Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
1. JU-040
JU-020
JU-040
JU-020
J J JU-010
U-010 JS-010
S-010
2 LEAF 12MM THK. FRAMELESS DOUBLE
SWING TEMPERED GLASS DOOR (D1)
12MM THK. FRAMELESS
TEMPERED GLASS WALL (GW)
TILED FINISHED FLOOR LINE
FLOOR SLAB
2500MM
1500MM
(VERIFY)
4000MM
(VERIFY
ACTUAL)
REVISIONS:
DESIGN BY:
CADD BY:
CHECKED BY:
APPROVED BY:
DATE:
OWNER:
LOCATION:
NOTE:
Republic Act 545
This drawing as an instrument of
service is a property of registered
Architect and as such must not be
reproduced or copied in part or in
whole without his permission. All
drawing are to be returned when no
longer in use.
LIC. NO.:
TIN. NO.:
DATE:
PLACE ISSUED:
PTR. NO.:
ARCHITECT / CIVIL ENGINEER
LIC. NO.:
TIN. NO.:
DATE:
PLACE ISSUED:
PTR. NO.:
OFFICE IMPROVEMENT ALVEO FINANCIAL TOWER
31ST FLOOR - UNIT 3102
6794 AYALA AVENUE, COR. SALCEDO, MAKATI CENTRAL BUSINESS CENTER, MAKATI CITY
SHEET CONTENTS: SHEET NO.:
AS SHOWN
A
2
PROJECT:
MR. ICHIRO CHUJO
A
JU-040
JU-010
JU-020
2
LEAF
12MM
THK.
FRAMELESS
DOUBLE
SWING
TEMPERED
GLASS
DOOR
PLAN
FINISHED
CEILING
LINE
FFL
SCALE
FRONT ELEVATION
1:50MTS
A-2
6
DOOR AND GLASS WALL SCHEDULE
TAG TYPE
DESCRIPTION
PARTS SPECIFICATION
D1 FRAMELESS 2
LEAF DOUBLE SWING
LEAF 12MM THK. TEMPERED GLASS
HANDLE ROUND STAINLESS 25MMØ
LOCK STAINLESS KEY OPERATED DROP BOLT (SEE MANUFACTURERS DESCRIPTION FOR JU-010)
HINGE STAINLESS FRAMELESS HINGES BOLT TYPE (SEE MANUFACTURERS DESCRIPTION FOR JU-040, JU-020 AND JU-010)
GW FIXED WALL GLASS 12MM THK. TEMPERED GLASS
JU-040
JU-020
GW
D1
A
EXTERIOR
INTERIOR
TIGHTENING
SCREW
JU -040 / JU-020
A
JU-010
FLOOR SLAB
TILE FINISHED
FLOOR LINE
D1
GW
TIGHTENING
SCREW
EMBEDDED
IN
FLOOR
SLAB
FLOOR
SLAB
EXTERIOR
INTERIOR
JU -010
DW
DW
SCALE
GLASS DOOR HINGES DETAILS
NTS
A-2
5
A
C
D
E
SCALE
FLOOR DETAILS SYNTHETIC GRANITE TILES
WITH WATERPROOFING (FT2)
NTS
A-2
2
A - 60X60CM SYNTHETIC GRANITE MATT TILES
B - GROUT FILLINGS
C - LATEX-PORTLAND CEMENT / MORTAR BOND COAT
D - WATERPROOFING / ANTI-FRACTURE MEMBRAINE
E - CONCRETE OR CURED MORTAR BED
B
FLOOR ISOMETRIC DETAIL
NTS
FLOOR SECTION THRU A
NTS
A
A
B
C
SCALE
FLOOR DETAILS CARPET TILES (FT1)
NTS
A-2
3
A - 50X50 CM CARPET TILES
B - LATEX-PORTLAND CEMENT / MORTAR BOND
COAT
C - CONCRETE OR CURED MORTAR BED
FLOOR ISOMETRIC DETAIL
NTS
FLOOR SECTION THRU A
NTS
A
DRY WALL DETAILS (DW)
SCALE
A-2
4
DETAIL A
NTS
7810MM
7102MM
7335MM
2255MM
16692MM
SCALE
REFLECTED CEILING PLAN
A-2
2
RR DE GUZMAN CONST. & DEV'T CORP.
BLK 8 LOT 2 PRISTINA COMMERCIAL,
BUHAY NA TUBIG, IMUS, CAVITE
TEL. NO.: (046) 683-0916 / EMAIL:
rrgconstruct@yahoo.com
7810MM
7102MM
7335MM
2255MM
16692MM
12MM THK. FRAMELESS
TEMPERED GLASS WALL (GW)
2 LEAF 12MM THK. FRAMELESS
DOUBLE SWING TYPE TEMPERED
GLASS DOOR (D1)
50X50CM CARPET TILES
(FT1)
PANTRY SINK LOCATION
DRY WALL (DW)
SCALE
UNIT 3102 FLOOR PLAN
1:100MTRS
A-2
1
60x60CM SYNTHETIC GRANITE
WITH WATERPROOFING
(FT2)
1:100MTRS
MR. RYAN VINCENT R. JARABEJO
ARCHITECT
NTS