SlideShare a Scribd company logo
Do-It-Yourself
DataCenter
CablingSystem
%
Plug&
Play
Save50ormore
Step1:
Step2:
Step3:
4 Cablesys®
Plug&Play
Traditional
TraditionalCablingvs.Plug&PlayCabling
Traditional
Plug&Play
WhyDo-It-Yourself?
ResearchshowsCablesys’Plug&Playcablingsystemoutperformstraditionalcablingsolutions.
Cost Time50%
Less
laborandmaterialcost
100%
Privacy
noneedtohireoffsitepersonnel
No
Training
orcertifyingstaff
90%
Less
installationtime
Zero
Testing
allfactorytested
Modular
Design
forflexibleupgrades
5cablesys.com 800.555.7176 cs@cablesys.com
200
Bin Rangrequencmulative %
0.02 35 18%
0.04 36 36%
0.06 40 56%
0.08 30 71%
0.1 25 83%
0.12 24 95%
0.14 3 97%
0.16 4 99%
0.18 2 100%
0.2 1 100%
0.22 0 100%
0.24 0 100%
0.26 0 100%
0.28 0 100%
0.3 0 100%
35
36
40
30
25
24
3
4
2
1
0 0 0 0 0
18%
36%
56%
71%
83%
95% 97%
99% 100% 100% 100% 100% 100% 100% 100%
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.28 0.3
Performance
Testedupto5.7dBHeadroom
NEXT@Remote
120
100
80
60
40
20
0 50 100 150 200 250
12-36 12-45 12-78 36-45 36-78 45-78
Limit
Testedupto<=0.1dBInsertionLoss
ILHistogram
• OM3MultimodefibertestedperTIA®
specification
• 83%tested<=0.1dB,99%tested<=0.16dB
• ExceedsANSI/TIA568-C.3industrystandard
• Beatstheindustry’saverageof0.75dB
• ComplieswithIEEE802.3andIEC-60793-2-10standards
45
40
35
30
25
20
15
10
5
0
Frequency
• CAT6UTPtestedperTIAPermanentLinkspecification
• ExceedsANSI/TIA568-C.2industrystandard
• UL®
listedandETL®
verified
dB
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
ILBinRange
Fibercount
12page4page
Copper Fiber
6 Cablesys®
Copper Plug & Play
CopperPlug&Play
CablingSystem
Features
Pre-terminated
• CAT 6A, CAT 6 and CAT 5e
• To T-568-A or B wiring
Pre-bundled
• With durable PEP retardant yarn
• Six (6) cables per bundle
Pre-labeled
• On cables, bundles and cartons
• To customers’ requirement
Pre-tested
• To ANSI/TIA 568-C.2 industry standard
• 15 year performance warranty
Pre-kitted
• Sorting and packing products
• To customers’ requirement
7cablesys.com 800.555.7176 cs@cablesys.com
IdealPlug&Playlocations:
• Enterprise data centers
• Colocation facilities
• Server farms
• Cloud storage networks
• Telecommunication rooms
Plug & Play CablingTraditional Cabling
BezeltoBezel
For connectivity between patch panels.
Model#PCA
BezeltoModularPlugs
For connectivity between patch panel and network switch.
Model#PCB
1.ChooseConnectivity
BezeltoBezel PCA
BezeltoModularPlugs PCB
BezeltoMobileBox PCC
BezeltoOutletBox PCC
2.ChooseCableRating
Riser-ratedCMR
Plenum-ratedCMP
Consider fire rating of material and airflow. Most data center
environments can use riser-rated cable (CMR). Use CMR in vertical
settings, such as cable running between floors through cable risers.
Use plenum-rated cable (CMP) in raised flooring systems, drop
ceilings and air handling ducts. Always consult with city or building
authorities for the latest code before deciding the type of cable.
8 Cablesys®
Copper Plug & Play
Model #
BezeltoMobileBox
For connectivity between patch panel and mobile outlets.
Model#PCC
BezeltoOutletBox
For connectivity between patch panel and mobile outlets.
Model#PCC
4.ChooseLength
Standard(25, 50, 75 and 100 feet)
Custom(10 to 295 feet)
Consideraccessibilitytoactiveequipmentandthelayoutoftheroom
when measuring, then round up to the nearest foot. We pre-build
and stock cable assemblies in standard lengths to help reduce our
lead time and ship orders faster. We also custom build up to 295 feet
per TIA standard.
3.ChooseBandwidth
10GCAT6AShielded(FTP)
10GCAT6AUnshielded(UTP)
1GCAT6eUnshielded(UTP)
VoIPCAT5eUnshielded(UTP)
Consider what active equipment or devices will be supported
throughout the entire network. Use Foiled Twisted Pair (FTP) in
environments with high Electromagnetic Interference (EMI) or Radio
Frequency Interference (RFI). Use Unshielded Twisted Pair (UTP) in
environments with low interference.
9cablesys.com 800.555.7176 cs@cablesys.com
10 Cablesys®
Copper Plug & Play
Installation
Step1.
Install bracket panel. The panel fits
19 inch rack mount widths.
Step2.
Open package.
Step3.
Snap in bezels. Done!
11cablesys.com 800.555.7176 cs@cablesys.com
SupportRearCable
Useafive(5)inchbrackettosupport
cable on the rear of the patch panel.
Cable
Management
Brackets
• Three (3) and five (5) inch depths
• Supports front and rear cable
• Fits 19 inch rack mount widths
12 Cablesys®
Copper Plug & Play
Bundle6
TM
PatchCords
Model#BC6
We pre-bundled and pre-labeled six
(6) copper patch cords to save you
time and make patching easier.
1.ChooseBandwidth
10GCAT6AShielded(FTP)
1GCAT6eUnshielded(UTP)
VoIPCAT5eUnshielded(UTP)*
2.ChooseLength
Standard(7, 10, and 15 feet)
Custom(5 to 295 feet)
*Available in custom length only
Pre-bundled
To route cables faster. Wrap is removable.
13cablesys.com 800.555.7176 cs@cablesys.com
All-in-OnePackage
To save time from opening multiple packages.
Pre-labeled
To easily identify cables.
FiberPlug&Play
CablingSystem
Features
Pre-terminated
• LC fiber connectors
• 15 year performance warranty
Pre-bundled
• With durable PEP retardant yarn
• Six (6) cables per bundle
Pre-labeled
• On cables, bundles and cartons
• To customers’ requirement
Pre-tested
• To ANSI/TIA 568-C.3 industry standard
• 0.2dB or less Insertion Loss
Pre-kitted
• Sorting and packing products
• To customers’ requirement
14 Cablesys®
Fiber Plug & Play
15cablesys.com 800.555.7176 cs@cablesys.com
Plug & Play CablingTraditional Cabling
IdealPlug&Playlocations:
• Enterprise data centers
• Colocation facilities
• Server farms
• Cloud storage networks
• Telecommunication rooms
BezeltoBezel
For high density connectivity between patch panels.
Model#PFA
BezeltoBezel
For connectivity between patch panels.
Model#PFA
1.ChooseConnectivity
BezeltoBezel PFA
BezeltoJumpers PFB
BezeltoOutletBox PFC
2.ChooseCableRating
Riser-ratedOFNR
Plenum-ratedOFNP
Consider fire rating of material and airflow. Most data center
environments can use riser-rated cable (OFNR). Use OFNR in
vertical settings, such as cable running between floors through cable
risers. Use plenum-rated cable (OFNP) in raised flooring systems,
drop ceilings and air handling ducts. Always consult with city or
building authorities for the latest code before deciding the type of
cable to use.
16 Cablesys®
Fiber Plug & Play
Model #
BezeltoJumpers
For connectivity between patch panel and network switch.
Model#PFB
BezeltoOutletBox
For connectivity between patch panel and mobile outlets.
Model#PFC
4.ChooseFibers+Length
Fiber(12 or 24 LC fibers)
Length(3 meters or more)
Consideraccessibilitytoactiveequipmentandthelayoutoftheroom
whenmeasuring,thenrounduptothenearestmeter. Wecancustom
build OM4 up to 550 meters and OM3 up to 300 meters.
3.ChooseBandwidth
10GOM4(for up to 550 meters)
10GOM3(for up to 300 meters)
1G50/125µm(for up to 550 meters)
1G62.5/125µm(for up to 275 meters)
Singlemode
Consider the maximum operating distance to support active
equipment or devices throughout the entire network.
17cablesys.com 800.555.7176 cs@cablesys.com
18 Cablesys®
Fiber Plug & Play
Snap in bezels, DONE!
Installation
Step1.
Install bracket panel. The panel fits
19 inch rack mount widths.
Step2.
Open package.
Step3.
Snap in bezels. Done!
19cablesys.com 800.555.7176 cs@cablesys.com
SupportRearCable
Useafive(5)inchbrackettosupport
cable on the rear of the patch panel.
Cable
Management
Brackets
• Three (3) and five (5) inch depths
• Supports front and rear cable
• Fits 19 inch rack mount widths
20 Cablesys®
Fiber Plug & Play
Bundle6
TM
FiberJumpers
Model#BF6
We pre-bundled and pre-labeled six
(6) fiber jumpers to save you time
and make patching easier.
Pre-bundled
To route cables faster. Wrap is removable.
1.ChooseBandwidth
10GOM4 OFNP*
10GOM3 OFNR
1G50/125µm OFNP*
1G62.5/125µm OFNP*
Singlemode OFNP*
2.ChooseLength
Standard(1 to 15 meters)
Custom(1 meter or more)
*Available in custom length only
21cablesys.com 800.555.7176 cs@cablesys.com
All-in-OnePackage
To save time from opening multiple packages.
Pre-labeled
To easily identify cables.
Online
Retailers
Cablesyshashelped
manycompanies
Plug&Playtheirnetworkcabling!
Financial
Institutions
Cloud
Services
Broadcasting
Networks
Healthcare
Facilities
Educational
Institutions
Leisure
Hospitality
2100EastValenciaDrive,SuiteD,Fullerton, CA92831 USA
800.555.7176 cablesys.com cs@cablesys.com
cablesys.com/pnp
Do-It-Yourself
DataCenter
CablingSystem
Aerospace
Manufacturers
© Copyright 2014, Cablesys. Cablesys and the Cablesys logo are a registered trade name and trademark.
All rights reserved. All other trade names and trademarks are the property of their respective owners.
GCP&P0015

More Related Content

What's hot

Andrew E15S09P78
Andrew E15S09P78Andrew E15S09P78
Andrew E15S09P78
savomir
 
Commscope-Andrew CELLMAX-EXT-CPU
Commscope-Andrew CELLMAX-EXT-CPUCommscope-Andrew CELLMAX-EXT-CPU
Commscope-Andrew CELLMAX-EXT-CPU
savomir
 
Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
 Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc... Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
Thorne & Derrick International
 
Andrew AVA5-50
Andrew AVA5-50Andrew AVA5-50
Andrew AVA5-50
savomir
 
Andrew SFX-ANMR
Andrew SFX-ANMRAndrew SFX-ANMR
Andrew SFX-ANMR
savomir
 
Andrew E15Z01P13
Andrew E15Z01P13Andrew E15Z01P13
Andrew E15Z01P13
savomir
 
Andrew DBXLH-6565A-VTM
Andrew DBXLH-6565A-VTMAndrew DBXLH-6565A-VTM
Andrew DBXLH-6565A-VTM
savomir
 
Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01
Eric Yang
 
Andrew HP10-57W
Andrew HP10-57WAndrew HP10-57W
Andrew HP10-57W
savomir
 
Andrew FXL-780
Andrew FXL-780Andrew FXL-780
Andrew FXL-780
savomir
 
Andrew L4TDM-PSA
Andrew L4TDM-PSAAndrew L4TDM-PSA
Andrew L4TDM-PSA
savomir
 
Andrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2MAndrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2M
savomir
 
Commscope-Andrew FSJ4RN-50B
Commscope-Andrew FSJ4RN-50BCommscope-Andrew FSJ4RN-50B
Commscope-Andrew FSJ4RN-50B
savomir
 
Kaelus DBC0037F1V2-1
Kaelus DBC0037F1V2-1Kaelus DBC0037F1V2-1
Kaelus DBC0037F1V2-1
savomir
 
Panduit Cable Ties & Accerssories
Panduit Cable Ties & AccerssoriesPanduit Cable Ties & Accerssories
Panduit Cable Ties & Accerssories
Thorne & Derrick International
 
Ellis Patents Cable Cleats - Catalogue
Ellis Patents Cable Cleats - CatalogueEllis Patents Cable Cleats - Catalogue
Ellis Patents Cable Cleats - Catalogue
Thorne & Derrick International
 
Andrew APT-DFDM-DB
Andrew APT-DFDM-DBAndrew APT-DFDM-DB
Andrew APT-DFDM-DB
savomir
 
Andrew HP10-107
Andrew HP10-107Andrew HP10-107
Andrew HP10-107
savomir
 
Commscope-Andrew APT-DFDF-DB
Commscope-Andrew APT-DFDF-DBCommscope-Andrew APT-DFDF-DB
Commscope-Andrew APT-DFDF-DB
savomir
 
Commscope-Andrew HP8-59-P1A
Commscope-Andrew HP8-59-P1ACommscope-Andrew HP8-59-P1A
Commscope-Andrew HP8-59-P1A
savomir
 

What's hot (20)

Andrew E15S09P78
Andrew E15S09P78Andrew E15S09P78
Andrew E15S09P78
 
Commscope-Andrew CELLMAX-EXT-CPU
Commscope-Andrew CELLMAX-EXT-CPUCommscope-Andrew CELLMAX-EXT-CPU
Commscope-Andrew CELLMAX-EXT-CPU
 
Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
 Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc... Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
Panduit Panduct PanelMax Shielded Wiring Duct & Noise Shield - EMI/RFI Reduc...
 
Andrew AVA5-50
Andrew AVA5-50Andrew AVA5-50
Andrew AVA5-50
 
Andrew SFX-ANMR
Andrew SFX-ANMRAndrew SFX-ANMR
Andrew SFX-ANMR
 
Andrew E15Z01P13
Andrew E15Z01P13Andrew E15Z01P13
Andrew E15Z01P13
 
Andrew DBXLH-6565A-VTM
Andrew DBXLH-6565A-VTMAndrew DBXLH-6565A-VTM
Andrew DBXLH-6565A-VTM
 
Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01
 
Andrew HP10-57W
Andrew HP10-57WAndrew HP10-57W
Andrew HP10-57W
 
Andrew FXL-780
Andrew FXL-780Andrew FXL-780
Andrew FXL-780
 
Andrew L4TDM-PSA
Andrew L4TDM-PSAAndrew L4TDM-PSA
Andrew L4TDM-PSA
 
Andrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2MAndrew DBXLH-6565A-R2M
Andrew DBXLH-6565A-R2M
 
Commscope-Andrew FSJ4RN-50B
Commscope-Andrew FSJ4RN-50BCommscope-Andrew FSJ4RN-50B
Commscope-Andrew FSJ4RN-50B
 
Kaelus DBC0037F1V2-1
Kaelus DBC0037F1V2-1Kaelus DBC0037F1V2-1
Kaelus DBC0037F1V2-1
 
Panduit Cable Ties & Accerssories
Panduit Cable Ties & AccerssoriesPanduit Cable Ties & Accerssories
Panduit Cable Ties & Accerssories
 
Ellis Patents Cable Cleats - Catalogue
Ellis Patents Cable Cleats - CatalogueEllis Patents Cable Cleats - Catalogue
Ellis Patents Cable Cleats - Catalogue
 
Andrew APT-DFDM-DB
Andrew APT-DFDM-DBAndrew APT-DFDM-DB
Andrew APT-DFDM-DB
 
Andrew HP10-107
Andrew HP10-107Andrew HP10-107
Andrew HP10-107
 
Commscope-Andrew APT-DFDF-DB
Commscope-Andrew APT-DFDF-DBCommscope-Andrew APT-DFDF-DB
Commscope-Andrew APT-DFDF-DB
 
Commscope-Andrew HP8-59-P1A
Commscope-Andrew HP8-59-P1ACommscope-Andrew HP8-59-P1A
Commscope-Andrew HP8-59-P1A
 

Similar to Cablesys Data Center Do It Yourself Cabling System Catalog

6 Tips for Superior Cable Management
6 Tips for Superior Cable Management6 Tips for Superior Cable Management
6 Tips for Superior Cable Management
Amphenol Telect
 
Andrew AVA7-50
Andrew AVA7-50Andrew AVA7-50
Andrew AVA7-50
savomir
 
Commscope-Andrew AVA5-50FX
Commscope-Andrew AVA5-50FXCommscope-Andrew AVA5-50FX
Commscope-Andrew AVA5-50FX
savomir
 
Commscope-Andrew AVA7RK-50
Commscope-Andrew AVA7RK-50Commscope-Andrew AVA7RK-50
Commscope-Andrew AVA7RK-50
savomir
 
us_brochure_fiber-to-the-desktop.pdf
us_brochure_fiber-to-the-desktop.pdfus_brochure_fiber-to-the-desktop.pdf
us_brochure_fiber-to-the-desktop.pdf
OliviaJohn16
 
Commscope-Andrew LDF5-50A
Commscope-Andrew LDF5-50ACommscope-Andrew LDF5-50A
Commscope-Andrew LDF5-50A
savomir
 
Telecom cable ls cable & system- tnhhkimxuan
Telecom cable ls cable & system- tnhhkimxuanTelecom cable ls cable & system- tnhhkimxuan
Telecom cable ls cable & system- tnhhkimxuan
Ngan TNHH
 
Automated Systems Design (ASD)
Automated Systems Design (ASD)Automated Systems Design (ASD)
Automated Systems Design (ASD)
Julie Fletcher
 
PROFINET network qualification Peter Thomas - oct 2015
PROFINET network qualification   Peter Thomas - oct 2015PROFINET network qualification   Peter Thomas - oct 2015
PROFINET network qualification Peter Thomas - oct 2015
PROFIBUS and PROFINET InternationaI - PI UK
 
Profinet network qualification - Peter Thomas
Profinet network qualification - Peter ThomasProfinet network qualification - Peter Thomas
Profinet network qualification - Peter Thomas
PROFIBUS and PROFINET InternationaI - PI UK
 
WLAN
WLANWLAN
Andrew AVA6-50
Andrew AVA6-50Andrew AVA6-50
Andrew AVA6-50
savomir
 
Andrew AEP412
Andrew AEP412Andrew AEP412
Andrew AEP412
savomir
 
cisco-ws-c3650-48fwd-s-datasheet.pdf
cisco-ws-c3650-48fwd-s-datasheet.pdfcisco-ws-c3650-48fwd-s-datasheet.pdf
cisco-ws-c3650-48fwd-s-datasheet.pdf
Hi-Network.com
 
Andrew LDF4-50A
Andrew LDF4-50AAndrew LDF4-50A
Andrew LDF4-50A
savomir
 
cisco-ws-c3650-24pws-s-datasheet.pdf
cisco-ws-c3650-24pws-s-datasheet.pdfcisco-ws-c3650-24pws-s-datasheet.pdf
cisco-ws-c3650-24pws-s-datasheet.pdf
Hi-Network.com
 
PACE-IT: Network Cabling (part 1) - N10 006
PACE-IT: Network Cabling (part 1) - N10 006 PACE-IT: Network Cabling (part 1) - N10 006
PACE-IT: Network Cabling (part 1) - N10 006
Pace IT at Edmonds Community College
 
Commscope-Andrew LDF12-50
Commscope-Andrew LDF12-50Commscope-Andrew LDF12-50
Commscope-Andrew LDF12-50
savomir
 
Commscope-Andrew FXL-540
Commscope-Andrew FXL-540Commscope-Andrew FXL-540
Commscope-Andrew FXL-540
savomir
 

Similar to Cablesys Data Center Do It Yourself Cabling System Catalog (20)

6 Tips for Superior Cable Management
6 Tips for Superior Cable Management6 Tips for Superior Cable Management
6 Tips for Superior Cable Management
 
Andrew AVA7-50
Andrew AVA7-50Andrew AVA7-50
Andrew AVA7-50
 
Commscope-Andrew AVA5-50FX
Commscope-Andrew AVA5-50FXCommscope-Andrew AVA5-50FX
Commscope-Andrew AVA5-50FX
 
Commscope-Andrew AVA7RK-50
Commscope-Andrew AVA7RK-50Commscope-Andrew AVA7RK-50
Commscope-Andrew AVA7RK-50
 
us_brochure_fiber-to-the-desktop.pdf
us_brochure_fiber-to-the-desktop.pdfus_brochure_fiber-to-the-desktop.pdf
us_brochure_fiber-to-the-desktop.pdf
 
Commscope-Andrew LDF5-50A
Commscope-Andrew LDF5-50ACommscope-Andrew LDF5-50A
Commscope-Andrew LDF5-50A
 
Telecom cable ls cable & system- tnhhkimxuan
Telecom cable ls cable & system- tnhhkimxuanTelecom cable ls cable & system- tnhhkimxuan
Telecom cable ls cable & system- tnhhkimxuan
 
Automated Systems Design (ASD)
Automated Systems Design (ASD)Automated Systems Design (ASD)
Automated Systems Design (ASD)
 
PROFINET network qualification Peter Thomas - oct 2015
PROFINET network qualification   Peter Thomas - oct 2015PROFINET network qualification   Peter Thomas - oct 2015
PROFINET network qualification Peter Thomas - oct 2015
 
Profinet network qualification - Peter Thomas
Profinet network qualification - Peter ThomasProfinet network qualification - Peter Thomas
Profinet network qualification - Peter Thomas
 
WLAN
WLANWLAN
WLAN
 
Andrew AVA6-50
Andrew AVA6-50Andrew AVA6-50
Andrew AVA6-50
 
03 profibus design_good_practices
03 profibus design_good_practices03 profibus design_good_practices
03 profibus design_good_practices
 
Andrew AEP412
Andrew AEP412Andrew AEP412
Andrew AEP412
 
cisco-ws-c3650-48fwd-s-datasheet.pdf
cisco-ws-c3650-48fwd-s-datasheet.pdfcisco-ws-c3650-48fwd-s-datasheet.pdf
cisco-ws-c3650-48fwd-s-datasheet.pdf
 
Andrew LDF4-50A
Andrew LDF4-50AAndrew LDF4-50A
Andrew LDF4-50A
 
cisco-ws-c3650-24pws-s-datasheet.pdf
cisco-ws-c3650-24pws-s-datasheet.pdfcisco-ws-c3650-24pws-s-datasheet.pdf
cisco-ws-c3650-24pws-s-datasheet.pdf
 
PACE-IT: Network Cabling (part 1) - N10 006
PACE-IT: Network Cabling (part 1) - N10 006 PACE-IT: Network Cabling (part 1) - N10 006
PACE-IT: Network Cabling (part 1) - N10 006
 
Commscope-Andrew LDF12-50
Commscope-Andrew LDF12-50Commscope-Andrew LDF12-50
Commscope-Andrew LDF12-50
 
Commscope-Andrew FXL-540
Commscope-Andrew FXL-540Commscope-Andrew FXL-540
Commscope-Andrew FXL-540
 

Cablesys Data Center Do It Yourself Cabling System Catalog

  • 3. 5cablesys.com 800.555.7176 cs@cablesys.com 200 Bin Rangrequencmulative % 0.02 35 18% 0.04 36 36% 0.06 40 56% 0.08 30 71% 0.1 25 83% 0.12 24 95% 0.14 3 97% 0.16 4 99% 0.18 2 100% 0.2 1 100% 0.22 0 100% 0.24 0 100% 0.26 0 100% 0.28 0 100% 0.3 0 100% 35 36 40 30 25 24 3 4 2 1 0 0 0 0 0 18% 36% 56% 71% 83% 95% 97% 99% 100% 100% 100% 100% 100% 100% 100% 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.28 0.3 Performance Testedupto5.7dBHeadroom NEXT@Remote 120 100 80 60 40 20 0 50 100 150 200 250 12-36 12-45 12-78 36-45 36-78 45-78 Limit Testedupto<=0.1dBInsertionLoss ILHistogram • OM3MultimodefibertestedperTIA® specification • 83%tested<=0.1dB,99%tested<=0.16dB • ExceedsANSI/TIA568-C.3industrystandard • Beatstheindustry’saverageof0.75dB • ComplieswithIEEE802.3andIEC-60793-2-10standards 45 40 35 30 25 20 15 10 5 0 Frequency • CAT6UTPtestedperTIAPermanentLinkspecification • ExceedsANSI/TIA568-C.2industrystandard • UL® listedandETL® verified dB 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% ILBinRange Fibercount 12page4page Copper Fiber
  • 4. 6 Cablesys® Copper Plug & Play CopperPlug&Play CablingSystem Features Pre-terminated • CAT 6A, CAT 6 and CAT 5e • To T-568-A or B wiring Pre-bundled • With durable PEP retardant yarn • Six (6) cables per bundle Pre-labeled • On cables, bundles and cartons • To customers’ requirement Pre-tested • To ANSI/TIA 568-C.2 industry standard • 15 year performance warranty Pre-kitted • Sorting and packing products • To customers’ requirement
  • 5. 7cablesys.com 800.555.7176 cs@cablesys.com IdealPlug&Playlocations: • Enterprise data centers • Colocation facilities • Server farms • Cloud storage networks • Telecommunication rooms Plug & Play CablingTraditional Cabling
  • 6. BezeltoBezel For connectivity between patch panels. Model#PCA BezeltoModularPlugs For connectivity between patch panel and network switch. Model#PCB 1.ChooseConnectivity BezeltoBezel PCA BezeltoModularPlugs PCB BezeltoMobileBox PCC BezeltoOutletBox PCC 2.ChooseCableRating Riser-ratedCMR Plenum-ratedCMP Consider fire rating of material and airflow. Most data center environments can use riser-rated cable (CMR). Use CMR in vertical settings, such as cable running between floors through cable risers. Use plenum-rated cable (CMP) in raised flooring systems, drop ceilings and air handling ducts. Always consult with city or building authorities for the latest code before deciding the type of cable. 8 Cablesys® Copper Plug & Play Model #
  • 7. BezeltoMobileBox For connectivity between patch panel and mobile outlets. Model#PCC BezeltoOutletBox For connectivity between patch panel and mobile outlets. Model#PCC 4.ChooseLength Standard(25, 50, 75 and 100 feet) Custom(10 to 295 feet) Consideraccessibilitytoactiveequipmentandthelayoutoftheroom when measuring, then round up to the nearest foot. We pre-build and stock cable assemblies in standard lengths to help reduce our lead time and ship orders faster. We also custom build up to 295 feet per TIA standard. 3.ChooseBandwidth 10GCAT6AShielded(FTP) 10GCAT6AUnshielded(UTP) 1GCAT6eUnshielded(UTP) VoIPCAT5eUnshielded(UTP) Consider what active equipment or devices will be supported throughout the entire network. Use Foiled Twisted Pair (FTP) in environments with high Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI). Use Unshielded Twisted Pair (UTP) in environments with low interference. 9cablesys.com 800.555.7176 cs@cablesys.com
  • 8. 10 Cablesys® Copper Plug & Play Installation Step1. Install bracket panel. The panel fits 19 inch rack mount widths. Step2. Open package. Step3. Snap in bezels. Done!
  • 9. 11cablesys.com 800.555.7176 cs@cablesys.com SupportRearCable Useafive(5)inchbrackettosupport cable on the rear of the patch panel. Cable Management Brackets • Three (3) and five (5) inch depths • Supports front and rear cable • Fits 19 inch rack mount widths
  • 10. 12 Cablesys® Copper Plug & Play Bundle6 TM PatchCords Model#BC6 We pre-bundled and pre-labeled six (6) copper patch cords to save you time and make patching easier. 1.ChooseBandwidth 10GCAT6AShielded(FTP) 1GCAT6eUnshielded(UTP) VoIPCAT5eUnshielded(UTP)* 2.ChooseLength Standard(7, 10, and 15 feet) Custom(5 to 295 feet) *Available in custom length only Pre-bundled To route cables faster. Wrap is removable.
  • 11. 13cablesys.com 800.555.7176 cs@cablesys.com All-in-OnePackage To save time from opening multiple packages. Pre-labeled To easily identify cables.
  • 12. FiberPlug&Play CablingSystem Features Pre-terminated • LC fiber connectors • 15 year performance warranty Pre-bundled • With durable PEP retardant yarn • Six (6) cables per bundle Pre-labeled • On cables, bundles and cartons • To customers’ requirement Pre-tested • To ANSI/TIA 568-C.3 industry standard • 0.2dB or less Insertion Loss Pre-kitted • Sorting and packing products • To customers’ requirement 14 Cablesys® Fiber Plug & Play
  • 13. 15cablesys.com 800.555.7176 cs@cablesys.com Plug & Play CablingTraditional Cabling IdealPlug&Playlocations: • Enterprise data centers • Colocation facilities • Server farms • Cloud storage networks • Telecommunication rooms
  • 14. BezeltoBezel For high density connectivity between patch panels. Model#PFA BezeltoBezel For connectivity between patch panels. Model#PFA 1.ChooseConnectivity BezeltoBezel PFA BezeltoJumpers PFB BezeltoOutletBox PFC 2.ChooseCableRating Riser-ratedOFNR Plenum-ratedOFNP Consider fire rating of material and airflow. Most data center environments can use riser-rated cable (OFNR). Use OFNR in vertical settings, such as cable running between floors through cable risers. Use plenum-rated cable (OFNP) in raised flooring systems, drop ceilings and air handling ducts. Always consult with city or building authorities for the latest code before deciding the type of cable to use. 16 Cablesys® Fiber Plug & Play Model #
  • 15. BezeltoJumpers For connectivity between patch panel and network switch. Model#PFB BezeltoOutletBox For connectivity between patch panel and mobile outlets. Model#PFC 4.ChooseFibers+Length Fiber(12 or 24 LC fibers) Length(3 meters or more) Consideraccessibilitytoactiveequipmentandthelayoutoftheroom whenmeasuring,thenrounduptothenearestmeter. Wecancustom build OM4 up to 550 meters and OM3 up to 300 meters. 3.ChooseBandwidth 10GOM4(for up to 550 meters) 10GOM3(for up to 300 meters) 1G50/125µm(for up to 550 meters) 1G62.5/125µm(for up to 275 meters) Singlemode Consider the maximum operating distance to support active equipment or devices throughout the entire network. 17cablesys.com 800.555.7176 cs@cablesys.com
  • 16. 18 Cablesys® Fiber Plug & Play Snap in bezels, DONE! Installation Step1. Install bracket panel. The panel fits 19 inch rack mount widths. Step2. Open package. Step3. Snap in bezels. Done!
  • 17. 19cablesys.com 800.555.7176 cs@cablesys.com SupportRearCable Useafive(5)inchbrackettosupport cable on the rear of the patch panel. Cable Management Brackets • Three (3) and five (5) inch depths • Supports front and rear cable • Fits 19 inch rack mount widths
  • 18. 20 Cablesys® Fiber Plug & Play Bundle6 TM FiberJumpers Model#BF6 We pre-bundled and pre-labeled six (6) fiber jumpers to save you time and make patching easier. Pre-bundled To route cables faster. Wrap is removable. 1.ChooseBandwidth 10GOM4 OFNP* 10GOM3 OFNR 1G50/125µm OFNP* 1G62.5/125µm OFNP* Singlemode OFNP* 2.ChooseLength Standard(1 to 15 meters) Custom(1 meter or more) *Available in custom length only
  • 19. 21cablesys.com 800.555.7176 cs@cablesys.com All-in-OnePackage To save time from opening multiple packages. Pre-labeled To easily identify cables.
  • 20. Online Retailers Cablesyshashelped manycompanies Plug&Playtheirnetworkcabling! Financial Institutions Cloud Services Broadcasting Networks Healthcare Facilities Educational Institutions Leisure Hospitality 2100EastValenciaDrive,SuiteD,Fullerton, CA92831 USA 800.555.7176 cablesys.com cs@cablesys.com cablesys.com/pnp Do-It-Yourself DataCenter CablingSystem Aerospace Manufacturers © Copyright 2014, Cablesys. Cablesys and the Cablesys logo are a registered trade name and trademark. All rights reserved. All other trade names and trademarks are the property of their respective owners. GCP&P0015