Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Fuji tu dong hoa catalog frenic-aqua-fuji-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
The document describes the Beijer Electronics HVAC Inverter H2, which provides energy efficient control of fans and pumps for HVAC and other industrial applications. It has a built-in PID controller and optional communication boards, and is available in frame sizes from 0.75-160 kW. It offers features like manual/auto control selection, integrated EMC filtering, plug-in control terminals, and an OLED display.
Automation of hydraulic structures like dams and trash racks can provide several benefits. Dams can be automated to control gates and issue alerts based on water levels detected by sensors. A microcontroller monitors water levels and opens gates in steps to regulate water flow. When upper gates open, text alerts are sent to authorities. Trash racks can also be automated using sensors and machines to continuously clean debris. Overall, automation improves efficiency, reduces human errors and hazards, and allows remote or continuous monitoring of hydraulic infrastructure.
Catalog biến tần Frenic eHVAC - beeteco.com
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
Catalog Frenic-HVAC (Fuji Electric): Biến tần Frenic-HVAC
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic ACE Mini
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Catalog Biến tần Frenic Aqua Fuji-Beeteco.comBeeteco
The document discusses Fuji Electric's FRENIC-AQUA series of inverters. It provides high-performance control of pumps and blowers for water and wastewater applications through energy saving functions and dedicated control features. These inverters contribute to cost reduction by optimizing processes and cutting power consumption for water treatment facilities. The inverters have a slim body design and user-friendly interface to allow independent installation and easy operation and maintenance.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Fuji tu dong hoa catalog frenic-aqua-fuji-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
The document describes the Beijer Electronics HVAC Inverter H2, which provides energy efficient control of fans and pumps for HVAC and other industrial applications. It has a built-in PID controller and optional communication boards, and is available in frame sizes from 0.75-160 kW. It offers features like manual/auto control selection, integrated EMC filtering, plug-in control terminals, and an OLED display.
Automation of hydraulic structures like dams and trash racks can provide several benefits. Dams can be automated to control gates and issue alerts based on water levels detected by sensors. A microcontroller monitors water levels and opens gates in steps to regulate water flow. When upper gates open, text alerts are sent to authorities. Trash racks can also be automated using sensors and machines to continuously clean debris. Overall, automation improves efficiency, reduces human errors and hazards, and allows remote or continuous monitoring of hydraulic infrastructure.
Catalog biến tần Frenic eHVAC - beeteco.com
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
Catalog Frenic-HVAC (Fuji Electric): Biến tần Frenic-HVAC
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic ACE Mini
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Catalog Biến tần Frenic Aqua Fuji-Beeteco.comBeeteco
The document discusses Fuji Electric's FRENIC-AQUA series of inverters. It provides high-performance control of pumps and blowers for water and wastewater applications through energy saving functions and dedicated control features. These inverters contribute to cost reduction by optimizing processes and cutting power consumption for water treatment facilities. The inverters have a slim body design and user-friendly interface to allow independent installation and easy operation and maintenance.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Catalog Biến tần Frenic 5000g11 Fuji Electric
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
This document provides a catalog of agricultural products from Dickey-john, including:
- Precision controllers for application of materials, with options for single-channel, dual-channel, and variable-rate control.
- Sensors for monitoring application rates, ground speed, hopper levels, and more.
- Moisture testers for measuring soil and seed moisture.
- Components for the IntelliAg precision farming system, including terminals, modules, and accessories to monitor and control planters, sprayers and other equipment.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Catalog biến tần Frenic Mega Fuji Electric-Beeteco.comBeeteco
The document describes Fuji Electric's FRENIC-MEGA inverter. It has been developed to support a wide range of applications with improved performance, functionality, environmental awareness, and easy maintenance compared to previous models. Key features highlighted include improved acceleration and overload capabilities, enhanced response time, expanded brake circuit capacity, and various functions to accommodate different needs.
This document discusses the history and applications of automation. It covers various types of automation including home, building, office, mobility, and industrial automation. It provides examples of automation technologies like CNC machines and 3D printing. It also discusses levels of automation from basic mechanization to fully cognitive systems. Reasons for automating include increased productivity and reduced costs. Potential challenges of automation include reduced workforce and unemployment. The document looks at emerging technologies like Industry 4.0, the Internet of Things, wearable devices, and autonomous vehicles that are increasing automation.
Microcontrollers are used in washing machines to digitally control operations like timing profiles, motor speed, water temperature and flow rate. They allow for easier control of the machine compared to analog knobs. The microcontroller monitors input states selected by the user and uses analog inputs to compare temperature and output signals to vary motors and water flow accordingly. It efficiently controls torque and water levels for different load sizes.
The document describes a commercial heating, ventilation, and air conditioning (HVAC) system called SDHV (Small-Duct High-Velocity) that uses very small ducts to deliver conditioned air into rooms. The system provides even temperatures throughout spaces using quiet jets of air without drafts. It also offers energy efficiency and design flexibility to heat, cool, ventilate, and condition multiple zones using different equipment options. The document includes specifications for Unico HVAC air handlers and blower modules that are compatible with the SDHV small-duct system.
Fuji tu dong hoa catalog frenic-hvac-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
Simulation of Automatic Water Level Control System by using Programmable Logi...ijtsrd
This research focuses on the design and implementation of a PLC based water level control system. In this research, there are three primary objectives the water level indicator circuit design, manual control system of water level control and the PLC based automatic water level control. Float switches cannot be able to use to indicate the multi water level in the desired control system. Therefore, AND gate based digital electronic water sensor is invented and used in this proposed not only manual water level control but also PLC based automatic water level control by dividing in eight steps. Induction motor is used to drive the pump as a one set package. So, induction motor starting method is selected according to the power rating of motor, type of motor and nature of application. Star delta starting method is used to reduce the starting current of induction motor. For PLC based automatic water level control, Siemens S7 1200 PLC is used to control the desire water level. There are 10 inputs and 10 outputs in the proposed automatic water level control. Ladder diagram programming is used for this control. Mrs Yin Yin Mon | Mrs Win Moet Moet Htwe | Mrs Khin Ei Ei Khine ""Simulation of Automatic Water Level Control System by using Programmable Logic Controller"" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-4 , June 2019, URL: https://www.ijtsrd.com/papers/ijtsrd25172.pdf
Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/25172/simulation-of-automatic-water-level-control-system-by-using-programmable-logic-controller/mrs-yin-yin-mon
Prototype for automatically navigated water irrigation systemtheijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
Mitsubishi inverter freqrol-d700 series dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
The document discusses the Distributed Control System (DCS) at IFFCO Phulpur, located near Prayagraj, India. The IFFCO Phulpur facility produces ammonia and urea and has a production capacity of 0.824 MTPA for ammonia and 1.416 MTPA for urea, as well as other fertilizers. A DCS is a specially designed control system used to control large, complex industrial processes through distributed controllers connected by communication networks. The key components of a DCS include field devices, input/output modules, controllers located near field devices, a human-machine interface, and control engineering workstations.
Siemens Terminal Box Controller (APOGEE Automation System )CONTROLS & SYSTEMS
The document describes the Siemens Terminal Box Controller, which provides direct digital control for variable air volume HVAC systems. The controller can operate independently or as part of the APOGEE Automation System to control various HVAC applications. It interfaces with sensors, actuators, and the Portable Operator's Terminal for monitoring and configuration. Key features include PID control, unique control algorithms, HVAC diagnostics, and energy management capabilities.
The document discusses supervisory control and data acquisition (SCADA) systems. It defines SCADA and provides a brief history. It describes common SCADA components like remote terminal units (RTU), programmable logic controllers (PLC), human-machine interfaces, and data acquisition servers. It discusses the system components, future trends moving to networked systems, and applications in power system automation including intelligent electronic devices and automation processes. It concludes that India is moving towards greater power grid automation for increased efficiency and standardization.
The FlexStat is an intelligent thermostat/controller that provides flexible control over indoor environmental quality (IEQ) without a large building automation system. It simplifies networked zone control for HVAC equipment. The FlexStat has a built-in library of control applications that can be selected from menus, including applications for air handling units, fan coil units, heat pumps, and roof top units. It also features temperature, humidity, motion, and CO2 sensing as well as configurable inputs, outputs, scheduling, and alarms.
Industrial monitoring and control systems using andriod applicationAvinash Vemula
Automation takes the complete control of total plants few authentication and manual actions are needed from user side for completing action .Hence there is a must situation for users presence at all times in the control for taking some timely needed control actions. The proposed system provides a good solution to this problem. The whole control room environment is additionally implemented in the arm-android platform and the same is communicated to the process through Bluetooth. Now the user in control can use mobile at anytime, anywhere to monitor and control the whole plant.8051 is used here for acquiring process control parameters from the sensors like temperature, gas etc and transmitting it via a Bluetooth module to an android device. Hence the parameter values can be monitored and stored simultaneously.
Supervisory control and data acquisition (SCADA) is a control system architecture comprising computers, networked data communications and graphical user interfaces(GUI) for high-level process supervisory management, while also comprising other peripheral devices like programmable logic controllers (PLC) and discrete proportional-integral-derivative (PID) controllers to interface with process plant or machinery. The use of SCADA has been considered also for management and operations of project-driven-process in construction.
PID is short for "proportional plus integral and derivative", three algorithm components used by this type of controller in managing a control loop. Process loop controllers use one, two or all three of these to optimally control the process system. PID control is used in a wide variety of applications in industrial control and process system management.
Fuji tu dong hoa catalog inverter-frenic-lift-fuji-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem thêm tại: http://haophuong.com
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Catalog Biến tần Frenic 5000g11 Fuji Electric
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
This document provides a catalog of agricultural products from Dickey-john, including:
- Precision controllers for application of materials, with options for single-channel, dual-channel, and variable-rate control.
- Sensors for monitoring application rates, ground speed, hopper levels, and more.
- Moisture testers for measuring soil and seed moisture.
- Components for the IntelliAg precision farming system, including terminals, modules, and accessories to monitor and control planters, sprayers and other equipment.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Catalog biến tần Frenic Mega Fuji Electric-Beeteco.comBeeteco
The document describes Fuji Electric's FRENIC-MEGA inverter. It has been developed to support a wide range of applications with improved performance, functionality, environmental awareness, and easy maintenance compared to previous models. Key features highlighted include improved acceleration and overload capabilities, enhanced response time, expanded brake circuit capacity, and various functions to accommodate different needs.
This document discusses the history and applications of automation. It covers various types of automation including home, building, office, mobility, and industrial automation. It provides examples of automation technologies like CNC machines and 3D printing. It also discusses levels of automation from basic mechanization to fully cognitive systems. Reasons for automating include increased productivity and reduced costs. Potential challenges of automation include reduced workforce and unemployment. The document looks at emerging technologies like Industry 4.0, the Internet of Things, wearable devices, and autonomous vehicles that are increasing automation.
Microcontrollers are used in washing machines to digitally control operations like timing profiles, motor speed, water temperature and flow rate. They allow for easier control of the machine compared to analog knobs. The microcontroller monitors input states selected by the user and uses analog inputs to compare temperature and output signals to vary motors and water flow accordingly. It efficiently controls torque and water levels for different load sizes.
The document describes a commercial heating, ventilation, and air conditioning (HVAC) system called SDHV (Small-Duct High-Velocity) that uses very small ducts to deliver conditioned air into rooms. The system provides even temperatures throughout spaces using quiet jets of air without drafts. It also offers energy efficiency and design flexibility to heat, cool, ventilate, and condition multiple zones using different equipment options. The document includes specifications for Unico HVAC air handlers and blower modules that are compatible with the SDHV small-duct system.
Fuji tu dong hoa catalog frenic-hvac-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
Simulation of Automatic Water Level Control System by using Programmable Logi...ijtsrd
This research focuses on the design and implementation of a PLC based water level control system. In this research, there are three primary objectives the water level indicator circuit design, manual control system of water level control and the PLC based automatic water level control. Float switches cannot be able to use to indicate the multi water level in the desired control system. Therefore, AND gate based digital electronic water sensor is invented and used in this proposed not only manual water level control but also PLC based automatic water level control by dividing in eight steps. Induction motor is used to drive the pump as a one set package. So, induction motor starting method is selected according to the power rating of motor, type of motor and nature of application. Star delta starting method is used to reduce the starting current of induction motor. For PLC based automatic water level control, Siemens S7 1200 PLC is used to control the desire water level. There are 10 inputs and 10 outputs in the proposed automatic water level control. Ladder diagram programming is used for this control. Mrs Yin Yin Mon | Mrs Win Moet Moet Htwe | Mrs Khin Ei Ei Khine ""Simulation of Automatic Water Level Control System by using Programmable Logic Controller"" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-4 , June 2019, URL: https://www.ijtsrd.com/papers/ijtsrd25172.pdf
Paper URL: https://www.ijtsrd.com/engineering/electrical-engineering/25172/simulation-of-automatic-water-level-control-system-by-using-programmable-logic-controller/mrs-yin-yin-mon
Prototype for automatically navigated water irrigation systemtheijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
Mitsubishi inverter freqrol-d700 series dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
The document discusses the Distributed Control System (DCS) at IFFCO Phulpur, located near Prayagraj, India. The IFFCO Phulpur facility produces ammonia and urea and has a production capacity of 0.824 MTPA for ammonia and 1.416 MTPA for urea, as well as other fertilizers. A DCS is a specially designed control system used to control large, complex industrial processes through distributed controllers connected by communication networks. The key components of a DCS include field devices, input/output modules, controllers located near field devices, a human-machine interface, and control engineering workstations.
Siemens Terminal Box Controller (APOGEE Automation System )CONTROLS & SYSTEMS
The document describes the Siemens Terminal Box Controller, which provides direct digital control for variable air volume HVAC systems. The controller can operate independently or as part of the APOGEE Automation System to control various HVAC applications. It interfaces with sensors, actuators, and the Portable Operator's Terminal for monitoring and configuration. Key features include PID control, unique control algorithms, HVAC diagnostics, and energy management capabilities.
The document discusses supervisory control and data acquisition (SCADA) systems. It defines SCADA and provides a brief history. It describes common SCADA components like remote terminal units (RTU), programmable logic controllers (PLC), human-machine interfaces, and data acquisition servers. It discusses the system components, future trends moving to networked systems, and applications in power system automation including intelligent electronic devices and automation processes. It concludes that India is moving towards greater power grid automation for increased efficiency and standardization.
The FlexStat is an intelligent thermostat/controller that provides flexible control over indoor environmental quality (IEQ) without a large building automation system. It simplifies networked zone control for HVAC equipment. The FlexStat has a built-in library of control applications that can be selected from menus, including applications for air handling units, fan coil units, heat pumps, and roof top units. It also features temperature, humidity, motion, and CO2 sensing as well as configurable inputs, outputs, scheduling, and alarms.
Industrial monitoring and control systems using andriod applicationAvinash Vemula
Automation takes the complete control of total plants few authentication and manual actions are needed from user side for completing action .Hence there is a must situation for users presence at all times in the control for taking some timely needed control actions. The proposed system provides a good solution to this problem. The whole control room environment is additionally implemented in the arm-android platform and the same is communicated to the process through Bluetooth. Now the user in control can use mobile at anytime, anywhere to monitor and control the whole plant.8051 is used here for acquiring process control parameters from the sensors like temperature, gas etc and transmitting it via a Bluetooth module to an android device. Hence the parameter values can be monitored and stored simultaneously.
Supervisory control and data acquisition (SCADA) is a control system architecture comprising computers, networked data communications and graphical user interfaces(GUI) for high-level process supervisory management, while also comprising other peripheral devices like programmable logic controllers (PLC) and discrete proportional-integral-derivative (PID) controllers to interface with process plant or machinery. The use of SCADA has been considered also for management and operations of project-driven-process in construction.
PID is short for "proportional plus integral and derivative", three algorithm components used by this type of controller in managing a control loop. Process loop controllers use one, two or all three of these to optimally control the process system. PID control is used in a wide variety of applications in industrial control and process system management.
Fuji tu dong hoa catalog inverter-frenic-lift-fuji-dienhathe.orgDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.vn
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem thêm tại: http://haophuong.com
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
This high performance vector control inverter has complete control over speed and torque. It provides industry-leading control performance through highly accurate speed control, fast response times, and precise torque control. The inverter is available in a wide range of capacities to support flexible applications globally.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
This document provides information on Fuji Electric's new FRENIC-Mini compact inverter. Key details include:
- The FRENIC-Mini offers high performance control of motors and equipment in a compact package with simple operation and global compatibility.
- It has rich functionality, compact design, easy operation/maintenance, and compatibility with existing Fuji products and networks.
- Specifications include voltage and frequency ranges, overload capabilities, enclosure type, cooling method, and applicable motor ratings from 0.1 to 3.7 kW.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng IDEC IZUMI: đèn báo nút nhấn, relay, timer, PLC, màn hình idec...www.haophuong.com
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng IDEC IZUMI: đèn báo nút nhấn, relay, timer, PLC, màn hình idec...www.haophuong.com
Công ty TNHH Hạo Phương chuyên cung cấp các thiết bị: Đèn báo, nút nhấn, Relay, Timer, Contactor, MCCB, ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới như Fuji, kansai, honeywell, Circutor, IDEC
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, Biến tần .... Từ các thương hiệu hàng đầu trên thế giới như Fuji Electric. IDEC IZUMI, Kansai, Takigen, Circutor,
Catalog thiết bị đóng cắt Fuji Electric - 05 - Limit Switch
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
10 - Ac Power Regulators & Control Power Transformers - Fuji ElectricCTY TNHH HẠO PHƯƠNG
Catalog thiết bị đóng cắt Fuji Electric - 10 - Ac Power Regulators & Control Power Transformers
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
Catalog thiết bị đóng cắt Fuji Electric - 08 - Circuit Protector
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
Catalog thiết bị đóng cắt Fuji Electric - 04 - Driver Components
*********************************************************************
CTY TNHH HẠO PHƯƠNG - Nhà phân phối chính thức các thiết bị điện công nghiệp và tự động hóa của hãng FUJI ELECTRIC JAPAN tại Việt Nam
Xem chi tiết các sản phẩm Fuji Electric tại
http://haophuong.com/b1033533/fuji-electric
HYDROVAR from Xylem is an intelligent pump controller that matches pump performance to demand. It controls the speed of standard IEC motors, allowing energy savings of up to 70% compared to fixed speed pumps. The 5th generation HYDROVAR offers improved robustness, security, and performance over previous generations. It is easy to commission and operate, and provides control functions like constant pressure or flow as well as integrated protections for the pump and motor.
Lenze makes many things FAST & EASY for you.
With our motivated and committed approach, we work together with you to create the best possible solution and set your ideas in motion - whether you are looking to optimise an existing machine or develop a new one. We always strive to make things easy and seek perfection therein. This is anchored in our thinking, in our services and
in every detail of our products. It's as easy as that!
I will always be very pleased to answer questions and provide information. BUT ... did you know Lenze has a GLOBAL PRESENCE?
So, for more information in your own language, you are also able to contact our local branch. (see www.lenze.com/en/about-lenze/global-presence/)
OR ... for a personal introduction, please either drop me a line or give me a call and I will arrange for a local colleague to contact you:
e-mail: derek.jones@lenze.com
Tel: +44 1234 753216
VLT® Micro Drive is a genuine VLT® frequency converter with unsurpassed reliability, user-friendliness, condensed functionality, and extremely easy to commission. Terminal numbers are named in the same manner as in the rest of the VLT® family. It’s developed and manufactured by Danfoss Drives, the leading drives experts since 1968 and creators of VLT® – The Real Drive. For more info, visit http://www.danfoss.in/
Mitsubishi inverter freqrol-d700 seriesDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi inverter freqrol-d700 seriesDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Energy conservation security and complete automationKishorKhandge1
Automation will turn on and off the fan and lights with the help of timers and counter sensors which will save energy.
Energy saving is a need of the hour
With the help of automation we can make security
With the help of automation we can turn the motor on or off if the water in the water tank is low the motor will start and shut off after filling the water tank which will save both energy and water
ZH/PVII Series UPS 10-600kVA from HRD UPS -20160303Wendy Zhang
The document introduces two series of UPS systems - the ZH Series Online HF UPS from 15-400kVA and the Powervalue (II) Series LF UPS from 10kVA-600kVA 3:3phase with output isolation transformer. Key features of the ZH Series include its high efficiency mode, true reliability, compact design, flexible installation options, and automatic battery management. The Powervalue (II) Series is highly reliable with an output isolation transformer, features intelligent digital control, handles unbalanced loads, includes intelligent battery management, and allows for parallel capabilities.
This document provides information on Midea's 3 phase, 380-415V, 50Hz V4 Plus K Series VRF system, including:
- It describes the system's high efficiency features such as its brushless DC inverter compressor, DC fan motor, and optimized heat exchanger design.
- It lists the outdoor unit models and their capacities ranging from 8HP to 72HP. It also provides an indoor unit lineup and details on piping and installation specifications.
- Sections cover the flexible and reliable design of the system, including automatic addressing of indoor units, oil return technology, soft start, and convenient maintenance functions.
The document describes DEIF's hydro control technology and products for hydro power plants. It discusses DEIF's headquarters in Skive, Denmark where they centralize production, R&D, testing, training and shipping. It then outlines their global sales and support network. The document proceeds to describe DEIF's controller solutions for hydro projects, including the DM-400 integrated controller. It provides an example application of the DM-400 controlling a Pelton turbine and discusses its functions. Finally, it summarizes DEIF products for mini, small and large hydro applications, including the GPC-3 controller for valve control in mini hydro plants.
Explore the compact inverter WJ200 series built for excellent performance and user-friendliness.
To learn more about Hitachi Inverters, visit: https://www.hitachi-iesa.com/ac-drives-inverters
Implementation of slow down and stop system:
• PDS system needs to be connected to engine protection system
• Parts needed for slow down and stop system
• Electronic floor mounted pedal
• Electronic control unit
• Electronic actuator
This document introduces RealForce Power's product lines in solar PV and lithium-ion battery applications. It provides an overview of their product offerings, including PV modules and battery energy storage systems. Their battery storage systems include lithium-ion battery packs, a battery management system, power conversion system, monitoring system, and other components housed in a portable container design. The storage systems can provide grid-connected and off-grid power and have functions like automatic grid charging, power dispatching, reactive power support, and protective features.
Efore DC backup SYSTEM, Master Portfolio 2016, uninterruptible power supplyEFORE Group
1) The document provides information on DC backup power system products from Efore, including modules, racks, cabinets, and their technical specifications and features.
2) It highlights the flexible and reliable nature of Efore's modular DC power solutions and their ability to provide continuous backup power in various applications and environments.
3) The document showcases how Efore's products like rectifiers, inverters, controllers, and monitoring modules work together in an integrated DC power system to ensure uninterrupted power supply.
The document provides information on Ingeteam's INGEDRIVETM family of low- and medium-voltage variable speed drives. It describes the drives' modular design, control system, power ratings up to 36 MVA, cooling options, safety features, communication capabilities, and applications in industries such as marine, oil & gas, metals, mining, and water & waste water. The document also includes specifications, dimensions, and type codes for some example drive models.
BTech ECE project final report using ArduinoBhuvi85107
This is my original work. The notes I have made on some pages were learnt over time, you can incorporate them in your electronics hobbying (although this site is mostly used for copying projects and not learning haha). Feel free to use any part of the project.
This document provides an overview of NTPC Limited, the largest power company in India, and Badarpur Thermal Power Station (BTPS) located in New Delhi. It discusses NTPC's history and installed capacity. For BTPS, it describes the plant's establishment, units, and power distribution network. The document then explains BTPS's coal-based power generation process and the roles of its control instrumentation and data acquisition systems in operation and maintenance. It also discusses components like LVDTs, PLCs, and memory management in data collection and control.
The miniMUST 1090 is a scalable, hot-swappable true online double conversion modular UPS system that provides reliable backup power for data centers, servers, industrial automation equipment, and other critical applications. It uses 10PMX and 15PMX power modules that are available in various chassis configurations from 2 to 6 modules. The miniMUST 1090 offers flexible voltage and frequency settings, integrated battery backup, and remote monitoring via a touchscreen display.
IRJET-Smart System for Food Industries and BakeriesIRJET Journal
This document proposes a smart system for food industries and bakeries that automates processes using a programmable logic controller (PLC). Currently, baking and cooling processes are done manually, which is time-consuming and poses risks to workers near high-heat areas. The proposed system uses sensors like an IR sensor and temperature sensor connected to a PLC to automate conveyance of food trays, opening/closing of oven doors, oven temperature control, and activation of cooling fans. This allows baking to be done safely, efficiently and with less waste by minimizing human intervention and risks through automation controlled by the PLC.
This document summarizes Midea's VRF product portfolio, including their DC inverter and partial inverter VRF systems, indoor unit options, and key features. It highlights that Midea offers the largest VRF system capacities available with a single unit capacity of 22HP and a combination capacity of 88HP. It also emphasizes their systems' high efficiency, reliable refrigerant control technology, quality certifications, and flexible installation and control capabilities.
Similar to catalog Frenic AQUA catalog - www.haophuong.com (20)
Hạo Phương xin giới thiệu đến quý khách hàng cách cài đặt cơ bản dòng biến tần MD290. Biến tần Inovance MD290 là dòng sản phẩm đa năng rất dễ sử dụng và đem lại hiệu quả cho việc điều khiển tốc độ động cơ và các ứng dụng đặc biệt khác. Biến tần Inovance MD290 dùng cho các ứng dụng: điều khiển băng tải, bơm chân không kiểu piston, vận chuyển vật liệu, máy chế biến gỗ,…
Hạo Phương xin giới thiệu đến quý khách hàng cách cài đặt cơ bản dòng biến tần MD290. Biến tần Inovance MD290 là dòng sản phẩm đa năng rất dễ sử dụng và đem lại hiệu quả cho việc điều khiển tốc độ động cơ và các ứng dụng đặc biệt khác. Biến tần Inovance MD290 dùng cho các ứng dụng: điều khiển băng tải, bơm chân không kiểu piston, vận chuyển vật liệu, cắt, máy chế biến gỗ,...
This document announces the discontinuation of several control unit products from IDEC Corporation. It provides details on products being discontinued, their recommended replacements, and last order and delivery dates. Key products being discontinued include LED illuminated white colored products, control units with 6V AC/DC illumination ratings, some emergency stop switches and selector switches, and other low selling items. Replacements or last order dates are provided for most discontinued products.
Những lưu ý khi sử dụng máy lọc nước tại vòi Cleansui CSP601CTY TNHH HẠO PHƯƠNG
Bạn vừa mới mua sản phẩm máy lọc nước tại vòi Cleansui CSP601, và lo lắng không biết sử dụng như thế nào đúng cách. Dưới đây là một số lưu ý mà chúng tôi đưa ra giúp bạn đảm bảo an toàn cũng như là đảm bảo nguồn nước sạch khi sử dụng sản phẩm.
Beeteco xin gửi đến quý khách bảng giá biến tần Inovance mới nhất 2020 bao gồm giá chi tiết của các dòng sản phẩm:
Biến tần Inovance MD200
Biến tần Inovance MD290
Biến tần Inovance MD310
Biến tần Inovance MD500
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Inovance MD500. Catalog chứa đầy đủ thông tin về sản phẩm, kích thước và những lưu ý để sử dụng thiết bị hiệu quả.
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
The document is a user guide for the MD310 AC drive from Shenzhen Inovance Technology Co., Ltd. It provides information on product specifications, wiring, setup, troubleshooting, and parameters. The guide covers safety precautions, nameplate details, terminal descriptions, typical wiring diagrams, easy setup instructions, fault solutions, and tables of general and monitoring parameters.
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Inovance MD290. Catalog chứa đầy đủ thông tin về sản phẩm, kích thước và những lưu ý để sử dụng thiết bị hiệu quả.
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
This document provides product information for MD200 AC drives, including:
- General specifications such as dimensions, voltage classes, power ratings, and carrier frequencies for different models.
- Technical specifications covering control modes, overload capacity, V/F curves, acceleration/deceleration profiles, and DC braking functions.
- Nameplate information including model numbering conventions and certification markings.
Beeteco xin gửi đến quý khách hàng Catalog biến tần Inovance dòng MD500 với đầy đủ thông tin về sản phẩm, kích thước, những lưu ý để sử dụng thiết bị hiệu quả.
Contact:
Trụ sở TP.HCM: Số 139-141 đường Phú Châu, Kp. 1, P. Tam Bình, Q. Thủ Đức, Tp. Hồ Chí Minh
Tel: (028) 3636 5671|2|3 - Fax: (028) 3636 5674
Trụ sở Hà Nội: P502 tầng 5, tòa VP số 15 ngõ 2, Phố Thọ Tháp,P. Dịch Vọng, Q. Cầu Giấy, Hà Nội
Tel: (024) 320 11 408 | 320 11 410
Email: contact@beeteco.com - MST: 3702357207
Beeteco xin gửi đến quý khách hàng Catalog biến tần Inovance dòng MD310 với đầy đủ thông tin về sản phẩm, kích thước, những lưu ý để sử dụng thiết bị hiệu quả.
The document provides instructions for using an AC drive product from Inovance. It includes information about nameplate and model number, components, technical specifications, dimensions, system connections, installation, wiring, operation, maintenance and safety precautions. The document is the user guide for Inovance MD290 series AC drives for power ratings between 500-630 kW.
Beeteco xin gửi đến quý khách hàng Catalog biến tần Inovance dòng MD200 với đầy đủ thông tin về sản phẩm, kích thước, những lưu ý để sử dụng thiết bị hiệu quả.
Biến tần Inovance là dòng sản phẩm đa năng rất dễ sử dụng và đem lại hiệu quả cho việc điều khiển tốc độ động cơ và các ứng dụng đặc biệt khác. Biến tần Inovance MD200 dùng cho các ứng dụng: điều khiển băng tải, bơm chân không kiểu piston, vận chuyển vật liệu, cắt, máy chế biến gỗ,...
Thông tin liên hệ:
Trụ sở TP.HCM: Số 139-141 đường Phú Châu, Kp. 1, P. Tam Bình, Q. Thủ Đức, Tp. Hồ Chí Minh
Tel: (028) 3636 5671|2|3 - Fax: (028) 3636 5674
Trụ sở Hà Nội: P502 tầng 5, tòa VP số 15 ngõ 2, Phố Thọ Tháp, P. Dịch Vọng, Q. Cầu Giấy, Hà Nội
Tel: (024) 320 11 408 | 320 11 410
Email: contact@beeteco.com - MST: 3702357207
Beeteco gửi đến quý khách hàng catalog thiết bị điện của thương hiệu Vteke. Catalog chứa đầy đủ thông tin về sản phẩm, kích thước và những lưu ý để sử dụng thiết bị hiệu quả.
=========================================
Beeteco.com@ Công ty TNHH Thương Mại Kỹ Thuật ASTER
Hotline: 0909.41.61.43
Email: contact@beeteco.com
Fanpage: www.facebook.com/beeteco
Địa chỉ: 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương.
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
Quý khách có nhu cầu mua hàng hoặc hợp tác cùng chúng tôi xin vui lòng liên hệ theo địa chỉ :
CÔNG TY CỔ PHẦN HẠO PHƯƠNG
Trụ sở chính:
Địa chỉ: Số 88 đường Vĩnh Phú 40, Kp. Hòa Long, P. Vĩnh Phú, Thuận An, Bình Dương.
Văn phòng Hà Nội:
Địa chỉ: Số 95 TT4 – KĐT Mỹ Đình Sông Đà – Phường Mỹ Đình – Q. Nam Từ Liêm – Hà Nội
Chi nhánh Cambodia:
Địa chỉ: The Park Land SenSok, Borey Chip Mong, House Number 22, P11.Sangkat Phnom Penh Thmey, Khan San Sok, Phnom Penh.
Email: cs@haophuong.com – Website: haophuong.com
Facebook: https://www.facebook.com/haophuongcompany/
HOTLINE: 1800 6547
The document announces that several HG series operator interface products will be discontinued due to parts no longer being available from suppliers. It provides details on the specific products being discontinued, their recommended replacements, and the schedule including last order and delivery dates. Support for maintenance will be available until late 2026 depending on remaining stock. Customers are advised to place final orders by November 2019 to ensure supply of the discontinued products.
Màn hình cảm ứng dòng V9 là sản phẩm của nhà sản xuất Fuji Electric. Với khả năng giao tiếp mạnh mẽ, đáp ứng được yêu cầu trong tất cả các ngành công nghiệp.
HMI Fuji Electric dòng TS là sản phẩm có khả năng giao tiếp mạnh mẽ, TECHNOSHOT đáp ứng được yêu cầu trong tất cả các ngành công nghiệp. Sản phẩm có giao diện được lập trình một cách trực quan nhất, màn hình với độ sắc nét lên đến 64k màu. Tấm nền TFT cho độ sáng cao và có khả năng tái tạo màu tốt.
The BM3RSB- and BM3RHB- series are 32AF manual motor starters that provide adjustable thermal-magnetic trip protection for motors up to 15kW. They have standard breaking capacities of 25-100kA and compact dimensions. Accessories include auxiliary contact blocks, undervoltage trip devices, and enclosures.
A review of the growth of the Israel Genealogy Research Association Database Collection for the last 12 months. Our collection is now passed the 3 million mark and still growing. See which archives have contributed the most. See the different types of records we have, and which years have had records added. You can also see what we have for the future.
How to Build a Module in Odoo 17 Using the Scaffold MethodCeline George
Odoo provides an option for creating a module by using a single line command. By using this command the user can make a whole structure of a module. It is very easy for a beginner to make a module. There is no need to make each file manually. This slide will show how to create a module using the scaffold method.
This presentation was provided by Steph Pollock of The American Psychological Association’s Journals Program, and Damita Snow, of The American Society of Civil Engineers (ASCE), for the initial session of NISO's 2024 Training Series "DEIA in the Scholarly Landscape." Session One: 'Setting Expectations: a DEIA Primer,' was held June 6, 2024.
Strategies for Effective Upskilling is a presentation by Chinwendu Peace in a Your Skill Boost Masterclass organisation by the Excellence Foundation for South Sudan on 08th and 09th June 2024 from 1 PM to 3 PM on each day.
it describes the bony anatomy including the femoral head , acetabulum, labrum . also discusses the capsule , ligaments . muscle that act on the hip joint and the range of motion are outlined. factors affecting hip joint stability and weight transmission through the joint are summarized.
How to Fix the Import Error in the Odoo 17Celine George
An import error occurs when a program fails to import a module or library, disrupting its execution. In languages like Python, this issue arises when the specified module cannot be found or accessed, hindering the program's functionality. Resolving import errors is crucial for maintaining smooth software operation and uninterrupted development processes.
The simplified electron and muon model, Oscillating Spacetime: The Foundation...RitikBhardwaj56
Discover the Simplified Electron and Muon Model: A New Wave-Based Approach to Understanding Particles delves into a groundbreaking theory that presents electrons and muons as rotating soliton waves within oscillating spacetime. Geared towards students, researchers, and science buffs, this book breaks down complex ideas into simple explanations. It covers topics such as electron waves, temporal dynamics, and the implications of this model on particle physics. With clear illustrations and easy-to-follow explanations, readers will gain a new outlook on the universe's fundamental nature.
हिंदी वर्णमाला पीपीटी, hindi alphabet PPT presentation, hindi varnamala PPT, Hindi Varnamala pdf, हिंदी स्वर, हिंदी व्यंजन, sikhiye hindi varnmala, dr. mulla adam ali, hindi language and literature, hindi alphabet with drawing, hindi alphabet pdf, hindi varnamala for childrens, hindi language, hindi varnamala practice for kids, https://www.drmullaadamali.com
LAND USE LAND COVER AND NDVI OF MIRZAPUR DISTRICT, UPRAHUL
This Dissertation explores the particular circumstances of Mirzapur, a region located in the
core of India. Mirzapur, with its varied terrains and abundant biodiversity, offers an optimal
environment for investigating the changes in vegetation cover dynamics. Our study utilizes
advanced technologies such as GIS (Geographic Information Systems) and Remote sensing to
analyze the transformations that have taken place over the course of a decade.
The complex relationship between human activities and the environment has been the focus
of extensive research and worry. As the global community grapples with swift urbanization,
population expansion, and economic progress, the effects on natural ecosystems are becoming
more evident. A crucial element of this impact is the alteration of vegetation cover, which plays a
significant role in maintaining the ecological equilibrium of our planet.Land serves as the foundation for all human activities and provides the necessary materials for
these activities. As the most crucial natural resource, its utilization by humans results in different
'Land uses,' which are determined by both human activities and the physical characteristics of the
land.
The utilization of land is impacted by human needs and environmental factors. In countries
like India, rapid population growth and the emphasis on extensive resource exploitation can lead
to significant land degradation, adversely affecting the region's land cover.
Therefore, human intervention has significantly influenced land use patterns over many
centuries, evolving its structure over time and space. In the present era, these changes have
accelerated due to factors such as agriculture and urbanization. Information regarding land use and
cover is essential for various planning and management tasks related to the Earth's surface,
providing crucial environmental data for scientific, resource management, policy purposes, and
diverse human activities.
Accurate understanding of land use and cover is imperative for the development planning
of any area. Consequently, a wide range of professionals, including earth system scientists, land
and water managers, and urban planners, are interested in obtaining data on land use and cover
changes, conversion trends, and other related patterns. The spatial dimensions of land use and
cover support policymakers and scientists in making well-informed decisions, as alterations in
these patterns indicate shifts in economic and social conditions. Monitoring such changes with the
help of Advanced technologies like Remote Sensing and Geographic Information Systems is
crucial for coordinated efforts across different administrative levels. Advanced technologies like
Remote Sensing and Geographic Information Systems
9
Changes in vegetation cover refer to variations in the distribution, composition, and overall
structure of plant communities across different temporal and spatial scales. These changes can
occur natural.
Main Java[All of the Base Concepts}.docxadhitya5119
This is part 1 of my Java Learning Journey. This Contains Custom methods, classes, constructors, packages, multithreading , try- catch block, finally block and more.
বাংলাদেশের অর্থনৈতিক সমীক্ষা ২০২৪ [Bangladesh Economic Review 2024 Bangla.pdf] কম্পিউটার , ট্যাব ও স্মার্ট ফোন ভার্সন সহ সম্পূর্ণ বাংলা ই-বুক বা pdf বই " সুচিপত্র ...বুকমার্ক মেনু 🔖 ও হাইপার লিংক মেনু 📝👆 যুক্ত ..
আমাদের সবার জন্য খুব খুব গুরুত্বপূর্ণ একটি বই ..বিসিএস, ব্যাংক, ইউনিভার্সিটি ভর্তি ও যে কোন প্রতিযোগিতা মূলক পরীক্ষার জন্য এর খুব ইম্পরট্যান্ট একটি বিষয় ...তাছাড়া বাংলাদেশের সাম্প্রতিক যে কোন ডাটা বা তথ্য এই বইতে পাবেন ...
তাই একজন নাগরিক হিসাবে এই তথ্য গুলো আপনার জানা প্রয়োজন ...।
বিসিএস ও ব্যাংক এর লিখিত পরীক্ষা ...+এছাড়া মাধ্যমিক ও উচ্চমাধ্যমিকের স্টুডেন্টদের জন্য অনেক কাজে আসবে ...
Pride Month Slides 2024 David Douglas School District
catalog Frenic AQUA catalog - www.haophuong.com
1. AQUAHigh performance enabled by the comprehensive use of Fuji technology.
Easy maintenance for the end-user.Maintains safety and protects the
environment.Opens up possibilities for the new generation.
Low voltage AC drives for water, wastewater & irrigation applications
24A1-E-0013
Smile to the Environment
2. Ha Noi Office:
No. 95 - TT4, My Dinh Urban Area,
My Dinh, Nam Tu Liem, Hanoi.
Tel: (84 4) 3568 3740
Fax: (84 4) 3568 3741
Cambodia Office:
#140, Room 1-B, St430, Sangkat Toul
Tompuong II, Khan Chamkamon, PP.
Tel: 855 2322 3635
Fax: 855 2322 3645
Head Office:
No 88, Vinh Phu 40, Hoa Long,
Vinh Phu, Thuan An, Binh Duong.
Tel: (84 650) 37 37 619
Fax: (84 650) 37 37 620
1800 6547
THINK TOGETHER
Nhà phân phối thiết bị điện công nghiệp
hàng đầu Việt Nam
T
3. FRENIC-AQUA
Smile to the Environment
~ Energy Saving for the environment and our children's future ~
2
The first slim-type inverter specialized
in energy-saving from Fuji Electric.
Achieves a great effect on power-saving of
pumps and blowers!
Contributes drastically to cost reduction
by cutting power consumption!
The first slim-type inverter specialized
in energy-saving from Fuji Electric.
Achieves a great effect on power-saving of
pumps and blowers!
Contributes drastically to cost reduction
by cutting power consumption!
The water business market including water purification plants and wastewater plants
has continued to grow in recent years. Using a large volume of water, cost reduction is
required and it largely depends on how efficiently water can be managed. It is of
course achieved by reducing the amount of water to be used, however, the reduction in
power consumption in water transfer and supply also allows significant cost reduction.
And the key to that is the dedicated inverter which controls pumps and motors.
The FRENIC-AQUA series, a Fuji’s new product, helps energy-saving of pumps,
eliminating ineffectual operations by adjusting the amount of water properly to
produce a significant effect both on electricity conservation and on cost reduction.
4. Stand alone
3
Wide variation in model capacity
Optimum control by energy-saving functions
Slim body
Model can be selected from two model types.
Standard type (EMC filter built-in type)
0.75 to 710kW (Protective structure IP21 or IP55 can be selected between 0.75 and 90kW.)
• Linearization function
• Temperature difference constant control and pressure difference constant control
• Energy saving functions including wet-bulb temperature presumption control
• Automatic energy-saving operation
Dedicated pump control function provided as standard
• 4PID control • Cascade control • Mutual operation • Control of maximum starts per hour
• Dry pump detection • Deceleration time for check valve protection • Slow flowrate function
• End of curve detection • Boost function • Acceleration and deceleration at initial stage
• Fire Mode (forced operation) • Customized logic
• Pick-up operation function • Anti-jam
• Torque vector control • Password function
• Real time clock • User friendly, useful key pad
• The inverter can be installed independently; no control panel is required.
The first slim body design among the Fuji
Electric inverters.
The size is the same between IP21 and IP55
(the first in the industry).
User-friendly, useful functions
DCR built-in + EMC filter built-in type
0.75 to 90kW (Protective structure IP21 or IP55 can be selected between 0.75 and 90kW.)
0.75kW to 90kW
110kW to 710kW
Built-in
Built-in
Built-in
External
IP21/IP55
IP00
Inverter capacity EMC filter DC reactor Protective structure
* The models with inverter capacity 45kW to 710kW are coming soon.
5. 4
• Water purification plant and wastewater, clean water and sewage treatment plants
Wide Usage for Water Treatment
Fuji Electric offers high-reliable inverters based on broad ideas focusing on future and with pinpoint
technical support while meeting the complicated needs regarding water treatment that requires stable
water supply and effective use of resources.
FRENIC-AQUA features dedicated functions as standard that are required in water treatment plants, such
as 4PID control, cascade control, dry pump detection, slow flowrate function, and pick-up operation, as
well as many options. These functions contribute strongly to protection of system and reduction of cost.
The pumps and blowers used in water purification, water supply and wastewater treatment plants need
to be controlled with accurate pressure (discharge pressure). FRENIC-AQUA realizes optimal process
control with high-integrity using the built-in PID controller.
The cascade control can control up to eight units + one unit (auxiliary motor), allowing for application
to the large-scale system. In addition, since the operation time of each pump and blower is equalized in
cascade control, the system life can be prolonged.
• Irrigation system
• Seawater desalination
6. 5
FRENIC -AQUA series is equipped with many functions that control the pumps and blowers used in water
treatment facility optimally.
• Pump
• Blower
• Fluid-pressure device
Characteristics in pump usage Advantages
Cost reduction
Longer service life of
the system
Process optimization
Cost cutting
Pump protection
Energy saving
Initial cost cutting
No heater required
Cascade control
(Max. 8 units + 1 unit [auxiliary motor])
(Homogenization of operation hour)
Built-in PID controller
Dry pump detection
Mutual operation
Condensation prevention function
Characteristics in blower usage Advantages
Process optimization
Cost cutting
Energy saving
No heater required
Blower protection
Built-in PID controller
Automatic energy-saving operation
(Energy-saving operation according to load)
Condensation prevention function
Pick-up operation
• Oil pumping system
• Injection machine
• Hydraulic press machine
• Extruders
• Cold and Air Compressors
7. 6
User friendly, easy to see keypad
1. Present value (PV)
2. Setting value (SV)
3. Manipulating value (MV)
4. Frequency
•Possible to set the maximum four timers for a week.
•Possible to set flag holidays (20 days a year).
•Alarm information for last ten times is stored and
displayed with date and time.
•Unit conversion allows you to easily set data.
• Alarm information with date and time
• Unit conversion function between PV and SV values
• Timer function
Real time clock (RTC) is provided as standard.
Japanese
Spanish
Malay
Czech
English
Italian
Vietnamese
Swedish
Chinese
Russian
Thai
Portuguese
German
Greek
Indonesian
Dutch
French
Turkish
Polish
Language
When operation is performed in the
same schedule through a week
When operation schedule varies depending
on the day of the week
24:00:00
18:00:00
12:00:00
06:00:00
00:00:00
Example
Easy failure
analysis
Operation schedule can be set according
to actual condition by using four timers.
• The regulator is indicated by enlarging the LCD.
Optimal Structure Design
*Possible to show understandable indications through the unit conversion function.
*Multi-language function: 19 languages + user customized language supported
5. Output current
6. Output voltage
7. Torque
8. Rotation speed
9. Power consumption
10. Cumulative energy
• Multi-language supported: 19 languages + user customized language (Planned)
No conversion
m3
/h
kPa
in-wg
PSI
%
˚C
mWG
psi
RPM
mbar
mmHg
˚F
l/min
bar
kW
ppm
Unit conversion
Function Units
24:00:00
18:00:00
12:00:00
06:00:00
00:00:00
MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN
8. 7
Multi-language supported, HELP function featured, unit
setting with SV and PV values, data copy (three kinds),
detachable and can be attached on the panel (using an
optional cable)
Outputs the life prediction signal
determining capacitor capacity
drop and cumulative running
hours. This allows the user to grasp
replacement period.
USB port equipped, BACnet equipped as standard.
Max. three types of built-in optional boards can be mounted all together.
Optional battery connection
Various communications options
Control board
The detachable control terminal
block is adopted. This allows the unit
to be replaced easily without
disconnecting cables.
Control terminal block
Drastically reduces harmonic noise. Conforming to
IEC/EN61000-3-2 and IEC/EN61000-3-12. Provided
as standard (to models up to 90kW), and can be
attached externally as an option (to models from
110kW to 710kW).
Capacitor board
Drastically reduces noise.
Provided to units of all
capacities. Conforming
to IEC61800-3.
EMC filter
Easy replacement just by
simply removing and
attaching the part. Life
prolongation is possible by
controlling ON and OFF.
Cooling fan
3C2, IEC60721-3-3 supported
Support/analysis software by loader, RTC backup by
battery (option)
DCR
Environmental immunity
Others
Standard equipment Optional equipment
• BACnet MS/TP
• Modbus RTU
• Metasys N2
• LonWorks
• Ethernet
• Profi bus
• DeviceNet
• CANopen
• CC-Link
User-friendly, easy to see dedicated keypad
9. 8
The system is configured by combining the motor
driven by the inverter (M0), motors that are
commercially driven (M1 to M8) and auxiliary motor
(MA). The motor driven by the inverter is always fixed
as motor M0. Motors commercially driven are added
one by one in control when the required discharge
flow rate cannot be achieved with the motor M0 only.
1. Inverter drive motor fixed method (FIXED)
The cascade control is the function that controls the
multiple pumps by one inverter. The pumps are
controlled with combination of inverter drive and
commercial drive. This can be applied in a large-scale
water treatment plant.
In cascade control, the signals of flow rate and
pressure sensors are controlled by the PID regulator
that is built in the inverter. Each pump is driven either
by the inverter or commercially according to the
switching signal from the inverter. The pumps are
controlled only by the inverter when the discharge
volume is small, and adding to the inverter drive, they
are controlled using commercial drive by adding them
one by one as the discharge volume gets larger in
order to ensure the required discharge volume in total.
There are two following methods in control: inverter
drive motor fixed method and inverter drive motor
fixed method.
Optimal Function for Usage in Water Treatment
Cascade control
Pressure
sensor
Contactor box
FRENIC-AQUA
Pump
Pump
Pump
Pump
Pump
Pump
Pump
Pump
Pump
Auxiliary
pump
Command
Control
unit for
pump
Pressure sensor
PID
HLRINV
R
S
T
U
V
W
M1_L
M2_L
M3_L
M4_L
M5_L
M6_L
M7_L
AUX_L
M8_L
M0
M1
M2
M3
M4
M5
M6
M7
M8
MA
Inverter drive motor fixed method (FIXED)
Max. 1 unit
(Driven by inverter)
8 units
(Commercially driven)
1 unit
(Auxiliary motor)
10. 9
The system for this method is configured by
combining the motors that can be switched between
inverter drive and commercial drive (M1 to M4) and
auxiliary motor that are commercially driven (MA). The
motors are driven by the inverter with variable speed
control at start. When the desired discharge flow rate
cannot be achieved with the first motor, operations
FLOATING-1 or FLOATING-2 can be selected.
2. Inverter drive motor floating method (FLOATING)
Inverter drive motor floating method (FLOATING)
Max. 4 units 1 unit (Auxiliary motor)
Control
unit for
pump
PID
HLRINVR
S
T
U
V
W
M1_I
M1_L
M2_I
M2_L
M3_I
M3_L
M4_I
M4_L
AUX_L
Pump
Pump
Pump
Pump
Auxiliary
pump
Pressure sensor
M1
M2
M3
M4
MA
The system can be configured without using a
controller by connecting the inverters via
communications. In this system, if a failure occurs to
the master inverter, the next inverter is driven as the
master inverter. Moreover, wiring can be saved with
use of communications services, which eliminates the
need of additional options by using the Modbus RTU
communications.
Mutual operation
The first motor: Inverter drive continued
Second and subsequent motors: Commercially driven
FLOATING-1
FLOATING-2
The first motor:
Switched as a commercially driven motor
Second and subsequent motors:
Operated by inverter drive
The inverter-driven motor is changed by rotation as the motor is added.
Command
PID control
PID
control
Accel/decel
control
Pressure sensor
Pump
Feedback
L1/R
L2/S
L3/T
U
V
W
Command PID
control
Accel/decel
control
Pressure sensor
Pump
Feedback
L1/R
L2/S
L3/T
U
V
W
Command PID
control
Accel/decel
control
Pressure sensor
Pump
Feedback
L1/R
L2/S
L3/T
U
V
W
M0
M0
M0
Command
11. +
-
10
Frequency can be output forcibly at a fixed rate in preference to PID
control. By setting the operation frequency, operation time, and
acceleration time at starting, optimal operation for starting the
pump can be achieved.
• Pressurizing operation can be applied for a certain period
of time at the time of start.
Function codes can be read/write, displayed or hidden
by setting the two passwords. This prevents erroneous
operation or overwriting of function codes. In
addition, if a wrong password was input exceeding the
specified number of times, the inverter is restricted
from operating as the user is regarded as improper.
Password
Pump dry condition can be detected from PID
deviation value by setting the output frequency,
output current, and flow rate sensor value. Water
leakage and pressure drop due to impeller damage
can be detected as well.
Dry pump detection
The customized logic interface function is provided to the inverter body. This enables forming of logic circuit and
arithmetic circuit to the digital and analog input and output signals, allowing simple relay sequence to be built
while processing the signals freely.
Customized logic
Boost function
X1 terminal 12 terminal
C1 terminal
U04
U04
U05
LE1
LE2
On-delay timer
Step 1
X2 terminal
Y1
output
terminal
Y3
output
terminal
Example
0.2
Pressure
[FDT]
Time
Operation frequency
Operation time
0
12. 11
The inverter can be stopped when the discharge rate becomes low due to increase of pump discharge pressure.
Facility having a bladder tank can make the stoppage period longer by applying pressure immediately before
stoppage, which realizes energy-saving operation.
Slow flowrate function (pressurized operation available before slow flowrate)
Frequency level for
slow flowrate function
Output current
Elapse time before stop
with slow flowrate
Pressurization time before stop
with slow flowrate
Pressurization frequency before stop with slow flowrate
The motor is rotated in reverse when it is determined
that any abnormality, such as being engaged or
trapped, is occurred. If sand or dust were caught in the
impeller with a submerged pump and overcurrent
protection function is activated, the motor is rotated in
reverse at restart so that the sand and dust are ejected
from the impeller. Then, the motor resumes rotation in
forward, allowing water to be supplied in a normal
manner.
Anti-jam function
If a valve is closed quickly after pump stoppage, there
is a risk of damaging the check valve (piping, pump,
valves, etc.) due to water hammer phenomenon. To
protect the check valve from this, the pump speed is
gradually slowed down when the check valve closes.
Deceleration time for check valve protection
When a pump such as a deep well pump is operated at low speed over a long period of time, the pump may be
damaged since the load current is large in the low-speed range. It is possible to provide acceleration/deceleration
time specific to the low-speed range in order to avoid prolonged operation.
Initial acceleration/deceleration time
Output frequency
Starting frequency
Startup frequency
PID output (MV)
Operation instruction
Signal during slow flowrate function
[PID-STP]
ON
ON
Timer
t
t
Low frequency domain
Output frequency
Output frequency
Output frequency
Minimum frequency
Lower limiter
Switching frequency
PID control: PID-CTL ON
Initial
acceleration time
Initial
deceleration ime
Deceleration time for
check valve protection
Check valve
protection frequency
Slow flowrate function
Slow flowrate function
Start
Other featured functions
• 4PID control
• Control of maximum starts per hour
• Abnormal pressure rise prevention
• End of curve detection
• Pick-up operation
• 4PID control
• Control of maximum starts per hour
• Abnormal pressure rise prevention
• End of curve detection
• Pick-up operation
13. 12
3-phase, 400V series (0.75 to 55kW)
3-phase, 400V series (75 to 710kW)
Type
Braking
Nominal applied motor (Rated output) [kW] *1
EMC filter (IEC/EN 61800-3:2004)
DC reactor (DCR)
Power factor(at rated load)
Efficiency (at rated load)
Applicable safety standards
Enclosure (IEC/EN 60529)
Cooling method
Weight/Mass [kg]
OutputratingsInputratings
*1) Fuji 4-pole standard motor.
*2) Rated capacity is calculated by assuming the output rated voltage as 440 V.
*3) Output voltage cannot exceed the power supply voltage.
*4) The auxiliary power input is used as an AC power input when combining the unit to DC power supply such as high power factor PWM converter
with power regenerative function. (Generally not to be used.)
*5) Voltage unbalance [%] = (Max. voltage [V] - Min. voltage [V])/Three-phase average voltage [V] x 67 (See IEC61800-3.)
If this value is 2 to 3%, use an optional AC reactor (ACR).
*6) The value is calculated on assumption that the inverter is connected with a power supply 400V, 50Hz and Rsce=120.
*7) Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)
SpecificationsItem
Standard Specifications
FRN AQ1 -4A : AQUA
FRN AQ1 -4E : AQUA
Rated capacity [kVA] *2
Rated voltage [V] *3
Rated current [A]
Overload capability
Rated frequency [Hz]
Main circuit power input : Phases, voltage, frequency
Auxiliary control power input : Phases, voltage, frequency
Auxiliary power input for main circuit :Phases, voltage, frequency *4
Voltage, frequency variations
Rated current [A] *6
Required power supply capacity [kVA]
Torque [%] *7
DC injection braking
Three-phase, 380 to 480 V (with AVR function)
110% - 1 min (Overload capability interval : IEC 61800-2 compliant)
50, 60Hz
Single-phase 380 to 480 V,50/60 Hz
Voltage: +10 to -15% (Interphase voltage unbalance : 2% or less) *5
, Frequency: +5 to -5%
Starting frequency:0.0 to 60.0Hz, Braking time:0.0 to 30.0s, Braking level:0 to 60%
EMC standards compliance : Category C2 (emission) / 2nd Env. (Immunity)
Built-in (IEC/EN 61000-3-2, IEC/EN 61000-3-12)
>0.98
>=0.90
UL508C, IEC/EN 61800-5-1:2007
IP21/IP55
Fan cooling
95%
20 10 to 15
96% 97%
Displacement P.F. (cosφ)
True P.F.
IP21
IP55
0.75
0.75
0.75
1.9
2.5
1.6
1.2
10
10
1.5
1.5
1.5
3.1
4.1
3.0
2.1
10
10
2.2
2.2
2.2
4.1
5.5
4.3
3.0
10
10
3.7
4.0
3.7/4.0
6.8
9.0
7.4
5.2
10
10
5.5
5.5
5.5
10
13.5
10.3
7.2
10
10
7.5
7.5
7.5
14
18.5
13.9
9.7
10
10
11
11
11
18
24.5
20.7
15
18
18
15
15
15
24
32
27.9
20
18
18
18.5
18.5
18.5
29
39
34.5
24
18
18
22
22
22
34
45
41.1
29
18
18
30
30
30
45
60
55.7
39
23
23
37
37
37
57
75
69.4
49
23
23
45
45
45
69
91
83.1
58
50
50
55
55
55
85
112
102
71
50
50
Three-phase, 380 - 440 V, 50 Hz
Three-phase, 380 - 480 V, 60 Hz
Single-phase 380 - 440 V, 50 Hz
Single-phase 380 - 480 V, 60 Hz
Type
Braking
Nominal applied motor (Rated output) [kW] *1
EMC filter (IEC/EN 61800-3:2004)
DC reactor (DCR)
Power factor(at rated load)
Efficiency (at rated load)
Applicable safety standards
Enclosure (IEC/EN 60529)
Cooling method
Weight/Mass [kg]
OutputratingsInputratings
SpecificationsItem
FRN AQ1 -4A : AQUA
FRN AQ1 -4E : AQUA
Rated capacity [kVA] *2
Rated voltage [V] *3
Rated current [A]
Overload capability
Rated frequency [Hz]
Main circuit power input : Phases, voltage, frequency
Auxiliary control power input : Phases, voltage, frequency
Auxiliary power input for main circuit :Phases, voltage, frequency *4
Voltage, frequency variations
Rated current [A] *6
Required power supply capacity [kVA]
Torque [%] *7
DC injection braking
Three-phase, 380 to 480 V (with AVR function)
110% - 1 min (Overload capability interval : IEC 61800-2 compliant)
50, 60Hz
Three-phase, 380 to 440 V, 50 Hz Three-phase, 380 to 480 V, 60 Hz
Single-phase 380 to 480 V,50/60 Hz
Single-phase 380 to 440 V, 50 Hz Single-phase 380 to 480 V, 60 Hz
Voltage: +10 to -15% (Interphase voltage unbalance : 2% or less) *5
, Frequency: +5 to -5%
10~15
Starting frequency:0.0 to 60.0Hz, Braking time:0.0 to 30.0s, Braking level:0 to 60%
>0.98
>=0.90
UL508C, IEC/EN 61800-5-1:2007
Fan cooling
97% 98%
Built-in (IEC/EN61000-3-2,
IEC/EN61000-3-12) Standard accessory (IEC/EN 61000-3-2, IEC/EN 61000-3-12)
C2/2nd. EMC standards compliance : Category C3 (emission) / 2nd Env. (Immunity)
-
-
Displacement P.F. (cosφ)
True P.F.
IP21
IP55
IP00
IP21/IP55 IP00
Three-phase, 380 to 480 V, 50/60 Hz
-
315
315
315
445
585
559
388
245
75
75
75
114
150
136
95
70
70
90
90
90
134
176
162
113
70
70
110
110
110
160
210
201
140
62
132
132
132
192
253
238
165
64
160
160
160
231
304
286
199
94
200
200
200
287
377
357
248
98
220
220
220
316
415
390
271
129
280
280
280
396
520
500
347
140
355
355
355
495
650
628
436
245
400
400
400
563
740
705
489
245
500
500
500
731
960
881
611
330
630
630
630
891
1170
1115
773
530
710
710
710
1044
1370
1256
871
530
14. 13
Common Specifications
RemarksItems Specifications
Output
Settingrange
Control
Maximum frequency
Output frequency
Accuracy (Stability)
Setting resolution
Control method
Base frequency
Starting frequency
Carrier frequency
• 25 to 120 Hz
• 25 to 120 Hz variable setting
• 0.1 to 60.0 Hz variable setting
• Analog setting : ±0.2% of max. frequency (at 25 ± 10 )
• Digital setting : ±0.01% of max. frequency (at -10 to +50 )
• Analog setting : 1/3000 of max. frequency (1/1500 with [V2] input)
• Digital setting : 0.01 Hz (99.99 Hz or less), 0.1Hz (100.0 to 120 Hz)
• Link setting : 1/20000 of max. frequency or 0.01 Hz (fixed)
• V/f control
• Dynamic torque vector control
• V/f control, the slip compensation is available.
Voltage/frequency
characteristic
• Base frequency and max. output frequency can be set to 160 to 500V in common.
• The AVR control ON/OFF can be selected.
• Non-linear V/f setting (3 points) : Free voltage (0 to 500 V) and frequency (0 to 120 Hz) can be set.
Torque boost
• Auto torque boost
• Manual torque boost : Desired torque boost (0.0 to 20.0%) can be set.
• Select application load with function code.(Constant torque load or variable torque load)
"+1 to +5 VDC"
can be adjusted
with bias and
analog input gain.
Starting torque
• 100% or higher/set frequency : 1.0 Hz
Base frequency 50 Hz, Slip compensation and auto torque boost operation
Acceleration/
deceleration time
Frequency limiter
(Upper limit and lower
limit frequencies)
Bias frequency
Analog input
• Setting range : 0.00 to 3600 s
• Switch : The four types of accel./decel. time can be set or selected individually. (switchable during operation)
• Acceleration/deceleration pattern : Linear accel./decel., S-shape accel./decel. (weak, strong),
curvilinear accel./decel. (accel./decel. max. capacity of constant output)
• Deceleration mode (coast-to-stop) : Coast-to-stop at the operation command OFF.
• Forcible stop decel. time : Deceleration stop by the forcible stop .
• Both upper and lower limit frequencies can be variably set in hertz.
• It is possible to choose the operation done from continuous operation at
lower limit frequency or operation stop when the set frequency drops below the lower limit.
• Bias of set reference frequency and PID command can be independently set. (setting range : 0 to ±100%)
• Gain : Setting in the range from 0 to 200%.
• Off-set: Setting in the range from -5.0 to +5.0%.
• Filter : Setting in the range from 0.00s to 5.00s.
Jump frequency
• Actuation points (3 points) and their common jump widths (0 to 30 Hz) can be set.
• Resonance points can be detected automatically and be set the jump frequency automatically.
Auto-restart after
momentary power failure
• Trip at power failure : The inverter trips immediately after power failure.
• Trip at power recovery : Coast-to-stop at power failure and trip at power recovery.
• Continuous operation : Operation is continued using the load inertia energy.
• Start at the frequency selected before momentary stop : Coast-to-stop at power failure
and start after power recovery at the frequency selected before momentary stop.
• Start at starting frequency : Coast-to-stop at power failure and start at the starting frequency after power recovery.
• Keypad : Can be set with and keys.
• External Volume : Can be Set with external potentiometer (1 to 5kΩ 1/2W).
• Analog input : 0 to ±10 VDC (±5 VDC)/0 to ±100% (Terminals [12] and [V2])
0 to +10 VDC (+5 VDC)/0 to +100% (Terminals [12] and [V2])
+4 to +20 mADC/0 to 100% (Terminal [C1])
0 to +20 mADC/0 to 100% (Terminal [C1])
• UP/DOWN operation : Frequency can be increased or decreased while the digital input signal is ON.
• Multi-frequency : Selectable from 16 steps (step 0 to 15).
• Link operation : Frequency can be set via RS-485 (Standard accessory).
• Switching frequency setting : Frequency setting can be switched (2 settings) by external signal (digital input).
Remote/local switching, link switching.
• Auxiliary frequency setting : Terminal [12],[C1] or [V2] input can be selected respectively as an additional input.
• Inverse operation : The setting "0 to +10 VDC/0 to 100%" can be switched to "+10 to 0 VDC/0 to 100%" by external command.
The setting "+4 to +20 mADC/0 to 100%" can be switched to "+20 to +4 mADC/0 to 100%" by external command.
The setting "0 to +20 mADC/0 to 100%" can be switched to "+20 to 0 mADC/0 to 100%" by external command.
• Programmed PATTERN operation : Maximum 7 stages can be set.
• 0.75 to 16 kHz variable setting (0.75 kW to 37 kW)
• 0.75 to 10 kHz variable setting (45 kW to 90 kW)
• 0.75 to 6 kHz variable setting (110 kW to 630 kW)
• 0.75 to 4 kHz variable setting (710 kW)
NOTE: Frequency drops automatically to protect the inverter depending on environmental temperature and output current.
(This auto drop function can be canceled.)
Start/stop operation
Frequency setting
Current limit
by hardware
• Limiting the current by hardware to prevent overcurrent trip due to sharp load change
or momentary power failure which cannot be controlled by software current limit. (This function can be cancelled.)
Operation by
commercial power supply
• With commercial power switching command, the inverter outputs 50Hz/60 Hz (SW50, SW60).
• The inverter has the commercial power supply switching sequence.
Slip compensation • Compensates for decrease in speed according to the load.
Torque limiter • Switchable between 1st or 2nd torque limit values.
Current control (software current limit) • Automatically reduces the frequency so that the output current becomes lower than the preset operation level.
• Keypad : Start and stop with , and keys.
• External signals (digital inputs) : Forward (Reverse) rotation, stop command (capable of 3-wire operation),
coast-to-stop command,external alarm, alarm reset, etc.
• Link operation : Operation through RS-485 or field bus (option) communications.
• Switching operation command : Remote/Local switching, link switching.
15. 14
Common Specifications
RemarksItems Specifications
ControlDisplay
Deceleration characteristic
(improving braking ability)
• The motor loss is increased during deceleration to reduce the regenerative energy in the inverter to avoid overvoltage trip.
Automatic energy saving operation • The output voltage is controlled to minimize the total sum of the motor loss and inverter loss at a constant speed.
Overload prevention control • If the ambient temperature or IGBT joint temperature increases due to overload, the inverter lowers the output frequency to avoid overload.
Voltage ShortageAvoidance Operation • The continuous operation is available reducing output frequency during low voltage.
InputPhaseLossProtectionAvoidanceOperation • Selectable from trip or continuous low power operation.
Off-line tuning • Rotary type and non-rotary type are available for tuning the motor constant.
Universal DI • The status of external digital signal connected with the universal digital input terminal is transferred to the host controller.
Universal DO • Digital command signal from the host controller is output to the universal digital output terminal.
Universal AO • The analog command signal from the host controller is output to the analog output terminal.
Rotation direction control • Preventing reverse rotation • Preventing forward rotation
Preventing condensation in motor
Customized logic interface
• When the inverter is stopped, current is automatically supplied to the motor to keep the motor warm and avoid condensation.
• Available in 14 steps with the functions of 2-input, 1-output, logical calculation, and timer function.
Fire mode • Continues operation without alarm by retry.
Pattern operation • Pattern operation is available by inverter itself.
Timer operation • Set 4-timers for one week.
Password function • Prevent improperly operation and/or data undisplayed available. (two level setting.)
Mutual operation • Connectable between inverters with RTU communications. (maximum 3 pcs.)
Light-alarm • WARN. LED is lit and light-alarm factor is displayed.
Trip mode • Displays the cause of trip.
LED display • LED for light-alarm or alarm occurrence.
Running or trip mode
• Trip history : Saves and displays the cause of the last ten trips (with a code).
• Detail data recorded : Saves and displays the detail data recorded on occurrence of the last four trips.
• Saves and displays the date, hour and minute with RTC.
Cumulative running hours
• Displays the inverter cumulative running hours, integrated power, cumulative motor running hours, and the number of operation start times.
• Outputs the warning when the maintenance time or the number of start times has exceeded the preset value.
• Displays the cumulative energy for unit of months, weeks, days and hours and running hours (with RTC).
Inverter life warning
• Life judgment of the main circuit capacitor, electrolytic capacitor on printed circuit board, and cooling fan.
• Life warning information can be output to an external device.
• Ambient temperature : IP00/IP21 40 , IP55 30 , Load rate : inverter rated current 100%
Run/stop
Speed monitor (set frequency, output frequency, motor speed, load shaft speed, line speed, and speed indication with percent), Output current [A],
output voltage [V], calculated torque [%], input power [kW], PID reference value, PID feedback value, PID output, load [%], motor output [kW],
analog input monitor, integral power consumption [kWh], integral power consumption [MWh], effective current value for each phase [A]
External PID control
• PID processor for process control / On / Off controller (3 channels) • Normal operation / inverse operation
• PID command: Keypad, analog input (terminals [12], [C1] and [V2]), RS-485 • PID feedback value (terminals [12], [C1] and [V2])
• Alarm output (absolute value alarm, deviation alarm) • PID feedback error detection • Sensor input amount scaling
• Sensor input amount conversion / calculation • PID output limiter • Integration reset / hold • Anti-reset wind-up function
Pump control
• Cascade control (FIXED:1+8 pcs,FLOATING:4 pcs (with option)) • Periodic motor switching
• Promptly connection/disconnection for auxiliary motor • Control of maximum starts per hour • Dry pump detection
• End of curve detection • Filter clogging prevention • Anti jam • Check valve protection • Boost function
Cooling fan
ON/OFF control
• Detects inverter internal temperature of the inverter and stops the cooling fan when the temperature is low.
• The fan control signal can be output to an external device.
Automatic deceleration
• If the DC link voltage or calculated torque exceeds the automatic deceleration level during deceleration,
the inverter automatically prolongs the deceleration time to avoid overvoltage trip.
(It is possible to select forcible deceleration actuated with more than three times longer deceleration.)
• If the calculated torque exceeds automatic deceleration level during constant speed operation,
the inverter avoids overvoltage trip by increasing the frequency.
• Automatic deceleration level can be set.
Auto search for idling
motor speed
• Estimates the speed of the motor running under no load and starts the motor without stopping it.
(Motor electric constant needs tuning : Offline tuning)
PID control
• PID adjuster for process contro • Switchable between forward and reverse operations
• Slow flowrate function (pressurized operation available before slow flowrate) • Automatic update for slow flowrate frequency
• PID command : Keypad panel, analog input (from terminals [12],[C1],[V2]), RS-485 communications
• PID feedback value : Analog input (from terminals [12],[C1],[V2]) • Alarm output (absolute value alarm, deviation alarm)
• PV level detection • Scaling for PV value • PV value conversion/calculation of analog input
• PID output limiter • Integration reset/hold • Antireset windup • PID auto tuning
Real time clock (RTC)
• Date, hour and alarm information with date and hour can be displayed, and timer operation can be used with RTC.
• Daylight saving time auxiliary function.
Time can be maintained
with battery (option).
Protectivefunction
Guidance function • Needed information can be displayed by pushing "HELP" key.
Battery level display • Battery level can be displayed when the battery (option) is connected.
LCD back-light • Set lighting time for LCD back-light during key operation only or unlit.
OC1,OC2,OC3
OU1,OU2,OU3
LU
Lin
Overcurrent protection • The inverter is stopped for protection against overcurrent.
Short-circuit protection • The inverter is stopped for protection against overcurrent caused by a short circuit in the output circuit.
Ground fault protection • The inverter is stopped for protection against overcurrent caused by a grounding fault in the output circuit. (37 kW or less)
Input phase loss
protection
• The input phase loss is detected to protect or shut off the inverter.
• When the load to be connected is small, a phase loss would not be detected.
Undervoltage protection
• The voltage drop (400 VDC) in the DC link circuit is detected to stop the inverter.
However, the alarm will not be issued when the re-starting after instantaneous stop is selected.
Overvoltage protection
• An excessive voltage (800 VDC) in the DC link circuit is detected and the inverter is stopped.
If an excessive voltage is applied unintended, the protection can not be guaranteed.
Multi language
• Corresponded to Japanese, English, German, French, Spanish, Italian, Chinese, Russian, Greek, Turkish, Polish, Czech, Swedish,
Portuguese, Dutch, Malay, Vietnamese, Thai and Indonesian. (Sequential correspond to User Customized Language.)
OPLOutput phase loss detection • Detects breaks in inverter output wiring at the start of running and during running and stop the inverter output.
16. OH3
15
RemarksItems Specifications
ProtectivefunctionEnvironment
Motorprotection
Er1
Er2
Er3
Er4
Er5
Er6
Er7
Er8
ErF
ErH
Err
CoF
ECL
Pdr
roC
PoL
rLo
FoL
ECF
PV1,PV2,PVA,PVb,PVC
ErP
OH1
OLU
OH2
OL1
OH4
Overload protection • Stop the inverter output detecting a switching element temperature calculated with cooling fin temperature and the output current.
External alarm input • With the digital input signal (THR), the inverter is stopped with an alarm.
Memory error • Data is checked upon power-on and data writing to detect any fault in the memory and stop the inverter if any.
CPU error • Stop the inverter detecting a CPU error or LSI error caused by noise.
Option communications error • When each option is used, a fault of communication with the inverter main body is detected to stop the inverter.
Option error • When each option is used, the option detects a fault to stop the inverter.
Tuning error • Stop the inverter output when tuning failure, interruption or any fault as a result of tuning is detected during tuning for motor constant.
Data save error upon undervoltage • When the undervoltage protection occurred, an alarm is displayed if the data is not properly saved.
Hardware error • Stop the inverter detecting a LSI error on the power printed circuit board caused by noise.
Simulation error • Simulated alarm is output by the keypad panel operation.
Current input wire break detection • Stop the inverter detecting a analog wire break detection (enable / disable selectable).
PID feedback error detection • Stop the inverter output detecting a PID feedback line break. (Selectable valid/invalid.)
Customized logic error detection • Alarm is output detecting a customized logic setting error.
Drought protection • Display the error detecting the drought during PID control.
Protect high frequency operation • Display the error detecting the frequent slow flowrate during PID control.
End of curve detection • Display the error detecting the big amount of water during PID control.
Anti jam protection • Display the error detecting the starting failure due to overcurrent.
Filter clogging prevention • Display the error detecting the overload during PID control.
Enable circuit failure detection • Diagnos the enable circuit condition and stop the inverter output detecting the circuit failure.
Surge protection • The inverter is protected against surge voltage intruding between the main circuit power line and ground.
Ambient humidity • 5 to 95 %RH (without condensation)
Altitude • 1,000m or lower
Storage temperature • -25 to +70
Storage humidity • 5 to 95 %RH (without condensation)
Vibration
90kW or less 110 to 710kW
3mm : 2 to less than 9 Hz 3mm : 2 to less than 9 Hz 1m/s2
: 55 to less than 200Hz
10m/s2
: 9 to less than 200Hz 2m/s2
: 9 to less than 55Hz
Installation location • Free from corrosive gases, flammable gases, dusts, oil mist, direct sunlight. (Pollution degree 2 (IEC60664-1)). Indoor use only.
Ambient temperature
• -10 to +50 (+50 to +60 : correspond with deleting)
(-10 to +40 : installed side-by-side without clearance (37 kW or less))
IP21
IP55
IP00
Command loss detected
• A loss (breaking, etc.) of the frequency command is detected to output an alarm and the operation is continued at the preset frequency
(set at a ratio to the frequency before detection).
Retry function
• When the motor is tripped and stopped, this function automatically resets the tripping state and restarts operation. (Retry times, waiting
time for reset, corresponding trip for retry and retry available time can be set.) It can be confirmed by communication the times of the restarting.
Stall prevention
• Operates when the inverter output goes beyond the instantaneous overcurrent limiting level, and avoids tripping, during acceleration
and constant speed operation.
Light-alarm (warning)
• Light- alarm is displayed when registered alarm or warning as light-alarm is occurred. (continuous running)
Covered alarm :
External alarm (OH2), Inverter overheat (OH3), Motor overheat (OH4), Motor overload (OL1),
Keypad panel communication error (Er2), Optional communication error (Er4), Option error (Er5),
RS-485 communication error (port 1)(Er8), RS-485 communication error (port 2)(ErP), DC fan lock detected,
Overload early warning (for motor), Heatsink overheat early warning,
Life early warning (DC link bus capacitor, electrolytic capacitor on printed circuit board, cooling fan),
Reference command loss detected, PID warning output, Low torque detected, Thermistor detection (PTC),
Machine life (cumulative motor run time error), Machine life (number of startups error), Current Input Wire Break Detection,
PID feedback error detection, Low battery warning, Date&time information lost, Mutual operation slave alarm
Alarm relay output
(for any fault)
• The inverter outputs a relay contact signal when the inverter issues an alarm and stops the inverter output.
• The alarm stop state is reset by pressing the key or by the digital input signal (RST).
RS-485 communications
error (port2)
• Stop the inverter output detecting the communication error between the inverter main unit and a mate when the RS-485 connection
port of the [DX+], [DX-] are used to configure the network.
RS-485 communications
error (port1)
• Stop the inverter output detecting the communication error between the inverter main unit and a mate when the RS-485 connection
port of the keypad panel is used to configure the network.
Operation error
• key priority : Pressing the key on the keypad will forcibly decelerate, stop the motor and display "Er6" even if the running
command through signal input or communication is selected.
• Start check : If the running command is being input when switching the running command method from power-on, alarm reset or
the linked operation, the operation starts suddenly. This function prohibits running and displays "Er6".
Keypad panel
communications error
• The keypad panel detects a communication fault between the keypad panel and the inverter main body during the run command
from the keypad panel available and to stop the inverter.
PTC thermistor
• PTC thermistor input stops the inverter to protect the motor.
Connect a PTC thermistor between terminal [C1] and [11] and set the switch on control print board and the function code.
Overload early warning • Warning signal (OL) is output at the predetermined level befor with electronic thermal function.
Electronic thermal
• The inverter is stopped with an electronic thermal function set to protect the motor. Protects the general-purpose motor and inverter
motor over all frequency range. (The level and thermal time constant (0.5 to 75.0 min) can be set.)
Overheat protection • Stop the inverter output detecting inner temperature of the inverter unit for a cooling fan fault or overload.
• Stop the inverter output detecting the cooling fan failure. • Stop the inverter output detecting the charging circuit fault.
• Stop the inverter output detecting excess cooling fin temperature in case of a cooling fan fault or overload.
• -10 to +40 (+40 to +50 : correspond with deleting)
(-10 to +30 : installed side-by-side without clearance (37 kW or less))
• -10 to +50
*1 Detection of all circuit failures is not guaranteed (EN ISO 13849-1 Cat.3 compliant).
*2 Alarm (ECF) is occurred when one of the inputs of EN1 or EN2 are OFF (If it exceeds 50 ms, it will be as disagreement.). Power supply reboot only to reset this alarm.
*3 Apply by wire to turn off enable command and stop the inverter output with feedback signal assigned DECF signal of inverter
Momentary power failure protection • If restart upon momentary power failure is selected, the inverter restarts upon recovery of the voltage within the set time.
17. 16
Model variation
How to read the model number
FRN 0.75 AQ1 M - 4 A
Series name:FRN
Standard applicable
motor capacity
Applied for:AQ:AQUA
Input power supply:
4:400V
Protection structure:
M:IP21
L:IP55
S:IP00
Destination:
A:Asia
E:Europe
C:China
(Protective structure) : M : IP21, L : IP55(0.75 to 90kW), S : IP00(110 to 710kW)
(Destination) : A : Asia, E : Europe, C : China
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
220
280
315
355
400
500
630
710
3-phase
400V
Europe
/Asia/China
(E/A/C)
Rated
voltage
Destination Type
Nominal applied
motor
B
D
F
H
J
150
203
203
265
300
530
680
880
1000
465
585
645
736
885
740
1000
1000
1400
1400
1550
262
262
262
284
367.9
315
360
360
440
440
500
162
162
162
184.5
240.8
135
180
180
260
260
313.2
115
158
158
180
215
430
290
260
300
17.5
22.5
22.5
42.5
50
50
50
49.5
451
571
631
716
855
710
970
970
1370
1370
1520
7
7
7
12
15.5
15.5
15.5
15.5
W W1 W2H H1 H2
-
8
14.5
14.5
14.5
14.5
H3
2x 8
2x 10
2x 15
2x 15
3x 15
4x 15
M
8
10
15
15
15
15
ND D1 D2
Outside dimensions (mm) Mounting dimensions (mm)
Dwg.no. Dwg.no.
100
100
100
99.5
127.1
180
180
180
186.8
A
C
E
G
I
FRN0.75AQ1 -4#
FRN1.5AQ1 -4#
FRN2.2AQ1 -4#
FRN3.7AQ1 -4#
FRN5.5AQ1 -4#
FRN7.5AQ1 -4#
FRN11AQ1 -4#
FRN15AQ1 -4#
FRN18.5AQ1 -4#
FRN22AQ1 -4#
FRN30AQ1 -4#
FRN37AQ1 -4#
FRN45AQ1 -4#
FRN55AQ1 -4#
FRN75AQ1 -4#
FRN90AQ1 -4#
FRN110AQ1 -4#
FRN132AQ1 -4#
FRN160AQ1 -4#
FRN200AQ1 -4#
FRN220AQ1 -4#
FRN280AQ1 -4#
FRN315AQ1 -4#
FRN355AQ1 -4#
FRN400AQ1 -4#
FRN500AQ1 -4#
FRN630AQ1 -4#
FRN710AQ1 -4#
20. M
(7)
19
Outline drawing
W2 W2
N
W1 W1 W1
H3H1
D
D1 D2
H
W
H2
Body
I J
80 17.5 68.5
2×M3
5.8
8.2
7111.6
111.6
(13.7)
128
(80)
58
Panel cut part
8.2
15.1(14.6)
23
(128)
2.5
(5.8) 68.5
15.2(53.8)
11.7(17)
11.4
8.1
Keypad
2× 4
21. 20
Wiring Diagram
Basic configuration diagram
(Factory shipped condition: with SINK mode input and enable input function)
M
Alarm relay output
(for any fault)
AX terminal
function
During operation
Frequency (speed) agreement
Frequency (speed) detection
Motor overload prediction
Common terminal
(Shared between sink and source)
Data send/receive
RS-485 communications
port 2 (terminal block)
RS-485 communications port 1
(RJ-45 connector for
keypad connection)
Analog
frequency meter
Analog
frequency meter
0V+24VDC
0V+10VDC
Setting voltage input
0~±10VDC
Setting voltage input
(0~+10VDC)
(0~±10VDC)
0~10VDC
3~
Setting current input
4~20mADC
(0~20mADC)
4~20mADC
(0~20mADC)
0~10VDC
4~20mADC
(0~20mADC)
Control power AUX input *3
Power supply
400V series
380V~480V
50/60Hz
Ground terminal *4
Main circuit part
Ground terminal
Variable resistor
power supply
Magnetic contactor
(MC) *2
L1/R
L2/S
L3/T
13
12
111
3
2
R0
T0
G G
U
V
W
FWD operation/stop command
Enable input 1
Enable input 2
REV operation/stop command
Multi-step frequency selection (0~1steps)
Multi-step frequency selection (0~3steps)
Self-hold selection
Coast-to-stop command
Alarm reset
Local (keypad) instruction selection
Frequency setting 2/frequency setting 1
Digital input common
Digital input common
REV
CM
CM
X1
X2
X3
X4
X5
X6
X7
FWD
EN1
PTC
FM1
CMY
Y2
Y1
30C
30C
30C
Y5C
Y5A
30
Y3
Y4
FM2
11
SD
V2
C1
C1
SW5
EN2
PLC
*8
*7
SW1
SOURCE
SINK
*7
SW4
*7
SW6
*7
SW3
*7
*6
*5
SW2
*7
MCCB
or ELCB *1
*6
(+)
(-)
(+)
(-)
DX+
DX-
USB connector
Motor
P(-) P(+) N(-)
Analog input
Digitalinput
Control circuit part
Contact point output
Transistor
output
*6
22. 21
Basic configuration diagram
(Factory shipped condition: with SOURCE mode input and enable input function)
M
Alarm relay output
(for any fault)
AX terminal
function
During operation
Frequency (speed) agreement
Frequency (speed) detection
Motor overload prediction
Common terminal
(Shared between sink and source)
Data send/receive
RS-485 communications
port 2 (terminal block)
RS-485 communications port 1
(RJ-45 connector for
keypad connection)
Analog
frequency meter
Analog
frequency meter
0V+24VDC
0V+10VDC
Setting voltage input
0~±10VDC
Setting voltage input
(0~+10VDC)
(0~±10VDC)
0~10VDC
3~
Setting current input
4~20mADC
(0~20mADC)
4~20mADC
(0~20mADC)
0~10VDC
4~20mADC
(0~20mADC)
Control power AUX input *3
Power supply
400V series
380V~480V
50/60Hz
Ground terminal *4Ground terminal
Variable resistor
power supply
MCCB
or ELCB *1
Magnetic contactor
(MC) *2
L1/R
L2/S
L3/T
13
12
111
3
2
R0
T0
G G
U
V
W
FWD operation/stop command
Enable input 1
Enable input 2
REV operation/stop command
Multi-step frequency selection (0~1steps)
Multi-step frequency selection (0~3steps)
Self-hold selection
Coast-to-stop command
Alarm reset
Local (keypad) instruction selection
Frequency setting 2/frequency setting 1
REV
CM
CM
X1
X2
X3
X4
X5
X6
X7
FWD
EN1
PTC
FM1
CMY
Y2
Y1
30C
30C
30C
Y5C
Y5A
30
Y3
Y4
FM2
11
SD
V2
C1
C1
SW5
EN2
PLC
*8
*7
SW1
SOURCE
SINK
*7
SW4
*7
SW6
*7
SW3
*7
*6
*5
SW2
*7
*6
(+)
(-)
(+)
(-)
DX+
DX-
USB connector
Motor
P(-) P(+) N(-)
Digitalinput
Transistor
output
*6
Main circuit part
Control circuit part
Contact point output
Analog input
23. 22
Relay output interface card (OPC-RY)
Options
This is an optional card that converts the transistor output at
terminals Y1 to Y4 on the inverter body to relay output (1c). Each
card has two relay outputs, and four relay outputs are available
by installing two cards.
Note: When the card is mounted, the terminals Y1 to Y4 on the inverter body
Relay output:
Signal type:
Contact point capacity:
2 circuits built-in
1c
AC250V, 0.3A cos =0.
DC48V, 0.5A (Resistance load)
No. of connection nodes:
MAC ID:
Insulation:
Communications rate:
Network consumed power:
max. 64 units (including the master unit)
0~63
500V DC (photocoupler insulation)
500kbps/250kbps/125kbps
max. 80mA, 24V DC
Relay output interface card (OPC-RY2)
This optional card allows relay outputs (1a) to be added. When
used in cascaded control, this card can control the seven motors.
* By using the two relay outputs on the inverter body, max. 8 units and one unit
(auxiliary pump) can be controlled.
Relay output:
Signal type:
Contact point capacity:
7 circuits built-in
1a
AC250V, 0.3A cos =0.
DC48V, 0.5A (Resistance load)
No. of connection units:
Communications method:
Communications rate:
42 units
CC-Link Ver1.10 and Ver2.0
156kbps~
Analog input interface card (OPC-AIO)
This card allows analog input and output to be used.
Analog input:
Analog output:
1 analog voltage input point (0~±10V)
1 analog current input point (4~20mA)
1 analog voltage output point (0~±10V)
1 analog current output point (4~20mA)
Analog current output interface card (OPC-AO)
This card allows two analog current output (4 to 20mA) points to be used.
The card cannot be used together with OPC-G1-AIO.
CC-Link communications card (OPC-CCL)
By connecting this card with the CC-Link master unit, the
communications rate up to 10Mbps can be supported and the
transmission distance is covered up to 1200 m in total.
DeviceNet communications card (OPC-DEV)
This card enables operation instruction and frequency command
to be set from the DeviceNet master, allowing operation
conditions to be monitored and all the function codes to be
changed and checked.
Coming soon
Coming soon
24. 23
Optional type
CB-5S
CB-3S
CB-1S
Length (m)
5
3
1
Coming soon
PROFIBUS DP communications card (OPC-PDP2)
This card enables operation instruction and frequency command
to be set from the PROFIBUS DP master, allowing operation
conditions to be monitored and all the function codes to be
changed and checked.
Communications rate:
Transmission distance:
Connection connector:
9.6kbps~12Mbps
~1,200m
2×6-pole terminal block
CANopen communications card (OPC-COP)
This card enables operation instruction and frequency command
to be set from the CANopen master (such as PC and PLC),
allowing all the function codes to be set and checked.
No. of connection nodes:
Communications rate:
Transmission distance:
127 units
20k, 50k, 125k, 250k, 500k,
800k, 1Mbps
~2,500m
Extension cable for remote operation (CB- S)
This cable is used in connection between the inverter body and
the keypad.
LonWorks communications card (OPC-LNW)
Coming soon
Coming soon
This card allows peripheral equipment (including a master unit) that is connected via LonWorks to be connected with
the inverter, enabling operation instruction and frequency command to be set from the master unit.
Battery
Used for the real time clock activated while the inverter power is off. The real time clock can be operated even when
no power is supplied inverter at electric power interruption.
Ethernet communications card Coming soon
Pt100 temperature sensor input card (OPC-PT) Coming soon
This is an interface card for connecting FRENIC-AQUA with peripherals (such as a master) via Ethernet.
This card can connect FRENIC-AQUA with a mountable two-channel resistance temperature detector (hereinafter-called
RTD) to convert temperature values into digital values.
The following five types of mountable RTU are supported: JPt100, Pt100, Ni100, Pt1000, and Ni1000.
Coming soon
25. Gate City Ohsaki, East Tower, 11-2,
Osaki 1-chome, Shinagawa-ku,
Tokyo 141-0032, Japan
Phone: +81-3-5435-7057 Fax: +81-3-5435-7420
URL: http://www.fujielectric.com/
NOTES
When running general-purpose motors
• Driving a 400V general-purpose motor
When driving a 400V general-purpose motor with
an inverter using extremely long cables, damage to
the insulation of the motor may occur. Use an output
circuit filter (OFL) if necessary after checking with
the motor manufacturer. Fuji's motors do not require
the use of output circuit filters because of their
reinforced insulation.
• Torque characteristics and temperature rise
When the inverter is used to run a general-purpose
motor, the temperature of the motor becomes
higher than when it is operated using a commercial
power supply. In the low-speed range, the cooling
effect will be weakened, so decrease the output
torque of the motor. If constant torque is required in
the low-speed range, use a Fuji inverter motor or a
motor equipped with an externally powered
ventilating fan.
• Vibration
When the motor is mounted to a machine,
resonance may be caused by the natural
frequencies, including that of the machine.
Operation of a 2-pole motor at 60Hz or more may
cause abnormal vibration.
* Study use of tier coupling or dampening rubber.
* It is also recommended to use the inverter jump
frequency control to avoid resonance points.
• Noise
When an inverter is used with a general-purpose
motor, the motor noise level is higher than that with
a commercial power supply. To reduce noise, raise
carrier frequency of the inverter. High-speed
operation at 60Hz or more can also result in more
noise.
When running special motors
• Explosion-proof motors
When driving an explosion-proof motor with an
inverter, use a combination of a motor and an
inverter that has been approved in advance.
• Brake motors
For motors equipped with parallel-connected
brakes, their braking power must be supplied from
the primary circuit (commercial power supply). If the
brake power is connected to the inverter power
output circuit (secondary circuit) by mistake,
problems may occur.
Do not use inverters for driving motors equipped
with series-connected brakes.
• Geared motors
If the power transmission mechanism uses an oil-
lubricated gearbox or speed changer/reducer, then
continuous motor operation at low speed may
cause poor lubrication. Avoid such operation.
• Single-phase motors
Single-phase motors are not suitable for inverter-
driven variable speed operation. Use three-phase
motors.
Environmental conditions
• Installation location
Use the inverter in a location with an ambient
temperature range of -10 to 50 C.
The inverter and braking resistor surfaces become
hot under certain operating conditions. Install the
inverter on nonflammable material such as metal.
Ensure that the installation location meets the
environmental conditions specified in "Environment"
in inverter specifications.
Combination with peripheral devices
• Installing a molded case circuit
breaker (MCCB)
Install a recommended molded case circuit breaker
(MCCB) or an earth leakage circuit breaker (ELCB)
in the primary circuit of each inverter to protect the
wiring. Ensure that the circuit breaker capacity is
equivalent to or lower than the recommended
capacity.
• Installing a magnetic contactor (MC)
in the output (secondary) circuit
If a magnetic contactor (MC) is mounted in the
inverter's secondary circuit for switching the motor
to commercial power or for any other purpose,
ensure that both the inverter and the motor are fully
stopped before you turn the MC on or off. Remove
the surge killer integrated with the MC.
• Installing a magnetic contactor (MC)
in the input (primary) circuit
Do not turn the magnetic contactor (MC) in the
primary circuit on or off more than once an hour as
an inverter fault may result. If frequent starts or
stops are required during motor operation, use
FWD/REV signals.
• Protecting the motor
The electronic thermal facility of the inverter can
protect the general-purpose motor. The operation
level and the motor type (general-purpose motor,
inverter motor) should be set. For high-speed
motors or water-cooled motors, set a small value for
the thermal time constant to protect the motor.
If you connect the motor thermal relay to the motor
with a long cable, a high-frequency current may flow
into the wiring stray capacitance. This may cause
the relay to trip at a current lower than the set value
for the thermal relay. If this happens, lower the
carrier frequency or use the output circuit filter
(OFL).
• Discontinuance of power-factor correcting capacitor
Do not mount power factor correcting capacitors in
the inverter (primary) circuit. (Use the DC
REACTOR to improve the inverter power factor.) Do
not use power factor correcting capacitors in the
inverter output circuit (secondary). An overcurrent
trip will occur, disabling motor operation.
• Discontinuance of surge killer
Do not mount surge killers in the inverter output
(secondary) circuit.
• Reducing noise
Use of a filter and shielded wires are typical
measures against noise to ensure that EMC
Directives are met.
• Measures against surge currents
If an overvoltage trip occurs while the inverter is
stopped or operated under a light load, it is
assumed that the surge current is generated by
open/close of the phase-advancing capacitor in the
power system.
We recommend connecting a DC REACTOR to the
inverter.
• Megger test
When checking the insulation resistance of the
inverter, use a 500V megger and follow the
instructions contained in the Instruction Manual.
Wiring
• Wiring distance of control circuit
When performing remote operation, use the twisted
shield wire and limit the distance between the
inverter and the control box to 20m.
• Wiring length between inverter and motor
If long wiring is used between the inverter and the motor, the
inverter will overheat or trip as a result of overcurrent (high-
frequency current flowing into the stray capacitance) in the
wires connected to the phases. Ensure that the wiring is
shorter than 50m. If this length must be exceeded, lower the
carrier frequency or mount an output circuit filter (OFL).
When wiring is longer than 50m, and sensorless vector
control or vector control with speed sensor is selected,
execute off-line tuning.
• Wiring size
Select cables with a sufficient capacity by referring
to the current value or recommended wire size.
• Wiring type
Do not use multicore cables that are normally used
for connecting several inverters and motors.
• Grounding
Securely ground the inverter using the grounding
terminal.
Selecting inverter capacity
• Driving general-purpose motor
Select an inverter according to the applicable motor
ratings listed in the standard specifications table for
the inverter. When high starting torque is required or
quick acceleration or deceleration is required, select
an inverter with a capacity one size greater than the
standard.
• Driving special motors
Select an inverter that meets the following condition:
Inverter rated current > Motor rated current.
Transportation and storage
When transporting or storing inverters, follow the
procedures and select locations that meet the
environmental conditions that agree with the
inverter specifications.
Printed in Japan 2012-08(H12/L11)CM 30 FOLS