1. ED34-862 Specifications
2. Specifications
Ceiling Suspended Cassette Type
Indoor Unit FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1
Model
Connection Unit BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE
kcal/h 7,100 10,000 12,500
★1 Cooling Capacity (19.5°CWB) Btu/h 28,300 39,600 49,500
kW 8.3 11.6 14.5
★2 Cooling Capacity (19.0°CWB) kW 8.0 11.2 14.0
Casing Color White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)
Dimensions: (H×W×D) mm 165×895×895 230×895×895 230×895×895
Coil (Cross Rows×Stages×Fin Pitch mm 3×6×1.5 3×8×1.5 3×8×1.5
Fin Coil) Face Area m² 0.265 0.353 0.353
Model QTS48A10M QTS50B15M QTS50B15M
Type Turbo Fan Turbo Fan Turbo Fan
Motor Output × Number W 45×1 90×1 90×1
Fan of Units
m³/min 19/14 29/21 32/23
Air Flow Rate (H/L)
cfm 671/494 1,024/741 1,130/812
Drive Direct Drive Direct Drive Direct Drive
Temperature Control Microprocessor Thermostat for Microprocessor Thermostat for Microprocessor Thermostat for
Cooling and Heating Cooling and Heating Cooling and Heating
Sound Absorbing Thermal Insulation Material Heat Resistant Foamed Polyethylene, Heat Resistant Foamed Polyethylene, Heat Resistant Foamed Polyethylene,
Regular Foamed Polyethylene Regular Foamed Polyethylene Regular Foamed Polyethylene
Liquid Pipes mm φ9.5 (Flare Connection) φ9.5 (Flare Connection) φ9.5 (Flare Connection)
Piping Gas Pipes mm φ15.9 (Flare Connection) φ15.9 (Flare Connection) φ15.9 (Flare Connection)
Connections
Drain Pipe mm VP20 VP20 VP20
(External Dia. 26 Internal Dia. 20) (External Dia. 26 Internal Dia. 20) (External Dia. 26 Internal Dia. 20)
Machine Weight kg 25 31 31
★4 Sound Level (H/L) (230V) dBA 40/35 43/38 44/39
Safety Devices Thermal Protector for Fan Motor Thermal Protector for Fan Motor Thermal Protector for Fan Motor
Operation Manual, Installation Operation Manual, Installation Operation Manual, Installation
Manual, Drain Hose, Clamp Metal, Manual, Drain Hose, Clamp Metal, Manual, Drain Hose, Clamp Metal,
Standard Accessories Insulation for Fitting, Sealing Pads, Insulation for Fitting, Sealing Pads, Insulation for Fitting, Sealing Pads,
Clamps, Screws, Washers, Holding Clamps, Screws, Washers, Holding Clamps, Screws, Washers, Holding
Plate. Plate. Plate.
Drawing No. C : 4D045395A
Notes:
★1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level difference: 0m. Conversion Formulae 12
★2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level difference: 0m.
kcal/h=kW×860
3 Capacities are net, including a deduction for cooling (an additional for heating) for indoor fan motor heat. Btu/h=kW×3412
★4 Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center. These values are normally somewhat higher cfm=m³/min×35.3
during actual operation as a result of ambient conditions.
5 Refer to page 391 for Fan Motor Input.
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.
FXUQ-MA 383
2. Specifications ED34-862
BEV Units
Model BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE
Power Supply 1 Phase 50Hz 220~240V 1 Phase 50Hz 220~240V 1 Phase 50Hz 220~240V
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Dimensions: (H×W×D) mm 100×350×225 100×350×225 100×350×225
Sound Absorbing Thermal Insulation Flame and Heat Resistant Foamed Flame and Heat Resistant Foamed Flame and Heat Resistant Foamed
Material Polyethylene Polyethylene Polyethylene
Indoor Liquid Pipes 9.5mm (Flare Connection) 9.5mm (Flare Connection) 9.5mm (Flare Connection)
Unit Gas Pipes 15.9mm (Flare Connection) 15.9mm (Flare Connection) 15.9mm (Flare Connection)
Piping
Connection 9.5mm (Flare Connection) 9.5mm (Flare Connection) 9.5mm (Flare Connection)
Outdoor Liquid Pipes
Unit Suction Gas Pipes 15.9mm (Flare Connection) 15.9mm (Flare Connection) 15.9mm (Flare Connection)
Machine Weight (Mass) kg 3.0 3.0 3.5
Installation manual, Gas piping Installation manual, Gas piping Installation manual, Gas piping
Standard Accessories connections, Insulation for fitting, connections, Insulation for fitting, connections, Insulation for fitting,
Sealing material, Clamps Sealing material, Clamps Sealing material, Clamps
Drawing No. 4D045387A 4D045387A 4D045388A
Connection Example
Transmission 1. Wiring Work
line •The connecting line between SkyAir Indoor Unit
Power
supply – BEV Unit : 3 cores…like a Transmission Line
Control line
Wiring
•BEV Unit’s power supply line;
Single phase 2 line…like a VRV Indoor unit
•BEV Unit – other VRV indoor unit or outdoor unit –
: 2 cores…DIII network wiring (super wiring)
BRC1C62 2. Piping work
SkyAir side,Outdoor Unit Side,They are both flare
connection.
Consideration matter
- When connecting centralized-control device, it is necessary to install an interface
adaptor for SkyAir series in an indoor unit.
- Distance between indoor unit and –BEV unit must be within 5m.
Outline figure
Terminal block Gas pipe (With Thermistor,
Insulation pipe cover)
Piping part cover
PC board
SW.BOX cover
Hanger
(Wall surface attachment is also possible)
Liquid pipe
Electric valve drive part
Installation pattern / maintenance
1. Level installation (It hangs by two hangers) 2. Vertical Installation
Hanger bolt Liquid pipe (Wall Surface Mounted)
Service
space*2 Gas pipe
100 or more
Installation Service space*1
Screw fixed
space (x2 Screws x2 place)
150 or more
Service access panel (450 x 450 )
*1; Service space for switch box.
(Service access panel is required for the bottom side. When there is nothing, 350 or more spaces are required. )
*2; For electric valve drive part’s maintenance. (a control box is removed)