PRESENTATION
ON
INDUSTRIAL VISIT
TO
OIL INDIA LIMITED CGGS AND OFF-TAKE POINT
MADHUBAN
DEPARTMENT OF PETROLUEM TECHNOLOGY
DIBRUGARH UNIVERSITY
Presented To:
Department Of Petroleum Technology
Presented By:
Students of 1st
Semester
Oil Well Drilling Technology
Batch (2024-2025)
ACKNOWLEDGEMENT:
We Extend Our Heartfelt Gratitude To Dr. Pradip Borgohain, Professor And Head Of The Department Of Petroleum Technology; Dr.
(Mrs.) Subrata Borgohain Gogoi, Professor And Dean Of The Faculty Of Earth, Sciences, And Energy; Dr. Ranjan Phukan, Assistant
Professor; Dr. Dhrubajyoti Neog, Assistant Professor; Dr. Borkha Mech, Assistant Professor; And Dr. Himanta Borgohain, Assistant
Professor, All From The Department Of Petroleum Technology, Dibrugarh University, For Organizing A One-day Industrial Visit To The
CGGS Facility Of Oil India Limited, Duliajan.
As Part Of Our Course Curriculum. We Also Wish To Express Our Sincere Appreciation To Mr. Pankaj Kumar Das, Installation Manager;
Mr. ------------, ---; And The Entire Team Of CGGS At Oil India Limited For Their Guidance And For Providing An Insightful Demonstration
Of The Various Technical Aspects And Equipment At The Well Site. Their Dedication And Hospitality Played A Pivotal Role In Making
This Industrial Visit A Remarkable Success. The Opportunity To Gain Hands-on Exposure To The Operations At CGGS Was An Invaluable
And Enlightening Experience For All Of Us.
Regards:
Batch (2024-2025), 1st
Semester
Oil Well Drilling Technology
CONTENT:
 INTRODUCTION
 OVERALL LAYOUT DIAGRAM OF CGGS
 GAS FLOW DIAGRAM
 GAS MEASUREMENTS SYSTEM
 SAFETY MEASURES
 CONCLUSION
INTRODUCTION:
 CGGS Is Constructed In Madhuban Near Well NHK#50, At A Distance Of
6km From Duliajan, Dibrugarh District.
 Constructed To Supply 6mmscmd Of Natural Gas Containing Atleast 7% C2
+ Components To BCPL From A Single Point.
 There Are 9 Incoming Lines From Different Fields.
 Gas Handling Capacity 12.50 MMSCMD.
 Natural Gas Liquid Handling Capacity 1250 KLPD.
OVERALL LAYOUT DIAGRAM OF CGGS:
GAS CYCLE
LP Indirect Bath Heater
• Used for variety of purpose
• Usually for heating Natural Gas
• Works as a dual fuel burner for Natural Gas and LPG
• Enter in a heated bath before entering LP Seperator
Heater Treater
• It is 3 phase separator vessel
• Helps to utilise heat and mechanical separation
• Facilates the separation of oil water emulsion
before transporting the dry oil thorugh pipeline
• Heater Treater consists of 3 Section
 Degasing
 Heating
 Differential Oil Control
GAS FLOW DIAGRAM:
A Finger-type Slug Catchers is specialized slug catching system that uses a series of long, horizontal pipes
(referred to as “fingers”) to handle and separate slugs in a pipeline.
Enclosed Ground Flare System
GAS MEASUREMENTS SYSTEM:
Gas Measurement System Ultrasonic Flowmeters And Gas Chromatographs Are Essential Tools In Gas
Measurement Systems
 An Ultrasonic Flowmeter Is Increasingly Used In Custody Transfer Applications.
 Gas Chromatograph Is Used For Flow & Energy Measurement And Quality Monitoring Of Gas
SAFETY MEASURES:
1. Firewater System in the Oil and Gas Industry:
 Firewater Pumps
 Jockey Pump
 Firewater Network
 Hydrants and Monitors
 Sprinklers
2. Fire Detection and Suppression System:
 Smoke Detectors
 Heat Detectors
 Gas Detectors
 Gas Based System
 Foam Based System
 Powder Based System
3. The AFFF (Aqueous Film Foaming Foam):
 Foam Concentrate
 Foam Proportioner
 Foam Pourers
 Foam Generator
 Storage Tank
 Water Supply System
 Control Panel
 Detection And Activation
4. Emergency Shutdown (ESD) System:
 Process Isolation
 Equipment Shutdown
 Emergency Venting
 Fire And Gas Detection Integration
COMMON SAFETY POINTS:
CONCLUSION:
 CGGS Was Initially Envisioned To Supply 6 MMSCFD Of Rich Gas To BCPL .
 BCPL Consumes 1.35 MMSCFD And Returns 4.65 Mmscfd .
 Oil Also Supplies Gas To Bvfcl , Neepco , Apgcl , Nrl , Apl , Ioc-aod , Tea Grids , Small Industries And Png .
 The Facility Features Slug Catchers , Kod , Filter Seperator, Headers , Oil Water Separator , Effluent Treatment
Plant , Condensate Tank , Flare System , Ultrasonic Flowmeters And Gas Chromatographs .
 Safety Is The Topmost Priority In Any Industrial Plant . Safety Features Like Smoke Detectors, Esd, Fire Water
Pumps, Fire Detection And Suppression System, Etc Are Used .
THANK YOU

Central Gas gathering Station of oil india limites

  • 1.
    PRESENTATION ON INDUSTRIAL VISIT TO OIL INDIALIMITED CGGS AND OFF-TAKE POINT MADHUBAN DEPARTMENT OF PETROLUEM TECHNOLOGY DIBRUGARH UNIVERSITY Presented To: Department Of Petroleum Technology Presented By: Students of 1st Semester Oil Well Drilling Technology Batch (2024-2025)
  • 2.
    ACKNOWLEDGEMENT: We Extend OurHeartfelt Gratitude To Dr. Pradip Borgohain, Professor And Head Of The Department Of Petroleum Technology; Dr. (Mrs.) Subrata Borgohain Gogoi, Professor And Dean Of The Faculty Of Earth, Sciences, And Energy; Dr. Ranjan Phukan, Assistant Professor; Dr. Dhrubajyoti Neog, Assistant Professor; Dr. Borkha Mech, Assistant Professor; And Dr. Himanta Borgohain, Assistant Professor, All From The Department Of Petroleum Technology, Dibrugarh University, For Organizing A One-day Industrial Visit To The CGGS Facility Of Oil India Limited, Duliajan. As Part Of Our Course Curriculum. We Also Wish To Express Our Sincere Appreciation To Mr. Pankaj Kumar Das, Installation Manager; Mr. ------------, ---; And The Entire Team Of CGGS At Oil India Limited For Their Guidance And For Providing An Insightful Demonstration Of The Various Technical Aspects And Equipment At The Well Site. Their Dedication And Hospitality Played A Pivotal Role In Making This Industrial Visit A Remarkable Success. The Opportunity To Gain Hands-on Exposure To The Operations At CGGS Was An Invaluable And Enlightening Experience For All Of Us. Regards: Batch (2024-2025), 1st Semester Oil Well Drilling Technology
  • 3.
    CONTENT:  INTRODUCTION  OVERALLLAYOUT DIAGRAM OF CGGS  GAS FLOW DIAGRAM  GAS MEASUREMENTS SYSTEM  SAFETY MEASURES  CONCLUSION
  • 4.
    INTRODUCTION:  CGGS IsConstructed In Madhuban Near Well NHK#50, At A Distance Of 6km From Duliajan, Dibrugarh District.  Constructed To Supply 6mmscmd Of Natural Gas Containing Atleast 7% C2 + Components To BCPL From A Single Point.  There Are 9 Incoming Lines From Different Fields.  Gas Handling Capacity 12.50 MMSCMD.  Natural Gas Liquid Handling Capacity 1250 KLPD.
  • 5.
  • 6.
  • 7.
    LP Indirect BathHeater • Used for variety of purpose • Usually for heating Natural Gas • Works as a dual fuel burner for Natural Gas and LPG • Enter in a heated bath before entering LP Seperator
  • 8.
    Heater Treater • Itis 3 phase separator vessel • Helps to utilise heat and mechanical separation • Facilates the separation of oil water emulsion before transporting the dry oil thorugh pipeline • Heater Treater consists of 3 Section  Degasing  Heating  Differential Oil Control
  • 9.
  • 10.
    A Finger-type SlugCatchers is specialized slug catching system that uses a series of long, horizontal pipes (referred to as “fingers”) to handle and separate slugs in a pipeline.
  • 11.
  • 12.
    GAS MEASUREMENTS SYSTEM: GasMeasurement System Ultrasonic Flowmeters And Gas Chromatographs Are Essential Tools In Gas Measurement Systems  An Ultrasonic Flowmeter Is Increasingly Used In Custody Transfer Applications.  Gas Chromatograph Is Used For Flow & Energy Measurement And Quality Monitoring Of Gas
  • 13.
    SAFETY MEASURES: 1. FirewaterSystem in the Oil and Gas Industry:  Firewater Pumps  Jockey Pump  Firewater Network  Hydrants and Monitors  Sprinklers 2. Fire Detection and Suppression System:  Smoke Detectors  Heat Detectors  Gas Detectors  Gas Based System  Foam Based System  Powder Based System
  • 14.
    3. The AFFF(Aqueous Film Foaming Foam):  Foam Concentrate  Foam Proportioner  Foam Pourers  Foam Generator  Storage Tank  Water Supply System  Control Panel  Detection And Activation 4. Emergency Shutdown (ESD) System:  Process Isolation  Equipment Shutdown  Emergency Venting  Fire And Gas Detection Integration
  • 15.
  • 16.
    CONCLUSION:  CGGS WasInitially Envisioned To Supply 6 MMSCFD Of Rich Gas To BCPL .  BCPL Consumes 1.35 MMSCFD And Returns 4.65 Mmscfd .  Oil Also Supplies Gas To Bvfcl , Neepco , Apgcl , Nrl , Apl , Ioc-aod , Tea Grids , Small Industries And Png .  The Facility Features Slug Catchers , Kod , Filter Seperator, Headers , Oil Water Separator , Effluent Treatment Plant , Condensate Tank , Flare System , Ultrasonic Flowmeters And Gas Chromatographs .  Safety Is The Topmost Priority In Any Industrial Plant . Safety Features Like Smoke Detectors, Esd, Fire Water Pumps, Fire Detection And Suppression System, Etc Are Used .
  • 17.