Maestro 3000®
Cardiac Ablation System
Boston Scientific Corporation
150 Baytech Drive
San Jose, CA. 95134 USA
www.bostonscientific.com
For more information about the
Maestro 3000®
System, call
Boston Scientific Customer
Service at 1-888-272-1001.
EPT-10515-02_04/2010
© 2010 Boston Scientific Corporation
or its affiliates. All rights reserved.
Precision and Control...Enhanced.
The next generation in performance
Intended Use/Indications for Use:
The Maestro 3000®
Cardiac Ablation System is indicated for use, in cardiac ablation procedures, with standard and high-power BSC cardiac ablation catheters such that the physician is
referred to the individual Instructions for Use for catheter compatibility to the Maestro 3000 Cardiac Ablation System.
Note: Refer to the individual Directions for Use for catheter compatibility to the Maestro 3000 Cardiac Ablation System. It is also important to carefully review the specific indications,
contraindications, warnings, precautions and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System.
Contraindications:
Note:The contraindications listed in the catheter Directions For Use also apply to the use with the Maestro 3000 Cardiac Ablation System. Carefully review the specific indications,
contraindications, warnings, precautions, and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System.
Warnings and Precautions:
The following warnings and precautions apply only to the Maestro 3000®
Cardiac Ablation Controller and its accessories. Refer to the appropriate catheter Directions for Use for Warnings,
Precautions, and Adverse Events related to the catheter.
Warnings:
Before operating the System, carefully review these warnings:
•The displayed temperature is not the maximum tissue temperature. Do not set the maximum temperature higher than 80°C.
• Pacemakers and implantable cardioverter/defibrillators can be adversely affected by RF signals. It is important to:
• Retain temporary external sources of pacing available during ablation.
• Reprogram the pacing system temporarily to minimum setting or 000 mode to reduce risk of inappropriate pacing.
• Exercise extreme caution during ablation when in close proximity to atrial or ventricular permanent pacing leads.
• Perform complete pacing system analysis on all patients after ablation.
•The possibility of skin burns to the patient may exist whenever a high power Catheter is utilized.
•The use of Catheters or cables with unprotected male pin connectors presents a risk of electrical hazard. Inadvertent attachment of pin connectors to power supply sockets or connectors
could result in electrocution of the patient or operator. Misconnection of the pins could also lead to inappropriate delivery of RF current through a band electrode.The users of components
with unprotected male pin connectors must exercise extreme caution during device setup to prevent patient or operator injury. Unused pins should be secured so that they do not
inadvertently touch other equipment or surfaces. Never insert pins into MAINS outlets or into any equipment other than systems providing patient electrical isolation in accordance with
IEC 60601-1.
•The Pod output connection labeled “Recorder” must only be connected to a medically isolated recording system.
• Grounding reliability can only be achieved when the power supply cord is connected to a receptacle marked “Hospital Only” or “Hospital Grade”.
• Do not use an extension cord with the system and do not connect the system’s power supply cord to an additional multiple portable socket.
• Do not connect items that are not specified as a part of the system.
• Accessory equipment connected to the analog and digital interfaces must be certified to the respective IEC standards (i.e. IEC 950 for data processing equipment and IEC 60601-1 for
medical equipment). Furthermore, all configurations shall comply with the system standard IEC 60601-1-1. Everybody who connects additional equipment to the signal input ports or
signal output ports configures a medical system, and it therefore responsible that the system complies with the requirements of the system standard IEC 60601-1-1. If in doubt, consult the
technical services department or your local BSC representative.
• If a Booker Box device is used with the system, it should be used with a DIP electrode that is separate from the DIP electrode used by the Controller.
• Electromagnetic interference (EMI) produced by the Controller during delivery of RF power may adversely affect the performance of other equipment.The user is encouraged to try to
correct the interference by one or more of the following measures: Reorient or relocate the receiving device, Increase the separation between the equipment, Connect the equipment into
an outlet on a circuit different from that to which the other device(s) are connected. Consult your local BSC field service technician for help. Failure of the RF generator could result in an
unintended increase of output power.
•The use of accessories, transducers and cables other than those specified may result in increased electromagnetic emissions or decreased electromagnetic immunity of the Maestro 3000
Cardiac Ablation System.”
• Components of the Maestro 3000 Cardiac Ablation System should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the Maestro
3000 Cardiac Ablation System should be observed to verify normal operation in the configuration in which it will be used.
• Failure of the Maestro 3000 Cardiac Ablation System could result in an unintended increase of output power.
Precautions:
Review the following precautions before using the System:
• Do not attempt to operate the BSC Maestro 3000 Cardiac Ablation System before thoroughly reading this Operator’s Manual.
•The “Impedance” Display of the Controller should be continuously monitored during RF power delivery. If a sudden rise in impedance is noted, RF power delivery should be discontinued.
• Adequate filtering must be used to allow continuous monitoring of the surface electrocardiogram (ECG) during RF power applications.
• Read and follow the disposable Dispersive Indifferent Patch (DIP) Electrode manufacturer’s instructions for use.The use of DIP Electrodes, which meet or exceed ANSI/AAMI HF-18
requirements, is required. BSC recommends the use of Valley Labs DIP Electrodes, BSC model number 354.
•The entire area of the DIP Electrode should be reliably attached to the patient’s body. Placement on the patient’s back is recommended.
• When using high-power Catheters, it is required that two DIP electrodes be used.
• Apparent low power output or higher than typical impedance measurements may be indicative of faulty DIP Electrode application or failure of an electrical lead. Check the application of
the DIP Electrode and all electrical connections before continuing or selecting higher power outputs.
• Skin-to-skin contact (for example between the arms and body of the patient) should be avoided, for example by insertion of dry gauze.
• When physiological monitoring equipment is used on the same patient, any monitoring electrodes should be placed as far as possible from the ablation electrodes. Needle monitoring
electrodes are not recommended. Monitoring systems incorporating high frequency current-limiting devices are recommended.
•The long-term risks of protracted fluoroscopy have not been established. Careful consideration must therefore be given for the use of the device in prepubescent children. Furthermore, the
risk/benefit in asymptomatic patients has not been studied.
•The cables connecting the Catheter to the System should be positioned in such a way that contact with the patient or other leads is avoided.
•The Controller is capable of delivering significant electrical power. Patient or operator injury can result from improper handling of the Catheter and DIP Electrode, particularly when
operating the device. During power delivery, the patient should not be allowed to come in contact with grounded metal surfaces.The use of antistatic sheeting is recommended.
•The risk of igniting flammable gases or other materials is inherent in the application of RF power. Precautions must be taken to restrict flammable materials from the ablation site.
• Do not immerse the Controller, the Remote or accessories in any liquid. Avoid caustic or abrasive cleaners.
• Use of non-flammable agents for cleaning and disinfection is recommended. Flammable agents or solvents used for cleaning and disinfection should be allowed to evaporate before high-
frequency surgery.
• Regularly inspect re-usable cables and accessories. In particular, cables and accessories should be checked for possible damage to the insulation.
• Boston Scientific relies on the physician to determine, assess and communicate to the individual patient all foreseeable risks of the cardiac ablation procedure.
•The System is designed to be connected to a single ablation catheter at a time. Do not attempt to connect multiple ablation catheters into the Pod, as this will cause unforeseen risks.
• BSC recommends that the Controller and Remote Control units be powered off at the end of each procedure in order to ensure that the self-test is performed before the next procedure.
•The power selected should be as low as possible for the intended purpose.
•The Pod is not intended to be sterilized and should remain outside of the sterile field.
•The Maestro 3000 Cardiac Ablation System needs special precautions regarding EMC and needs to be installed and put into service
according to the EMC information provided in Section 7.2.
• Portable and mobile RF communications equipment can affect the Maestro 3000 Cardiac Ablation System. It is advised not to use this
equipment in proximity to the Maestro 3000 Cardiac Ablation System.
• Pins of connectors identified with the ESD warning symbol should not be touched and connections should not be made to these
connectors unless ESD precautionary procedures are used.
• It is recommended that all staff involved in the assembly and/or installation of the Maestro 3000 Cardiac Ablation System receive an
explanation of the ESD warning symbol and training in ESD precautionary procedures. Please refer to Section 6.4 for ESD Procedures
Adverse Events:
The potential risks or discomforts that may be associated with electrosurgical procedures can vary greatly in frequency and severity, and
may necessitate additional medical intervention, including surgery. Carefully review the specific indications, contraindications, warnings,
precautions, and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System.
Maestro 3000 System DFU (90487630_AB_EN)
Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician.
See the appropriate technical manuals for detailed information regarding instructions for use,
indications, contraindications, warnings and precautions, and potential adverse events.
Maestro 3000®
Cardiac Ablation System:
The best of the EPT-1000XP™ Cardiac Ablation System with enhanced clinical utility
“View Settings”
button parametersProgrammable memory buttons
Descriptive diagnostic
messages“Avg/Max” value displays
The best of the EPT-1000XP System Added clinical utilityExpanded ease-of-use
Remote Control Unit
• Intuitive user interface with no hidden or embedded menus
• Powers a complete portfolio of Blazer®
Bidirectional
Temperature Ablation Catheters
	 – Blazer Prime®
XP Catheter and Blazer Prime®
HTD Catheter
	 – Blazer®
II Catheter, Blazer®
II HTD Catheter, and
	 Blazer®
II XP Catheter
	 – Chilli II®
Cooled Ablation Catheter
• Any catheter that currently works with the
EPT-1000XP System will also work with
the Maestro 3000 System
• Up to 100W RF energy for versatility
and expanded performance
• Optional remote control unit can be placed up to 75 feet
from the master unit, which may allow for operation
outside radiation exposure
• 5 programmable memory buttons let you save
frequently used ablation parameters and easily return
to starting parameters
• Descriptive diagnostic messages aid
in troubleshooting
• Real-time impedance monitoring
	 – Provides an indicator of tissue type (endocardial vs
venous) and tissue/tip contact to enhance catheter
positioning
• New “Noise Reduction” technology
	 – Low pass filters designed to reduce electronic
interference and provide clear electrograms
	 – Optional remote control unit eliminates complex
cabling to help reduce noise
• “Avg/Max” value displays for temperature, impedance
and time provide valuable lesion formation feedback
• “View Settings” button lets you see set points
during RF delivery

More Related Content

What's hot

IEC 60601-1 Medical Power Safety Requirement
IEC 60601-1 Medical Power Safety RequirementIEC 60601-1 Medical Power Safety Requirement
IEC 60601-1 Medical Power Safety Requirement
FSP Technology Inc.
 
Leadless pacemaker
Leadless pacemakerLeadless pacemaker
Leadless pacemaker
Vatsal Kayal
 
Chronic stable angina
Chronic stable angina Chronic stable angina
Chronic stable angina
sxs44
 
I g5a manual_v2.4_ 110131
I g5a manual_v2.4_ 110131I g5a manual_v2.4_ 110131
I g5a manual_v2.4_ 110131
Chan Suk
 
Defi6 catalog
Defi6 catalogDefi6 catalog
I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131
lenguyen277
 
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
Tenmars Việt Nam
 
I g5a
I g5aI g5a
Infini solar 10kw-manual
Infini solar 10kw-manualInfini solar 10kw-manual
Infini solar 10kw-manual
Naveed Ahmed
 
Sv ig5a manual dienhathe.vn
Sv ig5a manual dienhathe.vnSv ig5a manual dienhathe.vn
Sv ig5a manual dienhathe.vn
Dien Ha The
 
Sv i h
Sv i hSv i h
Hướng dẫn sử dụng Testo 760-1
Hướng dẫn sử dụng Testo 760-1Hướng dẫn sử dụng Testo 760-1
Hướng dẫn sử dụng Testo 760-1
Tenmars Việt Nam
 
Infini solar v 1kw 5kw manual
Infini solar v 1kw 5kw manualInfini solar v 1kw 5kw manual
Infini solar v 1kw 5kw manual
Naveed Ahmed
 
Sv i p5a-manual_(english)
Sv i p5a-manual_(english)Sv i p5a-manual_(english)
Sv i p5a-manual_(english)
Toàn Huỳnh
 
756 i e5_eng_081014
756 i e5_eng_081014756 i e5_eng_081014
756 i e5_eng_081014
Toàn Huỳnh
 

What's hot (15)

IEC 60601-1 Medical Power Safety Requirement
IEC 60601-1 Medical Power Safety RequirementIEC 60601-1 Medical Power Safety Requirement
IEC 60601-1 Medical Power Safety Requirement
 
Leadless pacemaker
Leadless pacemakerLeadless pacemaker
Leadless pacemaker
 
Chronic stable angina
Chronic stable angina Chronic stable angina
Chronic stable angina
 
I g5a manual_v2.4_ 110131
I g5a manual_v2.4_ 110131I g5a manual_v2.4_ 110131
I g5a manual_v2.4_ 110131
 
Defi6 catalog
Defi6 catalogDefi6 catalog
Defi6 catalog
 
I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131I g5a manual_v2.4_+110131
I g5a manual_v2.4_+110131
 
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
Hướng dẫn sử dụng đồng hồ vạn năng Testo 760
 
I g5a
I g5aI g5a
I g5a
 
Infini solar 10kw-manual
Infini solar 10kw-manualInfini solar 10kw-manual
Infini solar 10kw-manual
 
Sv ig5a manual dienhathe.vn
Sv ig5a manual dienhathe.vnSv ig5a manual dienhathe.vn
Sv ig5a manual dienhathe.vn
 
Sv i h
Sv i hSv i h
Sv i h
 
Hướng dẫn sử dụng Testo 760-1
Hướng dẫn sử dụng Testo 760-1Hướng dẫn sử dụng Testo 760-1
Hướng dẫn sử dụng Testo 760-1
 
Infini solar v 1kw 5kw manual
Infini solar v 1kw 5kw manualInfini solar v 1kw 5kw manual
Infini solar v 1kw 5kw manual
 
Sv i p5a-manual_(english)
Sv i p5a-manual_(english)Sv i p5a-manual_(english)
Sv i p5a-manual_(english)
 
756 i e5_eng_081014
756 i e5_eng_081014756 i e5_eng_081014
756 i e5_eng_081014
 

Similar to Boston Scientific Maestro 3000

Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
Igor Tabulynsky
 
Lg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2acLg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2ac
febriyansyah98
 
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Arturo Nava Hernandez
 
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Portal Eletrônica
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm
tecxel
 
Instructinon manual Mega
Instructinon manual  MegaInstructinon manual  Mega
Instructinon manual Mega
Toàn Huỳnh
 
13 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml1013 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml10
Cesar1alex
 
Pixel cp operators manual
Pixel cp operators manualPixel cp operators manual
Pixel cp operators manual
Alexandra Cardenas
 
Sistema de monitorització de mesures elèctriques
Sistema de monitorització de mesures elèctriques Sistema de monitorització de mesures elèctriques
Sistema de monitorització de mesures elèctriques
Tomeu Capó Capó
 
Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760
Tenmars Việt Nam
 
Bionet bm3 manual de servicio
Bionet bm3 manual de servicioBionet bm3 manual de servicio
Bionet bm3 manual de servicio
Juan Pastrana Baleon
 
Sharp 32 pulg 32c24
Sharp 32 pulg 32c24Sharp 32 pulg 32c24
Sharp 32 pulg 32c24
Irwing Sanchez
 
Electrical Measurement Safety and Best Practices Webinar Presented by Fluke
Electrical Measurement Safety and Best Practices Webinar Presented by FlukeElectrical Measurement Safety and Best Practices Webinar Presented by Fluke
Electrical Measurement Safety and Best Practices Webinar Presented by Fluke
Transcat
 
Catalog FR-A700 Instruction manual (applied)-Beeteco.com
Catalog FR-A700 Instruction manual (applied)-Beeteco.comCatalog FR-A700 Instruction manual (applied)-Beeteco.com
Catalog FR-A700 Instruction manual (applied)-Beeteco.com
Beeteco
 
Ecg machine
Ecg machineEcg machine
Ecg machine
JahinAhmed3
 
Lg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01uLg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01u
edy rod
 
Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200
CTY TNHH HẠO PHƯƠNG
 
Lcr 800 user manual (1)
Lcr 800 user manual (1)Lcr 800 user manual (1)
Lcr 800 user manual (1)
Slim Abid
 
Hướng dẫn sử dụng Testo 770-1
Hướng dẫn sử dụng Testo 770-1Hướng dẫn sử dụng Testo 770-1
Hướng dẫn sử dụng Testo 770-1
Tenmars Việt Nam
 
Huong dan su dung Teso 770-1
Huong dan su dung Teso 770-1Huong dan su dung Teso 770-1
Huong dan su dung Teso 770-1
Tenmars Việt Nam
 

Similar to Boston Scientific Maestro 3000 (20)

Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
Standard safetyhighvoltageinstallationsonboardshipsspecialeditionmarch2012
 
Lg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2acLg+42 lt360c+chassis+lb2ac
Lg+42 lt360c+chassis+lb2ac
 
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
Lg 42lw5700 da-chassis_lt12c_mfl67007911_1103-rev00
 
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
Manual de serviço TV LED LG 22LN4050TB chassis LB35A.
 
67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm67711911(lj36 b)42ln5460 sm
67711911(lj36 b)42ln5460 sm
 
Instructinon manual Mega
Instructinon manual  MegaInstructinon manual  Mega
Instructinon manual Mega
 
13 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml1013 l m100-150,cl13m10-15,14ml10
13 l m100-150,cl13m10-15,14ml10
 
Pixel cp operators manual
Pixel cp operators manualPixel cp operators manual
Pixel cp operators manual
 
Sistema de monitorització de mesures elèctriques
Sistema de monitorització de mesures elèctriques Sistema de monitorització de mesures elèctriques
Sistema de monitorització de mesures elèctriques
 
Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760
 
Bionet bm3 manual de servicio
Bionet bm3 manual de servicioBionet bm3 manual de servicio
Bionet bm3 manual de servicio
 
Sharp 32 pulg 32c24
Sharp 32 pulg 32c24Sharp 32 pulg 32c24
Sharp 32 pulg 32c24
 
Electrical Measurement Safety and Best Practices Webinar Presented by Fluke
Electrical Measurement Safety and Best Practices Webinar Presented by FlukeElectrical Measurement Safety and Best Practices Webinar Presented by Fluke
Electrical Measurement Safety and Best Practices Webinar Presented by Fluke
 
Catalog FR-A700 Instruction manual (applied)-Beeteco.com
Catalog FR-A700 Instruction manual (applied)-Beeteco.comCatalog FR-A700 Instruction manual (applied)-Beeteco.com
Catalog FR-A700 Instruction manual (applied)-Beeteco.com
 
Ecg machine
Ecg machineEcg machine
Ecg machine
 
Lg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01uLg 32 lk330u +chasis+ld01u
Lg 32 lk330u +chasis+ld01u
 
Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200
 
Lcr 800 user manual (1)
Lcr 800 user manual (1)Lcr 800 user manual (1)
Lcr 800 user manual (1)
 
Hướng dẫn sử dụng Testo 770-1
Hướng dẫn sử dụng Testo 770-1Hướng dẫn sử dụng Testo 770-1
Hướng dẫn sử dụng Testo 770-1
 
Huong dan su dung Teso 770-1
Huong dan su dung Teso 770-1Huong dan su dung Teso 770-1
Huong dan su dung Teso 770-1
 

Boston Scientific Maestro 3000

  • 1. Maestro 3000® Cardiac Ablation System Boston Scientific Corporation 150 Baytech Drive San Jose, CA. 95134 USA www.bostonscientific.com For more information about the Maestro 3000® System, call Boston Scientific Customer Service at 1-888-272-1001. EPT-10515-02_04/2010 © 2010 Boston Scientific Corporation or its affiliates. All rights reserved. Precision and Control...Enhanced. The next generation in performance Intended Use/Indications for Use: The Maestro 3000® Cardiac Ablation System is indicated for use, in cardiac ablation procedures, with standard and high-power BSC cardiac ablation catheters such that the physician is referred to the individual Instructions for Use for catheter compatibility to the Maestro 3000 Cardiac Ablation System. Note: Refer to the individual Directions for Use for catheter compatibility to the Maestro 3000 Cardiac Ablation System. It is also important to carefully review the specific indications, contraindications, warnings, precautions and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System. Contraindications: Note:The contraindications listed in the catheter Directions For Use also apply to the use with the Maestro 3000 Cardiac Ablation System. Carefully review the specific indications, contraindications, warnings, precautions, and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System. Warnings and Precautions: The following warnings and precautions apply only to the Maestro 3000® Cardiac Ablation Controller and its accessories. Refer to the appropriate catheter Directions for Use for Warnings, Precautions, and Adverse Events related to the catheter. Warnings: Before operating the System, carefully review these warnings: •The displayed temperature is not the maximum tissue temperature. Do not set the maximum temperature higher than 80°C. • Pacemakers and implantable cardioverter/defibrillators can be adversely affected by RF signals. It is important to: • Retain temporary external sources of pacing available during ablation. • Reprogram the pacing system temporarily to minimum setting or 000 mode to reduce risk of inappropriate pacing. • Exercise extreme caution during ablation when in close proximity to atrial or ventricular permanent pacing leads. • Perform complete pacing system analysis on all patients after ablation. •The possibility of skin burns to the patient may exist whenever a high power Catheter is utilized. •The use of Catheters or cables with unprotected male pin connectors presents a risk of electrical hazard. Inadvertent attachment of pin connectors to power supply sockets or connectors could result in electrocution of the patient or operator. Misconnection of the pins could also lead to inappropriate delivery of RF current through a band electrode.The users of components with unprotected male pin connectors must exercise extreme caution during device setup to prevent patient or operator injury. Unused pins should be secured so that they do not inadvertently touch other equipment or surfaces. Never insert pins into MAINS outlets or into any equipment other than systems providing patient electrical isolation in accordance with IEC 60601-1. •The Pod output connection labeled “Recorder” must only be connected to a medically isolated recording system. • Grounding reliability can only be achieved when the power supply cord is connected to a receptacle marked “Hospital Only” or “Hospital Grade”. • Do not use an extension cord with the system and do not connect the system’s power supply cord to an additional multiple portable socket. • Do not connect items that are not specified as a part of the system. • Accessory equipment connected to the analog and digital interfaces must be certified to the respective IEC standards (i.e. IEC 950 for data processing equipment and IEC 60601-1 for medical equipment). Furthermore, all configurations shall comply with the system standard IEC 60601-1-1. Everybody who connects additional equipment to the signal input ports or signal output ports configures a medical system, and it therefore responsible that the system complies with the requirements of the system standard IEC 60601-1-1. If in doubt, consult the technical services department or your local BSC representative. • If a Booker Box device is used with the system, it should be used with a DIP electrode that is separate from the DIP electrode used by the Controller. • Electromagnetic interference (EMI) produced by the Controller during delivery of RF power may adversely affect the performance of other equipment.The user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving device, Increase the separation between the equipment, Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. Consult your local BSC field service technician for help. Failure of the RF generator could result in an unintended increase of output power. •The use of accessories, transducers and cables other than those specified may result in increased electromagnetic emissions or decreased electromagnetic immunity of the Maestro 3000 Cardiac Ablation System.” • Components of the Maestro 3000 Cardiac Ablation System should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the Maestro 3000 Cardiac Ablation System should be observed to verify normal operation in the configuration in which it will be used. • Failure of the Maestro 3000 Cardiac Ablation System could result in an unintended increase of output power. Precautions: Review the following precautions before using the System: • Do not attempt to operate the BSC Maestro 3000 Cardiac Ablation System before thoroughly reading this Operator’s Manual. •The “Impedance” Display of the Controller should be continuously monitored during RF power delivery. If a sudden rise in impedance is noted, RF power delivery should be discontinued. • Adequate filtering must be used to allow continuous monitoring of the surface electrocardiogram (ECG) during RF power applications. • Read and follow the disposable Dispersive Indifferent Patch (DIP) Electrode manufacturer’s instructions for use.The use of DIP Electrodes, which meet or exceed ANSI/AAMI HF-18 requirements, is required. BSC recommends the use of Valley Labs DIP Electrodes, BSC model number 354. •The entire area of the DIP Electrode should be reliably attached to the patient’s body. Placement on the patient’s back is recommended. • When using high-power Catheters, it is required that two DIP electrodes be used. • Apparent low power output or higher than typical impedance measurements may be indicative of faulty DIP Electrode application or failure of an electrical lead. Check the application of the DIP Electrode and all electrical connections before continuing or selecting higher power outputs. • Skin-to-skin contact (for example between the arms and body of the patient) should be avoided, for example by insertion of dry gauze. • When physiological monitoring equipment is used on the same patient, any monitoring electrodes should be placed as far as possible from the ablation electrodes. Needle monitoring electrodes are not recommended. Monitoring systems incorporating high frequency current-limiting devices are recommended. •The long-term risks of protracted fluoroscopy have not been established. Careful consideration must therefore be given for the use of the device in prepubescent children. Furthermore, the risk/benefit in asymptomatic patients has not been studied. •The cables connecting the Catheter to the System should be positioned in such a way that contact with the patient or other leads is avoided. •The Controller is capable of delivering significant electrical power. Patient or operator injury can result from improper handling of the Catheter and DIP Electrode, particularly when operating the device. During power delivery, the patient should not be allowed to come in contact with grounded metal surfaces.The use of antistatic sheeting is recommended. •The risk of igniting flammable gases or other materials is inherent in the application of RF power. Precautions must be taken to restrict flammable materials from the ablation site. • Do not immerse the Controller, the Remote or accessories in any liquid. Avoid caustic or abrasive cleaners. • Use of non-flammable agents for cleaning and disinfection is recommended. Flammable agents or solvents used for cleaning and disinfection should be allowed to evaporate before high- frequency surgery. • Regularly inspect re-usable cables and accessories. In particular, cables and accessories should be checked for possible damage to the insulation. • Boston Scientific relies on the physician to determine, assess and communicate to the individual patient all foreseeable risks of the cardiac ablation procedure. •The System is designed to be connected to a single ablation catheter at a time. Do not attempt to connect multiple ablation catheters into the Pod, as this will cause unforeseen risks. • BSC recommends that the Controller and Remote Control units be powered off at the end of each procedure in order to ensure that the self-test is performed before the next procedure. •The power selected should be as low as possible for the intended purpose. •The Pod is not intended to be sterilized and should remain outside of the sterile field. •The Maestro 3000 Cardiac Ablation System needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in Section 7.2. • Portable and mobile RF communications equipment can affect the Maestro 3000 Cardiac Ablation System. It is advised not to use this equipment in proximity to the Maestro 3000 Cardiac Ablation System. • Pins of connectors identified with the ESD warning symbol should not be touched and connections should not be made to these connectors unless ESD precautionary procedures are used. • It is recommended that all staff involved in the assembly and/or installation of the Maestro 3000 Cardiac Ablation System receive an explanation of the ESD warning symbol and training in ESD precautionary procedures. Please refer to Section 6.4 for ESD Procedures Adverse Events: The potential risks or discomforts that may be associated with electrosurgical procedures can vary greatly in frequency and severity, and may necessitate additional medical intervention, including surgery. Carefully review the specific indications, contraindications, warnings, precautions, and adverse events included with each catheter, prior to use of the catheter with the Maestro 3000 Cardiac Ablation System. Maestro 3000 System DFU (90487630_AB_EN) Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician. See the appropriate technical manuals for detailed information regarding instructions for use, indications, contraindications, warnings and precautions, and potential adverse events.
  • 2. Maestro 3000® Cardiac Ablation System: The best of the EPT-1000XP™ Cardiac Ablation System with enhanced clinical utility “View Settings” button parametersProgrammable memory buttons Descriptive diagnostic messages“Avg/Max” value displays The best of the EPT-1000XP System Added clinical utilityExpanded ease-of-use Remote Control Unit • Intuitive user interface with no hidden or embedded menus • Powers a complete portfolio of Blazer® Bidirectional Temperature Ablation Catheters – Blazer Prime® XP Catheter and Blazer Prime® HTD Catheter – Blazer® II Catheter, Blazer® II HTD Catheter, and Blazer® II XP Catheter – Chilli II® Cooled Ablation Catheter • Any catheter that currently works with the EPT-1000XP System will also work with the Maestro 3000 System • Up to 100W RF energy for versatility and expanded performance • Optional remote control unit can be placed up to 75 feet from the master unit, which may allow for operation outside radiation exposure • 5 programmable memory buttons let you save frequently used ablation parameters and easily return to starting parameters • Descriptive diagnostic messages aid in troubleshooting • Real-time impedance monitoring – Provides an indicator of tissue type (endocardial vs venous) and tissue/tip contact to enhance catheter positioning • New “Noise Reduction” technology – Low pass filters designed to reduce electronic interference and provide clear electrograms – Optional remote control unit eliminates complex cabling to help reduce noise • “Avg/Max” value displays for temperature, impedance and time provide valuable lesion formation feedback • “View Settings” button lets you see set points during RF delivery