1. SHERAZ AHMED
Allama Iqbal Town Basti Mian
Sahib Manthar Road, Sadiq Abad
Distt: Rahim Yar khan
Cell # :+923067613511
:+923417086927
Email: sheraz_ahmed0571@yahoo.com
Email: sheraz.ahmed571@gmail.com
Professional Career Objective:
• A highly motivated Operation professional with skill in strategic emergency handling and
problem deification is looking for a post of Utilities Operator.
Personal Profile:
Father’s Name MUHAMMAD AMIN
Date of birth 23-11-1989
CNIC No. 31304-7857643-1
Nationality Pakistani
Religion Islam
Marital Status Marriad
Permanent Address Allama Iqbal Town Basti Mian Sahib Manthar Road
Sadiq Abad. Dist. Rahim Yar Khan.
Academic Qualification:
Degree Division Passing Year
Matriculation 1st
Div 2005
F.Sc (Non Medical) 1st
Div 2007
Technical Qualification
Two years apprenticeship as utility operator from Fauji Fertilizer Company Ltd. at Base Unit
Goth Machhi Sadiq Abad, Currently I am working on Utility Plant in Fauji Fertilizer Company
Ltd Goth Machhi, Pakistan facilitated with DCS (CS-3000) (Certified ISO-9001:2008, OHSAS-
18001:2007 & ISO-14001:2004) Since 31 Oct. 2008 to present.
Professional Experience Detail
• GAS TURBINE
• VERY HIGH BOILER
• BOILER FEED WATER NETWORK
• DEAERATOR
• COOLING TOWER
• CHILLERS
• LET DOWN STATIONS
• CONDENSATE POLISHING (DEMIN)
• N2 GENERATION PLANT (CRYOGENIC PROCESS)
2. GAS TURBINES (Two gas turbines of General Electric) MS-5001
Cycle Combined
Generator Rating 31375 KVA of Each
Gas Turbine Power 34000 HP of Each (Useful Power)
Control Mark-V and Mark-2 (Droop AND ISO for each Turbine)
Fuel Natural Gas and Diesel
Emergency Shut Down ELMS and Snamprogetty Shut Down
Chemical Used(Water Treatment) Nalcool-2000
2. Very High Pressure Steam Boiler of Combustion Engineering
Type D. Type Water Tube
Pressure 105 Kg/Cm²
Temperature 510 ºC
Capacity 77 Ton/Hr
Firing Tangential
Water Circulation Thermosyphoning
Draft Forced
Fuel Natural Gas, Syn Gas and Purge Gas
No. Of Drums Two (Upper Steam Drum) & (Lower Mud Drum)
No. Of Burners Four
Super Heaters Two Primary & Secondary
De-Superheater Inner Lined
Igniters Four Electrically Ignited With Step Up Transformer (10000 V)
Control Auto & Manual
Combustion air is supplied by a forced draft fan driven either by Steam Turbine or Motor.
Normally Steam Turbine is in service and motor on Standby.
3. Boiler Feed Water System
No Of Systems Two (High Pressure) & (Medium Pressure)
No. Of Pumps 06 (Three for High Pressure & Three for Medium Pressure)
Pressure Of HP-BFW 160 Kg/Cm² with Temperature 117 ºC
Pressure Of MP-BFW 60 Kg/Cm² with Temperature 117 ºC
Water Deminerallized Water
Usage Of Total Feed
Water
490 ~ 510 M³/Hr
Stages Of Each Pump 08
Type Centrifugal
Driven One (High Pressure Pump) with steam Turbine & the other two with
Motors. Normally steam Turbine driven remains in Operation and Motor
driven are on Auto Standby. For Medium Pressure One is driven with
Steam Turbine and the other two with Motors. Normally in Medium
Pressure One Steam Turbine driven & one Motor driven remains in
Operation and third one on Auto Standby.
De-Aerator Pressurized (Spray & Tray Type) With Chemical and Mechanical De-
Aeration
De-Aeration Mechanical and Chemical
3. 4. Steam Let Down Stations
No. of Stations 03 With The Capacity of 13/86/32 Ton/Hr Respectively
Purpose Two for let down of Very High Pressure Steam (105 Kg/Cm² & 510
ºC) into High pressure Steam (39 Kg/Cm² & 375 ºC) and One for from
High Pressure Steam (39 Kg/Cm²& 375 ºC) into Low Pressure Steam
(2.5 kg/Cm² & 180 ºC).
• A condensate recovery system is also provided.
5. Cooling Tower
Vendor Lilly Hoffman
Type Cross Flow Induced Draft with 09 Cells
No. Of Cooling Water
Circulating Pumps
05.( Four driven by Motors and One with Steam Turbine) Absorbed
Power 1000 KW each
Motor Rating Two of 1.3 MW and Other Two of 1.1 MW
Steam Turbine Rating 1500 HP
Steam Rating 39 Kg/Cm² and 375 ºC
Cooling Water Circulation
Rate
32000 M³/Hr and 8000 M3/Hr Flow Of each Disch Press. 4.5 Kg/cm2
No. Of Cooling Water
Filters
04 (Automatic Valve less Gravity Sand Filters)
pH control of Cooling
Water
Through Ejector Acid Dosing and PD. Diaphragm Pumps
Cooling Water Treatment Buckman Laboratories (Pvt Ltd) BULAB Chemicals and Sulfuric
Acid
Corrosion, Scaling and
Fouling Control
Phosphate System and Cathodic Protection
6. CHILLERS
I have worked on compression and absorption chillers using freon-12/22 and Li-bromide as
refrigerant respectively
Total chillers 08
Total Compression Chillers (PD compression)= 03
Total Absorption chillers = 04
7. N2 GENERATION PLANT (CRYOGENIC PROCESS)
Design Capacity 1340 NMC/Hr
Design pressure 8.5 Kg/Cm²
Design Temp. 40 ºC
Skill Improvement Courses
Following Skill Improvement Courses attended while working with Fauji Fertilizer Company
Limited Goth Machhi.
Centrifugal Pumps
Centrifugal Compressors
4. Positive displacement Pumps
Positive displacement Compressors
Cooling Water Treatment
Safety in Chemical Process Industry
Fire Fighting (Wet Drill)
Work Permit Procedure