tester
G2 130-Container-Gas-Permeability-Tester
Labthink International,Inc.
 
OR2-411-Organic-Gas-Permeability-Analyzer
OR2-411-Organic-Gas-Permeability-AnalyzerOR2-411-Organic-Gas-Permeability-Analyzer
OR2-411-Organic-Gas-Permeability-Analyzer
Labthink International,Inc.
 
G2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-FilmsG2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-Films
Labthink International,Inc.
 
G2 132-Gas-permeability-tester
G2 132-Gas-permeability-testerG2 132-Gas-permeability-tester
G2 132-Gas-permeability-tester
Emilywu12
 
Oxygen transmittance tester
Oxygen transmittance testerOxygen transmittance tester
Oxygen transmittance tester
labmen1998
 
HGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-AnalyzerHGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-Analyzer
Labthink International,Inc.
 
W3-060-Water-Vapor-transmission-rate-test-system
W3-060-Water-Vapor-transmission-rate-test-systemW3-060-Water-Vapor-transmission-rate-test-system
W3-060-Water-Vapor-transmission-rate-test-system
Labthink International,Inc.
 
Gas-Chromatography.pdf
Gas-Chromatography.pdfGas-Chromatography.pdf
Gas-Chromatography.pdf
labotronicsmary
 
BTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragmsBTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragms
Labthink International,Inc.
 
BTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-TesterBTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-Tester
Labthink International,Inc.
 
BTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-TesterBTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-Tester
Emilywu12
 

Similar to Gc 7800-gas-chromatograph (20)

GC-6890-Gas Chromatograph for Cigarette Packaging Materials
GC-6890-Gas Chromatograph for Cigarette Packaging MaterialsGC-6890-Gas Chromatograph for Cigarette Packaging Materials
GC-6890-Gas Chromatograph for Cigarette Packaging Materials
 
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-LabthinkG2-110-Separation-Membrane-Permeability-Analyzer-Labthink
G2-110-Separation-Membrane-Permeability-Analyzer-Labthink
 
G2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzerG2 110-Separation-membrane-permeability-analyzer
G2 110-Separation-membrane-permeability-analyzer
 
MGT-01-Mixed-Gas-Permeability-Analyzer
MGT-01-Mixed-Gas-Permeability-AnalyzerMGT-01-Mixed-Gas-Permeability-Analyzer
MGT-01-Mixed-Gas-Permeability-Analyzer
 
W3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-systemW3 230-water-vapor-transmission-rate-test-system
W3 230-water-vapor-transmission-rate-test-system
 
G2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and SheetingG2-131-Gas Permeability Tester for Films and Sheeting
G2-131-Gas Permeability Tester for Films and Sheeting
 
G2 130-Container-gas-permeability-tester
G2 130-Container-gas-permeability-testerG2 130-Container-gas-permeability-tester
G2 130-Container-gas-permeability-tester
 
G2-130 Container Gas Permeability Tester for Dairy Product Packages
G2-130 Container Gas Permeability Tester for Dairy Product Packages G2-130 Container Gas Permeability Tester for Dairy Product Packages
G2-130 Container Gas Permeability Tester for Dairy Product Packages
 
G2 130-Container-Gas-Permeability-Tester
G2 130-Container-Gas-Permeability-TesterG2 130-Container-Gas-Permeability-Tester
G2 130-Container-Gas-Permeability-Tester
 
OR2-411-Organic-Gas-Permeability-Analyzer
OR2-411-Organic-Gas-Permeability-AnalyzerOR2-411-Organic-Gas-Permeability-Analyzer
OR2-411-Organic-Gas-Permeability-Analyzer
 
HGA 03-Headspace-Gas-Analyzer
HGA 03-Headspace-Gas-AnalyzerHGA 03-Headspace-Gas-Analyzer
HGA 03-Headspace-Gas-Analyzer
 
G2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-FilmsG2 132-Gas-Permeability-Tester-for-Paint-Films
G2 132-Gas-Permeability-Tester-for-Paint-Films
 
G2 132-Gas-permeability-tester
G2 132-Gas-permeability-testerG2 132-Gas-permeability-tester
G2 132-Gas-permeability-tester
 
Oxygen transmittance tester
Oxygen transmittance testerOxygen transmittance tester
Oxygen transmittance tester
 
HGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-AnalyzerHGA 02-Headspace-Gas-Analyzer
HGA 02-Headspace-Gas-Analyzer
 
W3-060-Water-Vapor-transmission-rate-test-system
W3-060-Water-Vapor-transmission-rate-test-systemW3-060-Water-Vapor-transmission-rate-test-system
W3-060-Water-Vapor-transmission-rate-test-system
 
Gas-Chromatography.pdf
Gas-Chromatography.pdfGas-Chromatography.pdf
Gas-Chromatography.pdf
 
BTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragmsBTY-B2P-Gas Permeability Tester for battery diaphragms
BTY-B2P-Gas Permeability Tester for battery diaphragms
 
BTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-TesterBTY B2 P-Gas-Permeability-Tester
BTY B2 P-Gas-Permeability-Tester
 
BTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-TesterBTY-B2P-Gas-Permeability-Tester
BTY-B2P-Gas-Permeability-Tester
 

Recently uploaded

web-tech-lab-manual-final-abhas.pdf. Jer
web-tech-lab-manual-final-abhas.pdf. Jerweb-tech-lab-manual-final-abhas.pdf. Jer
web-tech-lab-manual-final-abhas.pdf. Jer
freshgammer09
 
Drugs used in parkinsonism and other movement disorders.pptx
Drugs used in parkinsonism and other movement disorders.pptxDrugs used in parkinsonism and other movement disorders.pptx
Drugs used in parkinsonism and other movement disorders.pptx
ThalapathyVijay15
 
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
PinkySharma900491
 
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
Amil baba
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
eemet
 
Cyber Sequrity.pptx is life of cyber security
Cyber Sequrity.pptx is life of cyber securityCyber Sequrity.pptx is life of cyber security
Cyber Sequrity.pptx is life of cyber security
perweeng31
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
kywwoyk
 
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
kywwoyk
 
F5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptxF5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptx
ArjunJain44
 

Recently uploaded (9)

web-tech-lab-manual-final-abhas.pdf. Jer
web-tech-lab-manual-final-abhas.pdf. Jerweb-tech-lab-manual-final-abhas.pdf. Jer
web-tech-lab-manual-final-abhas.pdf. Jer
 
Drugs used in parkinsonism and other movement disorders.pptx
Drugs used in parkinsonism and other movement disorders.pptxDrugs used in parkinsonism and other movement disorders.pptx
Drugs used in parkinsonism and other movement disorders.pptx
 
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...
 
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
 
Cyber Sequrity.pptx is life of cyber security
Cyber Sequrity.pptx is life of cyber securityCyber Sequrity.pptx is life of cyber security
Cyber Sequrity.pptx is life of cyber security
 
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
一比一原版SDSU毕业证圣地亚哥州立大学毕业证成绩单如何办理
 
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
一比一原版UVM毕业证佛蒙特大学毕业证成绩单如何办理
 
F5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptxF5 LTM TROUBLESHOOTING Guide latest.pptx
F5 LTM TROUBLESHOOTING Guide latest.pptx
 

Gc 7800-gas-chromatograph

  • 1. Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn GC-7800 is a classical gas chromatograph instrument which integrates the most advanced chromatography technique and national or international standards with the most extensive applications by the experienced experts of Labthink. It can be widely used to test the relative indexes of various materials, gases, smell, residue, and cigarette packages, because of its powerful functions and high sensitivity. This instrument becomes the best choice for gas chromatographic analysis and control of testing organizations, research institutions, packaging companies as well food and pharmaceutical industries. Professional Technology  Instrument utilizes patent design of solvent residue test, and is available for the determination purity and water content of hydrophilic solvents.  This instrument supports the organic compound determination of packing paper for cigarette boxes and label paper.  Controlled by micro-computer with high integrated circuit design and performance.  Test specifications are displayed in very clear way by LCD.  Full keyboard setting for temperature and detector parameters.  Two test modes of constant temperature and program are available with high accuracy less time consuming.  Linear temperature program with 5 orders (customization available).  Modular designed detector provides more choices for convenient replacement.  Practical design of base line auto-zero, power failure protection, and test data storage or inquiry ensures the safe operation condition.  Supported by professional chromatography data system with powerful processing functions.  The instrument is controlled by micro-computer and integrated circuit, with big display screen. Functions of keyboard inputting parameters, power failure protection and file storage or inquiry provide a comfortable operating environment.  Reliable and flexible gas path system is easy to be extended with dual column operation, which is available for different feeding gases or tests and selected in accordance with user analysis requirements.  Detectors uses unitized combination design and plug-and-play (PNP) extension control mode. Instrument is equipped with hydrogen flame ionization detector (FID) and thermal conductivity TCD). Four different detectors could be installed simultaneously at most in accordance with user analysis requirements.  Constant temperature or program can be achieved in this instrument. And preset of chromatographic column chamber could be reached through automatic open-close of its flexible back door.  Sampler system is equipped with packed column, capillary column and other devices to transfer test gases into the system.  Instrument is designed with functions of lower pressure for carrier gas tube and protection GC-7800 Gas Chromatograph PARAM®
  • 2. Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn transmission interrupt.  High temperature protection is applied so that instrument could stop working and alarm when the temperature of any gas tube exceeds the preset (set at 20°C).  1500mV wide range of response signal, with good consistency, could meet analysis requirements of high purity samples.  Good performance of chromatographic column box makes it possible to achieve the operation at room temperature+3°C, even when the temperatures of detection and vaporizing chambers are as high 200°C. Instrument comes with good repeatability of temperature program to ensure the retention time consistency sample components.  Special designed operating software and hardware could automatically monitor the whole process, which creates a safe test environment for users.  Instrument could be easily connected with chromatography data converter, system or other graphing devices.  Professional chromatographic data system provides powerful and intelligent process function to automatically identify the names and quantities (mg/m2) of residual solvents tested samples in accordance with reference data. Instrument is also available for the detection of solvent purity and water content hydrophilic solvents. Test Principle A gas chromatograph is a separating or analytical instrument for mixture containing various components. It takes the inert gas as mobile phase, and utilizes chromatographic column separation technology. The mixture injected into the instrument follows the carrier gas into a separation tube known as “column”. Because of different distribution coefficients in the column, distinct components will display different mobile speeds. After certain column, the analyzed components will leave column consecutively into detector where corresponding electrical signals will be generated and taken into chromatography data system. The quantitative analysis of tested mixture is accomplished. Applications Basic Applications Residual Solvent For the residual solvent analysis test of plastic films, paper-plastic composite films for food and drugs, cigarette packaging materials Purity Analysis For the purity analysis test of various solvents used in packaging and printing materials Moisture Analysis For the moisture content analysis test of various solvents used in packaging and printing materials Extended Applications (Special Accessories or Customization Required) Chlorethylene Analysis For the content analysis of Chlorethylene Automatic Sampler Perform the test automatically to minimize the errors caused by human factors
  • 3. Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn Technical Specifications Temperature of Chromatographic Column Chamber Temperature Range Room Temperature +3°C~ 400°C Temperature Accuracy Better than ±0.1°C Temperature Gradient Effective range of column is less than 1% Temperature Deviation Deviation between preset temperature and display temperature is less than 1°C Temperature Deviation Deviation between preset temperature and actual temperature is less than 2% Orders of Temperature Program 5 orders (customization available) Rate of Temperature 0.1 ~ 30°C/min Temperature Range of Linear Temperature Program Lower than 150 °C while 30°per minute Lower than 300 °C while 15°per minute Lower than 350 °C while 10°per minute Control Time from Primary to Terminal Temperature 0 ~ 600 min Repeatability of Temperature Program Less than 2% Temperature Decreasing Speed Less than 15min from 300°C to 50°(While temperatures of vaporizing and test chambers increase to 300 °C) Vaporizing Chamber Temperature Accuracy ±0.1°C(room temperature +15°C~ 200°C) ±0.2°C while temperature is higher than 200°C Test Chamber Temperature Accuracy ±0.1°C(room temperature +15°C~ 200°C) ±0.2°C while temperature is higher than 200°C Flame Ionization Detector (FID) Test Limit Less than 1×10-11g/s (Benzene) Noise Less than 0.025 mV Drift Less than 0.15 mV/h Thermal Conductivity Detector (TCD) Sensitivity More than 3000 mV·mL/mg (Benzene) Noise Less than 0.035 mV Drift Less than 0.5 mV/h Mainframe Power Supply AC 220V 50HZ Instrument Dimension 620 mm (L) x 490 mm (W) x 480 mm (H) Net Weight 55 kg Configurations Standard Configurations Gas Chromatograph Mainframe, Hydrogen Flame Ionization Detector, Thermal Conductivity Detector, Water Analytical Column, Capillary Analytical and Chromatography Data System Note 1. Customers will need to prepare for gas supply (high purity nitrogen, hydrogen, dry and oil-free air), analytical reagent (added in the process of printing or composition),
  • 4. Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85812140 www.labthinkinter n atio n al.com.cn headspace bottle, 1mL glass syringe (with 5# needle), and computer. 2. Chromatographic analysis laboratory of Labthink will build test methods and provide operation training for free. Please Note: Labthink is always dedicated to the innovation and improvement of product performance and function. Therefore, technical specifications are subject to change without further notice. Please visit our website at www.labthinkinternational.com.cn for the latest updates. Labthink reserves rights of final interpretation and revision.