Learn about LED based products for analytical spectroscopy applications, advantages over conventional light sources and the easy integration into mobile equipment.
Learning Objectives Include:
- Innovative technical solution - performance of the first broadband UV LED light source FiberLight® L3
- Enabling mobile spectroscopy - advantages of broadband UV LED FiberLight® L3 over conventional light sources, overcoming the limitations of current solutions
Enabling Mobile Spectroscopy: New Light Source Technologies for Analytical Instruments
1. Enabling Mobile Spectroscopy:
New Light Source Technologies
for Analytical Instruments
Tanja Reinert
Product Manager
Heraeus Noblelight
2. AGENDA
Introduction to Heraeus
Requirements for in-field / on-site analysis
Comparison of existing UV light source technologies
New technology to generate a broadband UV spectrum with an LED
FiberLight® L3 in applications
3. HERAEUS – A GLOBALLY SUCCESSFUL PORTFOLIO COMPANY
3
TOTAL REVENUE
in 2019
22.4 bn €
GLOBAL BUSINESS UNITS
market-oriented
11
R&D EXPENDITURES
7%
FAMILY-OWNED COMPANIES in Germany
TOP 10
More than 100 SITES
in 40 COUNTRIES
APPROX.
14,900
Germany 37%
Rest of Europe 15%
Asia 29%
America 18%
Africa/Australia 1%
EMPLOYEES
WORLDWIDE
America
25%
Asia
42%
Germany
11%
Africa/
Australia
2%
Rest of
Europe
20%
including staff leasing
Based on revenues excl. Precious Metals
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
4. AGENDA
Introduction to Heraeus
Requirements for in-field / on-site analysis
Comparison of existing UV light source technologies
New technology to generate a broadband UV spectrum with an LED
FiberLight® L3 in applications
5. Solution: Take your lab to the sample
THE ADVANTAGES OF IN-FIELD / ON-SITE ANALYTICAL MEASUREMENT
5
Solution: Take your
lab to the sample
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
6. Current systems have the big size of an Audio system and are difficult to handle…
THE CHALLENGES OF ANALYTICAL EQUIPMENT
6
…whereas future systems
can have the compact size of a
wireless speaker!
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
7. APPLICATION FIELDS
Water Quality Monitoring Field Monitoring
Environmental Monitoring
› In-field / on site HPLC
Lab Analysis
7 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
8. POINT OF USE ANALYSIS - PARAMETERS FOR INSTRUMENTATION
8
PERIOD OF USE POWER CONSUMPTION
ACCURACY STABILITY
MAINTENANCE CYCLE LIFETIME
SAMPLE VARIETY VERSATILITY
INTERMITTENT USE WARM-UP TIME
TRANSPORTABILITY SIZE AND WEIGHT
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
9. Critical properties for versatile mobile measurement:
›Broadband spectrum
›Small size
›Lightweight
›Low power consumption
POINT OF USE ANALYSIS - NEEDS FOR INSTRUMENTATION
9
Solution: Take your lab to the sample
Solution: Take your lab to the sample
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
10. AGENDA
Introduction to Heraeus
Requirements for in-field / on-site analysis
Comparison of existing UV light source technologies
New technology to generate a broadband UV spectrum with an LED
FiberLight® L3 in applications
11. UVC LED
Single wavelength
Deuterium Lamp
Compact size
Deuterium lamp
Compact size
Xe-flash lamp
Technology LED Gas discharge Gas discharge Gas discharge
Operation Pulsed/continuous Continuous Cyclic/continuous Pulsed
Spectrum Single wavelength only 185 – 400 nm 185 – 1100 nm 185 – 2,000 nm
Power consumption ≤ 2 W 30 W 6 W 7 W
Lifetime (L50) 9,000 h 2,000 h 1,000 h 109 flashes
Stability High High Medium Low
SMA coupling Yes No Yes Yes
COMPARISON OF EXISTING UV LIGHT SOURCE TECHNOLOGIES
11
Solid-State Light Source Gasdischarge Lamp
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
12. Limitations for application in analytical instruments
› Dynamic variations between the LEDs
› High cost for UVC/UVB chips
› Different aging characteristics
› Lifetime is defined by LED with the shortest lifetime
› Failure of a single LED causes failure of the entire device
› Difficulties in optical setup for analytical instruments
› A Point source is required for optical imaging
› The Image will show patterns of different wavelengths
CONTINUUM GENERATION BY MULTI-LED CHIP APPROACH
12
Optical imageLensLED array
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
13. Broadband spectrum
with a single LED!
HERAEUS´ SOLUTION:
[Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments13
14. AGENDA
Introduction to Heraeus
Requirements for in-field / on-site analysis
Comparison of existing UV light source technologies
New technology to generate a broadband UV spectrum with an LED
FiberLight® L3 in applications
15. Spectrum of a single LED…
…broadened by adding multiple phosphors.
BROADBAND UV LED GENERATED BY A SINGLE LED + PHOSPHOR
0
0.2
0.4
0.6
0.8
1
1.2
200 250 300 350 400 450 500 550
LED Phosphor 1 Phosphor 2
0
0.2
0.4
0.6
0.8
1
1.2
200 250 300 350 400 450 500 550
15 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
16. FiberLight® L3 – BROADBAND MEETS UV-LED
16 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
17. UV Broadband spectrum
→ Flexibility in use
→ Easy optical imaging/coupling
Long Lifetime
→ Less maintenance work
→ Less maintenance cost
FiberLight® L3 – UNIQUE AND INNOVATIVE
Low Power Consumption
→ Ideal for portable devices
→ Longer field use possible
Small Size
→ No size restriction
→ Suitable for handheld devices
< 1.5 Watt
> 5,000 h 60 × 63 × 48 mm3
250 – 490 nm
17 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
18. FiberLight® L3 – BROADBAND MEETS UV-LED
Spectral range 250 – 490 nm
Lifetime > 5,000 h
Power consumption < 1,5 W
Optical stability < 0.03% p-p
Size 60 × 63 × 48 mm3
Power supply voltage 3 – 24 V
Operation Pulsed or continuous
Maximum pulse frequency 1 kHz
Weight 0.11 kg
Optical connection SMA905 Fiber coupling
18 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
19. FiberLight® L3
UVC – LED
Single wavelength
FiberLight D2 FiberLight Xe
Technology LED LED Gas discharge Gas discharge
Operation Pulsed / continuous Pulsed / continuous Cyclic/continuous Pulsed
Spectrum 250 – 490 nm Single wavelength 185 – 1100 nm 185 – 2,000 nm
Power
consumption
< 1.5 W ≤ 2 W 6 W 7 W
Lifetime (L50) > 5,000 h 9,000 h 1,000 h 109 flashes
Stability High High Medium Low
SMA coupling Yes Yes Yes Yes
COMPARISON OF SELECTED ANALYTICAL UV LIGHT SOURCES
19 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
20. AGENDA
Introduction to Heraeus
Requirements for in-field / on-site analysis
Comparison of existing UV light source technologies
New technology to generate a broadband UV spectrum with an LED
FiberLight® L3 in applications
21. Absorbance of L-Tryptophan dissolved in water
at different concentrations
› Light guided from source to cuvette using
an optical fiber with 600 µm core diameter
› Cuvette path length: 1 mm
› Light detection with UV/Vis spectrometer
APPLICATION TEST MEASUREMENTS – L-TRYPTOPHAN
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
0.000% 0.005% 0.010% 0.015% 0.020% 0.025%
Absorbanceat274nm
Concentration of L-Tryptophan in water
0.0
0.2
0.4
0.6
0.8
1.0
250 300 350 400 450 500
Transmission
Wavelength [nm]
0,024% 0,012% 0,006% 0,003%
Absorbance Transmission spectra for different concentrations
21 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
22. Transmission spectrum of Ozone
Detection of ozone
› Light guided from source to measurement cell using an optical fiber with 600 µm core diameter
› Detection path length: 3 cm
› Measurement after 2 min of lamp operation
› Light detection with UV/Vis spectrometer
APPLICATION TEST MEASUREMENTS – OZONE DETECTION
0.0
0.2
0.4
0.6
0.8
1.0
250 300 350 400 450 500
Transmission
Wavelength [nm]
22 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
23. › Wider range of applications, because of a true continuous
broadband source
› True point-of-use analysis and faster results because of
measurement at point of sampling
› Potential for more users to detect problems quicker in the
environment
› Enables faster control for a cleaner environment
FiberLight® L3 will bring the opportunities for portable
analytical measurement to the next level!
NEW BROADBAND UV-LIGHT SOURCE TECHNOLOGY ENABLES FIELD BASED
ANALYSIS LIKE NEVER BEFORE
23 [Webinar] Enabling Mobile Spectroscopy – New Light Source Technologies for Analytical Instruments
24. To learn more about Mobile Spectroscopy
from Heraeus Noblelight, please visit:
www.heraeus-noblelight.com/fll3
Thank you for