This document provides the technical specifications for a digital multimeter and LCR meter Model 306, including its measurement ranges, resolutions, accuracies, and features. It measures DC and AC voltage and current, capacitance, inductance, resistance, duty cycle, frequency, diode test, and transistor hFE. Key features include a 31⁄2 digit LCD display, auto-ranging frequency measurement up to 15MHz, MAX HOLD, and protection from overloads. It is powered by a single 9V battery and has dimensions of 200mm x 90mm x 40mm.
This document provides the technical specifications for a 3 1/2 digit digital multimeter model 603, including its measurement ranges, resolutions, accuracies, and features. The multimeter measures DC and AC voltage, AC and DC current, resistance, has features like diode and continuity testing, and is powered by a single 9V battery. It provides measurements across various voltage, current and resistance ranges with ± accuracies ranging from 0.5% to 5% depending on the measurement type and range.
This document summarizes models of synaptic transmission, including:
- Models of the NMDA receptor and its voltage-dependent magnesium block.
- Models showing activity-dependent recovery from depression at synapses increases their range of effective information transmission frequencies.
- Models examining how short-term synaptic dynamics like depression, facilitation, and activity-dependent recovery affect information transmission and processing at the network level.
This document provides specifications for a digital multimeter (DMM), including its measurement ranges, accuracy, resolution, and other technical details. It lists voltage, current, resistance, and frequency measurement capabilities from millivolts to megavolts, microamps to amps, ohms to megohms, and hertz to megahertz. Accuracy ranges from ppm to percentages of reading depending on the measurement range and integration time. The DMM also has features like guarding, calibration modes, and power output capabilities.
The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications.
This document provides specifications for the JS-K1 series power relay. The relay has 1 pole and 8A medium load control. It features a plastic sealed enclosure, various contact material options, and RoHS compliance. The document includes details on part numbering, specifications, coil ratings, safety standards, characteristic data, dimensions, and RoHS/lead free information. It provides concise technical specifications for the relay in a comprehensive product document.
PC board relays, with a very high dielectric strength of 5000V are the product of user’s choice. Designed in SPDT, DPDT, SPST-NO & DPST-NO the series for direct PC board, Socket and panel socket mounting.
DIGITAL MULTIMETER DT4281/DT4282
Speedy Performance of Professional Testing
Large, easy-to-see display
Optimized for inverter system measurements
Ideal for checking ripple voltage in DC supply systems
Enhance UPS maintenance efficiency
Includes μA DC range for burner system inspection
Data Communications function
https://www.n-denkei.com/singapore/inquiry/
This document provides the technical specifications for a 3 1/2 digit digital multimeter model 603, including its measurement ranges, resolutions, accuracies, and features. The multimeter measures DC and AC voltage, AC and DC current, resistance, has features like diode and continuity testing, and is powered by a single 9V battery. It provides measurements across various voltage, current and resistance ranges with ± accuracies ranging from 0.5% to 5% depending on the measurement type and range.
This document summarizes models of synaptic transmission, including:
- Models of the NMDA receptor and its voltage-dependent magnesium block.
- Models showing activity-dependent recovery from depression at synapses increases their range of effective information transmission frequencies.
- Models examining how short-term synaptic dynamics like depression, facilitation, and activity-dependent recovery affect information transmission and processing at the network level.
This document provides specifications for a digital multimeter (DMM), including its measurement ranges, accuracy, resolution, and other technical details. It lists voltage, current, resistance, and frequency measurement capabilities from millivolts to megavolts, microamps to amps, ohms to megohms, and hertz to megahertz. Accuracy ranges from ppm to percentages of reading depending on the measurement range and integration time. The DMM also has features like guarding, calibration modes, and power output capabilities.
The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications.
This document provides specifications for the JS-K1 series power relay. The relay has 1 pole and 8A medium load control. It features a plastic sealed enclosure, various contact material options, and RoHS compliance. The document includes details on part numbering, specifications, coil ratings, safety standards, characteristic data, dimensions, and RoHS/lead free information. It provides concise technical specifications for the relay in a comprehensive product document.
PC board relays, with a very high dielectric strength of 5000V are the product of user’s choice. Designed in SPDT, DPDT, SPST-NO & DPST-NO the series for direct PC board, Socket and panel socket mounting.
DIGITAL MULTIMETER DT4281/DT4282
Speedy Performance of Professional Testing
Large, easy-to-see display
Optimized for inverter system measurements
Ideal for checking ripple voltage in DC supply systems
Enhance UPS maintenance efficiency
Includes μA DC range for burner system inspection
Data Communications function
https://www.n-denkei.com/singapore/inquiry/
The document provides specifications for the TCRT1000 and TCRT1010 reflective optical sensors. The sensors include an infrared emitter and phototransistor in a leaded package, and are designed to detect the presence or absence of objects within 1 mm of the sensor surface. Key specifications include a peak operating distance of 1 mm, typical output current of 0.5 mA, and operating range of 0.2-4 mm for relative collector current above 20%. Applications include optoelectronic scanning and switching devices.
The 9710 Current Pulse Generator is a digital delay current generator with 2 or 4 independent output channels. It can generate precise current pulses up to 25 amps with timing resolution of 200 ns and pulse widths adjustable from 0.1 to 100 ms. Each channel's delay and pulsewidth can be independently controlled via an easy-to-use interface. It also provides a TTL sync output and safety interlocks.
Dynamic Recrystallization of a Nb bearing Al-Si TRIP steelPello Uranga
This document studies the dynamic recrystallization behavior of a TRIP steel microalloyed with niobium and aluminum when subjected to hot compression tests. It was found that aluminum addition decreases grain boundary energy and increases the driving force for boundary migration, accelerating dynamic recrystallization. Peak strain was related to the Zener-Hollomon parameter and initial grain size. Dynamically recrystallized grain size decreased with increasing strain rate. The kinetics of dynamic recrystallization were characterized for the TRIP steel and compared to other microalloyed steels.
This document provides information about a high frequency crossover device called the XOB1208F200S-T. It is a surface mount component made of high purity alumina and copper microstrip transmission lines. It has a bandwidth exceeding 20 GHz and is suitable for applications beyond 5 GHz like optical modules. It has tight impedance control of 50 ohms and provides signal integrity for routing transitions on single layer boards. Custom prototypes and full production capacity are available.
The Videomic Pro M3 is a compact shotgun condenser microphone that provides broadcast recording quality. It has a super-cardioid polar pattern, integrated shock mounting and foam windscreen, and can be mounted to cameras. It is powered by a 9V battery with over 70 hours of use and has a 3.5mm mini-jack output.
SPICE MODEL of SSM3K15FU (Professional+BDP Model) in SPICE PARKTsuyoshi Horigome
The document provides a device modeling report for a TOSHIBA Power MOSFET with part number SSM3K15FU. The 3-sentence summary is:
The report includes PSpice models and simulation results characterizing the electrical parameters and performance of the MOSFET, such as its transconductance, threshold voltage, on-resistance, switching times, and forward/reverse current characteristics. Comparisons between measured data and simulated values show good agreement within a few percent error. Component specifications and simulation circuits are provided to model and evaluate the MOSFET's electrical behavior.
May 26-31, 2011 INS Conference Presentationstimwave
The document summarizes research on the effects of electrical stimulation of the neuroinsular complex on blood flow in obese and RTX-treated rats. In obese rats, stimulation at 5 Hz increased blood flow, while 100 Hz stimulation decreased it. In RTX-treated rats, pre-stimulation blood flow was higher than post-stimulation at both 5 Hz and 100 Hz. Histological analysis found differences in islet cell morphology between control and obese/RTX groups.
This document discusses simulating a loudness control in LTspice using .wav audio files. It begins with background on equal-loudness contours and how loudness controls can restore low and high frequencies at lower listening levels. The document shows how the frequency response of a simulated loudness control matches equal-loudness contours. It compares the response of a loudness control circuit to a flat volume control and demonstrates using .wav files as inputs and outputs of the LTspice simulation.
This document provides specifications for three digital lux meters - the KM-LUX-99, KM-LUX-100K, and KM-LUX-200K. The lux meters measure light levels and have features like data hold, auto zero adjustment, and a backlit LCD display. They vary in measurement ranges from 0-2,000 lux up to 0-200,000 lux and have measurement resolutions of 1 lux or 0.1 lux. The document also lists electrical specifications, dimensions, weight, and adequate light level guidelines for different locations.
This document provides specifications for the ROTAPULS C82 incremental encoder. It can be used for elevator motors with a resolution up to 4096 pulses per revolution. It has an operating temperature range of -20°C to +70°C as standard, or -40°C to +100°C as an option. The encoder has mechanical specifications including shaft dimensions and speeds, electrical specifications for power supply, output signals, and connections.
This document provides information on explosive atmosphere products certified for use in dust zones, including:
- Proximity sensors for zones 21-22 certified for dust explosions.
- Limit switches, pressure switches, and operator interface products like pushbuttons certified for zones 21-22.
- Weighing, automation, and interface modules from Schneider Electric for integration into zone-rated control panels.
SOLDAMATIC EDUCATIONAL AUGMENTED REALITY Data sheet engSEABERY
This document provides specifications for the Seabery Soluciones welding trainer simulator. The simulator supports SMAW, GMAW, FCAW and GTAW welding processes and various joint configurations. It allows for selection of voltage, amperage, polarity, shielding gas, wire speed and more. The unit includes augmented reality welding masks and comes with standard accessories. Key features include diagnostic evaluation modes, on-screen help for students, and remote maintenance capabilities.
This document summarizes the Multimag TM multi-jet turbine water meter for commercial and industrial applications. The meter is available in sizes from DN 25 to DN 50 mm and complies with various industry standards. It uses direct magnetic transmission without gears in the water for durability and has a large roller display for easy reading. Installation instructions are also provided.
This 650 TV line security camera has high resolution and sensitivity for low light conditions. It uses a 1/3-type CCD image sensor and digital signal processor to achieve 650 horizontal TV lines of resolution with low minimum illumination of 0.15lx for color and 0.01lx for black and white. It has features like day/night mode, noise reduction, backlight compensation, and automatic tone reproduction for improved image quality. It is designed for compact size and low power consumption of 1.6W.
Study of Metadynamic Recrystallization Phenomena in Coarse Grained Nb Microal...Pello Uranga
This study examines metadynamic recrystallization in coarse-grained Nb microalloyed austenite steel. There is a transition between static and metadynamic recrystallization between the critical strain εc and transition strain εT = 2.2εc. Below εc only static recrystallization occurs. Between εc and εT both static and metadynamic recrystallization contribute to softening. Above εT only metadynamic recrystallization occurs. A new model was developed that considers the contributions of both static and metadynamic recrystallization between εc and εT. The model predictions matched experimental validations
This document provides specifications for 1N4001 through 1N4007 plastic silicon rectifier diodes. The diodes have voltage ratings from 50 to 1000 volts, current ratings up to 1 amp, and are packaged in a molded plastic DO-41 case. Key ratings and characteristics include maximum reverse voltage, forward voltage drop, surge current capability, and operating temperature range from -55 to +150 degrees Celsius. Curves show typical forward and reverse diode characteristics.
This experiment studied the principles of X-ray ionization, diffraction, and emission. It found that ionization current levels off at around 100V bias voltage and depends on emission current. X-ray diffraction peaks were observed from NaCl and LiF crystals using Bragg's law, and the optimum operating voltage of the Geiger-Müller tube was around 360V with saturation above 6.1μA emission current.
This creative portfolio highlights the logo design, business card, pullup banner, invite design, Christmas card design, car branding, and Bible marker work of Mkhululi Ncube. The portfolio showcases Ncube's design skills across various projects including logos, marketing materials, seasonal designs, and religious items. Overall, the portfolio provides an overview of Ncube's graphic design work in different areas.
The document provides specifications for the TCRT1000 and TCRT1010 reflective optical sensors. The sensors include an infrared emitter and phototransistor in a leaded package, and are designed to detect the presence or absence of objects within 1 mm of the sensor surface. Key specifications include a peak operating distance of 1 mm, typical output current of 0.5 mA, and operating range of 0.2-4 mm for relative collector current above 20%. Applications include optoelectronic scanning and switching devices.
The 9710 Current Pulse Generator is a digital delay current generator with 2 or 4 independent output channels. It can generate precise current pulses up to 25 amps with timing resolution of 200 ns and pulse widths adjustable from 0.1 to 100 ms. Each channel's delay and pulsewidth can be independently controlled via an easy-to-use interface. It also provides a TTL sync output and safety interlocks.
Dynamic Recrystallization of a Nb bearing Al-Si TRIP steelPello Uranga
This document studies the dynamic recrystallization behavior of a TRIP steel microalloyed with niobium and aluminum when subjected to hot compression tests. It was found that aluminum addition decreases grain boundary energy and increases the driving force for boundary migration, accelerating dynamic recrystallization. Peak strain was related to the Zener-Hollomon parameter and initial grain size. Dynamically recrystallized grain size decreased with increasing strain rate. The kinetics of dynamic recrystallization were characterized for the TRIP steel and compared to other microalloyed steels.
This document provides information about a high frequency crossover device called the XOB1208F200S-T. It is a surface mount component made of high purity alumina and copper microstrip transmission lines. It has a bandwidth exceeding 20 GHz and is suitable for applications beyond 5 GHz like optical modules. It has tight impedance control of 50 ohms and provides signal integrity for routing transitions on single layer boards. Custom prototypes and full production capacity are available.
The Videomic Pro M3 is a compact shotgun condenser microphone that provides broadcast recording quality. It has a super-cardioid polar pattern, integrated shock mounting and foam windscreen, and can be mounted to cameras. It is powered by a 9V battery with over 70 hours of use and has a 3.5mm mini-jack output.
SPICE MODEL of SSM3K15FU (Professional+BDP Model) in SPICE PARKTsuyoshi Horigome
The document provides a device modeling report for a TOSHIBA Power MOSFET with part number SSM3K15FU. The 3-sentence summary is:
The report includes PSpice models and simulation results characterizing the electrical parameters and performance of the MOSFET, such as its transconductance, threshold voltage, on-resistance, switching times, and forward/reverse current characteristics. Comparisons between measured data and simulated values show good agreement within a few percent error. Component specifications and simulation circuits are provided to model and evaluate the MOSFET's electrical behavior.
May 26-31, 2011 INS Conference Presentationstimwave
The document summarizes research on the effects of electrical stimulation of the neuroinsular complex on blood flow in obese and RTX-treated rats. In obese rats, stimulation at 5 Hz increased blood flow, while 100 Hz stimulation decreased it. In RTX-treated rats, pre-stimulation blood flow was higher than post-stimulation at both 5 Hz and 100 Hz. Histological analysis found differences in islet cell morphology between control and obese/RTX groups.
This document discusses simulating a loudness control in LTspice using .wav audio files. It begins with background on equal-loudness contours and how loudness controls can restore low and high frequencies at lower listening levels. The document shows how the frequency response of a simulated loudness control matches equal-loudness contours. It compares the response of a loudness control circuit to a flat volume control and demonstrates using .wav files as inputs and outputs of the LTspice simulation.
This document provides specifications for three digital lux meters - the KM-LUX-99, KM-LUX-100K, and KM-LUX-200K. The lux meters measure light levels and have features like data hold, auto zero adjustment, and a backlit LCD display. They vary in measurement ranges from 0-2,000 lux up to 0-200,000 lux and have measurement resolutions of 1 lux or 0.1 lux. The document also lists electrical specifications, dimensions, weight, and adequate light level guidelines for different locations.
This document provides specifications for the ROTAPULS C82 incremental encoder. It can be used for elevator motors with a resolution up to 4096 pulses per revolution. It has an operating temperature range of -20°C to +70°C as standard, or -40°C to +100°C as an option. The encoder has mechanical specifications including shaft dimensions and speeds, electrical specifications for power supply, output signals, and connections.
This document provides information on explosive atmosphere products certified for use in dust zones, including:
- Proximity sensors for zones 21-22 certified for dust explosions.
- Limit switches, pressure switches, and operator interface products like pushbuttons certified for zones 21-22.
- Weighing, automation, and interface modules from Schneider Electric for integration into zone-rated control panels.
SOLDAMATIC EDUCATIONAL AUGMENTED REALITY Data sheet engSEABERY
This document provides specifications for the Seabery Soluciones welding trainer simulator. The simulator supports SMAW, GMAW, FCAW and GTAW welding processes and various joint configurations. It allows for selection of voltage, amperage, polarity, shielding gas, wire speed and more. The unit includes augmented reality welding masks and comes with standard accessories. Key features include diagnostic evaluation modes, on-screen help for students, and remote maintenance capabilities.
This document summarizes the Multimag TM multi-jet turbine water meter for commercial and industrial applications. The meter is available in sizes from DN 25 to DN 50 mm and complies with various industry standards. It uses direct magnetic transmission without gears in the water for durability and has a large roller display for easy reading. Installation instructions are also provided.
This 650 TV line security camera has high resolution and sensitivity for low light conditions. It uses a 1/3-type CCD image sensor and digital signal processor to achieve 650 horizontal TV lines of resolution with low minimum illumination of 0.15lx for color and 0.01lx for black and white. It has features like day/night mode, noise reduction, backlight compensation, and automatic tone reproduction for improved image quality. It is designed for compact size and low power consumption of 1.6W.
Study of Metadynamic Recrystallization Phenomena in Coarse Grained Nb Microal...Pello Uranga
This study examines metadynamic recrystallization in coarse-grained Nb microalloyed austenite steel. There is a transition between static and metadynamic recrystallization between the critical strain εc and transition strain εT = 2.2εc. Below εc only static recrystallization occurs. Between εc and εT both static and metadynamic recrystallization contribute to softening. Above εT only metadynamic recrystallization occurs. A new model was developed that considers the contributions of both static and metadynamic recrystallization between εc and εT. The model predictions matched experimental validations
This document provides specifications for 1N4001 through 1N4007 plastic silicon rectifier diodes. The diodes have voltage ratings from 50 to 1000 volts, current ratings up to 1 amp, and are packaged in a molded plastic DO-41 case. Key ratings and characteristics include maximum reverse voltage, forward voltage drop, surge current capability, and operating temperature range from -55 to +150 degrees Celsius. Curves show typical forward and reverse diode characteristics.
This experiment studied the principles of X-ray ionization, diffraction, and emission. It found that ionization current levels off at around 100V bias voltage and depends on emission current. X-ray diffraction peaks were observed from NaCl and LiF crystals using Bragg's law, and the optimum operating voltage of the Geiger-Müller tube was around 360V with saturation above 6.1μA emission current.
This creative portfolio highlights the logo design, business card, pullup banner, invite design, Christmas card design, car branding, and Bible marker work of Mkhululi Ncube. The portfolio showcases Ncube's design skills across various projects including logos, marketing materials, seasonal designs, and religious items. Overall, the portfolio provides an overview of Ncube's graphic design work in different areas.
This document provides background information on public procurement in Ghana. It discusses how the government has implemented various laws and policies over time to reform procurement practices, address issues of corruption and inefficiency, and promote transparency and value for money. The key reforms included the Public Procurement Act of 2003, which established standardized procedures and oversight mechanisms. However, some public entities still do not fully comply with the Act's provisions. The study aims to examine the impact of the 2003 Act on procurement practices and value for money in the Ga Central Municipal Assembly.
Capitalizing on OTT Breakfast Forum-Olivier Carmona, AwoXVerimatrix
The document discusses strategies for delivering over-the-top (OTT) television experiences beyond traditional set-top boxes and managed IPTV networks. It describes companies using OTT apps on connected TVs and partnering with TV manufacturers to reach new customers outside of traditional networks. It also discusses using standards like DLNA to distribute premium content across devices and the role of companies like AwoX in providing middleware and solutions to enable these connected TV experiences.
This document summarizes the author's experiences from a summer internship working on the television program "Daytime." The author learned that personalities and strong communication skills are essential for success in media careers. They observed skills like camerawork, editing, and dealing with unexpected challenges during live broadcasts. The internship highlighted both the creative and business aspects of television production, and how companies must consider their audiences and clients. The author gained valuable practical experience and advice that will help in pursuing a career in communications.
Rapor semester gasal dan genap menilai siswa dalam aspek kognitif, psikomotorik, dan afektif. Pada semester gasal, siswa memahami konsep sel, jaringan, dan sistem organ serta penyakitnya. Mereka meningkatkan keterampilan mengamati sel dan jaringan dengan mikroskop. Siswa mengamalkan perilaku agama dan sosial selama pembelajaran. Pada semester genap, siswa memahami kerja sistem organ tubuh dan penyakit
Este documento apresenta um curso online de Direito Constitucional ministrado pelo professor Vítor Cruz. O curso aborda o Direito Constitucional por meio das cinco fontes principais: Constituição, Doutrina, Jurisprudência, Macetes e Questões. Serão apresentadas 14 aulas regulares e 8 módulos extras cobrindo os principais temas da disciplina. O objetivo é estudar de forma completa para concursos públicos, relacionando teoria e questões.
This document describes the specifications of the KM 2775 33⁄4 digit 2000A AC/DC digital clamp meter. It has 11 functions and 34 measurement ranges. Key features include auto-ranging, data hold, continuity and diode testing. Electrical specifications include the measurement ranges and accuracy for AC/DC voltage and current, capacitance, frequency, resistance, continuity testing and diode testing. It is powered by a standard 9V battery and has safety certifications for CAT III 600V applications.
This document provides specifications for the 2781/2781-T multimeter, including its measurement ranges and accuracy for DC and AC current, voltage, resistance, capacitance, frequency, diode testing, and temperature (for the 2781-T model only). It has a jaw opening of 40mm, 33⁄4 digit LCD display, overload protection on all ranges, data hold, low battery indication, and auto power off. Accessories include test leads, carrying case, manual, and battery. The meter is manufactured by Kusam-Meco Import Export.
This document describes the features and specifications of the Model 2700 digital clamp meter. It has a large LCD display for easy reading, a data hold switch, low battery indication, continuity buzzer, tough ABS plastic housing, diode check function, and includes test leads, carrying case, and manual. It measures AC and DC current and voltage, resistance, tests diodes, and has continuity testing with overload protection on all ranges.
This document provides specifications for APLab's Digital Multimeter Model 1003. It can measure AC/DC voltage, AC/DC current, resistance, continuity, diode test, and dB. It has a 31⁄2 digit LED display, measures up to 1000V and 1A, and has accuracy of 0.1% for DC voltage and 0.5% for AC voltage. The device is portable with a table top design, has overload protection, and comes with test leads and a 600 ohm termination for dB measurements.
This document summarizes the specifications of a function generator that can output various function waves from 0.2Hz to 2MHz. It has adjustable frequency, amplitude, and duty cycle ranges. The generator displays frequency and amplitude and outputs sine, square, triangle, rectangle, and sawtooth waves with distortions and errors within specifications. It measures 270x215x100mm and weighs approximately 1.6kg, operating from 220V or 110V power sources.
Hioki BATTERY TESTER BT3554-50
BATTERY HiTESTER BT3561A
BATTERY HiTESTER BT3562A
Fully automated production line testing of large packs for xEVs or large packs of up to 300 V
The 709H HART Loop Calibrator can source and measure DC current and voltage, as well as simulate and communicate with HART devices. It has a range of 0-22mA for current sourcing and simulation, and -2-28V and -4-33mA for voltage and current measuring. It can power HART loops up to 24V and 22mA, and supports HART communication functions including reading device info and calibration. The 709H also has features like adjustable backlight, automatic ramping and stepping functions, and a 3.2 inch color display. It is powered by batteries or an adapter and has protection rating of IP65.
The DM-87 is a 41⁄2 digital multimeter that features various measurement functions including voltage, current, resistance, capacitance, frequency, temperature, and special functions like VSD testing and transistor testing. It has a large LCD display, data hold, max/min value hold, and auto power-off capabilities. Measurement ranges and basic accuracies are provided for each function. Standard accessories include test leads, battery, manual, temperature probe, and crocodile clip.
The document compares the specifications of two pulse generators: the SRS DG 535 and the QC 9520. It shows that the QC 9520 has more features and flexibility across most categories, including communications interfaces, trigger/gate options, delay ranges and resolutions, internal rate generator performance, and I/O options. The QC 9520 also has modular options that allow for additional capabilities like incremental output, high voltage pulses, and dual optical/trigger inputs that are not available on the SRS DG 535. In summary, the QC 9520 generally outperforms the SRS DG 535 according to the specifications comparison chart.
This document summarizes the features and specifications of the DM-56 digital multimeter. It can measure DC and AC voltage up to 1000V, DC and AC current up to 20A, resistance up to 200MΩ, capacitance up to 200uF, frequency up to 200kHz, and includes additional functions like diode and transistor testing. It has a large LCD display, 20,000 count resolution, backlight, data hold, and auto power off. Measurements are taken 3 times per second with an accuracy of 0.05% for DC voltage and 1.5% for AC current. It is powered by a 9V battery and includes test leads, holster, and manual.
The GMX Series is Alpha's line interactive standby power supply designed for cable television and broadband systems. It provides regulated AC power free of spikes, surges, sags and noise, and can compensate for ±30% input voltage variations. Key features include optional DOCSIS or ethernet monitoring, a smart display, programmable battery testing, and replaceable surge protectors. It is available in 120V, 240V, and 240V 50Hz models ranging from 7.8 to 60 pounds.
ultra slim relays embody the latest in compact relay design technology you can find anywhere in the world market. Only a few of the world`s top players are able to produce this kind of high performance fully sealed type of relays.
This document summarizes the specifications of a V/mA calibrator with an accuracy of ±0.05% 04. It has input ranges for voltage from 10V to 11V and current from 0mA to 22mA. It can source up to 10mA of current and has a resolution of 1mV for voltage and 0.001mA for current. Additional features include a 24V loop power supply, battery or AC power operation, and safety compliance with IEC 1010 standards.
The document summarizes the features and specifications of the AD620 instrumentation amplifier. Key points include:
- The AD620 requires only one external resistor to set gains from 1 to 10,000. It has low power consumption of 1.3mA max and works from ±2.3V to ±18V supplies.
- It has excellent DC performance with 50uV max offset voltage, 0.6uV/°C max drift, and 1.0nA max bias current. Common mode rejection is 100dB min. Noise is also low at 9nV/√Hz input voltage noise.
- Applications include weigh scales, ECG and medical devices, transducers, data acquisition,
The document discusses three digital lux meter models - KM-LUX-99, KM-LUX-100K, and KM-LUX-200K. The meters precisely measure light levels across various ranges in lux or footcandles. They have features like LCD displays, low battery indicators, light sensors, and data hold. The meters are compact, accurate, and durable. Recommended light levels for different tasks are also provided in footcandles or lux.
This document provides specifications for the KUSAM-MECO portable energy audit kit. The kit measures electrical parameters such as voltage, current, power, energy and power factor. It can be used for 1 or 3 phase systems and has programmable current transformer and potential transformer ratios. Key features include 12 LED displays, 4 function keys, RS485 communication, and included current clamp sensors. The company that produces the kit is KUSAM ELECTRICAL INDUSTRIES LTD based in Mumbai, India.
This document provides specifications for an LNB satellite product from Norsat International. The LNB has a noise temperature of 20-25K, LO stability of ±5-25 kHz, gain of 62dB, and operates in the C-band frequency range of 3.625-4.2 GHz. It requires a power input of +12 to +24V and has physical dimensions of 180x100x70mm.
This document provides specifications for an intelligent satellite solution called the LNB 1000HE from Norsat International. It has typical specifications including a noise figure of 0.8 dB, conversion gain of 55 dB, and LO stability of ±25 kHz over temperature (excluding offset) and ±10 kHz. It operates in the KU-band frequency range of 10.95-12.75 GHz with an output frequency range of 950-2750 MHz. Ordering involves specifying parameters like connector type, frequency band, noise figure and LO stability.
WERNER`s 20 Series General Purpose & Power Relays represent the most complete line of state-of-the-art high
performance electrical Relays, designed and manufactured to highest international industry standards.
Mechanical lifetimes of up to 10 Million operations and electrical durability of up to 250.000 switching cycles under
full load make WERNER Relays your best choice of all.
katalog agilent-digital-multimeter-34401 a-tridinamika, jual agilent digital multimeter 3458 a, beli, info, harga, spesifikasi dan review
dapatkan informasi lengkap tentang produk agilent di www.tridinamika.com
untuk informasi dan pemesanan hubungi sales@tridinamika.com
1. TECHNICAL SPECIFICATIONS:
Accuracy : ± (% reading + digit) one year warranty.
DC VOLTAGE AC VOLTAGE (50Hz~500Hz)
3½ DIGIT 1999 COUNTS Range Resolution Accuracy Range Resolution Accuracy
200 mV 100 mV 200 mV 100 mV
DIGITAL MULTIMETER + 2 V 1 mV 2 V 1 mV
±(1.0% rdg + 4 dgts)
LCR METER 20 V 10 mV ±(0.5% rdg + 1 dgt) 20 V 10 mV
200 V 100 mV 200 V 100 mV
MODEL - 306
1000 V 1 V 1000 V 1 V ±(2.0% rdg + 4 dgts)
Input Impedance : 10MW Input Impedance : 10MW
Overload Protection : 500V DC or AC rms Overload Protection : 500V DC or AC rms
on 200mV range, 1000V DC or 750V AC rms on 200mV range, 1000V DC or 750V AC rms
on all other ranges on all other range
DC CURRENT AC CURRENT(50Hz~500Hz)
Range Resolution Accuracy Range Resolution Accuracy
20 mA 10 mA 20 mA 10 mA
±(1.0% rdg + 1 dgt) ±(1.5% rdg + 4 dgts)
200 mA 100 mA 200 mA 100 mA
10 A 10 mA ±(3.0% rdg + 1 dgt) 10 A 10 mA ±(3.5% rdg + 4 dgts)
Input Protection : 0.5A/250V fast blow Input Protection : 0.5A/250V fast blow
fuse 10A/600V fast blow ceramic fuse fuse 10A/600V fast blow ceramic fuse
CAPACITANCE INDUCTANCE
Range Resolution Accuracy Range Resolution Accuracy
2000 pF 0.01 pF 2 mH 1 mH ±(5.0% rdg + 20 dgts)
20 nF 10 pF 20 mH 10 mH
±(5.0% rdg + 10 dgts)
200 nF 100 pF 200 mH 100 mH
2 mF 1 nF ±(5.0% rdg + 10 dgts)
2 H 1 mH
200 mF 100 nF ±(8.0% rdg + 10 dgts)
20 H 10 mH
above 100mf
Test Frequency : 2mH, 20mH ranges 1KHz
Test Frequency : 2nF, 20nF ranges 1KHz 200mH, 2H ranges 270Hz, 20H range 27Hz
200nF, 2mF ranges 270Hz, 200mF range 27Hz Test Conditions : quality factor > 5 in 270Hz
DUTY CYCLE RESISTANCE
Range Accuracy Resolution Range Resolution Accuracy
10.0% - 90.0% ±(1.0% rdg + 10 dgts) 0.1% 200 W 0.1 W ±(0.8% rdg + 4 dgts)
Pulse Width : >10Hz. <20KHz TTL signal 2 KW 1 W
Overload Protection : 500V DC or AC rms 20 KW 10 W
200 KW 100 W ±(0.8% rdg + 2 dgts)
CONTINUITY TEST 2000 KW 1 KW
Audible Sound Buzzer 20 MW 10 KW +(3.0% rdg + 4 dgts)
Less than 40W ± 20W 2000 MW 1 MW ±(5.0% rdg-10 dgts)+ 10 dgts
Overload Protection : 500V DC or AC rms
FEATURES Overload Protection :
Open Circuit Voltage : 0.3V DC (3.0V DC on 200W and
500V DC or AC rms
2000MW ranges)
n Professional Grade Rugged DMM + LCR Meter
n Display : 3½ digit LCD display (1999 Counts) FREQUENCY (AUTO RANGING)
n Digit Size : 18mm(H) Range Resolution Accuracy
n Over range Indication : ‘OL’ or ‘-OL’ is displayed. 2 KHz 1 Hz
n EN61010-1 Approval Protection Class II, Pollution Degree 2. 20 KHz 10 Hz
n Most rugged, Easy use hand held meter. 200 KHz 100 Hz ±(0.1% rdg + 1 dgt)
n MAX HOLD facility 2000 KHz 1 KHz
15 MHz 10 KHz
n Operating Temperature : 0°C to 40°C
Relative Humidity : < 70% non condensing Sensitivity : 1.0V rms min
n Storage Temperature : -20°C to 60°C Overload Protection : 500V DC or AC rms
Relative Humidity : < 80% non condensing Effect Reading : 20-1999
n Power : Single, Standard 9V battery.
DIODE TEST
n Dimension : 200mm(L) x 90mm(W) x 40mm(H)
Test Current Test Voltage Accuracy
n Weight : Approx. 400g.
1.0mA ± 0.6mA 3.0V MAX. ±(3.0% rdg + 3 dgts)
n Ohm, Diode, Continuity and Frequency Input Protection.
Overload Protection : 500V DC or AC rms
n Auto Range on Frequency range and measurement upto 15MHz
n Capacitance, Inductance, Resistance, hFE, Diode test & TRANSISTOR hFE TEST
Audible Continuity Check Function. Range Vce Basic DC Current
n Accessories : Test Leads, Carrying Case, User Manual, Battery. 0 to 1000 <3.0V DC 10 mA approx.
KUSAM-MECO IMPORT EXPORT PVT. LTD.
Office : 17, Bharat Industrial Estate, T.J. Road, Sewree (W), Mumbai-400015. India.
Sales Direct : 24156638 Tel. : (022) 2412 4540, 2418 1649 Fax : (022) 2414 9659
AN ISO 9001:2000 COMPANY
E-mail : kusam_meco@vsnl.net, Website : www.kusamelectrical.com, www.kusam-meco.co.in
C:/SUDHIR/LINE WORK/306/306.CDR
B7