Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
Ashbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation Schedule
MilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestones
M0580 WALSH Complete of Electical Room 4 (EX-Screen) 0 315 08-Dec-16 -3 57 0%
M0670 WALSH Start of Primary Gallery 8 0 361 12-Dec-16 -31 24 0%
A20750 WALSH SUBSTANTIAL COMPLETION 0 -125 24-Apr-18 78 0 0%
New Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen Bldg
GeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneral
BLOW-RM-1095 GOW Ground Floor - Heating Piping 10 220 02-Nov-16 A 25-Nov-16 -44 0 44.44%
MECH-RM-1-1045 LANCASTERInstall Down Run of Ductwork Following Pre-cast Panels 20 -24 22-Nov-16 11-Dec-16 0%
MECH-RM-1-1025 TROY Ground Floor and Pump Room - Install Fire Protection System 20 -47 28-Nov-16 03-Jan-17 0 0%
Screen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump Room
PUMP-RM-1030 QUAN Pump Room - Install Cable trays 5 -15 13-Dec-16 19-Dec-16 -63 43 0%
PUMP-RM-1040 GOW Pump Room - Install Pump Skids 1 -15 20-Dec-16 20-Dec-16 -63 43 0%
PUMP-RM-1050 GOW Pump Room - Complete Tie Ins to Skids 10 -15 21-Dec-16 12-Jan-17 -63 43 0%
Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1
ELEC-RM-1-CX-130 QUAN Elec Rm #1 - Pull Wiring to MCCs in EL #2 11 -147 28-Nov-16 12-Dec-16 12 0 0%
ELEC-RM-1-1070 QUAN Elec Rm #1 - Cable Termination to MCCs in EL#2 11 -147 13-Dec-16 05-Jan-17 21 0 0%
Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1
MECH-RM-1-1070 GOW Install Mech Room #1 - Control Wiring 10 32 24-Oct-16 A 25-Nov-16 -3 0 80%
MECH-RM-1-1000 LANCASTERInstall Mech Room #1 - HVAC Duct Work 11 -15 18-Oct-16 A 28-Nov-16 -64 -13 80%
MECH-RM-1-1030 QUAN Install Mech Room #1 - Cable trays 10 -15 29-Nov-16 12-Dec-16 1 43 0%
Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)
73060 GOW Notice Shop Testing Aeration Blowers 6 271 11-Sep-16 A 18-Nov-16 -76 0 91.3%
73070 GOW Shop Test Aeration Blowers 4 181 21-Nov-16 24-Nov-16 -55 0 0%
BLOW-RM-1020 TOR Blower Room - Fabricate & InstallALP System Structural Supports 13 -80 13-Nov-16 25-Nov-16 13 0%
73090 GOW Deliver Aeration Blowers 1 272 07-Dec-16 07-Dec-16 -37 0 0%
BLOW-RM-1015 GOW Install Blower Room - ALP Piping 26 -80 26-Nov-16 21-Dec-16 -37 0 0%
73075 GOW Install Blower Room - ALP Ductwork 26 250 26-Nov-16 21-Dec-16 0%
21063475 WALSH Complete Rebar for Equipment Pads 2 250 22-Dec-16 23-Dec-16 -1 0%
BLOW-RM-1090 GOW Install Blower Room - Insulation 10 9 22-Dec-16 31-Dec-16 -37 0 0%
BLOW-RM-1030 QUAN Blower Room - Install Cable trays 20 -57 22-Dec-16 27-Jan-17 -27 0 0%
Truck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading Area
TRUCK-LB-1030 GOW Truck Loading Bay - Process Piping 21 -102 11-Oct-16 A 12-Dec-16 16 0 40%
TRUCK-LB-1010 QUAN Truck Loading Bay - Cable trays 20 -111 28-Nov-16 03-Jan-17 -18 24 0%
Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)
ADD-1085 PRECAST Install Precast Wall Panel at Low Roof at Elec. & Mech. Rm. 2 1 -93 07-Nov-16 A 14-Nov-16 -30 -1 66.67%
21063895 PAINT Paint inside face of architectural precast panels 2 23 16-Nov-16 17-Nov-16 0%
ELEC-RM-2-1010 QUAN Elec Rm #2 - Set MCC's 10 -125 17-Oct-16 A 25-Nov-16 -1 -29 60%
ELEC-RM-2-1050 QUAN Elec Rm #2 - Cable Trays 10 -147 08-Nov-16 A 25-Nov-16 24 24 33.33%
ELEC-RM-2-1020 QUAN Elec Rm #2 - Set Transformer 5 16 28-Nov-16 02-Dec-16 -1 -1 0%
21063850 MASON Build Partation Block Wall for Elec. Rm 2 & Mech. Rm 2 5 12 28-Nov-16 02-Dec-16 -44 -5 0%
21063900 TRIUMPH Install Roof Over Electrical/Mechanical Room #2 10 19 22-Nov-16 05-Dec-16 0%
21063890 PAINT Paint Block Wall 2 12 05-Dec-16 06-Dec-16 -7 0%
21063905 GOW Set 2 Condensate Units over Electrical Room #2 1 19 06-Dec-16 06-Dec-16 0%
ELEC-RM-2-1030 QUAN Elec Rm #2 - Install Control Panel 5 16 05-Dec-16 09-Dec-16 -1 -1 0%
J J A S D J A J J A S O J F A J
24-Apr-18, Ashbridges - P
24-Apr-18, Milestones
Complete of Electical Room 4 (EX-Screen)
Start of Primary Gallery 8
SUBSTANTIAL COMPLET
10-Mar-17, New Screen Bldg
03-Jan-17, General
Ground Floor - Heating Piping
Install Down Run of Ductwork Following Pre-cast Panels
Ground Floor and Pump Room - Install Fire Protection S
12-Jan-17, Screen Pump Room
Pump Room - Install Cable trays
Pump Room - Install Pump Skids
Pump Room - Complete Tie Ins to Skids
05-Jan-17, Electrical Room 1
Elec Rm #1 - Pull Wiring to MCCs in EL #2
Elec Rm #1 - Cable Termination to MCCs in EL#2
12-Dec-16, Mechanical Room 1
Install Mech Room #1 - Control Wiring
Install Mech Room #1 - HVAC Duct Work
Install Mech Room #1 - Cable trays
27-Jan-17, Blower Room (Scn Bldg)
Notice Shop Testing Aeration Blowers
Shop Test Aeration Blowers
Blower Room - Fabricate & InstallALP System Structural S
Deliver Aeration Blowers
Install Blower Room - ALP Piping
Install Blower Room - ALP Ductwork
Complete Rebar for Equipment Pads
Install Blower Room - Insulation
Blower Room - Install Cable trays
03-Jan-17, Truck Loading Area
Truck Loading Bay - Process Piping
Truck Loading Bay - Cable trays
09-Dec-16, Electrical Room 2 (Screen 2nd floor)
Install Precast Wall Panel at Low Roof at Elec. & Mech. Rm
Paint inside face of architectural precast panels
Elec Rm #2 - Set MCC's
Elec Rm #2 - Cable Trays
Elec Rm #2 - Set Transformer
Build Partation Block Wall for Elec. Rm 2 & Mech. Rm 2
Install Roof Over Electrical/Mechanical Room #2
Paint Block Wall
Set 2 Condensate Units over Electrical Room #2
Elec Rm #2 - Install Control Panel
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 1 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2
MECH-RM-2-1010 LANCASTERMechanical Room #2 - HVAC Duct Work 4 -23 10-Oct-16 A 17-Nov-16 -10 0 85.71%
MECH-RM-2-1020 GOW Mechanical Room #2 - Drainage Services 5 -23 14-Nov-16 18-Nov-16 -6 0 0%
MECH-RM-2-1030 GOW Mechanical Room #2 - Process Piping 9 -23 01-Dec-16 13-Dec-16 -13 0 0%
MECH-RM-2-1055 INSUL Mechanical Room #2 - Insulation 5 2 14-Dec-16 20-Dec-16 -3 0 0%
MECH-RM-2-1060 GOW Mechanical Room #2 -VFD's to AHU 14 -23 14-Dec-16 11-Jan-17 3 0 0%
Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)
MECH-ROOM-3-1000 GOW Set AHUs and MCC on Equipment Pads 1 -31 14-Nov-16 14-Nov-16 -10 1 0%
15011100 STEEL Install Steel Columns and Girders West of Col. 14 to elev 101.5 Including Metal Deck 10 -31 15-Nov-16 28-Nov-16 -10 -3 0%
15011400 ROOF Install Roof over Metal Decking 5 22 29-Nov-16 05-Dec-16 5 -3 0%
ADD-6040 PRECAST Install Precast Wall Panel at High Roof at Mech. Rm. 3 5 -52 09-Dec-16 15-Dec-16 2 0 0%
ADD-6035 PAINT Paint Mechanical Room 3 9 -52 16-Dec-16 06-Jan-17 6 0 0%
ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16
ARS4200650 STRUCT Grout Stop Log Guides 10 -10 08-Jun-16 A 25-Nov-16 -60 -11 91.15%
15010400 PRECAST Install Precast Concrete Panel Walls "East of Col. 14 to elev. 96.04" 9 -34 15-Nov-16 25-Nov-16 -28 1 0%
ADD-2020 PRECAST Caulking Joints for Precast Wall - East of Col. 14 to Col. 17 2 28 28-Nov-16 29-Nov-16 1 0%
21063520 Scaffold Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproofing 8 -103 21-Nov-16 30-Nov-16 -37 -8 0%
ARS4200655 STRUCT Complete Concrete Topping on hollow Core Deck - Col. 14 to 17 5 71 26-Nov-16 30-Nov-16 0%
15006210 GOW Set Sluice Gates & Stop Log Guides 15 -10 20-Jun-16 A 02-Dec-16 -67 -16 81.93%
65080 GOW Install Course Bubble Aeration - Screen Influent 15 -3 14-Nov-16 02-Dec-16 28 -5 0%
44320 TOR PROCURE CATWALK PLATFORMS "Screen & Grit Conveyor Area" 20 -218 02-Aug-16 A 02-Dec-16 -65 -6 83.74%
15062800 TOR Deliver Catwalk materials 1 -151 05-Dec-16 05-Dec-16 -42 -1 0%
ARS4200635 WALSH Screen Channel No. 5, 3 & 1 Concrete Leak Test 10 -3 05-Dec-16 16-Dec-16 -19 0 0%
ARS800150 WALSH Screen Channel Wall Visual Leak Test (Lower Half) for Screen Installation 10 -3 05-Dec-16 16-Dec-16 -19 0 0%
21063855 ROOF Install Roof Insulation and Roof Membrance 15 10 28-Nov-16 16-Dec-16 -39 1 0%
ARS800160 WALSH Screen Channel Wall Crack Inject (as required) 3 -10 20-Dec-16 22-Dec-16 -30 0 0%
ADD-2010 PRECAST Paint Coat for Precast Decking Lower Roof - East of Col. 14 to Col. 17 5 10 19-Dec-16 03-Jan-17 11 0%
15060522 GOW Install RWL 20 -20 01-Dec-16 06-Jan-17 -37 -8 0%
21062980 TOR Screen Catwalk East of Col. 14 to elev 95.7 20 -151 06-Dec-16 11-Jan-17 0 -1 0%
53260 QUAN Rough In Cable Tray Wall Mounted Under Overhead Crane Col. 14 to 17 30 -18 29-Nov-16 18-Jan-17 -29 0 0%
15061165 LANCASTERInstall HVAC Duct Supply (East) 30 -20 01-Dec-16 20-Jan-17 -27 2 0%
15061173 LANCASTERInstall HVAC Duct Exhaust (East) 30 -20 01-Dec-16 20-Jan-17 -27 2 0%
Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14
21063560 Scaffold Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproofing 5 -107 31-Oct-16 A 18-Nov-16 -44 -8 66.67%
21063065 GOW Install RWL 10 -95 21-Nov-16 02-Dec-16 -29 0 0%
15011300 PRECAST Install Precast Wall Panels "West of col. 14 to elev 101.5" 19 -93 07-Nov-16 A 08-Dec-16 -18 0 20.83%
ADD-2050 PRECAST Caulking Joints for Precast Wall - West of Col. 14 to Col. 10 2 37 09-Dec-16 12-Dec-16 0 0%
21062920 FPROOF Apply Fire Spray for Columns and Girders West of Col. 14 to elev 95.7 10 -103 01-Dec-16 14-Dec-16 -37 -8 0%
ADD-2060 PAINT Paint Coat for Hollow Core Ceiling - West of Col. 14 to Col. 10 5 30 15-Dec-16 21-Dec-16 -8 0%
ADD-2070 PAINT Paint Coat for Precast Walls - West of Col. 14 to Col. 10 5 30 22-Dec-16 06-Jan-17 -7 0%
15011300-1 WALSH Install Pre-finished Perforated Aluminum Cladding Walls "West of col. 14 to elev 101.5" 15 196 09-Dec-16 09-Jan-17 -18 0 0%
15061169 LANCASTERInstall HVAC Duct Supply ( West) 30 -7 21-Nov-16 10-Jan-17 -29 0 0%
15061177 LANCASTERInstall HVAC Duct Exhaust (West) 30 -95 21-Nov-16 10-Jan-17 -29 0 0%
61080 GOW Install Screenings Washer/Compactor 50 -107 07-Dec-16 24-Feb-17 -56 -8 0%
Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14
21063030 TOR Install Grit Handling Area Railings 1 135 06-Dec-16 06-Dec-16 -21 -1 0%
J J A S D J A J J A S O J F A J
11-Jan-17, Mechanical Room 2
Mechanical Room #2 - HVAC Duct Work
Mechanical Room #2 - Drainage Services
Mechanical Room #2 - Process Piping
Mechanical Room #2 - Insulation
Mechanical Room #2 -VFD's to AHU
06-Jan-17, Mechanical Room 3 (Screen Penthouse)
Set AHUs and MCC on Equipment Pads
Install Steel Columns and Girders West of Col. 14 to elev 1
Install Roof over Metal Decking
Install Precast Wall Panel at High Roof at Mech. Rm. 3
Paint Mechanical Room 3
20-Jan-17, Screen Area Grid Line 14 to 16
Grout Stop Log Guides
Install Precast Concrete Panel Walls "East of Col. 14 to ele
Caulking Joints for Precast Wall - East of Col. 14 to Col. 17
Erect Scaffold / Platform Deck for HVAC, Pipe and Firepro
Complete Concrete Topping on hollow Core Deck - Col. 14
Set Sluice Gates & Stop Log Guides
Install Course Bubble Aeration - Screen Influent
PROCURE CATWALK PLATFORMS "Screen & Grit Conv
Deliver Catwalk materials
Screen Channel No. 5, 3 & 1 Concrete Leak Test
Screen Channel Wall Visual Leak Test (Lower Half) for S
Install Roof Insulation and Roof Membrance
Screen Channel Wall Crack Inject (as required)
Paint Coat for Precast Decking Lower Roof - East of Co
Install RWL
Screen Catwalk East of Col. 14 to elev 95.7
Rough In Cable Tray Wall Mounted Under Overhead C
Install HVAC Duct Supply (East)
Install HVAC Duct Exhaust (East)
24-Feb-17, Screen Handling Area Grid Line 10 to 14
Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproo
Install RWL
Install Precast Wall Panels "West of col. 14 to elev 101.5"
Caulking Joints for Precast Wall - West of Col. 14 to Col.
Apply Fire Spray for Columns and Girders West of Col. 14
Paint Coat for Hollow Core Ceiling - West of Col. 14 to C
Paint Coat for Precast Walls - West of Col. 14 to Col. 10
Install Pre-finished Perforated Aluminum Cladding Walls
Install HVAC Duct Supply ( West)
Install HVAC Duct Exhaust (West)
Install Screenings Washer/Compactor
10-Mar-17, Grit Handling Area Grid Line 10 to 14
Install Grit Handling Area Railings
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 2 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
21063025 TOR Grit Handling Catwalk West of Col. 14 to elev 95.7 1 -72 06-Dec-16 06-Dec-16 -21 -1 0%
60090 GOW Install Grit Classifier Grit & Drn Pipe 30 -72 07-Dec-16 26-Jan-17 -31 -1 0%
15060411 GOW Install Plant Water Pipe Col. BB(11-13) 60 -14 07-Dec-16 10-Mar-17 -21 -1 0%
Sluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing Channel
124000 GOW Submit Sluicing Channel 1 -166 28-Nov-16 28-Nov-16 -111 2 0%
124010 OWNER Approve Sluicing Channel 28 -166 29-Nov-16 26-Dec-16 -111 2 0%
Biofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter Area
64060 GOW Deliver BioFilter Media 1 -54 21-Nov-16* 21-Nov-16 -48 0 0%
15022200 WALSH Infill Media 2 -54 21-Nov-16 22-Nov-16 -25 0 0%
15022405 TOR Install FRP Beams 3 55 23-Nov-16 25-Nov-16 0 0%
15021900 TOR FRP Deck 3 32 24-Nov-16 28-Nov-16 -21 0 0%
21063780 GOW Irrigation Pipe 10 -54 23-Nov-16 06-Dec-16 -25 0 0%
15023300 TOR Install FoulAir Pipe Supports 30 -54 23-Nov-16 12-Jan-17 -25 0 0%
15022100 TOR Install Stairs and Hand Rails 10 31 21-Dec-16 12-Jan-17 -22 0 0%
71080 LANCASTERInstall Odour Control Fans & Humidification Unit for New P. Bldg 20 -57 12-Dec-16 17-Jan-17 -15 -4 0%
GeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGenerator
10050300-1 QUAN Install Overhead Cable Trays - Early Work 12 11 25-Oct-16 A 29-Nov-16 -60 -14 42.86%
10050500 QUAN Pull & Terminate Power Wires (Electrical Room #4 to Generator) 25 11 30-Nov-16 12-Jan-17 28 21 0%
SubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstation
21063785 TOR Fab & Delivery New Substation Metal Fence 39 -74 14-Nov-16 16-Jan-17 5 0 0%
Workshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase C
Workshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop Building
StructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructural
21063655 WALSH BEGIN WORKSHOP STRUCTURE 0 -93 21-Nov-16* -34 0 0%
21063570 PETERS Excavate for Foundations 2 -95 12-Dec-16 13-Dec-16 -48 -5 0%
21063790 PETERS Backfill & Compoact Under Slab - Workshop 2 -95 14-Dec-16 15-Dec-16 301 -5 0%
21063595 STEEL Structural Steel Fabrication 30 -84 21-Nov-16 20-Dec-16 0 0%
21063660 Accucut Install Rebar for Workshop Base Slab 5 32 23-Dec-16 27-Dec-16 0%
21063590 STRUCT Form and Pour Base Slab workshop 15 -95 16-Dec-16 16-Jan-17 -49 -5 0%
Electrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical Ductbank
21063600 PETERS Excavate for Electrical Ductbank PB104 to New Workshop 2 -136 21-Nov-16* 22-Nov-16 0 0%
21063620 WALSH Drive all Required Piles 2 -136 23-Nov-16 24-Nov-16 0%
21063645 Accucut Install Rebar for Pile Caps 2 -136 25-Nov-16 26-Nov-16 0%
21063650 STRUCT Form & Pour Pile Caps 2 -136 27-Nov-16 28-Nov-16 0%
21063615 QUAN Install Electrical Ductbank Conduit PB104 to New Workshop 5 -135 29-Nov-16 03-Dec-16 -6 0%
21063605 Accucut Install Rebar for Electrical Ductbank PB104 to New Workshop 6 -136 29-Nov-16 04-Dec-16 -6 0%
21063610 STRUCT Form, Pour & Strip Electrical Ductbank PB104 to New Workshop 3 -136 05-Dec-16 07-Dec-16 -6 0%
21063630 PETERS Backfill & Compact 2 -136 08-Dec-16 09-Dec-16 -6 0%
Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5
15052205 AQUA Apply Waterproofing Conduit 3 tie-in 3 122 20-Dec-16 22-Dec-16 -82 0 0%
Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)
Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)
F10920 QUAN Install Conduit COM-1500 to COM-1505(Genset) 5 211 30-Nov-16 06-Dec-16 4 41 0%
F10930 QUAN Pull Cable COM-1500 to COM-1505(Genset) 2 211 07-Dec-16 08-Dec-16 4 41 0%
J J A S D J A J J A S O J F A J
Grit Handling Catwalk West of Col. 14 to elev 95.7
Install Grit Classifier Grit & Drn Pipe
Install Plant Water Pipe Col. BB(11-13)
26-Dec-16, Sluicing Channel
Submit Sluicing Channel
Approve Sluicing Channel
17-Jan-17, Biofilter Area
Deliver BioFilter Media
Infill Media
Install FRP Beams
FRP Deck
Irrigation Pipe
Install FoulAir Pipe Supports
Install Stairs and Hand Rails
Install Odour Control Fans & Humidification Unit for New
12-Jan-17, Generator
Install Overhead Cable Trays - Early Work
Pull & Terminate Power Wires (Electrical Room #4 to G
16-Jan-17, Substation
Fab & Delivery New Substation Metal Fence
16-Jan-17, Workshop - Early WorkTie to Phase C
16-Jan-17, Workshop Building
16-Jan-17, Structural
BEGIN WORKSHOP STRUCTURE
Excavate for Foundations
Backfill & Compoact Under Slab - Workshop
Structural Steel Fabrication
Install Rebar for Workshop Base Slab
Form and Pour Base Slab workshop
09-Dec-16, Electrical Ductbank
Excavate for Electrical Ductbank PB104 to New Workshop
Drive all Required Piles
Install Rebar for Pile Caps
Form & Pour Pile Caps
Install Electrical Ductbank Conduit PB104 to New Worksho
Install Rebar for Electrical Ductbank PB104 to New Works
Form, Pour & Strip Electrical Ductbank PB104 to New Wo
Backfill & Compact
22-Dec-16, Raw Conduit 3&4&5
Apply Waterproofing Conduit 3 tie-in
08-Dec-16, Ext. Control Rm (Blower Bldg)
08-Dec-16, Electical Room 4 (EX-Screen)
Install Conduit COM-1500 to COM-1505(Genset)
Pull Cable COM-1500 to COM-1505(Genset)
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 3 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
Primary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary Refurb
Primary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary Gallery
non-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activities
12003065 GOW Replace existing Grating with new SS 5 58 14-Nov-16 18-Nov-16 -49 -10 0%
Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8
13003000 WALSH BEGIN PRIMARY GALLERY PHASE 2 0 -79 12-Dec-16 -32 0 0%
13003010 WALSH Service Interuption Request PG8 & PT8 10 -79 12-Dec-16 03-Jan-17 -32 0 0%
CEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPT
Begin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPT
CoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoagu
18000110 WALSH BEGIN COAG SYSTEM - Early work 0 44 30-Nov-16 -49 -23 0%
18000135 Accucut Install Rebar for coagulant Room Slab (GH 5&6) 2 247 02-Dec-16 05-Dec-16 0%
18000130 STRUCT Form and Pour coagulant Slabs (GH 5&6) 4 136 01-Dec-16 06-Dec-16 -43 -23 0%
18000145 Accucut Install Rebar for Coagulant Room Walls (GH 5&6) 2 244 09-Dec-16 12-Dec-16 0%
18000140 STRUCT Form and Pour Coagulant walls (GH 5&6) 7 136 07-Dec-16 15-Dec-16 -43 -23 0%
18000150 GOW Set Tanks (tank 3&4) 2 174 16-Dec-16 19-Dec-16 -43 -23 0%
18000510 GOW Set coag pumps 5 174 20-Dec-16 04-Jan-17 -43 -23 0%
Existing Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen Area
10020500 TRIUMPH Install Wall Cap - Parapet 12 153 14-Nov-16 29-Nov-16 -51 -10 0%
Exist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit Bldg
A20605 Structform Complete new Wing Walls at Influent Channel South 5 71 01-Dec-16 05-Dec-16 -19 0%
A20590 GOW Install Diffuser assembly Grit Influent Channel south 3 44 06-Dec-16 08-Dec-16 -59 -13 0%
156070 QUAN Final Conduit to Power Distribution Panels 2 141 08-Dec-16 09-Dec-16 1 0 0%
52040 GOW Fabricate Phosphorus Metering Pumps (P0810-P0830) 28 274 13-Nov-16 10-Dec-16 0 0 0%
156080 QUAN Pull Power wire Power Distribution Panels 2 141 12-Dec-16 13-Dec-16 1 0 0%
156090 QUAN Tst&Tmn Power Wire To Power Distribution Panels 1 141 14-Dec-16 14-Dec-16 1 0 0%
GeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneral
Construct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass Conduit
11001500 STRUCT FRP Approach Slab for Bypass Conduit 5 135 16-Dec-16 22-Dec-16 -53 0 0%
11001600 WALSH COMPLETE BYPASS CONDUIT 0 135 22-Dec-16 -53 0 0%
Mob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close Out
Change Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost Loading
CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100
CO-5116 OWNER CO39, Walsh Complete work - Conveyor Control Panels 1 264 14-Jul-14 A 14-Nov-16 -19 -10 99.83%
CO-70 OWNER CO70, Walsh Complete work - Stainless Steel Sludge Piping 1 134 18-Feb-15 A 14-Nov-16 -68 -10 75%
CO-5113 OWNER CO20, Walsh Complete work - Crack Repair In Existing Concrete 10 220 15-Jan-14 A 25-Nov-16 -68 -10 50%
CO-75 OWNER CO75, Walsh Complete work - Fireproofing- New Delineation of Change of Material 1 144 08-Apr-15 A 16-Dec-16 -92 11 98.82%
CO-5088 OWNER CO12, Walsh complete work - Door Hardware 10 127 05-Aug-14 A 18-Apr-17 -133 -5 50%
CO-94 OWNER CO94, Walsh Complete work - HVAC/ Electrical RM4 Door/ Kitchen Cabinets 1 112 01-Oct-15 A 09-May-17 -185 -5 0%
CO-5127 OWNER CO38, Walsh Complete work - Sludge Header Connections 149 -28 19-Feb-14 A 22-Jun-17 -40 0 0%
CO-5040 OWNER CO07, Walsh complete work - Larger Consultant Site Office Trailer 0 116 09-Apr-14 A 23-Jun-17 -217 -9 88.49%
CO-5081 OWNER CO08, Walsh complete work - Provide Copier & Printer for AECOM Plant Office (Kenaiden De-Scope) 0 116 04-Apr-14 A 23-Jun-17 -217 -9 99.01%
CO-5103 OWNER CO14, Walsh complete work - Animal Clean-up 1 116 28-Apr-14 A 23-Jun-17 -216 -9 75%
CO-5100 OWNER CO16, Walsh Complete work - Cleaning ConsultantsTrailer 1 116 29-Apr-14 A 23-Jun-17 -216 -9 75%
J J A S D J A J J A S O J F A J
18-Nov-16, Primary Refurb
18-Nov-16, Primary Gallery
18-Nov-16, non-Phase activities
Replace existing Grating with new SS
03-Jan-17, Primary Gallery 8
BEGIN PRIMARY GALLERY PHASE 2
Service Interuption Request PG8 & PT8
04-Jan-17, CEPT
04-Jan-17, Begin CEPT
04-Jan-17, Coagu
BEGIN COAG SYSTEM - Early work
Install Rebar for coagulant Room Slab (GH 5&6)
Form and Pour coagulant Slabs (GH 5&6)
Install Rebar for Coagulant Room Walls (GH 5&6)
Form and Pour Coagulant walls (GH 5&6)
Set Tanks (tank 3&4)
Set coag pumps
29-Nov-16, Existing Screen Area
Install Wall Cap - Parapet
14-Dec-16, Exist Grit Bldg
Complete new Wing Walls at Influent Channel South
Install Diffuser assembly Grit Influent Channel south
Final Conduit to Power Distribution Panels
Fabricate Phosphorus Metering Pumps (P0810-P0830)
Pull Power wire Power Distribution Panels
Tst&Tmn Power Wire To Power Distribution Panels
22-Dec-16, General
22-Dec-16, Construct Bypass Conduit
FRP Approach Slab for Bypass Conduit
COMPLETE BYPASS CONDUIT
24-Apr-18, Mob/Demob a
24-Apr-18, Change Order
24-Apr-18, CO 1-100
CO39, Walsh Complete work - Conveyor Control Panels
CO70, Walsh Complete work - Stainless Steel Sludge Pipin
CO20, Walsh Complete work - Crack Repair In Existing Co
CO75, Walsh Complete work - Fireproofing- New Delinea
CO12, Walsh complete work - Door Hardware
CO94, Walsh Complete work - HVAC/ Electrical
CO38, Walsh Complete work - Sludge Heade
CO07, Walsh complete work - Larger Consul
CO08, Walsh complete work - Provide Copie
CO14, Walsh complete work - Animal Clean-u
CO16, Walsh Complete work - Cleaning Con
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 4 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
CO-5099 OWNER CO19, Walsh Complete work - SI #10 - Updated Electrical 1 116 18-Sep-14 A 23-Jun-17 -680 -9 0%
CO-5161.02 OWNER CO48, Walsh Complete work - Fence and WaterMain Work at Primary Tank 9 0 -29 12-Nov-14 A 22-Nov-17 -321 -2 90%
CO-80 OWNER CO80, Walsh Complete work - Aeration Elbows - change from PVC to Stainless Steel 1 -80 20-Apr-15 A 16-Feb-18 -377 -33 75%
CO-5061 OWNER CO05, Walsh complete Work - Tracing Unknown Services 1 -86 19-Nov-13 A 27-Feb-18 -383 0 75%
CO-5089 OWNER CO17, Walsh Complete work - Trench Drain Grating 1 -86 24-Apr-14 A 27-Feb-18 -383 0 75%
CO-5071 OWNER CO53, Walsh Complete work - Water Connections to Sludge Lines 3 -86 05-May-15 A 27-Feb-18 -383 0 33.02%
CO-5109.01 OWNER CO55, Walsh Complete work - Scum Hopper Connections 2 -86 11-Dec-14 A 27-Feb-18 -383 0 50%
CO-5141 OWNER CO35, Walsh Complete work - Coagulant Control Panels 20 -125 26-Nov-13 A 24-Apr-18 -403 0 0%
Submittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & Fabrication
M&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & Fabrication
QuanQuanQuanQuanQuanQuanQuanQuanQuanQuanQuan
162020 QUAN Order External Lighting 1 84 14-Nov-16 14-Nov-16 -68 -10 0%
164020 QUAN Order Fire System 1 19 14-Nov-16 14-Nov-16 -68 -10 0%
165020 QUAN Order Paging System 1 19 14-Nov-16 14-Nov-16 -68 -10 0%
166020 QUAN Order Phone System 1 19 14-Nov-16 14-Nov-16 -68 -10 0%
78010 OWNER Approve O2 Monitor 3 134 05-Jan-16 A 15-Nov-16 -98 -13 98.63%
79010 OWNER Approve H2S Detector 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68%
80010 OWNER Approve LEL Detector 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68%
81010 OWNER Approve Gas Detector and Controller 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68%
117000 QUAN Submit CCTV System 4 7 23-Nov-14 A 17-Nov-16 -98 -13 99.32%
106149 QUAN Build RPU Panel (0326,27,31,32) 11 230 13-May-16 A 28-Nov-16 -68 -10 81.75%
163010 OWNER Approve Lighting Accessories 28 316 13-Nov-16 10-Dec-16 -72 -13 0%
163020 QUAN Order Lighting Accessories 1 211 12-Dec-16 12-Dec-16 -50 -10 0%
117010 OWNER Approve CCTV System 28 7 17-Nov-16 15-Dec-16 -98 -13 0%
117020 QUAN Order CCTV System 1 5 15-Dec-16 16-Dec-16 -69 -9 0%
168030 VEND Fabricate Heat Tracing 56 39 06-Nov-14 A 07-Jan-17 -98 -13 91.81%
162030 VEND Fabricate External Lighting 56 128 15-Nov-16 09-Jan-17 -98 -14 0%
164030 VEND Fabricate Fire System 56 27 15-Nov-16 09-Jan-17 -98 -14 0%
165030 VEND Fabricate Paging System 56 27 15-Nov-16 09-Jan-17 -98 -14 0%
166030 VEND Fabricate Phone System 56 27 15-Nov-16 09-Jan-17 -98 -14 0%
87030 VEND Fabricate Paddle Flow Switch 70 30 13-Nov-16 21-Jan-17 -98 -13 0%
78030 VEND Fabricate O2 Monitor 70 134 15-Nov-16 24-Jan-17 -98 -13 0%
79030 VEND Fabricate H2S Detector 70 134 15-Nov-16 24-Jan-17 -98 -13 0%
80030 VEND Fabricate LEL Detector 70 134 15-Nov-16 24-Jan-17 -98 -13 0%
81030 VEND Fabricate Gas Detector and Controller 70 134 15-Nov-16 24-Jan-17 -98 -13 0%
117030 VEND Fabricate CCTV System 56 11 16-Dec-16 10-Feb-17 -98 -11 0%
GowGowGowGowGowGowGowGowGowGowGow
Process EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess Equip
74020 OWNER Approve Temp Metering System O&M 3 246 01-Apr-16 A 15-Nov-16 -98 -13 97.71%
74030 OWNER Approve Temp Metering System Training Manual 3 246 01-Apr-16 A 15-Nov-16 -98 -13 97.71%
54200 OWNER Approve Sluice Gate Refurb Training Manual 28 276 13-Nov-16 10-Dec-16 -98 -13 0%
59020 OWNER Approve Progressive Cavity Pump O&M 28 -66 13-Nov-16 10-Dec-16 -98 -13 0%
59030 OWNER Approve Progressive Cavity Pump Training Manual 28 -66 13-Nov-16 10-Dec-16 -98 -13 0%
65020 OWNER Approve Course Bubble Aeration O&M 28 312 13-Nov-16 11-Dec-16 -98 -13 0%
65030 OWNER Approve Course Bubble Aeration Training Manual 28 312 13-Nov-16 11-Dec-16 -98 -13 0%
PipingPipingPipingPipingPipingPipingPipingPipingPipingPipingPiping
J J A S D J A J J A S O J F A J
CO19, Walsh Complete work - SI #10 - Upda
CO48, Walsh Complete work - Fen
CO80, Walsh Complete work
CO05, Walsh complete Work
CO17, Walsh Complete work
CO53, Walsh Complete work
CO55, Walsh Complete work
CO35, Walsh Complete w
15-Apr-17, Submittals & Fabrication
22-Mar-17, M&E Submittals & Fabrication
10-Feb-17, Quan
Order External Lighting
Order Fire System
Order Paging System
Order Phone System
Approve O2 Monitor
Approve H2S Detector
Approve LEL Detector
Approve Gas Detector and Controller
Submit CCTV System
Build RPU Panel (0326,27,31,32)
Approve Lighting Accessories
Order Lighting Accessories
Approve CCTV System
Order CCTV System
Fabricate Heat Tracing
Fabricate External Lighting
Fabricate Fire System
Fabricate Paging System
Fabricate Phone System
Fabricate Paddle Flow Switch
Fabricate O2 Monitor
Fabricate H2S Detector
Fabricate LEL Detector
Fabricate Gas Detector and Controller
Fabricate CCTV System
22-Mar-17, Gow
11-Dec-16, Process Equip
Approve Temp Metering System O&M
Approve Temp Metering System Training Manual
Approve Sluice Gate Refurb Training Manual
Approve Progressive Cavity Pump O&M
Approve Progressive Cavity Pump Training Manual
Approve Course Bubble Aeration O&M
Approve Course Bubble Aeration Training Manual
10-Feb-17, Piping
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 5 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
54205 GOW Deliver Actuators, Gate Refurb 2 -78 30-Jun-15 A 15-Nov-16 -68 -10 90.83%
134010 OWNER Approve Refrigerant Piping System 5 224 13-May-16 A 17-Nov-16 -98 -13 93.5%
134020 GOW Order Refrigerant Piping System 1 150 18-Nov-16 18-Nov-16 -68 -9 0%
134030 VEND Fabricate Refrigerant Piping System 84 227 19-Nov-16 10-Feb-17 -98 -11 0%
HVACHVACHVACHVACHVACHVACHVACHVACHVACHVACHVAC
143090 GOW HVAC Fabrication complete 0 265 27-Feb-14 A 14-Nov-16 -68 -10 100%
140045 GOW Commissioning and Training 15 215 01-Apr-16 A 02-Dec-16 -68 -10 84.04%
131030 VEND Fabricate Heating Water System 26 364 27-Feb-14 A 08-Dec-16 -98 -13 84.97%
132030 VEND Fabricate Heating Glycol System 62 328 28-Feb-14 A 13-Jan-17 -98 -13 70.17%
140040 GOW InstallAutomatic controls 85 145 13-Jul-15 A 22-Mar-17 -68 -10 75.07%
WalshWalshWalshWalshWalshWalshWalshWalshWalshWalshWalsh
A1050 WALSH Submit CEPT Metering Pump O&M 1 316 13-Nov-16 13-Nov-16 -98 -13 0%
A1060 WALSH Submit CEPT Metering Pump Training Manual 1 316 13-Nov-16 13-Nov-16 -98 -13 0%
A1080 WALSH Submit Phosphorus Metering Pumps Training Manual 1 316 13-Nov-16 13-Nov-16 -98 -13 0%
A1150 WALSH Submit RI HD Cent. Pump O&M 1 38 13-Nov-16 13-Nov-16 -98 -13 0%
A1410 WALSH Submit Temp Metering System O&M 1 267 13-Nov-16 13-Nov-16 -98 -13 0%
A1420 WALSH Submit Temp Metering System Training Manual 1 267 13-Nov-16 13-Nov-16 -98 -13 0%
67000 WALSH Submit ResidentialAppliances 1 297 13-Nov-16 13-Nov-16 -98 -13 0%
51020 OWNER Approve CEPT Metering Pump O&M 28 277 13-Nov-16 10-Dec-16 -98 -13 0%
51030 OWNER Approve CEPT Metering Pump Training Manual 28 277 13-Nov-16 10-Dec-16 -98 -13 0%
52020 OWNER Approve Phosphorus Metering Pumps O&M 28 277 13-Nov-16 10-Dec-16 -98 -13 0%
52030 OWNER Approve Phosphorus Metering Pumps Training Manual 28 277 13-Nov-16 10-Dec-16 -98 -13 0%
71020 OWNER Approve Odour Control Fans O&M 28 -81 13-Nov-16 10-Dec-16 -98 -13 0%
71030 OWNER Approve Odour Control Fans Training Manual 28 -81 13-Nov-16 10-Dec-16 -98 -13 0%
118030 OWNER Approve Girder Bridge Cranes Training Manuals 28 317 13-Nov-16 10-Dec-16 -98 -13 0%
67010 OWNER Approve ResidentialAppliances 28 297 14-Nov-16 11-Dec-16 -98 -13 0%
119170 VEND Fabricate Primary Rail Hoist 35 38 10-May-16 A 17-Dec-16 -98 -13 68.15%
119180 WALSH Shop Test Primary Rail Hoist 1 20 19-Dec-16 19-Dec-16 -69 -10 0%
119190 WALSH Deliver Primary Rail Hoist 1 20 20-Dec-16 20-Dec-16 -65 -10 0%
118170 VEND Fabricate 3 Tonne Girder Bridge Crane 40 244 10-May-16 A 22-Dec-16 -98 -13 65.29%
118290 VEND Fabricate 2 Tonne Girder Bridge Crane 40 222 10-May-16 A 22-Dec-16 -98 -13 65.29%
56000 WALSH Submit Grit Lifting Davit 42 -47 15-Jan-15 A 24-Dec-16 -91 -13 82.42%
O&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training Submittals
A1070 WALSH Submit Phosphorus Metering Pumps O&M 1 303 13-Nov-16 13-Nov-16 -98 -13 0%
A1120 WALSH Submit Bulkhead Training Manual 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
A1180 WALSH Submit Submersible Cent. Pump Training Manual 1 71 13-Nov-16 13-Nov-16 -98 -13 0%
A1190 WALSH Submit Progressive Cavity Pump O&M 1 -66 13-Nov-16 13-Nov-16 -98 -13 0%
A1230 WALSH Submit Screenings Washer/Compactor O&M 1 312 13-Nov-16 13-Nov-16 -98 -13 0%
A1240 WALSH Submit Screenings Washer/Compactor Training Manual 1 312 13-Nov-16 13-Nov-16 -98 -13 0%
A1310 WALSH Submit Coarse Bubble Aeration O&M 1 312 13-Nov-16 13-Nov-16 -98 -13 0%
A1320 WALSH Submit Coarse Bubble Aeration Training Manual 1 312 13-Nov-16 13-Nov-16 -98 -13 0%
A1370 WALSH Submit Odour Control Exhaust Stack O&M 1 211 13-Nov-16 13-Nov-16 -98 -13 0%
A1380 WALSH Submit Odour Control Exhaust Stack Training Manual 1 211 13-Nov-16 13-Nov-16 -98 -13 0%
A1490 WALSH Submit Screw Conveyor O&M 1 333 13-Nov-16 13-Nov-16 -98 -13 0%
A1500 WALSH Submit Screw Conveyor Training Manual 1 333 13-Nov-16 13-Nov-16 -98 -13 0%
A1520 WALSH Submit Submersible Screw Conveyor Training Manual 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
J J A S D J A J J A S O J F A J
Deliver Actuators, Gate Refurb
Approve Refrigerant Piping System
Order Refrigerant Piping System
Fabricate Refrigerant Piping System
22-Mar-17, HVAC
HVAC Fabrication complete
Commissioning and Training
Fabricate Heating Water System
Fabricate Heating Glycol System
InstallAutomatic controls
24-Dec-16, Walsh
Submit CEPT Metering Pump O&M
Submit CEPT Metering Pump Training Manual
Submit Phosphorus Metering Pumps Training Manual
Submit RI HD Cent. Pump O&M
Submit Temp Metering System O&M
Submit Temp Metering System Training Manual
Submit ResidentialAppliances
Approve CEPT Metering Pump O&M
Approve CEPT Metering Pump Training Manual
Approve Phosphorus Metering Pumps O&M
Approve Phosphorus Metering Pumps Training Manual
Approve Odour Control Fans O&M
Approve Odour Control Fans Training Manual
Approve Girder Bridge Cranes Training Manuals
Approve ResidentialAppliances
Fabricate Primary Rail Hoist
Shop Test Primary Rail Hoist
Deliver Primary Rail Hoist
Fabricate 3 Tonne Girder Bridge Crane
Fabricate 2 Tonne Girder Bridge Crane
Submit Grit Lifting Davit
15-Apr-17, O&M and Training Submittals
Submit Phosphorus Metering Pumps O&M
Submit Bulkhead Training Manual
Submit Submersible Cent. Pump Training Manual
Submit Progressive Cavity Pump O&M
Submit Screenings Washer/Compactor O&M
Submit Screenings Washer/Compactor Training Manual
Submit Coarse Bubble Aeration O&M
Submit Coarse Bubble Aeration Training Manual
Submit Odour Control Exhaust Stack O&M
Submit Odour Control Exhaust Stack Training Manual
Submit Screw Conveyor O&M
Submit Screw Conveyor Training Manual
Submit Submersible Screw Conveyor Training Manual
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 6 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
A1630 WALSH Submit MCC's 6626 O&M 1 339 13-Nov-16 13-Nov-16 -98 -13 0%
A1430 WALSH Submit Girder Bridge Cranes O&M 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
A1440 WALSH Submit Girder Bridge Cranes Training Manuals 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
A1450 WALSH Submit Monorail Hoist O&M 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
A1460 WALSH Submit Monorail Hoist Training Manuals 1 344 13-Nov-16 13-Nov-16 -98 -13 0%
A1470 WALSH Submit Jib Crane O&M 1 291 13-Nov-16 13-Nov-16 -98 -13 0%
A1480 WALSH Submit Jib Crane Training Manuals 1 291 13-Nov-16 13-Nov-16 -98 -13 0%
A1550 WALSH Submit Transfer Switch O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1560 WALSH Submit Transfer Switch Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1570 WALSH Submit Substation O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1580 WALSH Submit Substation Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1590 WALSH Submit MCC's 6631 & 6634 O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1600 WALSH Submit MCC's 6631 & 6634 Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1610 WALSH Submit MCC's 6674 O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1620 WALSH Submit MCC's 6674 Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0%
A1640 WALSH Submit MCC's 6626 Training Manuals 1 228 14-Nov-16 14-Nov-16 -68 -10 0%
A1650 WALSH Submit MCC's 6921&6922 O&M 1 65 14-Nov-16 14-Nov-16 -68 -10 0%
A1660 WALSH Submit MCC's 6921&6922 Training Manuals 1 65 14-Nov-16 14-Nov-16 -68 -10 0%
A1670 WALSH Submit MCC's 6961 O&M 1 47 14-Nov-16 14-Nov-16 -68 -10 0%
A1680 WALSH Submit MCC's 6961 Training Manuals 1 47 14-Nov-16 14-Nov-16 -68 -10 0%
A1690 WALSH Submit MCC's 6963&6995 O&M 1 67 14-Nov-16 14-Nov-16 -68 -10 0%
A1700 WALSH Submit MCC's 6963&6995 Training Manuals 1 67 14-Nov-16 14-Nov-16 -68 -10 0%
A1710 WALSH Submit MCC's 6962 O&M 1 67 14-Nov-16 14-Nov-16 -68 -10 0%
A1720 WALSH Submit MCC's 6962 Training Manuals 1 67 14-Nov-16 14-Nov-16 -68 -10 0%
A1730 WALSH Submit MCC's 6925&6926 O&M 1 116 14-Nov-16 14-Nov-16 -68 -10 0%
A1740 WALSH Submit MCC's 6925&6926 Training Manuals 1 116 14-Nov-16 14-Nov-16 -68 -10 0%
A1750 WALSH Submit MCC's 6993 O&M 1 148 14-Nov-16 14-Nov-16 -68 -10 0%
A1760 WALSH Submit MCC's 6993 Training Manuals 1 148 14-Nov-16 14-Nov-16 -68 -10 0%
63010 OWNER Submit & Approve Polymer System 28 79 13-Nov-16 10-Dec-16 -98 -13 0%
119020 OWNER Approve Monorail Hoist O&M 28 317 13-Nov-16 10-Dec-16 -98 -13 0%
119030 OWNER Approve Monorail Hoist Training Manuals 28 317 13-Nov-16 10-Dec-16 -98 -13 0%
A1270 WALSH Submit Polymer System O&M 1 282 10-Dec-16 11-Dec-16 -98 -13 0%
A1280 WALSH Submit Polymer System Training Manual 1 282 10-Dec-16 11-Dec-16 -98 -13 0%
63040 VEND Fabricate Polymer System 126 79 10-Dec-16 15-Apr-17 -98 -13 0%
TrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTraining
65130 WALSH Training Course Bubble Aeration 5 227 14-Nov-16 18-Nov-16 -68 -9 0%
76200 WALSH Training SS system 5 -4 14-Nov-16 18-Nov-16 -68 -10 0%
77180 QUAN Training Density Meter 5 -4 14-Nov-16 18-Nov-16 -68 -10 0%
82180 QUAN Training Mag Flow Meter 5 203 14-Nov-16 18-Nov-16 -68 -10 0%
83180 QUAN Training Thermal Flow Meter 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
84180 QUAN Training Ultrasonic CC Flow Meter 5 194 14-Nov-16 18-Nov-16 -68 -10 0%
85180 QUAN Training Ultrasonic OC Flow Meter 5 194 14-Nov-16 18-Nov-16 -68 -10 0%
86180 QUAN Training Venturi Flow Tube 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
88180 QUAN Training Thermal Flow Switch 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
89180 QUAN Training Ultrasound LevelTransmitter 5 196 14-Nov-16 18-Nov-16 -68 -10 0%
90180 QUAN Training Ultrasound MPLevelTransmitter 5 196 14-Nov-16 18-Nov-16 -68 -10 0%
J J A S D J A J J A S O J F A J
Submit MCC's 6626 O&M
Submit Girder Bridge Cranes O&M
Submit Girder Bridge Cranes Training Manuals
Submit Monorail Hoist O&M
Submit Monorail Hoist Training Manuals
Submit Jib Crane O&M
Submit Jib Crane Training Manuals
Submit Transfer Switch O&M
Submit Transfer Switch Training Manuals
Submit Substation O&M
Submit Substation Training Manuals
Submit MCC's 6631 & 6634 O&M
Submit MCC's 6631 & 6634 Training Manuals
Submit MCC's 6674 O&M
Submit MCC's 6674 Training Manuals
Submit MCC's 6626 Training Manuals
Submit MCC's 6921&6922 O&M
Submit MCC's 6921&6922 Training Manuals
Submit MCC's 6961 O&M
Submit MCC's 6961 Training Manuals
Submit MCC's 6963&6995 O&M
Submit MCC's 6963&6995 Training Manuals
Submit MCC's 6962 O&M
Submit MCC's 6962 Training Manuals
Submit MCC's 6925&6926 O&M
Submit MCC's 6925&6926 Training Manuals
Submit MCC's 6993 O&M
Submit MCC's 6993 Training Manuals
Submit & Approve Polymer System
Approve Monorail Hoist O&M
Approve Monorail Hoist Training Manuals
Submit Polymer System O&M
Submit Polymer System Training Manual
Fabricate Polymer System
16-Dec-16, Training
Training Course Bubble Aeration
Training SS system
Training Density Meter
Training Mag Flow Meter
Training Thermal Flow Meter
Training Ultrasonic CC Flow Meter
Training Ultrasonic OC Flow Meter
Training Venturi Flow Tube
Training Thermal Flow Switch
Training Ultrasound LevelTransmitter
Training Ultrasound MPLevelTransmitter
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 7 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
91140 QUAN Training Float Switch (tilt) 5 205 14-Nov-16 18-Nov-16 -68 -10 0%
92180 QUAN Training Pressure Transmitter 5 205 14-Nov-16 18-Nov-16 -68 -10 0%
93180 QUAN Training Diff Pressure Transmitter 5 205 14-Nov-16 18-Nov-16 -68 -10 0%
96180 QUAN Training Pressure Switch 5 205 14-Nov-16 18-Nov-16 -68 -10 0%
98180 QUAN Training Temp. Transmitter/RTD 5 205 14-Nov-16 18-Nov-16 -68 -10 0%
100180 QUAN Training Temp. Switch 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
103180 QUAN Training Motion Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
104180 QUAN Training Smoke Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
105180 QUAN Training Heat Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0%
63240 GOW Training Polymer system 5 189 12-Dec-16 16-Dec-16 -68 -9 0%
Construction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and Fabrication
47520 WALSH Procure RESILIENT FLOORING 0 390 13-Nov-16 13-Nov-16 -41 -13 0%
41200 LAND SUBMIT TOPSOIL AND FINISH GRADING 1 311 13-Nov-16 13-Nov-16 -98 -13 0%
41300 LAND SUBMIT SODDING 1 311 13-Nov-16 13-Nov-16 -98 -13 0%
41400 LAND SUBMIT PLANTING OF TREES, SHRUBS AND GROUND COVERS 1 246 13-Nov-16 13-Nov-16 -98 -13 0%
47200 WALSH SUBMIT GYPSUM BOARD 1 201 13-Nov-16 13-Nov-16 -98 -13 0%
47400 WALSH Submit ACOUSTICAL CEILINGS 1 237 13-Nov-16 13-Nov-16 -98 -13 0%
48200 WALSH Submit EXTERIOR WALL LOUVERS 1 -11 13-Nov-16 13-Nov-16 -98 -13 0%
48300 WALSH Submit EQUIPMENT LOUVERED PENTHOUSE 1 315 13-Nov-16 13-Nov-16 -98 -13 0%
41210 OWNER APPROVE TOPSOIL AND FINISH GRADING 14 311 14-Nov-16 27-Nov-16 -98 -13 0%
41310 OWNER APPROVE SODDING 14 311 14-Nov-16 27-Nov-16 -98 -13 0%
41410 OWNER APPROVE PLANTING OF TREES, SHRUBS AND GROUND COVERS 14 246 14-Nov-16 27-Nov-16 -98 -13 0%
47210 OWNER Approve GYPSUM BOARD 14 201 14-Nov-16 27-Nov-16 -98 -13 0%
47410 OWNER Approve ACOUSTICAL CEILINGS 14 237 14-Nov-16 27-Nov-16 -98 -13 0%
48210 OWNER Approve EXTERIOR WALL LOUVERS 14 -11 14-Nov-16 27-Nov-16 -98 -13 0%
48310 OWNER Approve EQUIPMENT LOUVERED PENTHOUSE 14 315 14-Nov-16 27-Nov-16 -98 -13 0%
47320 WALSH Procure TILES 60 252 13-Nov-16 11-Jan-17 -98 -13 0%
47720 WALSH Procure Chem RESISTANT COATINGS 60 274 13-Nov-16 11-Jan-17 -98 -13 0%
48020 WALSH Procure METAL TOILET PARTITIONS 60 266 13-Nov-16 11-Jan-17 -98 -13 0%
48120 WALSH Procure METAL LOCKERS 60 266 13-Nov-16 11-Jan-17 -98 -13 0%
48420 WALSH Procure WASHROOM ACCESSORIES 60 274 13-Nov-16 11-Jan-17 -98 -13 0%
47220 WALSH Procure GYPSUM BOARD 60 201 28-Nov-16 26-Jan-17 -98 -13 0%
47420 WALSH Procure ACOUSTICAL CEILINGS 60 237 28-Nov-16 26-Jan-17 -98 -13 0%
48220 WALSH Procure EXTERIOR WALL LOUVERS 60 -11 28-Nov-16 26-Jan-17 -98 -13 0%
48320 WALSH Procure EQUIPMENT LOUVERED PENTHOUSE 60 315 28-Nov-16 26-Jan-17 -98 -13 0%
MobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilization
A21170 WALSH Submittals 114 275 03-Sep-13 A 08-Mar-17 -106 -14 90.17%
A21165 WALSH Management of Project 222 168 03-Sep-13 A 23-Jun-17 272 -13 80.01%
A21220 QUAN Quantech Site Mangement 266 75 18-Jul-16 A 05-Aug-17 -98 -13 2.16%
CommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommission
BALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANT
Mechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower Rm
S1040 Complete SCADA for COM-5100 (Mech Rm 6) 75 143 16-Feb-16 A 08-Mar-17 -68 -10 59.68%
Primary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary Gallery
Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9
58170 Loop Check Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16* 14-Nov-16 -67 0 0%
J J A S D J A J J A S O J F A J
Training Float Switch (tilt)
Training Pressure Transmitter
Training Diff Pressure Transmitter
Training Pressure Switch
Training Temp. Transmitter/RTD
Training Temp. Switch
Training Motion Detector
Training Smoke Detector
Training Heat Detector
Training Polymer system
26-Jan-17, Construction Submittals, Approvals and Fab
Procure RESILIENT FLOORING
SUBMIT TOPSOIL AND FINISH GRADING
SUBMIT SODDING
SUBMIT PLANTING OF TREES, SHRUBS AND GROUND
SUBMIT GYPSUM BOARD
Submit ACOUSTICAL CEILINGS
Submit EXTERIOR WALL LOUVERS
Submit EQUIPMENT LOUVERED PENTHOUSE
APPROVE TOPSOIL AND FINISH GRADING
APPROVE SODDING
APPROVE PLANTING OF TREES, SHRUBS AND GROU
Approve GYPSUM BOARD
Approve ACOUSTICAL CEILINGS
Approve EXTERIOR WALL LOUVERS
Approve EQUIPMENT LOUVERED PENTHOUSE
Procure TILES
Procure Chem RESISTANT COATINGS
Procure METAL TOILET PARTITIONS
Procure METAL LOCKERS
Procure WASHROOM ACCESSORIES
Procure GYPSUM BOARD
Procure ACOUSTICAL CEILINGS
Procure EXTERIOR WALL LOUVERS
Procure EQUIPMENT LOUVERED PENTHOUSE
05-Aug-17, Mobilization
Submittals
Management of Project
Quantech Site Mangement
08-Mar-17, Commission
08-Mar-17, BALANCE OF PLANT
08-Mar-17, Mechanical Rm 6/Old Blower Rm
Complete SCADA for COM-5100 (Mech Rm 6)
19-Jan-17, Primary Gallery
19-Jan-17, Gallery 9
Loop Check Submersible Cent. Pump (P-0001&2&5130-31
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 8 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
Activity ID Longest
Path
213060-RESPActivity Name RD Total
Float
Start Finish August 7 -
Baseline Variance
Weekly
Variance
%
Complete
58180 Calibrate Submersible Cent. Pump Instrumentation 1 -79 14-Nov-16 14-Nov-16 -66 0 0%
58190 Equipment Checkout Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16 14-Nov-16 -65 0 0%
58200 Functional Test Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16 14-Nov-16 -63 0 0%
13002660 Commission & Return to Service PT9 14 -78 14-Nov-16 01-Dec-16 -26 0 0%
75220 Performance Test Seal Water Pump (P-4520) 14 193 14-Nov-16 01-Dec-16 -72 0 0%
58210 Performance Test Submersible Cent. Pump (P-0001&2&5130-31) 14 -79 15-Nov-16 02-Dec-16 -63 0 0%
13002670 COMPLETE PRIMARY GALERY PHASE 1 0 -79 02-Dec-16 -27 0 0%
12003105 GOW Commission Seal Water Pumps 5 44 09-Dec-16 15-Dec-16 -59 -13 0%
59240 Performance Test Scum Pump (P2501-2) 14 193 02-Dec-16 21-Dec-16 -64 0 0%
120020 Approve Jib Crane O&M 28 148 14-Nov-16 21-Dec-16 -68 -10 0%
120030 Approve Jib Crane Training Manuals 28 148 14-Nov-16 21-Dec-16 -40 -10 0%
120040 Order Jib Crane 1 148 22-Dec-16 22-Dec-16 -40 -10 0%
21011850 WALSH Performance Test RI HD Cent. Pump (P-3401-3602&0160-70) 14 288 22-Dec-16 04-Jan-17 -86 0 0%
120050 Fabricate Jib Crane 29 223 22-Dec-16 19-Jan-17 -43 0 0%
J J A S D J A J J A S O J F A J
Calibrate Submersible Cent. Pump Instrumentation
Equipment Checkout Submersible Cent. Pump (P-0001&2&
Functional Test Submersible Cent. Pump (P-0001&2&5130
Commission & Return to Service PT9
Performance Test Seal Water Pump (P-4520)
Performance Test Submersible Cent. Pump (P-0001&2&5
COMPLETE PRIMARY GALERY PHASE 1
Commission Seal Water Pumps
Performance Test Scum Pump (P2501-2)
Approve Jib Crane O&M
Approve Jib Crane Training Manuals
Order Jib Crane
Performance Test RI HD Cent. Pump (P-3401-3602&01
Fabricate Jib Crane
Actual Work
Remaining Work
Critical Remaining Work
Milestone
Summary
ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL
Project 12 Week Look Ahead - 1 Week Spotlight
Date Date: 13-Nov-16
page 9 of 9
Layout: I.S 12 WLA 20161115
Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.

More Related Content

Similar to 12FS-18WP ABTP - Bldg P Upgrades and Odour Control Project - 6 Week Look Ahead Report

Nbourdier-lab2-gantt chart with activities-
Nbourdier-lab2-gantt chart with activities-Nbourdier-lab2-gantt chart with activities-
Nbourdier-lab2-gantt chart with activities-Nixzalis Bourdier
 
HSM 2nd July Schedule -All activity
HSM 2nd July Schedule -All activityHSM 2nd July Schedule -All activity
HSM 2nd July Schedule -All activityRoumik Mukherjee
 
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016Ahmed Mehrem
 
Equipment Arrival Status.pptx
Equipment Arrival Status.pptxEquipment Arrival Status.pptx
Equipment Arrival Status.pptxMehmanNasibov1
 
Final Majarrah rev 0
Final Majarrah rev 0Final Majarrah rev 0
Final Majarrah rev 0Ahmed Mehrem
 
Zewail B4 Base Line Schedule All Buildings.pdf
Zewail B4 Base Line Schedule All Buildings.pdfZewail B4 Base Line Schedule All Buildings.pdf
Zewail B4 Base Line Schedule All Buildings.pdfAhmed Mehrem
 
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)Allan Leyte
 
-The PERT Chart-The tendering time schedule for Adar Produced Water Re-injec...
-The PERT Chart-The tendering time schedule for Adar Produced  Water Re-injec...-The PERT Chart-The tendering time schedule for Adar Produced  Water Re-injec...
-The PERT Chart-The tendering time schedule for Adar Produced Water Re-injec...yang lu
 
Bissa Upgrade weekly report 09May2016
Bissa Upgrade weekly report 09May2016Bissa Upgrade weekly report 09May2016
Bissa Upgrade weekly report 09May2016Allan Leyte
 
Programacion 4 semanas
Programacion 4 semanasProgramacion 4 semanas
Programacion 4 semanasAresi2016
 
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2David Hults
 
Shri akash bhai sundarkand wale thermal report
Shri akash bhai sundarkand wale thermal reportShri akash bhai sundarkand wale thermal report
Shri akash bhai sundarkand wale thermal reportEr Akash Saini
 
Project management report of stadium
Project management report of stadiumProject management report of stadium
Project management report of stadiumSLIIT, Sri Lanka
 
CE 561 - Term Project on Primavera P6
CE 561 - Term Project on Primavera P6CE 561 - Term Project on Primavera P6
CE 561 - Term Project on Primavera P6Abhishek Singh
 
AHHS - 6900 Broadway
AHHS - 6900 BroadwayAHHS - 6900 Broadway
AHHS - 6900 Broadwayahcitycouncil
 
Merkinch Welfare Hall Technical Details
Merkinch Welfare Hall Technical DetailsMerkinch Welfare Hall Technical Details
Merkinch Welfare Hall Technical DetailsEdward Brown
 
23. CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)
23.  CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)23.  CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)
23. CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)hepemod733
 

Similar to 12FS-18WP ABTP - Bldg P Upgrades and Odour Control Project - 6 Week Look Ahead Report (20)

Nbourdier-lab2-gantt chart with activities-
Nbourdier-lab2-gantt chart with activities-Nbourdier-lab2-gantt chart with activities-
Nbourdier-lab2-gantt chart with activities-
 
01. P269 - Project Implementation Programme - Rev 00
01. P269 - Project Implementation Programme -  Rev 0001. P269 - Project Implementation Programme -  Rev 00
01. P269 - Project Implementation Programme - Rev 00
 
HSM 2nd July Schedule -All activity
HSM 2nd July Schedule -All activityHSM 2nd July Schedule -All activity
HSM 2nd July Schedule -All activity
 
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016
Zewail b4 base line schedule all buildings (detailed) completion 17 nov 2016
 
Equipment Arrival Status.pptx
Equipment Arrival Status.pptxEquipment Arrival Status.pptx
Equipment Arrival Status.pptx
 
Final Majarrah rev 0
Final Majarrah rev 0Final Majarrah rev 0
Final Majarrah rev 0
 
Zewail B4 Base Line Schedule All Buildings.pdf
Zewail B4 Base Line Schedule All Buildings.pdfZewail B4 Base Line Schedule All Buildings.pdf
Zewail B4 Base Line Schedule All Buildings.pdf
 
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)
Programme Sync with BOQ from contract, Cost & ResEqp Loaded (Initial Stage)
 
-The PERT Chart-The tendering time schedule for Adar Produced Water Re-injec...
-The PERT Chart-The tendering time schedule for Adar Produced  Water Re-injec...-The PERT Chart-The tendering time schedule for Adar Produced  Water Re-injec...
-The PERT Chart-The tendering time schedule for Adar Produced Water Re-injec...
 
Bissa Upgrade weekly report 09May2016
Bissa Upgrade weekly report 09May2016Bissa Upgrade weekly report 09May2016
Bissa Upgrade weekly report 09May2016
 
Programacion 4 semanas
Programacion 4 semanasProgramacion 4 semanas
Programacion 4 semanas
 
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
 
Shri akash bhai sundarkand wale thermal report
Shri akash bhai sundarkand wale thermal reportShri akash bhai sundarkand wale thermal report
Shri akash bhai sundarkand wale thermal report
 
Project management report of stadium
Project management report of stadiumProject management report of stadium
Project management report of stadium
 
CE 561 - Term Project on Primavera P6
CE 561 - Term Project on Primavera P6CE 561 - Term Project on Primavera P6
CE 561 - Term Project on Primavera P6
 
Monthly Progress Report No.13 - September 2011
Monthly Progress Report No.13 - September 2011Monthly Progress Report No.13 - September 2011
Monthly Progress Report No.13 - September 2011
 
AHHS - 6900 Broadway
AHHS - 6900 BroadwayAHHS - 6900 Broadway
AHHS - 6900 Broadway
 
Merkinch Welfare Hall Technical Details
Merkinch Welfare Hall Technical DetailsMerkinch Welfare Hall Technical Details
Merkinch Welfare Hall Technical Details
 
ARB JANADREA 25.01.16 UPDATE PM
ARB JANADREA 25.01.16 UPDATE  PMARB JANADREA 25.01.16 UPDATE  PM
ARB JANADREA 25.01.16 UPDATE PM
 
23. CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)
23.  CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)23.  CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)
23. CIWPF-MPT-WPR-0023_21-Mar-24.pptx (SMARK)
 

12FS-18WP ABTP - Bldg P Upgrades and Odour Control Project - 6 Week Look Ahead Report

  • 1. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete Ashbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation ScheduleAshbridges - Preliminary Mitigation Schedule MilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestonesMilestones M0580 WALSH Complete of Electical Room 4 (EX-Screen) 0 315 08-Dec-16 -3 57 0% M0670 WALSH Start of Primary Gallery 8 0 361 12-Dec-16 -31 24 0% A20750 WALSH SUBSTANTIAL COMPLETION 0 -125 24-Apr-18 78 0 0% New Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen BldgNew Screen Bldg GeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneral BLOW-RM-1095 GOW Ground Floor - Heating Piping 10 220 02-Nov-16 A 25-Nov-16 -44 0 44.44% MECH-RM-1-1045 LANCASTERInstall Down Run of Ductwork Following Pre-cast Panels 20 -24 22-Nov-16 11-Dec-16 0% MECH-RM-1-1025 TROY Ground Floor and Pump Room - Install Fire Protection System 20 -47 28-Nov-16 03-Jan-17 0 0% Screen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump RoomScreen Pump Room PUMP-RM-1030 QUAN Pump Room - Install Cable trays 5 -15 13-Dec-16 19-Dec-16 -63 43 0% PUMP-RM-1040 GOW Pump Room - Install Pump Skids 1 -15 20-Dec-16 20-Dec-16 -63 43 0% PUMP-RM-1050 GOW Pump Room - Complete Tie Ins to Skids 10 -15 21-Dec-16 12-Jan-17 -63 43 0% Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1Electrical Room 1 ELEC-RM-1-CX-130 QUAN Elec Rm #1 - Pull Wiring to MCCs in EL #2 11 -147 28-Nov-16 12-Dec-16 12 0 0% ELEC-RM-1-1070 QUAN Elec Rm #1 - Cable Termination to MCCs in EL#2 11 -147 13-Dec-16 05-Jan-17 21 0 0% Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1Mechanical Room 1 MECH-RM-1-1070 GOW Install Mech Room #1 - Control Wiring 10 32 24-Oct-16 A 25-Nov-16 -3 0 80% MECH-RM-1-1000 LANCASTERInstall Mech Room #1 - HVAC Duct Work 11 -15 18-Oct-16 A 28-Nov-16 -64 -13 80% MECH-RM-1-1030 QUAN Install Mech Room #1 - Cable trays 10 -15 29-Nov-16 12-Dec-16 1 43 0% Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg)Blower Room (Scn Bldg) 73060 GOW Notice Shop Testing Aeration Blowers 6 271 11-Sep-16 A 18-Nov-16 -76 0 91.3% 73070 GOW Shop Test Aeration Blowers 4 181 21-Nov-16 24-Nov-16 -55 0 0% BLOW-RM-1020 TOR Blower Room - Fabricate & InstallALP System Structural Supports 13 -80 13-Nov-16 25-Nov-16 13 0% 73090 GOW Deliver Aeration Blowers 1 272 07-Dec-16 07-Dec-16 -37 0 0% BLOW-RM-1015 GOW Install Blower Room - ALP Piping 26 -80 26-Nov-16 21-Dec-16 -37 0 0% 73075 GOW Install Blower Room - ALP Ductwork 26 250 26-Nov-16 21-Dec-16 0% 21063475 WALSH Complete Rebar for Equipment Pads 2 250 22-Dec-16 23-Dec-16 -1 0% BLOW-RM-1090 GOW Install Blower Room - Insulation 10 9 22-Dec-16 31-Dec-16 -37 0 0% BLOW-RM-1030 QUAN Blower Room - Install Cable trays 20 -57 22-Dec-16 27-Jan-17 -27 0 0% Truck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading AreaTruck Loading Area TRUCK-LB-1030 GOW Truck Loading Bay - Process Piping 21 -102 11-Oct-16 A 12-Dec-16 16 0 40% TRUCK-LB-1010 QUAN Truck Loading Bay - Cable trays 20 -111 28-Nov-16 03-Jan-17 -18 24 0% Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor)Electrical Room 2 (Screen 2nd floor) ADD-1085 PRECAST Install Precast Wall Panel at Low Roof at Elec. & Mech. Rm. 2 1 -93 07-Nov-16 A 14-Nov-16 -30 -1 66.67% 21063895 PAINT Paint inside face of architectural precast panels 2 23 16-Nov-16 17-Nov-16 0% ELEC-RM-2-1010 QUAN Elec Rm #2 - Set MCC's 10 -125 17-Oct-16 A 25-Nov-16 -1 -29 60% ELEC-RM-2-1050 QUAN Elec Rm #2 - Cable Trays 10 -147 08-Nov-16 A 25-Nov-16 24 24 33.33% ELEC-RM-2-1020 QUAN Elec Rm #2 - Set Transformer 5 16 28-Nov-16 02-Dec-16 -1 -1 0% 21063850 MASON Build Partation Block Wall for Elec. Rm 2 & Mech. Rm 2 5 12 28-Nov-16 02-Dec-16 -44 -5 0% 21063900 TRIUMPH Install Roof Over Electrical/Mechanical Room #2 10 19 22-Nov-16 05-Dec-16 0% 21063890 PAINT Paint Block Wall 2 12 05-Dec-16 06-Dec-16 -7 0% 21063905 GOW Set 2 Condensate Units over Electrical Room #2 1 19 06-Dec-16 06-Dec-16 0% ELEC-RM-2-1030 QUAN Elec Rm #2 - Install Control Panel 5 16 05-Dec-16 09-Dec-16 -1 -1 0% J J A S D J A J J A S O J F A J 24-Apr-18, Ashbridges - P 24-Apr-18, Milestones Complete of Electical Room 4 (EX-Screen) Start of Primary Gallery 8 SUBSTANTIAL COMPLET 10-Mar-17, New Screen Bldg 03-Jan-17, General Ground Floor - Heating Piping Install Down Run of Ductwork Following Pre-cast Panels Ground Floor and Pump Room - Install Fire Protection S 12-Jan-17, Screen Pump Room Pump Room - Install Cable trays Pump Room - Install Pump Skids Pump Room - Complete Tie Ins to Skids 05-Jan-17, Electrical Room 1 Elec Rm #1 - Pull Wiring to MCCs in EL #2 Elec Rm #1 - Cable Termination to MCCs in EL#2 12-Dec-16, Mechanical Room 1 Install Mech Room #1 - Control Wiring Install Mech Room #1 - HVAC Duct Work Install Mech Room #1 - Cable trays 27-Jan-17, Blower Room (Scn Bldg) Notice Shop Testing Aeration Blowers Shop Test Aeration Blowers Blower Room - Fabricate & InstallALP System Structural S Deliver Aeration Blowers Install Blower Room - ALP Piping Install Blower Room - ALP Ductwork Complete Rebar for Equipment Pads Install Blower Room - Insulation Blower Room - Install Cable trays 03-Jan-17, Truck Loading Area Truck Loading Bay - Process Piping Truck Loading Bay - Cable trays 09-Dec-16, Electrical Room 2 (Screen 2nd floor) Install Precast Wall Panel at Low Roof at Elec. & Mech. Rm Paint inside face of architectural precast panels Elec Rm #2 - Set MCC's Elec Rm #2 - Cable Trays Elec Rm #2 - Set Transformer Build Partation Block Wall for Elec. Rm 2 & Mech. Rm 2 Install Roof Over Electrical/Mechanical Room #2 Paint Block Wall Set 2 Condensate Units over Electrical Room #2 Elec Rm #2 - Install Control Panel Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 1 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 2. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2Mechanical Room 2 MECH-RM-2-1010 LANCASTERMechanical Room #2 - HVAC Duct Work 4 -23 10-Oct-16 A 17-Nov-16 -10 0 85.71% MECH-RM-2-1020 GOW Mechanical Room #2 - Drainage Services 5 -23 14-Nov-16 18-Nov-16 -6 0 0% MECH-RM-2-1030 GOW Mechanical Room #2 - Process Piping 9 -23 01-Dec-16 13-Dec-16 -13 0 0% MECH-RM-2-1055 INSUL Mechanical Room #2 - Insulation 5 2 14-Dec-16 20-Dec-16 -3 0 0% MECH-RM-2-1060 GOW Mechanical Room #2 -VFD's to AHU 14 -23 14-Dec-16 11-Jan-17 3 0 0% Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse)Mechanical Room 3 (Screen Penthouse) MECH-ROOM-3-1000 GOW Set AHUs and MCC on Equipment Pads 1 -31 14-Nov-16 14-Nov-16 -10 1 0% 15011100 STEEL Install Steel Columns and Girders West of Col. 14 to elev 101.5 Including Metal Deck 10 -31 15-Nov-16 28-Nov-16 -10 -3 0% 15011400 ROOF Install Roof over Metal Decking 5 22 29-Nov-16 05-Dec-16 5 -3 0% ADD-6040 PRECAST Install Precast Wall Panel at High Roof at Mech. Rm. 3 5 -52 09-Dec-16 15-Dec-16 2 0 0% ADD-6035 PAINT Paint Mechanical Room 3 9 -52 16-Dec-16 06-Jan-17 6 0 0% ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16ScreenArea Grid Line 14 to 16 ARS4200650 STRUCT Grout Stop Log Guides 10 -10 08-Jun-16 A 25-Nov-16 -60 -11 91.15% 15010400 PRECAST Install Precast Concrete Panel Walls "East of Col. 14 to elev. 96.04" 9 -34 15-Nov-16 25-Nov-16 -28 1 0% ADD-2020 PRECAST Caulking Joints for Precast Wall - East of Col. 14 to Col. 17 2 28 28-Nov-16 29-Nov-16 1 0% 21063520 Scaffold Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproofing 8 -103 21-Nov-16 30-Nov-16 -37 -8 0% ARS4200655 STRUCT Complete Concrete Topping on hollow Core Deck - Col. 14 to 17 5 71 26-Nov-16 30-Nov-16 0% 15006210 GOW Set Sluice Gates & Stop Log Guides 15 -10 20-Jun-16 A 02-Dec-16 -67 -16 81.93% 65080 GOW Install Course Bubble Aeration - Screen Influent 15 -3 14-Nov-16 02-Dec-16 28 -5 0% 44320 TOR PROCURE CATWALK PLATFORMS "Screen & Grit Conveyor Area" 20 -218 02-Aug-16 A 02-Dec-16 -65 -6 83.74% 15062800 TOR Deliver Catwalk materials 1 -151 05-Dec-16 05-Dec-16 -42 -1 0% ARS4200635 WALSH Screen Channel No. 5, 3 & 1 Concrete Leak Test 10 -3 05-Dec-16 16-Dec-16 -19 0 0% ARS800150 WALSH Screen Channel Wall Visual Leak Test (Lower Half) for Screen Installation 10 -3 05-Dec-16 16-Dec-16 -19 0 0% 21063855 ROOF Install Roof Insulation and Roof Membrance 15 10 28-Nov-16 16-Dec-16 -39 1 0% ARS800160 WALSH Screen Channel Wall Crack Inject (as required) 3 -10 20-Dec-16 22-Dec-16 -30 0 0% ADD-2010 PRECAST Paint Coat for Precast Decking Lower Roof - East of Col. 14 to Col. 17 5 10 19-Dec-16 03-Jan-17 11 0% 15060522 GOW Install RWL 20 -20 01-Dec-16 06-Jan-17 -37 -8 0% 21062980 TOR Screen Catwalk East of Col. 14 to elev 95.7 20 -151 06-Dec-16 11-Jan-17 0 -1 0% 53260 QUAN Rough In Cable Tray Wall Mounted Under Overhead Crane Col. 14 to 17 30 -18 29-Nov-16 18-Jan-17 -29 0 0% 15061165 LANCASTERInstall HVAC Duct Supply (East) 30 -20 01-Dec-16 20-Jan-17 -27 2 0% 15061173 LANCASTERInstall HVAC Duct Exhaust (East) 30 -20 01-Dec-16 20-Jan-17 -27 2 0% Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14Screen HandlingArea Grid Line 10 to 14 21063560 Scaffold Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproofing 5 -107 31-Oct-16 A 18-Nov-16 -44 -8 66.67% 21063065 GOW Install RWL 10 -95 21-Nov-16 02-Dec-16 -29 0 0% 15011300 PRECAST Install Precast Wall Panels "West of col. 14 to elev 101.5" 19 -93 07-Nov-16 A 08-Dec-16 -18 0 20.83% ADD-2050 PRECAST Caulking Joints for Precast Wall - West of Col. 14 to Col. 10 2 37 09-Dec-16 12-Dec-16 0 0% 21062920 FPROOF Apply Fire Spray for Columns and Girders West of Col. 14 to elev 95.7 10 -103 01-Dec-16 14-Dec-16 -37 -8 0% ADD-2060 PAINT Paint Coat for Hollow Core Ceiling - West of Col. 14 to Col. 10 5 30 15-Dec-16 21-Dec-16 -8 0% ADD-2070 PAINT Paint Coat for Precast Walls - West of Col. 14 to Col. 10 5 30 22-Dec-16 06-Jan-17 -7 0% 15011300-1 WALSH Install Pre-finished Perforated Aluminum Cladding Walls "West of col. 14 to elev 101.5" 15 196 09-Dec-16 09-Jan-17 -18 0 0% 15061169 LANCASTERInstall HVAC Duct Supply ( West) 30 -7 21-Nov-16 10-Jan-17 -29 0 0% 15061177 LANCASTERInstall HVAC Duct Exhaust (West) 30 -95 21-Nov-16 10-Jan-17 -29 0 0% 61080 GOW Install Screenings Washer/Compactor 50 -107 07-Dec-16 24-Feb-17 -56 -8 0% Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14Grit HandlingArea Grid Line 10 to 14 21063030 TOR Install Grit Handling Area Railings 1 135 06-Dec-16 06-Dec-16 -21 -1 0% J J A S D J A J J A S O J F A J 11-Jan-17, Mechanical Room 2 Mechanical Room #2 - HVAC Duct Work Mechanical Room #2 - Drainage Services Mechanical Room #2 - Process Piping Mechanical Room #2 - Insulation Mechanical Room #2 -VFD's to AHU 06-Jan-17, Mechanical Room 3 (Screen Penthouse) Set AHUs and MCC on Equipment Pads Install Steel Columns and Girders West of Col. 14 to elev 1 Install Roof over Metal Decking Install Precast Wall Panel at High Roof at Mech. Rm. 3 Paint Mechanical Room 3 20-Jan-17, Screen Area Grid Line 14 to 16 Grout Stop Log Guides Install Precast Concrete Panel Walls "East of Col. 14 to ele Caulking Joints for Precast Wall - East of Col. 14 to Col. 17 Erect Scaffold / Platform Deck for HVAC, Pipe and Firepro Complete Concrete Topping on hollow Core Deck - Col. 14 Set Sluice Gates & Stop Log Guides Install Course Bubble Aeration - Screen Influent PROCURE CATWALK PLATFORMS "Screen & Grit Conv Deliver Catwalk materials Screen Channel No. 5, 3 & 1 Concrete Leak Test Screen Channel Wall Visual Leak Test (Lower Half) for S Install Roof Insulation and Roof Membrance Screen Channel Wall Crack Inject (as required) Paint Coat for Precast Decking Lower Roof - East of Co Install RWL Screen Catwalk East of Col. 14 to elev 95.7 Rough In Cable Tray Wall Mounted Under Overhead C Install HVAC Duct Supply (East) Install HVAC Duct Exhaust (East) 24-Feb-17, Screen Handling Area Grid Line 10 to 14 Erect Scaffold / Platform Deck for HVAC, Pipe and Fireproo Install RWL Install Precast Wall Panels "West of col. 14 to elev 101.5" Caulking Joints for Precast Wall - West of Col. 14 to Col. Apply Fire Spray for Columns and Girders West of Col. 14 Paint Coat for Hollow Core Ceiling - West of Col. 14 to C Paint Coat for Precast Walls - West of Col. 14 to Col. 10 Install Pre-finished Perforated Aluminum Cladding Walls Install HVAC Duct Supply ( West) Install HVAC Duct Exhaust (West) Install Screenings Washer/Compactor 10-Mar-17, Grit Handling Area Grid Line 10 to 14 Install Grit Handling Area Railings Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 2 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 3. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete 21063025 TOR Grit Handling Catwalk West of Col. 14 to elev 95.7 1 -72 06-Dec-16 06-Dec-16 -21 -1 0% 60090 GOW Install Grit Classifier Grit & Drn Pipe 30 -72 07-Dec-16 26-Jan-17 -31 -1 0% 15060411 GOW Install Plant Water Pipe Col. BB(11-13) 60 -14 07-Dec-16 10-Mar-17 -21 -1 0% Sluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing ChannelSluicing Channel 124000 GOW Submit Sluicing Channel 1 -166 28-Nov-16 28-Nov-16 -111 2 0% 124010 OWNER Approve Sluicing Channel 28 -166 29-Nov-16 26-Dec-16 -111 2 0% Biofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter AreaBiofilter Area 64060 GOW Deliver BioFilter Media 1 -54 21-Nov-16* 21-Nov-16 -48 0 0% 15022200 WALSH Infill Media 2 -54 21-Nov-16 22-Nov-16 -25 0 0% 15022405 TOR Install FRP Beams 3 55 23-Nov-16 25-Nov-16 0 0% 15021900 TOR FRP Deck 3 32 24-Nov-16 28-Nov-16 -21 0 0% 21063780 GOW Irrigation Pipe 10 -54 23-Nov-16 06-Dec-16 -25 0 0% 15023300 TOR Install FoulAir Pipe Supports 30 -54 23-Nov-16 12-Jan-17 -25 0 0% 15022100 TOR Install Stairs and Hand Rails 10 31 21-Dec-16 12-Jan-17 -22 0 0% 71080 LANCASTERInstall Odour Control Fans & Humidification Unit for New P. Bldg 20 -57 12-Dec-16 17-Jan-17 -15 -4 0% GeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGeneratorGenerator 10050300-1 QUAN Install Overhead Cable Trays - Early Work 12 11 25-Oct-16 A 29-Nov-16 -60 -14 42.86% 10050500 QUAN Pull & Terminate Power Wires (Electrical Room #4 to Generator) 25 11 30-Nov-16 12-Jan-17 28 21 0% SubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstationSubstation 21063785 TOR Fab & Delivery New Substation Metal Fence 39 -74 14-Nov-16 16-Jan-17 5 0 0% Workshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase CWorkshop - Early Work Tie to Phase C Workshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop BuildingWorkshop Building StructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructuralStructural 21063655 WALSH BEGIN WORKSHOP STRUCTURE 0 -93 21-Nov-16* -34 0 0% 21063570 PETERS Excavate for Foundations 2 -95 12-Dec-16 13-Dec-16 -48 -5 0% 21063790 PETERS Backfill & Compoact Under Slab - Workshop 2 -95 14-Dec-16 15-Dec-16 301 -5 0% 21063595 STEEL Structural Steel Fabrication 30 -84 21-Nov-16 20-Dec-16 0 0% 21063660 Accucut Install Rebar for Workshop Base Slab 5 32 23-Dec-16 27-Dec-16 0% 21063590 STRUCT Form and Pour Base Slab workshop 15 -95 16-Dec-16 16-Jan-17 -49 -5 0% Electrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical DuctbankElectrical Ductbank 21063600 PETERS Excavate for Electrical Ductbank PB104 to New Workshop 2 -136 21-Nov-16* 22-Nov-16 0 0% 21063620 WALSH Drive all Required Piles 2 -136 23-Nov-16 24-Nov-16 0% 21063645 Accucut Install Rebar for Pile Caps 2 -136 25-Nov-16 26-Nov-16 0% 21063650 STRUCT Form & Pour Pile Caps 2 -136 27-Nov-16 28-Nov-16 0% 21063615 QUAN Install Electrical Ductbank Conduit PB104 to New Workshop 5 -135 29-Nov-16 03-Dec-16 -6 0% 21063605 Accucut Install Rebar for Electrical Ductbank PB104 to New Workshop 6 -136 29-Nov-16 04-Dec-16 -6 0% 21063610 STRUCT Form, Pour & Strip Electrical Ductbank PB104 to New Workshop 3 -136 05-Dec-16 07-Dec-16 -6 0% 21063630 PETERS Backfill & Compact 2 -136 08-Dec-16 09-Dec-16 -6 0% Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5Raw Conduit 3&4&5 15052205 AQUA Apply Waterproofing Conduit 3 tie-in 3 122 20-Dec-16 22-Dec-16 -82 0 0% Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg)Ext. Control Rm (Blower Bldg) Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen)Electical Room 4 (EX-Screen) F10920 QUAN Install Conduit COM-1500 to COM-1505(Genset) 5 211 30-Nov-16 06-Dec-16 4 41 0% F10930 QUAN Pull Cable COM-1500 to COM-1505(Genset) 2 211 07-Dec-16 08-Dec-16 4 41 0% J J A S D J A J J A S O J F A J Grit Handling Catwalk West of Col. 14 to elev 95.7 Install Grit Classifier Grit & Drn Pipe Install Plant Water Pipe Col. BB(11-13) 26-Dec-16, Sluicing Channel Submit Sluicing Channel Approve Sluicing Channel 17-Jan-17, Biofilter Area Deliver BioFilter Media Infill Media Install FRP Beams FRP Deck Irrigation Pipe Install FoulAir Pipe Supports Install Stairs and Hand Rails Install Odour Control Fans & Humidification Unit for New 12-Jan-17, Generator Install Overhead Cable Trays - Early Work Pull & Terminate Power Wires (Electrical Room #4 to G 16-Jan-17, Substation Fab & Delivery New Substation Metal Fence 16-Jan-17, Workshop - Early WorkTie to Phase C 16-Jan-17, Workshop Building 16-Jan-17, Structural BEGIN WORKSHOP STRUCTURE Excavate for Foundations Backfill & Compoact Under Slab - Workshop Structural Steel Fabrication Install Rebar for Workshop Base Slab Form and Pour Base Slab workshop 09-Dec-16, Electrical Ductbank Excavate for Electrical Ductbank PB104 to New Workshop Drive all Required Piles Install Rebar for Pile Caps Form & Pour Pile Caps Install Electrical Ductbank Conduit PB104 to New Worksho Install Rebar for Electrical Ductbank PB104 to New Works Form, Pour & Strip Electrical Ductbank PB104 to New Wo Backfill & Compact 22-Dec-16, Raw Conduit 3&4&5 Apply Waterproofing Conduit 3 tie-in 08-Dec-16, Ext. Control Rm (Blower Bldg) 08-Dec-16, Electical Room 4 (EX-Screen) Install Conduit COM-1500 to COM-1505(Genset) Pull Cable COM-1500 to COM-1505(Genset) Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 3 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 4. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete Primary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary RefurbPrimary Refurb Primary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary Gallery non-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activitiesnon-Phase activities 12003065 GOW Replace existing Grating with new SS 5 58 14-Nov-16 18-Nov-16 -49 -10 0% Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8Primary Gallery 8 13003000 WALSH BEGIN PRIMARY GALLERY PHASE 2 0 -79 12-Dec-16 -32 0 0% 13003010 WALSH Service Interuption Request PG8 & PT8 10 -79 12-Dec-16 03-Jan-17 -32 0 0% CEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPTCEPT Begin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPTBegin CEPT CoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoaguCoagu 18000110 WALSH BEGIN COAG SYSTEM - Early work 0 44 30-Nov-16 -49 -23 0% 18000135 Accucut Install Rebar for coagulant Room Slab (GH 5&6) 2 247 02-Dec-16 05-Dec-16 0% 18000130 STRUCT Form and Pour coagulant Slabs (GH 5&6) 4 136 01-Dec-16 06-Dec-16 -43 -23 0% 18000145 Accucut Install Rebar for Coagulant Room Walls (GH 5&6) 2 244 09-Dec-16 12-Dec-16 0% 18000140 STRUCT Form and Pour Coagulant walls (GH 5&6) 7 136 07-Dec-16 15-Dec-16 -43 -23 0% 18000150 GOW Set Tanks (tank 3&4) 2 174 16-Dec-16 19-Dec-16 -43 -23 0% 18000510 GOW Set coag pumps 5 174 20-Dec-16 04-Jan-17 -43 -23 0% Existing Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen AreaExisting Screen Area 10020500 TRIUMPH Install Wall Cap - Parapet 12 153 14-Nov-16 29-Nov-16 -51 -10 0% Exist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit BldgExist Grit Bldg A20605 Structform Complete new Wing Walls at Influent Channel South 5 71 01-Dec-16 05-Dec-16 -19 0% A20590 GOW Install Diffuser assembly Grit Influent Channel south 3 44 06-Dec-16 08-Dec-16 -59 -13 0% 156070 QUAN Final Conduit to Power Distribution Panels 2 141 08-Dec-16 09-Dec-16 1 0 0% 52040 GOW Fabricate Phosphorus Metering Pumps (P0810-P0830) 28 274 13-Nov-16 10-Dec-16 0 0 0% 156080 QUAN Pull Power wire Power Distribution Panels 2 141 12-Dec-16 13-Dec-16 1 0 0% 156090 QUAN Tst&Tmn Power Wire To Power Distribution Panels 1 141 14-Dec-16 14-Dec-16 1 0 0% GeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneralGeneral Construct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass ConduitConstruct Bypass Conduit 11001500 STRUCT FRP Approach Slab for Bypass Conduit 5 135 16-Dec-16 22-Dec-16 -53 0 0% 11001600 WALSH COMPLETE BYPASS CONDUIT 0 135 22-Dec-16 -53 0 0% Mob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close OutMob/Demob and Close Out Change Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost LoadingChange Order Cost Loading CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100CO 1-100 CO-5116 OWNER CO39, Walsh Complete work - Conveyor Control Panels 1 264 14-Jul-14 A 14-Nov-16 -19 -10 99.83% CO-70 OWNER CO70, Walsh Complete work - Stainless Steel Sludge Piping 1 134 18-Feb-15 A 14-Nov-16 -68 -10 75% CO-5113 OWNER CO20, Walsh Complete work - Crack Repair In Existing Concrete 10 220 15-Jan-14 A 25-Nov-16 -68 -10 50% CO-75 OWNER CO75, Walsh Complete work - Fireproofing- New Delineation of Change of Material 1 144 08-Apr-15 A 16-Dec-16 -92 11 98.82% CO-5088 OWNER CO12, Walsh complete work - Door Hardware 10 127 05-Aug-14 A 18-Apr-17 -133 -5 50% CO-94 OWNER CO94, Walsh Complete work - HVAC/ Electrical RM4 Door/ Kitchen Cabinets 1 112 01-Oct-15 A 09-May-17 -185 -5 0% CO-5127 OWNER CO38, Walsh Complete work - Sludge Header Connections 149 -28 19-Feb-14 A 22-Jun-17 -40 0 0% CO-5040 OWNER CO07, Walsh complete work - Larger Consultant Site Office Trailer 0 116 09-Apr-14 A 23-Jun-17 -217 -9 88.49% CO-5081 OWNER CO08, Walsh complete work - Provide Copier & Printer for AECOM Plant Office (Kenaiden De-Scope) 0 116 04-Apr-14 A 23-Jun-17 -217 -9 99.01% CO-5103 OWNER CO14, Walsh complete work - Animal Clean-up 1 116 28-Apr-14 A 23-Jun-17 -216 -9 75% CO-5100 OWNER CO16, Walsh Complete work - Cleaning ConsultantsTrailer 1 116 29-Apr-14 A 23-Jun-17 -216 -9 75% J J A S D J A J J A S O J F A J 18-Nov-16, Primary Refurb 18-Nov-16, Primary Gallery 18-Nov-16, non-Phase activities Replace existing Grating with new SS 03-Jan-17, Primary Gallery 8 BEGIN PRIMARY GALLERY PHASE 2 Service Interuption Request PG8 & PT8 04-Jan-17, CEPT 04-Jan-17, Begin CEPT 04-Jan-17, Coagu BEGIN COAG SYSTEM - Early work Install Rebar for coagulant Room Slab (GH 5&6) Form and Pour coagulant Slabs (GH 5&6) Install Rebar for Coagulant Room Walls (GH 5&6) Form and Pour Coagulant walls (GH 5&6) Set Tanks (tank 3&4) Set coag pumps 29-Nov-16, Existing Screen Area Install Wall Cap - Parapet 14-Dec-16, Exist Grit Bldg Complete new Wing Walls at Influent Channel South Install Diffuser assembly Grit Influent Channel south Final Conduit to Power Distribution Panels Fabricate Phosphorus Metering Pumps (P0810-P0830) Pull Power wire Power Distribution Panels Tst&Tmn Power Wire To Power Distribution Panels 22-Dec-16, General 22-Dec-16, Construct Bypass Conduit FRP Approach Slab for Bypass Conduit COMPLETE BYPASS CONDUIT 24-Apr-18, Mob/Demob a 24-Apr-18, Change Order 24-Apr-18, CO 1-100 CO39, Walsh Complete work - Conveyor Control Panels CO70, Walsh Complete work - Stainless Steel Sludge Pipin CO20, Walsh Complete work - Crack Repair In Existing Co CO75, Walsh Complete work - Fireproofing- New Delinea CO12, Walsh complete work - Door Hardware CO94, Walsh Complete work - HVAC/ Electrical CO38, Walsh Complete work - Sludge Heade CO07, Walsh complete work - Larger Consul CO08, Walsh complete work - Provide Copie CO14, Walsh complete work - Animal Clean-u CO16, Walsh Complete work - Cleaning Con Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 4 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 5. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete CO-5099 OWNER CO19, Walsh Complete work - SI #10 - Updated Electrical 1 116 18-Sep-14 A 23-Jun-17 -680 -9 0% CO-5161.02 OWNER CO48, Walsh Complete work - Fence and WaterMain Work at Primary Tank 9 0 -29 12-Nov-14 A 22-Nov-17 -321 -2 90% CO-80 OWNER CO80, Walsh Complete work - Aeration Elbows - change from PVC to Stainless Steel 1 -80 20-Apr-15 A 16-Feb-18 -377 -33 75% CO-5061 OWNER CO05, Walsh complete Work - Tracing Unknown Services 1 -86 19-Nov-13 A 27-Feb-18 -383 0 75% CO-5089 OWNER CO17, Walsh Complete work - Trench Drain Grating 1 -86 24-Apr-14 A 27-Feb-18 -383 0 75% CO-5071 OWNER CO53, Walsh Complete work - Water Connections to Sludge Lines 3 -86 05-May-15 A 27-Feb-18 -383 0 33.02% CO-5109.01 OWNER CO55, Walsh Complete work - Scum Hopper Connections 2 -86 11-Dec-14 A 27-Feb-18 -383 0 50% CO-5141 OWNER CO35, Walsh Complete work - Coagulant Control Panels 20 -125 26-Nov-13 A 24-Apr-18 -403 0 0% Submittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & FabricationSubmittals & Fabrication M&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & FabricationM&E Submittals & Fabrication QuanQuanQuanQuanQuanQuanQuanQuanQuanQuanQuan 162020 QUAN Order External Lighting 1 84 14-Nov-16 14-Nov-16 -68 -10 0% 164020 QUAN Order Fire System 1 19 14-Nov-16 14-Nov-16 -68 -10 0% 165020 QUAN Order Paging System 1 19 14-Nov-16 14-Nov-16 -68 -10 0% 166020 QUAN Order Phone System 1 19 14-Nov-16 14-Nov-16 -68 -10 0% 78010 OWNER Approve O2 Monitor 3 134 05-Jan-16 A 15-Nov-16 -98 -13 98.63% 79010 OWNER Approve H2S Detector 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68% 80010 OWNER Approve LEL Detector 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68% 81010 OWNER Approve Gas Detector and Controller 3 134 04-Mar-14 A 15-Nov-16 -98 -13 99.68% 117000 QUAN Submit CCTV System 4 7 23-Nov-14 A 17-Nov-16 -98 -13 99.32% 106149 QUAN Build RPU Panel (0326,27,31,32) 11 230 13-May-16 A 28-Nov-16 -68 -10 81.75% 163010 OWNER Approve Lighting Accessories 28 316 13-Nov-16 10-Dec-16 -72 -13 0% 163020 QUAN Order Lighting Accessories 1 211 12-Dec-16 12-Dec-16 -50 -10 0% 117010 OWNER Approve CCTV System 28 7 17-Nov-16 15-Dec-16 -98 -13 0% 117020 QUAN Order CCTV System 1 5 15-Dec-16 16-Dec-16 -69 -9 0% 168030 VEND Fabricate Heat Tracing 56 39 06-Nov-14 A 07-Jan-17 -98 -13 91.81% 162030 VEND Fabricate External Lighting 56 128 15-Nov-16 09-Jan-17 -98 -14 0% 164030 VEND Fabricate Fire System 56 27 15-Nov-16 09-Jan-17 -98 -14 0% 165030 VEND Fabricate Paging System 56 27 15-Nov-16 09-Jan-17 -98 -14 0% 166030 VEND Fabricate Phone System 56 27 15-Nov-16 09-Jan-17 -98 -14 0% 87030 VEND Fabricate Paddle Flow Switch 70 30 13-Nov-16 21-Jan-17 -98 -13 0% 78030 VEND Fabricate O2 Monitor 70 134 15-Nov-16 24-Jan-17 -98 -13 0% 79030 VEND Fabricate H2S Detector 70 134 15-Nov-16 24-Jan-17 -98 -13 0% 80030 VEND Fabricate LEL Detector 70 134 15-Nov-16 24-Jan-17 -98 -13 0% 81030 VEND Fabricate Gas Detector and Controller 70 134 15-Nov-16 24-Jan-17 -98 -13 0% 117030 VEND Fabricate CCTV System 56 11 16-Dec-16 10-Feb-17 -98 -11 0% GowGowGowGowGowGowGowGowGowGowGow Process EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess EquipProcess Equip 74020 OWNER Approve Temp Metering System O&M 3 246 01-Apr-16 A 15-Nov-16 -98 -13 97.71% 74030 OWNER Approve Temp Metering System Training Manual 3 246 01-Apr-16 A 15-Nov-16 -98 -13 97.71% 54200 OWNER Approve Sluice Gate Refurb Training Manual 28 276 13-Nov-16 10-Dec-16 -98 -13 0% 59020 OWNER Approve Progressive Cavity Pump O&M 28 -66 13-Nov-16 10-Dec-16 -98 -13 0% 59030 OWNER Approve Progressive Cavity Pump Training Manual 28 -66 13-Nov-16 10-Dec-16 -98 -13 0% 65020 OWNER Approve Course Bubble Aeration O&M 28 312 13-Nov-16 11-Dec-16 -98 -13 0% 65030 OWNER Approve Course Bubble Aeration Training Manual 28 312 13-Nov-16 11-Dec-16 -98 -13 0% PipingPipingPipingPipingPipingPipingPipingPipingPipingPipingPiping J J A S D J A J J A S O J F A J CO19, Walsh Complete work - SI #10 - Upda CO48, Walsh Complete work - Fen CO80, Walsh Complete work CO05, Walsh complete Work CO17, Walsh Complete work CO53, Walsh Complete work CO55, Walsh Complete work CO35, Walsh Complete w 15-Apr-17, Submittals & Fabrication 22-Mar-17, M&E Submittals & Fabrication 10-Feb-17, Quan Order External Lighting Order Fire System Order Paging System Order Phone System Approve O2 Monitor Approve H2S Detector Approve LEL Detector Approve Gas Detector and Controller Submit CCTV System Build RPU Panel (0326,27,31,32) Approve Lighting Accessories Order Lighting Accessories Approve CCTV System Order CCTV System Fabricate Heat Tracing Fabricate External Lighting Fabricate Fire System Fabricate Paging System Fabricate Phone System Fabricate Paddle Flow Switch Fabricate O2 Monitor Fabricate H2S Detector Fabricate LEL Detector Fabricate Gas Detector and Controller Fabricate CCTV System 22-Mar-17, Gow 11-Dec-16, Process Equip Approve Temp Metering System O&M Approve Temp Metering System Training Manual Approve Sluice Gate Refurb Training Manual Approve Progressive Cavity Pump O&M Approve Progressive Cavity Pump Training Manual Approve Course Bubble Aeration O&M Approve Course Bubble Aeration Training Manual 10-Feb-17, Piping Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 5 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 6. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete 54205 GOW Deliver Actuators, Gate Refurb 2 -78 30-Jun-15 A 15-Nov-16 -68 -10 90.83% 134010 OWNER Approve Refrigerant Piping System 5 224 13-May-16 A 17-Nov-16 -98 -13 93.5% 134020 GOW Order Refrigerant Piping System 1 150 18-Nov-16 18-Nov-16 -68 -9 0% 134030 VEND Fabricate Refrigerant Piping System 84 227 19-Nov-16 10-Feb-17 -98 -11 0% HVACHVACHVACHVACHVACHVACHVACHVACHVACHVACHVAC 143090 GOW HVAC Fabrication complete 0 265 27-Feb-14 A 14-Nov-16 -68 -10 100% 140045 GOW Commissioning and Training 15 215 01-Apr-16 A 02-Dec-16 -68 -10 84.04% 131030 VEND Fabricate Heating Water System 26 364 27-Feb-14 A 08-Dec-16 -98 -13 84.97% 132030 VEND Fabricate Heating Glycol System 62 328 28-Feb-14 A 13-Jan-17 -98 -13 70.17% 140040 GOW InstallAutomatic controls 85 145 13-Jul-15 A 22-Mar-17 -68 -10 75.07% WalshWalshWalshWalshWalshWalshWalshWalshWalshWalshWalsh A1050 WALSH Submit CEPT Metering Pump O&M 1 316 13-Nov-16 13-Nov-16 -98 -13 0% A1060 WALSH Submit CEPT Metering Pump Training Manual 1 316 13-Nov-16 13-Nov-16 -98 -13 0% A1080 WALSH Submit Phosphorus Metering Pumps Training Manual 1 316 13-Nov-16 13-Nov-16 -98 -13 0% A1150 WALSH Submit RI HD Cent. Pump O&M 1 38 13-Nov-16 13-Nov-16 -98 -13 0% A1410 WALSH Submit Temp Metering System O&M 1 267 13-Nov-16 13-Nov-16 -98 -13 0% A1420 WALSH Submit Temp Metering System Training Manual 1 267 13-Nov-16 13-Nov-16 -98 -13 0% 67000 WALSH Submit ResidentialAppliances 1 297 13-Nov-16 13-Nov-16 -98 -13 0% 51020 OWNER Approve CEPT Metering Pump O&M 28 277 13-Nov-16 10-Dec-16 -98 -13 0% 51030 OWNER Approve CEPT Metering Pump Training Manual 28 277 13-Nov-16 10-Dec-16 -98 -13 0% 52020 OWNER Approve Phosphorus Metering Pumps O&M 28 277 13-Nov-16 10-Dec-16 -98 -13 0% 52030 OWNER Approve Phosphorus Metering Pumps Training Manual 28 277 13-Nov-16 10-Dec-16 -98 -13 0% 71020 OWNER Approve Odour Control Fans O&M 28 -81 13-Nov-16 10-Dec-16 -98 -13 0% 71030 OWNER Approve Odour Control Fans Training Manual 28 -81 13-Nov-16 10-Dec-16 -98 -13 0% 118030 OWNER Approve Girder Bridge Cranes Training Manuals 28 317 13-Nov-16 10-Dec-16 -98 -13 0% 67010 OWNER Approve ResidentialAppliances 28 297 14-Nov-16 11-Dec-16 -98 -13 0% 119170 VEND Fabricate Primary Rail Hoist 35 38 10-May-16 A 17-Dec-16 -98 -13 68.15% 119180 WALSH Shop Test Primary Rail Hoist 1 20 19-Dec-16 19-Dec-16 -69 -10 0% 119190 WALSH Deliver Primary Rail Hoist 1 20 20-Dec-16 20-Dec-16 -65 -10 0% 118170 VEND Fabricate 3 Tonne Girder Bridge Crane 40 244 10-May-16 A 22-Dec-16 -98 -13 65.29% 118290 VEND Fabricate 2 Tonne Girder Bridge Crane 40 222 10-May-16 A 22-Dec-16 -98 -13 65.29% 56000 WALSH Submit Grit Lifting Davit 42 -47 15-Jan-15 A 24-Dec-16 -91 -13 82.42% O&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training SubmittalsO&M and Training Submittals A1070 WALSH Submit Phosphorus Metering Pumps O&M 1 303 13-Nov-16 13-Nov-16 -98 -13 0% A1120 WALSH Submit Bulkhead Training Manual 1 344 13-Nov-16 13-Nov-16 -98 -13 0% A1180 WALSH Submit Submersible Cent. Pump Training Manual 1 71 13-Nov-16 13-Nov-16 -98 -13 0% A1190 WALSH Submit Progressive Cavity Pump O&M 1 -66 13-Nov-16 13-Nov-16 -98 -13 0% A1230 WALSH Submit Screenings Washer/Compactor O&M 1 312 13-Nov-16 13-Nov-16 -98 -13 0% A1240 WALSH Submit Screenings Washer/Compactor Training Manual 1 312 13-Nov-16 13-Nov-16 -98 -13 0% A1310 WALSH Submit Coarse Bubble Aeration O&M 1 312 13-Nov-16 13-Nov-16 -98 -13 0% A1320 WALSH Submit Coarse Bubble Aeration Training Manual 1 312 13-Nov-16 13-Nov-16 -98 -13 0% A1370 WALSH Submit Odour Control Exhaust Stack O&M 1 211 13-Nov-16 13-Nov-16 -98 -13 0% A1380 WALSH Submit Odour Control Exhaust Stack Training Manual 1 211 13-Nov-16 13-Nov-16 -98 -13 0% A1490 WALSH Submit Screw Conveyor O&M 1 333 13-Nov-16 13-Nov-16 -98 -13 0% A1500 WALSH Submit Screw Conveyor Training Manual 1 333 13-Nov-16 13-Nov-16 -98 -13 0% A1520 WALSH Submit Submersible Screw Conveyor Training Manual 1 344 13-Nov-16 13-Nov-16 -98 -13 0% J J A S D J A J J A S O J F A J Deliver Actuators, Gate Refurb Approve Refrigerant Piping System Order Refrigerant Piping System Fabricate Refrigerant Piping System 22-Mar-17, HVAC HVAC Fabrication complete Commissioning and Training Fabricate Heating Water System Fabricate Heating Glycol System InstallAutomatic controls 24-Dec-16, Walsh Submit CEPT Metering Pump O&M Submit CEPT Metering Pump Training Manual Submit Phosphorus Metering Pumps Training Manual Submit RI HD Cent. Pump O&M Submit Temp Metering System O&M Submit Temp Metering System Training Manual Submit ResidentialAppliances Approve CEPT Metering Pump O&M Approve CEPT Metering Pump Training Manual Approve Phosphorus Metering Pumps O&M Approve Phosphorus Metering Pumps Training Manual Approve Odour Control Fans O&M Approve Odour Control Fans Training Manual Approve Girder Bridge Cranes Training Manuals Approve ResidentialAppliances Fabricate Primary Rail Hoist Shop Test Primary Rail Hoist Deliver Primary Rail Hoist Fabricate 3 Tonne Girder Bridge Crane Fabricate 2 Tonne Girder Bridge Crane Submit Grit Lifting Davit 15-Apr-17, O&M and Training Submittals Submit Phosphorus Metering Pumps O&M Submit Bulkhead Training Manual Submit Submersible Cent. Pump Training Manual Submit Progressive Cavity Pump O&M Submit Screenings Washer/Compactor O&M Submit Screenings Washer/Compactor Training Manual Submit Coarse Bubble Aeration O&M Submit Coarse Bubble Aeration Training Manual Submit Odour Control Exhaust Stack O&M Submit Odour Control Exhaust Stack Training Manual Submit Screw Conveyor O&M Submit Screw Conveyor Training Manual Submit Submersible Screw Conveyor Training Manual Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 6 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 7. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete A1630 WALSH Submit MCC's 6626 O&M 1 339 13-Nov-16 13-Nov-16 -98 -13 0% A1430 WALSH Submit Girder Bridge Cranes O&M 1 344 13-Nov-16 13-Nov-16 -98 -13 0% A1440 WALSH Submit Girder Bridge Cranes Training Manuals 1 344 13-Nov-16 13-Nov-16 -98 -13 0% A1450 WALSH Submit Monorail Hoist O&M 1 344 13-Nov-16 13-Nov-16 -98 -13 0% A1460 WALSH Submit Monorail Hoist Training Manuals 1 344 13-Nov-16 13-Nov-16 -98 -13 0% A1470 WALSH Submit Jib Crane O&M 1 291 13-Nov-16 13-Nov-16 -98 -13 0% A1480 WALSH Submit Jib Crane Training Manuals 1 291 13-Nov-16 13-Nov-16 -98 -13 0% A1550 WALSH Submit Transfer Switch O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1560 WALSH Submit Transfer Switch Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1570 WALSH Submit Substation O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1580 WALSH Submit Substation Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1590 WALSH Submit MCC's 6631 & 6634 O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1600 WALSH Submit MCC's 6631 & 6634 Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1610 WALSH Submit MCC's 6674 O&M 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1620 WALSH Submit MCC's 6674 Training Manuals 1 231 14-Nov-16 14-Nov-16 -68 -10 0% A1640 WALSH Submit MCC's 6626 Training Manuals 1 228 14-Nov-16 14-Nov-16 -68 -10 0% A1650 WALSH Submit MCC's 6921&6922 O&M 1 65 14-Nov-16 14-Nov-16 -68 -10 0% A1660 WALSH Submit MCC's 6921&6922 Training Manuals 1 65 14-Nov-16 14-Nov-16 -68 -10 0% A1670 WALSH Submit MCC's 6961 O&M 1 47 14-Nov-16 14-Nov-16 -68 -10 0% A1680 WALSH Submit MCC's 6961 Training Manuals 1 47 14-Nov-16 14-Nov-16 -68 -10 0% A1690 WALSH Submit MCC's 6963&6995 O&M 1 67 14-Nov-16 14-Nov-16 -68 -10 0% A1700 WALSH Submit MCC's 6963&6995 Training Manuals 1 67 14-Nov-16 14-Nov-16 -68 -10 0% A1710 WALSH Submit MCC's 6962 O&M 1 67 14-Nov-16 14-Nov-16 -68 -10 0% A1720 WALSH Submit MCC's 6962 Training Manuals 1 67 14-Nov-16 14-Nov-16 -68 -10 0% A1730 WALSH Submit MCC's 6925&6926 O&M 1 116 14-Nov-16 14-Nov-16 -68 -10 0% A1740 WALSH Submit MCC's 6925&6926 Training Manuals 1 116 14-Nov-16 14-Nov-16 -68 -10 0% A1750 WALSH Submit MCC's 6993 O&M 1 148 14-Nov-16 14-Nov-16 -68 -10 0% A1760 WALSH Submit MCC's 6993 Training Manuals 1 148 14-Nov-16 14-Nov-16 -68 -10 0% 63010 OWNER Submit & Approve Polymer System 28 79 13-Nov-16 10-Dec-16 -98 -13 0% 119020 OWNER Approve Monorail Hoist O&M 28 317 13-Nov-16 10-Dec-16 -98 -13 0% 119030 OWNER Approve Monorail Hoist Training Manuals 28 317 13-Nov-16 10-Dec-16 -98 -13 0% A1270 WALSH Submit Polymer System O&M 1 282 10-Dec-16 11-Dec-16 -98 -13 0% A1280 WALSH Submit Polymer System Training Manual 1 282 10-Dec-16 11-Dec-16 -98 -13 0% 63040 VEND Fabricate Polymer System 126 79 10-Dec-16 15-Apr-17 -98 -13 0% TrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTrainingTraining 65130 WALSH Training Course Bubble Aeration 5 227 14-Nov-16 18-Nov-16 -68 -9 0% 76200 WALSH Training SS system 5 -4 14-Nov-16 18-Nov-16 -68 -10 0% 77180 QUAN Training Density Meter 5 -4 14-Nov-16 18-Nov-16 -68 -10 0% 82180 QUAN Training Mag Flow Meter 5 203 14-Nov-16 18-Nov-16 -68 -10 0% 83180 QUAN Training Thermal Flow Meter 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 84180 QUAN Training Ultrasonic CC Flow Meter 5 194 14-Nov-16 18-Nov-16 -68 -10 0% 85180 QUAN Training Ultrasonic OC Flow Meter 5 194 14-Nov-16 18-Nov-16 -68 -10 0% 86180 QUAN Training Venturi Flow Tube 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 88180 QUAN Training Thermal Flow Switch 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 89180 QUAN Training Ultrasound LevelTransmitter 5 196 14-Nov-16 18-Nov-16 -68 -10 0% 90180 QUAN Training Ultrasound MPLevelTransmitter 5 196 14-Nov-16 18-Nov-16 -68 -10 0% J J A S D J A J J A S O J F A J Submit MCC's 6626 O&M Submit Girder Bridge Cranes O&M Submit Girder Bridge Cranes Training Manuals Submit Monorail Hoist O&M Submit Monorail Hoist Training Manuals Submit Jib Crane O&M Submit Jib Crane Training Manuals Submit Transfer Switch O&M Submit Transfer Switch Training Manuals Submit Substation O&M Submit Substation Training Manuals Submit MCC's 6631 & 6634 O&M Submit MCC's 6631 & 6634 Training Manuals Submit MCC's 6674 O&M Submit MCC's 6674 Training Manuals Submit MCC's 6626 Training Manuals Submit MCC's 6921&6922 O&M Submit MCC's 6921&6922 Training Manuals Submit MCC's 6961 O&M Submit MCC's 6961 Training Manuals Submit MCC's 6963&6995 O&M Submit MCC's 6963&6995 Training Manuals Submit MCC's 6962 O&M Submit MCC's 6962 Training Manuals Submit MCC's 6925&6926 O&M Submit MCC's 6925&6926 Training Manuals Submit MCC's 6993 O&M Submit MCC's 6993 Training Manuals Submit & Approve Polymer System Approve Monorail Hoist O&M Approve Monorail Hoist Training Manuals Submit Polymer System O&M Submit Polymer System Training Manual Fabricate Polymer System 16-Dec-16, Training Training Course Bubble Aeration Training SS system Training Density Meter Training Mag Flow Meter Training Thermal Flow Meter Training Ultrasonic CC Flow Meter Training Ultrasonic OC Flow Meter Training Venturi Flow Tube Training Thermal Flow Switch Training Ultrasound LevelTransmitter Training Ultrasound MPLevelTransmitter Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 7 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 8. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete 91140 QUAN Training Float Switch (tilt) 5 205 14-Nov-16 18-Nov-16 -68 -10 0% 92180 QUAN Training Pressure Transmitter 5 205 14-Nov-16 18-Nov-16 -68 -10 0% 93180 QUAN Training Diff Pressure Transmitter 5 205 14-Nov-16 18-Nov-16 -68 -10 0% 96180 QUAN Training Pressure Switch 5 205 14-Nov-16 18-Nov-16 -68 -10 0% 98180 QUAN Training Temp. Transmitter/RTD 5 205 14-Nov-16 18-Nov-16 -68 -10 0% 100180 QUAN Training Temp. Switch 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 103180 QUAN Training Motion Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 104180 QUAN Training Smoke Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 105180 QUAN Training Heat Detector 5 63 14-Nov-16 18-Nov-16 -68 -10 0% 63240 GOW Training Polymer system 5 189 12-Dec-16 16-Dec-16 -68 -9 0% Construction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and FabricationConstruction Submittals, Approvals and Fabrication 47520 WALSH Procure RESILIENT FLOORING 0 390 13-Nov-16 13-Nov-16 -41 -13 0% 41200 LAND SUBMIT TOPSOIL AND FINISH GRADING 1 311 13-Nov-16 13-Nov-16 -98 -13 0% 41300 LAND SUBMIT SODDING 1 311 13-Nov-16 13-Nov-16 -98 -13 0% 41400 LAND SUBMIT PLANTING OF TREES, SHRUBS AND GROUND COVERS 1 246 13-Nov-16 13-Nov-16 -98 -13 0% 47200 WALSH SUBMIT GYPSUM BOARD 1 201 13-Nov-16 13-Nov-16 -98 -13 0% 47400 WALSH Submit ACOUSTICAL CEILINGS 1 237 13-Nov-16 13-Nov-16 -98 -13 0% 48200 WALSH Submit EXTERIOR WALL LOUVERS 1 -11 13-Nov-16 13-Nov-16 -98 -13 0% 48300 WALSH Submit EQUIPMENT LOUVERED PENTHOUSE 1 315 13-Nov-16 13-Nov-16 -98 -13 0% 41210 OWNER APPROVE TOPSOIL AND FINISH GRADING 14 311 14-Nov-16 27-Nov-16 -98 -13 0% 41310 OWNER APPROVE SODDING 14 311 14-Nov-16 27-Nov-16 -98 -13 0% 41410 OWNER APPROVE PLANTING OF TREES, SHRUBS AND GROUND COVERS 14 246 14-Nov-16 27-Nov-16 -98 -13 0% 47210 OWNER Approve GYPSUM BOARD 14 201 14-Nov-16 27-Nov-16 -98 -13 0% 47410 OWNER Approve ACOUSTICAL CEILINGS 14 237 14-Nov-16 27-Nov-16 -98 -13 0% 48210 OWNER Approve EXTERIOR WALL LOUVERS 14 -11 14-Nov-16 27-Nov-16 -98 -13 0% 48310 OWNER Approve EQUIPMENT LOUVERED PENTHOUSE 14 315 14-Nov-16 27-Nov-16 -98 -13 0% 47320 WALSH Procure TILES 60 252 13-Nov-16 11-Jan-17 -98 -13 0% 47720 WALSH Procure Chem RESISTANT COATINGS 60 274 13-Nov-16 11-Jan-17 -98 -13 0% 48020 WALSH Procure METAL TOILET PARTITIONS 60 266 13-Nov-16 11-Jan-17 -98 -13 0% 48120 WALSH Procure METAL LOCKERS 60 266 13-Nov-16 11-Jan-17 -98 -13 0% 48420 WALSH Procure WASHROOM ACCESSORIES 60 274 13-Nov-16 11-Jan-17 -98 -13 0% 47220 WALSH Procure GYPSUM BOARD 60 201 28-Nov-16 26-Jan-17 -98 -13 0% 47420 WALSH Procure ACOUSTICAL CEILINGS 60 237 28-Nov-16 26-Jan-17 -98 -13 0% 48220 WALSH Procure EXTERIOR WALL LOUVERS 60 -11 28-Nov-16 26-Jan-17 -98 -13 0% 48320 WALSH Procure EQUIPMENT LOUVERED PENTHOUSE 60 315 28-Nov-16 26-Jan-17 -98 -13 0% MobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilizationMobilization A21170 WALSH Submittals 114 275 03-Sep-13 A 08-Mar-17 -106 -14 90.17% A21165 WALSH Management of Project 222 168 03-Sep-13 A 23-Jun-17 272 -13 80.01% A21220 QUAN Quantech Site Mangement 266 75 18-Jul-16 A 05-Aug-17 -98 -13 2.16% CommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommissionCommission BALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANTBALANCE OF PLANT Mechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower RmMechanical Rm 6/Old Blower Rm S1040 Complete SCADA for COM-5100 (Mech Rm 6) 75 143 16-Feb-16 A 08-Mar-17 -68 -10 59.68% Primary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary GalleryPrimary Gallery Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9Gallery 9 58170 Loop Check Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16* 14-Nov-16 -67 0 0% J J A S D J A J J A S O J F A J Training Float Switch (tilt) Training Pressure Transmitter Training Diff Pressure Transmitter Training Pressure Switch Training Temp. Transmitter/RTD Training Temp. Switch Training Motion Detector Training Smoke Detector Training Heat Detector Training Polymer system 26-Jan-17, Construction Submittals, Approvals and Fab Procure RESILIENT FLOORING SUBMIT TOPSOIL AND FINISH GRADING SUBMIT SODDING SUBMIT PLANTING OF TREES, SHRUBS AND GROUND SUBMIT GYPSUM BOARD Submit ACOUSTICAL CEILINGS Submit EXTERIOR WALL LOUVERS Submit EQUIPMENT LOUVERED PENTHOUSE APPROVE TOPSOIL AND FINISH GRADING APPROVE SODDING APPROVE PLANTING OF TREES, SHRUBS AND GROU Approve GYPSUM BOARD Approve ACOUSTICAL CEILINGS Approve EXTERIOR WALL LOUVERS Approve EQUIPMENT LOUVERED PENTHOUSE Procure TILES Procure Chem RESISTANT COATINGS Procure METAL TOILET PARTITIONS Procure METAL LOCKERS Procure WASHROOM ACCESSORIES Procure GYPSUM BOARD Procure ACOUSTICAL CEILINGS Procure EXTERIOR WALL LOUVERS Procure EQUIPMENT LOUVERED PENTHOUSE 05-Aug-17, Mobilization Submittals Management of Project Quantech Site Mangement 08-Mar-17, Commission 08-Mar-17, BALANCE OF PLANT 08-Mar-17, Mechanical Rm 6/Old Blower Rm Complete SCADA for COM-5100 (Mech Rm 6) 19-Jan-17, Primary Gallery 19-Jan-17, Gallery 9 Loop Check Submersible Cent. Pump (P-0001&2&5130-31 Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 8 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.
  • 9. Activity ID Longest Path 213060-RESPActivity Name RD Total Float Start Finish August 7 - Baseline Variance Weekly Variance % Complete 58180 Calibrate Submersible Cent. Pump Instrumentation 1 -79 14-Nov-16 14-Nov-16 -66 0 0% 58190 Equipment Checkout Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16 14-Nov-16 -65 0 0% 58200 Functional Test Submersible Cent. Pump (P-0001&2&5130-31) 1 -79 14-Nov-16 14-Nov-16 -63 0 0% 13002660 Commission & Return to Service PT9 14 -78 14-Nov-16 01-Dec-16 -26 0 0% 75220 Performance Test Seal Water Pump (P-4520) 14 193 14-Nov-16 01-Dec-16 -72 0 0% 58210 Performance Test Submersible Cent. Pump (P-0001&2&5130-31) 14 -79 15-Nov-16 02-Dec-16 -63 0 0% 13002670 COMPLETE PRIMARY GALERY PHASE 1 0 -79 02-Dec-16 -27 0 0% 12003105 GOW Commission Seal Water Pumps 5 44 09-Dec-16 15-Dec-16 -59 -13 0% 59240 Performance Test Scum Pump (P2501-2) 14 193 02-Dec-16 21-Dec-16 -64 0 0% 120020 Approve Jib Crane O&M 28 148 14-Nov-16 21-Dec-16 -68 -10 0% 120030 Approve Jib Crane Training Manuals 28 148 14-Nov-16 21-Dec-16 -40 -10 0% 120040 Order Jib Crane 1 148 22-Dec-16 22-Dec-16 -40 -10 0% 21011850 WALSH Performance Test RI HD Cent. Pump (P-3401-3602&0160-70) 14 288 22-Dec-16 04-Jan-17 -86 0 0% 120050 Fabricate Jib Crane 29 223 22-Dec-16 19-Jan-17 -43 0 0% J J A S D J A J J A S O J F A J Calibrate Submersible Cent. Pump Instrumentation Equipment Checkout Submersible Cent. Pump (P-0001&2& Functional Test Submersible Cent. Pump (P-0001&2&5130 Commission & Return to Service PT9 Performance Test Seal Water Pump (P-4520) Performance Test Submersible Cent. Pump (P-0001&2&5 COMPLETE PRIMARY GALERY PHASE 1 Commission Seal Water Pumps Performance Test Scum Pump (P2501-2) Approve Jib Crane O&M Approve Jib Crane Training Manuals Order Jib Crane Performance Test RI HD Cent. Pump (P-3401-3602&01 Fabricate Jib Crane Actual Work Remaining Work Critical Remaining Work Milestone Summary ASHBRIDGES BAY TREATMENT PLANT - P BUILDING AND ODOUR CONTROL Project 12 Week Look Ahead - 1 Week Spotlight Date Date: 13-Nov-16 page 9 of 9 Layout: I.S 12 WLA 20161115 Filters: TASK filters: Activity Not Complete, I.S 6 Week Look Ahead.